1. Ground Lug Plug fan power cord into rear receptacle Diagram 1 5 Connect fan ground cable to ground lug Refer to wiring diagram 6 Slide the thermodisc cover assembly into the bracket clip on the underside of the firebox Check that no wire will touch the hot surfaces Diagram 2 7 Ba Thermodisc Bracket 7 Attach the Fan control box to the ON OFF control box Diagram 3 Burner Diagram 3 Use the clip amp hook on the side of the control boxes to join them together 8 Secure the two boxes together with one Screw Secure the 2 boxes together with one screw 9 Attach the two control boxes to the bottom louver and tighten the 2 screws on the left side and 2 screws on the right side Secure right side with 2 screws 10 Secure the fan wires and power cord by attaching one of the adhesive backed wire holder clips Part 4910 199 onto the stove base Use the second clip to bundle up the wires approximately 4 fromthe control box Ensure thatthere is no interference with the wires when the louver is closed and that no wire will touch the hot metal surfaces or sharp edges 11 Plug the fan power cord into the rear end of the receptacle box to provide the maximum clearance from the
2. Gas H n To Thermocouple IN SLT Valve White To TH M a Ae 9 on x s m m mum sl Km unes ol Remote Receiver Remote Transmitter or Thermostat Optional Millivolt Optional 5 Openings for electrical connections Caution Ensure that the vvires do CAUTION Label all wires not touch any hot surfaces and are BID COMI L li 5 127mm away from sharp edges when servicing controls l VViring errors can Cause Ny improper and dangerous operation ak pm 3 3 4 2 38 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this manual eher Nut o 3 Ground 4 8 Ground Lug o 8 28 R a 6 E eutral for mobile home T so 4 Kai o Q 7 8 OL Live e O m 120V A Ground ON A OFF Pilot i Black Red Assembly H m Lockvvasher Rotary Speed Fan Thermodisc Control normally open Fa P eS YU ground wire ON DINE em m dr
3. Diagram 6 Install wall thimble in the center of the 11 279mm square and attach with wood screws Diagram 7 WOOd Screws gt gt Diagram 7 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 23 INSTALLATION 1 2 3 framing UNIT INSTALLATION WITH VERTICAL TERMINATION Maintain the 1 1 4 32mm clearances air spaces to combustibles when passing through ceilings walls roofs enclosures attic rafter or other nearby combustible surfaces Do not pack air spaces with insulation Check Venting Arrangemnt Vertical Termination section for the maximum vertical rise of the venting system and the maximum horizontal offset limitations 2 4 2g Set the gas appliance in its desired location Diagram 1 Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof CC Determine if ceiling joists roof rafters orotherframing will obstructthe venting system You may wish to relocate the appliance or to offset as shown in Diagram 2 to avoid cutting load bearing members
4. plumber s tape connected REM to wall strap wall 4 strap 45 Elbovvs 5 1 x Firestop Spacer Diagram 2 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in a flat ceiling or wall cut a 11 inch 279mm square hole Frame the hole as shown in Diagram 3 and install the firestop 11 279mm square hole firestop spacer 4 Assemble the desired lengths of pipe and elbovvs Ensure that all pipes and elbovv connections are in the fully tvvist locked position and sealed NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connec tion Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional Minimum Vent Roof Pitch Height flat to 7 12 wer Female Locking Lugs B Mil Pac I gt lt I Silicone D 3 f Male T Locking over 7 12 8 12 over 8 12 9 12 over 9 12 to 10 12 over 10 12 to 11 12 over 11 12 to 12 12 3 25 Lugs 3000 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole should be of
5. FIREPLACE PRODUCTS REGENCY www regency fire com P48 2 Gas Fireplace nstallation Manual VVARNING FOR YOUR SAFETY Ifthe information in these instructions are notfollowed exactly What to do if you smell gas a fire or explosion may result causing property damage e Do not try to light any appliance personal injury or loss of life e Do nottouch any electrical switch do not use any phone in your FOR YOUR SAFETY building e Immediately call your gas supplier from a neighbour s phone Follow Installation and service must be performed by a qualified the gas supplier s instructions installer service agency or the gas supplier e f you cannot reach your gas supplier call the fire department Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Tested by Installer Please complete the details on the back cover and leave this manual vvith the homeovvner Homeowner Please keep these instructions for future reference 918 524a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 03 05 08 To the New Owner Congratulations You are the owner of a state of the art Gas Fireplace by REGENCY The P48 2 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P48 2 has been approved by Warnock Hersey for both safety and efficiency As it also bea
6. 8 Do the same with the 8 203mm liner 9 Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out o dia flue pipe with spring spacer IMPORTANT Do not locate termination hood where excessive snow or ice buildup may occur Be sure to check vent termination area after snow falls and clear to prevent accidental blockage of venting system When using snow blowers make sure snow is not directed towards vent termination area ASTROCAP XL DIMENSIONS 12 1 4 311mm 311mm 2x4 or2 x6 AstroCap XL Termination Cap 8 dia air intake CERA C Screvvs 4 per connection Wall Thimble Screvvs 2 3 per connection pleces 10 Outer Diameter Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 25 INSTALLATION P48 NG2 SYSTEM DATA For O to 4500 feet altitude Burner Inlet Orifice Sizes 7 27 Max Input Rating 51 000 Btu h Min Input Rating 29 000 Btu h Supply Pressure min 5 0 w c Manifold Pressure High 3 8 0 2 w c Log Set Ceramic fibre 8 per set Vent System Simpson Dura Vent Direct Vent System Regency Flex Kit P48 LP2 SYSTEM DATA Conversion Kit 372 969 For O to 4500 feet altitude Burner Inlet Orifice Sizes 47 Max Input Rating 48 000 Btu h Min Input Rating 26 000 Btu h Supply Pressure min 12 0 w c Manifold
7. Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from Regency may be used for Flex installations 3 If you are installing the P48 2 into a Regency Mantel Kit use the minimum horizontal vent height centre line of 43 Remember to include the mantel base in your calculations and to maintain the 2 1 2 clearance to the underside of the mantel top Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 13 INSTALLATION SIMPSON DURA VENT VENTING Horizontal or Vertical Terminations The Simpson Dura Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations Many items are offered in decorative black as vvell as galvanized finish VVe recommend using the galvanized finish for installation vvith the P48 2 The minimum components required for a basic horizontal termination are Horizontal Termination Cap 45 Elbow Flue Adaptor Wall Thimble Length of pipe to suit wall thickness see chart lI c Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must b
8. Spark Generator Battery Holder Spark Generator Switch C W Wire Battery Size AA Energizer En91 Clip Wire Holder Wire Fan To Power Cord Ground 30 in Instruction Sheet Velcro Hook Black Velcro Hook Black Installation of LPG Conversion Kit 1 2 3 Remove the louvers and trim kit Re move the front door Remove the logs embers Remove the grate by lifting straight up 4 Remove the burner assembly by remov ing the 1 Phillips head screw and then slide the burner assembly away from the orifice and lift out Diagram 1 Remove the left screw and then slide the burner assembly away from the orifice and 9 6 lift out Pull off the pilot cap to expose the pilot orifice Unscrevv the pilot orifice vvith the allen key and replace vvith the LP pilot orifice in the kit and replace pilot cap Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 7 Remove burner orifice vvith a 1 2 wrench and discard Use another wrench to hold on to the elbow behind the orifice 8 9 10 Burner Orifice Reinstall new burner orifice LP stamped 47 and tighten Turn control knob to the OFF position Remove the black protection cap by hand from the high low knob Fig 1 27 INSTALLATION 11 Insert a 5 32 or 4mm Allen wrench into 15 Verify that if the conversion is from NG tc Installation of the DC Sparker the hexagonal key way of the screw LPG
9. 1245G 1245BG S8DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A Selkirk Metal Fab Direct Temp Sure Seal 5D6 5DT 6 oDT 6B oDT 9 oDT 9B 5DT 12 5DT 12B 5DT 18 5DT 18B 5DT 24 5DT 24B 5DT 36 5DT 36B 5DT 48 5DT 48B N A N A N A N A 5 5 5DT EL45 N A 5DT EL45B N A N A 5045 SD45LB 5DT EL905 N A SDT EL90SB N A N A SDIOL N A 509018 N A 5D90A N A SDDA SDT CS 5DT CSS 5DT VVS B oDT OS oDT WT N A SDT FS oDT TP 15 INSTALLATION Components from different Manufacturers may not be mixed Not All Rigid Pipe components are available directly from FPI Simpson 5 Simpson Selkirk Metal Fab Description Direct Vent Pro En Direct Temp Sure Seal Discontinued Round Support Radiation Sheild N A N A N A N A Flat Flashing N A N A N A N A Attic Insulation Shield 12 58DVA IS N A from FPI 58DVA IS N A from ER Basic Horizontal Termination Kit A N A SDT HKA Horizontal Termination Kit B 58DVA KHA 5 Vertical Termination Kit 58DVA VCH 5DT VKC High Wind Vertical Cap N A N A High Wind Horizontal Cap DISC N A Horizontal Square Termination Cap N A 5DT HHC Vertical Termination Cap N A SDT HVC Storm Collar 58DVA SC 5DT SC Adjustable Flashing 0 12 6 12 58DVA F6 1243 5DT AF6 5DF Adjustable Flashing 6 12 12 12 58DVA F12 1243S 5DT AF 12 5DF 12 Vinyl Siding Standoff 58DVA VSS 1250
10. a Loosen the two screws from the bottom of the baffle plate Install the bottom clips onto the baffle plate refer to Diagram 1 Diagram 5 6 Slide the top panel and bracket assembly carefully onto the baffle plate ensuring the panel is centered Make sure the tabs of the top bracket fit into the baffle openings refer to Diagrams 6 amp 7 The back of the top brick panel sits on top of the bottom clips Tabs Diagram 1 3 Insert the back brick panel first by carefully slipping it between the Diagram 6 back wall of the firebox and the rear log bracket refer to Diagram 2 Diagram 2 A a 4 Bet i x Ee z KS d ZE Ze Diagram 7 4 Put the side panels in next Tilt them in tovvards the middle of the firebox and put the bottom front corner in first Be very careful not NOTE If the bottom brick panel must be removed Remove the to scratch them on the firebox hardware Place them flat up against grate then remove the Burner Tray See Removing the wall they should fit snugly against the top of the firebox refer to Valve section Diagrams 3 amp 4 IMPORTANT Dangerous operating conditions may occur if the panels are broken IMPORTANT gt YOUR BRICK PANELS ARE MANUFACTURED FROM A SPECIAL HEAT REFLECTIVE CERAMIC MATERIAL DO NOT FORCE INTO POSITION Diagrams 3 amp 4 30 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Read the instructio
11. 43 910 813 Power Cord 120 Volts 105 910 165 120 Volts 46 910 330 Fan Speed Control Switch 106 946 000 Flexible Air Release Duct 47 904 586 Knob Speed Control 48 910 199 Wire Holder Clip 372 969 Conversion Kit NG to LP 49 910 142 Thermodisc Fan Auto ON OFF 910 845 Wire Harness Plug In Fan 918 524 Manual 50 770 994 Optional Rigid Pipe Adaptor Not available as a replacement part 46 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace PARTS LIST 2 DOORS 8 LOUVERS PLEASE REFER SEPARATE SECTION A HEAT RELEASE DUCT KIT Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 47 PARTS LIST 52 56 57 66 67 68 69 75 79 82 90 91 93 94 95 96 97 98 100 101 Not available as a replacement part 48 Part 370 574 P 370 576 P 910 190 910 478 910 038 910 039 W840470 904 662 904 434 936 170 370 535 370 019 910 421 910 422 370 930 BURNER amp LOG ASSEMBLY Description Valve Assembly Natural Gas Valve Assembly Propane Gasket Valve Access Plate Piezo Ignitor amp Nut Valve S I T Natural Gas Propane Pilot Assy S I T 3 Flame NG 98 Pilot Assy S I T 3 Flame LP Pilot Holder Pilot Assembly Gasket 27 Orifice N G 97 47 Orifice Propane Orifice Gasket Valve Access Plate Burner Assembly 95 Burner Grate Assembly
12. Clearances section Vertical Height Feet Horizontal Feet Maximum 40 ft Minimum 10 ft Gin 3 2m v v 22 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION Install the vent system according to the manufacturer s instructions included with the components 1 2 3 4 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit Rough in the gas preferably on the right side of the unit and the electrical junction block is on the left side on the left Direct Vent pipe and fittings are designed with special tvvist lock connections to connectthe venting system to the appliance flue outlet A twist lock appliance adaptor is an available option that must be used in conjunction with the Simpson Dura Vent Direct Vent GS system Install the adaptor after the unit is set in its desired location otherwise the unit will not fit through the 36 5 8 930mm high frame opening Put a bead of silicone inside the outer section of the adapter and a bead of Stove Mate on the inner collar Slip the adapter over the existing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier Level the fireplac
13. Installation Checklist 6 Manufactured Mobile Home Additional Requirements 7 Locating Your Gas Fireplace sss 7 Unit SDecifiCallOFIS EE 7 Heatwave Optional Duct System Kit 7 Optional Heat Release Kit 7 FS AU EE 7 ET ae 8 9 Mantel Leg Clearances ccccccceececseeeceeeesseeeseseeeees 9 Framing amp Finishing 10 Unit Assembly Prior To Installation 11 Top Standoff Assembly 11 Top Facing Support and Side Nailing Strips 11 Venting Introduchon 11 Exterior Vent Termination Requirements 12 Venting Arrangements 13 Horizontal Termination 13 Simpson Dura vent Venting 14 Simpson Dura vent Venting Components List 14 5 x 8 Rigid Pipe Cross Reference Chart 15 Vertical 21 Unit Installation with Horizontal Termination 23 Unit Installation with Vertical Termination 24 System Data E 26 HOM IO VEUNO MM yz ET 26 Gas Line Installation 26 Se e In E
14. N UL Z 78 1414 Kyuedoud oiqnd uo pejeoo poeAed e JO 15 peAed AOQE 992U8JE9 2 W ug LLS 4140 3e ur Aqddns sie jeolueyoow e o 1 UU209 Z1 eoueidde saujo Aue O 3 lul Jie uonsnquuJoo y Jo Bulpying o lul Ajddns sie jeoiueuoeuu uou o Y u1006 9 UIW JUBA BOUBIeS D f J0jejn694 eu Jo y WOU jJeyuozuou u206 utum A quuesse e pej e1su 9q JON H peyiuuJed jou 51 euruJe 9JeuM eaJy jepno Addne sy uoneululJ9 JU9A M jqeu do V S9 ON 19uJoo episur O BOUBIeS D H WOEE E JeuJjoo pisino o J AUIA UO 9 2 089 62 UIW 30s pejejueAun o F Buipis AUIA Uo 9 z 0 089 62 Ulu W909 7Z JO eouejsIp Je3uozuou e UlUMA 6 1 eu e oqe D TEOO JOS pajejnuaA O eoue4e9jo 6 upDOEL SL utu MOPUIM pesojo pueueuued o 06 21 peuedo eq Aew zey JOOP JO MOPUIM O g uo SL uiu AuooJeq Jo ep uoJod epueJeA AOQE e92ueJeog Y p soro pexi4 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 12 INSTALLATION VENTING ARRANGEMENTS HORI
15. at least 1 3 8 35mm Fasten with the 3 screws drilling pilot holes will make this easier Apply Mill Pac or high temperature silicone to the 8 203mm flex pipe and slip it over the 8 outer collar of the vent terminal at least 1 3 8 35mm and fasten with the 3 screws NOTE Horizontal sections must be sup ported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner 4 Separatethe2halves ofthe wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls The liners must slip over the collars a minimum of 1 3 8 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre 5 127mm liner and outer 8 203mm liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90 7 Apply Mill Pac over the fireplace inner collar and slip the 5 127mm liner down over it and attach with 3 supplied screws
16. heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 4 Make a periodic check of burner for proper position and condition Visually check the flame ofthe burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and atleast annually by aqualified field service person to ensure that the flow of combustion and ventilation air is not obstructed Note Never operate the appliance without the glass properly secured in place 6 Donotusethis appliance if any parthas been under water Immediately call a qualified service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water 7 In the event this appliance has been serviced check that the vent air system has been properly resealed amp reinstalled in accordance with the manufacturer s instructions 8 Verify operation after servicing GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semiannually Recommended areas to inspect as follows 1 Check the Venting System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Vent Remove any bird
17. nests or other foreign material 3 Check for evidences of excessive condensation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous condensation can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Open the Bottom Louvers or Grills Remove the Top Louver or Grill 2 Open and remove door 3 Remove log set and embers 4 Remove grate and burner 5 Disconnect thermocouple by loosening nut from the valve with a 9mm wrench Disconnect thermopile by loosening 2 screws marked TP on the v
18. the screw must be re assembled Fig 2 rotate it counter clockwise until with the red o ring visible Fig 5 24 Locate the Piezo Ignitor situated at the it is free and extract it side of the valve LPG Configuration Red o ring visible 25 RemovethePiezolgnitorby unscrewing the 46 Re assemble the black protection cap nut at the back of the mounting bracket Fig 6 Ignitor Wire 12 Check that the screw is clean and if necessary remove dirt 13 Flip the screw Fig 3 Piezo Ignitor 26 Disconnectthe ignitor wire from the Piezo Ignitor and connect it to the DC Sparker DC Sparker WARNING Ignitor 14 Using the Allen wrench as shown in Also check that the pilot Wire Fig 4 rotate the screw clockwise until and main burner injectors are snug do not overtighten appropriate for the gas type 27 Connect the DC spark generator vvires 17 Reverse steps 4 to 1 to the SIT Valve with the screw which is provided in the kit 18 Attach the label This unit has been converted to LPG near or on top of the serial decal 19 Replace yellow Natural Gas label with red Propane label 20 Check for gas leaks 21 Check inlet and outlet pressures WARNING 22 Check operation of flame control Do not overtighten the screw 23 Check for proper flame appearance and Recommended to glow on logs grip the wrench by the short side 28 Regency P48 2 Zero Clearance Direct Vent G
19. to the gas valve See diagram To thermopile OPTIONAL WALL SWITCH Can be used with Option 1 or 3 but not both 1 Run the supplied 15 of wire through the back gas inlet opening Be careful not to damage wire Note We recommend a maximum of 15 of wire but if you wish to go with a longer run use the Thermostat Wire Table 2 Connectthe wire to the supplied wall switch and install into the receptacle box CAUTION Do not connect millivolt wall switch wire to a 120V wire 38m 2 To wall switch 4459 remote control 4 ei u or thermostat Emi 40 E CAUTION Do not connect millivolt remote control wires to a 120V wire 3 Install 3AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to remote mode The remote control is now ready for operation OPTIONAL WALL THERMOSTAT Can be used with Option 1 or 2 but not both A wall thermostat may be installed if desired connect the wires as per the wiring diagram in Wiring Diagram section Use the table below to determine the maximum wire length Note Preferable ifthe thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA UL
20. 00 NG Btu h 48 000 LP Btu h after burning appliance for 15 minutes 2 Ifrequired adjusting the primary airto ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1 Ensure that structural members are not cut or weakened during installation 2 Ensure proper grounding using the 8 ground lug provided See Wiring Diagram section U Top of Facing Top of Facing 1 2 3 4 NIT SPECIFICATIONS Unit Width 48 1219mm 41 1041mm 39 990mm Top of Louvers Unit Width 48 1219mm 41 1041mm 39 990mm Top of Louvers LOCATING YOUR GAS FIREPLACE When selecting a location for your fireplace ensure that the clearances outlined on this page are met Provide adequate clearances for servicing The appliance must be installed on a flat solid continuous surface e g wood metal concrete This may be the floor or raised up on a platform to enhance its visual impact If the appliance is going to be installed on carpeting combustible linoleum tile or other combustible material other than wood flooring the appliance must be installed on a metal or wood panel e
21. 1 around the thermocouple and 1 flowing across the burner it does not have to be touching the burner Note Ifyou have anincorrect flame pattern contact your Regency dealer for further instructions Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple Burner oo 00 G E E EE EE ELE 0 06 Thermopile Thermocouple Pilot Ignitor GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping from valve at pressures over 1 2 psig The manifold pressure is controlled by a regulator built into the gas control and should be checked at the pressure test point Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the lim
22. 1290G 90 Elbow Swivel Galv 1243 Flashing 0 12 6 12 1290BG 90 Elbow Swivel Black 1243S Flashing 7 12 12 12 1253 Storm Collar 1291 High Wind Term Cap Vertical Only 1250 Vinyl Siding Standoff 1285 Horiz Sq HighWind Trm Cap Only 1288 Wall Strap 1282 Snorkel 14 Rise Term Cap 1247 Wall Thimble Parts not supplied by Dura Vent 110 994 Rigid Pipe Adaptor 14 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION 5 X 8 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not All Rigid Pipe components are available directly from FPI oz Simpson 6 Pipe Length Galvanized 6 Pipe Length Black 9 Pipe Length Galvanized 9 Pipe Length Black 12 Pipe Length Galvanized 12 Pipe Length Black 18 Pipe Length Galvanized 18 Pipe Length Black 24 Pipe Length Galvanized 24 Pipe Length Black 36 Pipe Length Galvanized 36 Pipe Length Black 48 Pipe Length Galvanized 48 Pipe Length Black 60 Pipe Length Galvanized 60 Pipe Length Black Adjustable Length 3 10 Galvanized Adjustable Length 3 10 Black Adjustable Length 11 14 Galvanized Adjustable Length 11 14 Black Adjustable Length 17 24 Galvanized Adjustable Length 177 24 Black Extension Pipe 8 1 2 Galvanized Extension Pipe 8 1 2 Black Extension Pipe 16 Galvanized Extension Pipe 16 Black 45 Elbow Galvanized 45 Elbow Black 45 Elb
23. 3 by adding the following additional requirements a For all side wall horizontally vented gas fueled equipment installed in every dwelling building or structure used in whole or in part for residential purposes including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back up is installed on the floor level where the gas equipment is to be installed In addition the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be instal
24. 31132 H3A3TIN3 SVd AN 148V1 SIHL SAOWSY LON OG 1 30v dauid SVD 031 p 3sr1 l l 1 1 l l l l 9 g l l 1 1 1 1 AL33VS 40 AdOD label is located on the front inside base of the unit visible when the bottom louver is open there is a difference the label on the unit is the correct one gasfitter licensed in the Commonwealth of Massachusetts For the State of Massachusetts flexible connectors shall not exceed 36 inches in length ances individual manual shut off must be a This is a copy ofthe label that accompanies each P48 NG2 and P48 LP2 Zero Clearance Direct Vent Gas Fireplace We have printed a copy of the contents here for your review The safety NOTE Regency units are constantly being improved Check the label on the unit and if For the State of Massachusetts installation and repair must be done by a plumber or For the State of Massachusetts the appli t handle type valve The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up inthe same room where the gas appliance is installed Regency P48 2 Zero Clearance Direct Vent Gas Fireplace REQUIREMENTS MA Code CO Detector for the State of Massachusetts only 5 08 Modifications to NFPA 54 Chapter 10 2 Revise 10 8
25. 5 5 SDVS Vinyl Siding Shield Plate 5DT VSP N A Snorkel Termination 14 58DVA SNK14 1292 5DT ST14 5DST14 Snorkel Termination 36 N A 1281 oDT ST36 oDST36 Restrictor Disk 58DVA RD N A N A N A Colinear Flex Liner Adapter 3 2 N A N A N A N A FPI 946 604 P Simpson Direct Vent Vent Guard Optional 946 623 P AstroCap XL Horizontal Cap 770 994 Rigid Pipe Adapter Must use vvith all Rigid Piping 946 506 P Vent Guard Optional T esses NOTE VVhen using Metal Fab Sure Seal Rigid Piping please note that either the Adaptor 5DDA or 90 Starter Elbovv 5D90A must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 L676 amp L900 Direct Vent Fireplace IMPORTANT NOTE e A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower e The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications Only the AstroCap XL and Snorkels are certified for horizontal terminations Offset Pipe Selection Use this table to determine offset pipe lengths For specific instructions or details on particular 5 x 8 Venting venting components please visit the following Pipe Length MEZUN 0 0mm 5 11 16 144mm 15 5 16 389mm Selkirk Direct Temp vvvvvv selkirkcorp com 6 152mm 8 13 16 224mm 18 7 16 468mm 9 229mm 10 15 16 278mm 20 9 16 522mm Metal Fab Sure S
26. 6 Remove the burner by removing the screvv on the left side and then slide the burner to the left and lift out Left Side Deflector 8 Remove the base brick panels 9 Disconnect the inlet gas line 10 Remove the 10 Phillipshead screvvs securing the valve tray assembly in place and then lift the entire assembly out Remove the screw on the left side of the burner Slide the burner to the left and lift out Valve Tray Assembly Lift entire valve tray assembly out 11 Disconnect the 2 TP wires and the 2 TH wires from the valve 12 Undo the pilot tube from the valve with a 7 16 wrench 13 Undo the quick drop out thermocouple nut on the valve with a 9mm metric wrench 14 Remove the Piezo igniter wire and push button assembly Thermopile Wire Thermocouple Wire Pilot Nut 15 Undo the gas out flare nut with a 13 16 wrench 16 Undo the gas out flare fitting with an 11 16 wrench 17 Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve Hint If you are using black pipe ensure that there is a union by the valve otherwise removal will be almost impossible Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 45 PARTS LIST MAIN ASSEMBLY Part Description Part Description 1 948 259 Door Handle 51 902 331 Brick Panel Base Center 3 948 046 Chain 52 902 332 Brick Panel Base Left 4 948 115 Spring 53 902 333 Br
27. Browne Burner FF E 0 ooo oo WEEN Whiter Gas Thermostat x tan l n To Thermocouple IN S T Valve i White To TH e GA e e en en ent end e Jeng e x es 9 E ere reine Remote Recelver or Thermostat Millivolt Optional Remote Transmitter Optional Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 39 INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower The fan can be hard wired if desired The receptacle box should be installed on the left handside ofthe unitby a qualified electrician The neutral wider slot of the polarized receptacle should be at the top Unit must be grounded at all times Do not cut the ground terminal off under any circumstances 1 Shut the power off 2 Remove the standard flush door and the optional bay door if installed Open the bottom louver door 3 Remove the 2 screws holding the Burner ON OFF switch and bracket to the bottom louver and lift the assembly out 4 Turn the fan base on its side with the base facing towards you and then slide the fan in towards the rear of the unit Turn the fan upright and slip it over the two mounting studs Take care notto damage the insulation on the fan base Ensure that the fan blades do not rub against the valve tubing Diagram 1 E s 152 a 0 g Pe s 1 Push Fan down on mounting pins Electrical Receptacle
28. C or UL approved may be used CAUTION Do not connect millivolt wall thermostat wires to a 120V wire Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System 14 GA Max Length 16 GA 18 GA 20 Ft 20 GA 12 Ft 22 GA 9 Ft Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 37 INSTALLATION No electrical power supply is required for the gas control to operate 120 Volt AC power is needed for the fan switch and blower The fan can be hard wired if desired A terminal block is provided on the left hand side of the unit Athree wire power cord can also be used and plugged into a suitable receptacle WIRING DIAGRAMS Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased with the unit it is still a good idea to hardwire the terminal block in case the fan is installed at a later date However DO NOT leave this connection live until the fan is installed For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes D Nut o 3 Ground St h Q di 8 Ground Lug o 5 Neutral for mobile home 2E 4 o S of Live Ground nE 120V AC round PORZ ON OFF Pilot L Black Red Assembly i g E Rotary Speed Fan Thermodisc Control normally open
29. Fully Open Propane CAUTION Carbon will be produced if air shutter is closed too much Note Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty Adjustment Wire Pull down to open or push up to close aeration cap Closed Tall yellow Open Short Blue Note Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 41 OPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance This is perfectly normal due to the fact that there are various gauges and types of steel used vvithin your appliance Listed belovv are some examples Allare normal operating sounds and should notbe considered as defects in your appliance Blovver Regency gas appliances use high tech blovvers to push heated air farther into the room t is not unusual for the fan to make a whirring sound when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the firebox and body Therefore the varyingthicknesses of steel will expand and contract at slightly different rates which can cau
30. H TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must be electrically grounded in accordance with local codes orin the absence oflocal codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and vent should be enclosed 4 This appliance must be connected to the specified vent and termination cap to the outside ofthe building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 5 Inspect the venting system annually for blockage and any signs of deterioration 6 Venti
31. ION VENTING ARRANGEMENTS VERTICAL TERMINATIONS SIMPSON DURA VENT DIRECT VENT GS SYSTEM Propane amp Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using one 90 elbow and one 45 elbow with Simpson Dura Vent Direct Vent GS vent systems for Propane and Natural Gas Horizontal Feet 0 2 4 6 8 10 12 Vertical Height Feet Maximum 27 8 2m Max 10 3m centerline to centerline Minimum 8 6 2 6m Min 12 305mm Vent must be supported at offsets Firestops are required at each floor level and vvhenever passing through a vvall Maintain clearances to combustibles Note Must use optional rigid pipe adapter when using Simpson Dura Vent pipe Part 510 994 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 21 INSTALLATION The P48 2 is approved for a maximum 40 ft straight vertical with Simpson Dura Vent Direct Vent GS vent systems for Propane and Natural Gas as per diagram The shaded area in the diagram shovvs all allovvable combinations of straight vertical and offset to vertical terminations with Simpson Dura Vent Direct Vent GS vent systems for Propane and Natural Gas Maximum two 45 elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed inthe
32. Pilot ON OFF Extension Knob with Bay Front HI LOW Extension Knob with Bay Front P48 2 Log Set Center Cross Log Right Side Cross Log Front Left Side Log Front Right Side Log Left Side End Log Rear Log Middle Right Side Log Right Side End Log 82 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace PARTS LIST FLUSH DOOR amp LOUVERS Part Description Part Z Description 370 925 Flush Louvers Set Steel Black 150 Flush Glass Trim 370 924 Flush Louvers Set Black 904 196 Magnet 370 926 Flush Louvers Set Gold Black 133 Flush Louver Assembiy Top 370 933 Double Screen Door Complete 134 Flush Louver Assembiy Bottom 171 Door Frame Assembiy Left 172 Door Frame Assembiy Right 370 518 P Flush Door Assembly Complete 174 511 085 Handle 135 940 335 P Glass Flush 178 948 257 Lift Hinge on Door 138 Flush Door Frame 180 512 546 Door Latch Assembly 139 936 155 Glass Gasket Tadpole 188 948 216 Regency Logo Plate 140 948 042 Spring Hinge Not available as a replacement part 370 944 Finishing Trim Black 370 946 Finishing Trim Steel 141 Trim Side Left 142 Trim Side Right 143 Trim Top Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 49 PARTS LIST BAY FRONT amp LOUVERS Part Description 106 940 337 P Side Glass 107 936 243 Glass Gasket 108 940 336 P Center Glass 111 Brick Panel Left Side Bay 112 Brick Panel Right Side B
33. Pressure High 11 0 2 w c Log Set Ceramic fibre 8 per set Vent System Simpson Dura Vent Direct Vent System Regency Flex Kit HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CANT 2 17 M91 GAS LINE INSTALLATION The gas line can be brought through either the right the left side or the bottom of the appliance The gas valve is situated on the bottom of the unit The gas line connection may be made of rigid pipe copper pipe or an approved flex connector If you are using rigid pipe ensure that the valve can be removed for servicing Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI 2223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks witha soap and water solution or gas leak detector Do not use open flame for leak testing PILOT ADJUSTMENT Burner o o ooo OO OO OOO0O0O000400000020 Thermopile Thermocouple Pilot Ignitor Periodically check the pilot flames Correct flame pattern has three strong blue flames 1 flowing around the thermopile
34. ZONTAL TERMINATION Regency Direct Vent System Flex These venting systems in combination with the P48 2 Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section AstroCap XL Regency Direct Vent Flex System Partt 946 623 P Termination Kit Part 946 618 includes all E the parts needed to install the P48 2 with a Vinyl Siding BC maximum run of 4 feet Standoff Sy LD 1 8 dia flexible liner 6 ft length VVall Thimble s 2 5 dia flexible liner 6 ft length required in 3 spring spacers 4 Canada only 4 thimble 2 5 AstroCap XL termination cap 1 6 screvvs 12 5 dia 7 tube of Mill Pac 1 Flue pipe 8 plated screvvs 8 9 screws 8 x 1 1 2 Drill Point 8 dia Stainless Steel 4 Flue pipe 10 vinyl siding standoff Iflongerruns are needed the Regency Direct Vent system Flex Part 946 616 includes all the parts needed to install the P48 2 with a maximum 10 run 1 8 dia flexible liner 10 ft length 2 5 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap XL termination cap 1 6 screvvs 12 7 tube of Mill Pac 1 8 plated screvvs 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 10 vinyl siding standoff
35. alve 6 Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple or thermopile with a 7 16 wrench NOTE the pilot line is very fragile use caution when pulling it up 7 Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit 8 Reinstall the new ones in reverse order GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket Part 936 155 GOLD PLATED LOUVERS amp TRIM The 24 carat gold plated finish on the louvers and trim requires little maintenance and need only be cleaned with a damp cloth DO NOT use abrasive materials or chemical cleaners as they may harm the finish and void the warranty Clean any fingerprints off before turning the unit on Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 43 MAINTENANCE DOOR GLASS Your Regency fireplace is supplied with high temperature 5mm Ceramic glass If your glass requires cleaning we recommend using an approved glass cleaner available atall authorized dealers Do not use abrasive materials CAUTION amp WARNINGS Do not clean when the glass is hot The use of substitute glass will void all product warranties Care must be taken to avoid breakage of the glass Do not strike or abuse the glass Do not operate this fireplace without the glass front or with a cracked or broken glass front Wear gloves when removing damaged or
36. as Fireplace INSTALLATION 28 Locate the ground lug atthe receptical box 32 Plug the DC spark generator wires to the 35 Mount the heat shield to the DC Sparker left of the unit DC Sparker Secure into place with the velcro which is provided in the kit ae 29 Connect one end of the supplied green 36 Find a location which is not too hot and ground wire to the lug with the nut and l is easy to reach for changing the battery washer from the kit 33 Connectthe ground wire tothe DC Sparker Note It should be kept away from the mounting bracket chain Ground wire from kit 30 Install the 1 2 bushing to the heat shield gemeng 37 Tie up the loose vvire vvith the vvire clip 34 Install the supplied battery into the Sparker Box by opening the battery compartment NOTE The battery in the DC Sparker Box will need to be replaced annually Battery Compartment 31 Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield Heat Shield Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 29 INSTALLATION BRICK PANELS INSTALLATION 1 Unhook the 2 spring loaded hooks from the bottom of the flush door 5 Place the top bracket onto the front edge of the top panel refer to and lift the Flush Front off the unit Diagram 5 2 Unwrap the brick pattern panels from the protective wrapping Note The logs must not be in the unit
37. ay 113 370 086 Bay Door Trim Each Black 115 Bay Louver Assembly Top 116 Bay Louver Assembly Bottom 117 904 196 Magnet 1 round 119 370 093 Bay Door Baffle 120 400 189 Flush Glass Retainer Bracket 122 948 216 Regency Logo Plate Not available as a replacement part 120 106 120 107 120 ad fal a 50 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace VVARRANTY REGENCY Regency Fireplace Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility FPI Fireplace Products International Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Excalibur Product This warranty is not transferable The Warranty Limited Lifetime The combustion chamber heat exchanger burner tubes pans logs brick panels and gold plating against defective manufacture only are covered under the Limited Lifetime Warranty for five 5 years for parts and subsidized labour and parts only thereafter Glass is covered for lifetime against thermal breakage only parts and subsidized labour for five 5 years and parts only thereafter from date of purchase External casting surrounds and grills are covered against cracks and warps resulting from manufacturer defects parts and subsidized labour for three 3 years from the date of purchase and parts onl
38. bolt Horizontal 7 8 fold strap sheet metal 9 lt to Vinyl Standoff ill O O t HOT LH LO o lt 4 screws Vinyl siding standoff Wall Thimble Diagram 5 4 The four vvood screvvs provided should be replaced vvith appropriate fasteners for stucco brick concrete or other types of sidings Before connecting the horizontal run of vent pipe to the vent termination slide the Wall Thimble Part 1247 over the vent pipe Slide the appliance and vent assembly tovvards the vvall carefully inserting the vent pipe into the vent cap assembly It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1 1 4 inches 32mm Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect the strips to the pipe section See Diagram 6 1 1 4 32mm here screw INE wall thimble cover strap
39. bor coverage is included with these parts Conditions Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers t is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this information the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend t
40. broken glass Replacement of the glass panel s should be done by a licensed or qualified service per son GLASS REPLACEMENT Inthe eventthat you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped already installed into the door frame Reinstall as per Glass Door Installation in Standard Flush Door section CAUTION Wear gloves when removing damaged or broken glass WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass panels should be done by a licensed or qualified service person BAY GLASS REPLACEMENT 1 Remove the door from the unit and place on a soft surface to prevent scratching 2 Remove the nuts holding the glass clips in place and remove 3 Replace the glass The glass must have gasketing around it 4 Reversethe previous steps replace the glass clips and fasten with the nuts but do not over tighten as this can break the glass 5 Replace door on the stove and check the seal INSTALLING VALVE 1 Attach the valve to the valve bracket with the 4 m5x8 metric screws provided 2 Reconnect the gas out flare fitting with an 11 16 wrench 3 Reconnect the gas out flare nut with a 13 16 wrench 4 Install piezo ignitor push button assembly and reconnect wire 5 Reconnectthe quick drop outthermocoupl
41. ce to combustible materials are not adhered to It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions The HeatWave Duct Kit and the Heat Release Kit have different clearance and framin requirements check the HeatWave and at Release Kit Heat Release manual for Heat Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION MANTELS Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from louver are shovvn in the diagram belovv Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantel Clearances 12 10 8 6 4 2 0 lt MEN 2 This drawing is to scale at 1 6 one inch 6 14 12 Mantel l inches ee Drywall Mantel can be installed anywhere in shaded area 12 using the above scale for units with the Flush o E A Front and with the optional Bay Front m 5 1 2 Mantel Top A Nailing Top Note Ensure the paint that is used al 3 Mantel Strip Standoff on the mantel and the facing is 15 2 n heat resistant or the paint may discolour 6 10 4 8 0 y A v 41 Top to floor Louvers Side View MANTEL LEG CLEARANCES Combus
42. d FIRST FIRE DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured itis recommended that you burn your fireplace for at least four 4 hours the first time before you use it with the fan on When first operated theunitwill release an odour caused by the curing of the paint the burning off of any oils remaining from manufacturing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours Note When the glass is cold and the appliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down The wire is accessed through the bottom louver opening Open the air shutter for a blue flame or close for a more yellow flame The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude Minimum Air Shutter Opening 3 16 Natural Gas
43. ducts made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI may nullify your warranty on this product Any alteration to the unit which causes sooting or carboning that results in damage to the interior exterior facia is not the responsibility of FPI Subsidy according to job scale as predetermined by FPI Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 51 FPI fireplaces are designed vvith reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door FPI Fireplace Products International Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product See the inside back cover for details Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed Serial No ge 1C and Panorama are trad emarks of FPI Fireplace Products International Ltd 2008 FPI Fireplace Products International Ltd All rights reserved
44. e nut with a 9mm wrench 6 Reconnect the pilot tube nut with a 7 16 wrench 7 Scrapeofftheold gasketfromthe floor ofthe firebox and from the valve tray assembly 8 Install a new gasket and reinstall the valve tray assembly Note Failure to install a new gasket may severely affect the appliance performance 9 Reinstall the 10 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve 11 Reinstall the two bottom deflectors and brick panels 12 Install burner and grate assembly 13 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak testing 14 Fire up the unit temporarily 15 Check the manifold pressure 16 Reinstall the logs and brick panels as needed 17 Close the door and replace the louvers 18 Fire up the unit again and check for proper flame appearance and glow on logs 44 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace MAINTENANCE 7 Remove the right and left side deflectors by removing the 2 screws on each deflector REMOVING VALVE 1 Shut off the gas supply 2 Remove the louvers and bay door if it has been installed 3 Open the flush door and remove the door M uu gt E in Cl 4 4 Remove the logs and side brick panels if installed 5 Remove the grate by lifting up and out Right Side Deflector Grate
45. e and fasten itto the framing using nails or screws through the nailing strips Assemble the desired combination of pipe and elbows to the appliance adaptor and twist lock for a solid connection Note a Twist lock procedure Fourindentations located on the female ends of pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends Diagram 1 Push the pipe sections completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs will not be visible from the outside on the Black Pipe or fittings They may be located by examining the inside of the female ends Female Jf Locking Lugs Mill Pac Ll Silicone a jf Male Locking Diagram 1 Lugs muB 0 Note For best results and optimum performance vvith each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may resultin drafting or performance issues not covered under warranty Silicone red RTV is optional b Horizontal runs of vent must be supported every 3 feet 0 9me
46. e fireplace to the outside of the building allowing the fireplace to be operated with less heat entering the room The kit may be used on either the left or right side HEARTH A hearth is not mandatory but is recommended for aesthetics and for added safety Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION CLEARANCES The clearances listed belovv are Minimum distances unless othervvise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials t is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearance to Combustibles from Back 0 0mm Side o 0mm Floor 0 0mm Minimum Clearance from Top of Front Facing Mantel min 8 203mm Ceiling 39 990mm from top of front facing above louvers Side Wall 6 152mm Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Alcove Clearances Max Depth 36 914mm Min Width 60 1524mm Min Height 80 2032mm The top back and sides of the fireplace are defined by standoffs The metal ends of the standoff may NOT be Caution Requirements recessed into combustible construction Min To Ceiling 39 990mm Top of Front 41 1041mm Fire hazard is an extreme risk if these clearances air spa
47. e most current edition of NFPA 54 as adopted by the Board and 2 Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling building or structure used in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instructions provided by the manufacturer for installation of the equipment and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system components and 2 A complete parts list for the venting system design or venting system d MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions e A copy
48. e or additional information consult a qualified installer service agency or gas supplier A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water E This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air CAUTION Hot while in operation Do not touch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and otherl
49. e used with vinyl siding measure to outside surface of wall without siding and add 2 inches Alternate Horizontal Termination Alternate Snorkel Termination Cap Part 1282 14 Part 1281 36 Vertical i Terminal Part Storm Collar Part 1253 Vinyl Siding Flashing 1243 or 1243S Standoff Optional Part 1250 Ceiling Firestop l Part 1263 Horizontal Termination Cap Part 1285 Pipe Length 2 VVall Thimble NK Part 1247 A Adj Pipe Length C 11 14 5 8 45 Elbow S Flat Wall Installation jus Wall Thickness Vent Length H M Required 5 1 2 wow Tv EI 15 23 1 2 1 11 14 5 8 Adj Pipe SIMPSON DURA VENT VENTING Part Description 1208B 6 Pipe Length Black 1207B 9 Pipe Length Black 1206 12 Pipe Length Galv 1206B 12 Pipe Length Black 1204 24 Pipe Length Galv 1204B 24 Pipe Length Black 1203 36 Pipe Length Galv 1203B 36 Pipe Length Black 1202 48 Pipe Length Galv 1202B 48 Pipe Length Black 1211B 11 14 5 8 Adi P L Black 1217B 17 24 Adi Length Black COMPONENTS LIST Part Description Part Description 1245 459 Elbovv Galv 1281 Snorkel 36 Rise Term Cap 1245B 45 Elbovv Black 1240 Wall Thimble Suprt Box 1245G 459 Elbovv Svvivel Galv 1241 Cathdrl Clng Sprt Box 1245BG 45 Elbovv Svvivel Black 3951 Brass Trim for VVall Thimble 1290 909 Elbovv Galv Ceiling Support 1290B 90 Elbow Black 1263 Firestop Spacer
50. eal www mtlfab com 12 305mm 13 330mm 22 11 16 576mm 24 610mm 21 7 16 697mm 31 1 16 789mm 36 914mm 29 13 16 757mm 39 7 16 1002mm 48 1219mm 38 1 4 972mm 47 7 8 1216mm NOTE Horizontal runs of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present a possible fire hazard 16 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION SIMPSON DURA VENT DIRECT VENT GS SYSTEM and Regency DIRECT VENT SYSTEM FLEX Propane amp Natural Gas The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 45 and one 90 elbow two 45 elbows equal one 90 elbow Note Must use optional rigid pipe adapter Part 770 994 when using Simpson Dura Vent pipe Refer to Simpson Dura Vent Venting section Simpson Dura Vent 5 inner diameter 8 outer diameter Regency Flex Vent 5 inner diameter 8 outer diameter Horizontal Feet 0 2 4 6 8 10 12 14 16 18 20 me ll lll ld 1 1 I I I I 1 I I 16 1 l 1 1 Mm lt mn 4 1 1 l Bm 14 77 1 R 1 q l fm l z gt l Ki 1 Le l Ka D o X bs E gt GR I fr A vent guard should be used whenever the term
51. eoo A jueueuued jex1euueye ue ui paesu eq Aew pue ejejd Dune y uo 566 ed y uj sn JO uo si eoueirdde siu epeue ui p1epuejs eujoH llqOVM HIN 0722 VSO NVO Ui pue VLOG Vd3N ISNV Seniunuuo pue sels suone jejsu euo peunjoejnue N JO eue LS 14 40 pyepuejs JUNIO Y Jo 0826 Hed 449 YZ eni pjepuejs Ajejes pue uononJjsuo SWOH peJunjoejnue A pue suomnonJsur uonej ejsul s Je4njoejnueuJ y uM 99uepJoooe ul paesu eq jsnuJ eoueiddy uejs S 1U9A JOOJIG SIU uonej e su euioH peJnjoejnue w 404 L 6p dg VSO S pO suonejjejsu euedoJg pue sec IEIDIEN JO YS Vel 1N 1 ZZZ ISNV 9po2 ses Jang fEUOHEN v Suou Jl Aue JI Sepoo e90 UNA 99UepJ099 Ul palesu eq jsnuJ eouerjidde 5141 ONILIN3SA suon n nsul 104 j enuey uononuajsu ees apne Ge ZZE On 00St 0 uojes wnwxew enbyuojeo 1090 MA9O VL ung 00087 jn Gut WNWIXe ululgc eyuozuo Um ee 2777577 uojes wnwjuju nbiloleo q d Wu 1972 8 000 92 mdu unulul S o uup9 Z L Z doLjejuozuoH SI 400p SUE Jey 13009 Jnejoefui ep Jnepueuc SING LV ezis eoyuo amp EE sb ld TV45 4004 sseq jueujeddeuoo p eun nqn e e uoissaJg ed ZOOM 46 C NO 9 DIOUUEIW 9 cb uuuezeoz 08 1uBieH ui A Q jueuieddeuoo p eun nqn e e uoisseJd Edy v4 ZIOM SLE uBiu eunsseJd plolueiy 12 5 1 uunulluluu u
52. g ES SE Gasket x Louver Mounting SE are different Bracket IU Glass doubled Gasket 7 Correct nt Door Glass Gasket gap 3 Open the bottom louver Pull the Burner Installation ON OFF control box from inside the bottom of the fireplace Using the 2 screvvs on the S Diagram 2 louver secure the control box in place Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd and 3rd spring See diagram 3 View from Rear Pull hook forward and up into slot on door bracket Diagram 3 NOTE Springs must always be OVER not under the gas line Screws on Burner ON OFF louver bracket control box To remove the flush door reverse the above steps 34 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option The optional Bay door is an overlay on the flush front The standard flush door and glass must remain on the unit 1 Unhook the 2 spring loaded hooks from the bottom of the flush door 2 Hook the top of the bay door over the flush door flange and swing the bottom against the bottom flange of the flush door Bay door flange Bay door Bottom of Bay Door shown ff v Bay Door 3 Securetothe flush door bottom bracket with 2 screws provided 4 Reconnect the 2 spring hooks securing
53. ick Panel Base Right 6 430 129 Receptacle Box Mount 7 910 429 Box Receptacle 370 901 Brick Panel Set Standard Brovvn 8 910 428 Duplex Receptacle 370 902 Brick Panel Set Standard Red 9 910 430 Cover Receptacle 370 903 Brick Panel Set Herringbone Brown 10 904 687 Clamp Connector 54 Brick Panel Back 20 370 037 Top Nailing Strip 55 Brick Panel Left 21 370 038 Side Nailing Strip 56 Brick Panel Right 57 Brick Panel Top 22 370 015 Baffle Plate 946 556 Optional Heat Wave Duct Kit 23 780 011 Standoff Top 89 946 004 Junction Box 24 780 013 Standoff Side Back 90 946 000 Round Duct Adaptor 91 946 002 Round to Oval Adaptor 27 Outer Flue Collar 92 946 001 Oval Duct Adaptor 28 Inner Flue Collar Assy 93 946 007 Angle Bracket 29 Flue Mounting Plate 94 946 517 P Fan Assembly HeatWave Option 30 Gasket for Flue Collar 95 946 006 Grill Plate White 96 946 005 01 Wall Adaptor Plate White 35 Thermodisc Bracket 97 910 417 Knob White 98 910 366 Switch Cover Plate White 38 910 241 Switch Burner ON OFF 3 way 99 910 412 Fan Speed Controller 910 899 Wire Harness Valve to Burner 100 910 367 Box Plastic Switch Receptacle 432 917 Fan amp Speed Control Assy 120 Volts Optional 101 690 022 Cover Plate Outer Box Side 102 946 010 Flexible Air Duct 42 910 331 P Fan Motor 946 011 Insulation 6 dia x 24 432 966 Fan Switch Assy 120 Volts Optional 946 570 Heat Release Duct Kit Optional
54. ination is lower m p than the specified minimum or as 4 l p per local codes SE EE m 43 1092mm Note Regency Direct Vent System UNE Minimum Flex is only approved for Height horizontal terminations Requirement o Y e Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 17 INSTALLATION Horizontal Venting with Two 2 90 Elbovvs One 90 elbow Two 45 elbows option v Him ge With these options maximum total pipe lenath 16 40 feet B 2 Min Min 4Max Max 1 of 6 bie Per et vertical and maximum 8 fee vm foot between 90 elbows is quired Horizontal Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows Option H V H H1 H2 SE with min of 11 feet total naue 77 Horizontal Venting with Two 2 90 Elbows One 90 elbow Two 45 elbows Option H v Inn With these options max total pipe length is m total vertical and max 8 feet total horizontal i FRONS between 90 elbows is 18 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Horizontal Venting vvith One 90 elbow Two 45 elbows me v n vevi ues Wi
55. iquids having flammable vapors away Keep burnerand control compartment clean See installation and operating instructions accompanying appliance LIGHTING INSTRUCTIONS STOP Read the safety information above on this label FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK BOXES 1 Push in gas control knob slightly and turn clockwise w to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force PILOT BURNER VEILLEUSE THERMOPILE ELEMENT Gas Inlet fit THERMO taee ELECTRIQUE 2 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow step B in the Safety Information above on this label If you don t smell gas go to the next step 3 Turn knob on gas control counterclockwise Y to PILOT 4 Push in control knob all the way and hold in Continually push and release the black button on spark igniter until pilot lights Continue to hold the control knob in for about 1 2 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 1 to 4 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 5 Turn gas control knob counterclock wise to ON 6 Use rocker switch to operate main burne
56. its specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten S I T VALVE DESCRIPTION 1 Gas on off knob 2 Manual high low adjustment 3 Pilot Adjustment 4 Thermocouple Connection option 5 Outlet Pressure Tap 6 Inlet Pressure Tap 7 Pilot Outlet 8 Main Gas Outlet 9 Alternative TC Connection 5 6 Point 26 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION CONVERSION KIT FROM NG TO LPG PART 372 969 for P48 2 SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF INDOUBT DO NOT DO THIS CONVERSION Each Kit contains one LPG Conversion Kit and one DC Sparker Kit LPG Conversion Kit Contains Qty Part 904 434 918 590 908 529 910 037 918 478 Description Burner Orifice 47 Decal Converted to Propane 5 32 Allen Key LP Injector Pilot Orifice Instruction Sheet DC Sparker Kit Contains Qty Part 1 1 1 1 2 820 475 820 476 904 153 904 330 904 531 904 543 904 553 910 073 910 074 910 078 910 199 910 903 918 478 904 781 904 782 Description Bracket DC Sparker Bracket DC Sparker Washer 8 External Star Nut 8 32 Hex Bushing Split Plastic 0 500 in Screw 8 32 x 3 4 Pan Head Screw 8 x 1 2 Type B Black Oxide
57. led on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 a 1 through 4 b EXEMPTIONS The following equipment is exempt from 248 CMR 5 08 2 a 1 through 4 1 The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in th
58. louvers TO REMOVE THE FAN 1 Shut the power off 2 Reverse the above instructions NOTE The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle 40 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with the glass removed 5 Verify that the venting and cap are unobstructed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned 8 Theunit should never be turned off and on again without a minimum of a 60 second wait Inlet 0 Tap Outlet 5 gt Ta p Pilot Hi Lo Adjustment LIGHTING PROCEDURE IMPORTANT To ignite or reignite the pilot you must first release the tension springs below the door Only when the pilot holds without pressure being applied to the control kn
59. n EE 26 Gas Pipe Pressure Testing 26 54 T Valve DeSstcTip ofhi e ooo 26 Conversion Kit from NG to LPG Part 2372 969 27 Brick Panels InstallatlOft EE 30 Log 11 5 31 standard ME EC EE 34 EIUS LoUVets a a baba 34 Optional FUSH tr ln Sc iier vb Du rb em td otc n a acd 34 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace Optional Bay DOO EE 35 Optional Bay Trim 35 Bay LONUVeT Hl 35 Optional Finishing Trim 36 Double Screen Door 36 Optional Remote Control 37 Optional Wall 5 5 37 Optional Wall Thermostat 37 Wining Diagrams e sa Dam EE 38 Installing The Optional Fahn 40 To Remove the 55222 40 OPERATING INSTRUCTIONS Operating Instructions 41 Shutdown 41 T L T 41 Lighting Procedure 41 Aeration Adjustment aannannannnnnnennannennennnnnnnennnnennne 41 Normal Operating Sounds of Gas Appliances 42 MAINTENANCE Maintenance Ins
60. ng terminals shall not be recessed into a wall or siding 7 Any safety glass removed for servicing must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Weargloves and safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by an authorized service person Aprofessional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm INSTALLATION CHECKLIST 1 Locate appliance a Room location Refer to Locating Your Gas fireplace section b Clearances to Combustibles Refe
61. ns below carefully and refer to the dia grams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot opera tion The gas log kit Part 370 930 contains the following pieces a 02 83 02 84 02 85 02 86 02 87 02 88 02 89 02 90 o 2 3510 C O0 W 902 154 Embers Lava 902 179 Vermiculite 946 669 Platinum Embers supplied with packaged manual LOG SET INSTALLATION Center Cross Log Right Side Cross Log Front Left Side Log Front Right Side Log Left Side End Log Rear Log Middle Right Side Log Right Side End Log 4 Place Log 02 85 on the front left side of the burner Position the right end of the log into the pin on the burner and rest the left end of the log between the st If you will be installing the optional brick panels install them grate post and the front tab prior to installing the logs 02 88 02 90 1st Grate Post Tab in The 02 reference numbers i e 02 83 5 Line up the two holes on the underside of Log 02 86 are molded into the rear of each log with the 2 pins on the right side of the burner and posi tion into place 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Sprinkle the vermiculite all over the top of the base brick panel 3 Line up the two holes on the underside of Log 02 88 wi
62. o or include paint door or glass gasketing or trim At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit FPI has no obligation to enhance or modify any unit once manufactured ie as products evolve field modifications or upgrades will not be performed FPI will not be liable for travel costs for service work Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy Embers rockwool gaskets door handles and paint are not covered under the terms of this warranty policy Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy The warranty will not extend to any part which has been tampered with or altered in any way or in our judgment has been subject to misuse improper installation negligence or accident spillage or downdrafts caused by environmental or geographical conditions inadequate ventilation excessive offsets negative air pressure caused by mechanical systems such as furnaces fans clothes dryer etc Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer FPI will not be liable for acts of God or acts of terrorism which cause malfunction of the appliance Performance problems due to operator error will not be covered by this warranty policy Pro
63. ob reapply the tension springs to the door The unit must not be operated with the tension springs unattached NOTE For all propane units and units equipped with electric spark boxes see Copy of Lighting Plate Instruc tions section for more details IMPORTANT Gas on off knob cannot be turned from PILOT to OFF unless it is partially depressed 1 Turn burner OFF using ON OFF switch 2 Turn gas control knob so indicator points to OFF position and allow 5 minutes for any gas in the combustion chamber to escape 3 Turn gas control knob counterclockwise so indicator points to the PILOT position Depress the gas control knob fully Depress the igniter button several times until the pilot lights After approximately one minute release the gas control knob The pilot flame should continue to burn If the pilot does not remain lit repeat operation allowing a longer period before releasing gas control knob 4 When the pilot stays lit turn the gas knob further counterclockwise to the ON position 5 Use the wall switch thermostat or remote control to turn on the unit 6 Rotate the flame height regulator to adjust the flame height higher or lower SHUTDOWN PROCEDURE 1 Use the wall switch thermostat or remote control to turn off the main burner 2 Turn the main gas control clockwise to the OFF position to turn off the pilot 3 Turn off all electric power to appliance if service is to be performe
64. of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment all venting instructions all parts lists for venting instructions and or all venting design instructions shall remain with the appliance or equipment at the completion of the installation Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 5 INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The P48 NG2 P48 LP2 Direct Vent Fireplace must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIG
65. onejueuuje p UOlSS Lc 644 Oo0EIOM AZl oinssoid iddns ulnullulyy S9DUBILI D AO V 247 894 l pol 31304 32113 4 3NVdO ld 779 NV LNVNNOLLONO ll3siVddV Cd T8yd I9PoIN 4NVdOdd Duioe J apis woud 92ueJe9 2 IeM 9p S wwgoz 8 uy v e 2161 0 CO 00 7 0 epniniv uojes wnwxew anbyojeg q MAE vL ums 00019 jndui unuuixeqw 9 yun Jo pue woyoq sepis d l uoJes uunuuiuiuJ enbuuoj eo jyqeq MJ 678 u mg 000 62 nd l E ii S lqisnquloo Bullies Jnojoefui ep Jnepueuc 9 0 120 ZIS sseq jueujeddeuoo p eunjnqn e e uoissaJg 57 ub p NO eJnsseJd pjojiuey 9 RA ddeuo p eunjnqni e e uoissaJgd Edi 46 0 u3 ublu eunsseJd ploluP N s lq snqusoo XDEUSIEW eq 3usureBeBoq SOOO L L SU So so qnsnquio2 o se2ueJe9 2 ulnulluli LUNWIUILU UOheE u IE D uoisseJd 6492 L OM eJnsseJd j ddns uunullulyy Z N 8 d l poyi 31304 3413 YNOd NONOD O 3779 Lead YALAV S3INOH ZV TVYunIVN nv INVNNOLL NO4z lasVddV C N 8rd I PON SV9 IVYNLVN ITION GAYNLOVANNVW NI GATIVLSNI 38 AYN yood eunp 00L6S80 97r ON H d d soe 002 46612 90 6002 488 LZZ ISNV 9 eoe deJi4 sec pejueA R A NH MH L6IW ZLZ VOO NVO s pniniy UBIH 1v esf 104 seouel ddy pasi4 sed oi H S 9p ON 7 ON lEH S W S N pue vavNvo anod peyn4e2 3113 113
66. ow Swivel Galvanized 45 Elbow Swivel Black 90 Elbow Galvanized 90 Elbow Black 90 Elbow Swivel Galvanized 90 Elbow Swivel Black 90 Starter Elbow Swivel Galvanized Adaptor Ceiling Support Cathedral Support Box Wall Support Band Offset Support Wall Thimble Black Wall Thimble Support Box Ceiling Support Firestop Spacer Trim Plate Black S8DVA 06 58DVA 06B 58DVA 09 58DVA 09B S8DVA 12 58DVA 12B 58DVA 18 58DVA 18B N A from FPI 58DVA 24 58DVA 24B 58DVA 36 58DVA 36B 58DVA 48 S8DVA 48B S8DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from FPI 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 58DVA E45 58DVA E45B Disc See 58DVA E45 Disc See 58DVA E45B 58DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A 58DVA DC S8DVA CS S8DVA WS S8DVA ES N A from FPI SSDVA VVT 58DVA DC N A from FPI 58DVA FS S8DAV WFS Regency P48 2 Zero Clearance Direct Vent Gas Fireplace Simpson Direct Vent GS Discontinued 1208 1208B 1207 1207B 1206 1206B S8DVA 18 58DVA 18B N A from FPI 1204 1204B 1203 1203B 1202 1202B 98DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from FPI 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 1245 1245B
67. per local installation codes Do not insulate the fireplace itself 203mm a Outer 4 The unit does not have to be completely enclosed in a chase The lt clearance on top ofthe unitfrom the top standofis is 0 so combustible building materials can be laid directly on top of the standoffs You lS P z e GO O must maintain clearances from the vent to combustible materials See N O Clearances section Combustible materials can be laid against the side and back standoffs and the stove base 48 1 2 1226mm Heat Wave The HeatW D Kit has diff 8 e HeatVVave Duct Kit has different 9151 2 2070mm clearance and framing requirements check the HeatWave manual for details When installing the unit with any vertical venting off the top of the unit as shown the minimum framing depth changes accordingly Min 29 3 4 756mm q 5 1 4 28 1 2 133mm 724mm 10 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position TOP STANDOFF ASSEMBLY The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Takeeachstandoff and bendintothe correct shape Bend
68. pplicable to local codes The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 This appliance may only be installed in an aftermarket permanently located manufactured U S A only or mobile home where not prohibited by local codes This appliance can only be used with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Ensure that structural members are not cut or weakened during installation NATIONAL e F RE ACE We recommend that our products be Ni installed and iced by prof 1 is DE who are certified in the U S by the ONE REGENCY ONE TREE Y e P e National Fireplace Institute NF For each Regency sold or in Canada by Wood d ERTIFIE Energy 157 Technical Trainin or CERTIFIED Training WETT Viz 2 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace TABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal su KRKN EN NNKNRR KKK 4 REQUIREMENTS MA Code CO Detector for the State of Massachusetts only 5 INSTALLATION Important Message 6 Before YOU Sta EE 6 General Safety Information 6
69. r FOR ALL PROPANE UNITS AND UNITS EQUIPPED WITH ELECTRIC SPARK BOXES 1 Push in gas control knob slightly and turn to PILOT position 2 Push in control knob all the way and hold in until the pilot lights up Continue to hold the control knob in for about 20 seconds after the pilot is lit Release knob 5 Gas Inlet D TO TURN OFF GAS APPLIANCE 1 Turn off the flame switch 2 Push in the gas control knob slightly and turn clockwise to OFF Do not force 3 Turn off all electric power to the appliance if service is to be performed You may shut off the pilot during prolonged non use periods to conserve fuel 3 Push in gas control knob slightly and turn to ON position 4 Turn ON the flame switch Regency P48 2 Zero Clearance Direct Vent Gas Fireplace MAINTENANCE MAINTENANCE INSTRUCTIONS 1 Alwaysturn offthe gas valve before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3 The heater is finished in a heat resistant paintand should only be refinished with
70. r to Clearances section c MantleClearances Referto Combustible Mantel Clearances section d Framing amp FinishingRequirements Refer to Framing amp Finishing section e Venting Requirements Refer to Venting section 2 Assemble Top Standoffs and Top Facing Support and Side Nailing Strips Refer to UnitAssembly Priorto Installation NOTE Must be done before installing unit into place 3 Install vent Refer to Venting Arrangement sections 4 Make gas and electrical connections Test the pilot Must be as per diagram Refer to Pilot Adiustment section Convert to propane if desired Refer to Conversion from NG to LPG section 5 Test Gas Pressure Refer to Gas Pipe Pressure Testing section Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION 6 Install standard and optional features Refer to the following sections a Brick Panels Installation b Log Set Installation C Standard Flush Door d Flush Louvers e Flush Trim f Bay Door g Bay Trim h Bay Louvers i Finishing trim j Double Screen Door k Remote Control l Wall Switch Wall Thermostat n Installing the Fan 11 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer This includes 1 Clocking the appliance to ensure the correct firing rate rate noted on label 51 0
71. rs our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards VENTED GAS FIREPLACE HEATERS ANSI Z21 88b 2003 CSA 2 33b 2003 and GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN CGA 2 17 M91 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated Z8 Ground Lug for attachment of the ground wire to the steel chassis as a
72. s or Bay Louvers and the Flush Front or Bay Front prior DOOR to installing the Finishing Trim 1 Pull out the top louver 1 Install the Finishing Trim sides as shown in the diagram line up the holes in the side trim with the holes in the firebox side 2 Center the screen door and hook over the flush door 2 Secure with 2 screws per side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure Finishing Trim Top Finishing vi Trim Side 3 Open the screen door s and secure the screen door to the flush door front vvith 2 clips on the bottom left and right side Finishing 71 Trim Side Clip installed on right side 36 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION OPTIONAL REMOTE CONTROL Can be used with Option 2 or 3 but not both Usethe Regency Remote Control Kit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the fireplace to that location Use the Thermostat Wire Table 2 Connectthe two wires
73. se ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the switch contacts closing and is normal Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process 42 Copy of the Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 Australia AG601 New Zealand NZS 5261 WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistanc
74. stic Install the vertical termination cap by twist locking it Note Any closets or storage spaces which the vent passes through must be enclosed 24 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION UNIT INSTALLATION with Regency Direct Vent System Flex 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut a 11 279mm hole in the wall inside dimension Note A top clearance of 2 1 2 64mm and side amp bottom clearance of 1 1 2 38mm must be maintained exceptthatonly a 1 25mm clearance is needed at the termination end We recommend framing a 11 279mm x 11 279mm inside dimensions hole to give structuralrigidity for mounting the termination Note To make out the installation 7 7 E MA more aesthetically pleasing we recommendframing 2 outasquareto mount the terminal to Note If installing termination on a siding covered wall furring strips must be used to ensure that the termination is not recessed into the siding 2 Levelthe fireplace and fasten it to the fram ing using nails or screws through the nailing strips 3 Assemble the vent assembly by applying Mill Pac to the 5 127mm inner collar of the termination and slipping the 5 127mm liner over it
75. sufficient size to meet the minimum requirements for clearance to combustibles of 1 1 4 32mm Slip the flashing under the shingles shingles should overlap half the flashing as per Diagram 4 Diagram 4 The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments 6 Continue to assemble pipe lengths Note If an offset is necessary in the attic to avoid obstructions it is important to support the vent pipe every 3 feet 0 9 meter to avoid excessive stress on the elbows and possible separation Wall straps are available for this purpose Diagram 2 Galvanizedpipeis desirable abovethe roofline duetoits highercorrosionresistance Continue to add pipe sections through the flashing until the height ofthe vent cap meets the minimum height requirements specified in Diagram 5 or local codes Note that for steep roof pitches the vertical height must be increased over 12 12 to 14 12 over 14 12 to 16 12 over 16 12 to 18 12 over 18 12 to 20 12 over 20 12 to 21 12 7 8 A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the vent height may solve the problem 2 2 2 2 5 4 5 7 1 5 us Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide storm collar over the pipe section and seal with a ma
76. t side of the grate Rest the front edge za 5 ee a of the log in the notches on Log 02 85 Tab Cut out on the underside of the log Position the cut out onto the grate bar Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 33 INSTALLATION STANDARD FLUSH LOUVERS FLUSH DOOR 1 Install the top louver by sliding the two l bracket clips into the brackets located The standard flush door comes with a black underneath the top of the firebox frame To install the frame simply hook the top door flange onto the top of the unit and swing 2 Install the bottom louver by folding the louver the door towards the unit diagram 1 down and then sliding the Bottom Louver bracket down onto the 2 pins on the base of the unit diagram 1 Secure with 1 screw as per diagram 2 x DMIOEE Bottom Burner ON OFF control box attached to Louver Brace 5 bottom flush louver Bracket OPTIONAL FLUSH TRIM Attach the round magnets to the back of the Hook top of 5 top trim piece and to the bottom trim piece p rang Diagram 1 Diagram 2 then attach trim to the top and bottom of Flush door Top Louver Flush Bracket Door Diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit Diagram 2 ncorrect er
77. ter Wall straps are available for this purpose 5 Mark the wall for a 11 x 11 279mm x 279mm square hole The center of the square hole should line up with the center line of the horizontal pipe Cut and frame the 11 inch 279mm square hole in the exterior wall where the vent will be terminated If the wall being penetrated is constructed of non combustible material i e masonry block or concrete a 8 203mm diameter hole is acceptable center of hole i G cD 2 Zs E Diagram 2 Note a Thehorizontal run of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal vent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed For External Vent Terminal Locations see diagram in Exterior Vent Termination Locations section 6 The arrovv on the vent cap should be pointing up nsure that the 1 1 4 32mm clearances to combustible materials are maintained Diagram 5 Install the termination cap Note If installing termination on a siding covered wall a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding Siding Y apply sealant to all four sides
78. th the 2 pins at the rear of the grate and position into place _ 02 88 5 E Pins Pins Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 31 INSTALLATION 6 Embers should be placed in front of Log 02 85 and 8 Line up the hole on the underside of Log 02 84 vvith Log 02 86 the pin on Log 02 86 and position the notch on the bottom of the log into the last grate post Separate platinum embers and place around the em bers at the front of the burner Avoid stacking platinum embers Sa ch Pin in Log Last Grate Post Embers 9 Place Log 02 89 against the notch in Log 02 84 Rest CAUTION DO NOT cover burner ports with embers the notch at the end of the log against the grate 7 Place Log 02 83 onto the pin in Log 02 88 and position the notch on the bottom of the log into the 4th grate post Ze dE SC gemenge Ka e E ane F Farina T eg ox a Rest log ori the pin Notch Rest notch at the end of in Log 02 88 the log against the grate Ath xum Post Position the notch on the bottom of the log into the 4th grate post 32 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION 10 Place Log 02 90 onto the right side of the grate Posi 11 Place Log 02 87 on the middle left side of the burner tion the cut out on the underside of the log onto the Position the bottom rear of the log against the rear grate bar tab on the lef
79. th these options max total pipe length is 30feetwith min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90 elbows is required Vertical Venting with Two 2 90 Elbows One 90 elbow Two 45 elbows A max total pipe length is i 30 feet with min of 6 feet in total vertical and max 8 feet total horizontal Please note min 1 foot in between 90 elbows is required 2 3 5 7 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace Three 3 90 Elbovvs CO Vertical Venting with Two 2 90 Elbows One 90 elbow Two 45 elbows Option nrm v With these options max total pipe length is 30 feet with min of 6 feet total vertical and max 6 feet total horizontal Please note min 1 foot between 90 elbows is required 19 INSTALLATION Vertical Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows max total pipe length is 20 feet with min of eum and max 7 feet total 5 m aee between 90 elbows is 86 6 V Vertical Venting with Three 3 90 Elbows QO One 90 elbow Two 45 elbows EM gu total pipe length is 30 feet with min of 10 feet tota ym 2 total horizontal Please note min 1 foot between 90 elbows is 20 Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLAT
80. the flush door 5 Slide the valve extension knobs onto the valve knobs Shut Off Ext Knob HUL o Ext Knob Note If any maintenance etc must be done in the firebox first remove the Bay louvers and door OPTIONAL BAY TRIM Attach the supplied magnets each to the back of the top and bottom trim pieces and attach trim to the top and bottom of Bay door See diagrams 3 and 4 Magnets Trim Diagram 3 Bay door flange Bay door Diagram 4 Screws on louver BAY LOUVERS 1 Install top louver by sliding the two bracket clips into the brackets located on top of the bay door See below The fitted louver leaves a small gap between faceplate bottom and louver top Top Louver Louver Bracket Louver Bracket Note Top and bottom louvers and brackets are different 2 Install bottom louver by sliding the two bracket clips into the brackets located underneath the bay door Install bottom louver by sliding the two bracket clips into the brackets located underneath the bay door and secure with 1 screw on each end 3 Open the bottom louver Pull the Burner ON OFF control box from inside the bottom of the fireplace Using the 2 screws on the louver secure the control box in place Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 35 INSTALLATION OPTIONAL FINISHING TRIM DOUBLE SCREEN NOTE Remove both the Flush Louver
81. tible mantel leg clearances as per diagram eg PASS Fireplace CHE i OON E Na R A Maximum A 1 1 2 projection at 3 T minimum clearance d EE eo T ff ar rur ur rr ur ur 3 EE WV 777 SS v 6 ii Allowable mantel leg projection Regency P48 2 Zero Clearance Direct Vent Gas Fireplace INSTALLATION 1 2 8 Di FRAMING amp FINISHING Determine the total thickness of facing material eg drywall plus ceramic tiles to allow the finished surface to be flush with the front of the unit Total facing thickness can vary from 1 2 13mm to 1 1 4 32mm thick Frame in the enclosure for the unit with framing material The framed opening for the assembled kit is 47 1 2 high x 48 1 2 wide x 26 1 4 deep 1207mm H x 1232mm W x 667mm D See Diagram 1 See important note below when installing with any veritical venting off of the top Min 26 1 4 667mm 11 279mm dia hole through wall for flex T ny 1 e SE 5 127mm a 3a 26 1 4 Outside 667mm Finished Wall 1193m 4 b Min 30 762mm Opening for gas o Note 43 1092mm is the minimum height for flex termination and 34 1 2 Simpson Dura Vent terminations 876mm 06 o 1 2 mm 3 For exterior walls insulate the enclosure to the same degree as Dia Inner the rest of the house apply vapour barrier and drywall as
82. trips as vvas used for the Top Facing Support Attach each side nailing strip using 3 screvvs VENTING INTRODUCTION The P48 2 uses the balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separate vent system Common vent systems are prohibited Regency P48 2 Zero Clearance Direct Vent Gas Fireplace 11 INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS SeoueJeej jueJaJiip eJinbeJ Aew suone nB98J JO sepoo E901 9 ON pO uonejjeisu ep g V ui peyioeds sy pej eysur eq IlEUS puen6 peunJeo e e qisseooe s uoneuliuue JUBA U OOlI y ujeaueq sepis OM JO uinuuluiuJ e uo uedo An si uoojeq Jo y p uoJod epueJeA Ji peniuued IUO sBui aMp ujoq seAJes pue sHhuljjamp A wey juis ow U M Q D TEOO si YOIUM eMeAuUp pared Jo yjem p s e e oqe Anen ejeuluuJe JOU EUS 1 V WU9QG E7 Ulul Auoo eq Jo Xoep uoJod epueJeA sapun 0
83. tructions 43 General Vent 2 43 Log Replacement 43 Thermopile Thermocouplle 43 Glass askeri Em 43 Gold Plated Louvers amp Trim 43 Reie 44 Glass Replacement 44 Bay Glass Replacement 44 installing ValVe ana asa as l 44 Removing Valve 45 PARTS LIST Main ASSembiy u ab a daban 46 Burner amp Log Assembiy 48 Flush Door amp LOUVers ie e Er 49 Bay Front amp Louvers 50 WARRANTY WATAN coser xe 51 3 SAFETY LABEL Een mm B S m m mm pm e pm rm pm rm em zm pm rem rm pm rm rm rm rm rm mm rm II SS rm rm rm rm rm 209 816 epeue Dg eyeq pr jeuoneujJeju 510 eoejdaulJ jd epeue ne nbuqe epeue Ul epey SJ93 lJ UNA SN 104 JOU 51 o2ejdauiy 566 sel n pijos Y IM Sn 10 JON Desn SI 11 paleo e ssejun sesef Jeujo YM BSN lq M AUO jou si eoueidde siu sjieyep jenuew S 4 UMO BBS sepoo e90 Aq pejqiuoJd jou llqoul peunjoejnueuu pej
84. up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff securely to the top with 2 screws per standoff on opposite corners 1 Top Standoff after bending SV Top Standoff flat shipping position TOP FACING SUPPORT AND SIDE NAILING STRIPS Determine the total thickness of facing material e g drywall plus ceramic tiles to allow the finished surface to be flush with the front of the unit Total facing thickness can vary from 1 2 13mm to 1 1 4 82mm thick The Top Facing Support amp Side Nailing Strips can be mounted in 3 different positions depending on the thickness of the facing material Screw Facing Material Depth Position 1 2 13mm For C screw position the top facing support is reversed 1 Mount Top Facing Support using the 3 supplied screws into the three pre punched screw holes on the top front of the unit Use hole positions A B or C depending on your facing depth Top Facing Support Side 4 Nailing n Strip Top Facing Support Screw holes for Top Facing V Support p CG Ae Screw holes for Side Nailing Strip C Screw Position Forafacing material depth of 1 1 4 32mm the top facing support must be reversed Top Facing Support is reversed for C hole position 1 2 Use the same screvv hole position for the Side Nailing S
85. xtending the full width and depth of the appliance The P48 2 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A B C D See Diagram 1 Diagram 1 Flat on Wall B Flat on Wall Corner C Recessed into Wall Alcove D Corner 5 This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation The P48 2 Direct Vent Fireplace is approved for alcove installations which meet the clearances listed on this page VVerecommend thatyou plan yourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer revievv your plans before installation Note For vent terminations see Exterior Vent Termination Locations section Heat Wave HEATWAVE OPTIONAL DUCT SYSTEM KIT 946 556 The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home Up to two kits may be installed on the fireplace Please Note Only 1 HeatWave kit may be operated at one time This includes the internal blower option as well OPTIONAL HEAT RELEASE KIT 946 570 The Heat Release Kit expels warm air from th
86. y thereafter Special Finishes One year on brushed nickel and antique copper full screens and doors You can expect some changes in color as the product ages with constant heating and cooling FPI warranties the product for any manufacturing defects on the original product However the manufacturers warranty does not cover changing colors and marks ie finger prints etc applied after the purchase of the product Damage from the use of abrasive cleaners is not covered by warranty Electrical and mechanical components such as blowers switches wiring thermodiscs FPI remote controls spill switches thermopiles thermocouples pilot assembly components and gas valves are covered for two years parts and one year subsidized labour from the date of purchase Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance ie twelve 12 months from original purchase date of appliance with a minimum of three 3 months coverage from date of replacement FPI venting components are covered parts and subsidized labour for three 3 years from date of purchase Simpson Dura Vent venting components Direct Vent units are covered by Simpson Dura Vent Inc warranty Repair replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No la
Download Pdf Manuals
Related Search
Related Contents
GE JSP39SKSS Stainless Steel Electric Kitchen Range HP LE1902x User's Manual Avaya 1416 IP Phone Quick Reference Guide Pioneer GM-X862 Stereo Amplifier User Manual Installation & User Guide - Axxess Identification Ltd GE wpsf4170 User's Manual Harman Kardon Aura Quick Start Guide VL-08ZF の取付工事説明書を見る CFS-32GBM-A 取扱説明書 Copyright © All rights reserved.