Home

Pelco DD5TA User's Manual

image

Contents

1. NON SENSITIVE AREA SENSITIVE AREA 0000000 Figure 2 Backlight 12 Compensation CM9750 Turn the KEY SWITCH to the ON position Press the PROG key PROGRAM appears on the LCD screen Press the PRES key The PRESET prompt appears Enter 95 and press the ENTER key The main menu appears Turn the KEY SWITCH to the OFF position OI GN CM9760 1 Inthe default menu select DEF The Define Submenu appears 2 Enter your four digit PIN 3 Enter 95 and select PRST The main menu appears on the monitor 4 Select the Quit icon to return to the default menu MPT9500 Standard Coaxitron Mode 1 Enter 95 and press the PRESET SET key 2 Position the asterisk in the YES row and press the F1 key The main menu appears Extended Coaxitron or RS 485 Mode 1 Enter 95 and press the PRESET SET key 2 Press the F2 key The main menu appears BACKLIGHT COMPENSATION The two backlight compensation modes are on and off Backlight compensation lets the dome compensate for bright light behind the object you want to view With backlight compensation ON the dome uses only the center 10 percent of the picture for adjusting the iris refer to Figure 2 A bright light source outside this area washes out to white The camera adjusts the iris so the object in the sensitive area is properly exposed To change the backlight compensation mode On the main menu move the joy
2. DD5TA Series Dome Drive Installation Operation Manual C1498M B 7 99 CE ty Pelco 300 W Pontiac Way Clovis e CA 93612 5699 USA Pelco Online http www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 DataFAX 800 289 9108 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 DataFAX 1 559 292 0435 CONTENTS Section Page OPERATION istituti ned ete rti dei vee tb d t o a eet POWER UP DISPLAY eu bo PAN AND TILT FUNCTIONS sssssesseseeeeeneennenetnenne nnn nnnnttnttne teet insit sinn 10 AUTO ELIP e X SCAN SPEED ZOOM iiiseecueieeinesn PROGRAMMING THE SPECTRA LITE sends MAIN MENU ACCESS reete teet ner ihe integras BACKLIGHT COMPENSATION sesenta RESET CAMERA GAIN AGC su SUO ic SHUTTER SPEED krenn tiere tedio tree Pr deren AUTO FOCUS MODE SHARPNESS ss P WHITE BALANDGE 2 ritate ti tert ce atten enestietsnnceuscheewccaveetcaneesdeaa te LINE SYNCHRONIZATION essent nne ennt nnennan POWER UP MODE AUTO FLIP Me b LIMIT STOPS PARK TIME MINUTES iranians treten rer te rete e Eeddup TROUBLESHOOTING eret eter te Eine tet Br dd ee 18 BACK BOX ELECTRONIC ASSEMBLY REMOVAL eee 19 SPECIFIGATIONGS
3. ertt tdi teo tete re CR e Pe ti tended bean 19 REGULATORY NOTICES kisser aeir ivei te e ted ddnde 20 WARRANTY AND RETURN INFORMATION nennen entente 20 LIST OF ILLUSTRATIONS Figure 1 System Components In Ceiling Model Shown 2 s EzTe d To e REDE LIST OF TABLES Table Page A Switch Settings for SW1 oo ec eeceeesceesesseeseeseeeeeeeeeeseeseeesesseseaesateaeeeseaesneeeaees 4 B Switch Settings for SW2 P Type Control see 4 C Switch Settings for SW2 D Type Control 5 Pelco Manual C1498M B 7 99 BACK BOX DOME DRIVE LOWER DOME Figure 1 System Compo IMPORTANT SAFEGUARDS AND WARNINGS Observe the following warnings before installing and using this product T Installation and servicing should only be done by qualified service personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Only use replacement parts Pelco recommends After replacing or repairing this unit s electrical components measure the resistance between the line and exposed parts to verify the exposed parts have not been connected to line circuitry The installation method and materials should be capable of supporting four times the weight of the enclosure pan and tilt camera and lens comb
4. 180 OFF OFF ON OFF ON ON OFF ON 181 ON OFF ON OFF ON ON OFF ON 182 OFF ON ON OFF ON ON OFF ON 183 ON ON ON OFF ON ON OFF ON 184 OFF OFF OFF ON ON ON OFF ON 185 ON OFF OFF ON ON ON OFF ON 186 OFF ON OFF ON ON ON OFF ON 187 ON ON OFF ON ON ON OFF ON 188 OFF OFF ON ON ON ON OFF ON 189 ON OFF ON ON ON ON OFF ON 190 OFF ON ON ON ON ON OFF ON 191 ON ON ON ON ON ON OFF ON 192 OFF OFF OFF OFF OFF OFF ON ON 193 ON OFF OFF OFF OFF OFF ON ON 194 OFF ON OFF OFF OFF OFF ON ON 195 ON ON OFF OFF OFF OFF ON ON 196 OFF OFF ON OFF OFF OFF ON ON 197 ON OFF ON OFF OFF OFF ON ON 198 OFF ON ON OFF OFF OFF ON ON 199 ON ON ON OFF OFF OFF ON ON 200 OFF OFF OFF ON OFF OFF ON ON 201 ON OFF OFF ON OFF OFF ON ON 202 OFF ON OFF ON OFF OFF ON ON 203 ON ON OFF ON OFF OFF ON ON 204 OFF OFF ON ON OFF OFF ON ON 205 ON OFF ON ON OFF OFF ON ON 206 OFF ON ON ON OFF OFF ON ON 207 ON ON ON ON OFF OFF ON ON 208 OFF OFF OFF OFF ON OFF ON ON 209 ON OFF OFF OFF ON OFF ON ON 210 OFF ON OFF OFF ON OFF ON ON 211 ON ON OFF OFF ON OFF ON ON 212 OFF OFF ON OFF ON OFF ON ON 213 ON OFF ON OFF ON OFF ON ON 214 OFF ON ON OFF ON OFF ON ON 215 ON ON ON OFF ON OFF ON ON 216 OFF OFF OFF ON ON OFF ON ON 217 ON OFF OFF ON ON OFF ON ON 218 OFF ON OFF ON ON OFF ON ON 219 ON ON OFF ON ON OFF ON ON 220 OFF OFF ON ON ON OFF ON ON 221 ON OFF ON ON ON OFF ON ON 222 OFF ON ON ON ON OFF ON ON 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON Continued on next page Pelco Manua
5. Gain White balance Auto iris Auto white bal Auto iris mode White bal hue Auto iris level Prev to first camera submenu Next to second camera submenu 2 Line Sync 3 Power Up 4 Other Line sync Power up Auto flip Line sync phase Limit stops Park time minutes Scan speed deg s The following sections explain how to program the Spectra Lite dome using the menu choices MAIN MENU ACCESS You can call up the main menu on your monitor by programming setting or creating preset 95 28 Programming preset 95 for Pelco s controllers varies according to the type of controller you are using Below are instructions for programming preset 95 for various Pelco controllers CM6700 1 Enter the number of the Spectra Lite camera and press the CAM key 2 Enter 95 and hold the PRESET key for two seconds 3 Inthe Edit Preset menu arrow to SET and press the ACK key The main menu appears CM8500 1 Enter the number of the Spectra Lite camera and press the CAM key 2 Highlight PRESET in the Camera menu and hold down the joystick button until the Set Presets prompt appears 3 Enter 95 and press the PRESET key The main menu appears CM9500 Enter the number of the Spectra Lite camera and press the CAM key Press the SELECT key twice Highlight CAM in the Setup menu and press the SELECT key Highlight PRESET in the Camera menu and press the SELECT key Enter 95 and press the F1 key The main menu appears o Rovm 11
6. ON ON OFF ON ON 29 OFF OFF ON ON ON 30 ON OFF ON ON ON 31 OFF ON ON ON ON 32 ON ON ON ON ON 4 Pelco Manual C1498M B 7 99 Table C Switch Settings for SW2 D Type Control NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table B Receiver Address Switch Setting SW2 1 3SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON ON OFF ON OFF OFF OFF 24 OFF OFF OFF ON ON OFF OFF OFF 25 ON OFF OFF ON ON OFF OFF OFF 26 OFF ON OFF ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON
7. Press the Iris Open button to enter the Other submenu Move the joystick up or down to position the cursor beside Limit Stops Press the Iris Open button The cursor moves to the right beside the word On or Off Move the joystick up or down to toggle between On and Off SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting oo0Rom m Programming Limit Stops MANUAL LIMIT STOPS Refer to the documentation for your control system for programming presets then do the following Make sure limit stops are turned ON refer to the Limit Stops section then exit the menu Push the joystick left until you reach the limit you want the camera to go to on the left Program preset 90 23 Push the stick right to the limit you want the camera to go to on the right Program preset 91 24 oU RON Setting presets 90 23 and 91 24 to the same point disables manual limit stops SCAN LIMIT STOPS Refer to the documentation for your control system for programming presets then do the following Make sure limit stops are turned ON refer to the Limit Stops section then exit the menu Push the joystick left until you reach the limit you want the camera to go to on the left Program preset 92 25 Push the joystick right to the limit you want the camera to go to on the right Program preset 93 26 oU RON Setting presets 92 25 and 93 26 to the same p
8. are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringe ment of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages includ ing loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explana tion with the product when returned Pelco 300 West Pontiac Way Clovis CA 93612 5699 Ship freight prepaid to Method of return shipment shall be the same or
9. equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization num ber CA number if returned for credit and RA number if returned for repair Goods returned for repair or credit should be clearly identified with the assigned CA RA number and freight should be prepaid All merchandise returned for credit may be subject to a 2096 restocking and refurbishing charge Pelco 300 West Pontiac Way Clovis CA 93612 5699 Ship freight prepaid to REVISION HISTORY Manual Date Comments C1498M 2 99 Original version 3 99 Removed reference to line synchronization Added material on auto iris Added FCC notice C1498M A 7 99 Revised the preset tilt speed from 100 to 200 degrees second Added model number and specifications for a PAL camera Revised Troubleshooting section Revised manual to new format C1498M B 7 99 Changed camera zoom from 12X to 16X Added line sync and auto focus features Removed auto iris peak and auto sharpness options Replaced R B and M G white balance options with white balance hue option Revised camera specifications Pelco and the Pelco logo are registered trademarks of Pelco 20 Copyright 1999 Pelco All rights reserved Pelco Manual C1498M B 7 99
10. 8M B 7 99 Pelco Manual C1498M B 7 99 To change the mode On the main menu move the joystick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Next Press the Iris Open button to go to the next camera submenu Move the joystick up or down to position the cursor beside Auto Focus Mode Press the Iris Open button The cursor moves to the right beside the word Auto or Off Move the joystick up or down to toggle between Auto and Off SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting ONDARON SHARPNESS To manually adjust the picture sharpness On the main menu move the joystick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Next Press the Iris Open button to go to the next camera submenu Move the joystick up or down to position the cursor beside Sharpness Press the Iris Open button to move the cursor to the right beside the value Move the joystick up or down to a value As you change the value you can see the sharpness change Press the Iris Open button to select the value or press the Iris Close button if you do not want to change the setting op0BRoQw WHITE BALANCE The two white balan
11. F ON OFF 67 ON ON OFF OFF OFF OFF ON OFF 68 OFF OFF ON OFF OFF OFF ON OFF 69 ON OFF ON OFF OFF OFF ON OFF 70 OFF ON ON OFF OFF OFF ON OFF 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON OFF 79 ON ON ON ON OFF OFF ON OFF 80 OFF OFF OFF OFF ON OFF ON OFF 81 ON OFF OFF OFF ON OFF ON OFF 82 OFF ON OFF OFF ON OFF ON OFF 83 ON ON OFF OFF ON OFF ON OFF 84 OFF OFF ON OFF ON OFF ON OFF 85 ON OFF ON OFF ON OFF ON OFF 86 OFF ON ON OFF ON OFF ON OFF 87 ON ON ON OFF ON OFF ON OFF 88 OFF OFF OFF ON ON OFF ON OFF 89 ON OFF OFF ON ON OFF ON OFF 90 OFF ON OFF ON ON OFF ON OFF 91 ON ON OFF ON ON OFF ON OFF 92 OFF OFF ON ON ON OFF ON OFF 93 ON OFF ON ON ON OFF ON OFF 94 OFF ON ON ON ON OFF ON OFF 95 ON ON ON ON ON OFF ON OFF 96 OFF OFF OFF OFF OFF ON ON OFF 97 ON OFF OFF OFF OFF ON ON OFF 98 OFF ON OFF OFF OFF ON ON OFF 99 ON ON OFF OFF OFF ON ON OFF 100 OFF OFF ON OFF OFF ON ON OFF 101 ON OFF ON OFF OFF ON ON OFF 102 OFF ON ON OFF OFF ON ON OFF 103 ON ON ON OFF OFF ON ON OFF 104 OFF OFF OFF ON OFF ON ON OFF 105 ON OFF OFF ON OFF ON ON OFF 106 OFF ON OFF ON OFF ON ON OFF 107 ON ON OFF ON OFF ON ON OFF 108 OFF OFF ON ON OFF ON ON OFF 109 ON OFF ON ON OFF ON ON OFF 110 OFF ON ON ON OFF ON ON OFF 111 ON ON ON ON OFF ON ON OFF 112 OFF OFF OFF OFF ON ON ON
12. FF ON OFF OFF ON 147 ON ON OFF OFF ON OFF OFF ON 148 OFF OFF ON OFF ON OFF OFF ON 149 ON OFF ON OFF ON OFF OFF ON 150 OFF ON ON OFF ON OFF OFF ON 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 159 ON ON ON ON ON OFF OFF ON 160 OFF OFF OFF OFF OFF ON OFF ON 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON ON OFF OFF ON OFF ON 167 ON ON ON OFF OFF ON OFF ON 168 OFF OFF OFF ON OFF ON OFF ON Continued on next page Pelco Manual C1498M B 7 99 Table C Switch Settings for SW2 D Type Control Continued NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table B Receiver Address Switch Setting SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 169 ON OFF OFF ON OFF ON OFF ON 170 OFF ON OFF ON OFF ON OFF ON 171 ON ON OFF ON OFF ON OFF ON 172 OFF OFF ON ON OFF ON OFF ON 173 ON OFF ON ON OFF ON OFF ON 174 OFF ON ON ON OFF ON OFF ON 175 ON ON ON ON OFF ON OFF ON 176 OFF OFF OFF OFF ON ON OFF ON 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OFF ON ON OFF ON
13. OFF Continued on next page Pelco Manual C1498M B 7 99 Table C Switch Settings for SW2 D Type Control Continued NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table B Receiver Address Switch Setting SW2 1 SW2 2 3SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 113 ON OFF OFF OFF ON ON ON OFF 114 OFF ON OFF OFF ON ON ON OFF 115 ON ON OFF OFF ON ON ON OFF 116 OFF OFF ON OFF ON ON ON OFF 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON ON OFF 121 ON OFF OFF ON ON ON ON OFF 122 OFF ON OFF ON ON ON ON OFF 123 ON ON OFF ON ON ON ON OFF 124 OFF OFF ON ON ON ON ON OFF 125 ON OFF ON ON ON ON ON OFF 126 OFF ON ON ON ON ON ON OFF 127 ON ON ON ON ON ON ON OFF 128 OFF OFF OFF OFF OFF OFF OFF ON 129 ON OFF OFF OFF OFF OFF OFF ON 130 OFF ON OFF OFF OFF OFF OFF ON 131 ON ON OFF OFF OFF OFF OFF ON 132 OFF OFF ON OFF OFF OFF OFF ON 133 ON OFF ON OFF OFF OFF OFF ON 134 OFF ON ON OFF OFF OFF OFF ON 135 ON ON ON OFF OFF OFF OFF ON 136 OFF OFF OFF ON OFF OFF OFF ON 137 ON OFF OFF ON OFF OFF OFF ON 138 OFF ON OFF ON OFF OFF OFF ON 139 ON ON OFF ON OFF OFF OFF ON 140 OFF OFF ON ON OFF OFF OFF ON 141 ON OFF ON ON OFF OFF OFF ON 142 OFF ON ON ON OFF OFF OFF ON 143 ON ON ON ON OFF OFF OFF ON 144 OFF OFF OFF OFF ON OFF OFF ON 145 ON OFF OFF OFF ON OFF OFF ON 146 OFF ON OFF O
14. OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON ON OFF OFF ON OFF OFF 39 ON ON ON OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF OFF Pelco Manual C1498M B 7 99 Continued on next page Table C Switch Settings for SW2 D Type Control Continued NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table B Receiver Address Switch Setting SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF OFF 64 OFF OFF OFF OFF OFF OFF ON OFF 65 ON OFF OFF OFF OFF OFF ON OFF 66 OFF ON OFF OFF OFF OF
15. Spectra Lite model DD5TAC PAL Spectra Lite model DD5TAC X Scanning System 2 1 interlace Image Sensor 1 4 inch interline transfer Effective Pixels NTSC 510 H x 492 V PAL 500 H x 582 V Resolution NTSC 350 TV lines PAL 350 TV lines Lens Minimum f stop F 1 6 Focal Length 3 9 mm to 63 mm optical Zoom Ratio 16X optical zoom Horizontal Angle of View 44 at 3 9 mm wide zoom 3 at 63 mm telephoto zoom MTBF gt 1 million cycles at room temperature zoom focus iris Focus Automatic with manual override and preset capability 19 Sensitivity 1 lux at f1 6 at signal level of 40 IRE gain high AGC on Signal Process DSP 3R Sync System AC line lock White Balance Automatic with manual override Shutter Speed Automatic electronic iris manual NTSC 1 60 1 10 000 PAL 1 50 1 10 000 Iris Control Automatic with manual override Gain Control Automatic with manual override Video Output 714 V 07 V 100 IRE 10 IRE Signal to Noise gt 46 dB Manual control over camera setup functions depends on the head end and is not available on all control models Design and product specifications subject to change without notice REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reason able protection against harmful interference when the equipment is operated in a co
16. ation it will not change any other camera parameters such as auto focus or auto iris Press the Iris Close button if you do not want to change the setting POWER UP MODE This feature lets the dome resume a desired condition following power up The menu includes the following choices Default On power up the dome goes through a configuration cycle and stops at zero reference showing Configuration Done address and mode settings on the screen Park The dome moves to preset 1 when the power up sequence finishes The only text on the screen is the preset label if any Scan Auto The dome initiates scan mode when the power up sequence finishes Again there is no text Scan Frame The dome initiates a frame scan when the power up sequence finishes Scan Rand The dome initiates a random scan when the power up sequence finishes The default setting is Default To select the power up mode 1 On the main menu move the joystick up or down to position the cursor gt beside Power Up Mode 2 Press the Iris Open button to enter the Power Up Mode submenu 3 Press the Iris Open button to move the cursor to the right 4 Move the joystick up or down to cycle through the selections Stop on the item you want to select 5 SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting AUTO FLIP The two auto flip modes are on auto flip enab
17. ce settings are auto and white balance hue To change the white balance setting 1 On the main menu move the joystick up or down to position the cursor gt beside Camera 2 Press the Iris Open button to enter the Camera submenu 3 Move the joystick up or down to position the cursor beside Next 4 Pressthe lris Open button to go to the next camera submenu 5 Move the joystick up or down to position the cursor beside White Balance 6 Press the Iris Open button Another menu appears with the auto and white balance hue selections 7 Move the joystick up or down to position the cursor beside one of the choices Press the Iris Open button AUTO WHITE BALANCE Move the joystick up or down to toggle between the Auto and Off choices Press the Iris Open button to select one or press the Iris Close button if you do not want to change the setting WHITE BALANCE HUE Adjust the color by moving the joystick up or down to a value between 1 blue end of the spectrum and 99 red end Hold the joystick up or down to fast forward or fast reverse through the values As you change the value you can see the color change on your monitor Press the Iris Open button to select the value or press the lris Close button if you do not want to change the setting If Auto White Balance is on it changes to off when you select a new value LINE SYNCHRONIZATION You can turn line synchronization on or off If itis on you can adjust the synchronizatio
18. change the gain 1 On the main menu move the joystick up or down to position the cursor gt beside Camera 2 Press the Iris Open button to enter the Camera submenu 3 Move the joystick up or down to position the cursor beside Gain AGC 4 Pressthe lris Open button to enter the Gain AGC submenu 5 Move the joystick up or down to position the cursor beside Gain 6 Press the Iris Open button The cursor moves to the right beside the current gain Setting a numeric value 7 Move the joystick up or down to change the gain making the picture on your monitor get brighter or darker 8 SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting AUTO IRIS There are two settings for auto iris mode and level To change the settings for auto iris 1 Program preset 95 28 if in 32 preset mode refer to the Preset Functions section to access the main menu refer to the Main Menu Access section The main menu will appear If the cursor gt is not beside Camera move the joystick up or down to position the cursor beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Auto lris Press the Iris Open button Another menu will appear with auto iris mode and level Selections 13 6 Move the joystick up or down to position the cursor beside one of the choices Press th
19. controllers or with American Dynamics control systems using the AD2083 Translator P type control is RS 422 that is compatible with Pelco s CM6700 CM9750 CM9760 control systems OFF Use with controllers that have more than 32 presets ON Use with American Dynamics controllers 32 presets OFF Use with all control systems except CM9502 with variable speed keyboards For CM9502 with fixed speed keyboards set switch OFF ON Use with CM9502 with variable speed keyboards for smoother joystick control Table B Switch Settings for SW2 P Type Control NOTE For Coaxitron controls SW2 is not used set all switches OFF For D type control systems refer to Table C Baud Switch Setting Receiver Address Switch Setting Rate SW2 6 SW2 7 SW2 8 SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 2400 OFF OFF OFF 1 OFF OFF OFF OFF OFF 4800 ON OFF OFF 2 ON OFF OFF OFF OFF 9600 OFF ON OFF 3 OFF ON OFF OFF OFF 4 ON ON OFF OFF OFF 5 OFF OFF ON OFF OFF 6 ON OFF ON OFF OFF 7 OFF ON ON OFF OFF 8 ON ON ON OFF OFF 9 OFF OFF OFF ON OFF 10 ON OFF OFF ON OFF 11 OFF ON OFF ON OFF 12 ON ON OFF ON OFF 13 OFF OFF ON ON OFF 14 ON OFF ON ON OFF 15 OFF ON ON ON OFF 16 ON ON ON ON OFF 17 OFF OFF OFF OFF ON 18 ON OFF OFF OFF ON 19 OFF ON OFF OFF ON 20 ON ON OFF OFF ON 21 OFF OFF ON OFF ON 22 ON OFF ON OFF ON 23 OFF ON ON OFF ON 24 ON ON ON OFF ON 25 OFF OFF OFF ON ON 26 ON OFF OFF ON ON 27 OFF ON OFF ON ON 28
20. cs controller use the number in parentheses RANDOM FRAME AND AUTO SCANNING Program preset 97 30 to start random scanning Program preset 98 31 to activate frame scanning three seconds of scanning followed by a three second pause Program preset 99 32 to start auto continuous scanning 10 Pelco Manual C1498M B 7 99 PARK Software controls scan limit stops When the dome reaches one it immediately reverses direction Refer to the Limit Stops section to program the scan limit stops Program preset 96 29 to stop a scan Any pan and tilt or lens command also stops a scan If the dome does not receive any commands for a specified period it goes to preset 1 and parks The dome will not park if the time specified is zero or preset 1 has not been programmed The default is zero minutes PROGRAMMING THE SPECTRA LITE Pelco Manual C1498M B 7 99 The dome can be programmed for the following functions AGC automatic gain control Camera reset Scan speed Auto flip disable Gain Sharpness Auto focus Limit stops Shutter speed Auto park time Power line synchronization White balance Backlight compensation Power up mode The main menu contains four secondary menus Camera Line Sync Power Up and Other Each secondary menu has submenus which are structured as follows 1 Camera First Camera Submenu Second Camera Submenu Backlight comp Shutter speed Reset camera Auto focus mode Gain AGC Sharpness AGC mode Sharpness
21. e Iris Open button MODE The cursor moves to one of two choices Auto or Off In the Auto mode the iris is automatically adjusted to produce a constant video output as determined by the Level setting below In the Off mode auto iris is disabled and control is always manual Move the joystick up or down to toggle between Auto and Off Press the Iris Open button to select the choice or press the Iris Close button if you do not want to change the setting LEVEL The cursor moves to a numeric value which the Spectra Lite dome uses to try to maintain a certain light level Changing the value of the Level setting will change the video level to which the auto iris adjusts This setting should be adjusted if the video level in the auto iris mode is too bright or too dark Move the joystick up or down to a value If auto iris is in the auto mode it remains that way until you manually open or close the iris The dome will return to auto iris when it is panned or tilted more than 15 degrees If there is not enough light for a good picture when the iris is wide open you can increase the gain of the camera to improve the picture To do this 1 Hold down the Iris Open button until the iris is wide open 2 Release the button 3 Within one second hold down the button again This will start increasing the camera gain Hold down the button until you get a desirable picture or reach the maximum gain SHUTTER SPEED There are seven electronic sh
22. e dome drive to the factory Also return the back box electronic assembly Refer to the Back Box Electronic Assembly Removal section If you substituted a dome drive turn on power If the unit operates the original dome drive is bad Return it to the factory If the unit still does not operate then the interconnect board is bad Return the back box electronic assembly to the factory Refer to the Back Box Electronic Assembly Removal section BACK BOX ELECTRONIC ASSEMBLY REMOVAL 1 Turn off power 2 Open the interconnect door and disconnect all wiring to the back box 3 Use an 11 32 socket driver to remove the three 8 32 washers and nuts that hold the electronic assembly to the back box When you remove the screws the interconnect back box receptacle will drop down You may have to move the open interconnect door past 90 degrees vertical toward the side of the back box to release the door from the built in grounding strip and free the interconnect back box receptacle 4 Remove the interconnect back box receptacle with the electronic components from the back box SPECIFICATIONS MECHANICAL Pan Movement 360 continuous pan rotation Vertical Tilt Unobstructed 2 to 92 Manual Pan Speed 0 5 80 sec manual operation 150 sec turbo Manual Tilt Speed 0 5 40 sec Preset Speeds Pan 250 sec Pelco Manual C1498M B 7 99 Tilt 200 sec Fixed Speed Controller Pan 30 sec Tilt 12 sec CAMERA Signal Format NTSC
23. er heater elements in the back box turn on at 70 F 21 C and off at 85 F 29 C The heater element in the lower dome turns on at 40 F 4 C and off at 60 F 16 C The interconnect door fan and heater fans in the outdoor back box operate continuously POWER UP DISPLAY NOTE The dome will stop operating if voltage at the dome drops below 18 VAC It will turn back on and go through its start up routine when the voltage exceeds 18 VAC Pelco Manual C1498M B 7 99 When the dome is powered up or reset the monitor displays the selected protocol revision number and other information which remains until the dome moves The information displayed depends on the selected protocol and the choice made on the menu for selectable power up mode As a default the dome goes to a random position The control system protocol C D or P appears C is for Pelco s Coaxitron control system D type control is RS 422 compatible with Pelco s CM6700 MPT9500 and CM8500 controllers or with American Dynamics control systems using the AD2083 Translator P type control is RS 422 compatible with Pelco s CM6700 and CM9750 CM9760 control systems For D and P protocols the device address baud rate parity N number of data bits 8 and number of stop bits 1 appears For D protocol 32 presets appears if the 32 preset mode is selected SW1 7 ON CM9500 mode appears if CM9500 mode is selected SW1 8 ON PAN AND TILT FUNCTIONS Use your cont
24. ination The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION This symbol indicates that there are RISK OF ELECTRIC SHOCK important operating and maintenance DO NOT OPEN instructions in the literature accompany ing this unit Please thoroughly familiarize yourself with the information in this manual prior to installation and operation DESCRIPTION Dome drives in the DD5TA Series are part of the Spectra Lite dome system refer to Figure 1 The dome drives can do the following 360 pan rotation preset positioning 2 to 92 tilt variable speed All dome drives include a color CCD camera with a 16X zoom lens and capability to focus when going to a preset position An integral receiver has a switch to select the type of control The receiver supports Coaxitron and RS 422 control types The dome operates on 24 VAC The dome drive is quickly installed and removed from the back box without tools MODELS DD5TAC Dome drive with color camera and lens NTSC standard FCC UL cUL nents In Ceiling DD5TAC X Dome drive with color camera and lens PAL standard CE Model Shown INSTALLATION if Pelco Manual C1498M B 7 99 Turn on power to the back box The red LED should light to indicate power If the LED does not light correct the trouble before proceeding Refer to the Troubleshoot
25. ing section of the SD5 Series Spectra II and Spectra Lite Dome Installation Operation manual If the light operates you may either leave power on or turn it off before continuing the installation 2 Set the switches on the bottom of the dome drive Refer to Table A for the settings for SW1 and Table B and Table C for SW2 CAUTION Make 3 Install the dome drive in the back box Line up the green tab and red tab on the dome sure the dome drive with the green label and red label on the back box Raise the dome drive into the drive locks into back box and push on the ends of the tabs until they both click into place on the back box place Pull down on the dome drive with moderate pressure to ensure that it stays in place 4 Turn on power if it is not on Listen for the fan operating If the fan does not work the dome will overheat and shut down If the fan does not work return the back box electronic assembly and dome drive to the factory for repair Refer to the Back Box Electronic Assembly Removal section in manual C1487M C Table A Switch Settings for SW1 Control Type Switch Setting SW1 1 SWi1 2 SWi1 3 SW1 4 SW1 5 SW1 6 SW1 7 SWh1 8 Coaxitron OFF OFF OFF OFF OFF OFF OFF OFF P Type Control ON OFF OFF OFF OFF OFF OFF OFF D Type Control OFF ON OFF OFF OFF OFF OFF OFF NOTES Switches SW1 3 through SW1 6 MUST be OFF D type control is RS 422 that is compatible with Pelco s CM6700 MPT9500 and CM8500
26. l C1498M B 7 99 Table C Switch Settings for SW2 D Type Control Continued NOTE For Coaxitron controls SW2 is not used set all switches OFF For P type control systems refer to Table B Receiver Address Switch Setting SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 SW2 8 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON ON ON 235 ON ON OFF ON OFF ON ON ON 236 OFF OFF ON ON OFF ON ON ON 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF ON ON ON ON 243 ON ON OFF OFF ON ON ON ON 244 OFF OFF ON OFF ON ON ON ON 245 ON OFF ON OFF ON ON ON ON 246 OFF ON ON OFF ON ON ON ON 247 ON ON ON OFF ON ON ON ON 248 OFF OFF OFF ON ON ON ON ON 249 ON OFF OFF ON ON ON ON ON 250 OFF ON OFF ON ON ON ON ON 251 ON ON OFF ON ON ON ON ON 252 OFF OFF ON ON ON ON ON ON 253 ON OFF ON ON ON ON ON ON 254 OFF ON ON ON ON ON ON ON OPERATION The red LED in the back box interconnect door lights when power is turned on and the fan exhausts heat from inside the back box when the dome drive is installed If you have an outdoor pendant model with a heat
27. led or off feature disabled To change the auto flip mode On the main menu move the joystick up or down to position the cursor gt beside Other Press the Iris Open button to enter the Other submenu Move the joystick up or down to position the cursor beside Auto Flip Press the Iris Open button The cursor moves to the right beside the word On or Off Move the joystick up or down to toggle between On and Off SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting DRN Pelco Manual C1498M B 7 99 NOTE Programming preset 90 23 disables the manual limit stops until preset 91 24 is set NOTE On power up the auto scan tilt angle will be whatever angle the camera was at when the right scan limit was set NOTE Preset 1 must be programmed for the dome to park Pelco Manual C1498M B 7 99 LIMIT STOPS The two types of limit stop are manual and scan When manual limit stops are set a manual joystick pan operation stops when a limit is reached When scan limit stops are set the dome reverses direction during random frame and auto scanning when a limit stop is reached Software controls limit stops To set limit stops 1 Turn on limit stop mode 2 Program the limit stops Turning Limit Stops On or Off To change the limit stop mode On the main menu move the joystick up or down to position the cursor gt beside Other
28. mmer cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Three years on Genex Series multiplexers server and keyboard Two years on all standard motorized and fixed focal length lenses Two years on Esprit Legacy Intercept PV1000 Series CM6700 CM8500 CM9500 CM9750 CM9760 Matrix Spectra DF5 Series and DF8 Fixed Dome products Two years on WW5700 series window wiper excluding wiper blades Two years on cameras Six months on all pan and tilts scanners or preset lenses used in continu ous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse al teration normal wear or accident
29. n button to reset the camera Pelco Manual C1498M B 7 99 Pelco Manual C1498M B 7 99 GAIN AGC AGC Mode The two AGC Automatic Gain Control modes are auto and off In auto mode the dome automatically adjusts the gain the amount of amplification the camera places on its video information to obtain a full 1 volt peak to peak video signal out If the iris is manually opened to its wide open position and the picture is weak the AGC can be turned off and the gain increased manually to improve the picture When you close the iris the AGC turns back on automatically when the lens iris starts closing In off mode the AGC is off To change the AGC mode Qo UO Ore couv On the main menu move the joystick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Gain AGC Press the Iris Open button to enter the Gain AGC submenu Move the joystick up or down to position the cursor beside AGC mode Press the Iris Open button The cursor moves to the right beside the word Auto or Off Move the joystick up or down to choose between Auto or Off SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting Gain Gain adjusts the signal level of the video output Increasing the gain in low light conditions increases the noise level in the picture To
30. n of the power line voltage so it is in phase with other cameras If cameras are out of phase with each other they may produce what appears to be vertical roll when switching between cameras If it is off the dome synchronizes to an internal clock 15 16 To change the line synchronization settings 1 On the main menu move the joystick up or down to position the cursor gt beside Line Sync 2 Press the Iris Open button Another menu appears with the Line Sync and Line Sync Phase selections 3 Move the joystick up or down to position the cursor beside one of the choices LINE SYNC Move the joystick up or down to toggle between On and Off Press the lris Open button to select the choice If you changed to Off the camera may reset itself as it adjusts to the new synchronization If the camera resets it only affects line synchroniza tion it will not change any other camera parameters such as auto focus or auto iris Press the Iris Close button if you do not want to change the setting LINE SYNC PHASE Move the joystick up or down to change the numeric value The value represents the phase angle in tenths of a degree between 0 and 350 degrees for example 900 is 90 degrees 2400 is 240 Press the Iris Open button to select your choice The Line Sync setting will change to On The camera may reset or the picture on your monitor may wiggle when you change the phase angle If the camera resets it only affects line synchroniz
31. oint disables scan limit stops PARK TIME MINUTES This feature parks the dome at preset 1 after a programmed number of minutes of control inactivity You can set the time from 1 to 720 minutes 12 hours Setting the time to zero disables this feature To change the park time On the main menu move the joystick up or down to position the cursor gt beside Other Press the Iris Open button to enter the Other submenu Move the joystick up or down to position the cursor beside Park Time Minutes Press the Iris Open button The cursor moves to the right beside the current park time Move the joystick up or down to change the park time SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting SCAN SPEED Scan speed is adjustable from 1 40 degrees per second and occurs in three scan modes auto random and frame To change the scan speed oo0RoOom 1 On the main menu move the joystick up or down to position the cursor gt beside Other 2 Press the Iris Open button to enter the Other submenu 17 Move the joystick up or down to position the cursor beside Scan Speed deg s Press the Iris Open button The cursor moves to the right beside the current number of degrees Move the joystick up or down to toggle through the number of degrees 1 40 until you reach the number you want If set on a low number the scan will appear to barely move but i
32. pair Refer to the Back Box Electronic Assembly Removal section Turn on power If the red power LED on the door of the interconnect circuit board in the back box does not light turn off power a Open the door to the interconnect circuit board and check the fuse located next to the fan If bad replace it Pelco part number FUS1 6 5X20FAST This is a 1 6 ampere fuse 5 x 20 mm fast blow b If the fuse is good turn on power and use a voltmeter to check if 24 VAC is getting to the power connector on the interconnect circuit board located next to the fuse c If there is 24 VAC to the power connector turn off power and return the back box electronic assembly to the factory for repair Refer to the Back Box Electronic Assembly Removal section d If there is no voltage at the power connector check your power supply Pelco Manual C1498M B 7 99 8 Ifthe red power LED is lit turn off power a Open the door to the interconnect circuit board and check that all connectors are fully seated Make sure the wiring is correct between the unit and controller Close the door Check the switch settings on the dome drive refer to Tables A B and C and reinstall the dome drive Turn on power If the unit still does not operate turn off power and replace the dome drive with a unit that is good if you have a spare Check the switch settings on the substitute dome drive before installing it If you do not have a spare return th
33. roller s joystick to control pan and tilt operation Fixed Speed Controllers Pan and tilt operation is at a fixed speed the controller determines the speed Variable Speed Controllers Depending on the joystick s position standard pan operation ranges from 0 5 to 80 degrees per second dps standard tilt operation ranges from 0 5 to 40 dps When performing preset operations pan speed is 250 dps tilt speed is 200 dps In turbo mode pan speed is 150 dps while turbo mode does not affect tilt speed AUTO FLIP When the camera tilts down and just beyond vertical the dome rotates 180 degrees When the dome rotates flips the camera starts moving upward while you continue holding the joystick in the down position Once you release the joystick after the dome rotates joystick control returns to normal operation Auto flip is useful for following someone who passes directly beneath the camera You can disable this feature in the auto flip programming menu SCAN SPEED Scan speed is adjustable from 1 to 40 degrees per second through the programming menu ZOOM The Spectra Lite dome can magnify an object up to 16 times 16X of optical zoom Zoom Telephoto Press and hold down the Zoom Tele button or turn the joystick clockwise until you have the picture you want Zoom Wide Press the Zoom Wide button or turn the joystick counterclockwise to increase the field of view PRESET FUNCTIONS NOTE For American The Spectra Li
34. s still functioning SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting TROUBLESHOOTING NOTE The dome drive con Symptom Unit or fan does not operate tains no user serviceable parts If there is a problem 1 with the dome drive return it to Pelco as a complete unit 2 for servicing 18 Make sure your controller is trying to communicate with the unit and not another camera Turn off power Remove the lower dome In Ceiling Models Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver to pop loose the trim ring and lower dome Pendant Models Remove the two screws that hold the trim ring to the back box Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver to free the lower dome from the back box Remove the dome drive Push in on the green drive eject tab on the side of the dome drive and gently rock the dome drive to release the latch When the green latch releases pull the dome down Do one of the following If your problem was that the unit would not operate Proceed to step 6 If your problem was that the fan would not operate Make sure the connector for the fan is fully seated Replace the dome drive Turn on power If the fan does not operate return the back box electronic assembly and dome drive to the factory for re
35. stick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Backlight Comp Press the Iris Open button The cursor moves to the right beside the word On or Off Move the joystick up or down to toggle between On and Off SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting RESET CAMERA Resetting the camera returns the following settings to their defaults OY Qr R O Setting Default Auto focus mode Auto Gain AGC AGC mode Auto Gain No default setting Backlight comp Off Auto iris Mode Auto Level Default value depends on type of camera Shutter speed Auto White balance Auto white balance White balance hue Sharpness Sharpness On No default setting No default setting The following settings are not reset when the camera is reset park time auto flip disable and limit stops Turning off power to the dome does not reset the camera Camera settings are retained in memory and when power is restored the settings are the same as when the camera was turned off To reset the camera Bom On the main menu move the joystick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Reset Camera Press the Iris Ope
36. te dome can go to 32 preset locations each with a 20 character label Dynamics controllers with Presets are numbered 1 32 Refer to your control system documentation for programming only 32 presets set switch presets SW1 7 on the dome drive in the ON position When SW1 7 is ON preset When doing a preset operation the amount of error in moving to the pan and tilt positions is 1 2 degree You may get erratic operation if you command the dome to go to an undefined preset 99 becomes 32 Presets 33 and 34 are fixed commands you cannot program them Preset 33 is the flip 98 becomes 31 command which pans the dome drive 180 degrees from its current position Preset 34 is 97 becomes 30 the pan zero command which directs the dome drive to the factory determined zero 96 becomes 29 reference point The following presets are reserved for special functions 95 becomes 28 94 becomes 27 Preset Function 93 becomes 26 1 Park 92 becomes 25 33 Flip command 91 becomes 24 34 Pan zero command 90 becomes 23 90 93 Limit stops 95 Select camera programming menu T 96 Stop a scan If the limit stops are turned i off refer to the Limit Stops 97 99 Activate scanning section presets 23 26 can In the following sections sometimes a number in parentheses follows a preset This second be used as regular presets number is for 32 preset mode conversion that lets Pelco s presets work with American Dynamics controllers If you are using an American Dynami
37. utter speeds Auto 1 125 1 500 1 1 000 1 2 000 1 4 000 1 10 000 In the Auto setting the camera controls the shutter speed automatically Increasing the shutter speed lowers the light sensitivity but rapidly moving objects will be less blurred as the speed is increased To change the electronic shutter speed settings On the main menu move the joystick up or down to position the cursor gt beside Camera Press the Iris Open button to enter the Camera submenu Move the joystick up or down to position the cursor beside Next Press the Iris Open button to go to the next camera submenu Move the joystick up or down to position the cursor beside Shutter Speed Press the Iris Open button The cursor moves to the right beside the current shutter speed Move the joystick up or down to choose the shutter speed SELECT Press the Iris Open button to select your choice CANCEL Press the Iris Close button if you do not want to change the setting o xoc RON AUTO FOCUS MODE The two auto focus modes are auto and off If auto focus is in auto mode pressing the Focus Near or Focus Far button places the focus in manual mode The dome returns to auto focus if you pan or tilt the unit or do a zoom function If auto focus is set to off the dome operates in manual mode with one exception If you issue a command to go to a preset auto focus turns on and remains on until you press the Focus Near or Focus Far button Pelco Manual C149