Regency LIBERTY L900-LP User's Manual

image

Contents

1. INSTALLATION BACK UP BATTERY INSTALLATION within Power Module Z Op The 9V battery operates the rear burner under power outage conditions 5 The AA battery operates the DC Sparker for lighting the pilot m gt 3 O 1 Remove the glass door 2 Loosen the 2 screws that hold the left side 4 Unplug the power source Z heat shield in place a Release the 2 door latches on the left 5 Loosen the bottom screw and remove the top screw from the power module and right side at the top of the firebox Heat Shield Latch 6 Cut the cable tie that holds together the wires for the power module and the pull out the power module 3 Lift up and pull out the heat shield slightly 7 Remove the power module cover by to clear the screwheads and then hang it removing the 2 screws one on each side on the top bracket located directly above the heat shield Jo Bracket Swing the door out from the top and release pr f the hinges on the left and right side of the door by lifting them up 3 Hinge Door Heat Shield Place the door on a soft surface to prevent scratching 9 Reverse steps 7 to 1 Regency L900 Direct Vent Gas Fireplace 27 INSTALLATION CONVERSION KIT 546 969 FROM NG TO LP LP Conversion instructions for BEFORE UNIT INSTALLATION THIS CONVERSION MUST BE DONE BY A QUALIF
2. Log Set Installation 5555555 50555 005550055590055990559 Aeration Adjustment EE Wiring Diagram OPERATING INSTRUCTIONS Matching Remote Handset amp Control Box ID Code Operating Instructions LEL EE F gt RER RE EE LIGMUMG Procedure vassere dead OPERATING INSTRUCTIONS Normal Operating Sounds of Gas Appliances Operation During Power Outage Shutdown ProCedUre d kk Copy of Lighting Plate Instructions Maintenance Instructions General Vent Maintenance Log Replacement ezE Thermopile Thermocouple cccccccseeeeeeeeeeeees GS GK Door Glass Glass Replacement 5 555555 555559555 Back Up Battery Replacement EEUE EUEUU UU jLUUL Power Module Replacement Control Module Replacement DC Sparker Replacement Valve Tray Replacement ccccccceecceeeeseeeseeeeeees PARTS LIST Main Assembly Ha Burner amp Log Assembiy UUUEEEE WARRANTY The Warranty Limited Lifetime SAFETY LABEL Copy of Safety Decal 4 REQUIREMENTS MA Code CO Detector for the State of Massa
3. 15 Rigid Pipe Venting Systems 16 Basic Horizontal amp Vertical Terminations 16 5 x 8 Rigid Pipe Cross Reference Chart 17 Venting Arrangements keke 13 Allowable Horizontal Terminations 19 Venting Arrangements 00006006600 kk 22 Allowable Vertical Terminations 22 Unit Installation with Horizontal Termination 23 Unit Installation with Vertical Termination 24 Horizontal Termination with Flex Vent System 25 Hion Elevato Mieren 26 Gas Line InstalatioMN user 26 Pilot AGIUSUMIC IN aki Sates 26 Gas Pipe Pressure Testing UUUU 26 SIT 825 Valve Description 545 555555559555 26 Regency L900 Direct Vent Gas Fireplace DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE ETIQUETTE REGENCY 2 eee eee Serial No No de serie Listed VENTED GAS FIREPLACE HEATER Tested to ANSI Z21 88 2005 CSA 2 33 2005 CAN CGA 2 17 M91 ANSI Z21 50b 2003 CSA 2 22b 2003 Ge Certified for Certifi e pour CANADA AND U S A cil Aus NATURAL GAS FIREPLACE MODEL L900 NG Factory Equipped For Altitude 0 4500ft 0 1372m e Min Supply Pressure 5 WC 1 25 kpa
4. FIREPLACE PRODUCTS REGENCY www regency fire com LIBERTY L900 Gas Fireplace Owners amp Installation Manual Unit requires 120V to operate See Wiring Diagram section in manual for more details Receptacle is included with manual ad 4 a Lan WARNING Ifthe information in these instructions are not followed exactly What to do if you smell gas a fire or explosion may result causing property damage Do not try to light any appliance personal injury or loss of life Do not touch any electrical switch do not use any phone in your FOR YOUR SAFETY building Do not store or use gasoline or other flammable vapors and Immediately call your gas supplier liquids in the vicinity of this or any other appliance from a neighbour s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified If you cannot reach your gas installer service agency or the gas supplier supplier call the fire department Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference 918 610c FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 4 11 14 07 the New Owner Congratulations You are the owner of a state of the art Gas Fireplace by REGENCY The L900 has been designed to pr
5. EE Valve Tray Slightly Removed 19 Disconnect the black and red wires from the solenoid valve 20 Completely pull out the valve tray 21 Replace the valve tray and reverse steps to re install 22 Turn on the gas supply and check for gas leaks 23 Plug in the power source 24 Re install the left heat shield 25 Re install the grate 26 Re install the interior brick panels 27 Re install the log set 28 Re install the glass door 29 Check the inlet and outlet pressures 30 Re install the right heat shield 31 Check operation of flame control 32 Check for proper flame appearance 33 Re install the exterior brick panels 17 Disconnect the 2 red wires and 1 black wire from the valve 12 Carefully remove the bottom brick panel T Modulating Coil Bottom Brick Panel 13 Loosen the 2 screws that hold the right side heat shield Wires 18 Remove the DC Sparker wires 1 wire for Heat the ignitor and 2 wires to the module box Shield 14 Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield Bracket 2 18 Remove the 16 screws that hold the valve tray to the firebox and slightly pull out the valve tray LLI 0 lt lt Z LLI lt Heat Shield 15 Disconnect the inlet gas line from the valve 16 Disconnect the 2 connec
6. SIDE NAILING STRIPS The side nailing strips come attached to the unit There are 3 plates one on the top and bottom that can be folded out as required Side Nailing Strips shown folded out UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position TOP STANDOFF ASSEMBLY The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoffand bend into the correct shape Bend up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff securely to the top with 2 screws per standoff on opposite corners 1 Top Standoff a Top Standoff flat shipping position Regency L900 Direct Vent Gas Fireplace 12 e lt lt o Z INSTALLATION need to use heated room air for combustion and losing warm room air up the chimney VENTING To set the vent restriction as indicated in the Screws for plugging the holes venting arrangements diagrams refer to the all holes must be plugged with a screw INTRODUCTION instructions below e Screw holes for fixing the restrictor plate The L900 uses the balanced flue techno
7. TT dji a Alcove Clearances Fe Ha Min Depth 36 914mm Min Width 84 2134mm 76mm Min Height 84 2134mm Alcove side wall must have a minimum of 16 406mm clearance on one Side WARNING IMPORTANT nile ae j If converting this unit to LP it is highly recommened if these clearances air space to combustible materials are not adhered to It is of greatest importance that this the conversion be done BEFORE the unit is slid into fireplace and vent system be installed only in position for ease of conversion See Conversion accordance with these instructions from NG to LP section for instructions Regency L900 Direct Vent Gas Fireplace 9 INSTALLATION MANTEL CLEARANCES Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of front facing are shown in the diagram below Note Anon combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board 14 12 10 8 6 4 2 0 e lt lt ep Z Note Ensure the paint that is used R on the mantel and the facing is 13 330mm ial or the paint may 25 Drywall 20 3 89mm Reader 5 W on Edge 16 Non combustible 1 25mm Facin 0 2741 2 1844 2 699mm 470mm Standoff 10 17 12 445mm 0 Top of 7 Front i Facing
8. 1 ht Y F i 2 7 oe G a rox er va vw gt REN UR 3 Tab A TAR ban2 Po 0 kr an Base Brick Panel Slot Regency L900 Direct Vent Gas Fireplace 35 INSTALLATION LOG SET INSTALLATION Installation of Interior Brick Panels must be completed before installing the log set Read the instructions below carefully and refer to the diagrams 3 Place log 03 42 on the front left side of the burner Place the right If the logs are broken do not use the unit until they are replaced end of the log into the pin and rest the notch on the left end of the Broken logs can interfere with pilot operation log on the grate Log kit Part No 546 930 and 546 935 contain the following pieces lt 4 lt op Z a 03 41 Log Rear b 03 42 Log Front Left c 03 43 Log Front Right d 03 44 Log Cross Left e 03 45 Log Cross Right f 902 154 Embers Lava g 902 179 Vermiculite 4 Spread some vermiculite on the front log tray next to log 03 42 as shown in the image below Note Do not build up vermiculite as this will cause the next log 03 43 not to sit all the way down Vermiculite is only needed to conceal the metal inbetween the left and right front logs The 03 reference numbers i e 03 41 are molded into the rear of each log 1 Carefully remove the logs from the box and
9. Atop clearance of 3 76mm and side amp bottom clearance of 2 51mm must be maintained except when passing through a wall ceil ing or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm We recommend framing a 11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination Install the vent system according to the center manufacturer s instructions included with the of hole components 1 Set the unit in its desired location Check to NM 5 Screws determine if wall studs or roof rafters are in n Vinyl siding standoff the way when the venting system is attached 9 If this is the case you may want to adjust Wall Thimble the location of the unit Rough in the gas required Diagram 5 preferably on the right side of the unit and L l the electrical junction block is on the left The four wood screws provided should be re side on the left placed with appropriate fasteners for stucco i E l C 9 brick concrete or other types of sidings 2 DirectVentpipe and fittings are designed with 2 li en special IMISI DOK omr connecting D 8 Before connecting the horizontal run of vent venting system to the appliance flue outlet gt C pipe to the vent termination slide the Wall twist lock appliance adaptor is required o 2 Thimble over the vent pipe The wall thimble 3 In conjunction w
10. Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out 5 dia flue pipe with spring spacer pring sp 8 dia air intake Screws Mandatory on all horizontal terminations 25 4 5 6 7 8 9 UNIT INSTALLATION HORIZONTAL TERMINATION WITH FLEX VENT SYSTEM Note A top clearance of 3 76mm and side amp bottom clearance of 2 51mm must be maintained except when passing through a wall ceiling or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm Werecommendframing a 11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut an 11 279mm hole in the wall inside dimension 0 at Fairing ng 1 If installing termination on a siding covered wall a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding Level the fireplace and fasten it to the fram ing using nails or screws through the nailing strips Assemble the vent assembly by applying
11. gt N Clearances section Combustible materials can be laid against the side and back standoffs and the stove base Non combustible Material IMPORTANT If converting this unit to LP it is highly recommened the conversion be done BEFORE the unit is slid into position for ease of conversion See Conversion from NG to LP section for instructions ULL ALLE lt gt 10 5 16 254mm Regency L900 Direct Vent Gas Fireplace 11 INSTALLATION FINISHING TEMPLATE In order to maintain a clean face the L900 allows for a 1 8 in overlap of finishing material such as rock or tile on both the left and right hand sides of the unit top and bottom sides do not allow for an overlap this overlap must not be exceeded or the glass door will no longer open properly Non combustible wall board is installed up to the flanges on all sides of the unit When installing any additional facing material use the Finishing Template included with the unit to ensure that the finishing material does not exceed the allowable overlap The Finishing Template uses two magnets to attach itself to the flange on the left or right side of the unit see diagram below Install the facing material up to the outside edge when facing the unit of the finishing template This template may be discarded after the facing material has been installed
12. 0 NT A 3 ud i Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed Serial No a d 165016 Liberty AstroCap HeatWave Heat Release and FireWizard are trademarks of FPI Fir en Co ight 2007 FPI Fireplace j International Ltd All rights reserved 1 x
13. 5 Slide unit into place 6 Install vent Refer to Venting Arrangement sections 7 Make gas connections Refer to Gas Line Installation section 8 Makeelectrical connections Refer to Wiring Diagram section NOTE Unit requires 120V to operate 9 Test the pilot Refer to Pilot Adjustment section 10 Test Gas Pressure Refer to Gas Pipe Pressure Testing section YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANGE GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes withthe current Canadian or National Gas Codes CAN1 B149 or ANSI 23 1 Installation Codes 2 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and vent should be enclosed 4 This appliance must be connected to the specified vent and termination cap to the outside of the building envelope Never vent to another room or inside 8 building Make sure that the vent is fitted as per Venting instructions 5 Inspect the venting system annually for blockage and any signs of deterioration 6 Venting
14. Release the 2 door latches on the left and right side at the top of the firebox w Heat Shield Latch 5 Unplug the power source 6 Remove the top screw and loosen the bottom screw that hold the power module in place Power Module b Swing the door outfrom the top and release the hinges on the left and right side of the door by lifting them up Door 7 Remove the power module cover by removing the 2 screws one on each side 0 lt lt Z LLI lt 3 Loosen the 2 screws that hold the left side heat shield in place Power Module Heat Shield Power Module with Cover Removed Regency L900 Direct Vent Gas Fireplace 44 MAINTENANCE CONTROL MODULE REPLACEMENT 1 Remove the exterior brick panels 3 Loosen the 2 screws that hold the left side 7 Disconnect the 3 connectors from the heat shield in place control module 2 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox Heat Shield Latch 8 Pull out the control module NOTE The control module is held in place 4 Lift up and pull out the heat shield slightly with velcro to clear the screwheads and then hang it on the top bracket located directly above the heat shield Bracket J Swing the door out from the top and release the hinges on the left and right side of the door by li
15. 4 Diagram 4 The upper half of the flashing is installed under the roofing material and not nailed down until the chimney 5 installed This allows for small adjustments 6 Continue to assemble pipe lengths Note If an offset is necessary in the attic to avoid obstructions it is important to support the vent pipe every 3 feet 0 9 meter to avoid excessive stress on the elbows and possible separation Wall straps are available for this purpose Diagram 2 Galvanized pipe is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Diagram 5 or local codes Note that for steep roof pitches the vertical height must be increased UNIT INSTALLATION WITH VERTICAL TERMINATION Rigid Vent Systems Note A clearance of 2 51mm must be maintained except when passing through a wall ceiling or at the termination where the use of afirestop or wall thimble reduces the required clearance to 1 1 2 38mm We recommend framing a 11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination 1 Maintain the 2 51mm clearances air spaces to combustibles when RS passing through ceilings walls roofs enclosures attic rafter or other nearby of combustible surfaces Do not pack air spaces z with insulation Check Venti
16. Guard is required when the AstroCap is installed above grade at 7 feet or lower e The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications Only the AstroCap XL and Snorkels are certified for horizontal terminations Offset Pipe Selection Use this table to determine offset pipe lengths For specific instructions or details on particular 5 x 8 Venting venting components please visit the following websites 0 0mm 5 11 16 144mm 15 5 16 389mm Pipe Length Selkirk Direct Temp www selkirkcorp com 6 152mm 8 13 1 6 224mm 18 7 16 468 A Metal Fab Sure Seal www mtlfab com 9 229Mm 10 15 16 278mm 0 12 305mm 13 330 22 11 16 576mm e 21 7 16 697mm X 24 610 36 914mm 29 13 16 757 29 7 16 1002 48 1219mm 38 1 4 972 47 7 8 1216mm X gt NOTE Horizontal runs of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present a possible fire hazard 18 Regency L900 Direct Vent Gas Fireplace Z 9 gt Em gt 4 INSTALLATION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90 two 45 elbows equal one 90
17. Pipe Length Black 9 Pipe Length Galvanized 9 Pipe Length Black 12 Pipe Length Galvanized 12 Pipe Length Black 18 Pipe Length Galvanized 18 Pipe Length Black 24 Pipe Length Galvanized 24 Pipe Length Black 36 Pipe Length Galvanized 36 Pipe Length Black 48 Pipe Length Galvanized 48 Pipe Length Black 60 Pipe Length Galvanized 60 Pipe Length Black Adjustable Length 3 10 Galvanized Adjustable Length 3 10 Black Adjustable Length 11 14 Galvanized Adjustable Length 11 14 Black Adjustable Length 17 24 Galvanized Adjustable Length 17 24 Black Extension Pipe 8 1 2 Galvanized Extension Pipe 8 1 2 Black Extension Pipe 16 Galvanized Extension Pipe 16 Black 459 Elbow Galvanized 45 Elbow Black 459 Elbow Swivel Galvanized 45 Elbow Swivel Black 909 Elbow Galvanized 909 Elbow Black 90 Elbow Swivel Galvanized 909 Elbow Swivel Black 909 Starter Elbow Swivel Galvanized Adaptor Ceiling Support Cathedral Support Box Wall Support Band Offset Support Wall Thimble Black Wall Thimble Support Box Ceiling Support Firestop Spacer Trim Plate Black Regency L900 Direct Vent Gas Fireplace INSTALLATION Components from different Manufacturers may not be mixed Not Rigid Pipe components are available directly from FPI Simpson Simpson 5 Selkirk Metal Fab Descri ption Direc
18. Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset To ensure the remote control is matched to the receiver correctly please follow the steps below 1 Ensure that the Remote Control and the 3 way switch located at the appliance are both in the OFF position 2 Ensure that the pilot is lit and the pilot control knob is in the ON position on the appliance 3 Install the 2 x AAA alkaline batteries into the Remote Control 4 Unplug and re plug the power cord The power cord is located on the left hand side of the appliance and will be plugged into the receptacle 5 Switch the 3 way switch located on the ap pliance to the REMOTE position 6 Press and hold the PROG and FAN buttons simultaneously for up to 20 seconds During this time the remote will display LC while it is transmitting codes to the receiver Once it is successfully transmitted one will hear the solenoid click and the burners will come on If is does not work the first time repeat steps 1 6 7 Release both the PROG and FAN buttons The remote will revert back to normal but the burner will still be on 8 Press the ON OFF button on the remote control 2 times to turn the burner off 9 The remote control is now programmed to the receiver and the appliance can now be operated with it The control box will only learn the Remote ID codes during the first 30
19. above paved sidewalk or a paved driveway located on public property min 84 2 1m N Clearance under veranda porch deck or balcony min 33 84cm Note Excluding direct vent or non condensing appliances a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor If the vent termination is accessible a certified guard shall be installed As specified in CGA 8149 Installation Code Note Local codes or regulations may require different clearances In accordance with the current ANSI Z223 1 NFPA 54 Natioinal Fuel Gas Code 14 Regency L900 Direct Vent Gas Fireplace INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION FLEX Regency Direct Vent System These venting systems in combination with the L900 have been tested and listed as a direct vent system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the Exterior Vent Termination Locations section Z 9 gt Em gt 4 FPI Direct Vent Flex System Termination Kits include all the parts needed to install the L900 using a flexible vent 1 946 618 6 Feet 8 flexible liner Kit
20. and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion and ventilation air is not obstructed Note Never operate the appliance without the glass properly secured in place 6 Donotuse this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water 7 In the event this appliance has been serviced check that the vent air system has been properly resealed amp reinstalled in accordance with the manufacturer s instructions 8 Verify operation after servicing GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semiannually Recommended areas to inspect as follows 1 Check the Venting System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes Regency L900 Direct Vent Gas Fireplace 42 Lu O Z 7 Z TI Z gt MAINTENANCE BACK UP BATTERY REPLACEMENT within Power Module 1 Remove the exterior brick panels 3 Loosen the 2 screws that hold the left side 7 Pull out the power module heat shield in place 2 Remove the glass door 8 Remove the power module cover by removing the 2 screws one on each side a Release the 2 door latches on the left and right
21. different clearance and framing requirements check the HeatWave manual for details 11 Install standard and optional features Refer to the following sections Interior Brick Panels Log Set Exterior Brick Panels Remote Control refer to Matching Remote Handset amp Control Box ID Code section 9 0 12 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer This includes 1 Clocking the appliance to ensure the correct firing rate rate noted on label 48 000 NG Btu h 46 500 LP Btu h after burning appliance for 15 minutes 2 Ifrequired adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1 Ensure that structural members are not cut or weakened during installation 2 Ensure proper grounding using the 8 ground lug provided See Wiring Diagram section LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface e g wood metal concrete This may be the floor or raised
22. elbow Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Venting Systems Horizontal Feet 0 2 4 6 8 10 12 14 16 18 20 5 dE S 11111 11 11 l l l AE e vent VE reser 7 4 i on Set 2 0 i y i i 14 p P ye Pi 0 A gt N j E 7 W gt V 68 Da D ia NN ra N 2 l O Poe FK oe pp Vent Restrictor see BE Factory Set 0 wwe 00 gt 4 76 1930mm 2 Minimum Height A Vent Guard is required when the AstroCap Requirement 5 is installed above grade at 7 feet or lower 0 Vv IMPORTANT NOTE The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications e Only the AstroCap XL and Snorkels are certified for horizontal terminations VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required A vent guard is required when the AstroCap is installed above grade at 7 feet or lower vent guard may also be required in other installations as per local codes refer to Exterior Vent Termination Requirements section for details Note Regen
23. flame control using the remote control Refer to FireWizard operation manual for details d Check for proper flame appearance Installer Notice This instructions must be left with the appliance 23 Locate the control box shown below and remove the 9 jumper using needle nose pliers J9 Jumper Location J9 Jumper 17 Ensure thatthe new rubber gasket supplied with coil is properly positioned and install the new modulating pressure regulator as sembly to the valve using the screws sup plied with the kit Tighten screws securely 18 Install the enclosed identification label to the valve body where it can be easily seen 19 Attach the LP conversion decal near or on top of the serial no decal 20 Replace yellow Natural Gas label with red Propane label 21 Re install the right side panel and all electrical connections to the valve 2 grey wires to modulating coil 22 Remove the left side panel by undoing the 8 screws Regency L900 Direct Vent Gas Fireplace 30 O lt 4 lt U Z Z 2 gt Em gt 4 INSTALLATION LP Conversion instructions for when unit is ALREADY INSTALLED THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION c Place the door on a soft surface to prevent 10 Remove the front burner by removing the LP Conversion Kit Contains scratching screw Qty Part Descripti
24. gt Low Setting Man Pressure 16 WC 0 39 kpa 5 Max Manifold Pressure 35 WC 0 87 kpa Orifice Size Front Burner 47 DMS Orifice Size Back Burner 30 DMS Minimum Input 11 000 Btu h 3 22 KW Maximum Input 48 000 Btu h 14 06 kW PROPANE GAS FIREPLACE MODEL L900 LP Factory Equipped For Altitude 0 4500ft 0 1372m O e Min Supply Pressure 12 WC 2 98 kpa T Low Setting Man Pressure 3 6 WC 0 9 kpa v Max Manifold Pressure 10 WC 2 49 kpa z Orifice Size Front Burner 56 DMS Orifice Size Back Burner 50 DMS 9500 Btu h 2 78 kW 46 500 Btu h 13 62 kW Minimum Input Maximum Input VENTED GAS FIREPLACE HEATER This appliance must be installed in accordance with the manufacturer s installation instructions and with local codes if any if none follow the current ANSI 2223 1 in the USA or the current CAN 1 B149 in Canada This vented gas fireplace heater is not for use with air filters For Manufactured Home Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installation Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance is only for use with the type of gas indicated on the rating plate and may be installe
25. panels should be done by a licensed or qualified service person These components should be replaced immediately Remove the Cap and shine a flashlight down the Vent Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous condensation can cause corrosion of caps pipe and fittings may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Remove the valve tray by following the procedures from Valve Tray Replacement section 2 Disconn
26. seconds after power is applied and will ignore this special command from the Remote after the first 30 seconds NOTE This must only be performed by a quali fied installer Regency L900 Direct Vent Gas Fireplace OPERATING INSTRUCTIONS at lt 3 2 lt Ta TE 9 TI e OFF ON When in Remote position Inthe event of a power failure if the 3 way switch is in the Remote position the unit cannot be operated with the Remote Control until after power is restored To operate unit during a power failure NOTE Both burners when on will operate at the lowest flame setting The BTU s for NG will be 32 000 and 27 000 for LP Front Burner Operation 1 Remove the left side exterior brick panel to access to the Manual Control Panel 2 Toturnon the front burner change the 3 way switch to Manual position Rear Burner Operation 1 Remove the left side exterior brick panel to access to the Manual Control Panel 2 To turn on the rear burner change the Rear Burner Switch to the On position Changing the switch to the Off postion will turn the rear burner off Note The rear burner will only operate if the front burner is on When in Manual position In the event of a power failure if the 3 way switch is in the Manual position the front buner will remain on at the lowest setting and will remain on when power resumes If the rear burner is not in use
27. snow falls and clear to prevent accidental blockage of venting system When using snow blowers make sure snow 5 not directed towards vent termination area Z 9 gt Em gt 4 ASTROCAP XL DIMENSIONS 946 623 P lt 12 1 4 311mm att 12 1 4 311mm 2x4 x6 AstroCap XL Termination Cap gt lt Screws Vinyl Siding Wall Thimble Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws Pull the centre 5 127mm liner and outer 8 203mm liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90 The liners must slip over the collars a minimum of 1 3 8 Apply Mill Pac over the fireplace inner collar and slip the 5 127mm liner down over it and attach with 3 supplied screws Do the same with the 8 203mm liner
28. to operate see Rear Burner Opera tion above Both burners when on will operate at the lowest flame setting The BTU s for NG will be 32 000 and 27 000 for LP When power resumes the unit will remain on at the lowest setting until reset using the remote control NOTE When power is restored reset the 3 way switch on the Manual Control Panel to the Remote position to be able to use the FireWizard Remote Control Burner Tray The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the firebox and body Therefore the varying thicknesses of steel will expand and contract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process OPERATION DURING POWER OUTAGE Important If the unit is not used for a prolonged period of time we recomm
29. to the FireWizard manual for instructions SHUTDOWN PROCEDURE 1 Turn the 3 way switch to the OFF position 2 Turn the main gas control clockwise to the OFF position to turn off the pilot 3 Turn off all electric power to appliance if service is to be performed NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance Listed below are some examples All are normal operating sounds and should notbe considered as defects in your appliance Regency L900 Direct Vent Gas Fireplace 40 O 0 6 OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 Australia AS5601 2004 New Zealand NZS 5261 WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualifie
30. up on a platform to enhance its visual impact The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 3 The L900 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A B C and D See Diagram 1 Regency L900 Direct Vent Gas Fireplace e lt lt ep Z INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Caution Requirements The top back and sides of the fireplace are defined by standoffs The metal ends of the standoff may NOT be recessed into combustible construction Z 9 gt Em gt 4 Clearance to Combustibles from Back 0 Omm Side 0 Omm ED Floor 0 Omm N 6 E Minimum Clearance from Top of Front Facing Mantel min 17 1 2 445mm Ceiling 49 1245mm from top of front facing Side Wall to Unit 16 406mm Horizontal Vent Clearances to Combustibles 65 Top 3 76mm JA Side 2 51mm Bottom 2 51 mm NI N 60 Vertical Vent Clearances to Combustibles All Sides 2 51mm rl U KS
31. 4mm 51mm 33 1 8 838mm 6 Regency L900 Direct Vent Gas Fireplace Z 9 gt JEW gt 4 INSTALLATION 12 Installation and any repairs to this appliance should be done by an authorized service person A professional service person should be called to inspect this appliance annually Make it 3 practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm INSTALLATION CHECKLIST 1 Locate appliance a Room location Refer to Locating Your Gas fireplace section b Clearances to Combustibles Refer to Clearances section c Mantle Clearances Refer to Mantel Clearances section d Framing amp Finishing Requirements Refer to Framing amp Finishing section e Venting Requirements Refer to Venting section 2 Assemble Top Standoffs Refer to Unit Assembly Prior to Installation 3 Install back up batteries Refer to Back up Battery Installation section 4 Convert to propane if desired Refer to Conversion from NG to LP section
32. AGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 a 1 through 4 b EXEMPTIONS The following equipment is exempt from 248 CMR 5 08 2 a 1 through 4 1 The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in the most current edition of NFPA 54 as adopted by the Board and 2 Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling building or structure used in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instructions provided by the manufacturer for installation of the equipme
33. DT 18 2 1 165 5DT 24 SDT 24B SDT 36 5 1 365 5DT 48 5SDT 48B N A N A N A N A SDT AJ 5SDT AJB N A N A N A N A N A N A SDT EL45 5SDT EL45B N A N A SDT EL90S SDT EL90SB N A N A N A N A SDT CS SDT CSS SDT WS B SDT OS SDT WT N A SDT FS SDT TP Simpson Direct Vent GS Discontinued 1208 1208B 1207 1207B 1206 1206B 58DVA 18 58DVA 18B N A from FPI 1204 1204B 1203 1203B 1202 1202B 58DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 1245 1245B 12456 1245BG 58DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A 58DVA 06 58DVA 06B 58DVA 09 58DVA 09B 58DVA 12 58DVA 12B 58DVA 18 58DVA 18B N A from FPI 58DVA 24 58DVA 24B 58DVA 36 58DVA 36B 58DVA 48 58DVA 48B 58DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from FPI 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 58DVA E45 58DVA E45B Disc See 58DVA E45 Disc See 58DVA E45B 58DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A 58DVA DC 58DVA CS 58DVA WS 58DVA ES N A from FPI 58DVA WT 58DVA DC N A from FPI 58DVA FS 58DAV WFS e ae Simpson 6 Pipe Length Galvanized 6
34. IED GAS FITTER IF INDOUBT DO NOT DO THIS CONVERSION b Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up LP Conversion Kit Contains lt 4 lt op Z Qty Part Description 910 462 LP Conversion Coil 904 573 Cable Tie 910 037 LP Pilot Orifice 904 641 Orifice 50 back 904 241 Orifice 56 front Door 904 529 Allen Key 918 590 LP Conversion Decal 908 528 Red Propane Label 918 608 Instruction Sheet es es N Front Burner Removed 1 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox Place the door ona soft surface to prevent scratching 4 Remove the back burner by removing the screw 2 Remove the grate by undoing the 2 screws on the right and left side ana T 5 A a Latch Back Burner 5 Remove the rear log stand by removing the 4 screws Rear Log Stand 3 Remove the front burner by removing the screw Front Burner 28 Regency L900 Direct Vent Gas Fireplace Z 2 gt Em gt 4 INSTALLATION 14 Disconnect the 2 grey connectors from the modulator coil 15 Remove the right side panel by undoing the 9 screws 16 Using a Torx T20 remove and discard the 3 pressure regulator mounting screws Remove the modulator coil and the gasket 10 Re
35. MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram MANTEL LEG Allowable mantel 11 1 2 292mm leg projection Side wall 10 Regency L900 Direct Vent Gas Fireplace INSTALLATION FRAMING amp FINISHING 1 Frame in the enclosure for the unit with framing material The framed Drywall 555 opening for the assembled kit is 50 3 4 high x 52 wide x 26 1 2 On Edge deep 1289mm x H 1321mm W x 673mm D See Diagram 1 Also A 7 gt see Diagram 2 for corner installations VX m gt Header O On 5006 Z 83 2108mm 17 1 2 445mm Min 26 1 2 Non Combustible 673mm Material 1 PaM AI ABF ABE he oe nhl 16 1930mm 62 1321 1 1 Diagram 1 26 1 2 673mm Diagram 3 12 1 4 311mm ao Rs 6 152mm Note When constructing the framed opening please ensure 90 7 16 2286mm there is access to install the gas lines when the unit is installed See diagram 3 for details Diagram 2 2 For exterior walls insulate the enclosure to the same degree as the rest of the house apply vapour barrier and drywall as per local installation codes Do not insulate the fireplace itself Non Combustible Requirements 53 3 4 Stud 3 The unit does not have to be completely enclosed in a chase You 1365mm 0 must maintain clearances from the vent to combustible materials See
36. MODULE DC SPARKER black a NEUTRAL white LIVE black J8 NO JUMPER gt DUAL BURNER WITH JUMPER gt SINGLE BURNER J9 WITH JUMPER gt NG NO JUMPER gt LP SINGLE CONTROL DUAL MODULE A Da vo 5 3 o c 5 hat 2 grey red ees EMBER REAR MANUAL SOLENOID SW SECONDARY MAIN BURNER BURNER LLI Lu 5 5 98 9V SOLENOID h ed o FS VALVE x 528 MODULATING black I COIL H E white MANUAL HT black OFF REMOTE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Regency L900 Direct Vent Gas Fireplace The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude Open the air shutter for a blue flame or close for a more yellow flame In order to adjust the aeration the logs grate and burners will need to be removed to be able to access the shutters A receptacle is provided on the left hand side of the unit 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully The front and rear burners will operate on low when the unit is running on battery back up NEUTRAL white LIVE black Caution Ensure t
37. Mill Pac to the 5 127mm inner collar of the termination and slipping the 5 127mm liner over it at least 1 3 8 35mm Fasten with the 3 screws drilling pilot holes will make this easier Apply Mill Pac or high temperature silicone to the 8 203mm flex pipe and slip it over the 8 outer collar of the vent terminal at least 1 3 8 35mm and fasten with the 3 screws Horizontal sections must be sup ported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner 1 Note 2 3 NOTE Regency L900 Direct Vent Gas Fireplace Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten SIT 825 VALVE DESCRIPTION 1 Gas on off kno
38. T CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE SERIOUS HOUSE FIRE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS AND SHOULD STAY AWAY TOAVOID BURNS OR CLOTHING IGNITION Regency L900 Direct Vent Gas Fireplace INSTALLATION HEAT RELEASE KIT The Heat Release Kit expels warm air from the fireplace to the outside of the building allowing the fireplace to be operated with less heat entering the room The kit may be used on either the left or right side See Heat Release installation manual for complete details and clearances from side only HEARTH REQUIREMENTS Aminimum 33 1 8 838mm wide x 12 305mm deep x 2 51mm thick non combustible hearth is required if the finished floor is not flush with the base of the unit The maximum height between the finished floor and sub floor is 1 25mm Unit Sitting on Sub Floor Non combustible Material Exterior Brick Panel acer Non combustible Material NOTE No hearth is
39. b 2 Electronically Operated Hi Lo 3 Pilot Adjustment 4 Thermocouple Connection option 5 Outlet Pressure Tap 6 Inlet Pressure Tap 7 Pilot Outlet 8 Main Gas Outlet 9 Alternative TC Connection Point TP TH TP IMPORTANT Always check for gas leaks with a soap and water solution or gas leak detector Do not use open flame for leak testing 12 1 4 311mm 6 152mm Opening for Gas Connection PILOT ADJUSTMENT Burner 00 000 00 oo O O O O O O O OO O O O O O Thermopile Thermocouple Pilot Ignitor Periodically check the pilot flames Correct flame pattern has three strong blue flames 1 flowing around the thermopile 1 around the thermocouple and 1 flowing across the burner it does not have to be touching the burner Note Ifyou have anincorrect flame pattern contact your Regency dealer for further instructions Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping from valve at pressures over 1 2 psig The manifold pressure is
40. box Latch b Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up Door nza c Place the door on a soft surface to prevent scratching 2 Unwrap the brick panels from the protective wrapping Note The logs must not be in the unit Regency L900 Direct Vent Gas Fireplace 34 INSTALLATION 5 Install the back brick panel by carefully placing it against the back 7 Slide the left side brick panel into position and secure in place with wall of the firebox the brick panel clip that was removed in step 3 Z 2 gt Em gt 4 Exterior Brick Panel Installation 1 Ensure installation of the logs and glass door has been completed before installing the exterior brick panels 2 Line up the pins in the exterior base brick panel with the holes on the outerbox of the firebox and fit in place 6 Place the top brick panel into position and hold it in place while slid ing the right side brick panel into position and secure using the brick panel clip that was removed in step 3 Outerbox of Firebox 3 Install the right side exterior brick panel by placing the bottom tab into the slot of the exterior base brick panel The top of the brick panel is held in place by a magnet that sits against the bracket as shown in the image below Repeat for left side exterior brick panel Bracket Brick UB Panel Clip
41. caused by environmental or geographical conditions inadequate ventilation excessive offsets negative air pressure caused by mechanical systems such as furnaces fans clothes dryer etc Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer FPI will not be liable for acts of God or acts of terrorism which cause malfunction of the appliance Performance problems due to operator error will not be covered by this warranty policy Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI may nullify your warranty on this product Any alteration to the unit which causes sooting or carboning that results in damage to the interior exterior facia is not the responsibility of FPI Subsidy according to job scale as predetermined by FPI Regency L900 Direct Vent Gas Fireplace 55 FPI fireplaces are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door FPI Fireplace Products International Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product See the inside back cover for details Register your Regency online at http www regency fire com r j G a 1 TI 1 Lj ej a 5 i
42. chusetts only 5 UNIT DIMENSIONS 17111 EINE MISIONS i e 0001010121111 6 INSTALLATION Important Message BEITE YOU SEN Lae 7 General Safety Information 7 Installation Checklist 7 Manufactured Mobile Home Additional Requirements 8 Locating Your Gas Fireplace rrrnrnnnnnrnnnrnnrnnnenrnnnrnnnnn 8 Heatwave Duct Kit se 8 Heat Release Kit 8 Hearth Requirements 8 CIS ARAN CO c 9 Mantel Clearances M K 10 Mantel Leg Clearances 0 00000 10 Framing amp Finishing 11 Unit Assembly Prior To Installation 12 Top Standoff Assembiy 12 Side Nailing Strips EEE 12 Finishing Template 12 Venting 0 00010101 13 Vent Restrictor Position cccseceseeeseeeseeeseeeeseeens 13 Exterior Vent Termination Requirements 06 14 Venting Arrangements E keke 15 Horizontal Termination FIe gt
43. controlled by a regulator built into the gas control and should be checked at the pressure test point INSTALLATION L900 NG SYSTEM DATA 5 WC 1 25 kpa 1 6 WC 0 39 kpa Min Supply Pressure Low Setting Man Pressure Max Manifold Pressure 3 5 WC 0 87 kpa Orifice Size Front 47 DMS Burner Orifice Size Back Burner 30 DMS 11 000 Btu h 3 22 kW Minimum Input 48 000 Btu h 12 3 kW Maximum Input L900 LP SYSTEM DATA 12 WC 2 98 kpa 3 6 WC 2 49 kpa Min Supply Pressure Low Setting Man Pressure Max Manifold Pressure 10 WC 2 98 kpa Orifice Size Front 56 DMS Burner Orifice Size Back Burner 50 DMS 9 500 Btu h 2 64 kW 46 500 Btu h 11 72 kW Minimum Input Maxiumm Input HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CAN1 2 17 M91 GAS LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI 2223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Regency L900 Direct Vent Gas Fireplace 26 INSTALLATION
44. cy Direct Vent System Flex is only approved for horizontal terminations Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet e Firestops are required at each floor level and whenever passing through a wall e A wall thimble is mandatory for all horizontal terminations due to high temperatures Regency L900 Direct Vent Gas Fireplace 19 INSTALLATION Horizontal Venting with Two 2 90 Elbows e lt lt ep Z One 90 elbow Two 45 elbows With these options maximum total pipe length is 30 feet with minimum of 10 feet total vertical and maximum 10 feet total horizontal Please note minimum 1 foot between 90 elbows is required VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required Horizontal Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 10 feet total horizontal VENT RESTRICTOR SETTING Please note min 1 Vent restrictor at 0 factory set no adjustment Kak required 20 Regency L900 Direct Vent Gas Fireplace INSTALLATION Vertical Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows With these options max total pipe length is 30 feet with min o
45. d installer service agency or gas supplier A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 0117972 30 E This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air CAUTION Hot while in operation Do not touch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and other liquids having flammable vap
46. d in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details This appliance is not convertible for use with other gases unless a certified kit is used Kit 546 969 Certified for use with Heat Wave Kit 946 556 and Heat Release Kit 4946 570 For use with glass doors certified with the appliance only Electrical Supply 115 V 0 1 A 60 Hz NOT FOR USE WITH SOLID FUEL Minimum Clearances to Combustibles from Fireplace Side Walls A 16 406mm Ceiling B 49 1245mm Min Mantel Height C 17 1 2 445mm Max Mantel Depth D 13 330mm Alcove Width E 84 Alcove Depth F 36 914mm Non Combustible Hearth Extension Hearth Height G 2 51mm Hearth Width H 33 1 8 841mm Alcove side wall must have a min of 16 406mm clearance on one side Mantel depth taken at 27 1 2 699mm from front facing FPI Fireplace Products International Ltd Delta BC CANADA MADE IN CANADA FABRIQUE AU CANADA 918 609 Regency L900 Direct Vent Gas Fireplace COPY OF SAFETY DECAL SAFETY LABEL This is a copy of the label that accompanies each L900 NG and L900 LP Direct Vent Gas Fireplace We have printed a copy of the contents here for your review The safety label is located on the right hand side of the unit visible when the exterior right side brick panel is removed NOTE Regency units are constantly being improved Check the label on
47. dule 36 Remove the 9 jumper using needle nose pliers J9 Jumper Location 25 Remove the pilot shield by removing the 2 screws 26 Remove the clip from the pilot head assembly using a flat head screw driver Clip 27 Remove the NG pilot orifice with the Allen Key and replace with LP pilot orifice 28 Re install the pilot head and pilot shield 29 Using a Torx T20 remove and discard the 3 pressure regulator mounting screws Remove the modulator coil and the gasket 33 Regency L900 Direct Vent Gas Fireplace INSTALLATION BRICK PANEL INSTALLATION IMPORTANT Must install 1 set of brick panels The operation of this unit without the brick panels is prohibited Dangerous operating conditions may occur if the panels are broken Handle with care DO NOT FORCE INTO POSITION 3 Remove the 2 brick panel clips on the inside left and right side of the firebox by removing the screw 4 Place the 2 small back brick panels at the base of the firebox on the left and right side of the rear log tray Note The left and right side back brick panels are different Left Side Back Brick Panel Right Side Back Brick Panel Right Side Left Side Back Brick Back Brick Panel Panel a Release the 2 door latches on the left and right side at the top of Hinge Interior Brick Panel Installation 1 Remove the glass door lt 4 lt op Z the fire
48. e back standoffs to the inside mounting surface of termination cap For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create 8 level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches Alternate Horizontal Termination Caps Alternate Snorkel Termination Cap Part 1282 14 Part 1281 36 Part 501 5114 14 Part 501 5136 36 The FPI AstroCap XL is certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent GS and Selkirk Direct Temp AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent GS are registered and or proprietary trademarks of Simpson Dura Vent Co Inc Regency L900 Direct Vent Gas Fireplace 16 e lt lt ep Z Z 9 gt EB gt 4 N A N A 5D45L 5D45LB N A N A 5D90L 5D90LB 5D90A SDDA INSTALLATION 5 X 6 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not All Rigid Pipe components are available directly from FPI Metal Fab Sure Seal 5D6 Selkirk Direct Temp SDT 6 SDT 6B SDT 9 5SDT 9B SDT 12 5SDT 12B S
49. ect thermocouple by loosening nut from the valve with a 9mm wrench Disconnect thermopile by loosening 2 screws marked TP on the valve 3 Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple or thermopile with a 7 16 wrench NOTE the pilot line is very fragile use caution when pulling it up 4 Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit 5 Reinstall the new ones in reverse order MAINTENANCE INSTRUCTIONS 1 Always turn offthe gas valve before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3 The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 4 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance
50. end turning the 3 way switch on the manual control panel to Off manual control panel is located on the left hand side of the firebox behind the left side exterior brick panel Also see Lighting Plate Instructions for details on how to turn off the pilot Manual Control Panel 3 way Switch Rear Burner Switch Located on the left hand side of the firebox behind the exterior brick panel NOTE The control knob is located on the right hand side of the firebox behind the right side exterior brick panel 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas 3 Turn knob on gas control counterclockwise to PILOT 4 Push in control knob all the way and hold in until the pilot lights up Continue to hold the control knob in for about 20 seconds after the pilot is lit Release knob and it will pop back up Pilot should remain lit Ifit goes out repeat steps 1 to 4 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 5 Turn gas control knob counterclock wise to 6 Turn the unit on with the remote NOTE When using the remote control refer
51. f 10 feet total vertical and max 8 feet total horizontal Z 9 gt Em gt 4 Please note min 1 foot VENT RESTRICTOR SETTING between 90 elbows is Vent restrictor at 0 factory set no required adjustment required I N Au 0 Regency L900 Direct Vent Gas Fireplace 21 INSTALLATION VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90 elbows with Rigid Pipe Venting Systems for Propane and Natural Gas Two 45 elbows equal to one 90 elbow Maximum of four 45 elbows allowed e lt lt ep Z if E jf Vent Restrictor on Set 3 VL NNN A ve 24 22 a 00 B 20 P OD E N T 2 g1 4 4 k E lJ JU Mi Mi__ MMDMRIMM MM MZ M MTMTZ2Z M2 2_ Z Ra Vent Restrictor on Set 2 0 2 E 16 5 14 12 Ses n SEN N lt 2 XEN N E N 10 Vent Restrictor on Set 1 86 el to PT en EE ra A2 z E 4 2 0 Y e Vent must be supported at offsets e Firestops are required at each floor level and whenever passing through a wall Maintain clearances to comb
52. fting them up q Heat Shield Door 9 Replace the control module 5 Unplug the power source gt gt 10 Reverse steps to re install 6 Cut the cable tie that is holds the wires connected to the control module Control Module Place the door on a soft surface to prevent scratching Regency L900 Direct Vent Gas Fireplace 45 MAINTENANCE DC SPARKER REPLACEMENT 1 Remove the exterior brick panels 4 Lift up and pull out the heat shield slightly 8 Remove the battery cover from the DC to clear the screwheads and then hang it Sparker Box 2 Remove the glass door on the top bracket located directly above the heat shield a Release the 2 door latches on the left and right side at the top of the firebox Bracket Battery Cover Heat Shield Latch 9 Disconnect all the wires and connectors 5 Unplug the power source from the DC sparker 6 Loosen the 2 screws that hold the right side heat shield Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up Heat Shield Door 10 Remove the 2 screws that hold the DC sparker 7 Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield 3 Loosen the 2 screws that hold the left side heat shield in p
53. hat the wires do not touch any hot surfaces and are away from sharp edges 38 Z e lt lt ep Z 0 E Li 27 O Z OPERATING INSTRUCTIONS DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT LIGHTING PROCEDURE IMPORTANT To ignite or reignite the pilot you must first remove the glass door Only when the pilot holds without pressure being applied to the control knob resecure the glass door to the unit The unit must not be operated with the glass door removed IMPORTANT Gas on off knob cannot be turned from PILOT to OFF unless it is partially depressed Ensure that the 3 way switch on the manual control panel is in the Remote position The manual control panel is located on the left hand side of the firebox behind the left side exterior brick panel 3 way Switch 39 OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are n
54. imum of three 3 months coverage from date of replacement FPI venting components are covered parts and subsidized labour for three 3 years from date of purchase Simpson Dura Vent venting components Direct Vent units are covered by Simpson Dura Vent Inc warranty Repair replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No labor coverage is included with these parts Conditions Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of
55. is installed above grade at 7 feet or lower 8 0 WARNING IMPORTANT NOTE The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications Only the AstroCap XL and Snorkels are certified for horizontal terminations Do not combine venting components from different venting systems Use of the the AstroCap XL is acceptable with all systems This product has been evaluated by Intertek for using 8 Rigid Pipe Adaptor in conjunction with Duravent Direct Vent GS and Selkirk Direct Temp systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor Rigid Pipe Vent Systems offer 3 complete line of component parts for installation of both horizontal and vertical installations Many items are offered in decorative black as well as gal vanized finish The minimum components required for 3 basic horizontal termination are AstroCap XL 90 Elbow Rigid Pipe Adaptor Wall Thimble Length of pipe to suit wall thickness _ The minimum components required for a basic vertical termination are 1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar Wall thickness is measured from th
56. ith the Simpson Dura Vent gt is required for all horizontal terminations Direct Vent GS system Install the adaptor 11 after the unit is set in its desired location 9 Slide the appliance and vent assembly Put a bead of high temperature silicone towards the wall carefully inserting the vent inside the outer section of the adapter and Diagram 2 pipe into the vent cap assembly Itis important a bead of Mill Pack on the inner collar Slip that the vent pipe extends into the vent cap the adapter over the existing inner and outer sufficient distance so as to result in a minimum flue collar Fasten to the outer collar only with Note pipe overlap of 1 1 4 inches 32mm Secure the 3 supplied screws drilling pilot holes will a The horizontal run of vent must be level the connection between the vent pipe and make this easier or have a 1 4 inch rise for every 1 foot the vent cap of run towards the termination Never 4 Level the fireplace and fasten it to the framing allow the vent to run downward This 10 Install wall thimble in the center of the 11 using nails or screws through the top and could cause high temperatures and may 279mm square and attach with wood screws side nailing strips present the possibility of a fire Diagram 7 5 Assemble the desired combination of pipe i i and elbows to the appliance adaptor and b The location of the horizontal vent twist lock for a solid connection termination on an exterior wall must meet wood sc
57. l Module 32 546 042 Deflector Log Tray 910 931 Power Module 35 948 459 Burner Rear NG LP 910 930 FireWizard Remote Control 36 948 458 Burner Front NG LP 918 582 Manual FireWizard 37 546 050 Grate 41 502 061 Pilot Shield 42 380 013 Pilot Holder 43 W840470 Gasket Pilot Assembly 46 521 007 Valve Tray 47 546 025 Valve Bracket 48 910 460 Valve NG 825 SIT Electric 910 461 Valve LP 825 SIT Electric 546 574 P Valve Assembly NG 546 576 P Valve Assembly LP 910 008 Pilot Assembly NG 910 009 Pilot Assembly LP 904 617 NG Orifice 30 32 904 622 NG Orifice 47 904 241 LP Orifice 56 904 641 LP Orifice 50 gt 2 3 Op Regency L900 Direct Vent Gas Fireplace 51 NOTES Regency L900 Direct Vent Gas Fireplace 52 NOTES Regency L900 Direct Vent Gas Fireplace 53 NOTES Regency L900 Direct Vent Gas Fireplace 54 WARRANTY FIREPLACE PRODUCTS REGENCY Regency Fireplace Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility FPI Fireplace Products International Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product This warranty is not transferable The Warranty Limited Lifetime The combustion chamber heat exchanger burner tubes pans logs brick panels and gold p
58. lace o 0 lt lt Z LLI lt Heat Shield 11 Replace the DC sparker 12 Reverse steps to re install Heat Shield 46 Regency L900 Direct Vent Gas Fireplace MAINTENANCE 9 Remove the front burner by removing the screw Front Burner Removed 10 Remove the back burner by removing the screw lt gt Z m Z gt Z 2 2 Back Burner 11 Remove the rear log stand by removing the 4 screws Rear Log Stand 3 Loosen the 2 screws that hold the left side heat shield in place Heat Shield Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield JA Bracket Heat Shield Unplug the power source Remove the log set Remove the interior brick panels Remove the grate by undoing the 2 screws on the right and left side VALVE TRAY REPLACEMENT 1 Remove the exterior brick panels 2 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox MM i RD nz Latch Location Latch 4 Swing the door outfrom the top and release the hinges on the left and right side of the door by lifting them up Door 5 6 7 ane 8 c Place the door on asoftsurface to prevent scratching 47 Regency L900 Direct Vent Gas Fireplace MAINTENANCE
59. lating against defective manufacture only are covered under the Limited Lifetime Warranty for five 5 years for parts and subsidized labour and parts only thereafter Glass is covered for lifetime against thermal breakage only parts and subsidized labour for five 5 years and parts only thereafter from date of purchase External casting surrounds and grills are covered against cracks and warps resulting from manufacturer defects parts and subsidized labour for three 3 years from the date of purchase and parts only thereafter Special Finishes One year on brushed nickel and antique copper full screens and doors You can expect some changes in color as the product ages with constant heating and cooling FPI warranties the product for any manufacturing defects on the original product However the manufacturers warranty does not cover changing colors and marks ie finger prints etc applied after the purchase of the product Damage from the use of abrasive cleaners is not covered by warranty Electrical and mechanical components such as blowers switches wiring thermodiscs FPI remote controls spill switches thermopiles thermocouples pilot assembly components and gas valves are covered for two years parts and one year subsidized labour from the date of purchase Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance ie twelve 12 months from original purchase date of appliance with a min
60. length 5 flexible liner Kit length spring spacers 3 thimble 2 AstroCap termination cap 1 946 616 10 Feet screws 12 tube of Mill Pac 1 plated screws 8 5 5 screws 8 x 1 1 2 drill point 4 vinyl siding standoff Vinyl Siding standoff Wall Thimble NN Mandatory in all Horizontal Terminations uard if required art 946 506 P AstroCap XL Termination Cap Part 946 623 P 8 dia Flue pipe gt A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from FPI may be used for Flex installations 3 Horizontal vent must be supported every 3 feet 4 Awallthimble is mandatory for all horizontal terminations due to high temperatures Regency L900 Direct Vent Gas Fireplace 15 INSTALLATION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL amp VERTICAL TERMINATIONS Vertical KO NZ we Storm Collar CD Vinyl Siding Flashing Standoff Optional Ceiling Fres gt AstroCap XL Termination Cap Part 946 623 P Wall Thimble Mandatory in all i Horizontal Terminations Pipe Length Adj Pipe Length 11 14 5 8 90 Elbow ID 24 Pipe Length lt gt Rigid Pipe Adapter l 770 994 A A Vent Guard is required when the AstroCap
61. logy 4 Remove the glass door a Co Axial system The inner liner vents products a Release the 2 door latches on the left of combustion to the outside while the outer and right side at the top of the firebox gt liner draws outside combustion air into the EG combustion chamber thereby eliminating the O 2 Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building Factory Set Vent Restrictor Setting and never be attached to a chimney serving a no adjustment required separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separate vent system Common vent systems are prohibited Latch VENT RESTRICTOR POSITION Vent restriction is required for certain venting installations see the diagrams in the Venting Arrangements section to determine if they are required for your installation Swing the door outfrom the top and release the hinges on the left and right side of the door by lifting them up The Vent Restrictor plate is located on the inside top of the firebox Vent Restrictor Plate Door Vent Restrictor Set 2 2 Remove the screws that hold the vent restric tor plate in place 3 Adjustthe ventrestrictor plate to the required vent restrictor position as per the diagrams shown 4 Once the ventrestrictor plate is in the required posi
62. move the NG pilot orifice with the Allen Key and replace with LP pilot orifice 6 Replace the front burner orifice with orifice 56 See image below Use another wrench to hold onto the elbow behind the orifice 7 Replace the back burner orifice with orifice 50 See image below Use another wrench to hold onto the elbow behind the orifice Rear Burner Orifice Front Burner Orifice 11 Re install the pilot head and pilot shield 12 Loosen the 2 screws that hold the right side heat shield 8 Remove the pilot shield by removing the 2 SCrews Pilot Shield Heat Shield 13 Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield Jr Bracket 9 Remove the clip from the pilot head assembly using a flat head screw driver 5 Heat Shield 29 Regency L900 Direct Vent Gas Fireplace INSTALLATION 24 Re install the left side panel 25 Re install the rear log support bracket 26 Adjust the burner aeration settings to the LP settings and install the burners Front Burner 1 4 Rear Burner 3 8 27 Re install the grate 28 Re install the glass door 29 Re install the right heat shield 30 Continue with completing unit installation NOTE Once the unit has been installed a Turn on the gas supply and check for gas leaks b Check the inlet and outlet pressures c Check operation of
63. ng Arrangemnt Vertical Termination section for the maximum vertical rise of the venting system and Vb the maximum horizontal offset limitations Diagram 1 2 Setthe gas appliance in its desired location Drop a plumb bob down fromthe ceiling to the position of the plumber s appliance flue exit tape andmarkthelocation connected where the vent will to wall strap penetrate the ceiling Drill a small hole at wall his point Next drop Strap a plumb bob from the roof to the hole 4 previously drilled in lt Firestop the ceiling and mark Spacer the spot where the Diagram 2 vent will penetrate the roof Determine if ceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate the appliance or to offset as shown in Diagram 2 to avoid cutting load bearing members 3 AFirestop spacer must be installed in the floor or ceiling of every level firestop spacer 24 e lt lt ep Z INSTALLATION IMPORTANT Do not locate termination hood where excessive snow or ice buildup may occur Be sure to check vent termination area after
64. nt and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system components and 2 A complete parts list for the venting system design or venting system d MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions 6 A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment all venting instructions all parts lists for venting instructions and or all venting design instructions shall remain with the appliance or equipment at the completion of the installation Regency L900 Direct Vent Gas Fireplace 5 UNIT DIMENSIONS e lt lt ep Z 11 279mm 51 1 2 1308mm 5 127mm Inner Dia 8 203mm Outer Dia E vr NEB N 32 1 16 81
65. nt is vertical and secure the base of the flashing to the roof with roofing rails slide storm collar over the pipe section and seal with a mastic 8 Install the vertical termination cap by twist locking it Note Any closets or storage spaces which the vent passes through must be enclosed Offset Chart GS 8 203mm Nominal Diameter ID Offset Pipe Length L Height inches mm inches mm inches 7 N gt l Height Offset Regency L900 Direct Vent Gas Fireplace 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow connections are in the fully twist locked position and sealed Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connec tion Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional Female Locking Z Lugs Mill Pac gt Silicone D Male q Locking Lugs 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles of 1 1 2 38mm Slip the flashing under the shingles shingles should overlap half the flashing as per Diagram
66. ntal vented gas fueled equipment the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back up is installed on the floor level where the gas equipment is to be installed In addition the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGN
67. o gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with the glass removed 5 Verify that the venting and cap are unobstructed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure the paint is properly cured it is recommended you burn your fireplace for at least four 4 hours the first time When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac turing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning NOTE The main burner will always start on HIGH and resume it s last setting after 20 seconds of operation NOTE When the glass is cold and the appliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up MATCHING REMOTE HANDSET amp CONTROL BOX ID CODE The Remote Control Handset has a set of unique ID codes that is pre programmed into its memory This set of ID codes helps to differenti ate one
68. off all electric power to the appliance if service is to be performed You may shut off the pilot during prolonged non use periods to conserve fuel DO NOT REMOVE THIS INSTRUCTION PLATE 218 583 Regency L900 Direct Vent Gas Fireplace 41 MAINTENANCE GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket Part 936 155 DOOR GLASS Your Regency fireplace is supplied with high temperature 5mm Ceramic glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials CAUTION amp WARNINGS Do not clean when the glass is hot The use of substitute glass will void all product warranties Care must be taken to avoid breakage of the glass Do not strike or abuse the glass Do not operate this fireplace without the glass front or with a cracked or broken glass front Wear gloves when removing damaged or broken glass Replacement of the glass panel s should be done by a licensed or qualified service per son GLASS REPLACEMENT Inthe event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped already installed into the door frame CAUTION Wear gloves when removing damaged or broken glass WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass
69. on 4 Loosen the 2 screws that hold the left side 910 462 LP Conversion Coil heat shield in place 904 573 Cable Tie 910 037 LP Pilot Orifice 904 641 Orifice 50 back 904 241 Orifice 56 front 904 529 Allen Key 918 590 LP Conversion Decal 908 528 Red Propane Label 918 608 Instruction Sheet Heat Shield ei es 1 Turn control knob tothe OFF position and shut off the gas supply to the valve 2 Remove exterior brick panels if installed 3 Remove the glass door a Release the 2 door latches on the left and righi side l the t p of the firebox 5 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield 9 8 gi racket Front Burner Removed 11 Remove the back burner by removing the screw Latch Heat Shield 6 Unplug the power source 7 Remove the log set if installed 8 Remove interior brick panels if installed b Swing the door out from the top and l Back Burner release the hinges on the left and right 9 Remove the grate by undoing the 2 screws side of the door by lifting them up on the right and left side 12 Remove the rear log stand by removing the 4 screws Rear Log Stand Door Regency L900 Direct Vent Gas Fireplace 31 INSTALLATION 13 Carefully remove the bottom brick panel Disconnect the 2 connecto
70. ors away Keep burner and control compartment clean See installation and operating instructions accompanying appliance LIGHTING INSTRUCTIONS STOP Read the safety information above on this label 1 Push in gas control knob slightly and turn clockwise TN to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force PILOT BURNER VEILLEUSE j THERMOPILE nl ELEMENT THERMO ELECTRIQUE Gas Inlet 2 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow step B in the Safety Information above on this label If you don t smell gas go to the next step 3 Turn knob on gas control counterclockwise NY to PILOT 4 Push in control knob all the way and hold in until the pilot lights up Continue to hold the control knob in for about 20 seconds after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 1 to 4 If Knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 5 Turn gas control knob counterclock wise to ON 6 Turn the unit on TO TURN OFF GAS APPLIANCE 1 Turn off the unit 2 Push in the gas control knob slightly and turn clockwise to OFF Do not force 3 Turn
71. ovide you with all the warmth and charm of a wood fireplace at the flick of a switch The model L900 has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards VENTED GAS FIREPLACE HEATERS ANSI Z21 88 2005 CSA 2 33 2005 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN CGA 2 17 M91 and ANSI Z21 50b 2003 CSA 2 22b 2003 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI 2223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the cur
72. r source 41 Re install the left heat shield 42 Install the interior brick panels 43 Adjust the burner aeration settings to the LP settings and install the burners 1 4 3 8 Front Burner Rear Burner 44 Re install the grate 45 Turn on the gas supply and check for gas leaks 46 Install the log set 47 Re install the glass door 48 Check the inlet and outlet pressures 49 Re install the right heat shield 50 Check operation of flame control using the remote control Refer to FireWizard operation manual for details 51 Check for proper flame appearance 52 Install the exterior brick panels Installer Notice This instructions must be left with the appliance 30 Ensure that the new rubber gasket supplied with coil is properly positioned and install the new modulating pressure regulator assem bly to the valve using the screws supplied with the kit Tighten screws securely 31 Install the enclosed identification label to the valve body where it can be easily seen 32 Attach the LP conversion decal near or on top of the serial no decal 33 Replace yellow Natural Gas label with red Propane label 34 Re install valve tray and all electrical connections to the valve and solenoid valve 35 Cut the cable tie that holds the wires connected to the Control Module and pull out Note An extra cable tie is included with the LP Kit for re installation Cable Tie Control Mo
73. rent CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 This appliance may only be installed in an aftermarket permanently located manufactured U S A only or mobile home where not prohibited by local codes This appliance can only be used with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Ensure that structural members are not cut or weakened during installation NATIONAL Ve recommend that our products be FIREPLACE INSTITUTE installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI ONE REGENCY ONE TREE For each Regency sold we plant a tree AmericanForests org or in Canada by Wood Energy Technical Wood Energy CERTIFIED Training WETT 2 Regency L900 Direct Vent Gas Fireplace TABLE OF CONTENTS 21 Back Up Battery Installation within Power Module Conversion Kit 546 969 from NG to LP Brick Panel Installation
74. required when the unit is flush with the finished floor as shown below The minimum floor clearance must be maintained from the top surface of the carpet etc to the unit base Unit Sitting on Finished Floor Finished Floor Flat on Wall B Flat on Wall Corner C Recessed into Wall Alcove Corner Diagram 1 4 This appliance is Listed for bedroom installations using the standard FireWizard Remote millivolt thermostat system Some areas may have further requirements check local codes before installation 5 The L900 Direct Vent Gas Fireplace is approved for alcove installations see Clearances section for details 6 We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to Exterior Vent Termination Locations section HEATWAVE DUCT KIT The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home Up to two kits may be installed on the fireplace Please Note Only 1 HeatWave kit may be operated at one time See HeatWave installation manual for complete details and clearances from side only Heat Wave The HeatWave Duct Kit has
75. rews all local and national building codes and Note For best results and optimum must not be blocked or obstructed See gt Diagram 7 NOTE A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower 23 Exterior Vent Termination Locations section for more details performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional N Female 7 Locking CO Lugs Mill Pac J Silicone TN f Male N Locking Diagram 1 Lugs Regency L900 Direct Vent Gas Fireplace INSTALLATION Minimum Vent Height Roof Pitch flat to 7 12 over 7 12 to 8 12 over 8 12 to 9 12 over 9 12 to 10 12 over 10 12 to 11 12 3 25 099 over 11 12 to 12 12 over 12 12 to 14 12 over 14 12 to 16 12 6 163 over 16 12 to 18 12 over 18 12 to 20 12 A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the vent height may solve the problem 7 Ensure ve
76. rs from the 20 Disconnect the black and red wires from modulating coil the solenoid valve 7 5 Bottom Brick Panel lt 4 lt op Z 14 Loosen the 2 screws that hold the right side heat shield 21 Disconnect the 2 red wires and 1 black wire from the valve 18 Remove the DC Sparker wires 1 wire for the ignitor and 2 wires to the module box Modulating Coil Heat Shield 19 Remove the 16 screws that hold the valve tray to the firebox and slightly pull out the valve tray 15 Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield Bracket 22 Completely pull out the valve tray 23 Replace the front burner orifice with orifice 56 See image below Use another wrench to hold onto the elbow behind the orifice 24 Replace the back burner orifice with orifice 50 See image below Use another wrench to hold onto the elbow behind the orifice Heat Shield Front Burner Rear Burner Orifice Orifice 16 Disconnect the inlet gas line from the valve Valve Tray Slightly Removed 32 Regency L900 Direct Vent Gas Fireplace INSTALLATION Z 2 gt Em gt 4 9 Jumper 37 Re install the control module 38 Re install the base brick panel 39 Re install the rear log support bracket 40 Plug in the powe
77. side at the top of the firebox Heat Shield Latch Power Module 9 Replace the 9V battery and the AA battery 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it NOTE The9Vbatteryoperatestherearburner on the top bracket located directly above under power outage conditions the heat shield The AA battery operates the DC Sparker for lighting the pilot Bracket Swing the door outfrom the top and release the hinges on the left and right side of the door by lifting them up Heat Door Shield lt gt Z m Z gt Z 2 Li 10 Reverse steps to re install 5 Unplug the power source 6 Loosen the bottom screw and remove the top screw from the power module c Place the door on a soft surface to prevent scratching Power Module Regency L900 Direct Vent Gas Fireplace 43 MAINTENANCE POWER MODULE REPLACEMENT 8 Remove the 3 connectors from the circuit board 9 Remove the circuit board from the support bracket by turning it around and pushing the plastic pins with a plier 5 a Circuit Board Removed 10 Replace the circuit board 11 Reverse steps to re install 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield nr Bracket J 1 Remove the exterior brick panels 2 Remove the glass door a
78. t Vent Pro ve nek Direct Temp Sure Seal Discontinued Round Support Radiation Sheild N A N A N A N A Flat Flashing N A N A N A N A Attic Insulation Shield 12 58DVA IS N A from FP 58DVA IS N A from FPI Basic Horizontal Termination Kit A N A SDT HKA Horizontal Termination Kit B 58DVA KHA 5DT HKB Vertical Termination Kit 58DVA VCH 5DT VKC e lt lt ep Z High Wind Vertical Cap N A N A High Wind Horizontal Cap DISC N A Horizontal Square Termination Cap N A 5DT HHC Vertical Termination Cap N A 5DT HVC Storm Collar 58DVA SC 5DT SC Adjustable Flashing 0 12 6 12 58DVA F6 1243 5DT AF6 5DE Adjustable Flashing 6 12 12 12 58DVA F12 1243S 5DT AF12 5DF 12 Vinyl Siding Standoff 58DVA VSS 1250 5DT VS 5DVS Vinyl Siding Shield Plate N A N A 5DT VSP N A Snorkel Termination 14 58DVA SNK14 1282 5DT ST14 5DST14 Snorkel Termination 36 N A 1281 5DT ST36 5DST36 Restrictor Disk 58DVA RD N A N A N A Colinear Flex Liner Adapter 3 N A N A N A N A FPI 946 604 P Simpson Direct Vent Vent Guard Optional 946 623 P AstroCap XL Horizontal Cap 770 994 Rigid Pipe Adapter Must use with all Rigid Piping 946 506 P Vent Guard Optional NOTE When using Metal Fab Sure Seal Rigid Piping please note that either the Adaptor 5DDA or 90 Starter Elbow SD90A must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 L676 amp L900 Direct Vent Fireplace IMPORTANT NOTE A Vent
79. terminals shall not be recessed into a wall or siding 7 Any safety glass removed for servicing must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Wearglovesand safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS TheL900 Direct Vent Fireplace must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY PROFESSIONAL SERVICE PERSON MORE FREQUEN
80. the unit and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts For the State of Massachusetts flexible connectors shall not exceed 36 inches in length For the State of Massachusetts the appli ances individual manual shut off must be a t handle type valve The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 anda CO alarm with battery back up in the same room where the gas appliance is installed e lt lt ep Z REQUIREMENTS MA Code CO Detector for the State of Massachusetts only 5 08 Modifications to NFPA 54 Chapter 10 2 Revise 10 8 3 by adding the following additional requirements a For all side wall horizontally vented gas fueled equipment installed in every dwelling building or structure used in whole or in part for residential purposes including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied Z 9 gt JEN gt 4 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizo
81. tion secure with screws i a hi zi Vent Restrictor Set 3 Regency L900 Direct Vent Gas Fireplace 13 INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS e lt lt ep Z Openable YA Vent Termination Air Supply Outlet Area where terminal is not permitted A Clearance above grade veranda porch deck or balcony min 12 30cm B Clearance to window or door that may be opened 12 30cm 9 23cm C Clearance to permanently closed window min 12 30cm D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 60cm from the centerline of the terminal min 33 84cm check with local code E Clearance to unventilated soffit min 33 84cm F Clearance to outside corner with AstroCap Termination Cap min 13 G Clearance to inside corner with AstroCap Termination Cap min 18 H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet min 72 1 8m 3 91cm above if within 10 3m horizontally M Clearance
82. tors from the modulating coil Valve Tray Regency L900 Direct Vent Gas Fireplace 48 y 2 gt JJ 3 Op Op 49 PARTS LIST MAIN ASSEMBLY Description Flue Collar Inner Assembly Flue Collar Outer Capscrew 1 4 x 4 1 2 Gasket Top Relief Plate Top Relief Plate Top Relief Frame Top Relief Frame Gasket Heat Shield ECS Door Frame Assembly with Glass Glass One Piece Faceplate Control Arm Bracket Control Arm Heat Shield Valve Gas Line Screen Plate Brick Panel Set Standard Brown Brick Panel Set Standard Red Left Side Panel Interior Top Panel Interior Back Panel Interior Right Side Panel Interior Right Side Panel Exterior Base Panel Exterior Left Side Panel Exterior Heat Wave Kit Heat Release Kit LP Converison Kit Manual Part 1 521 527 2 502 008 5 904 751 6 W260280 7 770 066F 8 942 117 9 W260260 11 546 064 12 546 540 940 354 P 13 546 013 15 521 021F 16 521 019 17 546 070 18 521 024 20 546 901 546 902 946 556 946 570 546 969 918 610 Not available as a replacement part Regency L900 Direct Vent Gas Fireplace PARTS LIST 00 00 h r a 50 Regency L900 Direct Vent Gas Fireplace PARTS LIST BURNER amp LOG ASSEMBLY Part Description Part Description 910 937 Valve Solenoid 30 521 015 Bracket Log Tray 31 546 016 Log Tray 910 929 Contro
83. unwrap them The logs are fragile handle with care do not force into position 2 Place log 03 41 on the rear log support pins 36 Regency L900 Direct Vent Gas Fireplace INSTALLATION 5 Place the left end of log 03 43 into the pin while fitting the notch 8 Spread all of the Embers on the bottom brick panel around the burner onto the burner tube Slide the right end of the log forward until it is tube and on the inside of the grate as shown approximately 3 8 away from the back side of the grate Z 2 gt Em gt 4 Embers on bottom brick panel Burner Tube 6 Line up the two holes on the underside of log 03 44 with the pins on logs 03 41 and 03 42 and fit in place Embers on inside of grate 9 Spread the vermiculite on the base brick panel covering the remaining exposed base brick 7 Line up the two holes on the underside of log 03 45 with the pins on logs 03 41 and 03 43 and fit in place Regency L900 Direct Vent Gas Fireplace 37 INSTALLATION AERATION ADJUSTMENT Minimum Air Shutter Opening CAUTION Carbon will be produced if air shutter is tightly closed NG Front Burner 1 4 Rear Burner 1 2 Note Any damage due to carboning resulting from improperly setting LP Front Burner 1 4 the aeration controls is NOT covered Rear Burner 3 8 under warranty WIRING DIAGRAM Do not cut the ground terminal off under any circumstances SOLENOID DRIVER POWER
84. ustibles as listed in the Clearances section e Refer to Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required Note Must use optional flue adapter when using Rigid Pipe Part 770 994 22 Regency L900 Direct Vent Gas Fireplace INSTALLATION 7 Ensure that the pipe clearances to combustible materials are maintained Diagram 5 Install the termination cap Horizontal runs of vent must be supported every 3 feet 0 9meter Wall straps are available for this purpose UNIT INSTALLATION WITH HORIZONTAL TERMINATION Note If installing termination on a vinyl 6 Mark the wall for a 11 x 11 279mm x Z 9 gt gt 4 siding covered wall a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding Siding Jn sealant all four sides bolt Horizontal lt Top to Vinyl Standoff lt 279mm square hole The center of the square hole should line up with the center line of the horizontal pipe Cut and frame the 11 inch 279mm square hole in the exterior wall where the vent will be terminated See diagram 2 for center line requirements If the wall being penetrated is constructed of non combustible material i e masonry block or concrete an 8 203mm diameter hole is acceptable Rigid Vent Systems
85. workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this information the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit FPI has no obligation to enhance or modify any unit once manufactured ie as products evolve field modifications or upgrades will not be performed FPI will not be liable for travel costs for service work Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy Embers rockwool gaskets door handles and paint are not covered under the terms of this warranty policy Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy The warranty will not extend to any part which has been tampered with or altered in any way or in our judgment has been subject to misuse improper installation negligence or accident spillage or downdrafts