Home
ResMed Sleep Apnea Machine 60561 User's Manual
Contents
1. RESMED Swift LT NASAL PILLOWS SYSTEM User Guide English RESMED Swift LT NASAL PILLOWS SYSTEM Thank you for choosing the Swift LT Intended Use The Swift LT channels airflow noninvasively to a patient from a positive airway pressure device such as a continuous positive airway pressure CPAP or bilevel system The Swift LT is e tobe used by adult patients gt 30 kg for whom positive airway pressure has been prescribed e intended for single patient re use in the home environment and multipatient re use in the hospital institutional environment Using the Swift LT When using the Swift LT with ResMed flow generators that have mask setting options if available select SWIFT otherwise select MIRAGE as the mask option For a full list of compatible devices for this mask see the Mask Device Compatibility List on www resmed com on the Products page under Service amp Support If you do not have Internet access please contact your ResMed representative Notes e The Swift LT is not compatible for use with the ResMed AutoSet CS 2 and VPAP Adapt SV devices e SmartStop may not operate effectively when using Swift LT with some flow generators that have this feature e f you experience nasal dryness or irritation use of a humidifier is recommended English Parts of the Swift LT amp Ordering Information Tube retainer 60586 _ O Top buckle 60579 1 60580 10
2. eucalyptus or essential oils bleach alcohol or products that smell strongly eg citrus to clean any of the system s components Residual vapours from these solutions can be inhaled if not rinsed thoroughly They may also damage the system causing cracks A CAUTION If any visible deterioration of a system component is apparent cracking crazing tears etc the component should be discarded and replaced Daily After Each Use Handwash the separated mask components excluding headgear by gently rubbing in warm approx 30 C water using mild soap or diluted dishwashing detergent for one minute Rinse all components well with drinking quality water and allow them to air dry out of direct sunlight Weekly Handwash the headgear and tube retainer in warm approx 30 C water using mild soap or diluted dishwashing detergent Rinse well and allow them to air dry out of direct sunlight Reprocessing your Swift LT between Patients The Nasal Pillows System should be reprocessed when used between patients Cleaning disinfection and sterilisation instructions are available from the ResMed website www resmed com masks sterilization If you do not have Internet access please contact your ResMed representative Storage Ensure that your Swift LT is thoroughly clean and dry before storing It for any length of time Store the mask in a cool dry place out of direct sunlight Disposal The Swift LT does not contain any hazardous
3. Back buckle E 60558 1 60559 10 Headgear assembly D Pillows 60571 S 60572 M 60573 L Complete system 60561 includes small medium and large pillows S Small M Medium L Large Fitting your Swift LT A Hold the pillows at Adjust top straps over Adjust each end of the your nose B pull the tightening may cause backstrap overtightening headgear over your head excess pressure on your may cause excess nose pressure on upper lip Rotate frame to adjust Connect the short tube The Swift LT is now fitted pillow angle to ensure it to the flow generator s air and ready for use Head sits comfortably tubing gear should sit midway between ear and eye Using Tube Retainer Optional 2 CN II d S N Push tube retainer into When using the tube If the mask pulls on your buckle Clip either short retainer the tubing can be nose increase length of tube or air tubing to tube positioned to either side of tube between mask and retainer your face or centred tube retainer 3 English Disassembling your Swift LT Detach air tubing from short tube frame Remove pillows from Remove elbow from frame frame Cleaning your Swift LT in the home Notes e The nasal pillows system and headgear should be cleaned by handwashing e The headgear may be washed without being disassembled A WARNING Do not use aromatic based solutions or scented oils eg
4. pillows system is too noisy System is assembled Reassemble the Swift LT Make sure the pillows are incorrectly fully inserted into the frame Before using your Swift LT A WARNINGS The vent holes must be kept clear The mask should not be used unless the CPAP system is turned on and operating properly Follow all precautions when using supplemental oxygen Oxygen flow must be turned off when the flow generator is not operating so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire At a fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration varies depending on the pressure settings patient breathing pattern mask point of application and leak rate The technical specifications of the mask are provided for your clinician to check that they are compatible with the flow generator If used outside specification or if used with incompatible devices the seal and comfort of the mask may not be effective optimum therapy may not be achieved and leak or variation in the rate of leak may affect the flow generator function Discontinue using the Swift LT if you have ANY adverse reaction to the use of the mask and consult your physician or sleep therapist As with all masks some rebreathing may occur at low CPAP pressures Refer to your flow generator manual for details on settings and operational information Remove all packaging before using the mask 7 Engli
5. port temperature 20 C to 60 C Storage and transport humidity up to 95 non condensing 380 mm H x 57 mm W x 62 mm D Mask fully assembled with short tube assembly no headgear Note The manufacturer reserves the right to change these specifications without notice Symbols N Caution consult accompanying documents Lot number Part number European Authorised Representative 4 Temperature limitation S Humidity limitation amp 9 Does not contain latex ud Manufacturer 44 Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Consumer Warranty ResMed acknowledges all consumer rights granted under the EU Directive 1999 44 EG and the respective national laws within the EU for products sold within the European Union English Manufacturer ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip Velcro is a registered trademark of Velcro Industries B V C 4 2011 ResMed Ltd 0123 608315 1 2011 10 SWIFT LT USER Global leaders in sleep and respiratory medicine 608315 www resmed com
6. sh e Using a mask may cause tooth gum or jaw soreness or aggravate an existing dental condition If symptoms occur consult your physician or dentist Technical specifications Note he mask system does not contain latex PVC or DEHP materials Pressure Flow Curve Vent Flow Rate L min Dead Space Information Standards Therapy Pressure Resistance Sound Environmental Conditions Gross Dimensions 8 Mask Pressure cm H O Note The mask contains passive venting that meets the requirements for protection against rebreathing as specified in ISO 17510 2 As a result of manufacturing variations the vent flow rate may vary Pressure Flow cm H O L min 4 20 8 29 12 37 16 43 10 12 14 16 18 20 20 49 Physical dead space is the empty volume of the mask to the end of the swivel Using the large cushions this is 94 mL CE designation in accordance with EC directive 93 42 EEC class Ila ISO 14971 ISO 13485 ISO 10993 1 and ISO 17510 2 4 to 20 cm H O Drop in pressure measured nominal at 50 L min 0 6 cm H O and at 100 L min 2 0cm H O DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with ISO 4871 The A weighted sound power level of the mask is 25 dBA with uncertainty 3 dBA The A weighted sound pressure level of the mask at a distance of 1 m is 17 dBA with uncertainty 3 dBA Operating temperature 5 C to 40 C Operating humidity 1596 9596 non condensing Storage and trans
7. substances and may be disposed of with your normal household refuse English Reassembling your Swift LT Insert elbow into frame Align pillows with frame Push pillows firmly into frame Ensure top and bottom retention tabs slot into place Check positioning markers _ Slide left and right headgear stability arms onto frame on pillows and headgear Ensure inner wall of pillows is in correct position are on the same side If not squeeze pillow sides to release inner walls Reassembling the headgear Lay out the headgear as A Thread the top straps A Thread both backstraps shown writing facing through the top buckle through the back buckle upwards then B back over to Velcro facing outwards secure then B fold back over to secure Troubleshooting Possible reason Solution Pillows won t seal properly are uncomfortable or cause red marks Pillows may have Carefully follow instructions in Fitting your Swift LT been fitted incorrectly Check headgear is not overtightened incorrectly adjusted or Check ResMed logo on top of pillows is facing the headgear is too tight outwards Inner wall position of one Squeeze pillow sides to release Inner wall The both pillows is incorrect correct position is shown in Reassembling your Swift LT Pillows are wrong size Talk to your clinician Pillows may be dirty Clean pillows according to instructions in Cleaning your Swift LT in the Home Nasal