1. fluffy cloth It is very important that the coals and the coal bed components are laid as shown no extra coals or material may be used If any of the items become lost or damaged replacements must be obtained before further use of the appliance Relaying the Coal Bed Fit the coal support shelf and simulated coal front Fig 2 Referring to figures 2 3 and 4 lay the coals as follows L Place 4 large round coals between the simulated coal front and the support shelf Fig 3 2 Place 3 round coals between the gaps in the front row Fig 3 3 Place the 5 small round coals between the gaps formed in the coals laid in 1 amp 2 above Fig 4 Cleaning the Front of the Appliance The fire must be turned off and allowed to cool The paintwork should be cleaned with a soft cloth or soapy water the brass trim has a clear lacquer coating to preserve the polished finish DO NOT USE ABRASIVES OR METAL POLISH Spares and Service For spares and service contact your local supplier installer or direct to the manufacturer stating that the appliance is a Slimline Turbo and quote the serial number from the data label located on the fascia panel If the fire fails to light and no spark is heard in the first instance a replacement battery should be obtained and fitted To replace battery remove the heat shield protecting the unit and slide battery forward Ensure ve connection is uppermost on the replacement and slide into the connector receptacles Advan
2. situated on the right hand top corner of the surround and is controlled by a fully modulating thermoselector thermostat Once the desired room temperature that has been selected by the control has been reached the gas input to the appliance is automatically reduced to low The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required This appliance is intended for decorative purposes the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion An aerated single port steel burner is used running parallel across the front of the fire A battery operated spark generator is used to ignite an Oxy pilot sensor the Oxy pilot or O D S will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of which are removable for cleaning purposes when required It is important when relaying the coal bed and coals to follow the instructions correctly There are special requirements for installations in timber framed dwellings relating to minimum clearances between any part of the fire or the flue and combustible materials These are stipulated in the Building Regulations for the shielding of flue pipes for class II appliances BS5871 Pt 3 1991 A suitable
3. the fret of 50 sq cms and 60 sq cms in the front Additional purpose built ventilation is not required for this appliance in GB only for Ireland IE ventilation is required with a minimal cross sectional area of 100 sq cms and should be checked regularly to ensure that it is free from obstruction It must be fitted in accordance with the rules in force Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and embossed materials may be become discoloured by convected heat Soft furnishings must be kept clear from the radiant heat of the fire and from impinging the hearth area The hearth must not be covered by any combustible materials such as carpets etc This appliance is fitted with an Oxy pilot which in the event of the flue being blocked or hazardous conditions exists which causes the appliance to spill products of combustion will shut OFF the gas supply If when the fire is relit the sequence is repeated the appliance must be turned OFF and not used until expert advice has been obtained In very strong wind conditions the fan may be heard to increase in speed this is not detrimental to the operation of the appliance as the increase is to extract those products that may be prevented leaving the flue by the wind Exceptionally the fire may shut down and require relighting due to a sustained strong gust The curing effect of heating the coals will cause an initial odour which although
4. 0102 095 50281 SLIMLINE TURBO Flame System 5 USERS INSTRUCTIONS THIS CAT by APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB amp IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION The Slimline Turbo is a decorative gas fire which incorporates a horizontal flue that has been designed specifically to be used in applications that do not have a conventional chimney or flue but can be located so that the flue can terminate on an outside wall The fire is switched ON and OFF from a push button situated on the right hand top corner of the surround and is controlled by a fully modulating thermoselector thermostat Once the desired room temperature that has been selected by the control has been reached the gas input to the appliance is automatically reduced to low The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required This appliance is intended for decorative purposes the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion An aerated single port steel burner is used running parallel across the front of the fire A Flame Supervision Device FSD is fitted to ensure that should the pilot flame be extinguished for any reason including turning off the appliance the gas supply to the burner is cut off u
5. 50mm from any part of the fan housing and screwed to the wall using suitable plastic plugs and screws GAS CONNECTION Complete the gas connection to the inlet elbow pressure test point When the burner has been removed for any reason ensure care is taken to fit the push button assembly correctly and ensure that the electrical connections are in place and that the solenoid is connected The fibre support shelf the fibre back and the canopy can now be refitted It is suggested that the installation is completed and tested for operation prior to fitting the other fibre components Re fit the surround and brass trim the brass trim is retained with magnets Tum on the gas supply at the meter and purge the air to the appliance To check the gas pressure turn off the gas supply at the isolating cock remove the hexagon headed screw and connect a manometer to the pressure test point Fit the battery make the electrical connection as described earlier and switch on the supply to the appliance Turn on the gas and ignite the fire allow to heat up and check that the gas pressure is 20mbar 1 mbar any appreciable drop may indicate restrictions through the pipework up to the fire If other gas appliances are fed from the same supply check that the input pressure remains constant with those other appliances operating The pressure test point may also be used to check for leakage of the joints to the appliance On completion of the pressure test repla
6. AGE CHECK Light the appliance and set to the maximum thermostat position locate the front and fret in position and leave to warm up for 5 minutes Check for satisfactory clearance of combustion products by positioning a lighted smoke match 20mm down from edge of canopy 80mm from either side and 45mm back from the front edge All the smoke must be drawn into the flue see Fig 16 If spillage occurs allow a further 10 minutes The test should be carried out with all the doors and windows closed If an extractor fan is situated in the room the test should be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors in that room opened and the extractor fan running If an open flued appliance is situated in an adjoining room the operation of that appliance should be checked with this appliance operating If either the appliance spills or causes another appliance to spill check the operation of the flow sense switch Demonstrate the lighting and extinguishing procedures to the user ADVISE THAT The curing effect of heating the coals will cause an initial odour which although not harmful may require additional ventilation until the odour has disappeared Any debris or soot is cleaned from the appliance A vacuum cleaner can be used carefully The appliance must be serviced annually by a competent person in accordance with these instructions at this time the appliance should
7. S OYIN O1 NOLLO3NNOO NOLLISOd ON 3HL O1 9NHO MS ee ee LON TULS HOUMS 3uNSsaud Auallvg A HOUMS JYNSEJYd MuWdS ON MEX TYVION saian ga 31Vi3dO 31vu3dO OL 390S83uUd o TINH 34310 LNAIDIS4ANSNI NOLUSOd ON OL 13638 LON TILE HOLMS 3YuNss3yd ONY SYNIN 39Y320 1d WO 380 GNY J3JdINYO 93H92 3ZI0W3N3 THM JAWA GIONS 108 H2JJMS 3unSS3ud NOULISOd ON JHL OL ONIHOJIMS JHL G3ivH3dO SVH JANSSIUd TVLUN38343IG LON HOUMS JYNSSJYd N3HM 033dS MOT Ot SSHOUMS NY 3 ISN SnOIA3Ud u314V NOLLISOd ON JHL OL ONLLL3S 3MN JON HOUMS 3JYNSESJYd 4 amp ONINNDY sa was HOJJAXSOWODIW O4 NOLLOINNOD TONLNOD 33O NO 3tYY3JdO SINVWidd OL NO O3HOLIMS YIJMOd SNIV 1S1H53H2 ONICNIS L0nU3 OFUNL INNWNS Description Crosslee Part No GC No Spark Generator 42545 Gas Protector Valve 42541 Thermoselector 42540 Control Knob 40232 Thermo Electric Micro 42542 Switch Spark Ignition Micro 42543 Switch Fan Micro Switch Assembly 42810 Oxy Pilot Assembly 42282 Main Injector 41200 Fibre Back Panel 42830 Front Simulated Coal 42769 Coal Supports LH amp RH 42836 Set of Coals 42658 Control Box 42800 Pressure Switch 42511 Fan Two Speed 41841 Solenoid Valve c w Coil 42418 Brass Plated Trim 42548 Canopy 42625 Outer Frame 42690 14
8. and an electrical supply close to the proposed siting ideally any new feed should be to the left of the appliance See Fig 3 When it is necessary to route an electrical supply across the back of the appliance it must be channelled into the wall at hearth height or lower The appliance is designed to be installed against a non combustible wall using a surround with a 76mm rebate A timber frame fixing kit is available for the flue in timber framed buildings The fire must always be fitted with a hearth and the minimum sizes are as shown in Fig 2 and listed in the following paragraph The minimum fire resistance specification for the hearth and back panel is Class O 100 C The minimum thickness of insulation beneath the appliance for combustible floors is 18mm therefore if l The floor is a solid non combustible floor a minimum hearth thickness of 12 mm with a perimeter of 50mm is required 2 The floor is a timber or suspended floor a minimum thickness of 18mm with a perimeter of 50mm is required When the required height for the hearth has been established and the hearth under the fire is laid in position place the appliance in the proposed site taking care not to damage the wiring harness protruding from the rear of the appliance mark around the edges of the appliance and the positions of the fixing holes See Fig 3 Access to the fixing holes is achieved by removal of the canopy the fibre back and the fibre support plate The c
9. anopy is held in position by two screws located as shown in Fig 18 the fibre back is held by the canopy Remove the appliance and find the centre of the outline drawn Measure up from the proposed hearth height 476mm which is the centre line for drilling a 127mm diameter hole with a core drill Alternatively use 100mm and 25mm diameter holes as shown in fig 4 drill through the wall If a combustible skirting board is fitted it will have to be cut away to give 75mm minimum clearance either side of the hot box or to the width of the hearth or surround as applicable To assemble the flue to the rear of the hot box use the 6 x No 8 self tap screws and the ceramic gasket supplied pass the flue through the flue mounting plate feed the wiring loom through the ceramic fibre gasket and the flue mounting plate rotate the flue tube so that the flat section of the flange lays horizontal and screw into position as shown in fig 5 At this stage it is advisable to attach a piece of wire to the end of the wiring loom to pull through the wall and to keep the loom taut while feeding through the conduit A further rock wool gasket is provided to furnish a seal around the drilled flue opening to prevent draughts Note It is advisable to seal around the flue pipe outlet on the external wall to reduce draught A minimal total depth of the installation is required from the surround back panel see fig 6 For surrounds having a greater depth than 76mm insulating
10. be re checked for spillage in accordance with the method detailed in these instructions T3 The thermoselector is positioned so that the room temperature stabilises at the customer s comfort level and is not used as a variable heat control The appliance is fitted with an Oxy pilot to prevent the continued operation in the event of spillage occurring If the fire shuts OFF repeatedly the appliance must be turned off and not used until an expert is consulted It is advisable to run the fan periodically when the fire is not in use summer time to ensure that the fan and associated components are exercised and therefore are serviceable when required This may be achieved by releasing the on button before the gas has lit and allowing only the fan to run In severe winds it 1s possible that the flow sense switch will close causing the fan speed to increase Exceptionally it may close down the fire which will necessitate initiating a re lighting sequence Complete the registration section on the enclosed warranty form Advise that any component part of this appliance is guaranteed against defective workmanship or faulty materials for a period of twelve months from the date of purchase Any such part will be replaced free of charge on receipt of the purchaser s address at the cost of postage only provided that a It is accompanied by the registration section cut out of the booklet together with the original purchase receipt which will be re
11. ce the pressure test point screw and check for leakage Note The complete installation should be tested for Gas soundness Any fire surround and back panel fitted as part of the installation should be installed in accordance with the manufacturers instructions CHECKING OPERATION OF FIRE Depress the control button situated on the top right corner of the surround Check by listening to the fan speed that it starts on high and reduces to slow and that the electrode is sparking between the tip of the thermocouple and the electrode Continue until a pilot ignition is established hold for a further 10 15 seconds release and the main burner will light Rotate the thermoselector knob and view the flame varies between low and high Lift the control button to the OFF position and ensure that both the pilot and main burner extinguish and the fan stops To check the operation of the flow sense switch refer to paragraph ix in the servicing section LAYING THE COAL BED Fit the coal support shelf and simulated coal front Fig 12 Referring to figures 12 13 14 and 15 lay the coals as follows 1 Place 3 medium round between the simulated coal front and the support shelf with 1 triangular coal placed on either side of this row Fig 13 2 Place 2 medium round between the centre gaps of the coal support shelf with 1 medium small coal placed at each side Fig 14 3 Place the 8 small between the gaps formed in the previous coal layout Fig 15 SPILL
12. ck for access to the insulation quilt cut the quilt and inner timber sheathing to the same size as the rectangle Mark and drill the outer wall as shown in fig 4 When fitting appliances with circular flues into existing timber framed houses a drip collar should be used One can be constructed by wrappimg a wire of material that will not promote corrosion tightly around the assembly twisting the ends together underneath the duct See fig 7 The heatshield supplied in the timber frame kit 1s manufactured in two pieces an inner and outer skin with approximately 25 mm air gap between Measure the total thickness of the inner wall the heatshield must be trimmed down to the depth of the inner wall and should not project more than 10 mm into the cavity Remove the two screws securing the two skins together to enable the two halves to be trimmed with a pair of tinsnips or hacksaw and replace the two halves together Screw the heatshield to the wall as shown in fig 7 using cavity fixing plugs if necessary use non combustible material as fig 8 as required and locate the closure plate see fig 6A ES GAS SUPPLY BEFORE COMMENCING WORK TURN OFF ANY APPLIANCES THAT ARE FED BY THE METER AND ISOLATE THE GAS SUPPLY BY TURNING OFF AT THE METER The gas connection to this appliance is made with 8mm o d rigid or semi rigid tube to a pressure test elbow situated on the L H side of the burner as shown in Fig 3 It is advisable to provide a means of isolati
13. everse order e v TO REPLACE THE OXY PILOT ASSEMBLY The assembly is not an item that can be serviced as part of its calibration depends on the proximity of the spark electrode and thermocouple tip However with the burner assembly removed as described above the complete assembly can be replaced by removing the tube nut and tube trom the base of the pilot the thermocouple from the FSD and the igniter lead Two screws secure the bracket to the framework Replace in reverse order the spark gap is shown in fig 14 vi TO REPLACE THE FILTER ASSEMBLY With the burner assembly removed as described above Unscrew and remove the tube nut and tube at the base of the oxy pilot assembly the filter is located in the bottom of the assembly Replace in reverse order See fig 15 vii TO REPLACE CONTROL UNIT With the burner assembly removed as described above Unscrew the control unit bracket Pull out the multipin connector from the rear of the box and separate the plug socket connection to the micro switches Replace in reverse order vii TO REPLACE THE FLOW SENSE SWITCH Ensure the electrical supply is switched off remove terminal guard four screws fan cover six screws and deflector plate three screws Disconnect the three leads and the red and blue silicone tubes from the flow sense switch noting their positions fig 20 remove and replace the switch 1X TO CHECK THE FLOW SENSE SWITCH FUNCTIONS CORRECTLY The flow sense switch is calibra
14. fret recommended is shown as Fig 17 in this instruction It has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes If other fronts and frets are to be used they must have a minimum open area in the fret of 50 sq cms and 60 sq cms in the front A hearth must always be provided to project forward of the opening a minimum of 350mm depth and 150mm either side of the fire opening and must be of a minimum thickness of 12mm dependant on the floor construction with a perimeter height of 50mm This is to ensure combustible materials carpets etc are not in close proximity to the radiant surfaces The area under the fire box must have a minimum non combustible thickness dependant on the floor construction This appliance must be fitted to a non combustible surface ie a plaster wall or plasterboard Any wallpaper must be locally removed from the surface behind the firebox Additional purpose built ventilation is not required for this appliance in GB only For Ireland IE ventilation is required with a minimal cross sectional area of 100 sq cms and should be checked regularly to ensure that it is free from obstruction It must be fitted in accordance with the rules in force LOCATION OF THE APPLIANCE The location of the appliance will be determined by the requirements for a suitable position for the flue outlet terminal A guide to the constraints regarding the position of the flue term
15. guide for gas installations into timber framed dwellings DM2 2nd edition is published by British Gas and should be adhered to INSTALLATION REGULATIONS AND REQUIREMENTS The appliance must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the manufacturers instructions Failure to do so could lead to prosecution The following are the relevant Codes of Practice and British Standards The Building Regulations issued by the Department of the Environment The Building Standards Scotland Consolidation Regulations issued by the Scottish Development Department BS 3456 Pt 101 1987 BS 5440 Pt 1 1990 BS 5871 Pt 3 199 BS 6891 1988 Da TECHNICAL DATA Overall height 552mm Width 402mm Depth E 76mm Depth with Front and Fret 220mm Type of Gas G20 Only Supply Pressure 20 mbar 1mbar Cold Electrical Supply 230 240 v 50 Hz Fused 3 amp GAS INPUTS Gross Thermostat settings Max 6 6 kW 22500 Btwh Min 2 83 kW 9700 Btwh Pilot 0 26 kW 890 Btwh Main Injector Type Bray Cat 82 600 Pilot OP Oxy Pilot NG 9022 Gas Connection 8mm O D Tube WEIGHT 28 3 kg IMPORTANT NOTES Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young elderly and infirm a fireguard conforming to BS 6539 or BS 6778 is used The type of front and
16. he plug Reconnect the bumer and test for leaks Xi TO REPLACE THE FAN UNIT Remove the terminal guard four screws fan cover six screws and deflector plate three screws Provided no damage is apparant to the scroll unit the fan motor and impellor can be replaced by disconnecting the brown blue and yellow leads and removing the three hex headed bolts holding the assembly in the scoll unit The leads are reconnected colour to colour in the terminal block Replace the covers etc separate micro switches for on IGN and off the FSD interrupter The fan controller is controlled by two micro switches as an assembly Withdraw the bumer trav as detailed above The micro switches are held in place by self tap screws the IGN and FSD micro switches connect to the spark generator and controller micro switches by plug and socket to the control unit xii TO REPLACE THE MICRO SWITCH ASSEMBLIES The spark generator is controlled by Check for gas soundness after any removal and replacement of components a es FIG 1 TERMINAL POSITION MINIMUM DISTANCE A Directly below an openable window or other opening e g air brick 300mm B Below gutters soil pipes or drain pipes 75mm C Below eaves 200mm D Below balconies or car port roof 200mm E From vertical drain pipes and soil pipes 75mm F From internal or external corners 300mm G Above ground roof or balcony level 300mm H From a su
17. inal is printed below and is an extract from BS 5440 Pt 1 1990 The terminal must be positioned such that the combustion products can diperse freely at all times 2 n certain weather conditions a terminal may steam and a siting for the flue where this could cause a nuisance should be avoided 3 f the terminal discharges onto a passageway or pathway or over adjoining property check that the terminal will not obstruct the passageway In some areas local bye laws ask for a minimum height for projections from a wall above a public footpath Check any local bye laws 4 If the terminal is fitted within 850mm of a plastic gutter or within 450mm of painted eaves or a painted gutter an aluminium shield of at least 750mm long should be fitted to the underside of the gutter or painted surface Dimensions B amp C in Fig 1 S If a terminal is fitted less than 2m above a balcony above ground or above a flat roof to which people have access then a suitable terminal guard must be provided Dimension G in Fig 1 6 A terminal sited in a car port or other single story add on extension should be treated with care and the additional notes apply Whilst other building features may satisfy the dimensional requirements they are not included e g covered passages between dwellings ADDITIONAL NOTES FOR CAR PORTS AND OTHER SINGLE STORY ADD ON EXTENSIONS 1 Any car port or other add on extension should consist of a roof and one wall If it con
18. material such as rock wool should be used between the hot box and the wall and spacers fabricated to fix the appliance Note The appliance is not fixed in position at this stage TIMBER FRAME DWELLING INSTALLATION Where a flue is to be installed in a timber frame dwelling care must be taken to protect combustible material from contact with the hot surfaces of the hot box and flue and it should be fitted in accordance with the guide lines stipulated in DM2 2nd edition document printed by British Gas The requirements relating to the location of the appliance and surround are the same as listed previously although special consideration should be given to the position of any vertical studwork When a suitable location is found between vertical supports that allows the flue heat shield to be fitted and also satisfy the flue terminal and surround requirements position the fire on the hearth and mark the outline of the hot box Remove the hot box and measure up 476mm find the centreline measure and mark a rectangle for the heatshield as shown in fig 7 NOTE THAT THE FIXING SCREWS SECURING THE FIRE IN PLACE MUST NOT BE SCREWED INTO THE STUDWORK OR TIMBER STRUCTURE IN ORDER TO PREVENT TRANSFER OF HEAT THROUGH THE FIXINGS When plasterboard is used the weight of the appliance must be supported on the hearth Carefully remove the rectangular section avoiding damage to the vapour barrier behind the plasterboard Cut the vapour barrier diagonally and fold ba
19. n fig 21 The socket must be accessible after the installation of the appliance It is essential that the electrical supply in the property should be properly earthed in accordance with current IEE regulations ASSEMBLY OF THE FAN BOX TO THE EXTERIOR WALL With the flue attached to the rear of the fire and located in the correct position the flue and wiring harness will be protruding from the wall In most installations the flue tube will need to be trimmed to the correct length To establish the maximum length required the fan box mounting plate will have to be removed from the fan box assembly by unscrewing the six fixing screws around the fan box cover and the three self tap screws holding the deflector plate in position This will give access to the four fixing screws on the fan box mounting plate see figs 9 amp 10 Feed the wiring harness through the 21mm hole in the fan box mounting plate and slide over the flue tube Hold in position against the wall and place a straight edge across the outer flanges Scribe a line to mark the maximum protrusion of the duct See fig 10 Remove the plate To prevent distortion of the flue tube it is recommended that the appliance 1s withdrawn from the hole and the flue duct is trimmed down to the correct length with tin snips or hacksaw Refit the appliance and fix in position using the screws provided Replace the plate spot drill through the four fixing holes and using plugs and screws provided fix in
20. nd disconnecting the spark generator Replace in reverse order 1 TO CLEAN OR REPLACE THE INJECTOR With the burner assembly removed as described above Remove the aeration sleeve retaining screw Unscrew the compression nut connecting the gas supply to the elbow injector while supporting the injector to prevent distortion of the framework Unscrew the compression nut and remove the gas supply tube from the gas control valve hold the injector lock nut with a spanner and rotate the injector Replace in reverse order ensure the aeration sleeve retaining screw is replaced 1i TO REPLACE THE GAS PROTECTOR Valve FSD With the burner assembly removed as described above the gas protector can be replaced by undoing and remaking the gas connections and the interrupter Replace components in reverse order Carry out a leak check prior to refitting the burner ii TO REPLACE THE THERMOSELECTOR CONTROL With the burner assembly removed as described above remove the knob facia panel two self tap screws control securing nut inlet and outlet gas pipes Remove the thermostat phial and control replace in reverse order Carry out a leak check prior to refitting the burner iV TO REPLACE THE SPARK GENERATOR The burner does not require removal Remove the battery Remove the heat shield self tap screw protecting the generator and nut holding the generator in place note position of leads for replacement Replace generator replace the components In r
21. ng the gas supply to the appliance for servicing using the isolation cock supplied Provision is made for entry into the box in both L amp R hand sides although for ease of installation it is recommended that the gas feed is made from the left hand side Any pipe used under the tray must be in ngid tube such as bundy Suitable pieces of bundy are included in the fitting kit to assist the installer Where a concealed gas supply is used the installer is reminded of the requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement and shall be constructed to prevent passage of gas either between the pipe and sleeve or sleeve and wall NOTE The gas supply to the appliance must not be left ON until such time the installation is complete and tested ELECTRICAL SUPPLY Wiring external to the appliance must be in accordance with the IEE wiring regulations and any local additions to those regulations The appliance is supplied for 230 240 V 50Hz single phase operation fuse rating 3 amp As certain installations would require a concealed electrical connection a fused double pole isolator having a contact separation of at least 3mm in all poles serving only the appliance must be used For installations which use an existing 13 amp switched socket the wiring of a suitable approved plug is shown i
22. not harmful may require additional ventilation until the odour has disappeared This product uses fuel effect pieces gaskets and insulation material containing Refractory Ceramic Fibre RCF which are man made vitreous silicate fibres Excessive exposure to these materials may cause temporary irritation to eyes skin and respiratory tract consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum This fire will run for 4 4 hours on one therm of gas with the gas control on the high setting EUM Clearances Side Minimum clearance required to any combustible material to the side of the appliance must be 150mm Shelves Minimum clearance to the underside of a 150mm deep combustible shelf from the hearth must be 790mm add 12 5mm to this dimension for every 25mm increase in the depth of the shelf To light the appliance Press down the control button at the right top corner of the surround The fan should be heard to start initially on high speed and then reducing to low speed a spark will be heard and the gas will light at the pilot positioned at the centre of the front simulated coal if a spark is not heard check battery Hold for a period of 10 15 seconds and release the main burner will light A taper may light the appliance by placing the lit taper over the coal front at the approximate centre position and pressing the control button See Fig 1 The thermoselecto
23. ntil a full lighting sequence is repeated A battery operated spark generator is used to ignite an Oxy pilot sensor O D S which will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required It is important when relaying the coal bed and coals to follow the instructions correctly TECHNICAL DATA TYPE OF GAS G20 only SETTING PRESSURE 20 mbar 1 mbar cold GAS INPUTS Gross Max 6 6 kW 22500 Btu h Min 2 83 kW 9700 Btu h Pilot 0 26 kW 890 Btu h IMPORTANT NOTES This appliance is intended for decorative purposes it is designed and manufactured to the relevant requirements of EN 509 BSI S I T 8 and BS 5258 Pt 16 1991 it is for use on Natural Gas Only Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young elderly and infirm a fireguard conforming to BS 6539 or BS 6778 be used Combustible materials should not be put or left on the hearth nor should the coal bed be used to burn rubbish or other materials The type of front and fret recommended is shown as Fig 1 in this instruction it has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes If other fronts and frets are to be used they must have a minimum open area in
24. r control situated behind the ashpan cover fret is to be set to a position which maintains the room at the desired comfort level i e the higher the control setting the higher the mean temperature of the room Adjustments to this control will take time for the effect in the room to be apparent To turn off the appliance and pilot lift the control button IMPORTANT After turning OFF or if the pilot and the appliance goes out for any reason wait for three minutes before attempting to relight Dismantling the Fire Bed for Cleaning Allow the appliance to cool for 1 hour before handling any components Remove the loose coals lift off the simulated coal front and remove the coal support shelf Once all the fibre components have been removed from the firebed check that no debris has fallen in or lodged the burner slots If any debris is present it may be easily removed by using a small piece of thin cardboard to ease out any foreign matter Be sure to remove the cardboard after use Any sooty deposits or debris left on the coals may be removed by using a soft brush or by careful use of a vacuum cleaner Cleaning should be carried out in a well ventilated area or in the open air by gently brushing with the pieces held away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air Any sooty deposit on the thermocouple probe can be cleaned of using a non
25. rface facing a terminal 600mm From a terminal facing a terminal 1200mm J From an opening in the car port e g door window into dwelling 1200mm K Vertically from a terminal on the same wall 1500mm L Horizontally from a terminal on the same wall 300mm Thickness of Hearth T FIG 2 The illustration shown is the recommended CROSSLEE Front amp Fret If an alternative Front amp Fret is used it is important to maintain the equivalent ventilation to that shown Minimum ventilation area of 60 square cms at higher level Minimum ventilation area of 50 square cms at FIG 17 low level e g Facia height Fixing Holes 4 off One Piece Fibre Back Support Shelf Simulated Coal Front Data Plate FIG 18 Terminal Block Control Box Connector Polarising Pin Micro Switches FIG 19 MEN Fan Scroll x Um Fixing o NE Flow Sense Switch Air Pressure Switch Positive Outlet Ne ative i S v wes Se NO Red aie jd C Grey Common Black N Positive Pilot Tube Negative Brass Damper FIG 20 EARTH NEUTRAL LIVE GREEN and YELLOW BLUE Green amp Yellow E BROWN wu ou Connect the GREEN and YELLOW wire to the terminal marked E or the earth symbol or coloured GREEN or GREEN YELLOW o lt 2 LL lt e Connect the BLUE wire to the terminal marked N or coloured BLACK Connect the BROWN wire to the
26. sists of a roof and two other walls the installation shall be treated as suspect and further advice sought 2 If there is any opening in the car port into the dwelling e g door window etc then the terminal must be at least 1200mm away from that opening If itis more than 1200mm then D F H and I shall also apply where D is the vertical distance between the lowest point of the roof and the top of the terminal 3 If the roof is plastic then the installation should be treated with great care as there is no simple way of protecting the roof CLEARANCE TO SHELVES Minimum clearance required to the underside of a 150mm deep combustible shelf from the hearth must be 790mm Add 12 5mm to this clearance for every 25mm increase in depth of shelf See Fig gt 9 CLEARANCE TO SIDE timber surrounds etc Minimum clearance required to any combustible material to the side of the appliance must be 150mm See Fig 2 4 LIST OF COMPONENTS Fire Box Assembly c w Burner Assembly Fan Box Assembly Brass Trim held in place by magnets nstallation amp Servicing Instructions Flue Duct Users Instructions Aluminium Conduit Coal Pack Contains Coal pack A 5 Medium Simulated Coal Front Coal Pack B 8 Small Coal Support Shelf Coal Pack C 2 Triangular Coal Pack D 2 Med Small Fitting Kit Screws amp Wall Plugs Isolation Elbow Bundy INSTALLING THE APPLIANCE To install the appliance it is necessary to have a gas supply
27. tage should be taken of regular servicing and inspection of gas appliances to ensure their continued safe operation Short Parts List Description Crosslee Pt No Coal Support Shelves 42836 Front Simulated Coal 42769 Fibre Back 42830 Set of Coals 42658 9 volt Battery PP3S REGISTRATION RECORD PurchaserS Name cune ouiecte ete be te teee pato bota subo se Lode dupataeobete use bota eoo lu FoDu e Pue lein and Address BEEN T XY SUpplters Name oionistooi n E ORE ES E RENE HN NI VR ERR EH PIE ancdsdelpesee sete d PM d ML ML LE ME eee ee ee EDD iE Date of Purchase ri SOFIA NO auuetusMectcbctoR AIR Ac RR AIR Please return these details with any components returned under guarantee Royal Cozyfires are manufactured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 60p per minute The Illustration shown is the recommended CROSSLEE Front and Fret If an alter native front and fret is used Q Off it is important to retain an equivalent ventilation to that E indicated Vv Qo Minimum ventilation area of 60 sq ems at higher level g M Control Knob TPA Fig Minimum ventilation area uil at low level e g F acia heigkiy N i
28. ted to operate on the differential pressure between the positive and negative pressures from the pitot tubes It is therefore important that these are not adjusted or repositioned To check that the switch changes from the normally closed position when a high back pressure is present e g severe wind conditions carry out the following procedure Remove the terminal guard four screws and fan cover six screws With the appliance operating normally on high heat blank off the flue outlet with a non combustible material this will cause the pressure switch to operate The fan speed will increase and after approximately 4 6 seconds the gas solenoid will close cutting off the supply to the fire The increase in fan speed and delay in shutting off the gas is to reduce the incidence of gusts causing nuisance shutdown NOTE With the appliance switched on during this test the operator should be aware that mains voltages are present within the fan unit x TO REPLACE THE SOLENOID VALVE OR SOLENOID COIL Withdraw the burner tray as detailed above The more common failure is the coil which can be replaced by removing the screw holding the plug connection and the retaining nylock nut and washer To replace the complete valve undo the compression nuts and with the valve removed remove the two fittings from the old valve body Replace in the new body using a suitable thread sealant to ensure a gas tight joint tighten the two compression nuts and refit t
29. terminal marked L or coloured RED Brown Aenea bere The 13 amp plug should be fitted with a 3 amp fuse N Ensure Cord Grip acts on outer cable FIG 21 Pilot Filter e E FIG 22 p MP CONTROL BOX interrupt Ignition SPARK GENERATOR ip ecl cele le WIRING DIAGRAM Le 230 240 V FIG 23 ON OFF REGISTRATION RECORD Purchaser s Name a 52009284 P9 4 C 009 009274t80409AJ904 t09 v 2240492595229098004P50099V9 656p04924 e4002422 290 9292509092285V0ve0 0 n201a999 9 999 and Address aese evsogunevototastsen hbousseuopoetbotuebuestaceotseotovutUutqos4d50204 2 0949986 94495249 9528 2 w 092448 49 9 v9 4585 Supplier s Name aasastubdt 3 5bhoeti ubteteedeteecstuss bpuatetws avututeuestvebasnae 356090 n2vaPry cOUu eQt unte os anecstaveottottont and Address PURO PETE B 8su amp adoOwtd4re udett9201a9b 0vyva dduaen tandeba atsateoss stnpamnaoavsatbeteobhsudinea2spqiaASAas 2092402743 uudttt94t9 Date of Purchase aA EEE EENET Serial No 8 4924050 98206409a42245 6 u 2 25 695n39 u 0qgzevbubauusa Please return these details with any components returned under guarantee CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 SEX SPARES TEL 01422 203963 FAX 01422 204475 SERVICE GSA LTD JTEL 01703 516611 HOLMS 3SfiSSdJHd 30v Td3u GALLUS LON di C02 HOLMS OSI OHS Lid LIUN 3014 NO SANMA 3AISS3OX3 HOLIM
30. to position Ey IMPORTANT THE FAN MOUNTING BOX MUST BE HORIZONTAL TO ENSURE CORRECT OPERATION OF THE FLOW SENSE SWITCH As previously advised the length of wire fastened to the loom is fed through the conduit supplied the flanged end is located nearest the fan Keeping the loom taut slide the conduit through the mounting plate locate over the extruded hole at the rear of the hot box and measure the distance to be trimmed i e between the mounting plate and the flanged conduit Remove the conduit and cut to length removing any burrs from the inside refit and revolve so that the flange is located between the plate and the tag See fig 10 Assemble the fan support plate to the mounting plate by feeding the wiring loom through the extruded hole in the rear of the support plate and slide the flue spigot over the flue tube holding the loom taut Secure to the mounting plate with the four fixing screws provided secure the loom to the base with a cable tie and connect the six wires to the terminal block and the earth lead to the earthing post as shown in fig 11 Colour to colour Excess loom should be laid in the cable store fig 11 avoiding contact with the fan housing Cable ties are supplied should they be required Replace the rear deflector this directs cool air onto the fan bearings replace cover in position If a terminal guard is to be fitted available from your supplier this should be positioned so there is a minimum clearance of
31. turned with the replacement part b Any installation repairs or adjustments have been carried out by a competent person such as the supplier s representative or a CORGI registered installer HAND THESE AND THE USERS INSTRUCTIONS TO THE USER SERVICING INSTRUCTIONS 1 SERVICING Figs 18 amp 19 It is recommended that the appliance is inspected and serviced as necessary regularly by a competent person e g Manufacturer s or Distributor s representatives or CORGI installer The life of the ceramic fibre components will be dependant on the way they are handled used Any damaged or disintegrating parts should be replaced and the specific number of coals should not be exceeded or laid in any manner other than that described in these instructions Check that a correctly dimensioned front and fret is being used The fan unit should be inspected and if there are unusual deposits of soot the fan should be dismantled and cleaned Check that the coal layout conforms to these instructions If the electrical supply cord is damaged it must be replaced by the special cord available from the manufacturer or service agent Crosslee Part Number 42428 a1 0 The inside walls and ceiling in the vicinity of the appliance should be inspected for signs of staining if any the cause must be determined investigated and rectified if it is found to be caused by combustion product spillage The outlet of the fan should be checked for obstruction any overgrown
32. vegetation etc which could impede the free flow of air should be brought to the attention of the householder GENERAL A REMOVAL OF DEBRIS OR SOOT DEPOSITS Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes Once all the ceramics are removed from the firebed check that no debris is located in the burner slot If any debris 1s present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter Be sure to remove the cardboard after use Any sooty deposits or debris left on the coals may be removed by using a soft brush or by careful use of a vacuum cleaner Any sooty deposit on the thermocouple probe can be cleaned off using a non fluffy cloth DO NOT USE ABRASIVE MATERIALS B SERVICING COMPONENTS BELOW THE BURNER ASSEMBLY Turn OFF the gas and electrical supplies to the appliance Remove brass trim held in position by magnets surround six self tap screws battery heat shield self tap screw and thermostat cover two self tap screws taking care not to damage the thermostat capillary tube Remove coals front simulated coal canopy two self tap screws and fireback Remove the fibre support shelf and the L amp R hand cover plates two self tap screws each The burner assembly may be now be removed by disconnecting the gas supply at the inlet elbow separating the two plug socket assemblies removing the leads from the interrupter a
33. z 50 sq ems L amp R Hand Coal Support Shelves LS SOA A LSAT DRY E Ly oe T J Position for taper et Battery X zs LAU a Control Knob Isolation Cock Fressure Test Point Thermostat Phial Fig 2 Fig 4 INSTALLATION amp SERVICING INSTRUCTIONS THIS CAT by APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB amp IE HAND THESE INSTRUCTIONS TO THE USER 82417 ISSUE 1 DESCRIPTION The Slimline Turbo is a decorative gas fire which incorporates a horizontal flue that has been designed specifically to be used in applications that do not have a conventional chimney or flue but can be located so that the flue can terminate on an outside wall The maximum permissible wall thickness is 600mm and the minimum 100mm The flue is connected directly to the back of the hot box it must be straight with no bends or elbows permitted and is connected to a fan unit housed on the exterior wall to extract the products of combustion A standard fire surround back panel and hearth which comply to all the relevant standards and precautions may be used with this appliance A Flame Supervision Device FSD is fitted to ensure that should the pilot flame be extinguished for any reason including turning off the appliance the gas supply to the burner is cut off until a full lighting sequence is repeated The fire is switched ON and OFF from a push button
Download Pdf Manuals
Related Search
Related Contents
Figurer l`espace/temps de Tours pré-industriel 取扱説明書 ブロワ nur für Piccolo 2 【HV7】7/(14)/(18)/21/28/50/144/430MHz帯高能率 bingo ADTRAN 4200659L1 Switch User Manual Exceleram 12GB DDR3 PC3-10666 attenzione!!! rischio di danno uditivo nelle normali Milwaukee 2676-20 Use and Care Manual Copyright © All rights reserved.