Robertshaw 9701i2 Install Sheet

image

Contents

1. R 24VAC Y1 1st stage heating cooling E W1 Emergency heat W2 2nd stage heating Y2 2nd stage cooling L System fault indicator O Cool active reversing valve B Heat active reversing valve G Fan Equipment Wiring Terminals Please refer to heat pump installation manual for proper terminations If terminal E is not supplied add jumper across E W1 and W2 on the thermostat 00000000090 Select either the Fahrenheit or Celsius temperature scale Press Next Select Temperature 4 Scale C 8 Select the type of heating system that will be used with the thermostat Press Next 1st Stage Heat Equip None Strip Heat Pump Back Auto changeover allows automatic 9 switching between heating and cooling Make your selection Press Next Enable r Auto Changeover Yes Service reminders are available for Heat System Heat Pump Cool System Filter UV Light and Humidifier Pad All can be set to OFF or from 1 to 12 months Press Next Reminder To Service Heat System In See G Mark mounting hole locations on wall P Mark mounting hole locations on wall using unit base as template Connect wiring between the thermostat and equipment For Model 9725i2 2 heat 2 cool heat pump with furnace Thermostat TERMINAL DESIGNATIONS C 24VAC Common R 24VAC Y1 1st stage heating cooling E W1 Emergency heat W2 2nd stage heating Y2 2nd stag
2. Opening ee ee ee ee e e Remove 1 2 of insulation from end of each wire Connect wiring between the thermostat and equipment For Model 972512 2 heat 2 cool gas electric Thermostat TERMINAL DESIGNATIONS C 24VAC Common R 24VAC Y1 1st stage cooling E W1 1st stage heating W2 2nd stage heating Y2 2nd stage cooling L Not used O Not used B Not used G Fan Equipment Wiring Terminals Please refer to furnace installation manual for proper terminations 0000000000 Set the time Hours and minutes are set separately An AM PM indicator automatically changes based on the hour chosen Press Next Set the date 4 First set the month Press Next Then set the day Press Next Finally set the year Press Next Set Date Month 1 1 05 Back Next Vv Choose the time format 12 hour clock or 24 hour clock Press Next Select Time Format 4 24hr 6 To activate the Auto Daylight Saving Time feature choose either Standard April October or Extended March November Press Next Auto Adjust For DST 4 Standard Apr Oct Extended Mar Nov Back Next 2 Open the case with a screwdriver Place in slot and gently pry forward at all four locations Connect wiring between the thermostat and equipment For Model 9725i2 2 heat 2 cool heat pump with strip heat Thermostat TERMINAL DESIGNATIONS C 24VAC Common
3. indicator Indoor sensor Cool active reversing valve terminal block Heat active reversing valve z Fan To sensors gt Outdoor sensor terminal block Equipment Wiring Terminals Please refer to heat pump installation manual for proper terminations 0010000090 DELUXE PROGRAMMABLE THERMOSTATS Operational Mode Chart No 2nd HVAC Mode Stage is Emer Outgodr Ist Stage Standard Add On 2nd is na Temperature Between Y1 W2 Y1 W2 3 Noses vi em foa a oe 1 The 2nd stage is not used for heating when the outdoor temperature is not between the two balance points 2nd Stage is 2nd Stage is a 2nd Stage is a Furnace Strip Heat Pump Heat Pump Only Y1 W2 Y1 W2 Y1 Y1 3 When no sensor is present the thermostat behaves as If the outdoor temperature is always between the balance points 2 Standard and Add On apply when the 2nd 4 Heat Pump Only applies to the 9725i2 when stage is on Y1 is either on Standard or off it is configured as Heat Pump in both 1st and Add On 2nd stage Connect wiring between the thermostat and equipment For Model 9701i2 1 heat 1 cool gas electric Thermostat TERMINAL DESIGNATIONS C 24VAC Common R 24VAC Y1 1st stage cooling E W1 1st stage heating O Not used Not used Fan Equipment Wiring Terminals Please refer to furnace installation manual for proper terminations 1
4. 3 Replace cover on thermostat Turn on power to unit and proceed with programming per instructions on the display or in the users manual O O Many 20 MOYO Outie FO F Rieti NOTES 7 Connect wiring between the thermostat and equipment For Model 970112 1 heat 1 cool heat pump with strip heat emergency Thermostat TERMINAL DESIGNATIONS C 24VAC Common R 24VAC Y1 1st stage heating cooling E W1 Emergency heat Cool active reversing valve Heat active reversing valve Fan Equipment Wiring Terminals Please refer to heat pump installation manual for proper terminations amp Recycling Thermostat If this thermostat REPLACES a thermostat that contains mercury DO NOT discard the old thermostat in the regular trash Mercury is harmful to humans and the environment For this reason do not open break or crush the mercury cell If mercury leaks from a damaged cell DO NOT touch or handle mercury with bare hands Use protective non absorbent gloves to place mercury into a sealable container Fill the container with sand or another absorbent material and seal the container completely Return the mercury or mercury products in a sealed container to Invensys Climate Controls or a local recycling center for proper disposal If you have any questions call Robertshaw technical support at 1 800 445 8299 In U S Invensys Controls Americas 28C Leigh Fisher Blvd El Paso TX 79906 Attn
5. DELUXE PROGRAMMABLE THERMOSTATS Quick Start Installation Manual models 9701l2 and 9725L2 o onge Monday Jun 20 gt _ gt gt 9 110 1180 Installation DOs and DON Ts DO e Shut off all power to system before installing e Read entire manual before installing e Make sure that all wiring conforms to national and local codes DO NOT e Install on voltages greater than 30 VAC e Short jumper across terminals on the gas valve or at the system control e Connect ground to any terminal in this unit e Install on outside walls or in direct sunlight DELUXE PROGRAMMABLE THERMOSTATS Setup Wizard Quick Start Guide The Setup Wizard allows you to quickly step through the setup process This guide shows a typical setup for a basic heating system Ihe screens you see depend on thermostat model and your heating cooling configuration NOTE Use the A or V button to select a list item or to change the value of a number Use the gray buttons below the display to choose No Yes Back Next Next Char or Accept when appropriate 1 Selecting Yes allows you to go through the setup process Would You Like To Run the Setup Wizard Choose either English Espanol or 2 Francais as the display language This can always be changed after the Setup Wizard is complete Press Next Select Language 4 Espanol Fran ais Back 1 Select location for installation Cut 1 1 2 out
6. Mercury Recycling Center In Canada Invensys Controls Americas 3515 Laird Road Unit 14 Mississauga Ontario L5L 5Y7 Attn Mercury Recycling Center NOTES Invensys Controls Americas 515 South Promenade Avenue Corona CA 92879 1736 United States of America Made in U S A www about i series com 110 1180
7. e cooling L System fault indicator Cool active reversing valve Heat active reversing valve Fan Equipment Wiring Terminals Please refer to heat pump installation manual for proper terminations If terminal E is not supplied add jumper across E W1 and W2 on the thermostat 00000000090 Contact information can be entered 11 at the factory Talk to your Robertshaw sales representative about this feature To edit information Use the A or V button to scroll through the character list Press Next Char to move to the next character Press Accept to move to the next line and finish editing Set Contact Info 4 Name NBC HEATERS 123 555 2345 Accept Next Char V 6 Align unit base over plastic anchors embedded in wall and secure with the screws provided 4 Drill 3 16 holes at marked locations on wall Insert plastic anchors into holes Press anchors into holes until flush Connect wiring between the thermostat and the indoor sensor 9020i and the outdoor sensor 90251 if used Use twisted pair wiring 22AWG minimum with a maximum length of 300 feet or 100m 11 Connect wiring between the thermostat and equipment For Model 972512 2 heat 2 cool 2 stage heat pump with strip heat Thermostat TERMINAL DESIGNATIONS C 24VAC Common R 24VAC Y1 st stage heating cooling E W1 Emergency heat strip W2 2nd stage heating Y2 2nd stage cooling L System fault