1.                         5     VPAP    5    POSITIVE AIRWAY PRESSURE DEVICE    Welcome Guide  English       Welcome  Thank you for choosing the VPAP ST or VPAP S  Before operating this device  please read the entire    Welcome and Information Guides   Module Adapter  N    SD card slot          DC power inlet Air filter    Air outlet    VPAP at a glance    The VPAP system comprises the following elements   e VPAP device   Air tubing   90W power supply unit   S9 travel bag   SD card     S9 SD card  protective folder   Optional components include   e H5i heated humidifier   Standard air tubing     SlimLine air tubing   3m air tubing   ClimateLine  heated air tubing   ClimateLine          heated air tubing   SOW power supply unit  does not support H5i     Power Station    battery pack   DC DC Converter 24V 90W   1  English       Setup    1     Connect the DC plug of the power supply unit to the rear of the VPAP    2  Connect the power cord to the power supply unit    3  Plug the other end of the power cord into the power outlet    4  Connect one end of the air tubing firmly onto the air outlet    5  Connect the assembled mask system to the free end of the air tubing   Notes     For more information on assembling your mask see your mask user guide   Recommended masks are available on www resmed com on the Products page  under Service  amp  Support             LCD screen   Displays the menus   treatment screens and  reminders     Start Stop button  Starts or stops  treatment        
2.                 Notes     gt     f your clinician has enabled SmartStart your device will start  automatically when you breathe into the mask and stop automatically  when you remove the mask     gt  7  power is interrupted during treatment  the device automatically  restarts therapy when power  5 restored     Viewing the treatment screens    Depending on how the system has been configured  you will see one of the following example screens     shown in the ST mode  once therapy has started     Al HUMIDITY LEVEL        CLIMATE CTRL    ol   NET oF                 5          v H5i humidifier v  15  humidifier      ClimateLine or ClimateLine           heated air tube    Climate Control   Auto    TREATMENT 1 2  SpO2 98  Pulse 120  Leak 218    12    MV 7 2 Vt 600           Standard VPAP without     Oximetry data via the  optional accessories oximeter adapter       v H5i humidifier     ClimateLine or ClimateLine   MAx  heated air tube   v Climate Control   Manual    In S and ST modes  the fixed lines on the pressure bar indicate the expiratory and inspiratory pressures   In CPAP mode  only 8 set pressure is shown  While the treatment is ramping  indicated by an orange  ramp icon below the pressure bar   the pressure values appear in orange  When a set pressure is reached    these values are displayed in white     7  English    To toggle between treatment screens 1 and 2  press 68 from your HOME screen     TREATMENT 2 2 TREATMENT 2 2  Ti           Ti Max 2 0 J 1 7 Ti Max 2 0  H  1 2 0
3.    Setup menu   Allows you to   make changes   to settings or   Info menu exit from the   Allows you to Ty  view your sleep  statistics or exit   from the menu  Push dial   Turning the dial   allows you to   scroll through the   menu and change   settings  Pushing the         VPAP basi    The control panel of your VPAP device includes dial allows you to  an LCD screen awell as a Start Stop button         8 on and  Push dial and the Info and Setup menu keys  contirm your cnoice     Home A       N         Ramp dl    Heated tube 1    Humidity level    Climate    Control      Sta rustop Oy  Push dial        Setup                     Info menu 1    3  English    Adjusting ramp time    Designed to make the beginning of treatment more comfortable  ramp time is the period during which  the pressure increases from a low start pressure to the treatment pressure  To adjust your ramp time     W RAMP       1  From your HOME 2  Press 68 E 3  Turn 68 until 4  Press   to  screen  tun     The selection is the ramp time confirm your  until the RAMP highlighted in you require 15 choice   screen 15 displayed orange  displayed   in blue     Using mask fit    You can use mask tfit to help you fit your mask properly  This feature delivers treatment pressure for 8   three minute period  prior to starting treatment  during which you can check and adjust your mask fit to   minimise leaks    1  Fit your mask as described in the mask user guide    2  From your home screen  push and hold  amp  for three 
4.  Ti Min 5 HE      Spont       1 95 C       v Treatment with device trigger     Treatment with spontaneous     Timed  and cycle  Timed  trigger and cycled breaths  Ti Max or Ti Min  breath  indicators    Viewing the Info menu  The Info menu has a series of screens showing your sleep quality  sleep report and service information              To view the Info menu  push    from your HOME screen        SLEEP QUALITY SLEEP REPORT  ine ine    AL Usage 8 2 ns                v Inthe Sleep Quality screen  v Inthe Sleep Report  only the Vv        the Service information   you can always view your period can be changed    the device run hours  usage hours during the last other values are for display  includes warm up cool down  session and         enabled by only  times for the humidifier  and  your clinician  data on mask  the software Identifications  fit and AHI is displayed  are displayed     To return to the HOME screen  push il     Cleaning and maintenance    Refer to your mask and humidifier user guides for detailed instructions regarding the care of these  devices     Daily    Remove the air tubing by pulling on the finger grips on the cuff  Hang it in a clean  dry place until next  use     Weekly    1  Remove the air tubing from the VPAP device and the mask    2  Wash the air tubing in warm water using mild detergent    3  Rinse thoroughly  hang  and allow to dry    4  Before next use  reconnect the air tubing to the air outlet and mask     Monthly    1  Wipe the exterior of th
5. anufacturer  ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia  Distributed by  ResMed Corp 9001 Spectrum Center    Boulevard San Diego CA 92123 USA    EC   REP   ResMed  UK  Ltd 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK  See www resmed com for other  ResMed locations worldwide     For patent information  see www resmed com ip     S9 VPAP  H5i  ClimateLine  SlimLine and SmartStart are trademarks of ResMed Ltd and 59  ClimateLine  SmartStart and VPAP are registered          in U S  Patent and Trademark Office      2012 ResMed Ltd  0123    Global leaders in sleep and respiratory medicine www resmed com       
6. e VPAP with a damp cloth and mild detergent   2  Check the air filter for holes and blockage by dirt or dust  Replace the air filter if necessary     Replacing the air filter    Replace the air filter every six months  or more often If necessary    1  Remove the air filter cover from the back of the VPAP device   2  Remove and discard the old air filter   3  Insert anew ResMed air filter ensuring that         5   sitting flat in the air filter cover   4  Replace the air filter cover        Air filter cover       Air filter    9  English    SD card    An SD card has been supplied  to gather therapy data from  your VPAP device and provide  settings updates from your  clinician  When instructed to do  so  disconnect the VPAP device  from the power outlet  remove  your SD card  insert         in the  protective folder and send it to  your clinician     Removing the card    1  Push in the SD card to  release it    2  Remove the card    3  Insert the card into the  protective folder    4  Send the protective folder  back to your clinician as  instructed    For more information on   removing and inserting your   card refer to the S9 SD Card   Protective Folder provided with   your device  Please retain the   S9 SD Card Protective Folder   for future use                                    Notes     For Troubleshooting information  refer to the Information Guide   For more product information  see www resmed com     368698 1 2012 02  S9 VPAP ST   S9 VPAP 5    WELCOME  EUR1           M
7. seconds  One of the following MASK FIT  screens is displayed     MASK FIT MASK FIT       3     necessary  adjust your mask  mask cushion and headgear until you have a Good mask fit   After three minutes  the pressure reverts to the set pressure and treatment will begin  You can end  mask fit at any time by pressing       Selecting the mask type  To select your type of mask     SETTINGS       2 Tube Standard    Mask Pillows    Mask Fit   gt      lt  lt   HOME    1h Frese     the SENGS  screen is displayed     0 SETTINGS            Tube Standard         Mask Fit   gt    lt  lt   HOME    4  Turn   until the mask  setting that you require is  displayed        6 SETTINGS  2 Tube Standard    Mask Fit   gt      lt  lt   HOME    2  Turn   until Mask is  displayed in blue     Game SETTINGS  ont Tube Standard    Mask Full Face    WE  ai     lt  lt   HOME    5  Press   to confirm your    choice         lt 3 SETTINGS  2 Tube Standard    a    Mask Fit   gt      lt  lt   HOME       3  Press S     The selection is highlighted  in orange        6  Push     to return to the  HOME screen     9  English    Getting started      Make sure the power is connected     Adjust the ramp time         required     Fit your mask as described in your mask user guide               start therapy  simply breathe into the mask and or press         Lie down and arrange the air tubing so that it is free to move if you  turn in your sleep              stop treatment at any time  remove your mask and or press     
    