PHD Products PHD Carbon Monoxide Alarm 13-027 User's Manual

image

Contents

1. 1 1 7 Other alarms and special microprocessor features Combustible sensor over limit alarm latch Protective software latches the combustible alarm when the sensor is exposed to 100 LEL combustible gas The alarm sounds continuously until the instrument is manually reset Discussed in detail in Section 3 2 2 Missing or failed combustible sensor Display shows X instead of normal combustible gas reading This alarm will not be triggered when sensor failure is due to poisoning Over limit or failed toxic gas sensor Numeric toxic gas readings of affected sensor blink Downscale or negative reading alarm Audible and visual alarms for the affected sensor are activated when negative readings equal one half of TWA alarm value As an example if the TWA alarm is set at 15 PPM readings of minus 7 5 PPM would activate this alarm Several automatic prograrnis prevent tampering and misuse of the PhD by unauthorized persons Each time the detector is turned on an electronic self test is performed that assures the user of proper performance The sensors the LED alarm lights and audible alarm are automatically tested and the battery is monitored continuously for proper voltage A diagnostic routine for advanced PhD users or service technicians provides a means for technical evaluation of sensor performance The PhD automatically remembers logs gas readings as well as other important information such as turn on
2. RELATIVE LEL METER RESPONSE 20 40 60 80 ACTUAL LEL CONCENTRATION Note that the response to the gas to which the instrument was calibrated the calibration standard is still precisely accurate For the other gases the responses are a little off In the case of some gases the readings are a little high This results in the instrument going into alarm a little bit early This type of error is not dangerous since it results in workers exiting the affected area sooner than they absolutely have to Gases which produce lower relative readings than the calibration standard can result in a more potentially dangerous sort of error In the chart example above the worst case gas only produces a meter reading of 50 percent LEL even when the actual concentration is 100 percent explosive If the alarm were set to go off when the display reads 50 percent LEL the alarm would sound simultaneously with the explosion If on the other hand the alarm is set to go off when the display reads 20 percent LEL a 50 percent concentration of the same worst case gas is enough to cause an alarm It may be seen from the graph that the amount of relative error decreases the lower the alarm point is set If the alarm point is set at 10 percent LEL the differences due to relative response of the combustible sensor are minimal The best results are obtained when calibration is done using the same gas that is expected to be encou
3. Basic mode current gas level screen If an alarm condition occurs that is when one of the sensor readings exceeds a pre set alarm level the numerical reading changes to reflect the new value the LED alarm light flashes and the audible alarm sounds PhD alarms are normally self resetting When readings drop back below the pre set alarm levels visual and audible alarms cease and normal operation of the instrument resumes Pressing the large black MODE button allows the user to toggle between available meter display screens Two screens are available to the user in Basic mode The first screen is the gas level display discussed above Pressing the MODE button displays the second screen which shows clock time number of data points saved temperature run time and battery voltage Pressing the MODE button again toggles the display back to the first screen showing current gas levels No matter which mode is selected anytime the PhD is on it is remembering the peak readings of all gases measured and is calculating both long term Time Weighted Averages and Short Term Exposure Levels for the toxic gases and will go into alarm whenever appropriate 2 2 3 Technician mode The Technician Mode provides access to all advanced functions and displays Although it is possible to make a fresh air zero adjustment while in the Basic mode it is necessary to be in the Technician Mode before beginning the span calibration p
4. QUIPMENT DOIT ETRE UTILIS ENTRETENU ET R PAR UNIQUEMENT PAR UN PERSONNEL QUALIFI TUDIER LE MANUEL D INSTRUCTIONS EN ENTIER AVANT D UTILISER ENTRETENIR OU DE R PARER L QUIPMENT CAUTION ANY RAPID UP SCALE READING FOLLOWED BY A DECLINING OR ERRATIC READING MAY INDICATE A GAS CONCENTRATION BEYOND UPPER SCALE LIMIT WHICH MAY BE HAZARDOUS AVERTISSEMENT TOUTE LECTURE RAPIDE ET POSITIVE SUIVIE D UNE BAISSE SUBITE AU ERRATIQUE DE LA VALEUR PEUT INDIQUER UNE CONCENTRATION DE GAZ HORS GAMME DE D TECTION QUI PEUT TRE DANGEREUSE Signal Words The following signal words as defined by ANSI Z535 4 1998 are used in the PhD2 Reference Manual VAN By ela indicates an imminently hazardous situation which if not avoided Will result in death or serious injury ZAWARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury ZNCAUTION indicates a potentially hazardous situation which if not avoided may result in moderate or minor injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Page 5 WARNINGS AND CAUTIONS 1 A WARNING The PhD2 personal portable gas detector has been designed for the detection of dangerous atmospheric conditions An alarm condition indicates the presence of a potentially life threatening hazard and should be taken very seriously 2 AAWARNING
5. battery charger hand aspirated sample draw kit owner s manual and video training tape The sample draw kit consists of a slip on sample draw calibration adapter squeeze bulb sample probe two probe extenders and ten feet of hose Page 10 Chapter 2 Basic operation This chapter will cover how to use the PhD for safe work in potentially hazardous atmospheres 2 1 Overview of PhD2 operation The PhD offers a choice of three modes of operation Text Only Basic and Technician Mode selection is a function of how much information is required the skill level of the user and the nature of the job Regardless of operating mode selection the PhD automatically remembers logs gas readings as well as other important information such as turn on turn off times battery condition and whenever the instrument is calibrated This information may be downloaded to a computer to create a permanent record or directly displayed on the PhD meter screen Although it is not necessary to make use of this saved information it is there and available to the user 2 4 1 Turning the PhD2 on The large black push button on the top of the PhD case is called the MODE button It is used to turn the PhD2 on and off as well as to control most other operations of the instrument Pushing the MODE button once turns the PhD on 2 1 2 Start up sequence After the detector has been turned on it will automatically go through an electr
6. hydrogen cyanide and hydrogen chloride corrosive gas sensors 3 4 1 1 3 4 1 2 Chapter 4 4 1 4 2 Chapter 5 5 1 5 2 5 2 1 5 2 2 5 2 2 1 5 2 3 5 3 5 3 1 5 3 2 5 3 3 5 3 3 1 5 3 4 5 3 5 5 3 6 5 3 7 5 3 8 5 3 9 Chapter 6 6 1 6 1 1 6 2 6 2 1 6 2 2 6 2 3 6 2 4 Corrosive gas sensor functional bump test Corrosive gas sensor span adjust procedures Setting alarm levels Alarm adjustment sequence Restoring the factory default alarm settings PhD2 Advanced Functions PhD2 Advanced features overview Diagnostics Test Entering the Diagnostics Test mode Diagnostic counts Optimal diagnostic count ranges for version 4 7 PhD detectors Exiting the Diagnostics Test mode Sensor Configuration mode Entering the Sensor Configuration mode Enabling and disabling the oxygen and combustible gas LEL channels Configuring toxic gas channels Resetting the toxic sensor bias voltage Changing the precision of the toxic sensor read out Adding an instrument identification number Text Only operating mode readout latch Alarm latch command Security beep Exiting the Sensor Configuration mode Record Keeping Lr rrr PhD datalogging overview Optional Datalink and Gas Detection Database Software kit Adjusting record keeping parameters Entering the Datalogging
7. the PhD2 should be kept on the battery charger continuously whenever the instrument is not being used The battery cannot be damaged by overcharging with the Biosystems charger 2 3 3 Low battery voltage alarms When the battery voltage is reduced to 5 65 volts an audible alarm sounds and the display screen indicates a low battery condition exists It is best to leave any hazardous area in which the instrument is being used as soon as possible after a low battery alarm has been sounded At this stage the low battery alarms may be silenced for a fifteen minute period by pressing the large black mode push button The alarm will continue to sound every fifteen minutes until the voltage reaches 5 55 Volts When the battery voltage is reduced to 5 55 Volts the battery alarm will sound every 30 seconds At this point it is no longer safe to continue to use the instrument until the battery has been recharged It is necessary to leave any hazardous area in which the instrument is being used immediately When the battery voltage is reduced to 5 45 volts the PhD automatically shuts off protecting the battery from deep discharge 2 3 4 Charging procedures The PhD2 should be kept continuously on the charger at all times when not in use CAUTION Batteries may only be charged with the Biosystems PhD battery charger Use of any other charger may result in damage to the instrument and voids the standard Biosystems warranty 1 Chec
8. turn off times temperature battery condition and whenever the instrument is calibrated The PhD can store up to 3 000 data points enough for the storage of up to 50 hours of four gas monitoring broken into as many as 36 individual monitoring sessions User selectable data logging intervals allow the collection of data for monitoring projects of even longer duration This information may be downloaded to a computer to create a permanent record or directly displayed on the PhD meter screen A PhD Gas Detection Database program and Computer Link Kit is optionally available and recommended for users wishing to interface their PhD with a computer Chapter 5 describes PhD advanced technical features in greater detail Chapter 6 describes record keeping and datalogging 1 1 8 Classification for intrinsic safety The PhD is Classified by Underwriters Laboratories Inc and the Canadian Standards Association as to Intrinsic Safety for use in Hazardous Locations Class Groups A B C amp D This means that the PhD has been successfully tested for safety in combustible gas air 21 oxygen mixtures 1 1 9 Options 1 1 9 1 Sensors The PhD may be configured as a one two three or four sensor design The PhD measures oxygen combustible gas and up to two additional toxic gases The sensor configuration may be changed or added to in the field or specified at the time of purchase 1 1 9 2 Batteries Two types
9. 4 7 and higher instruments may be fresh air zeroed using either method 3 3 1 1 Fresh air zero through MODE button 1 Turn the instrument on 2 Verify that the instrument is in the Basic or Technician operating mode Switch modes if necessary by simultaneously holding down the and keys Each time that the operating mode is changed the meter screen will briefly indicate the current operating mode 3 Wait at least three minutes after turning the instrument on to allow sensor readings to stabilize fully before initiating the fresh air zero procedure 4 Make sure the instrument is located in an area where the air is known to be fresh 5 While in the normal gas reading screen press the MODE button three times within two seconds This Will wake up the instrument from normal operation and put it into the fresh air zero mode A screen will display the message Fresh Air Cal Adjustment This screen will be followed by another displaying the message Mode Adjust This screen also includes a timer which counts down the number of seconds which remain in which to choose to make the adjustment 6 Pressing the MODE button within five seconds causes the fresh air adjustment to be made An information screen is briefly displayed while the adjustments are being made and another when the adjustments have been completed 7 If the MODE button is not pushed within five seconds a fresh air zero adjustmen
10. 9 Options 1 1 9 1 Sensors 1 1 9 2 Batteries 1 1 9 3 Battery powered sample draw pump 1 1 9 4 Computer Link Kit 1 2 PhD2 design components 1 3 PhD2 accessories Chapter2 Basic operation 2 1 Overview of PhD operation 2 1 1 Turning the PhD on 2 1 2 Start up sequence 2 1 3 Turning the PhD2 off 2 2 Operating modes 2 2 1 Text Only mode 2 2 2 Basic mode 2 2 3 Technician mode 2 2 4 Changing operating modes 2 3 Batteries 2 3 1 PhD battery options 2 3 1 1 NiCad 2 3 2 Battery life 2 3 3 Low battery voltage alarms 2 3 4 Charging procedures 2 4 Methods of sampling 2 4 1 Using the hand aspirated sample draw kit 2 4 2 Using the battery operated slip on sample draw pump Chapter 3 Calibration MM O O O O O O o oo 00 NN c N e A A CQ NNN a _ C ow O A A A ao DO 3 1 3 2 3 2 1 3 2 2 3 2 3 3 3 3 3 1 1 9 9 1 2 3 4 3 4 1 Functional bump test Effect of contaminants on PhD2 sensors Effects of contaminants on oxygen sensors Effects of contaminants on combustible sensors Effects of contaminants on toxic gas sensors Fresh air zero calibration Fresh air zero through MODE button Fresh air zero through mini push buttons PhD2 span calibration Calibration procedures for sulfur dioxide ammonia chlorine
11. In the event of an alarm condition it is important to follow established procedures The safest course of action is to immediately leave the affected area and to return only after further testing determines that the area is once again safe for entry Failure to immediately leave the area may result in serious injury or death 3 NNWARNING The accuracy of the PhD2 should be checked periodically with known concentration calibration gas Failure to check accuracy can lead to inaccurate and potentially dangerous readings 4 JNNARNING The accuracy of the PhD2 should be checked immediately following any known exposure to contaminants by testing with known concentration test gas before further use Failure to check accuracy can lead to inaccurate and potentially dangerous readings 5 NNWARNING A sensor that cannot be calibrated or is found to be out of tolerance should be replaced immediately An instrument that fails calibration may not be used until testing with known concentration test gas determines that accuracy has been restored and the instrument is once again fit for use e WARNING Do not reset the calibration gas concentration unless you are using a calibration gas concentration that differs from the one that is normally supplied by Biosystems for use in calibrating the PhD2 Customers are strongly urged to use only Biosystems calibration materials when calibrating the PhD2 Use of non standard calibration gas and or calibration kit compone
12. chloride HCl ammonia NH3 and TOX 1 broad range sensors require 24 hours to stabilize 5 Recalibrate the toxic channel 7 1 2 Replacing combustible gas sensors 1 Gently pry the square sensor out of its socket 2 Press the replacement sensor into place Make sure that the sensor seats all the way down 3 Recalibrate the LEL channel 7 1 3 Replacing oxygen sensors 1 Remove the two screws and lock washers that hold the O2 sensor tabs A nylon spacer bushing separating the red positive sensor tab from coming into direct contact with the PhD case Be careful not to lose this component 2 Remove the O2 sensor 3 Place the replacement sensor in the socket and line up the sensor tabs with the screw mounting holes 4 Replace the nylon spacer sensor mounting screws and lock washers 5 Allow one hour for the sensor to stabilize 6 Recalibrate the oxygen channel in fresh air 7 1 4 Adding removing or re configuring sensors See Section 5 3 for the procedure for configuring PhD sensors 7 2 Troubleshooting There are a few troubleshooting and repair procedures besides sensor and battery replacement which can be done in the field 7 2 1 Re booting the microprocessor software Occasionally it may be necessary to re boot or cold start the PhD microprocessor software Deep battery discharge disconnecting the battery static discharge through the dual purpose RS 232 battery charger connec
13. default settings are restored and the display shows the following screen If the MODE button is pushed the current alarm settings remain unchanged and the display shows the following screen 7 After selection of the default or current alarm settings has been made the display reverts to the current gas reading screen Page 23 Chapter 5 PhD2 Advanced Functions 5 1 PhD2 Advanced features overview The PhD microprocessor circuitry makes a number of advanced features and capabilities possible Although this chapter has been designed primarily to be of benefit to experts there are several sections that may be of interest to other PhD users The four push buttons located under the keypad cover on the top of the detector are used to program advanced PhD functions The technique for using these buttons requires several buttons to be pressed and held at the same time CAUTION Do not use this technique with any other combination of buttons than those listed below Doing so may result in loss of information stored in memory The major advanced functions and set up routines available through this method are Diagnostics and Sensor Configuration The sensor configuration routine in particular controls a number of potentially useful alternative set up configurations 5 2 Diagnostics Test The Diagnostics Test mode is used to identify problems with various PhD components It is most useful in helping identify whe
14. may be used as either a Diffusion or sample Draw type monitoring device In normal operation the PhD2 detector is worn on the belt used with its shoulder strap or held by hand Once turned on the PhD2 monitors continuously The atmosphere being measured gets to the sensors by diffusing through vents in the sensor compartment cover Normal air movements are enough to carry the sample to the sensors The sensors react immediately to changes in the concentrations of the gases being measured This type of diffusion operation monitors only the atmosphere that immediately surrounds the detector It is possible to use the PhD to sample remote locations by using a sample draw kit Two sample drawing kits are available In each case the sample is drawn in through a probe assembly and ducted through a length of hose back to the instrument One type of kit uses a hand operated squeeze bulb to draw the sample through the hose the other uses a battery operated continuous mechanical pump A hand aspirated sample draw kit is included as an accessory with every PhD 2 4 1 Using the hand aspirated sample draw kit 1 Connect the slip on sample draw cup with the squeeze bulb and hose assembly Connect the end of the hose closest to the bulb to the sample draw cup Connect the other end of the hose to the sample probe Screw one or two probe extenders into the barrel of the sample probe 2 Remove the PhD from its protective vinyl carry
15. mode and returns the instrument to the gas reading screen 8 When the desired alarm adjust option has been reached the and keys are used to raise or lower the alarm set point 9 When all alarm adjustments have been completed press and hold the Alarm button down until an information screen indicates that alarm adjustment is complete ADJUST The instrument will automatically return to normal operation 4 2 Restoring the factory default alarm settings PhD alarm settings are set at the factory in the most conservative way possible See Appendix B It is possible to restore these default settings at any time by doing the following 1 Turn the instrument on and make sure it is in the Technician Mode See Section 2 2 4 2 Press the Alarm button on the instrument keypad The display will briefly show the following screen 3 This screen will be followed by several more showing the specific default alarm settings for each type of sensor installed These screens will be shown in continuous rotation In the case of a PhD with combustible oxygen carbon monoxide and hydrogen sulfide sensors installed the following sequence of screens would be shown Oxygen and combustible gas Toxic gas ceilings Toxic 1 STEL and TWA Toxic 2 STEL and TWA 4 5 6 The final screen in the sequence indicates how to make the adjustment If the Alarm button is pushed the
16. of the sensors installed in the PhD2 A healthy sensor will generally have an output within an expected optimum performance range Note Optimal sensor performance ranges are approximate PhD2 diagnostic counts should only be used as a gross indication of the health of the sensor Significant differences in diagnostic counts may be seen from one sensor to another Diagnostic counts may also be affected by the age of the sensor and the battery voltage Make sure that the battery is fully charged before entering the diagnostic mode with the intent of checking sensor performance Optimal ranges vary for different PhD2 microprocessor versions Make sure you have the correct optimal values for the instrument being checked The following ranges only apply to PhD detectors with version 4 7 microprocessor software installed Please contact the factory for the correct ranges for other software versions The most appropriate use of the diagnostic counts is to verify an existing suspicion that a sensor requires replacement In the event that a sensor is incapable of calibration diagnostic counts may help to determine that it is the sensor that is truly at fault and a replacement is required Using the diagnostic counts may also help to determine whether it is time to change an old out of warranty sensor that is still functional but that may approaching the end of its life 5 2 2 1 Optimal diagnostic count ranges for version 4 7 P
17. of rechargeable batteries are available for use in the PhD2 design The type of battery selected must be specified at the time of purchase NiCad A removable NiCad battery pack is available as an option with the PhD2 design The NiCad battery pack is secured by two screws located on the bottom of the PhD case and may be removed or replaced without disassembly of the instrument Sealed lead acid The PhD may also be equipped with an internally housed sealed lead acid rechargeable battery Removal or replacement of the sealed lead acid battery requires disassembly of the instrument case Chapter 2 of the PhD2 owner s manual covers battery replacement and charging procedures 1 1 9 3 Battery powered sample draw pump An optional slip on motorized sample draw pump is available for situations requiring continuous hands free remote monitoring The rechargeable UL Classified battery operated pump contains a unique pressure sensor which detects water or other fluids being sucked into the unit and immediately acts to shut off the pump in order to protect the PhD sensors pump and other components The pump design includes a loud audible alarm and bright red LED alarm light to additionally indicate a low flow condition The battery operated pump has its own rechargeable power supply On a full charge the pump should run continuously for at least eight hours 1 1 9 4 Computer Link Kit A PhD Computer Link Kit and Gas Detecti
18. of three modes of operation providing the right amount of information for users with different skill levels The PhD automatically remembers logs gas readings as well as other important information such as turn on turn off times battery condition and whenever the instrument is calibrated This information may be downloaded to a computer to create a permanent record or directly displayed on the PhD meter screen The PhD is Classified by Underwriters Laboratories Inc and the Canadian Standards Association as to Intrinsic Safety for use in Hazardous Locations Class I Groups A B C and D Classification for intrinsic safety is based on tests conducted in explosive gas air 21 oxygen mixtures only The PhD2 should not be used for combustible gas monitoring in atmospheres where oxygen concentrations exceed 23 5 oxygen ONLY THE COMBUSTIBLE GAS DETECTION PORTION OF THIS INSTRUMENT HAS BEEN ASSESSED BY THE CANADIAN STANDARDS ASSOCIATION FOR PERFORMANCE UNIQUEMENT LA PORTION POUR D TECTER LES GAZ COMBUSTIBLES DE CET INSTRUMENT A T VALU E WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY AVERTISSEMENT LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA S CURIT INTRINSEQUE CAUTION FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY READ AND UNDERSTAND THE INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING OR SERVICING ATTENTION POUR DES RAISONS DE S CURIT CET
19. protect the sensors against leakage or exposure to liquids A special sensor cover which does not include an inner liner is used whenever corrosive gas toxic sensors are installed The solid cover also provides increased sensor position stability 9 Audible alarm orifice A cylindrical orifice extending through the top of the case houses the loud 100 dBA at six inches audible alarm A water resistant Porex filter protects against leakage or exposure to liquids 10 Battery charger RS232 connector A water resistant connector on the upper left hand side of the case functions both as the battery charger and RS232 computer interface port 11 Bottom surface A sturdy clip allows the user to wear the PhD on a belt or other article of clothing A removable NiCad battery pack is available as an option If this option has been selected instead of a belt clip the battery pack is secured into the case by two screws located on the bottom of the PhD2 12 Key pad The key pad consists of four mini push buttons Cal Alarm and These buttons are used for fresh air zero adjustment calibration and programming procedures Use of these push buttons Is reserved for authorized personnel Chapter 2 of the PhD2 owner s manual covers battery replacement and charging procedures 1 3 PhD2 accessories Each PhD is delivered in a foam lined box containing the PhD detector padded vinyl weather cover carrying strap
20. screen with the oxygen channel turned on Gas reading screen with the oxygen channel turned off Press the Cal button once to advance to the combustible gas enable disable screen 5 3 3 Configuring toxic gas channels There are two toxic channels in the PhD2 design They are designated Toxic 1 and Toxic 2 Pressing the Cal button will advance to the first toxic channel set up screen Besides identifying which Toxic channel is currently being configured the screen also identifies which type of sensor has been selected In the screen example above CO indicates a carbon monoxide sensor has been selected It is possible to use the and keys to scroll through the current toxic sensor menu list CAUTION If a new toxic sensor type is selected verify that it has been properly installed in the correct toxic sensor socket Calibrate the new sensor before use Highly reactive or corrosive gases such as ammonia chlorine hydrogen cyanide and hydrogen chloride tend to react quickly with or be absorbed by other substances These reactions can occur so quickly that there may not be adequate time for the gases to diffuse through the moisture barrier in the standard PhD sensor compartment cover before they are gone ZNNARNING The standard sensor compartment cover which includes a moisture barrier may not be used as long as a corrosive gas sensor is installed When the sensors installed in your PhD include
21. sensors should be set at 0 0 mV It will be necessary to readjust the bias voltage whenever the new toxic sensor has a different bias voltage than the old one Resetting the toxic sensor bias voltage requires opening the instrument and adjusting a potentiometer located on the main circuit board of the detector This procedure should not be done by unauthorized persons In many cases it may be better to return the detector to the factory for adjustment Biased type toxic sensors may only be installed in Toxic Channel 1 The following table lists currently available toxic sensors and their appropriate bias voltages H2S SO2 Cl2 HCN HCI NH3 Note The TOX 1 broad range electrochemical sensor is designed for use in situations where it is necessary to use a single sensor to monitor for multiple atmospheric hazards When specific contaminants are known to be present the safest course is usually to select substance specific sensors and calibrate them directly to the contaminants to be measured Use of broad range sensors should be restricted to situations where this approach is not possible NO2 Use the following procedure to reset the bias voltage 1 Make sure the detector is turned off 2 The potentiometer used to adjust the bias voltage is on the back of the main circuit board Remove the five screws holding the two halves of the instrument case together in order to open the case and access this pot The bias
22. successfully calibrated While in the Sensor Configuration mode it is possible to re program the PhD with several alternative set up configurations including latching alarms timed security beeps and assigning the instrument a user defined identification number Each of these options is discussed in greater detail below 5 3 1 Entering the Sensor Configuration mode The Sensor Configuration mode is entered from the Diagnostics Test mode Enter the Diagnostics Test mode as described above in section 5 2 1 Push the alarm button within three seconds of the display of the first diagnostic mode screen to enter the Sensor Configuration mode A screen will briefly announce that the sensor configuration mode has been entered This screen will be followed by one showing the oxygen enable disable message 5 3 2 Enabling and disabling the oxygen and combustible gas LEL channels The oxygen and combustible LEL channels are dedicated that is no other sensor except an oxygen or combustible sensor may be inserted into the sockets where these sensors are located The only decision that may be made for these two channels is whether they are enabled turned on or disabled turned off Use the and keys to enable or disable the oxygen channel If the oxygen channel is disabled when the PhD is back in normal operation the gas reading screen will no longer show an oxygen indication To illustrate Gas reading
23. to change Recent court decisions have affected the enforcement of permissible exposure limits published or modified since the initial enactment of OSHA in 1971 The following table shows the OSHA permissible exposure limits as published in the 1989 edition of the Code of Federal Regulations 29 CFR 1910 1000 It is recommended that customers verify that the values given below are correct and current before using them to update their alarm set points Page 40 5 PhD2 default alarm settings The most conservative possible way to set alarms is the method used by Biosystems for the PhD default alarm settings The Ceiling alarm is set at the factory at the 8 hour TWA level when this is given With this setting it is unlikely that either the STEL or TWA alarm will ever be activated For other values contact Biosystems or your authorized distributor Biosystems PhD default alarm settings H2S SO2 Cl2 HCN NH3 25 PPM 25 PPM 25 PPM HCI 5 0 PPM 5 0 PPM 5 0 PPM NO2 1 0 PPM 1 0 PPM 1 0 PPM Oxygen O Low alarm High alarm 19 5 96 23 5 Combustible gas 10 LEL Page 41 Appendix C How to calibrate your PhD2 in contaminated air Calibration of the PhD is a two step process The first step is to expose the sensors to contaminate free air with an oxygen concentration of 20 996 and perform a fresh air calibration Unfortunately there are some locations which are never completely free of contaminants An exa
24. to each day s use It is not necessary to make a calibration adjustment if the readings are between 90 and 120 of the expected value As an example if a CO sensor is checked using a gas concentration of 50 PPM it is not necessary to perform a calibration unless the readings are either below 45 PPM or above 60 PPM Lengthening the Intervals between Verifications of Accuracy We are often asked whether there are any circumstances in which the period between accuracy checks may be lengthened Biosystems is not the only manufacturer to be asked this question One of the professional organizations to which Biosystems belongs is the Industrial Safety Equipment Association ISEA The Instrument Products group of this organization has been very active in developing a protocol to clarify the minimum conditions under which the interval between accuracy checks may be lengthened A number of leading gas detection equipment manufacturers have participated in the development of the ISEA guidelines concerning calibration frequency Biosystems procedures closely follow these guidelines If your operating procedures do not permit daily checking of the sensors Biosystems recommends the following procedure to establish a safe and prudent accuracy check schedule for your Biosystems instruments 1 During a period of initial use of at least 10 days in the intended atmosphere check the sensor response daily to be sure there is no
25. voltage potentiometer is located near the board s center and is the one and only pot on the back of the board 3 Remove the old toxic sensor in the Toxic 1 channel The following figure shows the sensor compartment with the Toxic 1 toxic sensor removed exposing the sensor pin connector sockets TOX 1 N N CENTER PIN SHORTING WIRE 4 Put a shorting wire across the two bias pin sockets as shown in the above figure A resister lead or paper clip may be used for this purpose 5 Using a voltmeter must be capable of reading 0 350 mVDC 1 mV resolution place the positive lead on the shorting wire and the negative lead in the center pin socket 6 Using a small slot head screwdriver adjust the bias voltage pot until the voltmeter reads the required value Remove the shorting wire Install the new sensor in the Toxic 1 socket If the new sensor is biased it should be allowed to stabilize for at least twenty four hours before calibration Unbiased sensors should be allowed to stabilize for at least one hour prior to calibration lt is not necessary for the instrument to be turned on during the stabilization period 8 9 Carefully making sure the water resistant gasket is correctly in place replace the five screws holding the two halves of the instrument case together 10 Turn the instrument on and enter the sensor configuration made as discussed in Section 5 3 1 Select the cor
26. volume in order to detect accurately A combustible sensor in a 100 percent pure combustible gas or vapor environment will produce a reading of zero percent LEL The amount of heat produced by the combustion of a particular gas on the active bead will reflect the Heat of Combustion for that gas Heats of combustion may vary from one combustible gas to another For this reason readings may vary between equivalent concentrations of different combustible gases A combustible gas and vapor reading instrument may be calibrated to any number of different gases or vapors If an instrument is only going to be used for a single type of gas over and over again it is usually best to calibrate the instrument to that particular hazard If the instrument is calibrated to a particular gas it will be accurate for that gas This is what is illustrated in the following chart 100 ao N CALIBRATION STANDARD RELATIVE LEL F METER RESPONSE 40 20r a 20 40 60 80 100 ACTUAL LEL CONCENTRATION Note that in a properly calibrated instrument a concentration of 50 percent LEL produces a meter response reading of 50 percent LEL The following graph illustrates what may be seen when a combustible reading instrument is used to monitor gases other than the one to which it was calibrated The chart shows the relative response curves of the instrument to several different gases OTHER GAsES
27. 2 3 Appendix B Appendix C Appendix D Appendix E Appendix F Appendix G Appendix H Problem Display is blank Problem No audible alarm Problem Function keypad Cal Alarm doesn t work Changing the PhD2 microprocessor PROM chip Replacing the internally housed sealed lead acid rechargeable battery Returning your PhD2 to Biosystems for service or repair 37 Toxic gas measurement Ceilings TWAs and STELs Ceiling level Time Weighted Average TWA Short Term Exposure Limits STEL How to determine where your alarms should be set How to calibrate your PhD2 in contaminated air Suggested Calibration Gases PhD2 Toxic Sensor Cross Sensitivity Data PhD2 sensor ranges Calibration Frequency Biosystems Standard Warranty Gas Detection Products Page 4 30 30 30 30 31 31 32 33 33 33 33 33 33 33 33 33 34 34 34 34 34 35 35 35 35 35 35 36 36 37 37 37 37 38 41 42 43 44 45 46 Introduction The PhD is a personal portable microprocessor controlled gas detector that can monitor up to four atmospheric hazards simultaneously The PhD measures oxygen combustible gas and up to two additional toxic gases The PhD uses a top mounted back lit Supertwist LCD liquid crystal display to simultaneously show readings of the gases being measured A loud audible alarm and individual alarm lights for each gas being monitored warn users of hazards The PhD offers a choice
28. 9 10 After completion of the zero adjustment the PhD automatically returns to the gas reading screen display 3 4 PhD2 span calibration Please note Calibration procedures for certain corrosive gas toxic sensors sulfur dioxide ammonia chlorine hydrogen cyanide and hydrogen chloride differ slightly from the standard procedures which follow Section 3 4 1 discusses special calibration procedures for these corrosive gas sensors In the span calibration procedure the PhD sensors are exposed to known concentration calibration gas Biosystems sells calibration kits and long lasting cylinders of check gas specifically developed for easy PhD calibration Customers are urged to use Sio iens calibration materials when calibrating their PhD The Biosystems calibration kit for the PhD Biosystems part number 1653 includes a foam lined carrying case with room for up to 3 cylinders of calibration gas a 1 0 liters per minute fixed flow rate regulator and hose Calibration gases must be ordered separately Please note The relative response of the combustible gas LEL sensor may vary from one combustible gas to another The best results are obtained when calibration is done using the same gas that is expected to be encountered while actually using the instrument if this is known Please see Appendix D for a list of suggested calibration gases The span calibration procedure may only be done while in the Technicia
29. Adjust mode Adjusting the sampling interval Baud rate Setting the date and time Page 3 17 17 17 17 18 18 18 19 19 20 20 21 22 22 22 24 24 24 24 24 25 25 25 25 25 26 26 27 27 28 28 28 28 29 29 29 29 29 29 30 30 6 2 5 6 3 6 3 1 6 3 2 6 3 4 6 3 5 6 3 6 Chapter 7 T 1 T 1 1 1 1 2 7 1 3 7 1 4 7 2 7 2 1 7 2 2 7 2 3 7 2 3 1 7 2 3 2 7 2 3 3 Exiting the Datalogging Adjust mode Downloading recorded data Entering the Record Keeping Data Transfer mode Downloading recorded data to the instrument screen Downloading recorded data to a computer Clearing data from PhD2 memory after downloading to P C Exiting the Record Keeping Data Transfer mode Trouble shooting and repair Changing PhD2 sensors Replacing toxic sensors Replacing combustible gas sensors Replacing oxygen sensors Adding removing or re configuring sensors Troubleshooting Re booting the microprocessor software Re initializing the PhD2 Specific problems Unit will not turn on Problem Unit will not turn off Problem LEL sensor readings unstable 7 2 3 4 Problem Toxic sensor readings unstable or numbers flash instead of remaining steady 7 2 3 5 Problem X appears under channel display for combustible gas 7 2 3 6 Problem Unstable oxygen readings 7 2 3 1 7 2 3 8 7 2 3 9 7 3 7 4 7 5 Appendices Appendix A 1
30. By date whichever comes first 90 days after activation or 90 days after the Must Be Activated By date whichever comes first 0 6 months of use 10096 credit 6 12 months of use 15 credit 12 18 months of use 50 credit 18 24 months of use 25 credit As long as the instrument is in service Mighty Tox Mighty Tox 2 Prorated credit is given towards repair or purchase of a new unit of the same type IQ Systems Series 3000 Airpanel Travelpanel ZoneGuard Gasv Chek1 and Gasv Chek4 Battery packs and chargers sampling pumps and other components which by their design are consumed or depleted during normal operation or which may require periodic replacement One year from the date of purchase One year from the date of purchase Sensor Warranty Periods Instrument s Sensor Type s Warranty Period PhD2 PhD Lite PhD Plus PhD i O2 LEL CO CO H2S amp Duo Tox i 2 Years Ultra Cannonball3 MultiVision _ All Other Sensors MultiPro Toxi Oxy Pro Toxi Toxi Oxy Plus Toxi Oxy Ultra LEL CO CO H2S Ex Chek All Other Sensors All Others All Sensors Damage to combustible gas sensors by acute or chronic exposure to known sensor poisons such as volatile lead aviation gasoline additive hydride gases such as phosphine and volatile silicone gases emitted from silicone caulks sealants silicone rubber molded products laboratory glassware greases spray lubricants heat transfer flui
31. N It is important to note that the correction factor for ethanol is different when the instrument is calibrated on propane In the case of a propane calibrated instrument instrument readings for ethanol will be high Given that the correction factor for ethanol in this case is 0 76 when the instrument reads 40 percent LEL the true concentration for ethanol is 30 4 percent LEL 40 LEL X 0 76 INSTRUMENT CORRECTION TRUE READING FACTOR CONCENTRATION When not sure what combustible gases might be encountered it is usually best to use a mixture of 1 1 propane in air 50 LEL combustible gas to calibrate the instrument Propane provides a sensor response which is more typical of the wide range of combustible gases and vapors than any other calibration mixture Use of other gases such as methane or hexane to calibrate the instrument should be reserved for situations where these are either the gases predominantly present or where the relative response to the calibration gas closely approximates that of the actual gas to be measured 2 30 496 LEL Toxic gas alarms The PhD has three separate alarm points for toxic gases Ceiling STEL and TWA OSHA has assigned some but not all toxic substances with a ceiling or Peak exposure level This is the highest concentration of a toxic substance to which an unprotected worker should ever be exposed even for a very short time Never enter an environment even momentarily when c
32. Operation Manual PhD2 Multi Gas Detector 651 South Main St Middletown CT 06457 860 344 1079 800 711 6776 FAX 860 344 1068 15NOV2004 Version 5 2 P N 13 027 ZNNARNING THE PhD2 PERSONAL PORTABLE GAS DETECTOR HAS BEEN DESIGNED FOR THE DETECTION OF OXYGEN DEFICIENCIES FLAMMABLE GAS AND TOXIC VAPOR ACCUMULATIONS IN ORDER TO ASSURE THAT THE USER IS PROPERLY WARNED OF POTENTIALLY DANGEROUS ATMOSPHERIC CONDITIONS IT IS ESSENTIAL THAT THE INSTRUCTIONS IN THIS MANUAL BE READ FULLY UNDERSTOOD AND FOLLOWED AVERTISSEMENT LIRE ATTENTIVEMENT LES INSTRUCTIONS AVANT DE METTRE EN MARCHE PhD Operation Manual Copyright 2004 by Biosystems LLC Middletown CT 06457 All rights reserved No page or part of this operation manual may be reproduced in any form without written permission of the copyright owner shown above Page 1 Table of Contents Introduction 5 Signal Words reru n nen n nnn LLL e LLLLLLLLLD WARNINGS AND CAUTIONS LL Lr LL LL rr LLL a Chapter 1 PhD2 Description 1 1 PhD2 capabilities 1 1 1 Methods of sampling 1 1 2 Multi sensor capability 1 1 3 Calibration 1 1 4 Alarm logic 1 1 5 Atmospheric hazard alarms 1 1 6 Low battery alarms 1 1 7 Other alarms and special microprocessor features 1 1 8 Classification for intrinsic safety 1 1
33. Press the Cal button to re initialize the detector A 4 screen will indicate that re initialization is in progress This screen will be followed by another indicating successful completion The PhD will then turn itself off Remember to verify that sensor choices alarm settings datalogging interval and other configuration choices are correct The PhD must be recalibrated before being returned to service 5 Pressing the MODE button cancels the re initialization procedure and returns the instrument to the Diagnostic Mode screen showing LEL and oxygen diagnostic counts Page 34 7 2 3 Specific problems 7 2 3 1 Possible causes Unit will not turn on Battery discharged microprocessor software malfunction Solution s Take the instrument to a non hazardous location Plug the PhD into the battery charger for several minutes With the instrument still connected to the battery charger attempt to turn the detector on If this works the battery needs to be recharged or replaced If the instrument still fails to turn on re boot the microprocessor using the procedures discussed in Section 7 2 1 If the instrument still fails to turn on return to factory for repair 7 2 3 2 Possible causes Problem Unit will not turn off Software malfunction low or bad battery faulty on off mode switch Solution s Hold MODE button down for thirty seconds This should turn the instrument off Take the i
34. TELs Many toxic substances are commonly encountered in industry The presence of toxic substances may be due to materials being stored or used the work being performed or may be generated by natural processes Exposure to toxic substances can produce disease bodily injury or death in unprotected workers It is important to determine the amounts of any toxic materials potentially present in the workplace The amounts of toxic materials potentially present will affect the procedures and personal protective equipment which must be used The safest course of action is to eliminate or permanently control hazards through engineering workplace controls ventilation or other safety procedures Unprotected workers may not be exposed to levels of toxic contaminants which exceed Permissible Exposure Limit PEL concentrations Ongoing monitoring is necessary to insure that exposure levels have not changed in a way that requires the use of different or more rigorous procedures or equipment Airborne toxic substances are typically classified on the basis of their ability to produce physiological effects on exposed workers Toxic substances tend to produce symptoms in two time frames Higher levels of exposure tend to produce immediate acute effects while lower levels of long term chronic exposure may not produce physiological symptoms for years Hydrogen sulfide H2S is a good example of an acutely toxic substance which is immediately lethal a
35. UTION The Cal button must be held down until the screen indicates that span calibration has been successfully completed If the button is released before this message is displayed span values will not be updated and remain unchanged from the last time a span calibration was successfully completed 3 4 1 Calibration procedures for sulfur dioxide ammonia chlorine hydrogen cyanide and hydrogen chloride corrosive gas sensors Highly reactive or corrosive gases such as sulfur dioxide ammonia chlorine hydrogen cyanide and hydrogen chloride tend to react quickly with or be absorbed by other substances These reactions can occur so quickly that there may not be adequate time for the gases to diffuse through the moisture barrier in the standard PhD sensor compartment cover before they are gone ZAWARNING The standard sensor compartment cover which includes a moisture barrier may not be used as long as a corrosive gas sensor is installed When the sensors installed in your PhD include a corrosive gas sensor a special sensor compartment cover part number 35 692 must also be installed Note The sensor compartment cover used when a sulfur dioxide chlorine ammonia hydrogen cyanide hydrogen chloride or TOX 1 sensor is installed does not include a moisture barrier filter Avoid direct exposure to liquids to reduce the chance for damage due to leakage Sulfur dioxide ammonia chlorine hydrogen cyanide and
36. Z HORS GAMME DE D TECTION QUI PEUT TRE DANGEREUSE Page 6 Chapter 1 PhD2 Description Different measurement units are used depending on the gas being measured Common examples include 2 Igi Concentration of Is indicated in 1 1 Phb capabilities Oxygen O9 Percentage of air by volume The PhD is a gas detector with numerous features that Percentage of the lower can be modified to meet user requirements This chapter explosive limit LEL discusses some of those features Table 1 1 1 1 Methods of sampling The PhD2 may be used as either a Diffusion or Sample Draw type monitoring device Sensor configuration procedures are discussed in greater detail in section 5 3 In normal operation the PhD detector is worn on the belt used with its shoulder strap or held by hand Once 1 1 3 Calibration turned on the PhD monitors continuously The atmosphere being measured gets to the sensors by diffusing through vents in the sensor compartment cover Normal air movements are enough to carry the sample to the sensors The sensors react immediately to changes ZAWARNING The accuracy of the PhD2 should in the concentrations of the gases being measured This be checked periodically with known concentration type of diffusion operation monitors only the calibration gas Failure to check accuracy can lead atmosphere that immediately surrounds the detector to inaccurate and potentially dangerous readings The PhD detector has been design
37. a corrosive gas sensor a special sensor compartment cover part number 35 692 must also be installed Please be advised that the sensor compartment cover used when a chlorine ammonia hydrogen cyanide hydrogen chloride or TOX 1 sensor is installed does not include a moisture barrier filter Avoid direct exposure to liquids to reduce the chance for damage due to leakage The standard sensor compartment cover which includes a moisture barrier may not be used as long as a corrosive gas sensor is installed Page 26 Figure 5 1 Placement of PhD sensors in the sensor compartment If a sensor is not installed in Toxic 1 or Toxic 2 or if a toxic sensor is to be permanently removed use the and keys to choose the Disable option from the toxic sensor menu list 5 3 3 1 Resetting the toxic sensor bias voltage Most of the toxic sensors available for use in the PhD are unbiased that is they do not require a constant voltage applied to them while the instrument is turned off Four currently available toxic sensors do require a bias voltage The bias must be set at the time they are installed The four sensors are nitric oxide NO hydrogen chloride HCl ammonia NH3 and the TOX 1 broad range electrochemical sensor When a toxic sensor channel is being reconfigured from one unbiased sensor type to another unbiased sensor it is not necessary to adjust the bias voltage The bias voltage for all unbiased toxic
38. adings to stabilize In the case of some corrosive gases stabilization may require three to four minutes When the readings stabilize use the and keys to raise or lower the readings to match the concentration printed on the calibration cylinder label When the span calibration has been completed for all channels press and hold the Cal button until an information screen indicates that calibration is complete Chapter 4 Setting alarm levels PhD alarms are user adjustable and may be set anywhere within the range of the sensor channel When an alarm set point is exceeded a loud audible alarm sounds and an individual bright red LED alarm light for each affected sensor blinks PhD alarms are normally self resetting that is as soon as readings drop below the alarm set point the alarm ceases lt is possible if desired to set PhD alarms so that they latch In the latched condition once an alarm occurs both visual and audible alarms continue to sound even after the atmospheric hazard has cleared The instrument must be manually reset by pressing the MODE button Pressing the MODE button silences the alarms and restores normal operation Procedures for latching PhD alarms are given in Section 5 3 7 4 1 Alarm adjustment sequence It is necessary to be in the Alarm Adjust mode before it is possible to change alarm settings Once in this mode it is possible to adjust any of the oxygen LEL or toxic
39. age being displayed the instrument will not turn off After the button is released the LCD display will display the message Begin SHUT DOWN Please wait During the shut down sequence the PhD is checking that all data is properly stored in memory The shut down sequence is complete when the meter display blanks out in about ten seconds 2 2 Operating modes The PhD offers a choice of three modes of operation Text Only Basic and Technician Which mode is selected is a function of how much information is required the skill level of the user and the nature of the job Whatever operating mode is selected the PhD automatically remembers logs gas readings as well as other important information such as turn on turn off times battery condition and whenever the instrument is calibrated 2 2 1 Text Only mode The simplest mode of operation is the Text Only mode In this mode during normal operation the LCD screen does not display numerical readings only the indication OK If an alarm condition occurs that is when one of the sensor readings exceeds a pre set alarm level the indication changes from OK to the numerical value the LED alarm light flashes and the audible alarm sounds PhD alarms are normally self resetting When readings drop back below the pre set alarm levels the screen reverts back to the OK indication and visual and audible alarms cease In the Text Only mode only one pu
40. alizing the PhD2 During production PhD detectors are initially set up or programmed with a default or standard configuration This standard configuration includes oxygen combustible gas carbon monoxide and hydrogen sulfide for the sensors installed The alarms are set to the default values for these hazards and a datalogging interval of one minute is specified The default configuration may be restored at any time by using the following procedure CAUTION Reinitialization destroys all logged data currently in the instrument memory Re initialization will cause the current instrument configuration to revert to the default settings Span calibration values currently in memory will be lost Custom alarm settings and other configuration values must be re entered and the instrument must be re calibrated before being put back into service To re initialize the PhD2 1 Enter the Diagnostics Test mode by turning the detector on while simultaneously holding down the and buttons The Diagnostic Test screen will briefly appear This screen will be followed by another which shows the release date of the software version currently installed in the PhD and the instrument identification number 2 Press the Cal button within three seconds to begin the re initialization sequence 3 The Re Initialization Set up screen will briefly be displayed This will be followed by the Initialization Adjust message
41. ally generate and print reports tables and graphs of time history exposure data It is also possible to export records to other software applications in the form of ASCII Lotus compatible or comma delimited database files Another option is to simply retain downloaded records of your gas detection monitoring program Note The material in Chapter 6 is primarily designed to acquaint our customers with the manual PhD2 setup and download procedures Full instruction for use of the Datalink and Gas Detection Database kit are contained in the PhD Datalink manual Please consult these materials for further guidance 6 2 Adjusting record keeping parameters It is possible to adjust or customize the way the PhD logs data in a number of different ways Options include extended recording time tagging the exposure data with time and date information or assigning a location number 6 2 1 Entering the Datalogging Adjust mode Turn on the PhD while holding down the button The unit must be in the Technician mode prior to being turned on The Datalog Adjust screen will briefly appear The Datalog Adjust screen is followed by the sample interval adjust screen 6 2 2 Adjusting the sampling interval When the PhD is turned on it immediately begins to monitor calculate and log exposure levels for the atmospheric hazards it is set up to detect For the purposes of developing a time history chart or graph this continuous data
42. ations including surges and lightning strikes incorrect voltage settings incorrect batteries or repair procedures not made in accordance with the Instrument s Reference Manual are not covered by the Biosystems standard warranty The obligation of Biosystems under this warranty is limited to the repair or replacement of components deemed by the Biosystems Instrument Service Department to have been defective under the scope of this standard warranty To receive consideration for warranty repair or replacement procedures products must be returned with transportation and shipping charges prepaid to Biosystems at its manufacturing location in Middletown Connecticut or to a Biosystems Authorized Warranty Service Center It is necessary to obtain a return authorization number from Biosystems prior to shipment THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE BIOSYSTEMS WILL NOT BE LIABLE FOR LOSS OR DAMAGE OF ANY KIND CONNECTED TO THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY Instrument amp Accessory Warranty Periods Product s PhD2 PhD Lite PhD Plus PhD Ultra Cannonball3 MultiVision Ex Chek Toxi Toxi Oxy Plus Toxi Oxy Ultra Toxi Oxy Pro MultiPro 2 years from date of purchase Toxi Oxy Limited 2 years after activation or 2 years after the Must Be Activated
43. ave a cumulative loss of sensitivity as a function of high exposure to the contaminant they were designed to measure Cross sensitivity of PhD toxic sensors to common interfering gases is listed in Appendix E 3 3 Fresh air zero calibration The fresh air zero must be done in fresh uncontaminated air In this procedure the instrument automatically adjusts its oxygen combustible gas and toxic gas readings to match the concentrations present in fresh air 20 9 percent O2 0 0 percent LEL 0 0 PPM toxic gas Since fresh air contains 20 9 percent oxygen this is the only calibration needed for the oxygen sensor Toxic and combustible gas sensors must also undergo span calibration to insure accuracy If the PhD2 cannot be taken to an area where the air is fresh or if it is not certain whether or not the air is uncontaminated special procedures are required These procedures are discussed at greater length in Appendix C 3 3 1 Fresh air zero calibration sequence The fresh air zero procedure may only be done while the instrument is being operated in either the Technician or Basic operating mode Version 4 7 and higher PhD micro processor software allows the instrument to be fresh air zeroed directly through the MODE button using the procedures discussed in Section 3 3 1 1 Version 4 6 and lower instruments may only be fresh air zeroed using the hidden push buttons and procedures discussed in Section 3 3 1 2 Version
44. ay be necessary to remove the sensor compartment cover to verify sensor placement If two toxic sensors have been installed the meter display will list the sensor installed in Toxic 1 first Figure 3 4 1 Placement of PhD sensors in the sensor compartment Hold the adaptor directly over the location of the correct sensor 4 5 Open the calibration gas regulator valve to obtain a flow of approximately 1 0 liters per minute Wait for the readings to stabilize In the case of some corrosive gases stabilization may require three to four minutes 6 Note the final response 7 Readings which are more than 10 percent higher or any amount lower than expected indicate the instrument must be span adjusted before further use 3 4 1 2 Corrosive gas sensor span adjust procedures Note Removal of the sensor compartment cover aids accurate placement of the calibration adaptor For maximum accuracy it is best to remove the sensor compartment cover before corrosive gas sensor span adjustment 1 Remove sensor compartment cover Page 21 2 3 4 5 6 7 8 Enter the Span Calibration mode as discussed in Section 3 4 above Connect the regulator adaptor and length of FEP lined tubing to the cylinder of calibration gas Hold the adaptor directly over the correct toxic sensor Open the calibration gas regulator valve to obtain a flow of approximately 1 0 liters per minute Wait for the re
45. buttons to change operating modes Each time the operating mode is changed the display screen will briefly indicate which operating mode has been selected Shifting modes or otherwise reprogramming the instrument should only be done by employees who are authorized to do so 2 3 Batteries 2 3 1 PhD battery options Two types of rechargeable batteries are available for use in the PhD2 design The type of battery selected must be specified at the time of purchase 2 3 1 1 NiCad A removable NiCad battery pack is available as an option with the PhD2 design The NiCad battery pack is secured by two screws located on the bottom of the PhD lt case and may be removed or replaced without disassembly of the instrument The NiCad battery pack may be safely removed and replaced even while the PhD is being used in hazardous locations CAUTION Make sure the PhD is turned off before removing the NiCad pack Removing the NiCad pack before the instrument has properly stored the current data during shut down may result in the loss of data from the most recent monitoring session CAUTION If the NiCad battery pack is removed it must be replaced within one hour to avoid the potential loss of recorded gas measurement data Calibration and configuration data are stored in a non volatile permanent memory and are not subject to loss due to battery removal CAUTION Care should be taken not to over tighten the screws which secure the NiCad batter
46. ciencies and one for high concentrations associated with oxygen enrichment Three alarm set points have been provided for each toxic gas monitored TWA Time Weighted Average STEL Short Term Exposure Limit and Ceiling Appendices A and B discuss choosing alarm levels The procedures for adjusting alarm set points are given in Chapter 4 1 1 6 Low battery alarms Alarms will be activated whenever battery voltage is too low to allow the safe operation of the instrument When the battery voltage is reduced to 5 65 Volts an audible alarm sounds and the display screen indicates a low battery condition exists At this stage the low battery alarms may be silenced for a fifteen minute period by pressing the large black Mode push button The alarm will continue to sound every fifteen minutes until the voltage reaches 5 55 Volts When the battery voltage is reduced to 5 55 Volts the battery alarm will sound every 30 seconds At this point it is no longer safe to continue to use the instrument until the battery has been recharged and it is necessary to leave any hazardous area in which the instrument is being used immediately When the battery voltage is reduced to 5 45 Volts the PhD will display a Dead Batt message to warn the user of imminent shut down The instrument will then automatically turn itself off protecting the battery from deep discharge After any low battery alarm the PhD battery must immediately be recharged
47. clean and dry before attaching the regulator to the cylinder of gas Introduction of contaminants through the regulator fittings may alter or degrade the concentration of the gas contained in the cylinder and may lead to inaccurate and potentially dangerous gas readings 9 Connect the flexible hose between the calibration adapter and the regulator on the calibration gas cylinder 10 Open the calibration gas regulator valve fully to obtain a flow of approximately 1 0 liters per minute 11 When the readings stabilize use the and keys to raise or lower the readings to match the concentration printed on the calibration cylinder label 12 When the span calibration for a particular sensor is completed advance to the next channel by pushing the Cal button 13 Make sure the correct cylinder of gas is attached before attempting to adjust the span If the concentration of gas reaching the sensor is too low to allow the instrument to be adjusted or if the wrong type of gas is applied to the sensor being adjusted a screen will be displayed indicating that the span gas concentration is too low Verify that the flow rate of the regulator is 1 0 lom Replace the cylinder or choose the correct sensor and continue 14 When span calibration has been completed for all channels press and hold the Cal button down until the information screen indicates that calibration is complete The PhD will then turn itself off CA
48. creen returning to the OK message Pressing the Alarm button turns the Text Only alarm latch ON or OFF In general after clearing an alarm most users prefer to see the OK indicator displayed rather than a numerical value This will be the case when the OK Latch indicator is set to OFF 5 3 7 Pressing the Cal button again advances to the Alarm latch screen Alarm latch command PhD alarms are normally self resetting that is as soon as readings drop below the alarm set point the alarm ceases It is possible if desired to set PhD alarms so that they latch In the latched condition once an alarm occurs both visual and audible alarms continue to sound even after the atmospheric hazard has cleared The instrument must be manually reset by pressing the MODE button Pressing the MODE button silences the alarms and restores normal operation Page 28 5 3 8 Security beep Pressing the Cal button again advances to the Security Beep screen The security beep feature allows the PhD to be programmed to emit an audible alarm beep on a regular basis while the instrument is in operation This periodic beep serves as a reminder that the instrument is on Use the key to turn the security beep on Once the security beep is turned on the screen will show an additional indicator message 00 00 00 standing for the hours minutes and seconds between beeps Use the and keys to set the
49. ds waxes amp polishing compounds neat or spray aerosols mold release agents for plastics injection molding operations waterproofing formulations vinyl amp leather preservatives and hand lotions which may contain ingredients listed as cyclomethicone dimethicone and polymethicone at the discretion of Biosystems Instrument Service department void Biosystems Standard Warranty as it applies to the replacement of combustible gas sensors Page 46
50. dures for specific toxic gases Please note Biosystems EZ Cal multi component calibration gas mixtures are available for use with many common PhD detector configurations The calibration gas supplied in Confined Space Kits is normally an all in one mixture when one is available If an all in one mixture is not desired please order the PhD and calibration materials separately Gas Part Number component gas CO 5096 LEL in air methane in air component gas CO 50 LEL in air propane in air component gas CO PPM methane 5096 H5S methane in air LEL in air component gas CO PPM propane 50 H5S propane in air LEL in air of methane or natural gas only combustible gas monitoring MESS S c S Carbon monoxide 9033 50 PPM in air CO Hydrogen sulfide 9034 25 PPM in nitrogen H2S a a n Hexane CeH414 9038 0 3 25 LEL in air Sulfur dioxide SO5 9037 10 PPM in nitrogen Zero air 20 9 oxygen in Use for fresh air calibration in nitrogen contaminated areas Ammonia NH3 Chlorine Clo p in ni a Hydrogen cyanide 9054 10 PPM in nitrogen HCN in ni aaa Nitric oxide NO 9055 30 PPM in nitrogen Nitrogen dioxide 9056 5 PPM in nitrogen NO5 Page 42 Appendix E PhD2 Toxic Sensor Cross Sensitivity Data The table below lists the cross sensitivity of electrochemical toxic sensors used in Biosystems portable gas detectors to gases other than their target gas Depending on
51. e of these push buttons in span adjustment microprocessor circuitry eliminates the need for manual procedures is reserved for authorized personnel switch setting and other laborious set up procedures a is still necessary to verify the accuracy of the PhD by calibration with known concentration test gas Chapter 3 whenever a change is made to the sensors installed in the instrument Calibration procedures are discussed in detail in 1 1 4 Alarm logic PhD2 gas alarms are user adjustable and may be set anywhere within the range of the sensor channel When an alarm set point is exceeded a loud 100 dBA at six inches audible alarm sounds and an individual bright red LED alarm light for each affected sensor flashes The PhD2 design uses highly specific electrochemical toxic sensors that have been designed to minimize the effects of common interfering gases These sensors provide accurate dependable readings for many common toxic gases Currently available toxic sensors for use in the PhD include hydrogen sulfide H2S carbon PhD2 gas alarms are normally of the self resetting type monoxide CO ammonia NH3 chlorine CI2 sulfur When readings drop back below the pre set alarm levels dioxide SO2 nitric oxide NO nitrogen dioxide NO2 the instrument reverts back to normal operation and the hydrogen chloride HCI and hydrogen cyanide HCN visual and audible alarms cease In addition to sensors designed to measure specific
52. ed for easy calibration without the use of manually adjusted calibration pots IL Is possible Me PhD to sample Temor locations Calibration is a two step procedure In the first step the by using a sample draw kit Two sample drawing kits are PhD is taken to an area where the atmosphere is fresh available In each case the sample is drawn in through a and a zero adjustment is made automatically on probe assembly and sucked through a length of hose demand by pressing a button back to the instrument One type of kit uses a hand operated squeeze bulb to draw the sample through the The second step of the calibration procedure is the hose the other uses a battery operated continuous sensor response or span calibration In this step the mechanical pump A hand aspirated sample draw kit is accuracy of the PhD sensors is established by exposing included as an accessory with every PhD Use of the them to known concentration calibration gas and noting sample draw kits is covered in section 2 4 the response If there is a deviation from the expected I 2 response the instrument may be adjusted immediately by 1 1 2 Multi sensor capability pressing buttons on the instrument key pad or the instrument may be taken out of service and returned to 2 i i The PhD can be configured to simultaneously monitor another location for adjustment one two three or four gases Sensors can be added deleted changed or replaced in the field The PhD2 Us
53. een Although it is not necessary to make use of information being recorded and stored by the PhD2 it is there in the event it is needed 6 1 1 Optional Datalink and Gas Detection Database Software kit An optional Datalink and Gas Detection Database software kit is available for use with the PhD The kit allows your PhD and your computer to communicate with each other The software serves two basic functions getting stored information out of the instrument and into your computer and using files stored in your computer to setup or program your PhD2 It is important to note that it is not necessary to use the Datalink software to program your PhD All configuration and setup options may be programmed directly by using the built in buttons on the instrument keypad On the other hand the datalink software has been designed to make programming downloading and data analysis aS easy as pushing a button The software allows optional instrument setups to be created by filling out forms right on the computer screen Most functions such as downloading stored information from the instrument to your PC or uploading configuration setup files from your PC to the instrument are automatic The software is designed to help you along Once information has been downloaded to the computer it may be used for a variety of purposes Data may be displayed and reviewed in detail through the computer monitor screen or used to automatic
54. esigned to do Always follow the guidelines provided by the manufacturer for any gas detection equipment you use If there is any doubt regarding your gas detectors accuracy do an accuracy check All it takes is a few moments to verify whether or not your instruments are safe to use One Button Auto Calibration While it is only necessary to do a bump test to ensure that the sensors are working properly all current Biosystems gas detectors offer a one button auto calibration feature This feature allows you to calibrate a Biosystems gas detector in about the same time as it takes to complete a bump test The use of automatic bump test and calibration stations can further simplify the tasks while automatically maintaining records Don t take a chance with your life Verify accuracy frequently Please read also Biosystems application note AN20010808 Use of equivalent calibration gas mixtures This application note provides procedures to ensure safe calibration of LEL sensors that are subject to silicone poisoning Page 45 Appendix H Biosystems Standard Warranty Gas Detection Products General Biosystems LLC hereafter Biosystems warrants gas detectors sensors and accessories manufactured and sold by Biosystems to be free from defects in materials and workmanship for the periods listed in the tables below Damages to any Biosystems products that result from abuse alteration power fluctu
55. ftware PROM Figure 7 3 PhD2 main circuit board showing placement of the software PROM Note If you are upgrading from any Version 3 series software to any Version 4 series software a complete initial setup of the PhD will also be required Certain hardware modifications may also be necessary Please contact Biosystems for additional information 7 4 Replacing the internally housed sealed lead acid rechargeable battery Note Replacement of the sealed lead acid battery pack requires opening the instrument and replacing an internally housed component This procedure should not be done by unauthorized persons To replace the PhD sealed lead acid battery 1 Download any recorded data in the instrument memory prior to replacing the battery Disconnection of the battery will result in the loss of recorded data 2 Turn the PhD off 3 Remove the five screws holding the instrument case together and separate the two halves of the case 4 Note the position of the sealed lead acid battery pack and the wires connecting the battery with the main circuit board 5 Carefully pull the battery free of the case 6 Disconnect the old battery by gently pulling apart the two halves of the white nylon four pin connector 7 Connect the new battery and carefully replace in the instrument case Do not force Make sure the wires connecting the main circuit board and battery pack are not crimped they should be tucked u
56. gas alarm set points In many cases it is possible to comply with OSHA guidelines while using higher alarm points than those used by Biosystems It is important to note that the default alarm point settings used in the PhD design are very conservative in order to provide maximum worker safety PhD2 default alarm setting are listed in Section 4 of Appendix B To enter the alarm adjust mode it is necessary to do the following 1 Turn the instrument on and remove it from its vinyl carrying case 2 Remove the keypad cover exposing the four mini push buttons 3 Verify that the instrument is in the Technician operating mode Switch modes if necessary by simultaneously holding down the and keys Each time that the operating mode is changed the meter screen will briefly indicate the current operating mode 4 Turn the instrument off by pressing the MODE button for three full seconds until the release button message appears in the screen 5 With the unit turned off press and hold down the Alarm button 6 While holding down the Alarm button press the MODE button to turn the PhD back on The Alarm Adjust message will appear briefly on the screen This message is followed by a screen showing the first alarm point to be adjusted 7 Pressing the alarm button again will advance the display to the next available alarm adjustment option Pressing the MODE button at any time cancels the alarm adjustment
57. h the Biosystems Personal Computer PC Based Gas Detector Database software Although downloading the recorded data to a computer file offers the most complete way to examine the data it is also possible to review data directly from the PhD meter display It is not necessary to interface the instrument with a computer in order to review the data through the meter Reviewing recorded data directly through the instrument display screen allows the user to answer two very important questions 1 Were my workers using their instruments 2 Did the atmosphere have any problems 6 3 1 Entering the Record Keeping Data Transfer mode The Record CDI Data Transfer mode is entered by turning the PhD on while holding down the key The unit must be in the Technician mode prior to being turned on See Section 2 2 4 The Record Keeping Data Transfer screen will briefly appear 6 3 2 Downloading recorded data to the instrument screen The Record Keeping Data Transfer screen is followed by another screen which is used to choose whether the data is to be downloaded directly to the PhD screen or to be downloaded via the RS 232 port to a computer Pressing tells the PhD to download to the instrument screen The display briefly shows the following screen This will be followed by a screen which shows the most recent monitoring session The most recent completed session is always session number 0 As an example The numbe
58. hD detectors 5 2 3 Exiting the Diagnostics Test mode The Diagnostics Test mode is exited by turning the PhD2 off This is done in the usual manner by holding down the MODE button for 3 seconds 5 3 Sensor Configuration mode The PhD2 can be configured as a one two three or four gas monitor Changes in the number and types of sensors are made while in the Sensor Configuration mode Sensors can be added deleted changed or replaced in the field The PhD2 microprocessor circuitry eliminates the need for manual switch setting and other laborious set up procedures It is still necessary however to verify the accuracy of the PhD2 by calibration with known concentration test gas whenever a change is made to the sensors installed in the instrument Changes made while in the Sensor Configuration mode will trigger a Needs Cal message the next time the instrument is turned on while in a normal operation mode The LCD rotates between the Needs Cal message and each type of sensor the instrument understands to be currently installed This message will continue to be displayed any time the instrument is turned on in a normal operation mode until all the sensors have been successfully calibrated Pressing the MODE button to acknowledge the Needs Cal alarm silences the alarms and allows the normal operation of the instrument Each time the instrument is turned on the Needs Cal alarms will be activated until all sensors have been
59. he PhD with a computer it is necessary to purchase a Biosystems Computer Link Kit Biosystems part number 1698 The Biosystems link kit includes database software interface cable and instructions for use Make sure the PhD is turned off Connect the computer interface cable between the dual purpose battery charger RS232 connector located on the side of the PhD2 case and COM port 1 of your computer Note It is important that the instrument is turned off before being connected to the interface cable in order to avoid potential damage or data loss due to static electrical discharge Enter the Record Keeping Data Transfer mode by turning the PhD on while holding down the The unit must be in the Technician mode prior to being turned on The Record Keeping Data Transfer screen will briefly appear The record Keeping Data Transfer screen is followed by another screen used to choose whether the data is to be downloaded directly to the PhD screen or to be downloaded via the RS 232 port to a computer Press the button to download data through the RS 232 port This screen will be followed by the Data Transfer screen Pressing the MODE button initiates data downloading Pressing the MODE button at any time during the downloading process terminates the transmission When downloading has been completed the screen will display the message 6 3 5 Clearing data from PhD2 memory after downloading to P C T
60. he response ratios may also shift over the life of a particular sensor It is also very important to understand that if an error is made in determining the specific kind of gas present and the wrong correction factor is used the accuracy of the calculation may be significantly affected The best results are obtained when calibration is done using the same gas that is expected to be encountered while actually using the instrument 3 Correction factors for PhD2 combustible gas Sensors Correction factor when instrument is calibrated on Hydrogen n qr Correction factor when instrument is calibrated on Propane Combustible Gas Vapor 1 1 1 1 2 2 al Ol Methanol 065 Ethanol L8 LLL Isopropyl 1 Alcohol L 18 E 17 o5 QOiNlomo olo 1 olo Ketone Ethyl Acetate 12 Gasoline Unleaded Page 39 As an illustration consider a PhD2 calibrated on methane which is then used to monitor ethanol When calibrated to methane the instrument is actually less responsive to ethanol than to methane so the readings will be low Multiplying the instrument reading by the correction factor for ethanol will produce the true concentration Given that the correction factor for ethanol is 1 2 if the instrument reading is 40 percent LEL then the true concentration is seen to be 48 percent LEL 40 LEL X 1 2 4896 LEL INSTRUMENT CORRECTION TRUE READING FACTOR CONCENTRATIO
61. hould be checked periodically with known concentration calibration gas Failure to check accuracy can lead to inaccurate and potentially dangerous readings For a detailed discussion of calibration frequency see Appendix G Verification of accuracy is a two step procedure In the first step the PhD is taken to an area where the atmosphere is fresh and the readings are checked If the readings differ from those expected in fresh air a Zero adjustment must be made The second step is to make sure the sensors are accurate by exposing them to known concentration test gas and noting the response This is known as a functional or bump test If the readings during the bump test are considered accurate the instrument may be used without further adjustment Span adjustments are made by pressing buttons on the instrument keypad Use of the push buttons in span adjustment procedures is reserved for authorized personnel 3 1 Functional bump test A simple functional bump test is all that is needed to very accuracy To do a functional bump test turn the PhD on and wait at least three minutes to allow the readings to fully stabilize Make sure the instrument is located in fresh air Check to see that the readings match the concentrations present in fresh air 20 9 O2 0 LEL O PPM toxic If necessary fresh air zero the instrument using the procedures discussed in Section 3 3 of this manual Slip on the calibration adaptor as di
62. hydrogen chloride calibration kits include a special Teflon calibration adaptor and a length of FEP fluoro polymer lined tubing used to connect the adaptor to the cylinder of calibration gas The standard sample draw calibration adapter used during non corrosive span adjustment procedures flows gas to all sensors simultaneously The Teflon calibration adaptor is a small white cylindrical cup designed to flow gas to a single sensor at a time 3 4 1 1 Corrosive gas sensor functional bump test It is possible to do a functional bump test to verify the accuracy of a corrosive gas sensor The sensor compartment cover may be left in place for this procedure 1 Attach the regulator to the calibration gas cylinder Make sure the regulator cylinder seating surfaces and threads are clean and dry It is best to leave the regulator open and flowing gas when attaching it to Page 20 the cylinder Turn the regulator off after it has been screwed into place in the cylinder Note Biosystems recommends the use of a special corrosion resistant regulator part number 12 025 for ammonia and hydrogen chloride calibrations Biosystems standard regulator part number 12 023 may be used for other corrosive gases 2 Connect the Teflon adaptor and length of FEP lined tubing to the cylinder of calibration gas 3 Note the position in which the corrosive gas sensor has been installed either Toxic 1 or Toxic 2 Note It m
63. ing case and slip the sample draw cup over the end of the instrument 3 Cover the end of the sample draw probe assembly with a finger and squeeze the aspirator bulb If there are no leaks in the sample draw kit components the bulb should stay deflated for a few seconds 4 Insert the end of the sample probe into the location to be sampled 5 Squeeze the aspirator bulb several times to draw air from the remote location to the sensor compartment Allow one squeeze of the bulb for every three feet of sampling hose 6 Note the gas measurement readings ZAWARNING Hand aspirated remote sampling only provides continuous gas readings for the area in which the probe is located while the bulb is being continuously squeezed Each time a reading is desired it is necessary to squeeze the bulb a sufficient number of times to bring a fresh sample to the sensor compartment 2 4 2 Using the battery operated slip on sample draw pump Use of the slip on battery operated pump allows the PhD2 to continuously monitor remote locations CAUTION Never perform remote sampling with the PhD2 without the sample probe assembly The sample probe handle contains replaceable filters designed to block moisture and remove particulate contaminants If the pump is operated without the probe assembly in place contaminants may cause damage to the pump sensors and internal components of the PhD2 The sample draw pump includes a unique pressure sens
64. ing down the MODE button until the instrument turns off then taking the instrument to a location where the air is fresh and turning the instrument back on Normal combustible sensor operation is resumed at the time the instrument is reset CAUTION Never reset the instrument by fresh air zeroing Attempting to reset the instrument by doing a fresh air zero adjustment will result in inaccurate readings In the event of a protective over limit alarm latch condition the instrument must be turned off taken to an area where the air is fresh and turned back on to resume normal operation Verify accuracy by exposing the sensor to known concentration test gas before further use Z WARNING The combustible sensor used in the PhD design requires the presence of oxygen in order to detect combustible gas The accuracy of the combustible sensor may be affected if the instrument is used in oxygen deficient atmospheres ZAWARNING A rapid up scale reading followed by a declining or erratic reading may indicate a hazardous combustible gas concentration that exceeds the PhD5 s zero to 100 percent LEL detection range Avertissement Toute lecture rapide et positive suivie d une baisse subite au erratique de la valeur peut indiquer une concentration de gaz hors gamme de d tection qui peut tre dangereuse 3 2 3 Effects of contaminants on toxic gas sensors Some toxic sensors are sensitive to more than one contaminant Others may h
65. ing projects If datalogging is not desired an interval setting of 00 00 Will deactivate the datalogger When finished adjusting the sampling interval press the Cal button to move on to the next screen 6 2 3 Baud rate Baud rates determine the speed at which data is transferred via the RS 232 port to a computer The PhD2 comes from the factory with the baud rate set at 9600 This is the appropriate setting for interfacing with most personal computers Press the Cal button to move on to the next screen 6 2 4 Setting the date and time This screen is used to set or adjust the PhD2 internal real time clock and calendar date A cursor will highlight the value to be adjusted Pressing the and buttons will change the value Pressing the Alarm button will advance the cursor to the next unit Check the settings by pressing the Cal button Quit and save the new settings by pressing and holding the Cal button Pressing the MODE button at any point in the procedure will return the settings to their former levels 6 2 5 Exiting the Datalogging Adjust mode When the PhD is properly configured press and hold the Cal key to save the changes A screen will briefly announce that changes have been made and the configuration updated Pressing the MODE button will cancel the changes and save the previous configuration 63 Downloading recorded data PhD record keeping capabilities are most useful when used together wit
66. interval Setting the interval on 00 00 00 will turn the security beep back off 5 3 9 Exiting the Sensor Configuration mode When the PhD is properly configured press and hold the Cal key to save the changes A screen will briefly announce that changes have been made and the configuration updated Pressing the MODE button will cancel the changes and save the previous configuration Chapter 6 Record Keeping 6 1 PhD2 datalogging overview The PhD automatically remembers logs gas readings as well as other important information such as turn on turn off times temperature battery condition and whenever the instrument is calibrated The PhD can store the exposure values for up to 3 000 data intervals This is enough for the storage of up to 50 hours of four gas monitoring broken into as many as 36 individual monitoring sessions when a one minute logging interval is specified Using a longer datalogging interval increases the length of monitoring time for which data may be stored For instance if a data logging interval of two minutes is selected instead of 50 hours 100 hours of monitoring data may be stored This datalogging is a transparent function that is it is not necessary to do anything special to begin logging data Simply turning on the instrument causes it to begin recording data This information may be downloaded to a computer to create a permanent record or directly displayed on the PhD meter scr
67. k that the instrument is turned off If it is not press the MODE button until the message Release button appears on the screen 2 Connect the charger to the dual purpose battery charger RS 232 connector port on the right hand side of the PhD2 Charger datalog connector Figure 2 2 Side view of PhD2 showing the battery charger RS 232 connector 3 Plug in the charger 4 lt is possible to verify that the PhD is properly charging by turning the instrument on while connected to the battery charger and looking at the meter display If the battery charger is functioning properly the screen will briefly display battery voltage V bat and the current delivered by the charger Ich Charging is correct if Vbat is greater than 4 Volts and Ich is greater than 100 mA If a battery is fully charged this screen may not appear or Ich may be lower than 100 mA 5 Press the MODE button for three seconds to turn the instrument off 6 A complete charge requires approximately 8 hours ZAWARNING The PhD detector must not be used in a hazardous area when the battery is being charged The PhD is Classified by Underwriters Laboratories Inc and the Canadian Standards Association as to Intrinsic Safety for use in Hazardous Locations Class I Groups A B C amp D This classification is voided while the PhD is operated while connected to the battery charger in hazardous areas 2 4 Methods of sampling The PhD
68. lace sensor if necessary 7 2 3 6 Problem Unstable oxygen readings Possible causes Sensor failure Loose connection Solution s Check in Diagnostics Test mode 595 935 counts acceptable If sensor checks out examine retaining nuts for tightness Replace O2 sensor if necessary 7 2 3 7 Problem Display is blank Possible causes Battery voltage too low Operating temperature too low Bad LCD display assembly Microprocessor locked up or crashed Solution s Take the instrument to a non hazardous location If cold allow instrument to warm back up to room temperature Plug the PhD into the battery charger for several minutes With the instrument still connected to the battery charger attempt to turn the detector on If this works the battery needs to be recharged or replaced If the instrument still fails to turn on re boot the microprocessor using the procedures discussed in Section 7 2 1 If the instrument still fails to turn on return to factory for repair 7 2 3 8 Problem No audible alarm Possible causes Loose connection alarm failure Solution s Return to factory for repair 7 2 3 9 Problem Function keypad Cal Alarm doesn t work Possible causes Not in Technician mode microprocessor locked up or crashed loose connection switch failure Solution s Switch to Technician operating mode Take the instrument to a non hazardous location Plug the PhD into the battery charger for se
69. m beads These two beads are strung onto the opposite arms of a balanced Wheatstone Bridge circuit The active bead is additionally coated with a platinum or palladium based material that allows catalyzed combustion to occur on the surface of the bead The platinum catalyst is not consumed in the combustion reaction it simply enables it to occur It is not necessary for the combustible vapor to be present in LEL concentrations in order for this reaction to occur Even trace amounts of combustible gas present in the air surrounding the sensor will be catalytically burned on the surface of the bead The reference bead lacks the platinum outer coating but in other respects exactly resembles the active bead A voltage is applied across the active and reference elements causing them to heat If combustible vapors are present the active bead will be heated by the reaction to a higher temperature The temperature of the untreated reference bead is unaffected by the presence of gas The difference between the temperatures of the two beads will be proportional to the amount of combustible gas present Since the two beads are strung on the opposite arms of a Wheatstone Bridge electrical circuit the difference in temperature between the beads is perceived by the instrument as a change in electrical resistance It is important to note that catalytic hot bead type combustible sensors require the presence of oxygen at least 8 10 percent by
70. mple would be a furnace intensive area which always has a background concentration of a few PPM CO To make calibration easy in this case it is necessary to use special calibration Zero Contaminant gas This gas cylinder Biosystems part number 9039 is used in conjunction with the sample draw calibration adapter Flow the zero contaminant gas across the sensors for a minute just as if you were doing a span calibration Then do the fresh air calibration steps described in Chapter 3 of the owner s manual Appendix D Suggested Calibration Gases Use of a calibration standard with a concentration close to the alarm set point of the gas to be measured affords the most accurate calibration of the sensors used in the PhD2 design Because combustible gas sensors have different responses to different combustible gases see Appendix B Biosystems offers three choices Carbon monoxide sulfur dioxide chlorine and hydrogen sulfide are all currently available from Biosystems in small 103 or 58 liter disposable standard calibration gas cylinders Stable calibration mixtures are not available in disposable cylinders for several of the toxic sensors which may be used in the PhD2 detector For these gases it may be necessary to use other types of equipment such as larger high pressure cylinders permeation tubes and ovens or gas generators to deliver the appropriate type of toxic gas to the sensor Please contact the factory for calibration proce
71. n exposure to contaminants by testing with known concentration test gas before further use Failure to check accuracy can lead to inaccurate and potentially dangerous readings 3 2 1 Effects of contaminants on oxygen sensors Oxygen sensors may be affected by prolonged exposure to acid gases such as carbon dioxide The oxygen sensors used in Biosystems instruments are not recommended for continuous use in atmospheres which contain more than 25 CO 3 2 2 Effects of contaminants on combustible sensors Combustible sensors may be affected by exposure to silicone containing substances found in many lubricants and hydraulic fluids the tetra ethyl lead in leaded gasoline halogenated hydrocarbons Freons or solvents such as trichloroethylene and methylene chloride High concentrations of hydrogen sulfide may also damage the sensor The accuracy of combustible sensors may also be affected by exposure to high concentrations of combustible gas To minimize the chance for damage or loss of sensitivity to the combustible sensor the PhD is designed to alarm latch whenever the concentration of combustible gas exceeds 100 percent LEL Under these conditions the combustible alarm sounds continuously the display shows an X for combustible gas and power to the combustible sensor is cut to avoid damage due to over heating The alarms will continue to sound until the instrument is reset The instrument is reset by pressing and hold
72. n operating mode 1 Turn the instrument on and remove it from its carrying case 2 Remove the keypad cover exposing the four push buttons 3 Verify that the instrument is in the Technician operating mode Switch modes if necessary by simultaneously holding down the and keys Each time that the operating mode is changed the meter screen will briefly indicate the current operating mode 4 Turn the instrument off by pressing the MODE button for three full seconds until the release button message appears in the screen 5 With the unit turned off press and hold down the Cal button While holding down the Cal button press the MODE button to turn the PhD back on The calibration message will appear briefly on the screen This message is followed by a screen showing the first gas to be calibrated 6 Page 19 Pressing the MODE button at any time cancels the calibration mode and returns the instrument to the gas reading screen 7 Slip the sample draw calibration adapter over the end of the instrument Make sure to use the adaptor supplied with the hand aspirated sample draw assembly Do not use the battery operated sample draw pump for this purpose 8 Attach the regulator to the calibration gas cylinder Make sure the regulator cylinder seating surfaces and threads are clean and dry ZAWARNING Make sure the regulator cylinder seating surfaces and threads are
73. nderneath the main circuit board Check to see that no ribbon connectors or other components have been disturbed during the procedure 8 Reconnect the two halves of the instrument case 9 Calibrate the instrument before putting it back into service 7 5 Returning your PhD to Biosystems for service or repair Please contact the Biosystems Service Department at 203 344 1079 to obtain a Return Authorization number prior to shipment A Biosystems Service representative Will record all relevant information or special instructions at that time To insure safe transport please use the original PhD2 packing materials or other packing materials which similarly protect the instrument and accessories Note The return authorization number must be clearly marked on the outside of the box Prominently showing the return authorization number on the outside of the box ensures that it is immediately identified and logged into our system at the time it is received Proper tracking helps avoid unnecessary delays in completion of service procedures Note It is usually best to return the instrument together with all accessories such as spare battery packs chargers and optional sample drawing pumps Please contact the Biosystems Service Department if you require any additional information Thank you for choosing the PhD2 and thank you for choosing Biosystems Appendices Appendix A Toxic gas measurement Ceilings TWAs and S
74. nstrument to a non hazardous location Plug the PhD into the battery charger for several minutes With the instrument still connected to the battery charger attempt to turn the detector on If this works the battery needs to be recharged or replaced If the instrument still fails to turn on re boot the microprocessor using the procedures discussed in Section 7 2 1 If the instrument still fails to turn on return to factory for repair 7 2 3 3 Problem LEL sensor readings unstable Possible causes Loose connection bad sensor improper calibration Solution s Check sensor output in Diagnostics Test mode value should be within 200 275 counts Re calibrate Replace the LEL sensor if necessary 7 2 3 4 Problem Toxic sensor readings unstable or numbers flash instead of remaining steady Possible causes Loose connection bad sensor improper calibration or sensor saturated by exposure to excessively high concentrations of gas Solution s Check that the sensor is firmly in place Tighten sensor connections Check sensor in Diagnostics Test mode the value for the sensor in question should be within the range listed in Section 5 2 2 1 If the sensor checks out recalibrate Replace sensor if necessary 7 2 3 5 Problem X appears under channel display for combustible gas Possible causes Sensor failure Loose connection Solution s Tighten connections Check sensor Check output in Diagnostics Test mode Rep
75. ntered while actually using the instrument When it is not possible to calibrate directly to the gas to be measured or when the combustible gas is an unknown an alarm set point of 10 percent LEL or less should be selected In the new standard for Permit Required Confined Space Entry 29 CFR 1910 146 OSHA has determined that a combustible hazard exists whenever the concentration of combustible gas or vapor exceeds 10 percent LEL Per this standard confined spaces with concentrations which exceed 10 percent LEL may not be entered Likewise workers are required to immediately leave anytime readings exceed 10 percent LEL The standard combustible alarm set point for the PhD is 10 percent LEL When not sure what combustible gases might be encountered use a mixture of 1 1 propane in air 50 LEL combustible gas to calibrate Propane provides a sensor response which is more typical of the wide range of combustible gases and vapors than any other calibration mixture 2 1 Calculating relative responses There are theoretical ways to estimate the relative response of a sensor calibrated on one combustible gas to exposure to another gas This is done by taking the actual instrument reading and multiplying it by a correction factor It is very important to treat gas concentration calculations based on theoretical relative response ratios cautiously In actual practice the relative response varies somewhat from sensor to sensor T
76. nts can lead to dangerously inaccurate readings and may void the standard Biosystems warranty 7 NNARNING Use of non standard calibration gas and or calibration kit components when calibrating the PhD2 can lead to inaccurate and potentially dangerous readings and may void the standard Biosystems warranty Biosystems offers calibration kits and long lasting cylinders of test gas specifically developed for easy PhD2 calibration Customers are strongly urged to use only Biosystems calibration materials when calibrating the PhD2 8 ZNVARNING Substitution of components may impair intrinsic safety AVERTISSEMENT LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA S CURIT INTRINSEQUE 9 ZAWARNING For safety reasons this equipment must be operated and serviced by qualified personnel only Read and understand this reference manual before operating or servicing the PhD2 ATTENTION POUR DES RAISONS DE S CURIT CET QUIPMENT DOIT ETRE UTILIS ENTRETENU ET R PAR UNIQUEMENT PAR UN PERSONNEL QUALIFI TUDIER LE MANUEL D INSTRUCTIONS EN ENTIER AVANT D UTILISER ENTRETENIR OU DE R PARER L QUIPMENT 19 ZAWARNING A rapid up scale reading followed by a declining or erratic reading may indicate a hazardous combustible gas concentration that exceeds the PhD2 s zero to 100 percent LEL detection range AVERTISSEMENT TOUTE LECTURE RAPIDE ET POSITIVE SUIVIE D UNE BAISSE SUBITE AU ERRATIQUE DE LA VALEUR PEUT INDIQUER UNE CONCENTRATION DE GA
77. o compute a toxic gas STEL until the PhD has been monitoring for at least fifteen minutes Until the minimum monitoring time has elapsed the STEL screen will show an X where the reading should be Anytime after the first fifteen minutes have elapsed the STEL screen will show the appropriate numerical value Pressing the MODE button again displays TWA Time Weighted Average exposure levels TWA values are calculated by projecting exposures over an eight hour period It is not possible to compute a toxic gas TWA until the PhD has been monitoring for at least one hour Until the minimum monitoring time has elapsed the TWA screen will show an X where the reading should be The screen also indicates how many completed full hours the instrument has been on If the PhD has been on for less than one full hour the screen indicates 0 completed hours Pressing the MODE button again displays the final screen showing clock time number of data points saved temperature run time and battery voltage Pressing the MODE button again toggles the display back to the first screen showing current gas levels 2 2 4 Changing operating modes It is possible to shift from one operating mode to another while the instrument is in use without the loss of data It is not necessary to turn the instrument off before switching Simply remove the keypad cover to expose the four mini push buttons and simultaneously push the and
78. o erase the information stored in the PhD2 record keeping file use the following simple procedure Immediately after the Uploading to PC completed message appears press the Cal button You will have two seconds before the unit returns to normal operation If the Cal button is depressed within the allotted time frame the following screen will be displayed Press the alarm button to clear data You will have two seconds to do so before the clear data function is canceled and the unit resumes normal operation 6 3 6 Exiting the Record Keeping Data Please note The Computer Link Kit manual contains Transfer mode a more complete discussion of how to set up your computer hardware and software directories to Exit the data downloading mode by using the MODE receive data downloaded from the PhD2 button to turn the PhD2 off in the usual manner Page 32 Chapter 7 Trouble shooting and repair Repair procedures may only be performed by authorized personnel 7T 1 Changing PhD2 sensors The PhD must be turned off prior to removing or replacing sensors A Phillips screwdriver is used to remove the three screws securing the sensor cover to the PhD case 7 1 1 Replacing toxic sensors 1 Identify which of the two toxic sensors you wish to replace 2 Gently pry the sensor out of its socket 3 Press the replacement sensor into place 4 Allow at least one hour for the sensor to stabilize Nitric oxide NO hydrogen
79. on Database program is also available This program allows you to store information on a PC and retrieve it for further analysis 12 PhD2 design components 1 Case The instrument is enclosed in a solid stainless steel impregnated polycarbonate case A water resistant PVC gasket between the upper and lower sections of the case protects against leakage or exposure to liquids 2 Front face The front face of the instrument houses the meter display alarm lights and photo sensor 3 LCD display A Supertwist liquid crystal display LCD meter allows display of readings messages and other information 4 Alarm lights Four LED light emitting diode alarm lights provide a visual indication of alarm state Each light is dedicated to a single gas and emits a bright red light when a sensor alarm level is exceeded 5 Photo sensor A photo sensor is used to monitor the level of background illumination A back light automatically brightens the meter display whenever the instrument is taken into a dark area 6 On Off MODE button The large black push button is called the MODE button It is used to turn the PhD2 on and off as well as to control most of the operations of the instrument 7 Key pad cover The key pad cover protects the four mini push buttons on the instrument key pad 8 Sensor compartment cover The sensors are protected by a vented sensor compartment cover A water resistant PVC gasket and inner liner
80. oncentrations of toxic substances exceed the ceiling level The Time Weighted Average or TWA is the maximum average concentration to which an unprotected worker may be exposed over an eight hour working day During this time STEL and ceiling concentration limits may not be exceeded OSHA has assigned some but not all toxic substances with a Short Term Exposure Limit The STEL is the maximum average concentration to which an unprotected worker may be exposed in any fifteen minute interval during the day During this time neither the eight hour TWA or the ceiling concentration may be exceeded Any fifteen minute periods in which the average STEL concentration exceeds the permissible eight hour TWA must be separated from each other by at least one hour A maximum of four of these periods are allowed per eight hour shift The table below shows the highest levels at which these alarms should be set If OSHA has not determined a ceiling value for greatest safety the PhD ceiling alarm should be set at the same value as the STEL alarm If OSHA has not determined a STEL value the PhD2 STEL alarm should be set at the same value as the TWA 4 U S Department of Labor Occupational Safety and Health Administration OSHA 1989 Permissible Exposure Limits for select toxic gases In the following table NA indicates no value has been assigned by OSHA Note Customers should be aware that OSHA permissible exposure limits may be subject
81. onic self test and start up sequence that takes approximately twenty seconds During the self test sequence the meter display back light will momentarily turn on the visual LED alarm lights will flash and the audible alarm will sound During start up the LCD display will also display several messages or screens in sequence The first screen displays the software version number The second screen shows time and date The third screen shows the PhD is conducting an electronic self test If the instrument has been turned on while in the Basic or Technician mode three additional screens are briefly displayed These screens are omitted in the Text Only mode start up sequence The first shows clock time number of data points saved temperature run time and battery voltage The second shows the PhD data memory being checked The third shows sampling interval and duration for memory At the end of the start up sequence the last screen will display current gas level readings 2 1 3 Turning the PhD2 off Holding the MODE button down for three seconds turns the instrument off In order to prevent accidental shut downs the MODE button must be depressed for a full three seconds in order to turn the instrument off After three seconds marked by three beeps of the audible alarm the LCD display will display the message Release button If the button is released prior to the Release button mess
82. or designed to protect the PhD from exposure to water or other liquids If there is a change in pressure in the sample draw assembly due to fluid intake the pump immediately shuts down After a few seconds audible and visual alarms indicating a low flow condition will also be activated Note Make sure that the sample draw tube is not inserted into a fluid horizontally or at a low angle The pressure sensor in the sample draw pump is designed to detect changes while the sample draw probe is being held in a vertical position If the probe is held horizontally or at a low angle when inserted into a fluid a pressure drop sufficient to cause the pump to shut down may not be generated In order to avoid potential damage care must be taken to keep the probe vertical any time fluids might be present To operate the sample draw pump 1 2 3 4 Connect the slip on battery operated pump with the hose and probe assembly Remove the PhD from its protective vinyl carrying case Slip the battery operated pump over the end of the PhD Lightly tighten the retaining screw to secure the pump to the instrument Turn the sample draw pump on Cover the end of the sample draw probe assembly with a finger If there are no leaks in the sample draw kit components the pump should go into a low flow alarm and immediately shut down and the audible and visual low flow alarms should be activated Reset the pump by turning it off and
83. paces must be tested for oxygen deficiency before entry Normal fresh air contains 20 9 percent O2 Any environment in which the oxygen concentration is less than 19 5 percent has been determined by OSHA to be oxygen deficient The normal PhD low alarm setting for oxygen deficiency is 19 5 percent Common causes of this hazard are bacterial action displacement of oxygen by other gases oxidation rusting consumption burning or absorption by materials such as wet activated carbon The PhD will also alarm for an excess of oxygen Too much oxygen in an environment can result in an increased flammability hazard The new OSHA standard for confined space entry 29 CFR 1910 146 requires that oxygen concentrations not exceed 23 5 percent The normal setting for the high oxygen alarm is 23 5 percent 2 Combustible gas alarms As an environment becomes contaminated with combustible gases or vapors concentrations can climb until they eventually reach ignitable or explosive levels The minimum amount of a combustible gas or vapor in air which will explosively burn if a source of ignition is present is the Lower Explosive Limit LEL concentration PhD combustible gas readings are given in percent LEL with a range of zero to one hundred percent explosive The PhD combustible gas sensor is non specific and responds to all combustible gases and vapors Combustible sensors contain two coils of fine wire coated with a ceramic material to for
84. rect Toxic 1 sensor type from the menu and update the new values 11 Calibrate the new sensor before use 5 3 4 Changing the precision of the toxic sensor read out It is possible to change the precision that is the placement of the decimal point in the read out for a toxic sensor The toxic gas read out may be either in full parts per million PPM increments or in tenths of parts per million 0 1 PPM increments If 0 1 PPM increments are selected the toxic channel screen shows the indicator A X If full PPM increments are selected the screen does not display a precision indication The Toxic 1 channel configured for a chlorine CI2 sensor with a readout precision of 0 1 PPM will show the following screen Pressing the Alarm button changes the readout precision Pressing the Cal button advances to the second Toxic 2 channel 5 3 5 Adding an instrument identification number Pressing the Cal button again advances to the Serial Number Text Only readout latch screen Page 27 An identification number is added or changed by using the and keys Any five digit ID number between 1 and 65 535 may be selected Select 0 if no ID number is desired 5 3 6 Text Only operating mode readout latch The OK latch indicator means that when the PhD is operated in the Text Only mode if the latch is activated ON after an alarm condition has cleared numbers remain on the screen rather than the s
85. rocedure or making use of other advanced PhD functions Calibration procedures are discussed in detail in Chapter 3 After the completion of the start up and self test sequence the meter display will show numeric readings of the gases being measured If an alarm condition occurs that is when one of the sensor readings exceeds a pre set alarm level the numerical reading changes to reflect the new value the LED alarm light flashes and the audible alarm sounds PhD alarms are normally self resetting When readings drop back below the pre set alarm levels visual and audible alarms cease and normal operation of the instrument resumes Pressing the MODE button allows the user to toggle between available meter display screens Several additional screens are available to the user in the Technician mode The first screen is the gas level display discussed above Pressing the MODE button once displays the peak readings of the gases being measured during the current monitoring interval The instrument will automatically cycle between two peak reading screens one for oxygen and one for the other gases being measured The oxygen peak reading screen shows both the high HI and low LO readings Pressing the MODE button again displays the STEL Short Term Exposure Levels of the toxic gases being measured Since STEL calculations are made using the most recent fifteen minute monitoring interval it is not possible t
86. rs in this screen signify the session number 0 the time the session was started and completed 12 37 14 54 the date of the monitoring session and the location identification number if one has been assigned The and keys may be used to select another session Remember 0 is the most recent session 1 is the session before last etc Pressing the MODE button allows the peak readings from session O to be viewed The instrument will automatically cycle between two peak reading screens one for oxygen and one for the other gases being measured The oxygen peak reading screen shows both the high HI and low LO readings Pressing the MODE button takes the screen back to the monitoring session display 6 3 3 Entering a monitoring location identification number It is possible if desired to assign an identification number specifying the location where a particular monitoring session occurred This may be done while in any of the normal operating modes Text Only Basic or Technician While monitoring in the normal gas reading screen press the key to enter the location identification number assignment screen The and keys are used to enter the identification number 6 3 4 Downloading recorded data to a computer PhD record keeping capabilities are most useful when used together with the Biosystems Personal Computer PC Based Gas Detector Database software To interface t
87. scussed in Section 3 4 and flow calibration gas to the sensors Wait for the readings to stabilize Forty five seconds to one minute is usually sufficient Note the readings Oxygen readings are considered to be accurate when the display is within 0 5 of the expected concentration as given on the calibration gas cylinder LEL and toxic readings are considered accurate when they are between 90 and 120 of the expected value as given on the calibration gas cylinder If readings are accurate there is no need to adjust your gas detector If the readings are inaccurate the instrument must be be adjusted using the span calibration procedures discussed in Section 3 4 before further use Note All in one calibration mixtures are particularly useful in functional test procedures Appendix D lists currently available mixtures 3 2 Effect of contaminants on PhD2 sensors The atmosphere in which the PhD monitor is being used can have an effect on the sensors Sensors may be poisoned or suffer degraded performance if exposed to certain substances There are three basic types of sensors that may be installed in the PhD detector oxygen combustible gas LEL and electrochemical toxic Each type of sensor uses a slightly different detection principle The kinds of conditions that affect the accuracy of the sensors varies from one type of sensor to the next ZAWARNING The accuracy of the PhD2 should be checked immediately following any know
88. sh button is used to turn the instrument on and off and to switch screens Pressing the large black MODE button allows the user to toggle between available meter display screens Two screens are available to the user in the Text Only mode The first screen is the gas level display discussed above Pressing the MODE button displays the second screen which shows battery voltage running time for the instrument and temperature Pressing the MODE button again toggles the display back to the first screen showing current gas levels 2 2 2 Basic mode The Basic mode of operation is designed for users with a higher level of understanding and a need for numerical readings but who are not experts in gas detection In the Basic mode as in the Text Only mode the user has access to only two screens of information In both the Text Only and Basic modes only one push button the MODE button is used to turn the instrument on and off and to switch screens The major difference between the two modes is that in the Basic mode numerical gas level readings are provided whereas in the Text Only mode only an indication that conditions are OK is provided during normal operation Another important difference is that it is possible to do a fresh air calibration adjustment while in the Basic mode This feature is not enabled when the instrument is operated in the Text Only mode Calibration procedures are discussed in detail in Chapter 3
89. short time Never enter an environment even momentarily when concentrations of toxic substances exceed the ceiling level Time History Graph c Ceiling 2 Time Weighted Average TWA The maximum average concentration to which an unprotected worker may be exposed over an eight hour working day During this time STEL and ceiling concentration limits may not be exceeded Time History Graph TWA 8 hour 3 Short Term Exposure Limits STEL Toxic substances may have short term exposure limits which are higher than the eight hour TWA The STEL is the maximum average concentration to which an unprotected worker may be exposed in any fifteen minute interval during the day During this time neither the eight hour TWA or the ceiling concentration may be exceeded Any fifteen minute periods in which the average STEL concentration exceeds the permissible eight hour TWA must be separated from each other by at least one hour A maximum of four of these periods are allowed per eight hour shift Time History Graph Ceiling STEL TWA 15 Minutes Page 37 Appendix B How to determine where your alarms should be set 1 Oxygen alarms Two oxygen alarm set points have been provided one for low concentrations associated with oxygen deficiencies and one for high concentrations associated with oxygen enrichment Oxygen deficiency is the leading cause of worker fatality during confined space entry All confined s
90. stream must be broken into discrete intervals before being logged The sample interval screen allows the user to adjust how frequently this data is logged Calculations that are made on a running basis i e TWA STEL Ceilings and Peak exposure values are updated several times per second by the PhD microprocessor Adjusting the sampling interval used by the PhD to generate time history exposure files does not alter the way in which TWA STEL Ceiling and Peak exposure values are calculated The sampling interval may be set anywhere between one second and one hour by using the and keys The PhD is capable of logging 3000 intervals of data The bottom line on the interval adjust screen calculates how many hours of data logging are available with the currently selected interval value For instance in the example screen above an interval of 1 minute has been selected This interval allows 50 hours of data logging before the PhD memory is full If an interval value of 30 seconds is selected the following screen will be displayed In the event the memory is full the PhD is designed to hold on to the most recent 3000 data intervals In the case above that means the most recent 25 hours of monitoring Selecting a longer sampling interval allows the retention of more hours of data If an interval of 15 minutes is selected the detector is able to log 750 hours of monitoring data making the PhD ideal for long term sampl
91. t relatively low concentrations Exposure to a 1 000 PPM parts per million concentration of H2S in air produces rapid paralysis of the respiratory system cardiac arrest and death within minutes Carbon monoxide CO is a good example of a chronically toxic gas Carbon monoxide bonds to the hemoglobin molecules in red blood cells Red blood cells contaminated with CO are unable to transport oxygen Although very high concentrations of carbon monoxide may be acutely toxic and lead to immediate respiratory arrest or death it is the long term physiological effects due to chronic exposure at lower levels that take the greatest toll of affected workers This is the situation with regards to smokers parking garage attendants or others chronically exposed to carbon monoxide in the workplace Exposure levels are too low to produce immediate symptoms but small repeated doses reduce the oxygen carrying capacity of the blood over time to dangerously low levels This partial impairment of the blood supply may lead over time to serious physiological consequences Because prudent monitoring programs must take both time frames into account there are three independent exposure measurements and alarm types built into the PhD5 design 1 Ceiling level OSHA has assigned some but not all toxic substances with a ceiling level This is the highest concentration of a toxic substance to which an unprotected worker should ever be exposed even for a very
92. t will not be made A message screen indicating that the zero values have not been changed will be briefly displayed and the instrument will be returned to normal operation 3 3 1 2 Fresh air zero through mini push buttons 1 Turn the instrument on Wait at least three minutes after turning the instrument on to allow sensor readings to stabilize fully before initiating the fresh air zero procedure 2 3 Remove the key pad cover exposing the four mini push buttons 4 Verify that the instrument is in the Basic or Technician operating mode Switch modes if necessary by simultaneously holding down the and keys Make sure the instrument is located in an area where the air is known to be fresh 5 6 Press the push button marked Cal The fresh air calibration message will appear briefly in the meter display 7 The fresh air calibration message is followed by the zero adjustment screen The PhD automatically zeroes the instrument readings when the Cal button is pushed An information screen is briefly displayed while the adjustments are being made and another when the adjustments have been completed 8 Pressing the large black MODE button causes the calibration values in the memory to remain unchanged from the last time a fresh air adjustment was made An information screen is displayed briefly which verifies that the zero values have not been changed
93. ternally removable NiCad battery simply leave the battery installed in its normal position on the bottom of the lower half of the instrument case 4 Remove the four Phillips head screws securing the main circuit board to the instrument case 5 Disconnect the ribbon cable which connects the main board to the meter display board 6 Carefully remove the PROM chip IC 10 from its socket See Figure 7 3 for location of IC 10 Note Biosystems strongly recommends use of a PROM removal tool or chip puller to remove the IC Chip pullers are readily available at your nearest electronics supply store 7 Insert the new PROM chip into the socket being careful to properly align position marks Note the position of the squared corner The chip is designed to fit in only one way 8 Reinstall the main board Reconnect the ribbon cable connecting the main board to the meter display board Be careful not to crimp any wires as the main board Is reattached 9 Reinstall the battery Make sure all ribbon connectors are properly attached 10 Reassemble the case 11 Turn the instrument back on Verify that all settings are correct Note If the PhD2 does not operate normally when first turned back on it may be necessary to re boot the microprocessor software Turn the instrument off and re boot the microprocessor as discussed in Section 7 2 1 12 Calibrate the instrument before returning to service So
94. the nature of the reaction each gas has with the sensor the effect can either decrease the signal negative cross sensitivity or increase the signal positive cross sensitivity Each figure represents the reaction of the sensor to 100 PPM of gas thus providing a percentage siii to that gas relative to its 2 gas Mil lod i L re qo PTS ene Carbon T T Cee CO Hydrogen 20 lt 25 sulfide H3S Sulfur dioxide SO9 Nitric oxide Sree e NO d SIR REE dioxide NO gt 5 ATTN 20 20 sulfide H25 Chlorine Cl5 Hydrogen E isl MM 1 Mt 1 hall 1 ERE cyanide HCN Hydrogen 100 285 20 30 chloride HCI Ammonia e 50 NH3 1Data derived in part from City Technology Limited Product Data Handbook Oct 1 1992 2Tox1 data obtained from sensors calibrated with 50 PPM carbon monoxide in air 3Extended range Hydrogen sulfide sensor 0 500 PPM Page 43 Appendix F PhD2 sensor ranges The following tables display the ranges for curren by available sensors for use in the PhD2 Nominal range values indicate the gas level range which the PhD can detect over extended periods of operation Max overload values indicate the highest instantaneous reading that the PhD will be able to attain for a given sensor type m e pm esee m m Ranges indicate CO levels for a broad range TOX 1 sensor calibrated with CO Page 44 Appendix G Calibration Frequency One of the most common q
95. then back on Insert the end of the sample probe into the location to be sampled Wait long enough for the pump to have drawn the sample through the entire length of hose and for the sensors to have stabilized Allow one additional second for each foot of sample hose Particulate filter 8 Note gas measurement readings If a protective pump shut down occurs the following steps should be taken before the instrument is put back into use 1 2 3 4 6 7 Sample draw PhD2 Assembly Turn off the sample draw pump Remove the sample draw assembly from the area being monitored Be careful to keep the sample draw probe in a vertical position Examine the sample draw probe and hose to make sure no fluids remain trapped Allow any trapped fluids to completely drain It may be necessary to disconnect the hose or sample draw probe before drainage can occur Replace the sample probe particulate and moisture barrier filters if necessary Turn the pump back on in fresh air and wait for readings to stabilize Continue to sample Hydrophobic barrier f11 Model 1655A automatic sample draw pump Retaining Figure 2 4 2 Model 1655A sample draw pump installation Page 16 Chapter 3 Calibration The PhD detector has been designed for easy calibration Adjustments are made by using simple push button controls located on the instrument keypad ZAWARNING The accuracy of the PhD2 s
96. ther a sensor needs to be replaced Accuracy of the PhD2 must be checked with known concentration calibration gas before each day s use Unstable or erratic readings or inability to calibrate may indicate a sensor is approaching the end of life or has been contaminated ZAWARNING Sensors that cannot be calibrated should be replaced immediately 5 2 1 Entering the Diagnostics Test mode The Diagnostics Test routine is entered by using the MODE button to turn the detector on while simultaneously holding the and buttons down The message Diagnostic Test will briefly appear on the screen The screen will also indicate the version of the PhD microprocessor software currently installed This screen will be followed by another which briefly shows the release date of the software version currently installed in the PhD and the instrument identification number The next screen shows the raw output of the combustible gas LEL and oxygen sensors Please note that LEL values 250 counts in the example screen below are listed to the left oxygen values 755 counts to the right hand side of the screen By pressing the MODE button you can advance to the next screen which shows the raw output for the toxic sensors The values for the sensor installed in Toxic sensor channel 1 are listed to the left Toxic sensor channel 2 to the right 5 2 2 Diagnostic counts Diagnostic counts represent the raw electrical output
97. thing in the atmosphere that is poisoning the sensor s The period of initial use must be of sufficient duration to ensure that the sensors are exposed to all conditions that might have an adverse effect on the sensors 2 If these tests demonstrate that it is not necessary to make adjustments the time between checks may be lengthened The interval between accuracy checking should not exceed 30 days 3 When the interval has been extended the toxic and combustible gas sensors should be replaced immediately upon warranty expiration This will minimize the risk of failure during the interval between sensor checks 4 The history of the instrument response between verifications should be kept Any conditions incidents experiences or exposure to contaminants that might have an adverse effect on the calibration state of the sensors should trigger immediate re verification of accuracy before further use 5 Any changes in the environment in which the instrument is being used or changes in the work that is being performed should trigger a resumption of daily checking 6 If there is any doubt at any time as to the accuracy of the sensors verify the accuracy of the sensors by exposing them to known concentration test gas before further use Gas detectors used for the detection of oxygen deficiencies flammable gases and vapors or toxic contaminants must be maintained and operated properly to do the job they were d
98. tor or use of keypad push buttons in unauthorized combinations may occasionally cause the microprocessor to lockup or crash In this event it may be necessary re boot the microprocessor before the PhD can be turned back on and put back into normal operation The most significant symptom of a microprocessor which has locked up is inability to turn the instrument back on in the normal manner Inability to turn the instrument on may also result from a dead battery Make sure the battery is charged before attempting to re boot If the re boot is unsuccessful try the procedure again while the instrument is connected to a 110 VAC power source through the battery charger Note The PhD detector must not be located in a hazardous location while the battery is being charged or while the instrument is being operated while connected to the battery charger The PhD is Classified by Underwriters Laboratories Inc as to Intrinsic Safety for use in Hazardous Locations Class I Groups A B C and D This classification is voided while the PhD is operated while connected to the battery charger in hazardous areas To re boot the microprocessor 1 Press and hold down the large black on off MODE button for thirty seconds 2 Release the button 3 Press the on off MODE button to turn the instrument on in the normal manner If the re boot procedure has been successful the instrument should resume normal operation 7 2 2 Re initi
99. toxic It is possible if desired to set PhD2 gas alarms so that hazards Biosystems also offers the TOX 1 broad range they latch In the latched condition once an alarm electrochemical sensor for situations requiring use of a occurs both visual and audible alarms continue to sound single sensor to monitor for multiple toxic hazards even after the atmospheric hazard has cleared The Page 7 instrument must be manually reset before the alarms are silenced 1 1 5 Atmospheric hazard alarms ZAWARNING The PhD2 personal portable gas detector has been designed for the detection of dangerous atmospheric conditions An alarm condition indicates the presence of a potentially life threatening hazard and should be taken very seriously ZAWARNING in the event of an alarm condition it is important to follow established procedures The safest course of action is to immediately leave the affected area and to return only after further testing determines that the area is once again safe for entry Failure The combustible gas alarm is activated when the percent LEL Lower Explosive Limit gas concentration exceeds the pre set alarm point ZAWARNING A rapid up scale reading followed by a declining or erratic reading may indicate a hazardous combustible gas concentration that exceeds the PhD2 s zero to 100 percent LEL detection range Two oxygen alarm set points have been provided one for low concentrations associated with oxygen defi
100. uestions that we are asked at Biosystems is How often should calibrate my gas detector Sensor Reliability and Accuracy Today s sensors are designed to pro vide years of reliable service In fact many sensors are designed so that with normal use they will only lose 596 of their sensitivity per year or 1096 over a two year period Given this it should be possible to use a sensor for up to two full years without any significant loss of sensitivity A lot of sensors indeed do last that long with only minimal loss of sensitivity However there are a number of reasons why a senso may unexpectedly lose additional sensitivity or even fail to respond to gas Such reasons include desiccation poisoning physical restriction of X airflow overexposure leakage and mechanical damage due to dropping or immersion Verification of Accuracy With so many reasons why a sensor can lose sensitivity and given the fact that dependable sensors can be key to survival in a hazardous environment frequent verification of sensor performance is paramount There is only one sure way to verify that a sensor can respond to the gas for which it is designed That is to expose it to a known concentration of target gas and compare the reading with the concentration of the gas This is referred to as a bump test This test is very simple and takes only a few seconds to accomplish The safest course of action is to do a bump test prior
101. veral minutes With the instrument still connected to the battery charger attempt to turn the detector on If this works the battery needs to be recharged or replaced If the instrument still fails to turn on re boot the microprocessor using the procedures discussed in Section 7 2 1 If keypad buttons still fail to function return to factory for repair 7 3 Changing the PhD2 microprocessor PROM chip The PhD is a microprocessor controlled design A Programmable Read Only Memory PROM chip located on the main circuit board is used to program the instrument New microprocessor software versions are installed by removing the old PROM chip and replacing it with the newer version Note PROM chip replacement requires opening the instrument and removing an electronic component located on the main circuit board of the detector This procedure should not be done by unauthorized persons In many cases it may be better to return the detector to the factory for this procedure To replace the PhD2 PROM chip 1 Make sure that the PhD is turned off 2 Remove the five screws holding the instrument case together and separate the two halves of the case 3 If the PhD is equipped with an internally housed lead acid battery carefully pull the battery free of the case Be careful not to disconnect the battery from the main board Disconnection of the battery will result in the loss of recorded data If the PhD is equipped with an ex
102. y pack into the PhD2 case Over tightening may lead to the battery pack being damaged eo e Removeable Mi ad NE battery pack ut Figure 2 1 PhD2 showing removable NiCad battery pack 2 3 1 2 Sealed lead acid The PhD2 may also be equipped with an internally housed sealed lead acid rechargeable battery Removal or replacement of the sealed lead acid battery requires disassembly of the instrument case ZAWARNING The sealed lead acid battery may not be removed or replaced while the PhD is being used or located in a hazardous location CAUTION Removal of the sealed lead acid battery Will result in the immediate loss of recorded gas measurement data Recorded gas measurement data should be downloaded before disconnection of the sealed lead acid battery Calibration and configuration data are stored in a non volatile permanent memory and are not subject to loss due to battery removal 2 3 2 Battery life Allow the PhD to operate two to three minutes before checking battery voltage A reading of 6 4 volts or higher indicates the battery is sufficiently charged for use A fully charged PhD battery should allow for eight hours of continuous operation If the expected duration is not being received try cycling the battery by turning it on for a few hours every day then recharging If this procedure fails to improve performance the battery will probably need to be replaced To ensure the best performance