Home

Planet Technology 170S8FB User's Manual

image

Contents

1. Q PLANET Networking amp Communication ICS 100 ICS 102 ICS102 S15 RS 232 RS 422 RS 485 over Fast Ethernet Media Converter Cost effective solution for RS 232 RS 422 RS 485 to Ethernet application PLANET ICS 10x series Media Converter Device Server provide to converts Serial RS 232 RS 422 RS 485 communication interface over Fast Ethernet networking There are RJ 45 and SC connectors and single mode multi mode media for your needs Ethernet signal that allows two types of segments to connect easily efficiently and inexpensively This converter can be used as a stand alone unit or as a slide in module to the PLANET Media Converter Chassis MC 700 MC 1000 and MC 1500 It s time saving expense for user and SI no need to replace the existing Serial equipment and software system Extend distance It extends the distance of deploying Serial equipments and hosts The selectable fiber Optic wires on the basis of distance are provided Therefore this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation Remote Manageable The ICS 10x make connected Serial equipment becomes IP based That also makes them be able to connect to a TCP IP networking immediately Each Web Smart converter is able to manage Web Interface The powerful Web Smart Media Converter supports Application mode Serial operation mode connect alarm an
2. a Chassis MC 700 1000R 1500 e LED indicators for easy network diagnose e Reset Button at the front panel for reset to factory default Q PLANET Networking amp Communication APPLICATIONS Access Control System traditional installation Most of the enterprise and government use access control plate and Mifare or RFID to authorize entrance identity With traditional deploy access control machine use RS 232 or RS 485 serial interface and cables connect to login server With connection to ICS 10x Serial over Fast Ethernet Converter the access control machine is able to be extend over longer distances via fiber optical interface The distance can be up to 20km in a local range Or the ICS 10x can be linked to a XDSL router to get the internet access capability the access control can be set and monitored over the internet Process Control To monitor configure and manage the Robot conveyer including other machines in manufacturing PLC Programmable Logical Control is required The PLC is used to drive above the manufacturing process The ICS 10x can be set to TCP Server mode and connect the PLC The administrator can configure and set command settings through Fast Ethernet intranet to control the PLC the administrator and workstation There is no need to be always by the side of the I O machine RTU Data Collect UDP Mode Connect with RTU Remote Terminal Unit to collect and monitor the data of waves signa
3. d IP address etc It helps reduce the amount of valuable time that a network administrator spends detecting and locating network problems otherwise it requires visual inspection of cabling and equipment Multiple connection options for large networking environment are available as well Data Sheet KEY FEATURES SERIAL INTERFACE e One RS 232 422 485 port to one 10 100Base TX or 100Base FX Media Converter e Cost effective solution for RS 232 to Ethernet application e Supports RS 232 4 wire RS 422 or 2 4 wire RS485 operation e Asynchronous serial data rates up to 921600b s ETHERNET INTERFACE e Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX standard e Supports auto MDI MDI X function on RJ 45 Port e Choice of fiber connector from SC multi mode single mode fiber SMART FUNCTIONS e Standard TCP IP interface and versatile operation modes e Software Protocol Support ARP ICMP TCP IP UDP HTTP server DHCP client Telnet server client e Built in IP Base Web interface for remote management e Serial Operation mode selected via Web management e Pair Connection mode for connecting two serial devices over a network e PLANET Smart Discovery utility automatically finds xxx devices on the network e Firmware upgrade via HTTP protocol HARDWARE e Compact size for easy Installation gt Standalone Wall mountable or DIN Rail mounting Optional accessory gt Co work with PLANET MC family Medi
4. gree C Operating Humidity 10 90 RH Storage Humidity 5 90 RH Emissions FCC Class A CE Certification Class A e IEEE 802 3 10Base T Standards e IEEE 802 3u 100Base TX 100Base FX Regulatory Approval Compatible Media Converter Chassis Note e EIA TIA RS 232 422 485 RoHS MC 700 1000R 1500 Reset Button at the rear panel for reset to factory default ICS 100 ICS 102 SPECIFICATION ICS 102515 Product RS 232 RS 422 RS 485 over Fast Ethernet Media Converter Model ICS 100 ICS 102 ICS 102S15 Serial Port Interface RS 232 RS 422 RS 485 Connector 3 in 1 DB9 Baud rate Data Rate 110bps to 921K bps Data Bits 5 6 7 8 Stop Bit le Flow Control None RTS CTS Xon Xoff RS 232 TxD RxD RTS CTS DTR DSR DCD GND enal RS 422 Tx Tx Rx Rx RS 485 2 wire Data Data RS 485 4 wire Tx Tx Rx Rx Fast Ethernet Port Standard 10 100Base TX 100Base FX Connector RJ 45 SC Mode Multi Mode Single Mode Distance 100m 2km 15km Optical Wavelength 1300nm 1310nm 50 125um or 62 5 125um 9 125um Sale irene multi mode fiber cable single mode cable Protection Built in 1 5KV magnetic isolation Hardware Q PLANET Networking amp Communication ICS 100 ICS 102 ICS 102S15 ORDERING INFORMATION ICS 100 RS 232 422 485 over Fast Ethernet Media Converter RJ 45 100m ICS 101 RS 232 422 485 over Fast Ethernet Media Converter ST MM 2km ICS 102 RS 232 422 485 over Fast Ethernet Media Conve
5. l and power utilization ICS 10x can be used set up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server automatically Surveillance motion control Pair Connection Mode Using pair connection along with fiber optical patch cord the ICS 10x extend RS 232 RS 422 RS 485 interfaces distance from surveillance and scanner to the control keyboard joystick which is installed in the remote monitor center Data Sheet ICS 100 ICS 102 ICS 102S815 Fees Coe TOF irna pig al iy lt E L E a 5 ff i th Be Ciera pee SSE Conair TOP ener rras g at aati RTL labiimak i Remobe Tamina i Unti aee i r oe hem iI LI RTU a a te ao m E e ch TE aa 1m D oe Y uhar Res rrei Cornentor ise Corra Ciri kamar Q PLANET Networking amp Communication Data Sheet LED Indicators Management Operation Mode Dimension W x D x H System Power TP or Fiber Port Link Active Serial Port Serial port mode RS 232 RS 422 or RS 485 Web Management PLANET Smart Discovery Utility VCOM Virtual COM Port TCP Server TCP Client UDP Client Pair Connection 97 x 70 x 26 mm Weight 200g Power Supply External Power Adaptor 5V DC 2A max Power Consumption 5 5 Watts max Mechanical Metal Environment Operating Temperature 0 50 Degree C Storage Temperature 10 70 De
6. rter SC MM 2km ICS 102515 RS 232 422 485 over Fast Ethernet Media Converter SC SM 15km ICS 105A RS 232 422 485 over Fast Ethernet Media Converter SFP Vary on module Upon by request ACCESSORIES RKE DIN DIN Rail Mounting Kit AVAILABLE MODULES FT 80x 10 100Base TX to 100Base FX Fast Ethernet Media Converter FT 90x 10 100Base TX to 100Base FX Web Smart Media Converter FST 80x 10 100Base TX to 100Base FX Fast Ethernet Media Converter IFT 802 Industrial 10 100Base TX to 100Base FX Smart Media Converter MC 700 10 7 Slot Media Converter Chassis McC 1000R 19 10 Slot Media Converter Chassis Optional Redundant Power Mc 1500 19 14 Slot Media Converter Chassis PLANET Technology Corporation Data S h eet 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C FC C 3 Tel 886 2 2219 9518 Fax 886 2 2219 9528 04 08 C ICS10X Email sales planet com tw www planet com tw PLANET reserves the right to change specifications without prior notice All brand names and trademarks are property of heir respective owners Copyright 2008 PLANET Technology Corp All rights reserved 4 VoIP Gateway vip planet com tw i p

Download Pdf Manuals

image

Related Search

Related Contents

Technaxx Actionmaster 4GB  MELSEC iQ-R Temperature Control Module User`s Manual  User Guide - Postordershop.nl  取扱説明書  User Guide - Verizon Wireless  Edimax EN-9235TX-32 V2  Bandbunker BB-TB60 Deutsch  Wyse Webcam 060413 User's Manual  quotation: the insertion of two statements of Proust in a novel    

Copyright © All rights reserved.
Failed to retrieve file