Home
Perle Systems C-10GT-XFPH User's Manual
Contents
1. Green blinking slowly the module is in test or loopback mode Red blinking s owly while in Test mode indicates an error within the last second Red Solid During power up hardware error detected Red Blinking quickly Error detected See LK1 LK2 Error Codes Perle C CM 10GT Media Modules Installation Guide 11 LK1 Port 1 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through Blinking one second on 3 seconds off the maximum specified operating temperature within the inserted module has been exceeded Off No fiber link present LK2 Port 2 Activity On Copper link present Blinking quickly Copper link present and receiving data Blinking slowly The copper link has been taken down as a result of Smart Link Pass Through Blinking one second on 3 seconds off the maximum specified operating temperature within the inserted module has been exceeded Off No copper link present LK1 LK2 Error Codes LK1 LK2 Meaning Off Off Incompatible SFP or XFP Off On Power Budget exceeded XFP s requesting more power than specified port rating communicate with module On Off SFP or XFP communication error C CM 10GT unable to On On Internal Error Perle C CM 10GT Media Modules Installation Guide 12 Troubleshooting General v Ensure that
2. Perle 10GT Media Converter Modules Installation Guide C 10GT SFP CM 10GT SFP C 10GT XFPH CM 10GT XFPH P N 5500337 10 Overview This document contains instructions necessary for the installation and operation of the Perle C CM 10GT Media Converter modules These models are used in conjunction with a Perle Media Converter chassis Each module contains one pluggable transceiver port that permits insertion of a SFP or a XFP fiber module and one integrated RJ 45 copper port These media converter modules can use either Perle Systems or third party MSA compatible 10G XFP or SFP modules including support for the following standards 10GBase SR 10GBase LR 10GBase ER 10GBase LRM and 10GBase ZR The C CM 10GT SPF supports one low power transceiver SFP whereas the C CM 10GT XFPH supports one high power transceiver XFP up to power level 4 These modules take two slots within a Perle Media Converter chassis The C model modules are the unmanaged modules and the CM models are the managed modules For information on the management options of the CM modules refer to the Perle MCR MGT User s Guide that came with your Perle Management Module All combination of modules within the chassis cannot exceed the chassis power input consumption The full power consumption for Perle Media Converter chassis can be found on the Perle website Model Port 1 Port 2 Type C 10GT SFP SFP RJ 45 unmanaged CM 10GT SFP SFP
3. Alert Test Mode Port 4 Energy Efficient Ethernet EEE 5 Not Used Perle C CM 10GT Media Modules Installation Guide 4 DIP Switch Settings The DIP switches are located on the module Note Switch changes made when the module is powered up take effect immediately and will result in a link reset on both ports Operating Mode Switch 1 Switch Position Mode Up default Data Down Test Data In Data mode data will flow between the fiber connection and the copper connection Test Test Mode is used to run diagnostics enable loopback and for running the Built In Link Tests Note The Operation Mode Switch 1 affects the function of DIP Switches 2 and 3 when in Test mode Link Mode Switch 2 Data Mode Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the link state on one port connection is directly reflected through the media converter to the other port connection If link is lost on one of the connections then the other link will be brought down by the media converter Standard Mode In this mode the links can be brought up and down independently of each other A loss of link on either connection can occur without affecting the other fiber connection Perle C CM 10GT Media Modules Installation Guide 5 Test Function Switch 2 Test Mode Switch Position Type Up default Bui
4. the SFP or XFP module is inserted correctly into the transceiver port vy Ensure that the copper cabling RJ 45 meets Ethernet copper cabling requirements See Copper Cable Requirements in this guide No connectivity If unable to get full connectivity with all DIP switches in the UP position these procedures can be used for troubleshooting Built In Link Test The Built In Link Test requires two 10GBaseT modules converters Choose one side of the link to generate the test data master side and one side to receive and analyse the test data slave side 1 Set Switch 1 down and Switch 2 to the Up position Built In Link Test on the master side 2 The master side automatically sends test data to the slave side 3 The slave side analyses the received test data and sends its own test data plus a diagnostic code back to the master side 4 Ifthe PWR LED on the master side blinks red then this connection may require further testing 5 Ifthe PWR LED on the master side blinks green after several seconds of testing then the SPF XFP link is passing the Built In Link Test 6 The Built in Link Test continues to run until Switch 1 on the master side is set back to Data mode Perle C CM 10GT Media Modules Installation Guide 13 Loopback Test This mode is not used in conjunction with BILT 1 If either media converter module is not a Perle 10GT module then you need to set loopback mode on one of the media converter modules S
5. to 3 048 m 10 000 ft Operating Altitude SFP and XFPH Feature Set e MSA Compliant SFP SFP e MSA complaint Class 1 2 3 and 4 XFP modules for the C CM 10GT XFPH e 1G copper modules e 1G fiber modules e SFP supports CX1 modules e XFP supports CX4 modules Fiber Cabling Requirements MM 50 125 microns 62 5 125 microns SM 9 125 microns Copper Cable Requirements e Category 6A e Straight through or Ethernet crossover Perle C CM 10GT Media Modules Installation Guide 15 Compliance Information FCC This product has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in acommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this Guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Contacting Technical Support Contact information for th
6. Events 1 Media Converter Module loses fiber connection RX 2 Media Converter Module notifies the remote Media Converter Module that there is a fault on the Link 3 Media Converter Module B detects loss of fiber link on receiver RX 4 Media Converter Module B turns off transmitter TX Port Selection Switch 3 Test Mode Switch Position Port Up default 1 Down 2 When Loopback mode is selected Switch 1 and Switch 2 down this switch specifies which port to enable loopback mode on Perle C CM 10GT Media Modules Installation Guide EEE Energy Efficient Ethernet Switch Position Mode Up default Enabled Down Disabled Enabled When enabled the media converter will auto negotiate this capability with the attached EEE compliant devices servers Disabled The media converter will not auto negotiate this capability with the attached EEE compliant devices servers Installing Modules 1 Set any jumpers and or DIP switches on the module to the desired operating mode Gently slide the module into the slot until it becomes flush with the front of the chassis Light pressure may be needed to seat the module Do not force the module as you might damage the module If there is resistance remove the module and check the module s backplane connector for damage to the pins If the module s backplane connector is not damaged try to reinsert the module ag
7. RJ 45 managed C 10GT XFPH XFP RJ 45 unmanaged CM 10GT XFPH XFP RJ 45 managed Note The C CM 10GT SFP media converter module can operate as a 1G media converter module if a 1G fiber transceiver has been inserted into the SFP transceiver port Visit Perle s web site for the most up to date Installation guides models and specifications hitp www perle com Perle C CM 10GT Media Modules Installation Guide 2 Getting to know your C CM 10GT Media Converter Your C CM 10GT Media Converter package consists of the following items e C CM 10GT module with one transceiver port SFP or XFP and one RJ 45 copper port e This guide Front View 4 _ Captive Retainer i Screw LEDs Port 1 SFP XFP Port 2 RJ 45 UT LEE Perle C CM 10GT Media Modules Installation Guide Installation The default switch setting all switches in the UP position will work for most installations The Auto Jumper is set to Auto for Ethernet Auto detection These are the steps required to configure the Perle C CM 10GT module Set the Auto Jumper switch optional Set the DIP switch settings optional Install the module into the chassis See Installing Modules Insert the appropriate SFP XFP into the transceiver port Connect the fiber cable Connect the RJ 45 copper cable See Copper Cable Requirements OO GIN C CM 10GT SFP or C CM 10GT XFPH 1 Operating Mode 2 Link Mode Test Type 3 Fiber Fault
8. ain Tighten the Captive retainer screw to ensure the module is locked in place Caution Observe electrostatic discharge precautions when installing or removing the module s from the Chassis Failure to observe this caution could result in damage to the module s and or chassis Perle C CM 10GT Media Modules Installation Guide 9 AUTO Config Jumper CM models only The Auto Config jumper is located on the outer edge at the midpoint of the module Jumper the top and middle pin to select Auto mode Jumper the middle and bottom pin to select SW mode AUTO When set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this configuration as its running configuration If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration SW When set to SW Switch the module will at power up read the settings of the DIP Switches and use those as its running configuration It will ignore any configuration information in its flash memory NOTE The default jumper setting is AUTO Perle C CM 10GT Media Modules Installation Guide 10 Operation Status LED The Perle C CM 10GT Media converters modules have three status LEDs located on the faceplate of the module PWR Power Test Green On Power is on and the module is in normal operation mode
9. e Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made via this web page www perle com support services support request shtml Warranty Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage Details can be found at http www perle com support_services warranty shtml Copyright 2013 Perle Systems Limited All rights reserved No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited Perle C CM 10GT Media Modules Installation Guide 16
10. ee the User s Guide that came with that media converter module 2 Use an alternative way to generate data to the unit set in loopback mode Data received on the receiver RX will be looped back to the transmitter TX connection Use a third party application to analyse the received data Module Temperature Protection All C CM 10GT modules come equipped with module temperature protection Should an inserted SFP or XFP module operate above its specified maximum operating temperature the C CM 10GT will reduce the power to that module The C CM 10GT will continue to monitor the modules temperature until the temperature is below the maximum operating temperature and then the C CM 10GT will return the module to normal operating mode Perle C CM 10GT Media Modules Installation Guide 14 Technical Specifications Power Input Consumption 9 30VDC SFP 1 1A Max 0 8A at 12VDC Operating Temperature 0C 50C 32F 122F Storage Temperature 250 70 13F 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Power Input Consumption 9 30VDC XFP 1 7A Max 1 25A at 12VDC Operating Temperature 40 75 40F 167 F Storage Temperature 40 85 40F 185F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Up
11. lt In Link Test BILT Down Loopback Built In Link Test Set Switch 2 to the Up position for the C CM 10GT media converter module to initiate the Built In Link Test on port 1 These tests consist of the media converter module generating test patterns to be sent out on port 1 to the remote media converter module If the remote media converter module is also a compatible 10GBaseT media converter module then the remote media converter module will automatically be put into test mode Note The BILT can operate on 10G modules This feature can also be used with Perle S 10G media converters Loopback If Switch 2 is down the specified port will be forced into loopback mode switch 3 determines the port number Data received on the receiver RX will be looped back to the transmitter TX connection This mode is not used in conjunction with BILT It can be used when other data generation methods are used Illustration of the Built In Link Test Local C CM Remote C CM Module Module Built In Link Test Local C CM 10GT Configuration Test Mode Switch 1 Down Test Function Switch 2 Up Remote C CM 10GT Configuration All switches in the Up position Perle C CM 10GT Media Modules Installation Guide 6 Sequence of Events 1 The Local C CM 10GT media converter module sends the Remote C CM 10GT media converter module a signal to go into test mode The Remote C CM 10GT media converter module
12. turns on test mode Built In Link Test data is sent from the Local C CM 10GT media converter module to the Remote C CM 10GT media converter module The Remote C CM 10GT media converter module analyses the received test data and sends its own test data plus a diagnostic code back to the Local C CM media converter module If the PWR LED on the Local C CM media converter module blinks red this connection may require further testing The PWR LED should flash green to indicate that there have been no errors in the last second The Built in Link Test continues to run until Switch 1 on the Local C CM 10GT media converter module is set to Data mode Fiber Fault Alert Switch 3 Data Mode Switch Position Mode Up default Enabled Down Disabled Enabled If the media converter module detects a loss of signal on the fiber port the media converter module notifies the link partner on that same port that an error condition exists by bringing down the link Disabled The media converter module will not monitor for fiber fault Perle C CM 10GT Media Modules Installation Guide 7 Fiber Fault Alert Sample Config Media Converter Module Media Converter Module 9 6 oO 6 s Copper Port Copper Port Fiber Port Sai Media Converter Module A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter Module B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of
Download Pdf Manuals
Related Search
Related Contents
"取扱説明書" MANUAL DE INSTRUCCIONES TABLE OF CONTENTS Lire attentivement le mode d`emploi ainsi que les consignes IT6100B series programming manual CARDIOVIT AT-101 Télé Appareil ECG portable 12 pistes avec Manual de instrucciones para parquets DI LEGNO® aceitados Renesas Embedded Application Programming Interface User`s Copyright © All rights reserved.