Home

Powercom 1200VA User's Manual

image

Contents

1. 800VA 1000VA 1200VA 1500VA 2200VA REAR PANEL 3 10 MAIN SWITCH 3 11 REMOTE PORT COMPUTER INTERFACE Provide both RS 232 and relay signal to support NOVELL UNIX DOS WINDOWS and other operating systems 3 12 TEL MODEM SURGE PROTECTION Surge protection for telephone and modem line to have the complete safety connection for INTERNET service 3 13 SITE WIRING FAULT INDICATORS RED LED It comes on when the UPS is connected to an improperly wired AC power outlet Note This device is available on 110 Vac model only 3 14 SURGE PROTECTION OUTLET The full time surge protection outlet provides protection from surges such as those created by lighting or connected equipment which has high initial current Plug equipment that does not require power during a utility power failure into the outlet This could include a printer scanner fax audio device and power generator 3 15 EXTERNAL BATTERY PACK CONNECTOR optional Caution Use only factory supplied or authorized connecting cable for external battery 3 16 OUTPUT POWER RECEPTACLES 3 17 AC INPUT POWER RECEPTACLE 3 18 INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle s capacity The center plungers of the circuit breakers extend when tripped 3 10 3 15 3 12 3 11 3 11 3 12 wb E m FR o oe 3 10 lo
2. UPS Uninterruptible Power System Line Interactive Network UPS 800VA 1000VA 1200VA 1500VA 2200VA USER S MANUAL Printed in USA Important safety instructions Thank you for selecting this uninterruptible power system UPS It provides you with better protection for connected equipment Please read this manual This manual provides safety installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question Please save or recycle the packaging materials The UPS s shipping materials were designing with great care to provide protection from transportation related damage These materials are invaluable if you ever have to return the UPS for service Damage sustained during transit is not covered under the warranty Table of contents RON 2SCOJXOJIAONa INtroOodUCTION 0 n ce eee 1 Safety erine a dz Presentation umumsmenemun 3 Front Panel 3 Rear Panel ruruuuumnmunemeneme A Installation Braten 5 Operation uunemememennmemumem f REaArN See Software Options 2 4 9 Computer Interface Port 10 Battery replacement 11 Troubleshooting 12 STO Fade 12 Specifications
3. Use tools with insulated handles Caution Risk of electric shock hazardous live parts inside this unit are energized from the battery supply even when the input AC power is connected Caution Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Warning To reduce the risk of fire replace only with the same type and rating of fuse Warning To reduce the risk of fire or electric shock install in temperature and humidity controlled indoor area of conductive contaminants 3 Presentation FRONT PANEL 3 1 REPLACE BATTERY indicator RED LED The LED illuminates when the UPS s battery is no longer useful and must be replaced 3 2 BUCK AVR VOLTAGE REDUCTION indicator YELLOW LED The LED illuminates when the UPS is correcting a high utility voltage condition The loads receive normal power 3 3 BACK UP indicator YELLOW LED The LED illuminates when the UPS is supplying battery power to the loads 3 4 BOOST AVR VOLTAGE BOOST indicator YELLOW LED The LED illuminates when the UPS is correcting a low utility voltage condition The loads receive normal power 3 5 LINE NORMAL indicator GREEN LED 3 6 ON OFF TEST SILENCE button Press the button more than 2 seconds to turn the UPS on or off press the button less than 1 second to activate the UPS s self testing or silence the back up alarm N
4. Continue beeping sound Bi directional communication port Interface Meet IEEE 587 standard cUL TUV CE meet FCC ENVIRONMENT Ambient 3 500 meters max elevation 0 95 humidity non condensing torage operation 0 48 deg C Audible noise lt 48dBA 1 meter from surface 15000 meters max elevation condition 1999 Powercom Co Ltd All right Reserved All trademarks are property of their respective owners Specifications subject to change without notice 14
5. not pushed or button more than 1 second push too short Battery voltage less Recharge the ups at least 4 than 10V hours PCB failure Replace the PCB call for service Load less than 20W at Normal condition battery mode UPS always at Power cord lose Replug the power cord battery mode AC FUSE burn out Replace the AC fuse Line voltage too high Normal condition too low or black out PCB failure Replace PCB call for service Back up time battery not fully charged Recharge the UPS at least 4 too short hours PCB failure Replace PCB call for service Buzzer Remove the noncritical loads continuous beeping Replace battery call for service 11 Storage 10 1 Storage conditions Store the UPS covered and upright in a cool dry location with its battery fully charged Before storing charger the UPS for at least 4 hours Remove any accessories in the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary draining the battery 10 2 Extended storage During extended storage in environments where the ambient temperature is 15 to 30 C 5 to 86 F charge the UPS s battery every 6 months During extended storage in environments where the ambient temperature is 30 to 45 C 86 to 113 F charge the UPS s battery every 3 months 13 12 Specifications MODEL KIN KIN KIN KIN KIN 800AP 1000AP 1200AP 1500AP 2200AP INPUT 800VA 1000VA 1200VA 1500VA 2200V
6. unsanuennnen 13 1 INTRODUCTION The product is line interactive UPS with the newest technology and powerful function The LINE INTERACTIVE UPS is with AVR function allows input voltage range from 75 to 125 including on line voltage boost up amp buck down An ideal protection equipment for critical connected loads It is based on microprocessor controls with utility power connected the charging is ongoing no need to switch ON the UPS and at back up mode UPS can be automatically turned OFF if none of the connected loads is operating to save the battery energy The indicator will be ON when battery needs replacement and a cyclic self testing function is included in order to verify both the operation of the UPS and the condition of the battery In addition This UPS provides advanced single telephone line or modem surge suppression through the modular connectors on the back panel The LINE INTERACTIVE UPS and RUPS seies monitoring software optional kits makes your computer operate intelligent and provides you with the ability of perfect protection of your critical devices Note There is no guarantee that interference to radio TV will not occur in a particular installation If this UPS causes interference to radio or television reception which can be determined by turning the UPS off and on the user is encouraged to try to correct the interference by one or more of following measures e connect the equipment to an outlet on a circui
7. utility power then open the case and take notice of the battery s polarity while install the new battery to avoid short 1 Unplug unit from AC power source and disconnect all connected equipment 2 Disconnect AC power cord from unit 3 Turn unit upside down and using a phillips screw driver unscrew the 4 screws holding the top of the unit to the bottom Put screws in a safe place for reconnection 4 Holding the top together firmly with the bottom turn the entire unit right side up 5 Carefully lift top cover off and place to the side The connecting wires and electronics will be exposed Be careful not to touch any inner components when changing the battery 6 Remove the 2 connecting wires from the battery 7 You can now easily remove the battery from the unit Caution Do not dispose of battery in fire Caution Do not attempt to open the battery Caution The following precautions should be taken when replacing the battery e remove watches rings etc e use tools with insulated handles 8 Place your new battery in the same position direction and reconnect the wires red wire position and black wire negative 9 Please follow steps 5 4 and 3 in that order to reconnect the entire unit 10 Please follow manual instructions in order to properly reconnect your equipment 12 10 Troubleshooting PROBLEM POSSIBLE ACTION TO TAKE CAUSE UPS on On off test silence Press the on off test silence LED not light button
8. A 25 at line input 50 or 60Hz 10 auto sensing OUTPUT Voltage Simulated sine wave at 100V 110 115V 120V 220V 230V 240V on battery 5 Frequency 50 or 60Hz 0 5 on battery Voltage AVR automatically increase output voltage 15 above input Regulation voltage if 9 to 25 of nominal AVR decrease output voltage AVR 13 below input voltage if 9 to 25 of nominal 2 4 milliseconds including detection time i i 2 les 2 Ano EMI RFI filter 10dB at0 15MHz 50dB at 30MHz FILTERING for xxxAP models only Overload UPS automatic shutdown if overload exceeds 110 of nominal at Protection 60 second and 130 at 3 seconds Circuit breaker for overload amp short circuit protection nit Inpu 10Base T Network UTP RJ 45 compatible jacks Cable Port Short Circuit UPS output cut off immediately or input circuit breaker protection BATTERY Type Sealed maintenance free lead acid batteries With 3 6 years typical lifetime Typical 4 hours to 90 of full capacity Recharge Time Protection Automatic self test amp Discharge protection Replace battery indicator 10 30 minutes depending on computer load PHYSICAL Net Weight 13 15 15 2 15 6 26 2 Kg lbs 28 6 33 0 33 4 34 3 57 6 Shipping Weight 14 2 16 2 16 4 16 8 28 2 Kg lbs 31 2 35 6 36 1 36 9 62 Dimension mm 130 x 382 x 201 169 x 448 x 227 WxDxH IEC 320 power inlet ALARM Slow beeping sound about 0 47Hz Back Up Rapid beeping sound about 1 824Hz
9. UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize The interface cable at UPS side must be connected to REMOTE PORT at computer side can be either COM 1 or COM 2 The other installation instructions and powerful features please refer to READ ME file Caution Use only factory supplied or authorized UPS monitoring cable 10 8 Computer Interface Port The computer interface port has the following characteristics D SUB 9 Pin Female Connector for white cable Contacts 2 Normally Onan o 1 Lo Signal High Min 1 Second D SUB 9 Pin Female Connector for purpure cable 5 Low Battery Mains Failure gt Common UPS Shut Down or RS232 RD Pin 3 RS232 TX Pin 2 RS232 RTS Pin 7 RS232 DTR Pin 4 No Connection Pin Number pa 5 Low Battery Contacts o 2 Mains Failure Normally Onan o o Common Signal High Min 1 Second 11 _ 7 UPS Shut Down or E RS232 RD Pin 3 RS232 TX Pin 2 RS232 RTS Pin 7 RS232 DTR Pin 4 No Connection Pin Number 9 Battery Replacement Your battery should run any where from 3 5 years before eve needing to be replaced Please follow the instructions below for easy battery replacement Note When replace battery disconnect the
10. al Connect a single line telephone or a modem line into the telephone modem surge protection sockets on the back of the UPS The RJ 45 RJ 11 modular sockets accept standard single line telephone connections This connection will require another length of telephone cable supplied Note This connection is optional It is not necessary to use this UPS Caution The telephone line current limiting feature could be rendered inoperable if improperly installed Make sure that the telephone line from the wall is plugged into the connector marked IN and the device to be protected telephone modem etc is plugged into the connector marked OUT Caution This surge protection device is for indoor use only and never install telephone wiring during a lightning storm 4 5 Connect to Utility Connect the AC input power connector to utility power to power up the UPS 4 6 Charge the battery The UPS charges its battery whenever it is connected to utility power For best results charge the battery for 4 hours in the initial use 4 7 Connect the loads Plug the loads into the output connectors on the rear of the UPS To use the UPS as a master on off switch make sure all of the loads are switched on Caution Never connect a laser printer or plotter to the UPS with other computer equipment A laser printer or plotter periodically draws significantly more power than when idle and may overload the UPS 4 8 Check the Site Wiring Fault Indica
11. battery LED does off and the on line LED goes on steady If the UPS fails the self test it immediately returns to on line operation and lights the replace battery LED The loads are not affected Recharge the battery overnight and perform the self test again If the replace battery LED is still on ask our nearest dealer to replace battery 5 4 Silence In BACK UP mode push ON OFF TEST SILENCE less than 1 second to silence the audible alarm The function is void when under condition of LOW BATTERY or OVERLOAD Note At back up mode UPS can be automatically turned off if none of the connected loads is operating 5 5 Cold start When the UPS is off and there is no utility power use the cold start feature to apply power to the loads from UPS s battery Press the ON TEST button see section 3 1 for location of the indicator on the front panel until the UPS beeps 5 6 Shutdown mode In shutdown mode the UPS stops supplying power to the load waiting for return of utility power If there is no utility power present external devices e g Servers connected to the computer interface can command the UPS to shutdown This is normally done to preserve battery capacity after the graceful shutdown of protected servers The UPS will scroll the front panel indicators sequentially in shutdown mode 6 1 BACK UP slow alarm When in BACK UP mode the YELLOW LED illuminates and the UPS sounds an audible alarm The alarm stops when the UPS retur
12. ge MI oie 3 13 316 1 i Mm a foo NT 3 16 al 0 14 3 14 d O OUTPUT SURGE PROTECTION m Am Tin A mm 1 aD y DAD a EST a8 a RE 3 15 Ta en 8 317 6 De Tt 3 18 D A a 3 17 800VA 1000VA 1200VA 2200VA 1500VA 4 Installation 4 0 Inspection Inspect the UPS upon receipt The packaging is recyclable save it for reuse or dispose of it properly 4 1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust Do not operate the UPS where the temperature and humidity is outside the specified limits 4 2 Connect Computer Interface optional UPSMON series software or other power management software and an interface kits can be used with this UPS Use only kits supplied or approved by the manufacturer If used connect the interface cable to the 9 pin computer interface port on the back panel of the UPS Note Computer interface connection is optional The UPS works properly without a computer interface connection Caution Use only factory supplied or authorized UPS monitoring cable 4 3 Connect external battery pack optional Before connecting make sure the external battery pack and the connector cable are compatible with this UPS Note External battery connection is not necessary The UPS works properly without a external battery pack connection Caution Use only factory supplied or external battery connection cable 4 4 Connect the telephone modem lines option
13. ns to LINE NORMAL operation Press the ON OFF TEST SILENCE button during on battery alarms to stop the beeping 6 2 LOW BATTERY rapid alarm In BACK UP mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE NORMAL operation 6 3 OVERLOAD continuous alarm When the UPS is overloaded the connected loads exceed the maximum rated capacity the UPS emits continuous alarm to warn a overload condition Disconnect nonessential load equipment from UPS to eliminate the overload 6 4 REPLACE BATTERY continuous alarm The UPS emits continuous beeps and the REPLACE BATTERY LED illuminates if the battery fails the self test See section 9 to replace battery by yourself or call your dealer for services 7 Software options 7 1 Power Monitoring Software The UPSMON series software or other power monitoring software is applied standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a computer in the event of power failure Moreover UPSMON displays all the diagnostic symptoms on monitor such as Voltage Frequency Battery level and so on The software is available for DOS Windows 3 1x Windows 95 Windows NT V3 5 or later Novell Netware and others Call your dealer for more information on computer OS compatible solutions 7 2 Interface Kits A series of interface kits is available for operation systems that provide
14. t different from that to which the receiver is connected O increase the separation between the equipment and the receiver e reorient the receiving antenna 2 Safety CAUTION e To reduce the risk of electric shock disconnect the UPS from the mains supply before installing a computer interface signal cable Reconnect the power cord only after signaling interconnections have been made e The internal energy source the battery cannot be de energized by the user The output may be energized when the unit is not connected to a mains supply e The right way to de energize the UPS properly in an emergency is to move the I O switch to the OFF position and disconnect the power cord from the mains supply e The socket outlet shall be installed near the equipment and easily accessible e Attention hazardous through electric shock Also with disconnection of this unit the main hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole when maintenance of service work inside the UPS is considered e Do not dispose of batteries in a fire the battery may explore e Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes e A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects
15. tor After plugging in the loads and the UPS check the site wiring fault indicator on the rear panel See section 3 17 for location of the indicator on the back panel It lights if the UPS is plugged into an improperly wired AC power outlet Wiring faults detected include ground hot neutral polarity reversal and overloaded neutral circuit Note This device is available on 110 Vac model only 5 Operation 5 1 Switch on With the UPS plugged in turn on MAIN SWITCH on rear panel and press ON OFF TEST SILENCE button on front panel less than 2 seconds to switch the UPS on The UPS will perform self testing each time when it is switched on Note When switched off the UPS maintains the battery charge and will respond to commands received through the computer interface port 5 2 Switch off By pressing and holding ON OFF TEST SILENCE button until the LINE NORMAL or BACK UP LED off To save battery power turn off MAIN SWITCH on rear panel if you leave the UPS along over one day 5 3 Self test Use the self test to verify both the operation of the UPS and the condition of the battery In normal utility power push the ON OFF TEST SILENCE button less than 1 second and UPS performs a self test function During the self test the UPS operates a back up mode Note During the self test the UPS briefly operates the loads on battery the on battery LED comes on If the UPS passes the self test it returns to on line operation The on

Download Pdf Manuals

image

Related Search

Related Contents

PR3 - Owners Manual - AJP Motorcycles America  Télécharger le dossier  MANUAL DE CODIFICAÇÃO 28  LASER SAFETY MANUAL - Case Western Reserve University  MANUAL DE INSTRUÇÕES - Shopping do Laboratório  あぜぬり機 VZR301E/351E  Emerson Miscellaneous Brochures and Data Sheets  PULSOR 300 / 350 / 400 / 500 / 400 Mt° / 600 Mt° OPERATING  Echelle de piscine  Télécharger la fiche technique  