1. has two large pins and two small pins It will only insert one way Place end of flash tube into spring support then insert base pins into socket Please insert carefully to avoid damage or injury With all lamps and flash tubes securely installed replace diffusion panel it doesn t really matter which side is in or out Panel may catch on lip of frame If required turn unit on face to insert panel Replace L bracket and thumbscrews To set up the unit first mount and secure it on a suitable stand The Skylighter stand adapter allows the unit to be mounted on a stand with a 3 8 to 5 8 post Be sure to use a stand that is stable and will not tip easily With power switch OFF attach the cable to the circular input connector located on the back of the Skylighter and connect the other end to the purchased PowerLight power supply See PowerLight instructions for installation and operation PowerLight modeling light controls must be set to FULL ON for Skylighter fluorescent modeling lamps to function Only then turn on the Skylighter power switch THE FLUORESCENT MODELING LAMPS ARE NOT ADJUSTABLE ANY ADJUSTMENT BY THE POWERLIGHT MODELING WILL DAMAGE THE SKYLIGHTER INTERNAL BALLAST S Power Input The power required to operate the Skylighter fluorescent lamps is 105 to 125 volts AC 60 Hz and this power comes from the PowerLight through its line cord Circuit Protection All circuit protection for the Skylighter is pr
2. Photogenie Skylighter Brand Fluorescent Strobe Lighting Operator s Manual Skylighter CFF2 Skylighter CFF4 Skylighter CFF8 OPERATOR MANUAL FOR SKYLIGHTER Skylighter CFF2 Skylighter CFF4 Skylighter CFF8 Thank you for selecting the Photogenic Professional Skylighter CFF series The CFF series incorporates the newest electronic components lamps reflectors and diffusion panels providing improved lighting distribution and control These products are built for the demanding operational needs of the professional photographer and it is our expectation that your Skylighter CFF will provide you with years of dependable service INTRODUCTION The Skylighter CFF series are an extremely diffused light head and require an external power supply They have one two or four professional plug in linear flashtubes and one two or four non adjustable linear fluorescent modeling lamps The Skylighter CFF series are stand mounted on a strong rotating yoke but may be ceiling hung as required Before using your new Skylighter CFF for the first time please read this manual carefully and acquaint yourself with the controls and features In this way you can quickly get the greatest benefit from your new unit and maintain an efficient and safe operation SAFETY PRECAUTIONS Despite the measures that have been taken to make electronic flash equipment safe it must be recognized that high voltages and high temperatures do exist with
3. d for any damage which may have been caused by rough handling during shipment If any damage is detected contact the delivering carrier at once Claim for damage should be made to the delivering carrier before destroying packing cartons Unpacking and Setup The unit is shipped with the modeling lamps and flashtubes not installed While installing the modeling lamps and flashtubes with glove or clean cloth to protect the hand be sure they are properly inserted and tight to avoid arcing and failure of the socket contacts during operation Always use a clean cloth or wear gloves to protect your hand from glass breakage and heat Place the unit on a stable flat surface face up The diffusion panel is held in place with an L bracket and thumbscrews Remove the thumbscrews and L bracket Slide out the diffuser panel The paper protective sheet must be peeled off the diffusion panel Use finger nails to start peeling at two corners and continue carefully peeling protective sheet until it is all removed Do not use razor blade or other mechanical scrapers The fluorescent lamps have no polarity Remove any plastic film from reflector Install by inserting the glass body into the clear support bracket and then insert the pins into the top of the socket holes and press base down to snap pins into contacts Removal is accomplished by first lifting the lamp base to release pins from contacts The flash tubes are polarized Their base
4. in the power supply lighting unit Certain precautions must be observed in handling the unit Contact with internal high voltage may result in severe injury or death 1 Before installing or removing the flashtubes and modeling lamps be sure this appliance is turned off cooled and unplugged from AC power source and external power supply 2 Do not operate this appliance with a frayed or damaged cable 3 Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 4 Do not operate the unit with a damaged or broken flashtube or modeling lamp Do not use flashtubes with broken cracked or missing glass envelopes To prevent damage always use Photogenic specified replacements for the flashtubes and modeling lamps 5 Perform no internal service work on this unit Refer all such service to a qualified service person or return to the factory This will provide you safety and continuation of your warranty 6 Do not operate when water is present and from extreme temperature shifts If the unit is stored in hot or below freezing temperatures allow at least one hour at room temperatures before using PREPARATION AND BASICS Unpacking and Setup Unpack all units carefully to remove all parts from the carton s Do not discard or destroy the packing material until the equipment has been inspected assembled and all parts accounted for After unpacking all parts should be examine
5. ovided by the PowerLight power supply Power switch The power switch controls only the modeling lamps Flash Power See the PowerLight power supply instructions The Skylighter flash power is fully controlled by all features and functions of the PowerLight power supply to which it is attached SPECIFICATIONS Skylighter CFF2 Skylighter CFF4 Skylighter CFF8 General CFF2 CFF4 CFF8 Flash Power 1000 ws max 1000 ws max 1000 ws max Modeling Light 55 watt 110 watt 220 watt Power 300 w incad 600 w incad 1200 w incad Modeling Light FULL ON FULL ON FULL ON Control Flash Overload 15 amp power 15 amp power 15 amp power Protection supply fuse supply fuse supply fuse Modeling 5 amp power 5 amp power 5 amp power Overload supply fuse supply fuse supply fuse Protection internal internal internal Packaging Aluminum case Aluminum case Aluminum case Weight 11 lbs 16 lbs 28 lbs Dimensions Box only Box only Box only 23 W x 9 H 23 W x 17 H 23 W x 33 H With yoke With yoke With yoke 26 W x 14 H 26 W x 21 5 H 26 W x 37 5 H Flashtube 1 each 2 each 4 each Plug in style Plug in style Plug in style use only use only use only Photogenic s Photogenic s Photogenic s Standard L4 6 Standard L4 6 Standard L4 6 Modeling Lamp 1 each 2 each 4 each Plug in style Plug in style Plug in style use only use only use only Photogenic s Photogenic s Photogenic
6. s Standard F56 Standard F56 Standard F56 Exposure Information Given as f stop measurements made on a wall grid of 1 ft by 1 ft squares with the light source centered on the grid center and placed a fixed distance from the wall The center number is the actual meter reading The other numbers are the relative change in readings with meter position always at grid crossings Minolta Flash Meter V time 1 125 sec iso 125 CFF at 5 ft from wall Fluorescent lamp only CFF at 5 ft from wall Fluorescent lamp and Flash 3lws amp 125ws CFF2 at 5 ft from wall Fluorescent lamp and Flash 250 500 1000ws 1 2 1 0 0 6 0 5 0 6 0 5 0 6 1 0 1 2 CFF4 at 5 ft from wall Fluorescent lamps only 1 1 1 0 0 5 0 5 0 5 0 5 0 7 1 0 1 1 CFF4 at 5 ft from wall Fluorescent lamp and Flash 31 63 125 250 500 1000ws 1 1 1 0 0 6 0 5 0 4 0 5 0 6 1 0 1 1 CFF4 at 10 ft from wall Fluorescent only and Flash 31 125 1000ws 0 5 0 2 0 5 CFF8 at 5 ft from wall Fluorescent lamp and Flash 31 63 125 250 500 1000ws CFF8 at 10 ft from wall Fluorescent lamp and Flash 31 125 250 1000ws SERVICE The photographer should not attempt to make repairs Consult a dealer for an authorized Photogenic Professional Lighting service agent This will provide you safety insure proper opera
7. tional functions and provide continuation of your warranty For replacing the flashtube or modeling lamp follow the directions and specifications given earlier in this manual in the setup section Before removing the old tubes or installing new tubes always unplug your Skylighter and PowerLight generator and discharge the stored energy by pressing the test button Unplug the cable connecting the Skylighter to the PowerLight generator It is now safe to change the lamps in the Skylighter General Trouble Shooting COMMON PROBLEMS AND CAUSES Unit does not flash Probable causes a No power Check cable connections and PowerLight generator status b One or more tubes not flashing Flash tube jarred loose or broken from rough transport Check Modeling light does not turn on Probable causes a Switch OFF Turn ON b No power Check that PowerLight generator is set to FULL ON c Lamp burned out Inspect and replace when cool See SERVICE section of this manual Limited PowerLight Warranty Photogenic warranties the standard line products are free from defects in material and workmanship of the PL2 series of PowerLights for a period of three years At our choice we will repair or replace any PL2 series light that is deemed to be defective This warranty does not cover damages caused by shipping product abuse or use other than the intended photographic applications Any product modifications will render this
8. warranty void Use of other manufacture s accessories which restrict normal or intended operation especially venting airflow may cause damage and will void this warranty otogenic rofessional lighting Photogenic Professional Lighting 1268 Humbracht Circle Bartlett Illinois 60103 www Photogenicpro com Telephone 630 830 2500 Fax 630 830 2525 MANUAL PART NO 016341 00V3 05