Home
Pentair Illuminator PG2000 User's Manual
Contents
1. debris etc a is kept clear of intake vents on back of the unit in order to allow for proper air flow Do not install PG2000 Illuminator in an underground utility box o similar appliance Damage to the unit due to blocked air vents or poor ventilation will void the warranty POWER COLOR POWER COLOR OFF OFF ON ON Replacing the Bulb 1 Turn power to unit off REMOTE SWITCH CONTROL RF2000 WIRELESS CONTROL Turn off power before changing bulb Failure to turn off power may lead to severe electrical shock which can result in death or severe injury SF ey POWER COLOR POWER COLOR 2 Remove two screws securing outer body and lift outer body straight up AWARNING Bulb socket and reflector are extremely hot during and following operation Allow sufficient time for cooling before touching them or you may suffer severe burns 3 Remove screws 3 at bottom of socket bracket see Figure 1 and separate socket bracket assembly from reflector Remove bulb from socket and insert new bulb Be sure not to touch the glass of the bulb ACAUTION Do not touch the bulb with your bare fingers fingerprints can actually cause the bulb to overheat and crack Handle the bulb using sheath provided in packaging 4 Reassemble socket bracket and make sure bulb is centered in reflector 5 Replace outer body and secure with two screws a Figure P N 840263 2 Rev C 5 15 09 PG2000 Synchronization Procedures
2. with SAm light Listed below are the procedures to follow if you have a SAm underwater color light installed in your pool or spa and wish to synchronize your fiber optics with SAm NOTE There may be slight color variations between the SAm and PG2000 depending on the application These variations are caused by differences in initial light intensity and attenuation of the water and or reflective surfaces i e pool wall coloring In order for instructions to work you must have P N 840242 7 Color Electronic Synchronized PG2000 all other part numbers must use visual synchronization method Synchronization Start Conditions 1 SAm is ON and colorwheel is stopped on ANY color including white 2 PG2000 power is ON and the colorwheel is OFF Synchronization Procedure 1 Simultaneously toggle SAm OFF ON and turn the PG2000 colorwheel ON 2 Allow about 1 2 minutes for colors to synchronize Enjoy 3 To stop both lights on the same color simultaneously toggle SAm OFF ON and turn the PG2000 colorwheel OFF Visual Synchronization Method for use with P N 840241 only 1 Turn SAm ON colorwheel is stopped on ANY color including white 2 Turn PG2000 ON and colorwheel ON 3 When PG2000 transitions between purple and magenta toggle SAm OFF ON 4 To stop both lights on the same color simultaneously toggle SAm off and on while turning the PG2000 colorwheel off Troubleshooting If the PG200
3. 0 does not come on at all e Make sure the power switch is on see switch position diagram On Auto Remote Control Compool Jandy make sure the proper auxiliary is turned on The PG2000 should always operate in manual mode no matter what type of control system is installed e Check that the circuit breaker is not tripped e Check the incoming voltage at the PG2000 to verify power supply e Check the fuse es inside the unit Replace if fuse is open If there is no light e Check that the bulb is in place securely in the socket Ifyou can hear the fan running the lamp has probably failed Replace lamp If the fan runs but the light cycles on and off e Check the vents of obstructions There must be adequate air flow or PG2000 will overheat and begin to cycle e Ifthe unit is operating in direct sunlight during a very hot day it may exceed the recommended operating temperature and cycle on and off This protects the end of the fiber optic cables from damage and is normal If the light comes on but the fan is not running e Turn off PG2000 immediately and check for obstructions in the fan e DO NOT continue to operate PG2000 without the fan running The excess heat can damage the fiber optic cable Colors do not change e Make sure the colorwheel power is on On Auto Control Compool Jandy make sure the proper auxiliary is turned on e Remove the body and check the colorwheel for obstructions or debris that m
4. PG2000 Owner s Manual Specifications Electrical 120 VAC 60 Hz Operatingload 2 amps Material High Strength Plastic Weight 20 Ibs Lamp 150 Watt Metal Halide Lamp Life 6000 hours Restrike time 2 3 minutes Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 800 831 7133 919 566 8000 is 10951 West Los Angeles Ave Moorpark CA 93021 800 831 7133 805 553 5000 Pentair Water Visit us on the Internet at www pentairpool com or www staritepool com Pool and Spa Rev C 5 15 09 1 P N 840263 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOWALL INSTRUCTIONS BEFORE OPERATING SYSTEM Operating the PG2000 Refer to the toggle switch position diagram below for the appropriate switch positions for your particular installation The switches are located on the lower right side of the unit The PG2000 should always operate in manual mode no matter what type of control system is installed NOTE When cycling system off then back on it may take up to 3 4 minutes before the lamp restrikes or comes back on The lamp must cool down before restriking All metal halide lamps have this characteristic and this is a normal function of the PG2000 ACAUTION PG2000 Illuminator must have good ventilation to operate properly Blockage of air flow or air intake will shorten the bulb life and could TOGGLE SWITCH POSITIONS damage the unit Make sure foliage grass groundcover yard
5. ight be interfering with the rotation of the color wheel TROUBLESHOOTING NOTE If none of the above suggestions solve your particular problem contact your pool contractor or Pentair Water Pool and Spa Inc s Customer Service hotline at 800 831 7133 Monday through Friday 7 30 a m 4 30 p m Rev C 5 15 09 3 P N 840263 SAVE THESE INSTRUCTIONS Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 800 831 7133 919 566 8000 gt Pentair Water 10951 West Los Angeles Ave Moorpark CA 93021 800 831 7133 805 553 5000 Pool and Spa 2009 Pentair Water Pool and Spa Inc All rights reserved This document is subject to change without notice Trademarks and Disclaimers PG2000 SAm Compool and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others Protected by one or more of the following U S Patents and all corresponding foreign counterparts U S Pat No 5 802 227 5 825 954 5 680 496 6 002 216 P N 840263 4 Rev C 5 15 09