Home
Quantum Scalar 24 Installation Guide
Contents
1. Scalar 24 cl Installing Removing a RMU The Remote Management Unit RMU allows you to access your Scalar 24 library via a web browser Follow the procedures below to install or remove the RMU For instructions on operating the RMU refer to the Scalar 24 Installation and Operation Guide What s in the Box The following is a list of items that should be included in your RMU kit Description Quantity RMU 1 Installing a Remote Management Unit When installed the library will detect the presence of the RMU However you will need to set the IP Address Subnet Mask and Gateway Address before the RMU will function After you have installed the RMU see the instructions provided in Configuring the RMU on page 3 for information on configuring it Step 1 Remove the RMU from the packaging Step 2 Power down your Scalar 24 and disconnect the AC line cord from the AC source outlet 62 2304 01 WLU NIDNITT TEIN T UTE NE T adic Scalar 24 Step 3 From the rear of the Scalar 24 locate the available RMU slot Loosen the thumbscrew on the cover plate and remove the cover plate Store the cover plate in a convenient place It is required for proper operation and cooling of the library if the RMU is ever removed te Cover Plate Step 5 Plug the power cord into a grounded electrical socket Step 6 Connect the network cable to the RMU Step 7 Power on the Scalar 24 You must configure the RMU before it will funct
2. E Scalar 24 Setting the IP Address You must set the IP Address in the Scalar 24 before you can start the RMU Follow the procedure below to configure your RMU Alternatively you can also configure the RMU through the Setup Wizard A Fd gt NOTE For more information refer to the Scalar 24 Installation and Operation Guide Path Setup Menu User Interface Configures the RMU An error will appear if an RMU is not installed or is not functioning properly Step 1 From the Setup menu highlight and press The current field will be highlighted Make sure you enter a valid number for each field HOE GG GG A Step 2 Setthe IP Address by pressing A and W to change the value of the current field and lt and P to move between fields 4 62 2304 01 RevA Scalar 24 adic The current field will be highlighted Make sure you enter a valid number for each field SUBNET maski jo00 000 000 000 Step 3 Set the Subnet mask by pressing A and W to change the value of the current field and lt and P to move between fields The current field will be highlighted Make Sure you enter a valid number for each field ga Leha 200 280 200 Ae Step 4 Set the Gateway by pressing A and W to change the value of the current field and lt and to move between fields W OGatowayt 200 280 288 2M Step 5 From the last field of the Gateway address press P to set the Gateway mask and highlight Exec
3. ion properly For more information see Configuring the RMU on page 3 2 62 2304 01 RevA Scalar 24 Removing a Remote Management Unit Follow these steps to remove a Remote Management Unit Step 1 Power down the library and host Step 2 On the rear of the library disconnect the AC line cord and SCSI cables from the library Step 3 Disconnect the network cable from the RMU Step 4 Remove the RMU by loosening the thumbscrew and pulling out the RMU Step 5 If you are not replacing this RMU reinstall the cover plate you removed when you initially installed the RMU Configuring the RMU Once the RMU is installed the System Administrator SA must set up the RMU for operation Then you can set the IP Address in the Scalar 24 System Administrator Responsibilities The System Administrator SA must set up the RMU for proper operation The SA responsibilities include establishing a network address for the RMU and establishing the Uniform Resource Locators URL The network address consists of an Internet Protocol IP address subnet mask and gateway IP Address After the network address has been established the SA should test the RMU and URL via a Web browser Once the URL has been verified and accounts have been created the SA can broadcast the URL address to the potential RMU users The SA can delete users and change any user password ADIC 2002 Installing Removing a Remote Management Unit 3 cj
4. ute Wg Press Td Set NET CFG a Complete Step 6 A confirmation screen displays Press 9 to accept the RMU settings Starting the RMU Begin using the RMU by completing the following procedure Your RMU is configured and ready for use Step 1 Open your Web browser ADIC 2002 Installing Removing a Remote Management Unit 5 cj E Scalar 24 Step 2 Point your browser to the RMU IP address excluding any leading zeros For example if your IP address is 182 073 056 052 on the Operator Panel LCD go to the following address http 182 73 56 52 The RMU displays 62 2304 01 RevA
Download Pdf Manuals
Related Search
Related Contents
Cuisinart GR-11 User's Manual Pelco DD5TA User's Manual GLOBAL360をお買い上げいただきまして誠にありがとうございます。本 USER MANUAL - Future Mobility Healthcare Dometic RH 141 D details/user manual - SkillRex Technology ECS5510-48S Management Guide - Edge-Core FX取扱説明書 - ユーレックス Owner`s manual & Installation manual Mode d`emploi et KT715-KT745 Manual del usuario Copyright © All rights reserved.
Failed to retrieve file