Home
Renesas FP-144H User's Manual
Contents
1. IC socket User system Figure 1 HS2378ECH61H User System Interface Cable RENESAS Table 1 lists the HS2378ECH61H components Please make sure you have all of these components when unpacking Table 1 HS2378ECH61H Components No Component Quantity Remarks 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the FP 144H package 4 Socket cover 1 For installing an FP 144H packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 8 mm 4 For installing an FP 144H packaged MCU with four flat washers 7 CTS screws M3 x6 mm 2 For fastening the emulator station Documentation 1 User s manual for HS2378ECH61H this manual 2 RENESAS Section 2 Connection Procedures 2 1 Connecting User System Interface Cable to Emulator Station AWARNING Observe the precautions listed below Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST 1 Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and e
2. 1 dnstallinie IC Socket srren e e aeee ne odra OE a denen 5 22 2 SOMME IC Sockets isidorei n errena oraa EEEE EEE EE REESE 5 2 2 37 Inserting Cable Head cists ccsctersccdiseccetliveiscthessascsscecaceaieecatseiiuceschbeecessheencetsueeceiots 6 22 4 asteninp Cable Headissa coania oneri cas ceoseessasesecsisvascaantdcsdaccetessvens 6 22 5 Fastening Cable Body i siic ccccccsveccsavsccssdivccscisgecacee sascha ces cdst eusencis a aa 8 2 3 Recommended Dimensions for User System Mount Pad 0 ee eeeseceeeeeeneeeeceseeeeeeeenees 9 2 4 Dimensions for User System Interface Cable Head eee eeeeseeeceseceeeeecneeeecseeeeeeaeenees 10 2 5 Resulting Dimensions after Connecting User System Interface Cable eee 11 Section 3 Installing the MCU to the User System eee eeeeeneeeneeeteetees 12 Section 4 Verifying Operation ssseesesesesssesessseessressrrsseeeseeesseessressersseeesseee 14 SCHONS NOISE ninraisinoreirn niiina EAEE A AEE RAA 15 ii RENESAS Section 1 Configuration CAUTION Use an 1C149 144 045 B51 socket manufactured by YAMAICHI ELECTRONICS CO Ltd for the FP 144H package IC socket on the user system Figure shows the configuration of the HS2378ECH61H user system interface cable for the FP 144H package CTS screws M3 x 6 mm for fastening the emulator station Screws M2 x 12 mm with flat washers Screws M2 x 8 mm 2 for fastening cable head with flat washers Socket cover Cable head
3. bears no responsibility for failure or damage when used beyond the guaranteed ranges Even within the guaranteed ranges consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail safes so that the equipment incorporating Renesas product does not cause bodily injury fire or other consequential damage due to operation of the Renesas product This product is not designed to be radiation resistant No one is permitted to reproduce or duplicate in any form the whole or part of this document without written approval from Renesas Contact Renesas s sales office for any questions regarding this document or Renesas semiconductor products Preface Thank you for purchasing this user system interface cable HS2378ECH61H for the Renesas s original microcomputer H8S 2378 Series The HS2378ECH61H is a user system interface cable that connects an H8S 2678R Series E6000 emulator HS2678REPI61H hereinafter referred to as the emulator to the IC socket for a FP 144H package for the H8S 2378 Series MCU on the user system RENESAS Contents Section 1 ConficuratioN srna E adenine 1 Section 2 Connection Procedures 1x scsaicosncdsinsedaiasnieudsvenrglesasitaissabdgadvnasabienswanes 3 2 1 Connecting User System Interface Cable to Emulator Station 1 sees srrerersnrnree 3 2 2 Connecting User System Interface Cable to User System ou ee eeeeeceeeeeneeeeceseeeeeeeenees 5 2 2
4. care such as manually securing the IC socket soldered area to prevent the IC socket from being damaged by overtightening the screws or twisting the components RENESAS Screws M2 x 8 mm with flat washers Socket cover MCU Pin 1 IC socket IC149 144 045 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Figure 8 Installing MCU to User System 13 RENESAS 1 Section 4 Verifying Operation When using the E6000 emulator for the H8S 2378 Series turn on the emulator according to the procedures described in the E6000 Series Emulator User s Manual HS2000EPI61 HE Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins If an error is detected recheck the soldered IC socket and the location of pin 1 The emulator connected to this user system interface cable supports two kinds of clock sources as the MCU clock an emulator internal clock and an external clock on the user system For details refer to the Emulator Supplementary Information HS2678REPI61 HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To use the external clock on the user system Select target clock t or t2 with the CLOCK command emulator command Supply the external clock from the user s
5. H8S 2378 Series FP 144H User System Interface Cable HS2378ECH61H for E6000 Emulator User s Manual CENESAS Cautions Renesas neither warrants nor grants licenses of any rights of Renesas s or any third party s patent copyright trademark or other intellectual property rights for information contained in this document Renesas bears no responsibility for problems that may arise with third party s rights including intellectual property rights in connection with use of the information contained in this document Products and product specifications may be subject to change without notice Confirm that you have received the latest product standards or specifications before final design purchase or use Renesas makes every attempt to ensure that its products are of high quality and reliability However contact Renesas s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Renesas
6. Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Screws M2 x 12 mm with flat washers Cable head IC socket 1C149 144 045 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Figure 3 Connecting User System Interface Cable to User System RENESAS 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body User system Removing Push the unfastening jigs Figure 4 Fastening Cable Body RENESAS 2 3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad footprint for the user system with an IC socket for an FP 144H package IC149 144 045 B51 manufactured by YAMAICHI ELECTRONICS CO Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad 23 30 min et 20 00 max a ja 0 50 x 35 17 50 0 05 0 50 0 05 0 30 0 05 il lt ll HH Figure 5 Recommended Dimensions for Mount Pad RENESAS 2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 76 2 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Int
7. able Cable head is parallel g to emulator station E EN Tl Cable head is parallel to user system eee User system 6 Figure 10 User System Interface Cable Location Example The P1 jumper is used for testing Do not remove the jumper pin inserted on pin side Figure 11 P1 Jumper RENESAS
8. en it to the user system before soldering 2 2 2 Soldering IC Socket After fastening solder the IC socket for an FP 144H package to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU RENESAS 2 2 3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin 1 on the IC socket for an FP 144H system interface cable head into the IC socket on the user system as shown in figure 3 2 2 4 Fastening Cable Head CAUTION Use a Philips type screwdriver whose head matches the screw head The tightening torque must be 0 294 Nem or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary RENESAS Fasten the user system interface cable head to the IC socket for an FP 144H package on the user system with the four screws M2 x 12 mm with four flat washers provided Each screw should be tightened a little at a time alternating between screws on opposing corners
9. erface Cable Head 10 RENESAS 2 5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 N Ke mM Cable head gt e eee t IC socket Unit mm Tol 40 5 User system IC149 144 045 B51 olerance mm manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 RENESAS Section 3 Installing the MCU to the User System CAUTION Check the location of pin 1 before inserting Use a Philips type screwdriver whose head matches the screw head The tightening torque must be 0 294 Nem or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the socket cover with the provided four screws M2 x 8 mm with flat washers Take special
10. mulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection or removal while making sure not to bend or twist the cable or connectors Otherwise the connectors will be damaged 2 After making sure the direction of the cable body connector is correct firmly insert the cable body connector into the emulator station socket and fasten the emulator station with two CTS screw M3 x 6 mm figure 2 RENESAS r station Emulato Qo Bp a AZ lt Cable body connector CTS screws M3 x 6 mm User system interface cable Figure2 Connecting User System Interface Cable to Emulator Station RENESAS 2 2 Connecting User System Interface Cable to User System SM WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 144H package and fast
11. ystem to the emulator by inputting the external clock from the EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and XTAL terminals For details refer to section Clock Pulse Generator in the H8S 2378 Series Hardware Manual Figure 9 shows the oscillator circuit on the user system interface cable R1 1 MQ HCU04 To E6000 emulator R2 270 Q EXTAL XTAL 14 Figure 9 Oscillator Circuit RENESAS 4 Section 5 Notice Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU This user system interface cable is specifically designed for the HS2678REPI61H emulator Do not use this cable with any other emulator station To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 10 Place components so that the cable body and cable head are parallel to the user system Emulator station C