Home
ResMed S8 User's Manual
Contents
1. Technical Specifications Limited Warranty N N O1 O1 OQ O N Y Ol Indications for Use S8 AutoSet Il The S8 AutoSet Il self adjusting sleep apnea system is indicated for the treatment of obstructive sleep apnea OSA in adult patients The S8 AutoSet Il self adjusting sleep apnea system has two treatment modes AutoSet and fixed pressure CPAP The S8 AutoSet ll system is intended for home and hospital use S8 Elite II The S8 Elite Il continuous positive airway pressure CPAP system is indicated for the treatment of obstructive sleep apnea OSA in adult patients The S8 Elite II CPAP system is intended for home and hospital use Contraindications Your S8 Series ll is not a life support device and may stop operating during power failure or certain fault conditions It should not be used by patients who are dependent on continuous therapy Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions severe bullous lung disease pneumothorax pathologically low blood pressure dehydration cerebrospinal fluid leak recent cranial surgery or trauma Adverse Effects Patients should report unusual chest pain severe headache or increased breathlessness to their prescribing physician An acute upper respiratory tract infection may require temporary discontinuation of treatme
2. cran LCD et clavier S lection du type de masque Pour assurer un fonctionnement correct de votre appareil avec votre masque vous devez s lectionner le type de masque qui correspond au masque que vous utilisez 1 Avec l cran RAMPE ou ATTENTE affich appuyez sur la touche c En mode CPAP le mot lt RAMPE est affich sur l cran d attente En mode AutoSet S8 AutoSet Il uniquement c est le mot ATTENTE qui est affich 2 Appuyez sur la touche jusqu ce que MASQUE s affiche 3 Appuyez sur la touche c pour modifier le r glage 4 Appuyez sur la touche ou jusqu ce que le r glage souhait s affiche 5 Appuyez sur la touche TY pour appliquer ce r glage Utilisation de la fonction d ajustement du masque Vous pouvez vous servir de la fonction d ajustement du masque de la S8 Il pour vous aider mettre votre masque correctement en place Cette fonction g n re une pression d air pendant trois minutes avant le d but du traitement pour permettre la v rification et l ajustement du masque dans le but de minimiser les fuites Remarque assurez vous que l option de masque s lectionn e l cran MASQUE correspond au masque que vous utilisez 1 Mettez votre masque comme indiqu dans son mode d emploi Installation de la S8 II Francais 3 2 Avec l cran RAMPE ou ATTENTE affich maintenez la touche enfonc e pendant au moins trois secondes jusqu ce que la pression d air d marre Votre a
3. exibida a mensagem de erro Verifique tubo Premir se o fez O tubo de ar est solto ou Verifique se o tubo de ar est conectado com firmeza obstru do sua m scara e sa da de ar na parte dianteira do S rie S8 Il Depois de verificar o tubo de ar pressione a tecla Iniciar Parar para reiniciar o aparelho Se isso n o limpar a mensagem desconecte o cabo de energia e em seguida volte a conect lo para reiniciar o dispositivo A mensagem a seguir exibida no visor LCD depois que voc tenta atualizar configura es ou copiar dados para o cart o de dados ERRO CART O Retirar cart o O cart o de dados n o foi Certifique se de inserir o cart o de dados na ranhura para inserido corretamente cart o de dados com a seta voltada para cima enquanto o dispositivo S rie S8 Il est ligado e sem administrar terapia em modo de espera O cart o de dados s foi Certifique se de que o cart o de dados foi inserido na introduzido parcialmente ranhura do m dulo at o final Voc pode ter removido o Reinsira o cart o de dados e espere at que a cart o de dados antes de as mensagem PAR MET SUCESSO Retirar cart o configura es terem sido apare a no visor LCD copiadas para o S rie S8 II O cart o n o um cart o de Use somente cart o de dados ResScan dados ResScan A mensagem a seguir exibida no visor LCD depois que voc tenta atualizar configura es ou copiar dados para o cart o de dados ER
4. e Courant pour la S8 Il avec l HumidAire 3i 100 240 V 50 60 Hz 110 V 400 Hz 2 5 A 140 VA 110 W consommation maximale de courant Puissance maximale instantan e 340 VA Veuillez vous r f rer au mode d emploi du convertisseur DC 12 pour les valeurs nominales de courant continu Utilisez uniquement le convertisseur DC 12 ResMed avec l entr e CC La consommation typique de courant 20 cm H 0 est 39 VA ou 20 7 W Francais 10 95 96 sans condensation b F 140 F 20 C 60 C 10 95 96 sans condensation iveau de la mer 8500 2591 m Le produit est conforme toutes les exigences de compatibilit lectromagn tique CEM conform ment CEI 60601 1 2 pour les environnements commerciaux r sidentiels et l industrie l g re Vous rouverez les tableaux de compatibilit lectromagn tique relatifs ces appareils sur le site www resmed com page Produits rubrique SAV et assistance Cliquez sur le fichier PDF de votre appareil Deux couches de mousse cellules ouvertes de polyester impr gn es de fibres polyester Plastique flexible longueur 6 6 2 m Le raccord conique 22 mm de sortie d air est conforme la norme EN 1281 1 Classe Il double isolation Type CF Le d bit recommand pour l oxyg ne suppl mentaire est 4 l min Thermoplastique ignifug Le niveau de pression acoustique est mesur moins de 24 2 dBA 10 cm H 0 et 3 3 36 1 m de distance
5. Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour ou de copier des donn es sur la carte de donn es ERREUR REGLAGES Retirez carte Erreur de donn es sur la carte Contactez votre clinicien imm diatement de donn es Le message suivant ne s affiche PAS sur l cran LCD apr s que vous avez essay de mettre les r glages jour l aide de la carte de donn es CHARG REUSSI Retirez carte Les r glages n ont pas t mis Contactez votre clinicien imm diatement jour Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour ou de copier des donn es sur la carte de donn es REGL INVALIDES Retirez carte Les donn es d identification de Contactez votre clinicien imm diatement la carte de donn es ne correspondent pas celles de votre appareil Caract ristiques Pression de fonctionnement Dimensions H x x P Poids Temp rature de fonctionnement Alimentation lectrique Humidit de fonctionnement Temp rature de stockage et de transport Humidit de stockage et de transport Altitude de fonctionnement Compatibilit lectromagn tique Filtre air Circuit respiratoire Sortie d air Classifications CEI 60601 1 Oxyg ne suppl mentaire Boitier Niveau de bruit 4 20 cm H 0 4 6 x 6 5 x 5 7 112 mm x 164 mm x 145 mm 3 1 Ib 1 4 kg 41 F 95 F 5 C 36 C
6. partir de l cran d attente RAMPE ou ATTENTE appuyez sur la touche L cran R GLAGES s affiche Modification des r glages de votre S8 II 7 Menu R glages Appuyez sur la touche dans le menu R glages pour acc der aux options de ce menu Dans le menu R glages vous pouvez modifier les param tres suivants Expiration Plus Relax EPR voir page 6 Type de masque voir page 3 Longueur de tuyau Faites d filer les options jusqu ce que LONG TUYAU s affiche puis appuyez sur la touche e Appuyez sur la touche ou jusqu ce que le r glage souhait s affiche Capot avant Vous pouvez configurer votre appareil pour une utilisation avec le capot avant Faites d filer les options jusqu ce que HUMID s affiche puis appuyez sur la touche E Appuyez sur la touche ou jusqu a ce que le r glage souhait s affiche SmartStart SmartStart permet votre appareil de d marrer automatiquement lorsque vous respirez dans le masque Faites d filer les options jusqu ce que SMARTSTART s affiche puis appuyez sur la touche c Appuyez sur la touche o pour faire passer l option sur ON ou OFF Alarme de fuite L alarme de fuite vous signale la pr sence d une fuite au masque lev e Faites d filer les options jusqu ce que ALARME FUITE s affiche puis appuyez sur la touche e Appuyez sur la touche ou pour faire passer l option sur ON ou OFF Menu R sultats Appuyez sur la touche dans le menu
7. AC Sortie d air Accessoires disponibles Humidificateur int gr Capot avant Circuit respiratoire 9 10 3 m Convertisseur DC 12 Housse de circuit respiratoire ResMed Masques Vous trouverez la liste des masques et de leurs r glages compatibles avec ces appareils sur le site www resmed com page Produits rubrique SAV et assistance Humidificateurs Vous trouverez la liste des humidificateurs compatibles avec les appareils ResMed sur le site www resmed com page Produits rubrique SAV et assistance Installation de la S8 II AVERTISSEMENT V rifier que le c ble d alimentation et la fiche sont en bon tat et que l quipement n est pas endommag Seulle circuit respiratoire ResMed peut tre utilis avec l appareil Les circuits respiratoires d un autre type risquent de modifier la pression recue et de r duire l efficacit du traitement L obstruction du circuit et ou de l entr e d air pendant le fonctionnement risque de causer une surchauffe de l appareil ATTENTION Veiller placer l appareil de telle mani re que personne ne puisse le faire tomber ou se prendre les pieds dans le c ble d alimentation Sil appareil est pos sur le sol veiller ce qu il le soit dans un endroit exempt de poussi re de literie de v tements ou de tout autre objet susceptible d obstruer l entr e d air V rifier que la zone autour de l appareil est propre et s che Connexion de l appareil
8. apn ia do sono S8 AutoSet Il com ajuste autom tico tem dois modos de tratamento AutoSet e CPAP de press o fixa O sistema S8 AutoSet Il se destina a uso domiciliar e hospitalar S8 Elite II O sistema de press o cont nua e positiva das vias respirat rias CPAP S8 Elite II indicado para o tratamento da apn ia obstrutiva do sono AOS em pacientes adultos O sistema CPAP S8 Elite II se destina a uso domiciliar e hospitalar Contra indica es Seu S rie S8 Il n o um dispositivo de suporte de vida e poder parar de funcionar devido a uma interrup o no fornecimento de energia ou no caso de certas condi es de falha O aparelho n o deve ser usado por pacientes que dependam de tratamento cont nuo A press o positiva das vias respirat rias poder ser contra indicada em certos pacientes que sofram das seguintes condi es doen a bolhosa do pulm o grave pneumot rax tens o arterial patologicamente baixa desidrata o fuga de l quido cerebrospinal trauma ou cirurgia craniana recente Efeitos adversos O m dico respons vel pelo tratamento deve ser informado caso o paciente sinta dores no peito incomuns fortes dores de cabe a ou agravamento da falta de ar Uma infec o aguda no trato respirat rio superior poder exigir a interrup o tempor ria do tratamento Os seguintes efeitos colaterais podem ocorrer durante o tratamento com o dispositivo CPAP ressecamento do nariz boca ou garga
9. fornecido ar fresco suficiente atrav s da m scara e o ar expirado pode ser novamente inalado A reinala o do ar expirado por alguns minutos pode em certas circunst ncias provocar asfixia Isso se aplica maioria dos modelos de dispositivos CPAP Em caso de falta de energia ou defeito no aparelho remova a m scara O dispositivo S rie S8 ll pode ser ajustado para administrar press es de at 20 cm H 0 No caso improv vel de certas condi es de avaria poss vel a administra o de press es de at 30 cm H50 Se este dispositivo for utilizado com oxig nio quando n o estiver em funcionamento o fluxo do g s dever ser desligado Caso tenha permanecido ligado desligue o dispositivo e aguarde 30 minutos antes de lig lo novamente Explica o quando o dispositivo CPAP n o se encontra em funcionamento e o fluxo de oxig nio mantido o g s fornecido ao tubo de ar pode se acumular no compartimento do dispositivo e gerar risco de inc ndio Isso se aplica maioria dos tipos de dispositivos CPAP O oxig nio favorece a combust o N o use oxig nio quando estiver fumando nem em presen a de chamas desguarnecidas Certifique se sempre de que o dispositivo est gerando fluxo de ar antes de ligar o fornecimento de oxig nio Desligue sempre o fornecimento de oxig nio antes de interromper o fluxo de ar do dispositivo Nota caso seja utilizado um fluxo de oxig nio suplementar constante a concentra o do oxig nio ins
10. il vous demande d utiliser la carte de donn es pour copier les donn es de votre S8 Il et de lui renvoyer la carte La carte de donn es est fournie dans un tui de protection Les donn es copi es sur une carte de donn es restent stock es et disponibles dans la S8 II Copie des donn es sur la carte de donn es 1 2 Mettez la S8 Il sous tension et attendez que l cran d attente Rampe ou Attente s affiche Tenez la carte de donn es avec la fl che dirig e vers le haut et ins rez la jusqu la but e dans la fente pr vue cet effet La copie des donn es d marre automatiquement Le message CARTE INSEREE Patientez SVP s affiche sur l cran LCD de la S8 Il pendant la copie des donn es La copie prend environ cing secondes Le message COPIE TERMINEE Retirez carte s affiche sur l cran LCD une fois que la copie est termin e Retirez la carte de donn es en la prenant par le bout qui d passe et en tirant La carte de donn es doit tre rang e dans son tui de protection lorsqu elle n est pas utilis e Retournez la carte dans son tui de protection votre clinicien en l envoyant dans une enveloppe postale Utilisation de la carte de donn es pour mettre les r glages jour Si votre clinicien vous a fourni une carte de donn es qui contient de nouveaux r glages pour votre appareil 1 Avec l appareil en mode d attente Rampe ou Attente ins rez la carte de donn es dans la fente de la
11. n fuga de l quido cefalorraqu deo cirug a o traumatismo craneanos recientes Efectos secundarios Los pacientes deben informar a su m dico tratante si tienen alg n dolor inusual en el pecho dolor de cabeza grave o mayor dificultad para respirar Una infecci n aguda en las v as respiratorias superiores puede requerir la suspensi n temporal del tratamiento Durante el curso del tratamiento con el equipo CPAP pueden aparecer los siguientes efectos colaterales Sequedad de la nariz boca o garganta epistaxis hinchaz n por aerofagia molestias sinusales o del o do irritaci n ocular erupciones cut neas Piezas del sistema S8 Serie Il El equipo S8 Serie II incluye los siguientes elementos Equipo S8 Serie II Cable de alimentaci n Bolso para viaje Tubo de aire de 2 m nmn Indicaciones de uso Espafiol Asa de transporte Visor Teclado Ranura para la tarjeta de datos CC CA Salida de aire Accesorios disponibles Humidificador integrado Cubierta delantera Tubo de aire de3m Transformador DC 12 Funda para el tubo ResMed Mascarillas Se puede hallar una lista de las mascarillas y sus configuraciones que son compatibles con estos equipos en el sitio web www resmed com en la secci n de servicio y asistencia que se halla dentro de la p gina de productos Humidificadores Se puede hallar una lista de los humidificadores que son compati
12. DC 12 converter is available as an optional accessory It is not supplied with all models The device should not be connected to both AC and DC power sources simultaneously Note The above are general warnings and cautions Specific warnings cautions and notes appear with the relevant instructions in this User Guide Troubleshooting English 17 18 Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period specified below from the date of purchase by the initial consumer This warranty is not transferable Product Warranty Period ResMed humidifiers ResControl ResLink ResTraxx 1 Year ResMed flow generators 2 Years Accessories mask systems including mask frame cushion 90 Days headgear and tubing Excludes single use devices Note Some models are not available in all regions f the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This Limited Warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs c any damage or contamination due to cigarette pipe cigar or other smoke d any damage caused by water being spilled on or into a flow
13. R sultats pour acc der aux options de ce menu Vous pouvez galement afficher le nombre total d heures de traitement HRS UTIL et le nombre de sessions dans une p riode d utilisation de la S8 II UTILIS Remarque votre clinicien a peut tre personnalis votre appareil de mani re ce quil affiche les Smart Data Contactez le pour de plus amples informations sur les Smart Data Menu Options Appuyez sur la touche Y dans le menu Options pour acc der aux options de ce menu Dans le menu Options vous pouvez modifier le param tre de langue Faites d filer les options jusqu ce que LANGUE s affiche puis appuyez sur la touche Appuyez sur la touche ou jusqu ce que le r glage souhait s affiche Menu Entretien Appuyez sur la touche dans le menu Entretien pour acc der aux options de ce menu Le menu Entretien vous permet d afficher les informations relatives l appareil Messages affich s sur l cran LCD de la S8 Il Votre clinicien a peut tre r gl votre S8 II pour qu elle vous rappelle des choses importantes comme le moment o vous devez remplacer votre masque le moment o vous devez ins rer votre carte de donn es si votre appareil prend la carte de donn es en charge etc Le message de rappel s affiche sur l cran LCD et peut tre lu m me lorsque l appareil ne d livre pas de traitement Le r tro clairage de l cran LCD clignote lorsqu un message s affiche Votre clinicien peut r
14. blanco La alimentaci n no est Verifique que el cable de alimentaci n est conectado y conectada que el interruptor de corriente en caso de haberlo est encendido El S8 Serie Il no proporciona suficiente aire Se est usando el per odo de Espere a que la presi n del aire haya aumentado o rampa o el per odo de modifique el per odo de rampa o adaptaci n adaptaci n El filtro de aire est sucio Cambie el filtro de aire El tubo de aire est torcido o Enderece o cambie el tubo roto El tubo de aire no est Revise el tubo de aire debidamente conectado La mascarilla y el arn s no Ajuste la posici n de la mascarilla y del arn s est n correctamente colocados Falta el tap n o los tapones del Vuelva a colocarlo s puerto de acceso de la mascarilla Tal vez se ha modificado la Hable con el m dico para que modifique la presi n presi n necesaria para el tratamiento El equipo no inicia el tratamiento cuando usted respira en la mascarilla aunque el m dico ha habilitado la funci n SmartStart El cable de alimentaci n no Conecte el cable de alimentaci n firmemente en ambos est debidamente conectado extremos El tomacorriente puede estar Pruebe con otro tomacorriente defectuoso El m dico ha activado la alerta P ngase en contacto con el m dico de fuga la funci n SmartStart ha quedado autom ticamente desactivada Est utilizando una mascarilla La funci n SmartStart no funciona
15. carte de donn es La mise jour des r glages commence automatiquement Le message CARTE INSEREE Patientez SVP s affiche sur l cran LCD pendant la mise jour La mise jour prend environ cinq secondes Le message CHARG REUSSI Retirez carte s affiche sur l cran LCD si la mise jour des r glages a r ussi Remarque ce message ne s affiche qu une seule fois Si vous ins rez la carte de donn es une nouvelle fois apr s avoir mis vos r glages jour il ne s affiche pas Retirez la carte de donn es de la S8 II La carte de donn es doit tre rang e dans son tui de protection lorsqu elle n est pas utilis e AVERTISSEMENT Si votre clinicien vous a demand d utiliser la carte de donn es pour mettre les r glages de votre appareil jour et si le message CHARG REUSSI ne s affiche pas contacter votre clinicien imm diatement Nettoyage et entretien AVERTISSEMENT Risque de chocs lectriques Ne pas immerger l appareil ni le cable d alimentation dans l eau Syst matiquement d brancher l appareil avant de le nettoyer et v rifier qu il est bien sec avant de le rebrancher ATTENTION Ne pas suspendre le circuit respiratoire la lumi re directe du soleil afin d viter qu il ne durcisse ou ne se fissure avec le temps Ne pas utiliser d eau de Javel de chlore d alcool ou de solutions parfum es ni de savons hydratants ou antibact riens ou d huiles parfum es pour le nettoyage du circ
16. con las mascarillas facial de ResMed faciales ya que la v lvula antiasfixia no permite que se genere la suficiente presi n al espirar La respiraci n no es lo Inhale y exhale profundamente a trav s de la mascarilla suficientemente profunda como para activar la funci n SmartStart Hay una fuga excesiva Ajuste la posici n de la mascarilla y del arn s Es posible que falten los tapones de los puertos de la mascarilla Vuelva a colocarlos Puede que el tubo de aire no est debidamente conectado Con ctelo firmemente en ambos extremos Puede que el tubo de aire est torcido o roto Enderece o cambie el tubo Aparece un mensaje de error en el visor ERROR SISTxxxx jLlamar servicio O Exxxx en el cual xxxx define un error Falla de un componente Registre el n mero de error y llame al servicio de asistencia Aparece un mensaje de error en el visor Revisar tubo Pulse c hecho El tubo de aire no est bien Verifique que el tubo de aire est firmemente conectado conectado o est obstruido a la mascarilla y a la salida de aire situada en la parte delantera del S8 Serie Il Una vez que haya verificado el tubo de aire pulse la tecla inicio detenci n para volver a poner en marcha el equipo Si esto no hace que el mensaje desaparezca desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nuevamente en marcha el equipo Cuando intenta actualizar la configuraci n del equipo o copiar informaci
17. conform ment ISO17510 1 Le fabricant se r serve le droit de modifier ces caract ristiques sans notification pr alable Symboles apparaissant sur l appareil A Attention veuillez consulter la documentation jointe Protection anti gouttes Y quipement de type CF 4 Tension potentiellement dangereuse El quipement de classe II Marche Arr t Strat gie de d pannage 17 AVERTISSEMENTS ET PR CAUTIONS D ORDRE L GENERAL Un avertissement vous met en garde contre le risque de blessure 18 Lire le manuel enti rement avant d utiliser la S8 II Les conseils donn s dans ce manuel ne remplacent pas les instructions du m decin traitant Un patient ne doit connecter aucun appareil au port de communication de donn es sauf si son prestataire de sant ou son m decin lui a demand de le faire Seuls les produits ResMed peuvent tre connect s au port de communication de donn es La connexion d autres appareils peut causer des blessures ou endommager la S8 Il La S8 Il doit tre utilis e avec les masques et raccords recommand s par ResMed un m decin o un kin sith rapeute respiratoire Le masque ne peut tre port que si la S8 Il est sous tension et si elle fonctionne correctement Les orifices de ventilation du masque ne doivent jamais tre obstru s Explication la S8 Il est con ue pour tre utilis e avec des masques ou raccords sp ciaux poss dant des orifices de vent
18. consumo m ximo de energia Consumo de energia m x instant neo lt 340 VA e Consulte as instru es do transformador DC 12 para informa es sobre classifica es CC Use somente o transformador DC 12 da ResMed para entrada CC e Consumo de energia t pico a 20 cm H20 de 39 VA ou 20 7 W 10 a 95 sem condensa o 20 C a 60 C 5 F a 140 F 10 a 95 sem condensa o N vel do mar at 2591m 8500 p s O produto encontra se em conformidade com todos os requisitos de compatibilidade eletromagn tica EMC de acordo com IEC60601 1 2 para reas residenciais comerciais e de ind stria leve As tabelas de compatibilidade eletromagn tica para estes dispositivos ResMed podem ser encontradas em www resmed com na p gina Products Produtos em Service and Support Servi o e Suporte Clique no arquivo PDF relativo ao seu dispositivo Duas camadas de fibra n o tecida de poli ster coligadas por p Pl stico flex vel 2 m 6 p s e 6 pol A sa da de ar c nica de 22 mm encontra se em conformidade com EN 1281 1 Classe Il isolamento duplo Tipo CF Fluxo de oxig nio suplementar m ximo recomendado 4 l min Termopl stico de engenharia retardador de chamas A press o do som irradiada medida a lt 24 2 dBA a 10 cm H20 e 1 m 3 p s e 3 36 pol segundo a norma ISO 17510 1 O fabricante reserva se o direito de alterar estas especificac es sem aviso pr vio S mbolos que s o apresentados no disposit
19. couvercle du logement du filtre air en place R parations Ce produit S8 AutoSet Il S8 Elite II doit tre inspect par un service technique agr ResMed cinq ans apr s la date de fabrication Avant cette date l appareil devrait assurer un fonctionnement fiable et s r condition qu il soit utilis et entretenu conform ment aux instructions fournies par ResMed Les informations concernant la garantie ResMed sont fournies avec l appareil lors de sa livraison initiale Comme avec tous les appareils lectriques si vous constatez un d faut quelconque vous devez faire v rifier l appareil par un service technique agr ResMed Si vous pensez que votre appareil ne fonctionne pas correctement voir Strat gie de d pannage page 14 Foire aux questions Quelle sensation est ce que je vais ressentir la premi re fois que je respirerai avec la S8 II Lors de la premi re utilisation de votre S8 Il il est possible que vous ressentiez une g ne lorsque vous respirez contre le d bit d air Ceci est normal Vous continuerez respirer normalement pendant que vous dormez Le param tre EPR peut galement am liorer le confort du traitement Prenez le temps de vous habituer cette nouvelle sensation Qu est ce que je dois faire si j ai besoin de me lever la nuit Si vous devez vous lever pendant la nuit retirez votre masque et arr tez l appareil N oubliez pas de remettre le masque et de red marrer l appareil lorsque vo
20. dico Nota o menu do AutoSet s est dispon vel no S8 AutoSet ll Para entrar no menu detalhado a partir da tela de espera SUBIDA ou ASSENT pressione C7 Altera o das configura es no dispositivo S8 II Portugu s 1 A tela do menu PAR METROS configura es apresentada Menu Par metros Selecione Y no menu Par metros para acessar as op es desse menu Voc pode usar o menu Par metros para alterar O Al vio de Press o Expirat ria APE consulte a p gina 6 O tipo de m scara consulte a p gina 3 O comprimento do tubo V at COMP TUBO e selecione Ra Pressione ou at ver a configura o desejada A tampa frontal Voc pode configurar seu dispositivo para usar o acess rio tampa frontal V at HUMID e selecione c Pressione ou at ver a configura o desejada O SmartStart O SmartStart ativa automaticamente o dispositivo quando voc respira pela m scara V at SMARTSTART e selecione Pressione ou para alterar a op o para LIGADO ou DESLIG Oalerta de fuga O alerta de fuga indica a presen a de uma fuga de ar grande na m scara V at ALERTA FUGA e selecione Pressione ou para alterar a op o para LIGADO ou DESLIG Menu Resultados Selecione no menu Resultados para acessar as op es desse menu Voc pode usar o menu Resultados para ver o n mero total de horas de tratamento USADO HRS e o n mero de sess es em que o S rie S8 Il foi usado num
21. dicos da companhia a rea que for usar se pretender utilizar o S rie S8 Il a bordo de uma aeronave O S rie S8 Il segue os requisitos de Classe B Parte 15 da FCC dos EUA Nota n o use o S rie S8 Il enquanto o avi o estiver decolando ou aterrissando Posso utilizar meu S rie S8 Il se n o houver energia de rede el trica CA dispon vel O transformador DC 12 est dispon vel para conectar o S rie S8 Il a uma fonte de alimenta o CC de 12 V ou 24 V Contate seu m dico para obter detalhes Perguntas frequentes Portugu s 13 14 Resolu o de problemas Se ocorrer um problema experimente as sugest es a seguir Se o problema n o puder ser resolvido contate o fornecedor do equipamento ou a ResMed N o tente abrir o dispositivo Problema Poss vel causa Solu o O visor n o funciona A unidade n o se encontra Verifique se o cabo de energia est conectado e se o conectada a uma fonte de interruptor de energia quando dispon vel est ligado energia O ar fornecido pelo dispositivo S rie S8 II insuficiente Tempo de rampa ou Aguarde o aumento da press o de ar ou ajuste o tempo acomoda o est em uso de rampa ou acomoda o O filtro de ar est sujo Substitua o filtro de ar O tubo de ar est dobrado ou Endireite ou substitua o tubo foi perfurado Tubo de ar conectado Verifique o tubo de ar incorretamente M scara e arn s n o foram Ajuste a posi o da m scara e do arn s posi
22. equipo o copiar informaci n a una tarjeta de datos aparece el siguiente mensaje en el visor CONFIG INVALIDA Quitar tarjeta Los datos de identificaci n en Comun quese inmediatamente con su m dico la tarjeta de datos no coinciden con los datos de identificaci n de su equipo Especificaciones t cnicas Limites de presi n de funcionamiento Dimensiones altura x ancho x profundidad Peso Temperatura de funcionamiento Fuente de alimentaci n Humedad de funcionamiento Temperatura de almacenamiento y transporte Humedad de almacenamiento y transporte Altitud de funcionamiento Compatibilidad electromagn tica Filtro de aire Tubo de aire Salida de aire Clasificaciones CEI 60601 1 Oxigeno suplementario Construcci n de la carcasa Nivel sonoro 4 a 20 cm H 0 112 mm x 164 mm x 145 mm 4 6 x 6 5 x 5 7 1 4 kg 3 1 Ib 5 C a 36 C 41 F a 95 F e Margen de entrada para el S8 Serie Il con HumidAire 3i 100 240 V 50 60 Hz 110 V 400 Hz 2 5 A 140 VA 110 W m ximo consumo de potencia M ximo consumo de potencia instant nea 340 VA Para obtener los valores de CC consulte las instrucciones del transformador DC 12 Para recibir alimentaci n de CC utilice nicamente el transformador DC 12 de ResMed Elconsumo de potencia habitual a 20 cm H 0 es 39 VA 6 20 7 W 10 9596 sin condensaci n 20 C a 60 C 5 F a 140 F 10 95 sin condensaci n Desde el nivel del mar
23. gler les rappels suivants sur votre cran LCD Message Description Action INSERER Peut s afficher si votre Ins rez votre carte de donn es et suivez les CARTE appareil prend la carte de instructions que votre clinicien vous a donn es en charge donn es Une fois que vous avez termin le message dispara t de l cran Vous pouvez aussi le faire dispara tre en appuyant sur la touche S Ok REMPLACE Peut s afficher lorsque votre Appuyez sur la touche Ok pour R MASQUE ic A a masque doit tre remplac effacer le message de l cran et remplacez votre masque par un neuf APPEL Peut s afficher pour vous Appuyez sur la touche Ok pour CLINICIEN rappeler de contacter votre effacer le message de l cran et contactez clinicien par exemple pour votre clinicien discuter de votre traitement REMPLACE Peut s afficher pour vous Appuyez sur la touche Ok pour R FILTRE rappeler de remplacer le filtre air de votre appareil effacer le message de l cran et remplacez le filtre air Messages affich s sur l cran LCD de la S8 II Francais 9 10 Message Description Action ENTRETIEN Peut s afficher pour vous Appuyez sur la touche gj Ok pour ECHU rappeler de retourner votre effacer le message de l cran et contactez appareil pour entretien votre clinicien Utilisation de la carte de donn es pour collecter des donn es Lorsque votre clinicien veut consulter les donn es de votre traitement
24. hacia el interior del generador de aire La garant a queda anulada si el producto se vende o revende fuera de la regi n en la que fue comprado originalmente Las reclamaciones de garant a en relaci n con productos defectuosos deben ser realizadas por el consumidor inicial en el punto de venta donde el producto fue comprado La presente garant a revoca cualquier otra garant a expresa o impl cita incluso cualquier garant a impl cita de comerciabilidad o idoneidad para un prop sito en particular Algunas regiones o estados no permiten limitaciones respecto de la duraci n de una garant a impl cita por lo que es posible que la limitaci n estipulada anteriormente no sea aplicable en su caso particular ResMed no ser responsable de ning n da o incidental o emergente reclamado por haber ocurrido como resultado de la venta instalaci n o utilizaci n de cualquier producto de ResMed Algunas regiones o estados no permiten la exclusi n o limitaci n de los da os incidentales o emergentes por lo que es posible que la limitaci n estipulada anteriormente no sea aplicable en su caso particular La presente garant a le otorga derechos legales espec ficos y es posible que usted tenga otros derechos que pueden variar de una regi n a otra Para obtener m s informaci n acerca de los derechos que le otorga la presente garant a p ngase en contacto con su distribuidor local de ResMed o con una oficina de ResMed R001 307 2 05 06 RESM
25. n a una tarjeta de datos aparece el siguiente mensaje en el visor ERROR TARJETA Quitar tarjeta La tarjeta de datos no se Verifique que est insertando la tarjeta de datos en la insert correctamente ranura para tarjeta de datos con la flecha hacia arriba y mientras el S8 Serie Il est encendido y sin suministrar tratamiento en modo de espera La tarjeta de datos se ha Verifique que la tarjeta de datos est insertada hasta el insertado s lo parcialmente fondo en la ranura correspondiente Soluci n de problemas Espa ol 15 16 Es posible que haya retirado la Vuelva a insertar la tarjeta de datos y espere a que tarjeta de datos antes de que aparezca el mensaje CONFIG CORRECTA Quitar la configuraci n se haya tarjeta en el visor copiado en el S8 Serie II La tarjeta no es una tarjeta de Utilice nicamente una tarjeta de datos ResScan datos ResScan Cuando intenta actualizar la configuraci n del equipo o copiar informaci n a una tarjeta de datos aparece el siguiente mensaje en el visor ERROR CONFIG Quitar tarjeta Hay un error en la informaci n Comun quese inmediatamente con su m dico contenida en la tarjeta de datos Luego de intentar actualizar la configuraci n por medio de una tarjeta de datos NO aparece el siguiente mensaje en el visor CONFIG CORRECTA Quitar tarjeta La configuraci n no se Comun quese inmediatamente con su m dico actualiz Cuando intenta actualizar la configuraci n del
26. operating properly When treatment begins if ramp is set the pressure increases from a low pressure to the prescribed treatment pressure over the set period Ramping is designed to help you adjust to an increase in pressure gradually and enhance your comfort Stopping Treatment To stop treatment at any time remove your mask and press e If your clinician has enabled SmartStart simply remove your mask and treatment will end Changing the Settings on your S8 Il Device You can change settings such as Ramp Time EPR Level on the S8 Il by using the keypad and LCD When the device is in standby mode you can display a series of screens a menu on the LCD screen in order to view and change the settings for a particular function The Standard Menu Your clinician will have enabled the menu on your S8 Series Il device The picture shows the standard menu in each mode CPAP WELCOME gt gt gt gt gt gt RAMP pc EPR LEVEL 1 change 4 exit USED HRS 08000 1 exit USAGE 1000 1068 exit MASK ULTRA change exit SW SX4800100 t exit AUTOSET WELCOME gt gt gt gt gt gt SETTLING 10min menu t EPR LEVEL 1 change 4 exit USED HRS 08000 1 exit USAGE 1000 1068 exit MASK ULTRA change 1 exit SW SX4800100 1 exit Only displayed if access set by clinician Note The AutoSet menu is available on the S8 AutoSet Il o
27. supuesto al igual que con cualquier equipo el ctrico si detecta alguna irregularidad deber tomar precauciones y hacer que un centro de servicio t cnico autorizado de ResMed revise el equipo Si considera que el equipo n o est funcionando correctamente consulte Soluci n de problemas en la p gina 14 Preguntas frecuentes Qu sensaci n se tiene al respirar con el S8 Serie II Puede ocurrir que la primera vez que utilice el S8 Serie ll se sienta inc modo por el hecho de respirar contra el flujo de aire Esto es normal Usted seguir respirando normalmente mientras duerme La configuraci n del APE tambi n puede ayudarlo a sentirse m s c modo T mese el tiempo necesario para adaptarse a esta nueva sensaci n Qu debo hacer si quiero levantarme por la noche Si tiene que levantarse por la noche quitese la mascarilla y detenga el tratamiento Siempre recuerde volver a iniciar el tratamiento y ponerse nuevamente la mascarilla al regresar a la cama Qu debo hacer si siento que hay fugas de aire por la mascarilla El tratamiento suministrado por el S8 Serie Il es m s eficaz cuando la mascarilla est bien colocada y resulta c moda Las fugas pueden perjudicar el tratamiento por lo que es importante eliminar todas las que pudieran surgir Por ejemplo intente solucionar el problema modificando la posici n de la mascarilla y ajustando las correas Si utiliza una mascarilla nasal intente mantener
28. these ResMed devices can be found on www resmed com on the Products page under Service and Support Click on the PDF file for your device Two layered powder bonded polyester non woven fibre Flexible plastic 6 6 2 m The 22 mm conical air outlet complies with EN 1281 1 IEC 60601 1 Classifications Class II double insulation Type CF Supplemental Oxygen Housing Construction Noise Level Recommended maximum supplemental oxygen flow 4 L min Flame retardant engineering thermoplastic Radiated sound pressure is measured at lt 24 2 dBA at 10 cm H 0 and 3 3 36 1 m according to IS017510 1 The manufacturer reserves the right to change these specifications without notice Symbols which appear on the device A Attention consult accompanying documents Drip proof 4 Dangerous voltage v Class Il equipment Start Stop Type CF equipment Troubleshooting 15 16 i GENERAL WARNINGS AND CAUTIONS A warning alerts you to possible injury Read the entire guide before using the S8 Series ll device The advice in this guide should not supersede instructions given by the prescribing physician A patient should not connect a device to the data communication port unless instructed to do so by their health care provider or physician Only ResMed products are designed to be connected to the data communication port Connecting other devices could result in injury or damage to the S8
29. toute pi ce Cette garantie limit e ne couvre pas a tout dommage r sultant d une utilisation incorrecte d un usage abusif ou d une modification ou transformation op r e sur le produit b les r parations et l entretien effectu s par tout service de r paration sans l autorisation expresse de ResMed c tout dommage ou contamination caus par de la fum e de cigarette de pipe de cigare ou autre d tout dommage caus par de l eau renvers e sur ou dans un appareil La garantie est annul e pour les produits vendus ou revendus dans un pays autre que celui o ils ont t achet s l origine Les r clamations au titre de la garantie pour les produits d fectueux doivent tre pr sent es au lieu d achat par le client initial Cette garantie remplace toute autre garantie expresse ou implicite y compris toute garantie implicite de qualit marchande ou d ad quation un usage particulier Certains pays ou tats n autorisent pas les limitations de dur e pour les garanties implicites il est donc possible que la limitation susmentionn e ne s applique pas votre cas ResMed ne peut tre tenue pour responsable de tout dommage accessoire ou indirect r sultant de la vente de l installation ou de l utilisation de tout produit ResMed Certains pays ou tats n autorisent ni l exclusion ni la limitation des dommages accessoires ou indirects il est donc possible que la limitation susmentionn e ne s applique pas votre ca
30. your clinician or equipment supplier for advice Can travel with the S8 Series II Your S8 Series Il has an internal power supply that enables it to operate in other countries It will operate on power supplies of 100 240V and 50 60Hz No special adjustment is necessary but you will require an approved power cord for the region in which you are using the device Your S8 Series II device automatically adjusts to changes in altitude up to 8500 2591 m Please consult the medical services department of your carrier if you intend to use your S8 Series Il on an aircraft The S8 Series Il complies with US FCC Part 15 Class B requirements Note Do not use your S8 Series II while the aircraft is taking off or landing Can use my S8 Series Il if mains AC power is not available A DC 12 converter is available to connect the S8 Series Il to a 12V or 24V DC power source Contact your clinician for details Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not attempt to open the device English Problem Possible Cause Solution No display Power is not connected Ensure the power cable is connected and the power switch if available is on Insufficient air delivered from S8 Series Il device Ramp or settling time is in use Wait for air pressure to build up or change ramp or Air filter is dirty Air tubing is kinked or punctur
31. 8000 salir HS USADO 08000 1 salir USO 000 1068 salir 1000 1068 salir MASC ULTRA cambiar VS SX4800100 f salir IASC ULTRA ambiar t salir salir VS SX4800100 1 salir Esta pantalla aparece nicamente si el m dico ha habilitado el acceso C mo modificar la configuraci n del equipo S8 II Espafiol 5 Nota El men AutoSet s lo est disponible en el equipo S8 AutoSet II Para ingresar al men est ndar desde la pantalla de espera RAMPA o ADAPTACI N oprima ES Puede utilizar este men para modificar La configuraci n del alivio de presi n espiratoria APE Su m dico tal vez haya configurado el equipo para que suministre APE Esto le puede ayudar a aliviar la incomodidad que pueda experimentar al espirar durante el tratamiento Hay cuatro valores APAG no se suministra APE 1 el APE m s bajo 2 y 3 el APE m s alto La pantalla NIVEL APE s lo aparece si su m dico ha habilitado el acceso a la configuraci n del APE Para modificar el nivel del APE seleccione c Oprima o hasta ver la configuraci n que desee El tipo de mascarilla consulte p gina 3 Tambi n puede ver la cantidad total de horas de tratamiento HS USADO la cantidad de sesiones en las que el S8 Serie Il se us durante un determinado periodo de tiempo USO y la versi n de software actual VER El men detallado El m dico puede haber habilitado el men detalla
32. ED Dispositivo S rie S8 II S3 AutoSet II S8 Elite Il DISPOSITIVOS DE PRESS O POSITIVA DAS VIAS RESPIRAT RIAS Manual do Usu rio Portugu s 2008 ResMed Ltd Somente Rx 338523 PoB 1 08 01 Portugu s Conte do Indica es de utiliza o S8 AutoSet ll S8 Elite Il Contra indica es Efeitos adversos Partes do sistema S rie S8 ll M scaras Umidificadores Prepara o e configura o do S rie S8 Il Conex o do dispositivo Sele o do tipo de m scara Utiliza o do recurso de ajuste da m scara In cio do tratamento Interrup o do tratamento Altera o das configura es no dispositivo S8 Il O menu padr o O menu detalhado Mensagens no visor LCD do S rie S8 Il Utiliza o do cart o de dados para coletar dados Copiar dados para o cart o de dados Limpeza e manuten o Diariamente Semanalmente Mensalmente Substitui o do filtro de ar Manuten o Perguntas freq entes Resolu o de problemas Especifica es t cnicas Garantia limitada NON N O15 Indica es de utiliza o S8 AutoSet Il O sistema de apn ia do sono S8 AutoSet Il com ajuste autom tico indicado para o tratamento da apn ia obstrutiva do sono AOS em pacientes adultos O sistema de
33. Humidificateurs Installation de la S8 Il Connexion de l appareil S lection du type de masque Utilisation de la fonction d ajustement du masque D marrage du traitement Arr t du traitement Modification des r glages de votre S8 Il Menu standard Menu d taill Messages affich s sur l cran LCD de la S8 II Utilisation de la carte de donn es pour collecter des donn es Copie des donn es sur la carte de donn es Nettoyage et entretien Quotidien Hebdomadaire Mensuel Remplacement du filtre air R parations rores oxen vr cerva xt ux v a as Foire aux questions Strat gie de d pannage Caract ristiques Garantie limit e NO NM O1 CO 0 N O1 Ol Usage pr vu S8 AutoSet Il La S8 AutoSet ll est un appareil autopilot pr vu pour le traitement du syndrome d apn es obstructives du sommeil SAOS chez l adulte La S8 AutoSet Il poss de deux modes de traitement AutoSet et CPAP pression fixe La S8 AutoSet Il est pr vue pour une utilisation domicile ou en milieu m dical S8 Elite Il L appareil de pression positive continue PPC S8 Elite Il est pr vu pour le traitement du syndrome d apn es obstructives du sommeil SAOS chez l adulte La S8 Elite Il est pr vue pour une utilisation domicile ou en milieu m dical Contre indi
34. P 1257663 JP 1266956 JP 1266957 JP 1267270 JP 1267271 NZ 405614 NZ 406923 NZ 406924 NZ 406925 NZ 406926 NZ 406927 NZ 406928 US D544598 US D553228 Others pending S8 S8 AutoSet S8 Elite and SmartStart are trademarks of ResMed Ltd and AutoSet and HumidAire are registered in U S Patent and Trademark Office 2008 ResMed Ltd 338523 1 08 01 RESMED S8 Series Il S8 AutoSet Il S8 Elite Il POSITIVE AIRWAY PRESSURE DEVICES User Guide English Rx Only 2008 ResMed Ltd 338523 Eng 1 08 01 English Contents Indications for Use S8 AutoSet ll S8 Elite Il ContralndIications s a Ee e e s d ee Adverse Effects M Me RAM ba tena Parts of the S8 Series Il system Masks Humidifiers Setting up the S8 Series Il Connecting the Device Selecting the Mask Type Using the Mask fitting Feature Starting Treatment Stopping Treatment Changing the Settings on your S8 Il Device The Standard Menu The Detailed Menu Messages on the S8 Series II LCD Using the Data Card to Collect Data Copy Data onto the Data Card Cleaning and Maintenance Daily Weekly Monthly Replacing the Air Filter SEMVICING i ooo apa AAA NO E Rr ERN Frequently Asked Questions Troubleshooting
35. RESMED S8 Series II S8 AutoSet Il S8 Elite II User Guide English e Fran ais e Espa ol e Portugu s Rx Only ResMed Ltd Manufacturer 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp US Designated Agent 14040 Danielson Street Poway CA 92064 6857 USA ResMed UK Ltd EU Authorized Representative 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK ResMed Offices Australia Austria Brazil China Finland France Germany Hong Kong India Japan Malaysia Netherlands Norway New Zealand Singapore Spain Sweden Switzerland UK USA see www resmed com for contact details Protected by patents AU 691200 AU 697652 AU 709279 AU 724589 AU 730844 AU 736723 AU 750095 AU 750761 AU 764761 AU 779327 AU 2002231456 CN 02804930 6 EP 0651971 EP 0661071 EP 0920845 EP 0934723 EP 1028769 EP 1126893 EP 1502618 EP 1144036 JP 3580776 JP 3778797 NZ 504595 US 5199424 US 5245995 US 5522382 US 5704345 US 6029665 US 6138675 US 6240921 US 6363933 US 6367474 US 6398739 US 6425395 US 6502572 US 6591834 US 6635021 US 6705315 US 6745768 US 6817361 US 6988498 US 7004908 US 7040317 US 7100608 US 7141021 Other patents pending Protected by design registrations AU 302180 AU 302181 AU 302182 AU 302183 AU 302184 AU 302185 AU 302186 CN 200430121212 2 CN 200430121213 7 CN 200430121211 8 CN 200430121214 1 CN 200430121215 6 CN 200430121216 0 CN 200430121217 5 EP 269436 HK 0412901 9 JP 1257662 J
36. RO PAR METROS Retirar cart o Existe um erro de dados no Entre imediatamente em contato com seu m dico cart o de dados A mensagem a seguir N O exibida no visor LCD depois que voc tenta atualizar as configura es usando o cart o de dados PAR MET SUCESSO Retirar cart o As configura es n o foram Entre imediatamente em contato com seu m dico atualizadas A mensagem a seguir exibida no visor LCD depois que voc tenta atualizar configura es ou copiar dados para o cart o de dados PAR ME INV LIDOS Retirar cart o Os detalhes de identifica o Entre imediatamente em contato com seu m dico no cart o de dados n o correspondem aos detalhes de identifica o no seu dispositivo Resolu o de problemas Portugu s 16 Especifica es t cnicas Faixa de press o operacional Dimens es A x L x P Peso Temperatura operacional Fornecimento de energia Umidade operacional Temperatura de armazenamento e transporte Umidade de armazenamento e transporte Altitude operacional Compatibilidade eletromagn tica Filtro de ar Tubo de ar Sa da de ar Classifica es IEC 60601 1 Oxig nio suplementar Constitui o do gabinete N vel de ru do 4 a 20 cm H 0 112 mm x 164 mm x 145 mm 4 6 pol x 6 5 pol x 5 7 pol 1 4 kg 3 1 lb 5 C a 36 C 41 F a 95 F e Faixa de entrada para S rie S8 Il com HumidAire 8i 100 240 V 50 60 Hz 110 V 400 Hz 2 5 A lt 140 VA 110 W
37. Series Il device The S8 Series Il device should be used with masks and connectors recommended by ResMed or by a physician or respiratory therapist mask should not be used unless the S8 Series Il device is turned on and operating properly The vent hole or holes associated with the mask should never be blocked Explanation The S8 Series ll device is intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask vent holes However when the device is not operating insufficient fresh air will be provided through the mask and the exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This applies to most models of CPAP devices In the event of power failure or machine malfunction remove the mask The S8 Series Il device can be set to deliver pressures up to 20 cm H 0 In the unlikely event of certain fault conditions pressures up to 30 cm H50 are possible If oxygen is used with this device the oxygen flow must be turned off when the device is not operating If oxygen has been left on turn off the device then wait 30 minutes before turning on the device Explanation When the CPAP device is not in operation and the oxygen flow is left on oxygen delivered into the air de
38. ado Volver a respirar aire exhalado durante m s de varios minutos puede en algunas circunstancias provocar asfixia Esto se aplica a la mayor a de los modelos de equipos CPAP Si se produce un corte de energ a o si el equipo est funcionando mal qu tese la mascarilla El equipo S8 Serie Il puede configurarse para suministrar presiones de hasta 20 cm H 0 En el caso improbable de que se produzcan ciertos desperfectos en el funcionamiento las presiones pueden alcanzar hasta 30 cm H 0 Sise utiliza ox geno con el equipo el flujo de ste debe apagarse cuando el equipo no est funcionando Si el ox geno qued activado apague el equipo y espere 30 minutos antes de encenderlo nuevamente Explicaci n Si el flujo de ox geno queda encendido cuando el equipo CPAP no est funcionando el ox geno suministrado al tubo de respiraci n puede acumularse dentro del equipo CPAP y generar un riesgo de incendio Esto se aplica a la mayor a de los tipos de equipos CPAP Elox geno favorece la combusti n y no debe utilizarse en presencia de una llama expuesta o si hay un cigarrillo encendido Siempre aseg rese de que el equipo est generando un flujo de aire antes de encender el suministro de ox geno Apague siempre el suministro de ox geno antes de detener el flujo de aire del equipo Es posible integrar puertos en la mascarilla o en los conectores pr ximos a la mascarilla Nota un caudal fijo de ox geno suple
39. ampa ou acomoda o Coloque a m scara deite se e posicione o tubo de ar de forma que possa se movimentar livremente para o caso de voc se virar durante o sono PRECAU O N o deixe uma extens o de tubo de ar longa sobre a cama O tubo pode se enroscar na sua cabe a ou no seu pesco o durante o sono 3 Para iniciar o tratamento pressione curser Se seu m dico tiver configurado o dispositivo para iniciar automaticamente o tratamento usando SmartStart o dispositivo come ar a funcionar quando voc respirar pela m scara 4 Coloque a m scara da forma descrita nas instru es do usu rio da m scara AVISO A m scara s deve ser usada com o dispositivo S rie S8 Il ligado e funcionando corretamente No in cio do tratamento se a rampa estiver ativada a press o subir durante o per odo definido de uma press o baixa at a press o de tratamento prescrita O processo de rampa foi concebido para ajud lo a se adaptar gradualmente ao aumento de press o aprimorando o conforto Interrup o do tratamento Para parar o tratamento a qualquer momento remova sua m scara e pressione START STOP Se a fun o SmartStart tiver sido ativada pelo m dico basta remover a m scara para interromper o tratamento Altera o das configura es no dispositivo S8 Il Voc pode alterar algumas configura es p ex tempo de rampa n vel de APE no S8 Il usando o teclado e o visor LCD Quando o dispositivo
40. ang L appareil ne d marre pas lorsque vous respirez dans le masque bien que votre clinicien ait activ SmartStart Le c ble d alimentation n est Branchez le c ble d alimentation correctement aux deux pas correctement branch extr mit s La prise de courant est peut Essayez une autre prise de courant tre d fectueuse l alarme de fuite a t activ e par votre clinicien SmartStart a donc t d sactiv e automatiquement Vous utilisez un masque facial ResMed La respiration n est pas assez profonde pour d clencher SmartStart Fuite excessive Composant d fectueux Affichage du message d erreur Le circuit respiratoire n est pas raccord correctement ou est bloqu Contactez votre clinicien SmartStart ne fonctionne pas avec un masque facial car le niveau de pression l expiration permis par la valve anti asphyxie n est pas suffisant Respirez profond ment dans le masque Fran ais Ajustez la position du masque et du harnais Remplacez les bouchons qui manquent ventuellement au niveau des ports du masque Le circuit respiratoire n est peut tre pas raccord correctement Raccordez le circuit respiratoire correctement aux deux extr mit s Le circuit respiratoire est peut tre entortill ou perc D sentortillez ou remplacez le circuit respiratoire Affichage du message d erreur ERR SYSTEME Appel SERVICE ou Exxxx o xxxx correspond un num ro d erreur Notez le
41. antalla de espera Rampa o Adaptaci n Tome la tarjeta de datos con la flecha mirando hacia arriba e ins rtela en la ranura de la tarjeta de datos hasta que no avance m s El copiado de la informaci n se inicia autom ticamente Mientras los datos se est n copiando aparecer el mensaje TARJ INSERTADA Espere en el visor del S8 Serie II El copiado tarda aproximadamente cinco segundos Una vez que ste haya finalizado en el visor aparecer el mensaje COPIA COMPLETA Quitar tarjeta Retire la tarjeta de datos tom ndola del extremo y tirando hacia fuera Cuando no la est utilizando guarde la tarjeta de datos en el desplegable de protecci n Para enviar la tarjeta al m dico col quela en el desplegable de protecci n y utilice un sobre postal Uso de la tarjeta de datos para actualizar la configuraci n Si el m dico le ha dado una tarjeta de datos con una nueva configuraci n para el equipo realice los siguientes pasos 1 2 Con el equipo en modo de espera Rampa o Adaptaci n inserte la tarjeta de datos en la ranura del m dulo para tarjeta de datos La actualizaci n se iniciar autom ticamente Durante la actualizaci n en el visor aparecer el mensaje TARJ INSERTADA Espere La actualizaci n tarda aproximadamente cinco segundos Si la configuraci n se actualiz correctamente en el visor aparecer el mensaje CONFIG CORRECTA Quitar tarjeta Nota Este mensaje aparece s lo una
42. ard Inserted Please Wait message is displayed on the S8 Series ll LCD while data is being copied Copying takes approximately five seconds The Copy Complete Remove Card message is displayed on the LCD when copying has finished Messages on the S8 Series II LCD English 3 Remove the Data Card by gripping the end of the Data Card and pulling it out 4 Store the Data Card in its protective folder when not in use 5 Return the card in its protective folder to your clinician using a postal envelope Using the Data Card to Update Settings If your clinician has provided a Data Card with new device settings 1 2 3 With the device in standby Ramp mode insert the Data Card into the Data Card slot Updating will start automatically The Card Inserted Please Wait message is displayed on the LCD while updating is in progress Updating takes approximately five seconds The Settings Success Remove Card message is displayed on the LCD if the settings were updated successfully Note This message only appears once If you re insert the Data Card after you have updated your settings this message is not displayed Remove the Data Card from the S8 Series II Store the Data Card in its protective folder when not in use WARNING If your clinician has told you to use this Data Card to update the settings on your device and the Settings Success message does not appear contact your clinician immediately Cleaning an
43. bles con los equipos de ResMed en el sitio web www resmed com en la secci n de servicio y asistencia que se halla dentro de la p gina de productos Instalaci n del equipo S8 Serie II ADVERTENCIA Aseg rese de que el cable de alimentaci n y la clavija est n en buenas condiciones y que el equipo no est da ado S lo deben usarse tubos de aire ResMed con el equipo Un tubo de aire diferente podr a modificar la presi n que de hecho recibe lo que reducir a la eficacia del tratamiento Obstruir el tubo o la entrada de aire mientras el equipo est funcionando podr a provocar un sobrecalentamiento PRECAUCI N Tenga cuidado de no colocar el equipo en un lugar donde pueda ser golpeado o donde alguien pueda tropezar con el cable de alimentaci n Sicoloca el equipo en el piso aseg rese de que no haya polvo en el rea y de que no haya ropa ropa de cama ni ning n otro objeto que pudiera bloquear la entrada de aire Aseg rese de que el rea alrededor del equipo est limpia y seca Conexi n del equipo Visor y teclado Selecci n del tipo de mascarilla Para asegurarse de que el equipo funcione de la manera deseada con la mascarilla que usted ha elegido debe seleccionar el tipo de mascarilla que est utilizando 1 Con la pantalla de RAMPA o ADAPTACI N en el visor oprima TS En el modo CPAP la pantalla de espera muestra la palabra RAMPA En el modo AutoSet s lo en el S8 AutoSet Il la pantalla
44. camente A mensagem CART O INSERI Aguarde p f ser apresentada no visor LCD do S rie S8 Il enquanto os dados s o copiados A c pia leva aproximadamente cinco segundos A mensagem C PIA COMPLET Retirar cart o ser apresentada no visor LCD quando os dados tiverem sido copiados Remova o cart o de dados segurando sua extremidade e puxando o para fora Guarde o cart o de dados no estojo de prote o quando n o estiver em uso Devolva o cart o no estojo de prote o ao seu m dico utilizando um envelope postal Utiliza o do cart o de dados para atualizar configura es Caso seu m dico tenha fornecido um cart o de dados com novas configura es para o dispositivo 1 2 3 Com o dispositivo no modo de espera Subida ou Assent insira o cart o de dados na ranhura do m dulo de cart o de dados A atualiza o ser iniciada automaticamente A mensagem CART O INSERI Aguarde p f ser apresentada no visor LCD durante a atualiza o A atualiza o leva aproximadamente cinco segundos A mensagem PAR MET SUCESSO Retirar cart o ser apresentada no visor LCD caso as configura es tenham sido atualizadas corretamente Nota essa mensagem ser apresentada uma s vez Se voc voltar a inserir o cart o de dados depois de atualizar as configura es essa mensagem n o ser exibida Remova o cart o de dados do S rie S8 II Guarde o cart o de dados no estojo de prote o quando n o estiver e
45. cations Votre S8 Il n est pas un appareil de suppl ance fonctionnelle et son fonctionnement peut tre interrompu en cas de coupure de l alimentation ou dans le cas d une panne Elle ne doit pas tre utilis e chez les patients dont le traitement ne peut pas tre interrompu Le traitement par pression positive est contre indiqu chez certains patients pr sentant l une des pathologies pr existantes suivantes affection pulmonaire bulleuse grave pneumothorax hypotension d shydratation fuite de liquide c phalo rachidien r cent traumatisme ou intervention chirurgicale cr nienne Effets secondaires Les patients doivent avertir leur m decin traitant en cas de douleurs thoraciques inhabituelles de maux de t te s v res ou d une dyspn e accrue Une infection aigu des voies a riennes sup rieures peut n cessiter l arr t temporaire du traitement Les effets secondaires suivants peuvent apparaitre au cours du traitement par PPC s cheresse nasale buccale ou de la gorge saignements de nez ballonnements g ne au niveau de l oreille ou des sinus irritation des yeux ryth mes cutan s Composants de la S8 Il Votre S8 Il se compose des l ments suivants S8ll e Cable d alimentation Sac de transport Circuit respiratoire 6 6 2 m Usage pr vu Fran ais 1 Poign e de transport cran Fente d insertion de la carte de donn es Clavier CC
46. cionados corretamente Falta m a s tampa s na s Volte a colocar a s tampa s porta s de acesso da m scara A press o necess ria para Entre em contato com seu m dico para ajustar a tratamento pode ter sido press o alterada O diapositivo n o come a a funcionar quando voc respira pela m scara embora o m dico tenha ativado o SmartStart O cabo de energia n o foi Conecte o cabo de energia firmemente nas duas conectado adequadamente extremidades A tomada de energia pode Experimente outra tomada estar com defeito O alerta de fuga foi ativado Contate seu m dico pelo m dico o SmartStart foi desativado automaticamente Utiliza o de uma m scara O SmartStart n o funciona com uma m scara facial pois facial ResMed a v lvula de anti asfixia n o permite press o suficientemente alta durante a expira o A respira o n o Respire profundamente atrav s da m scara suficientemente forte para ativar o SmartStart Fuga excessiva Ajuste a posi o da m scara e do arn s Recoloque as tampas se n o estiverem nas portas da m scara O tubo de ar pode n o ter sido conectado adequadamente Conecte o tubo de ar com firmeza em ambas as extremidades O tubo de ar pode estar dobrado ou perfurado Endireite ou substitua exibida a mensagem de erro ERRO SISTxxxx Chamar manut OU Exxxx onde xxxx define um erro Falha de componente Registre o n mero do erro e ligue para a assist ncia t cnica
47. d Maintenance WARNING Beware of electric shock Do not immerse the device or power cord in water Always unplug the device before cleaning and make sure it is dry before reconnecting CAUTION Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack Do not use bleach chlorine alcohol or aromatic based solutions moisturizing or antibacterial soaps or scented oils to clean the air tubing or the device These solutions may cause hardening and reduce the life of the product Daily Disconnect the air tubing and hang it in a clean dry place until next use Weekly 1 10 Remove the air tubing and wash it in warm water using mild detergent 2 Rinse thoroughly hang and allow to dry 3 Before next use reassemble the mask and headgear English 4 Reconnect the air tubing Monthly Clean the exterior of the S8 Series ll with a damp cloth and mild liquid soap Check the air filter for holes and blockage by dirt Replace it every six months or more often in a dusty environment Replacing the Air Filter CAUTION Do not wash the air filter The air filter is not washable or reusable The air filter cover protects the device in the event of accidental liquid spillage onto the device Ensure the air filter and air filter cover are fitted at all times 1 Remove the air filter cover at the back of the device Air filter cover 2 Remove and discard the old air filt
48. dans chaque mode MODE BIENVENUE BIENVENUE gt gt gt gt gt gt gt gt gt gt gt gt ATTENTE 10min CPAP RAMPE 10min y MODE AUTOSET NIVEAU EPR 1 changer NIVEAU EPR 1 E changer quit HRS UTIL 08000 quit UTILIS 1000 1068 1 quit MASQUE ULTRA changer quit LOG SX4800100 quit quit HRS UTIL 08000 quit UTILIS 1000 1068 quit MASQUE ULTRA changer 1 quit LOG SX4800100 t quit S affiche uniquement si l acc s a t activ par le clinicien Remarque le menu AutoSet est disponible uniquement sur la S8 AutoSet ll Pour ouvrir le menu standard partir de l cran d attente RAMPE ou ATTENTE appuyez sur la touche Modification des r glages de votre S8 II Fran ais 5 Dans ce menu vous pouvez modifier les param tres suivants Expiration Plus Relax EPR Votre clinicien peut avoir r gl votre appareil pour qu il d livre une EPR Cette fonction peut s av rer utile pour soulager toute g ne que vous pourriez ventuellement ressentir durant le traitement lorsque vous expirez Quatre r glages sont disponibles OFF pas d EPR 1 EPR l g re 2 et 3 EPR maximum L cran NIVEAU EPR ne s affiche que si votre clinicien a activ l acc s aux r glages d EPR Pour modifier le niveau d EPR appuyez sur la touche eh Appuyez sur ou jusqu ce que le r glage souhait s affiche Type de ma
49. de APE Para alterar o n vel de APE selecione El Pressione ou at ver a configurac o desejada O tipo de m scara consulte a p gina 3 Voc tamb m pode ver o n mero total de horas de tratamento USADO HRS o n mero de sess es em que o dispositivo S rie S8 Il foi usado num per odo de utiliza o USO e a atual vers o do software VS O menu detalhado Seu m dico pode ter ativado um menu detalhado no seu dispositivo S rie S8 Il A imagem mostra o menu detalhado em cada modo BEM VINDO BEM VINDO CPAP AUTOSET SUBIDA 10min ASSENT 10min menu i menu 1 E T CPAP AUTOSET PAR METROS entrar sair N VEL DE APE 1 N VEL DE APE 1 x alterar d sair alterar y sair M SCARA ULTRA MASCARA ULTRA alterar 1 sair alterar t sair J COMP TUBO 2m COMP TUBO 2m alterar 1 sair alterar 1 sair HUMID NENHUM HUMID NENHUM gt alterar 1 sair alterar 1 sair SMARTSTART LIG SMARTSTART LIG alterar 1 sair alterar 1 sair ALERTA FUGA DES ALERTA FUGA DES alterar t sair alterar 1 sair RESULTADOS entrar t sair USADO HRS 08000 i sair USO 1000 1068 1 sair SMART DATA entrar t sair OP ES entrar 1 sair x x SMART DATA AUTOVISUAL DES entrar sair alterar cancel IDIOMA PORTUGS alterar sair FERE MANUTEN O entrar f sair NS 12345678912 L sair PCB 123456789123 4567 1 sair VS SX4800100 T sair S exibida se o acesso for ativado pelo m
50. de espera muestra la palabra ADAPTACI N 2 Oprima hasta que aparezca la palabra MASC 3 Oprima S para modificar la configuraci n 4 Oprima o v jhasta ver la configuraci n que desee 5 Oprima para aplicar la configuraci n Uso de la funci n de ajuste de la mascarilla Puede usar la funci n de ajuste de la mascarilla de los equipos S8 Serie II para obtener un ajuste adecuado Esta funci n suministra presi n de aire durante un lapso de tres minutos antes de comenzar el tratamiento durante los cuales usted puede verificar y corregir el ajuste de la mascarilla a fin de minimizar las fugas Nota Verifique que la configuraci n de la mascarilla que aparece en la pantalla MASC coincida con la mascarilla que usted est usando 1 Col quese la mascarilla seg n las instrucciones para el usuario Instalaci n del equipo S8 Serie II Espa ol 3 2 Con la pantalla de RAMPA o ADAPTACI N en el visor mantenga presionada la tecla durante al menos 3 segundos hasta que comience el suministro de presi n El equipo aumentar la presi n hasta alcanzar la presi n de ajuste de la mascarilla y mantendr esta presi n durante tres minutos En el visor aparecer la informaci n que figura a continuaci n Dicha informaci n indica que la funci n de ajuste de la mascarilla est funcionando y tiene el siguiente significado es un ajuste excelente es un muy buen ajuste es un buen ajuste y sign
51. de m scara diferente Devo fazer algo de especial antes de colocar a m scara Antes de colocar a m scara lave o rosto para remover o excesso de oleosidade facial Isso permitir um melhor ajuste e prolongar a vida til da almofada da m scara N o use cremes hidratantes quando estiver usando uma m scara Sinto a minha boca seca durante o tratamento o que devo fazer Voc pode sentir um ressecamento no nariz na boca e ou na garganta no decorrer do tratamento especialmente durante o inverno Em muitos casos a utiliza o de um umidificador pode resolver o desconforto Contate seu m dico para mais informa es Meu nariz fica irritado durante o tratamento o que devo fazer Nas semanas iniciais do tratamento voc poder sentir vontade de espirrar e ou ter corrimento ou obstru o nasal Na maioria dos casos a irrita o nasal pode ser resolvida com um umidificador Entre em contato com seu m dico ou o fornecedor do equipamento para mais informa es Posso viajar com o S rie S8 II Seu S rie S8 Il tem uma fonte de energia interna que permite sua opera o em outros pa ses O dispositivo aceita fontes de alimenta o de 100 a 240 V e 50 a 60 Hz N o requer ajuste especial mas pode ser necess rio um cabo de energia aprovado para a regi o em que o dispositivo est sendo usado Seu S rie S8 Il se ajusta automaticamente a mudan as de altitude at 2 591 m 8 500 p s Consulte o departamento de servi os m
52. de reparo ou substitui o de um produto defeituoso no mbito da garantia devem ser feitos pelo consumidor original no local de compra Esta garantia substitui todas as outras expl citas ou impl citas incluindo qualquer garantia impl cita de comerciabilidade ou de adequabilidade para determinada utiliza o Algumas regi es ou estados n o permitem limita es de tempo sobre a dura o de uma garantia impl cita pelo que a limita o acima pode n o se aplicar ao seu caso A ResMed n o respons vel por quaisquer danos incidentais ou consequentes reivindicados como decorrentes da venda instala o ou uso de qualquer produto ResMed Algumas regi es ou estados n o permitem a exclus o ou limita o de danos incidentais ou consequentes pelo que a limita o acima pode n o se aplicar ao seu caso Esta garantia lhe concede direitos legais espec ficos e voc pode ainda ter outros direitos que variam de acordo com a regi o Para mais informa es sobre seus direitos de garantia entre em contato com o revendedor local da ResMed ou os escrit rios da ResMed R001 307 2 05 06 Garantia limitada Portugu s 20
53. devront tre prises lorsque la temp rature ambiante est sup rieure 90 F 32 C e Lors de l utilisation d une alimentation CC syst matiquement utiliser le convertisseur DC 12 ResMed Le convertisseur DC 12 est vendu comme accessoire optionnel Il n est pas fourni avec tous les mod les l appareil ne doit pas tre connect simultan ment une alimentation AC et une alimentation CC Remarque les avertissements et pr cautions pr c dents sont d ordre g n ral Les avertissements pr cautions et remarques sp cifiques sont donn s avec les instructions auxquelles ils se rapportent dans le Guide utilisateur Strat gie de d pannage Francais 19 Garantie limit e ResMed garantit votre produit ResMed contre tout d faut de mat riaux et de main d uvre pour la p riode sp cifi e ci apr s compter de la date d achat par e client d origine Cette garantie n est pas cessible Dur e de Produit e TR garantie Humidificateurs ResMed ResControl ResLink 1an ResTraxx Appareils de traitement ResMed 2 ans Accessoires masques y compris entourage rigide bulle 90 jours harnais et circuit respiratoire Les appareils usage unique sont exclus Remarque certains mod les ne sont pas disponibles dans tous les pays En cas de d faillance du produit dans des conditions normales d utilisation ResMed son enti re discr tion r pare ou remplace le produit d fectueux ou
54. do en el equipo S8 Serie Il La figura muestra el men detallado en cada uno de los modos BIENVENIDO BIENVENIDO es nee RAMPA 10min ADAPTACI N 10min men y men y CPAP AUTOSET AUTOSET PAR METROS intro y salir NIVEL APE 1 x NIVEL APE 1 cambiar salir cambiar salir MASC ULTRA MASC ULTRA cambia salir cambiar 1 salir LONG TUBO 2m cambiar 1 salir HUMID NINGUNO cambiar 1 salir LONG TUBO 2m cambiar salir HUMID NINGUNO cambiar 1 salir SMARTSTART ENCE SMARTSTART ENCE RESULTADOS intro 1 salir HS USADO 08000 salir USO 1000 1068 y 1 salir SMART DATA intro T salir OPCIONES intro 1 salir cambiar salir cambiar 1 salir E W ALERTA FUGA APAG ALERTA FUGA APAG cambiar f salir cambiar f salir SMART DATA intro VISUAL AUTO APAG x x mn cambiar A IDIOMA ESPANOL cambiar salir SERVICIO intro salir NS 12345678912 l salir PCB 123456789123 4567 salir VS SX4800100 1 salir Esta pantalla aparece nicamente si el m dico ha habilitado el acceso Nota El men AutoSet s lo est disponible en el equipo S8 AutoSet II C mo modificar la configuraci n del equipo S8 II Espa ol Para ingresar al men detallado desde la pantalla de espera RAMPA o ADAPTACI N oprima Aparec
55. e Check tube Key if done Air tubing is loose or blocked Check that the air tubing is connected securely to your mask and the air outlet to the front of the S8 Series II When you have checked the air tubing press the Start Stop key to restart the device If this does not clear the message disconnect the power cord and then reconnect it to restart the device The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Card Error Remove Card Data Card is not inserted Check that the patient is inserting the Data Card into the correctly Data Card module with the arrow facing up while the S8 Escape Il is switched on and not delivering therapy standby mode The Data Card is only partly Ensure that the Data Card is inserted into the Data Card inserted slot as far as it will go You may have removed the Reinsert the Data Card and wait for the settings Data Card before settings Success Remove Card message to appear on the were copied to the LCD S8 Escape ll The cardis not a ResScan Data Only use a ResScan Data Card Card The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Settings Error Remove Card There is a data error on the Contact your clinician immediately Data Card The following message is NOT displayed on the LCD after you try to update the settings using the Data Card Settings Success Remove Card The settings w
56. ed Air tubing not connected properly Mask and headgear not positioned correctly Cap s missing from access port on mask Pressure required for treatment may have changed Power cord not connected properly Power outlet may be faulty Leak Alert has been enabled by your clinician SmartStart automatically disabled Use of a ResMed Full Face mask Breath not deep enough to trigger SmartStart Excessive leak settling time Replace air filter Straighten or replace tubing Check air tubing Adjust position of mask and headgear Replace cap s See your clinician to adjust the pressure Device does not start when you breathe into the mask although your clinician has enabled SmartStart Connect power cord firmly at both ends Try another power outlet Contact your clinician SmartStart does not work with a full face mask as the anti asphyxia valve will not allow sufficiently high pressure on exhalation Take a deep breath in and out through the mask Adjust position of mask and headgear Replace caps if missing from ports on mask Air tubing may not be connected properly Connect firmly at both ends Air tubing may be kinked or punctured Straighten or replace Troubleshooting 13 14 Problem Possible Cause Solution Displays error message SYSTEM ERRxxxx Call Service or Exxxx where xxxx defines an error Component failure Record error number and call service Displays error messag
57. ensual Limpie el exterior de la unidad S8 Serie Il con un pa o h medo y un jab n l quido suave Examine el filtro de aire para verificar que no tenga agujeros ni est obstruido por suciedad Reempl celo cada seis meses o con mayor frecuencia si se usa en un entorno con mucho polvo Limpieza y mantenimiento Espa ol 12 C mo cambiar el filtro de aire PRECAUCI N No lave el filtro de aire El filtro de aire no es lavable ni reutilizable e La tapa del filtro de aire protege el equipo en caso de que accidentalmente se derrame l quido sobre l Aseg rese de que el filtro de aire y la tapa del filtro est n colocados en todo momento Retire la tapa del filtro de aire situada en la parte trasera del equipo Tapa del filtro de aire 2 Retire y deseche el filtro de aire usado S Inserte un filtro nuevo coloc ndolo con el lado pintado de azul hacia fuera del equipo 4 Vuelva a colocar la tapa del filtro de aire Mantenimient Este producto S8 AutoSet I O S8 Elite Il debe ser inspeccionado por un centro de servicio t cnico autorizado de ResMed 5 a os despu s de la fecha de fabricaci n Hasta ese momento el equ ipo est dise ado para funcionar de manera segura y confiable siempre que se use y se mantenga de acuerdo con las instrucciones suministradas por ResMed Al entregar un equipo nuevo se brinda informaci n acerca de la garant a correspondiente de ResMed Por
58. er S Inserta new filter with the blue tinted side facing out from the device 4 Replace the air filter cover Servicing This product S8 AutoSet Il S8 Elite Il should be inspected by an authorized ResMed service centre five years from the date of manufacture Prior to this the device is intended to provide safe and reliable operation provided that it is operated and maintained in accordance with the instructions provided by ResMed Applicable ResMed warranty details are provided with the device at the time of original supply Of course as with all electrical devices if any irregularity becomes apparent you should exercise caution and have the device inspected by an authorized ResMed service centre If you feel that your device is not performing properly see Troubleshooting on page 13 Replacing the Air Filter 11 12 Frequently Asked Questions How will it feel when am breathing with the S8 Series II When you first use your S8 Series Il you may feel uncomfortable breathing against the airflow This is normal You will continue to breathe normally while you sleep The EPR setting may also improve comfort Take time to adjust to this new sensation What do I do when I want to get up in the night If you need to get up during the night remove your mask and stop therapy Always remember to restart therapy and put your mask on when you return to bed What do I do if l feel air leaking out of the mask The S8 Series Il de
59. er la pantalla del men de PARAMETROS Men de parametros Para acceder a las opciones de este menu seleccione en el men de par metros Puede utilizar el men de par metros para modificar La configuraci n del alivio de presi n espiratoria APE consulte p gina 6 El tipo de mascarilla consulte p gina 3 La longitud del tubo Despl cese hasta LONG TUBO y seleccione Oprima o v hasta ver la configuraci n que desee Lacubierta delantera Puede configurar el equipo para utilizar la cubierta delantera Despl cese hasta HUMID y seleccione Oprima O hasta ver la configuraci n que desee La configuraci n de SmartStart SmartStart le permite al equipo iniciar el tratamiento autom ticamente cuando usted respira en la mascarilla Despl cese hasta SMARTSTART y seleccione c Oprima O para modificar la opci n a ENCE o APAG La configuraci n de la alerta de fuga La alerta de fuga avisa cuando se produce una fuga grave por la mascarilla Despl cese hasta ALERTA FUGA y seleccione E Oprima O para modificar la opci n a ENCE o APAG Men de resultados Para acceder a las opciones de este men seleccione en el menu de resultados Puede utilizar el menu de resultados para ver la cantidad total de horas de tratamiento HS USADO y la cantidad de sesiones en las que el S8 Serie Il se us durante un determinado periodo de tiempo USO Nota Es posible que el m dico haya programado el equipo para que mues
60. er m s asesoramiento comun quese con el m dico o proveedor de equipos Puedo viajar con el S8 Serie II El S8 Serie Il tiene una fuente de alimentaci n interna que le permite funcionar en otros pa ses Puede funcionar con fuentes de alimentaci n de 100 240 V y 50 60 Hz No es necesario hacer ninguna adaptaci n especial pero usted debe usar un cable de alimentaci n aprobado para la regi n en la que est usando el equipo El equipo S8 Serie Il se adapta autom ticamente a los cambios de altitud hasta los 2591 m 8500 pies Preguntas frecuentes Espa ol 14 Si tiene intenci n de usar el S8 Serie Il en un avi n consulte al departamento de servicios m dicos de la aerol nea El S8 Serie Il cumple con los requisitos de la Parte 15 Clase B de la FCC Comisi n Federal de Comunicaciones de EE UU Nota No use el S8 Serie ll cuando el avi n est despegando o aterrizando Puedo usar el S8 Serie Il donde no haya una red de distribuci n de energ a el ctrica CA Para conectar el S8 Serie Il a una fuente de alimentaci n de 12 6 24 V de CC existe un transformador DC 12 Para obtener m s informaci n comun quese con el m dico Soluci n de problemas Si surge alg n problema intente poner en pr ctica las sugerencias que figuran a continuaci n Si el problema no se resuelve p ngase en contacto con el proveedor del equipo o con ResMed No intente abrir el equipo Problema Causa posible Soluci n Pantalla en
61. ere not Contact your clinician immediately updated The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Settings Invalid Remove Card The identification details on Contact your clinician immediately the Data Card do not match the identification details on your device Technical Specifications Operating pressure range Dimensions H x W x D Weight Operating Temperature Power Supply Operating Humidity Storage and Transport Temperature Storage and Transport Humidity Operating Altitude Electromagnetic Compatibility Air Filter Air Tubing Air Outlet 4to 20 cm H20 4 6 x 6 5 x 5 7 112 mm x 164 mm x 145 mm 3 1 Ib 1 4 kg 41 F to 95 F 5 C to 36 C e Input range for S8 Series Il with HumidAire 3i 100 240V 50 60Hz 10V 400Hz 2 5A lt 140VA 110W maximum power consumption Instantaneous peak power consumption lt 340VA Refer to the DC 12 converter instructions for DC ratings Only use the ResMed DC 12 converter for DC input e Typical power consumption at 20 cm H 0 is 39VA or 20 7W English 10 95 non condensing B F to 140 F 20 C to 60 C 10 95 non condensing Sea level to 8500 2591 m Product complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 for residential commercial and light industry environments The electromagnetic compatibility tables for
62. est no modo de espera voc pode exibir uma s rie de telas um menu no visor LCD para visualizar e alterar as configura es de determinada fun o Altera o das configura es no dispositivo S8 Il Portugu s 5 O menu padr o Seu m dico j ter ativado o menu no seu dispositivo S rie S8 Il A imagem mostra o menu padr o em cada modo BEM VINDO gt gt gt gt gt gt SUBIDA 10min menu T N VEL DE APE 1 alterar L sair USADO HRS 08000 sair USO 1000 1068 t sair M SCARA ULTRA alterar 1 sair VS SX4800100 T BEM VINDO gt gt gt gt gt gt ASSENT 10min menu t N VEL DE APE 1 alterar y sair USADO HRS 08000 1 sair USO 1000 1068 1 sair M SCARA ULTRA alterar 1 sair VS SX4800100 sair S exibida se o acesso for ativado pelo m dico Nota o menu do AutoSet s est dispon vel no S8 AutoSet ll Para entrar no menu padr o a partir da tela de espera SUBIDA ou ASSENT pressione Voc pode usar esse menu para alterar O Al vio de Press o Expirat ria APE Seu m dico pode ter configurado o dispositivo para fornecer APE Esse recurso pode ser utilizado para reduzir eventuais desconfortos sentidos na expira o durante o tratamento H quatro op es DES sem APE 1 APE mais baixo 2 e 3 APE mais alto A tela N VEL DE APE s aparece se seu m dico tiver ativado o acesso s configura es
63. g n las instrucciones para el usuario ADVERTENCIA Las mascarillas no deben utilizarse a menos que el equipo S8 Serie Il est encendido y funcionando correctamente Cuando se inicia el tratamiento si se ha configurado un periodo de rampa la presi n se va incrementando durante el per odo configurado desde una presi n baja hasta la presi n de tratamiento establecida El per odo de rampa est dise ado para ayudarlo a adaptarse gradualmente al incremento de presi n y brindarle m s comodidad Detenci n del tratamiento Para detener el tratamiento en cualquier momento qu tese la mascarilla y oprima START STOP Si su m dico ha activado la funci n SmartStart simplemente quitese la mascarilla y el tratamiento se detendr C mo modificar la configuraci n del equipo S8 Il Usted puede modificar la configuraci n del S8 Il como por ei el per odo de rampa o el nivel de APE por medio del teclado y el visor Cuando el equipo est en modo de espera puede navegar por una serie de pantallas un men en el visor a efectos de ver y modificar la configuraci n de una funci n determinada El men est ndar El m dico habr habilitado el men en el equipo S8 Serie Il La figura muestra el men est ndar en cada uno de los modos BIENVENIDO crap po AUTOSET ADAPTACI N 10min men 1 RAMPA 10min men NIVEL APE 1 cambiar salir NIVEL APE 1 cambiar salir i S USADO 0
64. generator Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty is in lieu of all other express or implied warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office R001 307 2 05 06 RESMED S8 II S8 AutoSet II S8 Elite Il APPAREILS DE PPC Guide utilisateur Fran ais 2008 ResMed Ltd Sur prescription uniquement 338523 FrC 1 08 01 Fran ais Sommaire Usage pr vu S8 AutoSet ll S8 Elite Il Contre indications Effets secondaires Composants de la S8 ll Masques
65. hasta 2591 m 8500 El producto cumple con todos los requisitos correspondientes en materia de compatibilidad electromagn tica EMC por sus siglas en ingl s de acuerdo con la CEI 60601 1 2 para entornos residenciales comerciales y de industria ligera Se pueden hallar los cuadros de compatibilidad correspondientes a estos equipos de ResMed en el sitio web www resmed com en la secci n de servicio y asistencia que se halla dentro de la p gina de productos Haga clic en el archivo PDF correspondiente a su equipo Dos capas de fibra de poli ster no entrelazada con uni n de polvo Pl stico flexible 2 m 6 6 La salida de aire c nica de 22 mm cumple con la norma EN 1281 1 Clase Il doble aislamiento Tipo CF Caudal m ximo de ox geno suplementario recomendado 4 I m Termopl stico de ingenier a ign fuga La presi n ac stica radiada est medida a lt 24 2 dBA a 10 cm H 0 y 1 m 3 3 36 seg n la norma ISO 17510 1 Espa ol El fabricante se reserva el derecho de modificar las presentes especificaciones sin previo aviso S mbolos que aparecen en el producto A Atenci n consultar la documentaci n adjunta A prueba de goteo 4 Tensi n peligrosa n Equipo Clase Il Inicio detenci n v Equipo tipo CF Soluci n de problemas 17 7 ADVERTENCIAS Y PRECAUCIONES GENERALES Una advertencia alerta sobre la posibilidad de que se produzcan lesiones Lea el presente manual en su to
66. ifican que usted debe ajustar la mascarilla AJUS MASC sex excel 3 Aj stese la mascarilla la almohadilla y el arn s hasta lograr un ajuste firme y c modo Transcurridos 3 minutos la presi n volver a la presi n configurada y se iniciar el tratamiento Si no quisiera esperar tres minutos mantenga presionada la tecla durante al menos tres segundos y el tratamiento comenzar inmediatamente Si oprime la tecla durante menos de tres segundos la unidad volver al modo de espera se ver la pantalla de RAMPA o ADAPTACI N Inicio del tratamiento 1 Aseg rese de que la alimentaci n est encendida En el visor aparecer el nombre del producto durante un breve lapso de tiempo y luego la pantalla de espera mostrar la palabra RAMPA o ADAPTACI N Oprima o para incrementar o disminuir el per odo de rampa o adaptaci n 2 Col quese la mascarilla recu stese y acomode el tubo de aire de forma que ste pueda moverse libremente si usted se da vuelta mientras duerme PRECAUCI N No deje largos tramos del tubo de aire alrededor de la cabecera de la cama Podr a enrollarse alrededor de la cabeza o cuello mientras duerme 3 Para iniciar el tratamiento oprima meme Si el m dico ha configurado el equipo para que inicie el suministro de tratamiento de forma autom tica utilizando la funci n SmartStart M el equipo iniciar el tratamiento cuando usted respire en la mascarilla 4 Col quese la mascarilla se
67. ilation qui permettent l coulement continu de l air hors du masque Lorsque l appareil est sous tension et qu il fonctionne correctement de l air propre provenant de l appareil expulse l air expir via les orifices de ventilation du masque Cependant lorsque l appareil ne fonctionne pas le d bit d air propre d livr dans le masque est insuffisant et une r inhalation de l air expir peut se produire Si la r inhalation de l air expir dure plus de quelques minutes elle peut dans certains cas entrainer une suffocation Cela vaut pour la plupart des appareils de PPC En cas de coupure de courant ou de dysfonctionnement de l appareil retirer le masque La S8 Il peut tre r gl e pour d livrer des pressions pouvant aller jusqu 20 cm H50 Dans le cas peu probable d une panne les pressions peuvent s lever jusqu 30 cm H 0 Si de l oxyg ne est utilis avec cet appareil l alimentation en oxyg ne doit tre ferm e lorsque l appareil n est pas en mode de fonctionnement Si l alimentation en oxyg ne a t laiss e ouverte mettre l appareil hors tension puis attendre 30 minutes avant de le remettre sous tension Explication lorsque l appareil de PPC n est pas en marche et que l alimentation en oxyg ne n est pas coup e l oxyg ne d livr dans le circuit respiratoire peut s accumuler dans l appareil et cr er un risque d incendie Cela vaut pour la plupart des appareils de PPC l oxyg ne est inflammable Ne pas fumer
68. it change exit LEAK ALERT OFF LEAK ALERT OFF change exit change f exit RESULTS enter 1 exit USED HRS 08000 y exit USAGE 1000 1068 1 exit SMART DATA enter 1 exit OPTIONS x x enter 1 exit SMART DATA enter 1 exit AUTO APPEAR OFF change cancel LANG ENGLISH change f exit SERVICING enter f exit SN 12345678912 y exit PCB 123456789123 4567 exit SW SX4800100 1 exit Only displayed if access set by clinician Note The AutoSet menu is available on the S8 AutoSet Il only To enter the detailed menu from the standby RAMP or SETTLING screen press The SETTINGS menu screen is displayed Changing the Settings on your S8 II Device English 7 Settings Menu Select on the Settings menu to access the options in this menu You can use the Settings menu to change the Expiratory Pressure Relief EPR settings see page 6 Mask type see page 3 Tube length Scroll to TUBE LENGTH and select Press or until you see the setting that you require Front cap You can set up your device to use the front cap accessory Scroll to HUMID and select cT Press or until you see the setting that you require SmartStart settings SmartStart enables your device to start automatically when you breathe into the mask Scroll to SMARTSTART and select Press or to change the option to ON or OFF Leak alert settings Leak a
69. ivo A Atenc o consulte os documentos que acompanham o produto prova de respingos Y Equipamento tipo CF 4 Tens o perigosa Equipamento classe II Iniciar Parar i AVISOS E PRECAU ES GERAIS Um aviso alerta sobre a possibilidade de ferimentos Leia todo o manual antes de utilizar o dispositivo S rie S8 II As orienta es contidas neste manual n o substituem as instru es prescritas pelo m dico Os pacientes n o devem conectar dispositivos porta de comunica o de dados a menos que tenham sido orientados para isso pelo prestador de cuidados de sa de ou pelo m dico A porta de comunica o de dados s deve ser conectada a produtos ResMed A conex o de outros dispositivos pode provocar les es ou danos ao dispositivo S rie S8 II O S rie S8 Il deve ser usado com m scaras e conectores recomendados pela ResMed por um m dico ou terapeuta respirat rio S use a m scara se o dispositivo S rie S8 Il estiver ligado e funcionando adequadamente Os respiradouros associados m scara nunca devem ser obstru dos Explica o o S rie S8 Il deve ser utilizado com m scaras ou conectores especiais que tenham respiradouros permitindo a sa da cont nua de fluxo de ar da m scara Quando o dispositivo estiver ligado e funcionando corretamente o ar fresco do dispositivo elimina o ar expirado atrav s dos respiradouros Contudo quando o dispositivo n o est funcionando n o
70. la boca cerrada durante el tratamiento Las fugas de aire por la boca pueden reducir la eficacia del tratamiento Si las fugas por la boca resultaran ser un problema una mascarilla facial o una correa para el ment n podr an ser la soluci n Para obtener m s informaci n p ngase en contacto con el m dico o con el proveedor de equipos Si usa una mascarilla facial y tiene problemas para obtener un ajuste c modo comun quese con el m dico o con el proveedor del equipo Es probable que una mascarilla de tama o o estilo diferente sea mejor para usted Hay algo en especial que deba hacer antes de colocarme la mascarilla Antes de ponerse la mascarilla l vese la cara para quitar el exceso de grasa facial Esto har que la mascarilla se ajuste mejor y que la almohadilla dure m s No utilice cremas hidratantes cuando vaya a ponerse la mascarilla Se me reseca la boca durante el tratamiento qu puedo hacer Es posible que experimente sequedad de la nariz boca y o garganta durante el curso del tratamiento especialmente durante el invierno En muchos casos un humidificador puede resolver estas molestias P ngase en contacto con el m dico para que le recomiende qu hacer Se me irrita la nariz durante el tratamiento qu puedo hacer Durante las primeras semanas de tratamiento es posible que estornude y que le gotee o se le tape la nariz En muchos casos la irritaci n nasal se puede resolver usando un humidificador Para obten
71. lares aparecen en el presente manual del usuario junto a las instrucciones pertinentes Soluci n de problemas Espa ol 19 20 Garantia limitada ResMed garantiza que el producto ResMed que usted posee estar libre de todo defecto de material y mano de obra durante el plazo estipulado a continuaci n a partir de la fecha de adquisici n por parte del consumidor inicial Esta garant a no es transferible Plazo de la Producto P garant a Humidificadores ResMed ResControl ResLink 1 a o ResTraxx Generadores de aire ResMed 2 a os Accesorios sistemas de mascarilla incluye armaz n de la 90 dias mascarilla almohadilla arn s y tubos Los dispositivos descartables no estan incluidos Nota Algunos modelos no se encuentran disponibles en todas las regiones Si el producto falla en condiciones de utilizaci n normales ResMed reparar o reemplazar a opci n suya el producto defectuoso o cualquiera de sus componentes Esta garantia limitada no cubre a cualquier da o provocado por la utilizaci n indebida abuso modificaci n o alteraci n del producto b reparaciones llevadas a cabo por cualquier organizaci n dedicada a la reparaci n que no haya sido expresamente autorizada por ResMed para efectuar dichas reparaciones c cualquier da o o contaminaci n provocados por humo de cigarrillo pipa cigarro u otras fuentes de humo d cualquier da o provocado por derramar agua sobre o
72. lert indicates when a high mask leak is present Scrollto LEAK ALERT and select el Press or to change the option to ON or OFF Results Menu Select Y on the Results menu to access the options in this menu You can use the Results menu to view the total number of hours of treatment USED HRS and the number of sessions that the S8 AutoSet ll was used in a usage period USAGE Note Your clinician may have customized your device to display Smart Data Contact your clinician for further details about Smart Data Options Menu Select Y on the Options menu to access the options in this menu You can use the Options menu to change the language setting Scroll to LANG and select ken Press or until you see the setting that you require Servicing Menu Select Y on the Servicing menu to access the options in this menu You can use the Servicing menu to view the device system information Messages on the S8 Series Il LCD Your clinician may have set your S8 Series ll device to remind you about important events such as when to replace your mask when to insert your Data Card if your device is Data Card enabled and so on The reminder message is displayed on the LCD and is visible if the device is not delivering therapy The backlight on the LCD flashes when a message is displayed Your clinician can set any of the following reminders on your LCD Message Description Action INSERT May appear if your device is Insert your Data Card and follo
73. livers the most effective treatment when the mask is well fitted and comfortable Treatment can be affected by leaks so it is important to eliminate any leaks that may arise For example try repositioning the mask and adjusting the straps If you are using a nasal mask try to keep your mouth closed during treatment Air leaks from your mouth can decrease the effectiveness of your treatment If mouth leaks are a problem a full face mask or chin strap may help Contact your clinician or equipment supplier for further details If you are using a full face mask and you have problems trying to get a comfortable mask fit contact your clinician or equipment supplier You may benefit from a different size or style of mask Anything special should do before putting the mask on Before wearing your mask wash your face to remove excess facial oils This will allow a better fit and prolong the life of the mask cushion Do not use moisturizer when wearing a mask My mouth feels dry during treatment what can do You may experience dryness of the nose mouth and or throat during the course of treatment especially during winter In many cases a humidifier may resolve this discomfort Contact your clinician for advice My nose is irritated during treatment what can I do You may experience sneezing and or a runny or blocked nose during the first few weeks of treatment In many cases nasal irritation can be resolved with a humidifier Consult
74. livery tubing may accumulate within the CPAP machine enclosure and create a risk of fire This applies to most types of CPAP machines Oxygen supports combustion Oxygen should not be used while you are smoking or in the presence of an open flame Always ensure airflow is being generated by the device before the oxygen supply is turned on Always turn the oxygen supply off before stopping the airflow from the device Note At a fixed rate of supplemental oxygen flow the inhaled oxygen concentration varies depending on where the oxygen is introduced the pressure settings patient breathing pattern mask selection and leak rate Explosion hazard do not use in the vicinity of flammable anesthetics Do not open the S8 Series Il case There are no user serviceable parts inside Repairs and internal servicing should only be performed by an authorized service agent Ports may be incorporated into the mask or in connectors that are near the mask caution explains special measures for the safe and effective use of the device At low pressures the flow through the exhalation ports of your mask may not clear all exhaled gas from the tubing Some rebreathing may occur The airflow for breathing produced by this device can be as much as 11 F 6 C higher than the temperature of the room Caution should be exercised if the room temperature is warmer than 90 F 32 C When using DC power always use a ResMed DC 12 converter The
75. llowing displays on the LCD screen indicating that the mask fitting feature is operating where is an excellent fit is a very good fit is a good fit while and each require you to adjust your mask MASK FIT excelnt 3 Adjust your mask mask cushion and headgear until you have a secure and comfortable fit After three minutes the pressure reverts to the set pressure and treatment will begin If you do not wish to wait three minutes hold down for at least three seconds to start treatment immediately If you press for less than three seconds the unit will return to standby mode the RAMP or SETTLING screen Starting Treatment 1 Make sure the power is on The product name is displayed briefly on the screen then the standby screen displays RAMP or SETTLING Press or to increase or decrease the ramping or settling period 2 Fit mask lie down and arrange the air tubing so that it is free to move if you turn in your sleep CAUTION Do notleave long lengths of air tubing around the top of your bed They could twist around your head or neck while you are sleeping 3 Tostart treatment press If your clinician has set up the device to start delivering therapy automatically using SmartStart M your device will start when you breathe into your mask 4 Fityour mask as described in the mask user instructions WARNING A mask should not be used unless the S8 Series Il device is powered and
76. m uso AVISO Se seu m dico tiver dito a voc para usar esse cart o de dados para atualizar as configura es do dispositivo e a mensagem PAR MET SUCESSO n o for exibida contate o m dico imediatamente Limpeza e manuten o AVISO Cuidado com choques el tricos N o mergulhe o dispositivo nem o cabo de energia em gua Antes de limpar sempre remova o plugue de energia da tomada e antes de reconect lo certifique se de que est seco PRECAU O N o deixe o tubo de ar dependurado sob luz solar direta pois poder enrijecer com o tempo e rachar Ao limpar o tubo de ar e o dispositivo n o utilize solu es a base de alvejante cloro lcool ou subst ncias arom ticas nem sabonetes hidratantes ou bactericidas nem leos perfumados Essas solu es podem causar enrijecimento e reduzir a vida til do produto Diariamente Desconecte o tubo de ar e pendure o em local limpo e seco at a pr xima utiliza o Semanalmente 1 2 3 4 Remova o tubo de ar e lave o em gua morna usando detergente suave Enx g e bem e pendure para secar Antes da pr xima utiliza o monte novamente a m scara e o arn s Reconecte o tubo de ar Mensalmente Limpe o exterior do S rie S8 Il com um pano mido e detergente l quido suave Verifique se o filtro de ar n o est perfurado ou bloqueado por impurezas Substitua a cada seis meses ou em menos tempo no caso de ambientes empoeirados Substitui o d
77. mentario la concentraci n de ox geno inhalado variar seg n el punto por el cual ste se introduzca los par metros de presi n el ritmo respiratorio del paciente la selecci n de la mascarilla y el nivel de fuga Peligro de explosi n no utilizar cerca de anest sicos inflamables No abra la carcasa del S8 Serie Il No hay piezas dentro que el usuario pueda reparar Las reparaciones y el mantenimiento interno deben ser efectuados nicamente por un agente de servicio t cnico autorizado Una precauci n explica medidas especiales a tomar para el uso seguro y eficaz del equipo Si las presiones son bajas el flujo de aire a trav s de los puertos de espiraci n de la mascarilla puede no ser suficiente para eliminar del tubo todos los gases espirados Es posible que se vuelva a respirar parte del aire espirado El flujo de aire generado por este equipo para la respiraci n puede alcanzar una temperatura de hasta 6 C 11 F superior a la temperatura ambiente Hay que tomar precauciones si la temperatura ambiente es superior a 32 C 90 F Cuando utilice alimentaci n de CC use siempre el transformador DC 12 de ResMed El transformador DC 12 se puede obtener como accesorio opcional No se suministra con todos los modelos El equipo no debe conectarse a fuentes de alimentaci n de CA y de CC de modo simult neo Nota Las anteriores son advertencias y precauciones generales Las advertencias precauciones y notas particu
78. ni approcher de flamme nue de l appareil lors de l utilisation d oxyg ne Syst matiquement v rifier qu un d bit d air est g n r par l appareil avant d ouvrir l alimentation en oxyg ne Syst matiquement couper l alimentation en oxyg ne avant d arr ter le d bit d air de l appareil Des ports peuvent tre int gr s au masque ou des raccords proches du masque Remarque lorsque de l oxyg ne suppl mentaire est d livr un d bit fixe la concentration de l oxyg ne inhal varie en fonction du point d entr e de l oxyg ne des r glages de pression de la respiration du patient du masque s lectionn ainsi que du niveau de fuite Risque d explosion Ne pas utiliser l appareil proximit d anesth siques inflammables Ne pas ouvrir le bo tier de la S8 Il Il ne contient aucune pi ce pouvant tre entretenue par l utilisateur Les r parations et l entretien interne doivent tre effectu s par un technicien agr Une pr caution Attention explique des mesures particuli res permettant d assurer une utilisation efficace et s re de l appareil basses pressions le d bit aux orifices de ventilation de votre masque peut s av rer insuffisant pour expulser tous les gaz expir s hors du circuit respiratoire Une r inhalation peut se produire Latemp rature du d bit d air produit par cet appareil peut tre sup rieure de 11 F 6 C la temp rature ambiante Des pr cautions particuli res
79. nly To enter the standard menu from the standby RAMP or SETTLING screen press Sedi Changing the Settings on your S8 II Device English 5 You can use this menu to change the Expiratory Pressure Relief EPR settings Your clinician may have set up your device to deliver EPR This can be used to help ease any discomfort you may experience when breathing out during treatment There are four settings OFF no EPR 1 lowest EPR 2 and 3 highest EPR The EPR LEVEL screen only appears if your clinician has enabled access to the EPR settings To change the EPR level select Press or until you see the setting that you require Mask type see page 3 You can also view the total number of hours of treatment USED HRS the number of sessions that the S8 Series Il device was used in a usage period USAGE and the current software version SW The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series Il device The picture shows the detailed menu in each mode WELCOME CPAP AUTOSET RAMP 10min SETTLING 10min menu 1 menu 1 GSI CPAP AUTOSET SETTINGS enter exit EPR LEVEL 1 x EPR LEVEL 1 x change exit change exit MASK ULTRA MASK ULTRA change 1 exit change exit TUBE LENGTH 2m TUBE LENGTH 2m change exit change 1 exit HUMID NONE HUMID NONE change 1 exit change 1 exit SMARTSTART ON SMARTSTART ON change ex
80. nt The following side effects may arise during the course of therapy with the CPAP device drying of the nose mouth or throat nosebleed bloating earor sinus discomfort eye irritation skin rashes Parts of the S8 Series Il system Your S8 Series Il device comprises S8 Series Il device Power cord Carry bag 2m air tubing Indications for Use English 1 Carry handle Screen Keypad Data Card slot Air outlet DC AC Accessories available Integrated humidifier Front cap 8 mair tubing DC 12 converter ResMed Tubing Wrap Masks A list of masks and their settings compatible with these devices can be found on www resmed com on the Products page under Service and Support Humidifiers A list of humidifiers compatible with ResMed devices can be found on www resmed com on the Products page under Service and Support Setting up the S8 Series ll WARNING Make sure the power cord and plug are in good condition and the equipment is not damaged Only ResMed air tubing should be used with the device A different type of air tubing may alter the pressure you actually receive and reduce the effectiveness of your treatment Blocking the hose and or air inlet of the device while in operation could lead to overheating of the device CAUTION Becareful to place the device where it cannot be bumped and where no one will trip over the power cord f
81. nta sangramento nasal incha o e mal estar no ouvido ou seio nasal irrita o dos olhos urtic ria Indica es de utiliza o Portugu s Partes do sistema S rie S8 Il Seu dispositivo S rie S8 Il inclui os seguintes itens Dispositivo S rie S8 II Cabo de energia Bolsa de transporte Tubo de ar de 2 m Alca de transporte Ranhura do cart o de dados CC CA Sa da de ar Acess rios dispon veis Umidificador integrado Tampa frontal e Tubo de ar de 3 m Transformador DC 12 Envolt rio de tubo ResMed M scaras Visite a p gina Products Produtos em Service and Suport Servico e Suporte no endere o www resmed com para obter uma lista de m scaras e suas configura es compat veis com esses dispositivos Umidificadores Visite a p gina Products Produtos em Service and Suport Servi o e Suporte no endere o www resmed com para obter uma lista de umidificadores compat veis com dispositivos ResMed Prepara o e configura o do S rie S8 II AVISO Certifique se de que o cabo de energia e o plugue est o em boas condi es e que o equipamento n o se encontra danificado Use somente tubos de ar da ResMed com o dispositivo A utiliza o de tubos de ar diferentes pode alterar a press o recebida reduzindo a efic cia do tratamento A obstru o do tubo e ou entrada de ar do dispositivo durante seu funcionamento pode acarretar o su
82. num ro de l erreur et appelez le SAV V rifier tuyaux App s touche V rifiez que le circuit respiratoire est fermement raccord votre masque et la sortie d air l avant de la S8 Il Une fois que vous avez v rifi le circuit respiratoire appuyez sur la touche Marche Arr t pour red marrer l appareil Si le message ne disparait pas d branchez le c ble d alimentation et branchez le nouveau pour red marrer l appareil Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour ou de copier des donn es sur la carte de donn es ERREUR CARTE Retirez carte La carte de donn es n est pas correctement ins r e La carte de donn es est ins r e partiellement seulement Vous avez peut tre retir la carte de donn es avant que les r glages n aient t copi s sur la S8 Il La carte n est pas une carte de donn es ResScan V rifiez que vous ins rez bien la carte de donn es dans la fente de la carte de donn es avec la fl che dirig e vers le haut et lorsque la S8 Il est en marche mais qu elle ne d livre pas de traitement mode d attente V rifiez que la carte de donn es est ins r e jusqu la but e dans la fente pr vue cet effet Ins rez la carte de donn es nouveau et attendez que le message CHARG REUSSI Retirez carte s affiche sur l cran LCD Utilisez uniquement une carte de donn es ResScan Strat gie de d pannage 15 16
83. o Preguntas frecuentes Soluci n de problemas Especificaciones t cnicas Garantia limitada 0 00 000 cts N N 0d O1 O Co N N Indicaciones de uso S8 AutoSet Il El sistema de ajuste autom tico para la apnea del sue o S8 AutoSet Il est indicado para tratar la apnea obstructiva del sue o AOS en pacientes adultos El sistema de ajuste autom tico para la apnea del sue o S8 AutoSet Il ofrece dos modos de tratamiento el modo AutoSet y el modo de presi n fija CPAP El sistema S8 AutoSet ll est dise ado para uso hospitalario y domiciliario S8 Elite Il El sistema de presi n positiva continua en las vias respiratorias CPAP S8 Elite Il est indicado para tratar la apnea obstructiva del sue o AOS en pacientes adultos El sistema CPAP S8 Elite Il est dise ado para uso hospitalario y domiciliario Contraindicaciones El equipo S8 Serie II no es un equipo de apoyo vital y puede dejar de funcionar si hay un corte en el suministro de energ a o si se producen determinados desperfectos No debe ser utilizado en pacientes que requieran un tratamiento permanente El tratamiento con presi n positiva en las v as respiratorias puede estar contraindicado en algunos pacientes que presenten las siguientes afecciones previas enfermedad pulmonar bullosa grave neumot rax presi n arterial patol gicamente baja deshidrataci
84. o filtro de ar PRECAU O N o lave o filtro de ar O filtro de ar n o lav vel nem reutiliz vel Atampa do filtro de ar protege o dispositivo no caso de algum l quido ser acidentalmente derramado sobre o dispositivo Certifique se de que o filtro de ar e a tampa do filtro de ar estejam sempre instalados Limpeza e manuten o Portugu s 12 1 Remova a tampa do filtro de ar que se encontra na parte de tr s do dispositivo Tampa do filtro de ar 2 Remova e jogue fora o filtro de ar usado S Introduza um filtro novo com a face azul voltada para fora 4 Recoloque a tampa do filtro de ar Manuten o Este produto S8 AutoSet ll S8 Elite ll deve ser examinado por uma assist ncia t cnica autorizada da ResMed cinco anos ap s a data de fabrica o Antes disso o dispositivo deve proporcionar um funcionamento seguro e confi vel desde que utilizado e mantido segundo as instru es fornecidas pela ResMed Os detalhes da garantia ResMed aplic vel s o fornecidos com o dispositivo na compra original Como de h bito no caso de dispositivos el tricos se houver alguma irregularidade aparente seja prudente e encaminhe o aparelho para ser examinado por uma assist ncia t cnica autorizada da ResMed Se achar que seu dispositivo n o est funcionando adequadamente consulte Resolu o de problemas na p gina 14 Perguntas frequentes Como vou me sentir quando estiver respirando com o S rie S8 II Quando u
85. onfigura o na tela M SCARA a recomendada para a m scara em uso 1 Coloque a m scara da forma descrita nas instru es do usu rio da m scara 2 Quando a tela SUBIDA rampa ou ASSENT acomoda o estiver sendo exibida mantenha o bot o pressionado por pelo menos tr s segundos at iniciar o fornecimento do ar pressurizado O dispositivo aumentar a press o at atingir a press o de ajuste da m scara e a manter por tr s minutos Voc ver a imagem a seguir no visor LCD indicando que o recurso de ajuste da m scara est em funcionamento onde excelente ajuste ajuste muito bom bom ajuste enquanto e exigem um melhor ajuste da m scara AJU M SC excelnt Ajuste a m scara a almofada da m scara e o arn s at obter um posicionamento firme e confort vel Ap s tr s minutos a press o retorna press o definida e o tratamento iniciado Se n o quiser esperar tr s minutos mantenha o bot o pressionado por pelo menos tr s segundos para iniciar imediatamente o tratamento Se voc pressionar o bot o por menos de tr s segundos a unidade retornar ao modo de espera tela SUBIDA ou ASSENT In cio do tratamento 1 Certifique se de que a unidade se encontra ligada O nome do produto exibido rapidamente no visor Em seguida a tela de espera exibe SUBIDA rampa ou ASSENT acomoda o Pressione ou para aumentar ou reduzir o per odo de r
86. per odo de utiliza o USO Nota seu m dico pode ter personalizado o dispositivo para apresentar Smart Data Contate o m dico para obter mais informa es sobre Smart Data Menu Op es Selecione Y no menu Op es para acessar as op es desse menu Voc pode usar o menu Op es para alterar a configura o de idioma V at IDIOMA e selecione c Pressione ou at ver a configura o desejada Menu Manuten o Selecione Y no menu Manuten o para acessar as op es desse menu Voc pode usar o menu Manuten o para ver as informa es sobre o sistema do dispositivo Mensagens no visor LCD do S rie S8 II Seu m dico pode ter configurado o S rie S8 Il para lembr lo de eventos importantes como por exemplo quando substituir sua m scara quando inserir seu cart o de dados se seu dispositivo tiver sido habilitado para cart o de dados e assim por diante O lembrete exibido no visor LCD e ficar visivel se o dispositivo n o estiver administrando uma terapia A luz de fundo do visor LCD pisca quando uma mensagem apresentada Seu m dico pode definir os seguintes lembretes no visor LCD Mensagem Descri o A o INSERIR Poder ser apresentada se o Insira o cart o de dados e siga as instru es CART O dispositivo utilizar cart es de do seu m dico Feito isso a mensagem dados desaparecer do visor LCD Pressionando OK a mensagem tamb m sera removida SUBST Podera se
87. peraquecimento do aparelho PRECAU O Coloque o dispositivo em local seguro onde n o seja poss vel derrub lo acidentalmente nem trope ar no cabo de energia Se colocar o aparelho no ch o certifique se de que o local n o est empoeirado nem cont m roupa de cama pe as de vestu rio ou outros itens que possam obstruir a entrada de ar Certifique se de que a rea volta do dispositivo se encontra limpa e seca Conex o do dispositivo Visor LCD e teclado Sele o do tipo de m scara Para garantir que o dispositivo funcione conforme o previsto ser preciso selecionar o tipo de m scara em uso 1 Quando a tela SUBIDA rampa ou ASSENT acomoda o estiver sendo exibida pressione No modo CPAP a tela de espera exibe a palavra SUBIDA No modo AutoSet somente no S8 AutoSet II a tela de espera exibe ASSENT Pressione at aparecer M SCARA Pressione para alterar a configuracao Pressione ou at ver a configura o desejada ao A OO N Pressione para aplicar Prepara o e configura o do S rie S8 II Portugu s Utiliza o do recurso de ajuste da m scara Pode se usar o recurso de ajuste da m scara do dispositivo S rie S8 Il para auxiliar na coloca o da m scara Esse recurso fornece ar pressurizado por tr s minutos antes do in cio do tratamento para que voc possa verificar e ajustar a coloca o da m scara de modo a minimizar fugas Nota Verifique se a c
88. pirado variar segundo o local de introdu o do g s as configura es de press o o padr o respirat rio do paciente o tipo de m scara e o ndice de fuga Risco de explos o n o use na proximidade de anest sicos inflam veis Portas podem ser incorporadas m scara ou a conectores que estejam pr ximos da m scara Resolu o de problemas Portugu s 18 N o abra o gabinete do S rie S8 Il N o existem pe as dentro do aparelho que possam ser reparadas pelo usu rio A manutenc o e os reparos internos s devem ser realizados por t cnicos autorizados Uma precau o explica cuidados especiais para uma utiliza o segura e eficaz do dispositivo A baixas press es o fluxo atrav s das portas de exalac o da m scara poder n o eliminar do tubo todo o g s expirado Poder ocorrer alguma reinala o O fluxo de ar para respira o produzido por este dispositivo poder estar 6 C 11 F acima da temperatura ambiente Tome cuidado no caso de a temperatura ambiente estar acima de 32 C 90 F Quando usar alimenta o CC use sempre um transformador DC 12 da ResMed O transformador DC 12 encontra se dispon vel como acess rio opcional N o fornecido com todos os modelos Este dispositivo n o deve ser conectado a fontes de energia CA e CC simultaneamente Nota os avisos e precau es acima s o de cunho geral Avisos precau es e notas espec ficas aparecer o junto s instru es
89. ppareil augmente progressivement la pression jusqu la pression d ajustement du masque qu il maintient pendant trois minutes Un message s affiche sur l cran LCD pour vous indiquer la qualit de l ajustement savoir excellent ajustement bon ajustement _ bon ajustement tandis que et signifient que vous devez ajuster votre masque AJUS MSQ lt excel 3 Ajustez votre masque la bulle du masque et le harnais jusqu ce que le masque soit la fois stable et confortable Au bout de trois minutes la pression r gl e est restaur e et le traitement commence Si vous ne voulez pas attendre trois minutes maintenez la touche enfonc e pendant au moins trois secondes pour d marrer le traitement imm diatement Si vous appuyez sur la touche pendant moins de 3 secondes l appareil retourne en mode d attente l cran RAMPE ou ATTENTE s affiche D marrage du traitement 1 V rifiez que l appareil est sous tension Le nom du produit s affiche bri vement sur l cran LCD apr s quoi l cran RAMPE ou ATTENTE s affiche Appuyez sur la touche ou pour augmenter ou r duire la dur e de rampe ou le temps d attente 2 Mettez le masque allongez vous et placez le circuit respiratoire de mani re ce qu il puisse suivre vos mouvements pendant que vous dormez ATTENTION Ne pas laisser de longueurs inutiles de tuyau en haut du lit Elles risqueraient de s enrouler autour de votre t te ou de
90. que je peux faire Il est possible que vous souffriez de s cheresse nasale buccale et ou de la gorge pendant le traitement notamment pendant les mois d hiver Dans de nombreux cas l utilisation d un humidificateur permet de pallier ce probl me Contactez votre clinicien pour plus de d tails J ai le nez irrit pendant le traitement Qu est ce que je peux faire ll est possible que vous ternuiez et ou que votre nez coule ou se bouche lors des premi res semaines de traitement Dans de nombreux cas ces sympt mes d irritation nasale peuvent tre limin s l aide d un humidificateur Consultez votre clinicien ou votre prestataire de sant pour plus de d tails Est ce que je peux emporter la S8 Il avec moi en voyage Votre S8 Il est quip e d une carte d alimentation qui lui permet de fonctionner dans diff rents pays Elle peut fonctionner avec des courants de 100 240 V et 50 60 Hz Foire aux questions Francais 13 14 Aucun r glage sp cial n est requis mais vous aurez besoin d un c ble d alimentation homologu pour le pays o vous voulez utiliser l appareil Votre S8 Il compense automatiquement les variations d altitude jusqu 8500 2591 m Veuillez consulter le service m dical de votre compagnie a rienne si vous souhaitez utiliser votre S8 Il bord d un avion La S8 Il est conforme aux r glements de la FCC USA Partie 15 normes applicables aux quipements de Classe B Remarque n utilise
91. r apresentada Pressione OK para remover a MASCARA quando for hora de substituir mensagem do visor LCD e substitua a a mascara mascara por uma nova CHAMAR Poder ser apresentada para Pressione Y OK para remover a SERVIDOR lembr lo de entrar em mensagem do visor LCD e contate o m dico contato com seu m dico p ex para falar acerca do progresso do tratamento SUBSTI Poder ser apresentada para Pressione a tecla OK para remover a FILTRO lembr lo de substituir o filtro mensagem do visor LCD e substitua o filtro de ar do dispositivo MANUTEN Poder ser apresentada para Pressione Y OK para remover a O lembr lo de levar o dispositivo para manuten o mensagem do visor LCD e contate o m dico Mensagens no visor LCD do S rie S8 II Portugu s 10 Utiliza o do cart o de dados para coletar dados Se seu m dico precisar fazer uma avalia o do tratamento ele pedir que use o cart o de dados para copiar os dados do S rie S8 Il e que envie o cart o para ele O cart o de dados ser fornecido em um estojo de prote o Os dados copiados para um cart o de dados continuam armazenados e dispon veis no dispositivo S rie S8 II Copiar dados para o cart o de dados 1 2 4 5 Ligue o S rie S8 Il e aguarde at ver a tela de espera Subida ou Assent Segure o cart o de dados com a seta voltada para cima e insira o na ranhura apropriada at o final A c pia dos dados tem in cio automati
92. relevantes neste manual Garantia limitada A ResMed garante que seu produto ResMed est livre de defeitos materiais e de m o de obra durante o per odo de tempo abaixo especificado a partir da data de compra pelo consumidor original Esta garantia n o transfer vel Per odo d Produto pits a garantia Umidificadores da ResMed ResControl ResLink 1 Ano ResTraxx Geradores de fluxo da ResMed 2 Anos Acess rios sistemas de m scara incluindo arma o da 90 Dias m scara almofada arn s e tubo Exceto dispositivos de utiliza o nica Nota Alguns modelos n o se encontram dispon veis em todas as regi es Se o produto apresentar defeito em condi es normais de utiliza o a ResMed efetuar a seu crit rio o reparo ou a substitui o do produto defeituoso ou de qualquer um de seus componentes Esta Garantia Limitada n o cobre a qualquer dano provocado por uso incorreto uso abusivo modifica o ou altera o do produto b consertos efetuados por empresas de assist ncia t cnica que n o tenham sido expressamente autorizadas pela ResMed para efetuar tais reparos c qualquer dano ou contamina o provocado a por fuma a de cigarro cachimbo charuto ou outras fontes d qualquer dano provocado pelo derrame de gua sobre ou dentro do gerador de fluxo A garantia deixa de ser v lida se o produto for vendido ou revendido fora da regi o da compra original Os pedidos
93. s Cette garantie vous octroie des droits reconnus par la loi et vous pouvez galement avoir d autres droits qui varient en fonction du pays o vous habitez Pour de plus amples informations sur vos droits de garantie veuillez contacter votre prestataire de sant ou ResMed R001 307 2 05 06 RESMED S8 Serie II S8 AutoSet II S8 Elite II EQUIPOS DE PRESI N POSITIVA EN LAS V AS RESPIRATORIAS Manual del usuario Espa ol Solo Rx 2008 ResMed Ltd 338523 SpL 1 08 01 Espa ol indice general Indicaciones de uso S8 AutoSet II S8 Elite Il Contraindicaciones Efectos secundarios Piezas del sistema S8 Serie Il Mascarillas Humidificadores Instalaci n del equipo S8 Serie Il Conexi n del equipo Selecci n del tipo de mascarilla Uso de la funci n de ajuste de la mascarilla Inicio del tratamiento Detenci n del tratamiento C mo modificar la configuraci n del equipo S8 Il El men est ndar El men detallado Mensajes en el visor del S8 Serie Il Uso de la tarjeta de datos para recoger informaci n C mo copiar informaci n a la tarjeta de datos Limpieza y mantenimiento Limpieza diaria Limpieza semanal Limpieza mensual C mo cambiar el filtro de aire Mantenimient
94. sque voir page 3 Vous pouvez galement afficher le nombre total d heures de traitement HRS UTIL le nombre de sessions dans la p riode d utilisation de la S8 II UTILIS et la version du logiciel actuellement install sur votre appareil LOG Menu d taill Votre clinicien peut aussi avoir activ un menu d taill sur votre S8 II La figure suivante repr sente le menu d taill dans chaque mode MODE CPAP MODE AUTOSET RAMPE 10min ATTENTE 10min menu 4 menu y poa On c CV E MODE CPAP MODE AUTOSET LL R GLAGES entr e 1 quit NIVEAU EPR 1 x NIVEAU EPR 1 x changer quit changer quit MASQUE ULTRA MASQUE ULTRA changer 1 quit changer 1 quit LONG TUYAU 2m LONG TUYAU 2m changer 1 su changer quit HUMID AUCUN HUMID AUCUN changer quit changer quit SMARTSTART ON SMARTSTART ON changer 1 quit changer 1 quit ALARME FUITE OFF ALARME FUITE OFF changer quit changer 1 quit R SULTATS entr e y quit HRS UTIL 08000 4 quit UTILIS 1000 1068 1 quit SMART DATA entr e 1 quit OPTIONS entr e 1 quit SMART DATA AFFIC AUTO OFF entr e y quit changer annuler LANGUE FRANC changer f quit ENTRETIEN entr e quit NS 12345678912 y quit PCB 123456789123 4567 1 quit LOG SX4800100 quit S affiche uniquement si l acc s a t activ par le clinicien Remarque le menu AutoSet est disponible uniquement sur la S8 AutoSet ll Pour ouvrir le menu d taill
95. talidad antes de usar el equipo S8 Serie II Las recomendaciones que figuran en el presente manual no deben sustituir las instrucciones brindadas por el m dico tratante El paciente no debe conectar ning n dispositivo en el puerto de comunicaci n de datos a menos que su m dico o proveedor de asistencia sanitaria as se lo indique nicamente los productos ResMed han sido dise ados para conectarse al puerto de comunicaci n de datos Conectar otros dispositivos puede provocar lesiones o da os al equipo S8 Serie II El equipo S8 Serie Il debe utilizarse nicamente con las mascarillas y conectores recomendados por ResMed o por un m dico o terapeuta respiratorio Las mascarillas no deben utilizarse a menos que el equipo S8 Serie Il est encendido y funcionando correctamente Nunca se debe obstruir el o los orificios de ventilaci n asociados con la mascarilla Explicaci n El equipo S8 Serie Il est dise ado para utilizarse con mascarillas o conectores especiales que tienen orificios de ventilaci n para que el aire fluya permanentemente hacia fuera de ellas Mientras el equipo est encendido y funcionando correctamente el aire fresco que ste proporciona hace que el aire espirado salga hacia fuera de la mascarilla a trav s de los orificios de ventilaci n No obstante cuando el equipo no est funcionando no se suministrar suficiente aire fresco a trav s de la mascarilla y es posible que se vuelva a respirar aire exhal
96. tecla Y aceptar CAMBIAR Aparece cuando es hora de Oprima la tecla Y aceptar para que MASC cambiar la mascarilla desaparezca el mensaje del visor y cambie la mascarilla por una nueva LLAMAR Aparece para recordarle que Oprima la tecla g aceptar para que PROVEE se ponga en contacto con el desaparezca el mensaje del visor y DOR m dico por ejemplo para comun quese con el m dico conversar acerca de c mo est marchando el tratamiento CAMBIAR Aparece para recordarle que Oprima la tecla S aceptar para que FILTRO debe cambiar el filtro de aire desaparezca el mensaje del visor y cambie del equipo el filtro de aire REALIZAR Aparece para recordarle que Oprima la tecla aceptar para que SERVICIO envie el equipo a fin de desaparezca el mensaje del visor y realizarle un servicio de mantenimiento comun quese con el m dico Mensajes en el visor del S8 Serie Il Espafiol 9 10 Uso de la tarjeta de datos para recoger informaci n Si el m dico necesita analizar su tratamiento le pedir que use la tarjeta de datos a efectos de copiar informaci n desde el equipo S8 Serie Il y que despu s le envie la tarjeta La tarjeta de datos se suministra dentro de un desplegable de protecci n La informaci n que se copia a la tarjeta de datos permanece almacenada y disponible en el equipo S8 Serie II C mo copiar informaci n a la tarjeta de datos 1 2 5 Encienda el S8 Serie ll y espere a que aparezca la p
97. tilizar o S rie S8 Il pela primeira vez voc poder sentir um certo desconforto ao respirar contra o fluxo de ar Isso normal Voc continuar a respirar normalmente enquanto dorme A configura o de APE tamb m pode melhorar o conforto Habitue se gradualmente a essa nova sensa o O que devo fazer quando quiser me levantar da cama durante a noite Caso precise se levantar durante a noite remova a m scara e interrompa a terapia Lembre se sempre de reiniciar a terapia e colocar a m scara quando voltar para a cama O que devo fazer se sentir que o ar est escapando pela m scara O S rie S8 Il proporciona o tratamento mais eficaz quando a m scara se encontra bem ajustada e confort vel O tratamento pode ser afetado por fugas de ar Portanto importante eliminar quaisquer fugas de ar que venham a ocorrer Por exemplo experimente reposicionar a m scara e ajustar as correias Se estiver utilizando uma m scara nasal tente manter a boca fechada durante o tratamento As fugas de ar pela boca podem diminuir a efic cia do tratamento Se as fugas de ar pela boca forem um problema experimente usar uma m scara facial ou uma correia para o queixo Entre em contato com seu m dico ou o fornecedor do equipamento para mais detalhes Se estiver usando uma m scara facial e tiver problemas ao tentar encontrar um ajuste confort vel contate seu m dico ou o fornecedor do equipamento Voc poder se beneficiar de um tamanho ou estilo
98. tre datos de Smart Data Para obtener m s informacion acerca de Smart Data comuniquese con el m dico Men de opciones Para acceder a las opciones de este menu seleccione S en el menu de opciones Puede utilizar el men de opciones para modificar la configuraci n del idioma Desplacese hasta IDIOMA y seleccione Oprima o hasta ver la configuraci n que desee Men de servicio Para acceder a las opciones de este men seleccione SQ en el men de servicio Puede utilizar el men de servicio para ver informaci n acerca del sistema del equipo Mensajes en el visor del S8 Serie II Es posible que el m dico haya configurado el S8 Serie Il para que le recuerde acerca de hechos importantes como por ejemplo cambiar la mascarilla cu ndo insertar la tarjeta de datos si su equipo posee el m dulo correspondiente etc Los recordatorios aparecen en el visor y s lo se pueden ver cuando el equipo no est suministrando tratamiento Cuando el mensaje aparece en el visor la luz de fondo de ste parpadea El m dico puede configurar cualquiera de los siguientes recordatorios para que aparezcan en el visor Mensaje Descripci n Medida a tomar INSERTAR Aparece si su equipo posee Inserte la tarjeta de datos y siga las TARJ un m dulo para tarjeta de instrucciones que su m dico le haya dado datos Cuando haya hecho esto el mensaje desaparecer del visor Tambi n puede hacer desaparecer el mensaje oprimiendo la
99. uit respiratoire ou de l appareil Ces solutions peuvent causer le durcissement du mat riel et r duire sa dur e de vie Quotidien D tachez le circuit respiratoire et suspendez le dans un endroit propre et sec jusqu la prochaine utilisation Hebdomadaire 1 D tachez le circuit respiratoire et nettoyez le l eau ti de avec un d tergent doux Nettoyage et entretien Fran ais 12 2 Rincez soigneusement et suspendez le pour le faire s cher 3 Remontez le masque et le harnais avant de les r utiliser 4 Raccordez le circuit respiratoire nouveau Mensuel Nettoyez l ext rieur de la S8 Il l aide d un chiffon humide et d un savon liquide doux V rifiez que le filtre air n est ni perc ni bloqu par de la salet Remplacez le tous les six mois ou plus souvent si l appareil est utilis dans un endroit poussi reux Remplacement du filtre air ATTENTION Ne pas laver le filtre air Il n est ni lavable ni r utilisable Lecouvercle du logement du filtre air prot ge l appareil contre tout d versement accidentel de liquides Veiller ce que le filtre air et le couvercle de son logement soient toujours en place Retirez le couvercle du logement du filtre air l arri re de l appareil Couvercle du logement du filtre air 2 Retirez et jetez le filtre air usag S Ins rez un nouveau filtre air avec la face bleue dirig e vers l ext rieur 4 Remettez le
100. us retournez vous coucher Qu est ce que je dois faire si je sens des fuites d air au niveau du masque La S8 Il d livre un traitement optimal lorsque le masque est bien ajust et confortable sans tre trop serr Le traitement peut tre affect par les fuites c est pourquoi il est important de les liminer lorsqu elles se produisent Vous pouvez par exemple essayer de repositionner le masque et d ajuster les sangles Si vous utilisez un masque nasal essayez de garder la bouche ferm e pendant le traitement Les fuites d air buccales peuvent diminuer l efficacit de votre traitement Si les fuites buccales vous posent probl me vous avez la possibilit d utiliser un masque facial ou une mentonni re Contactez votre clinicien ou votre prestataire de sant pour de plus amples informations Si vous utilisez un masque facial et avez du mal ajuster votre masque confortablement contactez votre clinicien ou votre prestataire de sant Il est possible qu une autre taille ou un autre type de masque permette de r soudre votre probl me Est ce que je dois prendre des pr cautions sp ciales avant de mettre le masque Avant de mettre votre masque lavez vous le visage pour liminer tout exc s de s bum Cette pr caution permet un meilleur ajustement du masque et prolonge la dur e de vie de la bulle du masque N utilisez pas de cr me hydratante lorsque vous portez le masque J ai la bouche s che pendant le traitement Qu est ce
101. vez Si vuelve a insertar la tarjeta de datos despu s de haber actualizado la configuraci n el mensaje no volver a aparecer Retire la tarjeta de datos del S8 Serie II Cuando no la est utilizando guarde la tarjeta de datos en el desplegable de protecci n ADVERTENCIA Si el m dico le ha indicado que use la tarjeta de datos para actualizar la configuraci n de su equipo y el mensaje Configuraci n correcta no aparece comuniquese inmediatamente con l Limpieza y mantenimiento ADVERTENCIA Peligro de electrocuci n No sumerja el equipo ni el cable de alimentaci n en agua Siempre desenchufe el equipo antes de limpiarlo y aseg rese de que est seco antes de enchufarlo nuevamente PRECAUCI N No cuelgue el tubo de aire a la luz solar directa ya que puede endurecerse con el tiempo y terminar agriet ndose No utilice lej a cloro alcohol soluciones arom ticas jabones humectantes o antibacterianos o aceites aromatizados para limpiar el tubo de aire o el equipo Estas soluciones podr an endurecer el producto y reducir su vida til Limpieza diaria Desconecte el tubo de aire y cu lguelo en un lugar limpio y seco hasta el pr ximo uso Limpieza semanal 1 2 3 4 Retire el tubo de aire y l velo con agua tibia y detergente suave Enju guelo bien cu lguelo y d jelo secar Antes de usarlo otra vez vuelva a montar la mascarilla y el arn s Vuelva a conectar el tubo de aire Limpieza m
102. votre cou pendant que vous dormez 3 Pour d marrer le traitement appuyez sur la touche Camo Si votre clinicien a configur votre appareil pour qu il d marre le traitement automatiquement gr ce la fonction SmartStart votre appareil d marre lorsque vous respirez dans votre masque 4 Mettez votre masque comme indiqu dans son mode d emploi AVERTISSEMENT Le masque ne peut tre utilis que si la S8 Il est sous tension et si elle fonctionne correctement Au d but du traitement si une rampe a t r gl e la pression augmente d une pression basse confortable la pression prescrite pour le traitement sur la dur e r gl e La rampe vous aide vous habituer progressivement l augmentation de la pression et am liore ainsi votre confort Arr t du traitement Pour arr ter le traitement tout moment retirez votre masque et appuyez sur la touche cums Si votre clinicien a activ SmartStart retirez simplement votre masque pour arr ter le traitement Modification des r glages de votre S8 Il Vous pouvez modifier les r glages tels que la dur e de rampe et le niveau d EPR de la S8 Il l aide du clavier et de l cran LCD Lorsque l appareil est en mode d attente vous pouvez afficher une s rie d crans menu sur l cran LCD afin de voir et de modifier les r glages d une fonction particuli re Menu standard Votre clinicien a activ le menu sur votre S8 Il La figure repr sente le menu standard
103. w any CARD Data Card enabled instructions that your clinician has given you When you have done this the message will disappear from the LCD Pressing S Ok will also remove the message REPLACE May appear when your mask Press el Ok to remove the message MASK is due for replacement from your LCD and replace your mask with a new one CALL May appear as a reminder to Press Ok to remove the message PROVIDER contact your clinician eg to from your LCD and contact your clinician discuss how your therapy is going REPLACE May appear as a reminder to Press Ok to remove the message FILTER replace the air filter on your from your LCD and replace the air filter device SERVICE May appear as a reminder to Press Ok to remove the message DUE return your device for service from your LCD and contact your clinician Using the Data Card to Collect Data If your clinician needs to review your treatment they will ask you to use the Data Card to copy data from your S8 Series Il and to return the card to them The Data Card will be provided in a protective folder Data that is copied to a Data Card is still stored and available on the S8 Series ll device Copy Data onto the Data Card 1 Switch on the S8 Series Il and wait until you see the standby Ramp screen 2 Hold the Data Card with the arrow facing up and insert it into the Data Card slot until it stops Data copying starts automatically The C
104. you put the device on the floor make sure the area is free from dust and clear of bedding clothes or other objects that could block the air inlet Make sure the area around the device is dry and clean Connecting the Device LCD and Keypad Selecting the Mask Type To ensure your device functions as intended with your selected mask you need to select the mask type that you are using 1 2 3 4 5 With the RAMP or SETTLING screen displayed press ER In CPAP mode the standby screen displays RAMP In AutoSet mode S8 AutoSet ll only the standby screen displays SETTLING Press until MASK is displayed Press Y to change the setting Press or until you see the setting that you require sun Press to apply Using the Mask fitting Feature You can use the S8 Series Il mask fitting feature to help you fit your mask properly This feature delivers air pressure for a three minute period prior to starting treatment during which you can check and adjust your mask fit to minimize leaks Note Make sure that the mask setting on the MASK screen is the same as the mask you are using 1 2 Fit your mask as described in the mask user instructions With the RAMP or SETTLING screens displayed hold down for at least three seconds until air pressure delivery starts Setting up the S8 Series II English Your device will ramp to the mask fit pressure and will remain at this pressure for three minutes The fo
105. z pas votre S8 Il pendant le d collage ou l atterrissage Est ce que je peux utiliser ma S8 Il s il n y a pas d alimentation secteur AC Un convertisseur DC 12 a t pr vu pour la connexion de la S8 Il une alimentation de 12 ou 24 V CC Contactez ResMed pour plus de d tails Strat gie de d pannage En cas de probl me reportez vous aux suggestions suivantes Si le probl me persiste contactez votre prestataire de sant ou ResMed N essayez pas d ouvrir l appareil Probl me Cause possible Solution Aucun affichage L alimentation n est pas V rifiez que le c ble d alimentation est branch et que connect e l interrupteur de la prise de courant le cas ch ant est sur marche Le d bit d air d livr par la S8 Il est insuffisant La dur e de rampe ou le Attendez que la pression augmente ou modifiez la dur e temps d attente est utilis de rampe ou le temps d attente Le filtre air est sale Remplacez le filtre air Le circuit respiratoire est D sentortillez ou remplacez le circuit respiratoire entortill ou perc Le circuit respiratoire n est pas V rifiez le circuit respiratoire correctement raccord Le masque et le harnais sont Ajustez la position du masque et du harnais mal mis en place Un ou des bouchons Remplacez le s bouchon s manquent au niveau des ports du masque La pression requise pour le Consultez votre clinicien pour ajuster la pression traitement a peut tre ch
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalação KW1M-H Eco-POWER METER User's Manual CHRISTEN EAGLE II Manual Técnico Penta Jet Flex Híbrida - Rev4 (Passo de TK-110 TDA8787A Interface front end board camera CAMDEMO 8787A „Power Punch“ „Power Punch“ Français BEERS Technic GmbH, 6330 Cham, Switzerland LG Electronics WF-T1291TP Washer User Manual Copyright © All rights reserved.
Failed to retrieve file