Home

Renesas R8C/13 User's Manual

image

Contents

1. icon to compile assemble and link the project Programming and Debug Ensure the SessionR8C_E8 SYSTEM session in the right hand drop down list on the toolbar is selected Debug SessionAbl Eb SYSTEM Emulator mode on Click the lt Connect gt button on the debug toolbar The Emulator mode dialog will be shown Select the correct device type e g R5F21134 for RSKR8C13 Device REF211342 2 CO C i SSC Y Please note that the Emulator mode wizard shown here will only reel eee eee appear the FIRST time you connect to the target within a project On r subsequent connections the Emulator setting dialog will appear Program Flash please choose the same options to connect e Select Erase Flash and Connect F Power Target from E8 MAX 300m If the E8 is to provide power to the CPU board select P ower Target from eoo E8 and choose the 5 0V option coca Do not show this dialog box again Otherwise connect a 5V centre positive supply Click lt Next gt Ensure the Enable advanced setting checkbox is cleared Click lt Next gt then lt Finish gt D007054 11 S01 V04 34 J 36 Si 38 39 40 The first time the E8 is used a warning message box Please choose eS driver will be shown Click lt OK gt ter Uar Otherwise skip to step 37 Driver Details The Driver Details dialog will be shown Select
2. gt to continue Click lt Next gt on all screens until the Installation process commences After the installation the machine s site code will be shown this is not important at this stage click lt Next gt then lt Finish gt The Auto update dialog box will be launched Configure the Auto update settings dialog to allow the installation to be checked for available updates Connection Now connect the E8 to J6 E8 on the CPU board using the ribbon cable also connect the LCD module to 8 on the CPU board ensuring that the pin 1 designation corresponds to the marking on the CPU board Connect the E8 emulator to a spare USB port The Found New Hardware Wizard will appear Please follow the steps below to install the drivers Note that administrator privileges are required for a Windows 2000 XP machine 13 14 15 16 Verify the Recommended option is selected and click lt Next gt If using Windows XP skip to step 16 otherwise click lt Next gt Click lt Next gt to install the driver Click lt Finish gt to close the wizard Note The Windows driver signing dialog may be displayed Please accept the driver to continue D007054 11 S01 V04 3 High performance Embedded Workshop Workspace High performance Embedded Workshop integrates various tools such as compiler assembler debugger and editor into a common graphical user Interface To learn more on how to user High performance Embedded Workshop open the H
3. Everywhere you imagine E g E NI ESAS Q U IC K S ta rt Renesas Starter Kit for R8C 13 LCD module Application Board Interface Reset switch E8 header LCD modul FE ie module s 3S d aun connector rer an ini RAEE e 19ndowd wj s YELOOIPELIZS y 1 E1968 E8 emulator Application Board Interface User LEDs Analog adjust User switches D007054 11 S01 V04 1 Installation Do not connect the E8 emulator hardware until the software support has been installed 1 aS E a Yl 2 11 12 Insert the CD into your computer s CD ROM drive The CD should automatically run the installation program If the installer does not Start browse to the RSK directory from the CD root folder and double click on setup exe The installer will ask you which language Is to be used please choose the appropriate one On the first screen of the installer proper click lt Next gt The License Agreement will be shown click lt Yes gt The next screen asks you to pick the world region please select and click lt Next gt Select the software components to install For the RSKR8C13 please select High performance Embedded Workshop and all sub options M16C 60 30 Tiny 21 10 R8C Tiny Series and sub options Flash Development Toolkit and the Auto Update Utility Click lt Next gt to continue The destination folders are specified on the next screens Itis recommended to accept the default settings Click lt Next
4. Renesas E Series USB Driver Interface USE interfase sts After a short delay while the hardware is interrogated select USB crame iasan Interface The channel number will vary Click lt Close gt Configuration Configure Accept any dialogue warning that an older version of E8 firmware is necessary to work with the application Allow download of firmware to complete this may take several seconds Right click on the download module listed in the left hand pane and ia Download me I select Download _ bit The code will be downloaded to the microcontroller This may take Depen Download Fl Download Debug Data Onl several seconds iiia LL pon Unloa of In ve lc Download A New Module Click the lt Reset Go gt button The code will run and you will see the LEDs flash on the board Click the lt Stop gt button E The code will stop and the source code will be opened at the current program counter D007054 11 S01 V04 5 Next Step After you have completed this quick start procedure please review the tutorial code and sample code that came with the kit You can add projects to the current workspace by selecting Project gt Insert Project from the main menu The tutorials will helo you understand the device and development process using Renesas Development Tools The Hardware manual supplied with this Renesas Starter Kit is current at the t
5. igh performance Embedded Workshop manual installed on your computer Start Menu gt All Programs gt Renesas gt High performance Embedded Workshop gt Manual Navigator 17 18 19 20 21 22 23 24 25 26 21 28 29 30 3l 32 33 Launch High performance Embedded Workshop from the Start Menu Start Menu gt All Programs gt Renesas gt High performance Embedded Workshop gt High performance Embedded Workshop In the Welcome dialog box Verify Create New Workspace is selected Click lt OK gt In the New Project Workspace dialog box Set the CPU Family to M16C and verify the Tool chain is set to Renesas M16C Standard Select RSKR8C13 from the left hand pane Enter a name for the workspace The project name will be automatically completed with the Workspace name You can change this name to Tutorial if required Click lt OK gt On the RSKR8C13 Step 1 window Select Tutorial and click lt Next gt On the RSKR8C13 Step 2 window Click lt Finish gt On the Project Generator Information window Click lt OK gt The project that is created has two configurations The Release configuration can be used for the final release code version The Debug configuration allows modifications to the configuration for debugging Select the Debug build configuration in the left hand drop down list on the toolbar Click on the Build
6. ime of publication Please check for any updates to the device manual from the Renesas website at www renesas com renesas starter kits 6 Renesas M16C Compiler The version of the compiler provided with this Renesas Starter Kit is fully functional but time limited You have 60 days to evaluate the full product before the compiler will limit the code linker to 64k bytes Full licensed M16C compiler versions are available from your Renesas Supplier 7 Support Online technical support and information is available at www renesas com renesas starter kits Technical Contact Details America techsupport rta renesas com Europe tools support eu renesas com Japan csc renesas com Note on Autoupdate The Autoupdater is configured to automatically add itself to the Startup folder in the Windows Start Menu and use the registry defaults for access to the web After restarting the machine the Icon will appear in the System Tray next to the clock To change the settings or access Autoupdate simply right click on the icon and use the menu that appears Renesas Solutions Corporation 2006 Renesas Technology Europe Ltd 2006 Renesas Technology Corporation 2006 D007054 11 S01 V04

Download Pdf Manuals

image

Related Search

Related Contents

  Hasselblad CFV-50 3034216 User's Manual  Invacare At`m and At`m Qt Owner`s Manual  FR Le mode d`emploi.  Manual del usuario  CLM HD6  Elite 5 Sonar/GPS & Elite 5m GPS Installations  Canon EOS-1D Product Guide  LEDテープライト(側面発光)  Contents - くすりの適正使用協議会  

Copyright © All rights reserved.
Failed to retrieve file