Perlick CS1DPSP User's Manual
Contents
1. OUTLET WHITE ry THERMOSTAT BLACK e x W O E Q J i CONDENSING UNIT BLACK H POWER CONNECTION l WHITE i D GREEN a J JUNCTION BLOCK Ralick 8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 CORPORATION Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2091A 6 Rev 08 03 04
2. INSTALLATION AND OPERATION INSTRUCTIONS SINGLE DOOR BACK BAR COOLER eee IMPORTANT INFORMATION A Warranty card is enclosed that must be filled out and mailed to the Perlick Corporation in order to reg ister the warranty If the card is not returned to Perlick the warranty period will begin from the date the equipment is shipped from the factory This manual has been prepared to assist you in the installation of your Single Keg Dispenser and to acquaint you with its operation and maintenance We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction If service is required your dealer can provide you with a list of qualified service agents For your own protection never return merchandise for credit without our approval We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction WARNING When lifting the full weight of the cabinet must be supported Lift from the cabinet base and not from the top Improper lifting can result in severe damage to the cabinet eal ick CORPORATION MODEL NOS CS1DPSP opie cU us XO EPH LISTED ANSI NSF 7 5 Year Compressor Warran Table of Contents PREPARING THE CABINET FOR USE SPOCIHICATIONS aedececierocterecccavidiieteec cadets List of Included Parts c ccceeeees Tools Required PIUMDINQ eaaet Electrical ernan eters olan oars LINGALA a
3. Shelf Clips Tools Required m 2 Phillips Screwdriver 10 Crescent Wrench 9 16 Allen Wrench 3 8 Nut driver power Drill or Driver for Leg Installation Plumbing Features a floor drain with a 3 4 female pipe thread connection for disposal of condensate Remove bottom or side drain plug with Allen wrench and attach 3 4 male pipe to external drain Electrical The cabinet must be connected to a separately fused power source see electrical specification plate and grounded in accordance with National and Local Electrical Codes Caution Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate Uncrating and Inspection Remove all crating material before operating Carefully inspect cabinet for hidden damage If damage is discovered file your claim immediately with the transportation company Perlick is not responsible for damage in transit Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Attach four casters to the cabinet bottom rigid cast ers at the rear and swivel casters on the front Use the supplied 4 20 x 3 4 hex head self tapping machine screws Placing the Cabinet Push the cabinet into place using rollers when necessary Important Proper air flow around the condensing unit is necessary for efficient operation Never obstru
4. and lock Base is black painted galvanized steel Full back panel with air gap vent on top REFRIGERATION R 134a capillary tube type Aluminum fin and copper tube evaporator coil Adjustable temperature control Self defrosting VENTILATION Two inches of clearance is required behind cabinet for proper air flow ELECTRICAL 115 Volt 60 Hz 1 Phase AC Furnished with three prong six foot rubber cord Contact Perlick Milwaukee for other voltages frequency requirements PLUMBING Floor drain 3 4 female taper pipe exits out right bottom or right end VENTILATION Requires tow inches of clearance at back of cabinet for proper air flow OPTIONAL ACCESSORIES Leg Set Caster Set e Leg amp Front Base Plate 20 1 4 514 BACK TO INSIDE OF DOOR PAN ee I 4 4 l a 2n 3 9 32 83 9 ALR 4 Pee uN ee i f t 5 11 16 144 CONDENSER 61 40 AIR DISCHARGE oe il Peat j 3 or i ar 28 11 16 PUN 34 7 16 hoaa DOOR ai eee ji B Baai OPENING OPENING rr ees A L Ea E a a s oE i Fs M 5 2 1 4 3 25 32 10 25 32 3 29 32 57 20 273 99 CONDENSER 27 3 4 AIR INTAKE 705 Form No Z2091A Rev 08 03 04 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Preparing the Cabinet for Use Single Door Back Bar Cooler Parts List Installing Casters Optional m 2 Shelves m Mini Flourescent Light m
5. ct the air flow in and out of the condensing unit A minimum of 2 clearance is required from back Leveling the Cabinet When the cabinet is in place check installation with carpenter s level When perfectly level accumulated water will drain out A slight pitch to the drain side will not harm the cabinet Water may accumulate if cabinet is pitched to the opposite side Installing Base Plate optional Attach brackets to cabinet bottom in holes provided Use 10 self drilling hex sheetmetal screws See separate instructions provided with kit When returning cabinet to upright position be careful not to bend brackets WARNING To avoid compressor damage after returning cabinet to an upright position let unit stand for 24 hours before plugging it in and running the unit Perlick CORPORATION Form No Z2091A Rev 08 03 04 General Information Single Door Back Bar Cooler Refrigeration and Temperature Control Cleaning the Cabinet The Back Bar cabinet is equipped with a heavy duty refrigeration system designed to automatically maintain a storage temperature of 36 41 degrees F The control is factory set at 38 degrees F NORMAL Q 8 2 m 5 5 Adjusting the temperature The temperature control is inside the cabinet on the right hand side of the evaporator fan panel assembly You will need a screwdriver to turn the adjusting screw Make small adjustments u
6. lick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Replacement Parts Single Door Back Bar Cooler MODEL NOS CS1DP Item Description Part s 1 Compressor for R134a C22650 2 Condenser fan motor C15240A 3 Condenser fan motor bracket 61289 1 4 Condenser fan blade C6914 5 Condenser fan pan 62209 1 6 Rear panel 62433 1 7 Back panel partition 62131 1 8 Condenser assembly C18634A 9 Condenser panel 62132 1 10 Evaporator fan guard C25400A1 11 Evaporator fan blade 51 C14649 12 Evaporator fan motor C15239A 13 Evaporator assembly complete 62212B 14 Top assembly 62439 15 Temperature control parts kit 57360 16 Right hinged door assembly 64357SRBL Left hinged door assembly 64357SLBL 17 Door hinge kit right 63407R Door hinge kit left 63407L 18 Magnetic door gasket 62085 1 19 Door sill 60944 1 20 Door handle C31409 1 Parts Not Shown on Drawing Light mini flourecent 57822A Wiring harness 61346 1 Door lock with keys 57851 Drain line hose kit 57854 44 Ferkel CORPORATION Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2091A Rev 08 03 04 5 Wiring Diagram Single Door Back Bar Cooler EVAPORATOR FAN BLACK 4
7. nirnar Installing Casters ceeeeeeeeeseeeeeeees Placing the Cabinet 0 cccceeeeeees Leveling the Cabinet cceeeee Installing Base Plates ee TEMPERATURE Refrigeration and Temperature Control Adjusting the Temperature 005 CLEANING Cleaning the Cabinet cceeeee Cleaning the Condenset ccc08 GONGONSEM icen eae a n a GENERAL INFORMATION REPLACEMENT PARTS Xi ccicecectceestecees Wiring Diagram 8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Form No Z2091A Rev 08 03 04 Installation and Operating Instructions Sizes and Specifications Single Door Back Bar Cooler Ut s 4 LISTED ANSI NSF 7 5x Gar Warrani MODEL NOS CS1DPSP CONDENSING UNIT H P V eh p AMPS 3 2 SHIP WT lbs kg 205 93 INTERIOR Door Sill Reinforced 14 gauge stainless steel sill Door Pan High strength polystyrene Floor Pan Stainless steel Walls amp Ceiling Galvanized steel Includes pilasters two shelves and one 1 mini flourescent energy efficient light EXTERIOR Stainless steel top with square edges Door front back and ends black texture painted steel Decorative handle
8. ntil the desired temperature is achieved m Colder Temperatures Turn the adjusting screw clockwise to the right Warmer Temperatures Turn the adjusting screw counterclockwise to the left In normal operation the condensing unit will run approximately 16 hours per day The condenser fan motor turns off and on with the condensing unit The evaporator fan motor runs continuously The fan motors are lifetime lubricated and will require no oiling NOTE Cabinet Temperatures lower than 34 will not allow for proper defrosting of the evaporator coil If defrosting is necessary turn the control knob to the OFF position until coil is defrosted Terlicl CORPORATION Form No Z2091A Rev 08 03 04 Use a mild detergent and water to clean the inside and outside of the cabinet Dry thoroughly Never use a scouring pad or abrasive cleanser NOTE An industrial strength commercial cleaner can be used to clean the outside of painted cabinets Cleaning the Condenser Use a long handled stiff brush to clean the dirt from the front surface of the condenser Keeping the condenser free from dust and dirt will ensure effi cient operation CAUTION Do not bend the fins while brushing the front of the condenser Condenser The condenser located behind the back cover should be inspected every 30 days and cleaned if necessary Failure to keep the condenser clean will cause a loss in condenser unit efficiency Per