Home
Pentair Pool-Spa Control System Time Master User's Manual
Contents
1. SETTING THE CLOCK TIME CONTROL 1 Push PROGRAM button until no flashing 7 PROGRAM zi number appears on the right of the display 10 58i wos E The clock is now in time mode Nees E 2 Push HOURS and MINUTES buttons until correct time of day is displayed NOTE Pay attention to the AM PM indicator FATE ONE SPA AUXI DELAY CANCEL PROGRAMMING There are six possible programs during a 24 hour period for turning the pool equipment ON or OFF More than one piece of equipment may be programmed ON or OFF at the same time 1 Push PROGRAM button once A1 P 1st Program will flash on the right of the display The clock is now in program mode 2 Enter desired program time by pushing the HOURS and MINUTES buttons In program mode minutes are advanced in ten minute increments Payattentionto the AM PM indicator 3 Push FILTER CLNR SPA or AUX1 button to program equipment ON or OFF The presence of a flag above each button indicates that the equipment is pro grammed ON The absence of a flag indicates OFF 4 Repeat the preceding sequence for the remaining five programs 2P 6P NOTE Each time change requires a new program 5 After programming push PROGRAM button to retum clock to time mode If this is forgotten after four minutes the clock will automatically return to time mode 3 If the spa is constructed in concrete and optional Spa side Remote Control model SS 100 is to be used s
2. TIME CONTROL naa 4 400 aH HOURS E MINUTES ail CLNR SPA AUXI FATER DELAY CANCEL TIME CONTROL rrocram i 7 400 sP HOURS gt MINUTES E FATHA CLNR SPA AUXI DELAY CANCEL TIME CONTROL PROGRAM A 12430 wous E MINUTES E HATER CUNR SPA AUXI DELAY CANCEL SAMPLE PROGRAM In the adjacent examples 1P The first program will turn on the filter at 7 40 am 2P At 10 00 am the filter pump will continue to run and the pool cleaner will turn on 3P The pool cleaner will turn off at 12 30 pm and valves will rotate so that filter pump cir culates water through the spa 4P At 4 00 pm valves will rotate back to pool circulation and filter pump will turn off after 4 minute delay 5P The fifth program will turn on AUX 1 pool light at 7 00 pm 6P AUX 1 pool light will be turned off at 12 30 am UNUSED PROGRAMS If your personal program does not use all six programs unused programs must be turned off 1 Push PROGRAM button unti unused pro gram is displayed 2 Push and hold down MINUTES and HOURS buttons simultaneously 3 First release HOURS and then MINUTES button OFF will now be displayed along with flashing program number 4 To eliminate OFF push HOURS button once NOTE Equipment can be manually turned ON or OFF by pushing appropriate buttons while clock is in time mode LX 10 SERVICE CENTER REMOTE SWITCHES a Zz oO y x
3. a m LOW VOLTAGE WIKING DIAGRAM PROGRAM SWIICH uio RED SWITCH 1 YEL SWITCH 2 GRN SWITCH 3 oO g x x D D qd LVS 3 BLK GND BLU SWITCH 1 yr BLK SWITCH 2 GRN SWITCH 3 24 GND HTR Sol FLTR CLNR VLVS AUXI AUX2 AUX3 SPA REMI REM2 REM3 FRZ HTR Nn 3 222 WHT LAMP 2 y BLK LAMP 1 T 2 lt BLK LAMP 3 RED m 24 REMOTE LAMPS EEFE GAS HEATER GAS VALVE CONTROL Do not untwist pairs It is neccessary to retain wires in pairs so that appropriate connections can be identified FREEZE SENSOR WATER SENSOR THERMOSTAT HIGH VOLTAGE RELAYS FILTER PUMP POOL CLEANER AUXILIARY 1 OPERATING INSTRUCTIONS GENERAL CONTROL FEATURES FILTER PUMP OFF DELAY This causes the filter pump to run an additional 4 minutes every time it is turned off The purpose of this is to protect the gas heater and plumbing from possible scale build up and thermal stress These occur when residual heat in the gas heater is not allowed to dissipate after heater is turned off POOL CLEANER ON DELAY Every time the pool cleaner pump is turned on this circuit prevents it from running until 4 minutes have passed This protects the pump from damage caused by air in the water lines that may have entered into the plumbing since it was last used TIME CONTROL EQUIPMENT BUTTON FUNCTIO
4. receipt postage prepaid to COMPOOL CORPORATION 599 Fairchild Drive Mountain View California 94043 2217 599 Fairchild Drive Mountain View California 94043 2217 415 964 2201 Computerized Pool Systems TREN INSTITUTE INSTALLATION INSTRUCTIONS TIME MASTER POOL SPA CONTROL SYSTEM IMPORTANT SAFETY PRECAUTIONS All wiring must be performed by a qualified electrician Basic safety precautions and local codes should be observed when installing and using this electrical equipment READ AND FOLLOW ALL INSTRUCTIONS EQUIPMENT LOCATION All electrical equipment must be located five feet or more from pool or spa with the exception of the optional Spa side Remote Control 1 LX 10 Service Center at the equipment pad area 2 Time Master inside house or other weather protected area 3 VOR 24 Vaive Operators at three port valves 4 WTS 5L Waiter Sensor at filter pump 5 SS 100 Spa side Remote Control optiona at spa site LOW VOLTAGE CABLES Determine lengths of 22AWG low voltage cable needed between equipment 1 6pair cable from Time Master to LX 10 Service Center 2 2 conductor cable from gas heater to LX 10 Service Center 3 Water Sensor is provided with 10 feet of 2 conductor cable 4 Valve Operators are provided with 15 feet of 3 conductor cable 5 Spa side Remote Control is provided with 100 feet of 4 conductor cable Remote Control is also available with 50 150 or 200 feet of cable Install cable
5. Button on the Time Master Controller will be redundant Flag and Status Light may stiil be turned ON but display is meaningless Adjust U10 Program Switch located at the bottom of the printed circuit board so that Switches 4 5 and 6 are programmed ON and Switches 1 2 3 and 7 are programmed OFF Modify low voltage wiring as follows Disconnect black wire of blk yel pair from CLNR screw terminal on LX 10 printed circuit board and subsitute with yellow wire from SS 100 Spa side Remote SPA WATERFALL CONTROL For systems where spa water level is higher than that of the pool a Spa Waterfall Control model RLY WTRFL may be added AUX1 Button at the Time Master or an optional Remote Control switch can be used to rotate the return valve operator to SPA position while system is in POOL mode thus creating an overflow waterfall effect from spa to pool This effect will cease whenever the system is in SPA mode Install RLY WTREL in accordance with instructions provided ELECTRIC HEATER CONTROL For systems which utilize a heat pump or electric heater in lieu of a gas heater a Relay Kit model RLY LX should be added at the LX 10 Install RLY LX in accordance with instructions provided and plug into ELEC HTR relay socket on printed circuit board The power relay is capable of controlling a heat pump an electric heater rated up to 3KVA or the magnetic contactor of a larger electric heater FREEZE SENSOR A Recirculating Freeze Senso
6. LIMITED WARRANTY Compool Corporation warrants to the purchaser of this control system for the period of one year from the date of original purchase for use that any defective product proved to be caused by faulty workmanship or faulty material will be repaired or replaced at Compoo s option for no charge providing the product is returned to Compoo with all transportation charges prepaid First Ninety Days During the first ninety days after installation if any Compoo control shall be found to be defective due solely to faulty material and workmanship Compool Corporation will additionally cover the reasonable replacement cost charged by an authorized service company After Ninety Days Between the ninety first day and the end of the first year after installation no allowances will be made for labor for the removal or reinstallation of any so claimed defective products This warranty covers the Time Master Controller LX 10 Service Center VOR 24 Vaive Operators and optional Remote Controls including all components and parts It does not include Valves or Sensors It extends to the first retail purchaser and any subsequent owners of the system This limited warranty applies only to controls which have been installed and maintained in strict accordance with installation and operating instructions provided by Compool Corporation using installation hardware supplied and or recommended in writing by Compool and to controls which have been co
7. NS FILTER Turns filter pump ON and circulates POOL water CLNR Turns filter and cleaner pumps ON Cleaner delayed 4 minutes SPA Turns filter pump ON and circulates SPA water Allows heater to operate Overrides CLNR key and turns pool cleaner pump OFF even if CLNR flag is present AUX1 Turns electrically controlled function ON lights jets etc TEMPERATURE CONTROL WATER TEMPERATURE Display Pool temperature is displayed when the pool is operating spa temperature when the spa is operating If filter pump is off display may be meaningless THERMOSTAT Desired pool or spa temperature is set here HEATER CONTROL SWITCH POSITIONS POOL Allows heating of pool to the preset temperature level SPA Allows heating of spa to the preset temperature level OFF Allows no heating HEATER ON Light When lit indicates that heater is on STATUS DISPLAY The presence of a light next to an equipment label indicates that it is ON The absence of a light indicates OFF DELAY CANCEL BUTTON FUNCTIONS FILTER To override the Filter Delay Circuit press CANCEL OFF DELAY button Provided that there is no flag present at either FILTER CLNR or SPA buttons the filter pump will shut off immediately CLNR To override the Cleaner Delay Circuit press CANCEL ON DELAY button Provided that there is a flag present at the CLNR button the pool cleaner pump will start immediately If SPA is on CLNR is inoperative
8. Place cable in plastic or metailic conduit where it runs underground ihrough concrete etc NOTE Never install low voltage cable and high voltage wires in the same conduit A minimum distance of 12 must be maintained between parallel runs of low voltage cable and AC current carrying wires 22AWG cable is available from Compool Corporation PLUMBING Follow recommended schematic see next page for location of three port valves 2 dia plumbing is advised to ensure optimum filter pump efficiency 1 AY spa makeup line incorporating a 2 manual gate or ball valve and for elevated spas a 2 check valve should be provided around the return valve see schematic This enables clean water to be circulated to the spa while the system is in POOL mode 2 Spa should be at or above the level of the pool If spa is attached to pool provide a dam between the two bodies of water to allow spa overflow into pool If spa is not attached to pool an overflow sufficient in size to carry full pumpflow must be installed at water level in the spa HYDRAULIC AND ELECTRICAL SCHEMATIC POOL CLEANER SENSOR TIME CONTROL J 46 PROGRAM M HOURS E gt ms E FAHR CLNR SPA AUXI DELAY CANCEL TIME CONTROL reoceam i 10500 7 wus E MINUTES A FRIJER CINR SPA MUA DELAY CANCEL TIME CONTROL rrocram B 12130 nous E gt MINUIES Ei FATER CLNR SPA AUX DELAY CANCEL
9. an be unplugged from printed circuit board without disconnecting wires VALVE OPERATORS Mount Valve Operators model VOR 24 to three port valves in accordance with instructions printed on box Plug cables into side of each Valve Operator and run cables t gt low voltage compart ment of LX 10 Service Center Plug other end of cables into appropriate valve socket on printed circuit board intake suction valve to INT valve socket and return valve to RET valve socket WATER SENSOR Select a convenient location to mount Water Sensor model WTS 5L in the plumbing system at the filter pump Ensure that this locationis nogreater than 10 feet from LX 10 Service Center otherwise cable will need to be extended Disconnect Water Sensor from WTS and WTS terminals on printed circuit board of Time Master Remove clamp kit from behind service panel in right side compartment of LX 10 and install Sensor in accordance with instructions Cautior Overtighting of clamp can cause deformation of O ring seal Run cable from Sensor location to low voltage compartment of LX 10 Cut off excess cable if necessary Strip insulation and connect to black green pair of 6pair cable in accordance with wiring diagram located inside LX 10 cover Pay special attention to polarity of Sensor as indicated by color coding GAS HEATER Inside the heater interrupt wire between thermostat and gas valve and connect 2 com ductor cable with wire nuts in accordance with wiri
10. d make connections to REMOTE SWITCHES screw terminals in accordance with wiring diagram located inside enclosure cover Connect black wire switch common to GND terminal and connect red yellow and green wires to desired terminal for SPA AUX 1 AUX 2 AUX3 and AUX 4 Note for the convenience of the serviceman the screw terminal can be unplugged from printed circuit board without disconnecting wires INDOOR REMOTE CONTROL OPTIONAL Select a convenient location inside the house or other weather protected area to mount the LVS 3 3 button indoor remote or LVS 3TR 3 button indoor remote w digital temperature display Install in accordance with instructions provided At the LX 10 low voltage com partment strip jacket of cable 6 to identify the twistec pairs and assure correct connections Strip insulation of each wire 4 and connect to appropriate screw terminals at REMOTE SWITCHES and REMOTE LAMPS terminal 1 Select any three circuits from SPA AUX 1 AUX 2 AUX 3 and AUX 4 2 Number the circuits 1 2 and 3 3 Make sure that the corresponding SW and LMP wires from the Indoor Remote are connected to the appropriate circuit at the LX 10 REMOTE SWITCHES and REMOTE LAMPS terminal NOTE If the LVS 3TR is being used install the second Water Sensor included in accordance with previous instructions and run cable to LX 10 low voltage com partment Wire nut to yellow black pair of wires from LVS 3TR cable red connects to yel
11. elect a convenient location in the deck or above water level in the spa wall SS 100 should not be submerged by the spa water install a6 to12 length of 112 pvc pipe at this location to provide a receptable for SS 100 This pipe should be level and protrude beyond the finished surface of spa It lt can be cut back at a later date Connect 1 coupling and reducing bushing for either 2 or conduit and provide conduit as necessary to location of LX 10 Service Center Do not install Outdoor Remote Control until spa construction is completed LX 10 SERVICE CENTER Select a convenient location at the equipment pad area to mount LX 10 Service Center Ensure that the location is greater than 5 feet from the waters edge and no further than 15 feet from the three port valves Mount the LX 10 ona flat surface using appropriate screws through the three external mounting points located on the side of the enclosure Do not drill and mount from inside the enclosure Install to provide drainage of compartment for electrical components All low voltage connections are made to printed circuit board located behind hinged faceplate in left side compartment Strip jacket of 6pair cable 6 to identify the twisted pairs and assure correct com nections Strip insulation of each wire 14 and connect to screw terminal in accordance with wiring diagram located on inside of enclosure cover NOTE For the convenience of the serviceman the screw terminal c
12. low green connects to black in accordance with wiring diagram located inside LVS 3TR A Label Set for indoor remote controls model LBL 100 is available from Compool Corporation This set of 100 different labels provides custom equip ment identification at each remote control button SYSTEM START UP Apply power to the system At the Time Master pull out battery shield to activate back up battery and push HOURS button unti digital readout is displayed At the LX 10 Service center turn SYSTEM CONTROL Switch to SERVICE position and FLOW CONTROL Switch to POOL position Check that Valve Operators have rotated to correct positions To adjust position of any valve simply reverse the cable plug on the side of Valve Operator At the LX 10 Service Center turn MANUAL CONTROL Switches to ON positions and check that all equipment is operating Turn OUTDOOR REMOTES Switch to ON position and check that optional Spa side Remote Control is functioning correctly Turn MANUAL CONTROL Switches to OFF positions The system is now ready to be operated as desired SYSTEM OPTIONS TWO SPEED PUMP CONTROL If the system is equipped with a two speed filter pump a Dual Speed Relay Kit model RLY LXD should be added at the LX 10 in accordance with installation instructions provided The system will automatically run the filter pump in high speed under any of the following conditions 1 Whenever the heater is on 2 Whenever p
13. ng diagram which is located inside LX 10 cover Do not disconnect high limit and pressure switches Run cable to LX 10 low voltage compartment Strip insulation 4 and connect to HTR terminals on printed circuit board AUXILIARY EQUIPMENT CONTROL OPTIONAL The standard Time Master system is provided with 3 power relays for controlling filter pump pool cleaner and auxiliary 1 pool light It is possible to control additional equipment such as a jet pump air blower spa light etc by installing extra relay kits model RLY LX The LX 10 Service Center will accommodate a total of 7 relays Note Further relays may be controlled by an addi tional Power Center model LX 36 Install RLY LX Relay Kit at the LX 10 in accordance with instructions provided SPA SIDE REMOTE CONTROL OPTIONAL When the spa construction is completed install optional Spa side Remote Control mode SS 100 in accordance with instructions provided 1 Cut back the 14 dia pvc receptacle flush with spa wall finish or surface of deck 2 Making sure that screw threads are facing out glue adapter into receptacle using pvc cement 3 Thread cable through gasket and run through conduit to LX 10 low voltage compartment 4 Before installing SS 100 rotate 7 turns counterclockwise to avoid undue twisting of cable 5 Screw SS 100 into adapter and finger tighten Caution Do not use wrench 6 At the LX 10 cut off excess cable if necessary Strip insulation 14 an
14. nnected to the correct supply voltage This limited warranty does not apply to any controls which have been repaired or altered by anyone other than Compool or a person authorized by it or which have been subject to misuse neglect or accident or which have been damaged by wind freezing or other cause thing person or act of God or which have been subject to damage in transit during installation or by someone other than Compool Corporation or which have been damaged because of a defect in a component or part which is not part of the Compool Control System or upon which the serial number has been aitered effaced or removed This warranty gives you specific legal rights and you may also have other rights which vary from state to state Compool Corporation does not authorize any person to create any other obligation or liability in connection with Compool controls Compool Corporation makes no warranty of merchantability or fitness for any use Any implied warranty applicable to Compool controls is limited in duration to the duration of this written warranty Compoo Corporation shall not be liable for consequential or incidental damages resulting from breach of this written warranty or any implied warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of incidental or consequential damages may not apply to you To exercise this warranty send defective unit with copy of dated
15. oo cleaner is running 3 Whenever spa is running It is possible to eliminate one or more of these conditions by adjusting U11 Program Switch which is located at the top of the printed circuit board See RLY LXD installation instructions for details PROGRAMMABLE TWO SPEED PUMP CONTROL If the system is equipped with a two speed filter pump it is additionally possible to program the pump to run in high speed by using AUX 1 Program Button on the Time Master Controller However this feature will only operate when the filter pump is running Install RLY LXD as above Adjust U10 Program Switch located at the bottom of the printed circuit board so that Switches 1 3 and 6 are programmed ON and Switches 2 4 5 and 7 are programmed OFF ADDITIONAL VALVE CONTROL It is possible to add valve operators model VOR 24 to the system to actuate additional three port valves for pool cleaning or for a custom hydraulic feature such as a fountain waterfall second spa etc A total of three valve operators may be added Install Valve Module model MOD VLV1 at LX 10 low voltage compartment in accordance with instructions provided and connect valve operators accordingly ADDITIONAL REMOTE CONTROL IN LIEU OF CLEANER If the system does not utilize a separate pool cleaner pump itis possible to use the pool cleaner relay to activate an additional remote circuit This circuit is controlled by the Spa side Remote Control NOTE CLNR Program
16. quire additional relay kits model RLY LX Run wires from breakers to high voltage compartment of LX 10 and connect to LINE 1 and LINE 2 of relevant terminal blocks Connect pumps and other high voltage equipment to LOAD 1 and LOAD 2 terminals at relevant terminal blocks Each individual terminal block can be wired for either 115 or 230V AC A relay allocation chart is provided inside enclosure cover for the service man s convenience To reduce the risk of electric shock provide a continuous green insulated copper wire no smaller than 12 AWG between grounding bus of LX 10 and grounding terminal of electrical supply panel Awire connector is provided for bonding to local ground points To further reduce the risk of electric shock this connector should be bonded with a 8 AWG copper wire to any metal ladders water pipes or other metal within 5 feet of pool or spa TIME MASTER Select a convenient location inside the house or other weather protected area to mount Time Master Controller Unscrew faceplate from enclosure and use enclosure as a template to mark and cut hole 81 2 wide by 4 2 high in sheetrock or wall paneling Using the mounting clips provided instali enclosure into wall Strip jacket of 6pair cable 6 to identify the twisted pairs and assure correct connections Strip insulation of each wire and connect to screw terminal in accordance with wiring dia gram located inside enclosure Caution Do not unt
17. r model FPS C may be added to the system It protects the plumbing and equipment from possible freeze damage by running the filter pump whenever the temperature falls to approx 41 F Install FPS C in accordance with instructions provided An Auxiliary Pump Freeze Sensor model FPS AUX may also be added to the system to activate auxiliary equipment such as jet pump during potential freezing conditions Install FPS AUX in accordance with instructions provided CUSTOM OPTIONS Additional custom options are also available These options however require custom adjustments at the factory Consult Compooi Corporation for details SAVE THESE INSTRUCTIONS HIGH VOLTAGE WIRING All high voltage connections are made to terminal blocks which are located be hind service panel in right side compartment of LX 10 Service Center A high voltage wiring label is located adjacent to terminal blocks Knock out holes are provided on bottom of enclosure for conduit mounting Provide a separate circuit breaker if possible to power the system Either 115VAC or 230VAC can be used System draws less than 1 amp Run wires from circuit breaker to high voltage compartment of LX 10 and connect to top terminal block which is marked SYSTEM POWER Install2 jumpers for 115V or 1 jumper for230V wiring according to wiring label Provide independent circuit breakers if possible for FLTR CLNR and AUX 1 Note AUX 2 AUX 3 and AUX 4 are optional and re
18. wist pairs It is necessary to retain wires in pairs so that appropriate connec tions can be identified Note For the convenience of the serviceman screw terminal can be unplugged from printed circuit board without disconnecting wires Mount faceplate to enclosure
Download Pdf Manuals
Related Search
Related Contents
Samsung ST100 manual de utilizador Samsung GT-E1080W Instrukcja obsługi Untitled Télécharger - CRDP de Montpellier Kicker CX1200.1 Stereo Amplifier User Manual 宮城県消防学校移転整備事業 入札説明書 平成 20 年 4 Copyright © All rights reserved.
Failed to retrieve file