1. Home Humidity level 0 1 Setup menu al Allows you to make changes Heated tube g to settings or Climate lt 4 exit from the Control 40 Allows you to aie view your sleep Start Stop y statistics or exit from the menu Push dial Push dial amp Turning the dial atl allows you to scroll the Setup menu menu and change sia settings Pushing the Infomenu 1 dial allows you to The Info and Setup menus are disabled if S9 Essentials enter into a menu and has been enabled clinician confirm your choice 3 English Adjusting ramp time Designed to make the beginning of treatment more comfortable ramp time is the period during which the pressure increases from a low start pressure to the treatment pressure To adjust your ramp time wo RAMP AR RAMP 1 From your HOME 2 Press 68 E 3 Turn amp until 4 Press amp to screen turn The selection is the ramp time confirm your until the RAMP highlighted in you require 5 choice screen 15 displayed orange displayed in blue Using mask fit You can use mask tfit to help you fit your mask properly This feature delivers treatment pressure for 8 three minute period prior to starting treatment during which you can check and adjust your mask fit to minimise leaks 1 Fit your mask as described in the mask user guide 2 From your home screen push and hold 4 for thre
2. the air tubing in direct sunlight as it may harden over time and eventually crack e Do not wash the air tubing in a washing machine or dishwasher Weekly 1 Remove the air tubing from the VPAP device and the mask 2 Wash the air tubing in warm water using mild detergent 3 Rinse thoroughly hang and allow to dry 4 Before next use reconnect the air tubing to the air outlet and mask Monthly 1 Wipe the exterior of the VPAP device with a damp cloth and mild detergent 2 Check the air filter for holes and blockage by dirt or dust Replace the air filter necessary Replacing the air filter Replace the air filter every six months or more often If necessary 1 Remove the air filter cover from the back of the VPAP device 2 Remove and discard the old air filter 3 Insert a new ResMed air Air filter cover filter ensuring that it is sitting flat in the air filter cover 4 Replace the air filter cover Notes e Ensure the air filter and air filter cover are fitted at all times e Do not wash the air filter The air 4 filter is not washable or reusable Air filter 9 English Notes e For Troubleshooting information refer to the Information Guide gt For more product information see www resmed com SD card An SD card has been supplied to gather therapy data from your VPAP device and provide settings updates from your clinician When instructed to do so d
3. VPAP ST VPAP 5 POSITIVE AIRWAY PRESSURE DEVICE Welcome Guide English Welcome Thank you for choosing the VPAP ST or VPAP S Before operating this device please read the entire Welcome and Information Guides Module Adapter N SD card slot DC power inlet Air filter Air outlet VPAP at a glance The VPAP system comprises the following elements e VPAP device Air tubing 90W power supply unit travelbag SD card SD card protective folder Optional components include e H5i heated humidifier Standard air tubing SlimLine air tubing 3m air tubing ClimateLine heated air tubing ClimateLine heated air tubing SOW power supply unit does not support H5i e Power Station battery pack DC DC Converter 24V 90W 1 English Setup 1 Connect the DC plug of the power supply unit to the rear of the VPAP device 2 Connect the power cord to the power supply unit 3 Plug the other end of the power cord into the power outlet 4 Connect one end of the air tubing firmly onto the air outlet 5 Connect the assembled mask system to the free end of the air tubing Notes e For more information assembling your mask see your mask user guide Recommended masks are available on www resmed com on the Products page under Service amp Support VPAP basics LCD screen Displays the menus treatment screens and reminders Start Stop button Starts or stops treatment
4. e seconds One of the following MASK FIT screens is displayed MASK FIT MASK FIT 3 necessary adjust your mask mask cushion and headgear until you have a Good mask fit After three minutes the pressure reverts to the set pressure and treatment will begin You can end mask fit at any time by pressing 68 S9 Essentials S9 Essentials is designed to make device interaction and menu navigation easier for you If enabled by the clinician S9 Essentials disables the Info and Setup functionality so that you can simply start and stop therapy and adjust ramp humidification and Climate Control Selecting the mask type To select your type of mask Ge SETTINGS Tube Standard 8 SETTINGS Tube Standard SETTINGS Mask Pillows Mask Fit gt lt lt HOME Mask Fit gt Mask Fit gt lt lt HOME lt lt HOME 1 Press SETTINGS 2 Turn 68 until Mask is 3 Press The selection is screen 15 displayed displayed in blue highlighted in orange Gam SETTINGS 5 SETTINGS Se Tube Standard SE Tube __ Standard Mask ace Mask Full Face Mask Fit gt Mask Fit gt iy lt lt HOME lt lt HOME Push Dial setup 4 Turn until the mask 5 Press 8 to confirm your 6 to return to the setting that you require is choice HOME screen displayed Note Selecting the mask type is not possible if S9 Essential
5. isconnect the VPAP device from the power outlet remove your SD card insert in the protective folder and send it to your clinician Removing the card 1 Push in the SD card to release it 2 Remove the card 3 Insert the card into the protective folder 4 Send the protective folder back to your clinician as instructed For more information on removing and inserting your card refer to the SD Card Protective Folder provided with your device Please retain the SD Card Protective Folder for future use 368698 2 2013 01 S9 VPAP ST S9 VPAP 5 WELCOME EUR1 Manufacturer ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 1 Spectrum Center Boulevard San Diego CA 92123 USA ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip 59 H5i ClimateLine SlimLine SmartStart and VPAP are trademarks of ResMed Ltd 59 ClimateLine SlimLine SmartStart and VPAP are registered in U S Patent and Trademark Office 6 2013 ResMed Ltd 0123 Global leaders in sleep and respiratory medicine www resmed com
6. s has been enabled by your clinician 5 English Getting started Make sure the power is connected Adjust the ramp time required Fit your mask as described in your mask user guide start therapy simply breathe into the mask and or press Lie down and arrange the air tubing so that it is free to move if you turn in your sleep stop treatment at any time remove your mask and or press Notes e fyour clinician has enabled SmartStart your device will start automatically when you breathe into the mask and stop automatically when you remove the mask e fpower is interrupted during treatment the device automatically restarts therapy when power is restored Viewing the treatment screens Depending on how the system has been configured you will see one of the following example screens shown in the ST mode once therapy has started CLIMATE CTRI HUMIDITY LEVEL HUMIDITY LEVEL FX tal v H5i humidifier v 15 humidifier v H5i humidifier ClimateLine or ClimateLine v ClimateLine or ClimateLine heated air tube heated air tube Climate Control Auto Climate Control Manual TREATMENT 1 2 Sls Standard VPAP without v Oximetry data via the optional accessories oximeter adapter In S and ST modes the fixed lines on the pressure bar indicate the expiratory and inspiratory pressures In CPAP mode only 8 set pressure is shown While the
7. treatment is ramping indicated by an orange ramp icon below the pressure bar the pressure values appear in orange When a set pressure is reached these values are displayed in white 7 English To toggle between treatment screens 1 and 2 press from your HOME screen v Treatment with device trigger Treatment with spontaneous Timed and cycle Timed trigger and cycled breaths Ti Max or Ti Min breath indicators Viewing the Info menu The Info menu has a series of screens showing your sleep quality sleep report and service information To view the Info menu push 1 from your HOME screen SLEEP QUALITY SLEEP REPORT faye SLEEP REPO Usage 8 rs EE SERVICE v Inthe Sleep Quality screen v Inthe Sleep Report only the Vv _ Inthe Service information you can always view your period can be changed the device run hours usage hours during the last other values are for display includes warm up cool down session and enabled by only times for the humidifier and your clinician data on mask the software Identifications fit and AHI is displayed are displayed To return to the HOME screen push 1 Cleaning and maintenance Refer to your mask and humidifier user guides for detailed instructions regarding the care of these devices Daily Remove the air tubing by pulling on the finger grips on the cuff Hang it in a clean dry place until next USE Notes e Do not hang