1. Weight approx TSR 301S Liquid Crystal Display 4 Digits 1 10th of a degree increments 89 6 F to 109 4 F 32 0 C to 43 0 C Oral Axillary and Rectal F or C 0 2 F between 89 6 F and 109 4 F 0 1 C between 32 0 C and 43 0 C gt 99 5 F 37 5 C eight sets of three quick beeps will sound Four quick beeps will sound TSP 001 SG3 Alkaline Approximately 200 hours Approximately after 10 minutes Last temperature recall Yes 41 0 F to 104 0 F 5 0 C to 40 0 C 10 to 80 RH 14 0 F to 140 0 F 10 0 C to 60 0 C 10 to 80 RH 5 2 x 0 83 x 0 43 0 47 oz including battery Specifications are subject to change without notice Manufacturer s One Year Limited Warranty Manufacturer will at its option repair or replace your thermometer with the same or comparable model for a period of one year from the date o purchase in the event of a defect in materials or workmanship The warranty only extends to the original retail purchaser Purchase receip or other proof of original purchase is required before warranty performance This warranty extends solely to failures due to defects in materials or workmanship occurring during normal use It does not cover norma wear of the product This warranty is void if the housing product has been removed if the manufacturer s label logo or serial number have been removed or if the product fails to function properly as a result o accident misuse abu
2. HEALTHY LIVIN G 30 Second Digital Thermometer with Accu Fast Technology Thank you for purchasing Samsung Healthy Living 30 Second Digital Thermometer with beeper memory and high temperature alarm Before using your new thermometer please read and follow instructions to insure most accurate body temperature readings Information herein and product are not meant to be a substitute for the advice provided by a medical professional DIGITAL DISPLAY WINDOW ON OFF BUTTON Accu Fast PROBE TIP BATTERY COVER 1 BODY TEMPERATURE Normal Body Temperature fluctuates during the course of a day and depends on location of temperature reading The generally accepted normal body temperature is 98 6 F 37 0 C for oral An axillary or underarm reading is usually is 1 0 F 0 5 C lower 97 6 F 36 4 C and a rectal temperature is usually 1 0 F higher 0 5 C 99 6 F 37 5 C Body temperature readings tend to be lowest in the morning hours from 2 a m to 4 a m while your body is resting and is highest during late afternoon hours from 4 p m because your body has been active throughout the day How to know your Normal Body Temperature The best way to find out your normal body temperature is to measure yourself when you are feeling well Record your readings twice a day early morning and late afternoon The average of the two readings is your normal body temperature Any deviation from this may indicate an ill
3. er 10 minutes to preserve battery life TAKING A RECTAL TEMPERATURE Approximate reading time 30 seconds NOTE Rectal temperatures are the most accurate method for infants and small children Otherwise this method should only be used when it is difficult to take an oral or axillary measurement Rectal temperatures are generally 1 0 F 0 5 C higher than oral readings For hygienic reasons once thermometer is used rectally do not use orally 1 Place a new or clean and undamaged probe cover carefully over the thermometer tip 2 Have your child lie stomach down on your lap 3 Apply a water soluble lubricant to the tip of the thermometer and around rectum 4 Hold your child still and gently insert the probe a maximum of 1 inch into the rectum If child is less than 6 months old gently inserta maximum of 1 4 to 1 2 inch into the rectum 5 When peak temperature is reached the F C will stop flashing and four quick beeps will sound 6 To turn the unit off press the On Off button otherwise the unit will automatically shut off approximately after 10 minutes to preserve battery life SPECIFICATIONS Model Number Display Display Resolution Measurement Range Measurement Location Temperature Scales Accuracy High Temperature Alarm Completed Measurement Probe Covers Battery Type Battery Life Automatic Shut off Memory Waterproof Ambient Range Storage Range Dimensions approx
4. ion or Comments 1 800 261 0130 info SamsungHealthcare com www SamsungHealthcare com Printed in Taiwan
5. ness and you should consult a medical professional HIGH TEMPERATURE ALARM This thermometer has a built in alarm to warn user of higher than normal temperature If reading exceeds 99 5 F 37 5 C eight sets of three quick beeps will sound 2 CLEANING INSTRUCTIONS amp USING DISPOSABLE PROBE COVERS Prior to each use clean the thermometer with a soft cloth moistened with rubbing alcohol 70 isopropyl alcohol diluted with warm water OR wash with cold soapy water An intact unit can be submersed in 50 water and 50 alcohol however do not soak for an extended period of time Be sure to dry thermometer thoroughly using soft cloth To make temperature taking more hygienic and to help prevent cross contamination itis recommended to use Samsung Disposable Probe Covers model TSP 001 each time temperature is taken BATTERY When the 188 8 symbol is continuously flashing the battery needs to be replaced with an SG3 silver oxide type To replace battery 1 Slide battery cap away from unit 2 Remove the battery using a small Phillips head or jeweler s screwdriver and insert new battery with the positive side facing up 3 Carefully slide battery cap back into its place making sure the cap is securely fit to protect battery from moisture Caution Please properly dispose of the old battery away from small children and heat INSTRUCTIONS FOR USE 1 Clean and properly disinfect the thermome
6. ometer tip 2 Place the probe tip under the tongue as near as possible to the heat pocket The diagram below also shows the temperature variables by not placing the tip in the heat pocket areas Hold the thermometer still in the same spot and mouth should remain closed for most accurate reading 3 The current temperature is shown and the F C will continue to flash during the reading 4 When peak temperature is reached the F C will stop a flashing and four quick beeps will sound 5 To turn the unit off press the On Off button otherwise the unit will automatically shut off after approximately 10 minutes to preserve battery life TAKING AN AXILLARY TEMPERATURE UNDERARM Approximate reading time 50 seconds NOTE Axillary temperatures are generally 1 0 F 0 5 C lower than oral readings 1 Wipe underarm area with a dry towel 2 Place a new or clean and undamaged probe cover carefully over the thermometer tip 3 Place the probe tip under the arm so that the tip is touching the skin with the thermometer perpendicular vertical to the body 4 Position arm across the chest so the probe tip is well covered by the arm This insures the ambient temperature does not affect the probe 5 When peak temperature is reached the F C will stop flashing and four quick beeps will sound 6 To turn the unit off press the On Off button otherwise the unit will automatically shut off approximately aft
7. se neglect mishandling misapplication defective batteries faulty installation set up adjustments improper maintenance alteration maladjustments of control modification power surges commercial use of product service by anyone other than an authorized service center or acts beyond the manufacturer s control This warranty and remedy provided herein are exclusive and in lieu of all other express and implied warranties and unless stated herein any statements or representations made by any other person or entity are void Neither the manufacturer distributor nor their affiliates shall be liable for loss inconvenience injury or damage including direct special incidental or consequential damages resulting from the use improper use failure to heed any warning disclaimer or instruction or inability to use this product whether arising out of breach of this warranty or any other legal theory All express and implied warranties including the warranties of merchantibility are limited to the applicable warranty period set forth above Manufacturer and distributor assume no responsibility for injuries damages or penalties incurred or suffered resulting from the use of this product in an improper manner or location other than for which it is intended or from failure to heed any warning disclaimer or instruction 9 HEALTHY LIVIN G SAMSUNG AMERICA INC 105 Challenger Road 6th FI Ridgefield Park NJ 07660 Quest
8. ter according to the instructions provided 2 Place a new or clean and undamaged probe cover carefully over the thermometer tip 3 Select oral axillary or rectal as your measurement site 4 Press On Off button to activate thermometer The digital display will show the following and the thermometer will beep This is the LCD display test which insures gq oF all parts of the display are functioning l m ME properly Continue to hold the button Ky F switch down over 2 seconds the display will flash alternatively C F icons Release button on preferable mode of read out 1 F This display shows the last temperature L Qa M reading after C F selection After the display of the last measured o reading the unit will perform a self 77 n F calibration standard temperature and display 97 7 F for about one second a es a The Lo with the flashing C F indicates L out the thermometer is ready to take a temperature reaging If ERR is displayed a malfunction has been detected and thermometer will need to be replaced 4 TAKING AN ORAL TEMPERATURE Approximate reading time 30 seconds NOTE Relax and wait approximately 5 minutes with your mouth closed before taking a reading if you ve just consumed any hot or cold beverages exercised or smoked This will reduce chances of possible high or low temperature readings 1 Place a new or clean and undamaged probe cover carefully over the therm