Pentair HP 1000 User's Manual

image

Contents

1. Chlorine A common pool spa water sanitizer available in several different forms of powder solid tablets liquid or gas Chlorine Tablets A common form of chlorine that is solid in na ture used in a chlorinator that is eroded by water rushing over these tablets making a solution to be slowly fed to the pool water Circuit Breaker An automatic switch that will shut the power off to an electrical device heater circulation pump when an over load or short occurs Located in the electrical supply panel in your home or near the associated equipment Circulation Pump An electric water pump that circulates water through the filter and other pool related equipment Usually con trolled by a timer Condensation Water that accumulates inside the heater due to the humidity in the air coming in contact with the colder freon piping in the evaporator coil This water will trickle out of the drain ports on the bottom of the heater Like sweat on a glass of ice water Control Devices Electronic devices used to manipulate the pool spa functions and equipment other than those manufactured into the heater itself Sometimes by remote control switches or sen sors Convection The transfer of heat from between two mediums of different temperatures in this case from hot to cold from warm pool to cooler outside air Compressor A reciprocating piston in a cylinder much like a car engine that compresses freon gas in a chamber before it is re
2. A pool water pump bond wire lug is in the same location The wire path from the knockout to the main contactor is about 3 feet Line side of the main contactor will be on the top The model number is located on a silver label on the front of the unit UNIT IDENTIFICATION MANDATORY BONDING TO POOL STEEL This is in addition to electrical ground External Make sure that the unit cabinet is bonded to the pool steel i ia pool steel Most codes require that the circulation pump be bonded 8 Solid as well You can connect at that point using at least a 6 gauge or larger solid copper wire Use the external bond Circulation lug on the cabinet to insure a good bond Bonding the unit to the pool steel will help reduce the chance of electrolysis also know as electrical corrosion A heater left un bonded may experience corrosion to the To Pool Steel metal water tubing inside the heater CAUTION IN SOME CASES WE HAVE SPECIFIED BETTER THAN N E C CODE THEREFORE THE MANUFACTURERS SPECIFICATION BECOMES THE CODE FOR THAT PARTICULAR UNIT NOTE TECHNICIANS SEE SEPARATE INSTALLATION MANUAL FOR EXACT DETAILS HOW TO GET SERVICE When you experience trouble with your unit you should follow these simple procedures before requesting service on your pool spa heat pump 1 You should follow all start up procedures as described in this booklet Without exception you should clean the filtering system thoroughly consult t
3. Pentair MiniMax Plus HP Because reliability matters most OWNERS OPERATION MANUAL WARNING FOR YOUR SAFETY READ BEFORE OPERATING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance may cause property damage personal injury or death Installation and service must be performed by a qualified technician or service agency Models MiniMax Plus HP 400 XLS400 MiniMax Plus HP 600 XLS600 MiniMax Plus HP 800 XLS800 MiniMax Plus HP 1000 XLS1000 MiniMax Plus HP 230 CP12 Part 471949 Revision C 2003 Pentair Pool Products Inc 1620 Hawkins Avenue Sanford NC 27330 10951 West Los Angeles Avenue Moorpark CA 93021 Note Specifications may change without notice Owners Operational Information Only Technicians See Separate Installation Manual OWNERS SECTION TABLE OF CONTENTS 1 OPERATIONAL INSTRUCTIONS sssscssessasssssserssossissssaseessssassvenssativesdsceosesssssocarssssenassoatssentsaa seeds 3 7 a Introduction amp Design Features b Heater Control Panels amp L E D Status Lights 2 START UP PROCEDURES isccssisossssisxssessnssioas ds aes e vvIVEPHNY UE Et cEEE HERE yE EPIO E EHFL EUR Y EXE PIUM FERE EIU EYE ERE 8 13 a Compressor Warm Up Time b Filter System Cleaning c Operational Description c Circulation Pump Timer
4. leased to the heat exchanger Commercial Pool A pool for public use or for the use of commu nity residents that are governed by state and local codes Usually larger than a residential pool with a larger capacity filtering sys tem running at a high rate of water flow Copper Piping The piping inside the unit as it was manufactured leading up to the heat exchanger Corrosion The dissolving of the metals in the heater due to chemi cal action Cover Used to cover the pool surface and prevent heat loss re ferred to as a blanket Cupronickel Metal Alloy A special metal blend copper and nickel that is corrosion resistant Cycle Referred to here as on and off repeatedly either the fan and or compressor D E Filter A filter type that uses diatomaceous earth powder as a filter media The D E is discharged with the debris via a valve that reverses flow through the filter This is referred to as back washing The D E must then be replaced in the filter Dealer As authorized by agreement with the factory to sell and install this particular brand of heat pump Defrost Control An internal device that will prevent the evapora tor coil from getting an ice build up when the outside air tempera ture drops below 36 degrees It will shut the compressor off but allow the fan to run until the air temperature increases 31 Down Line A reference that pertains to chlorinator placement and chemical application meaning to i
5. Chem Resistant Check Valve INTERNAL AUTOMATIC BYPASS The heat pump in equipped with a internal Automatic Bypass valve A variable rate spring valve is used to regulate the wa Free Flow Flexible Marine Grade ter flow through the heat ex Cupronickel Water Inlets changer Steady flow will be de Heat Exchanger livered over a wide range of flow Encased in Closed Cell Foam rates This automatic valve can handle a maximum flow rate of 90 gallons per minute The automatic valve will com pensate for flow loss due to nor mal filter debris accumulation or changes if flow due to valving and other conditions See chlorinator placement guidelines Automatic Bypass Valve OUT Variable Rate Self Adjusting up to 90 G P M 18 HIGH RATE WATER PUMPS EXCESSIVE FLOW BYPASS MANIFOLD FOR LARGE 2 H P PUMPS OR OVER 90 G P M If the pool circulation pump is over 2 HP OR if the total flow exceeds 90 GPM you will have to add the excessive flow valve as shown here Do not install a bypass valve that will completely shut off flow to the heater see shut down procedures Some larger water pumps may be restricted if the pipe size is not adequate therefore reducing its overall flow rate When determining if you need an excessive bypass valve one has to consider the hydraulic restriction of the filter valving amount of 90 fittings and the distance of pipe to the pool in the exist ing filtering system If you have a 2 HP water pum
6. 6 Keep the chlorinator lid o ring lubricated with sili cone grease Replace when needed No chemicals or chlorine Dear vu tablets in the skimmer rap Basket EE 1 Pressure Side Suction i ULT Pool Shell Side QH g a ae co RS x D Return I pp o IE a s ee f L 4 Tubing OUT Off Line Type Chlorinator i _ ADDING CHEMICALS CAUTION Absolutely no chemicals in the skimmer Do not place any chemicals in the skimmer throat Chlorine tablets placed in the skimmer will allow a concentrated solution of chlorine to pass through the heat exchanger causing damage 7 Do not place any chemicals in the pump lint trap cav ity or filter Make sure the lint trap basket is placed properly to prevent debris from clogging the heat ex changer 8 Do not over load chlorinator feeder cavity Exces sive amounts of chlorine tablets will increase the chance of migration of acetic concentrated chlorine to migrate to the heat exchanger causing damage 25 of maxi mum is suggested 9 When adding gas chlorine make sure that the pH does not drop below 7 4 Make sure that the total alkalinity does not drop below 90 p p m Gas chlorine is very ace tic 10 Do not isolate the heater from the water flow unless you have installed a drain plug to drain all the water from the heat exchanger and then blow out with pres surized air Stagnant water will corrod
7. F with very high humidity or high wind speed Make sure heater is installed with the required placement clearances for air flow and roof clearance Do not install indoors Make sure that your sprinklers do not spray on the heater in any way what so ever If ice forms on the outer coil shut the heater off and allow ice to thaw You may use water at low pressure to thaw ice build up on the outer coil shut the heater off when doing so Call the factory for advice Clean entire filtering system and or replace filter element Inspect amp clean pump impel ler Adjust all plumbing valves Repair suction air leaks grease pump lid o ring Replace filter Wrong filter pump pipe size Automatic pool vacuum causing restriction Thermostat not shutting unit off at 104 F Call your dealer for advise Call the fac tory for advise Clean entire filtering system and or replace filter element Inspect amp clean pump impel ler Adjust all plumbing valves Repair suction air leaks grease pump lid o ring Replace filter Wrong filter pump pipe size Automatic pool vacuum causing restriction Call your dealer for advise Call the fac tory for advise Control Ready light ON Water Press OK light ON T Stat On light ON Fan is not turning Unit will not start All control lights ON Fan is turning no cool air dis charging out the top of heater Unit is not heating Spa will not heat to maximum tem perature of 104 F or 3 Thermo
8. Treatment Adding a larger than normal dose of chlorine to the pool water to kill contaminates algae and to remove combined chlorine Short Cycle The act of the compressor going on and off without letting the refrigerant gas to settle Short Term Freeze When the outside air temperature drops below 36 degrees for a short period of time usually for only a few days or so but not part of a normal seasonal change where lower tem peratures are expected as a norm Sodium Hypochlorite A liquid form of chlorine Skimmer A housing mounted at the pool water level in the pool wall and deck that is used to capture debris as water is drawn into it The water is drawn in by the suction created by the circulation pump Skimmer Basket The strainer type debris catch inside the skim mer housing that keeps debris from clogging other related equip ment Skimmer Inlet The square opening right at the pool water level flush with the pool wall Skimmer Throat The main cavity of the skimmer where the skim mer basket is located Solar Panels A manifold placed on a roof top to collect heat from the sun and transfer it to the pool water being pumped through it Spa a smaller body of water using hotter water temperature and high pressure water flow mixed with air to create a therapy effect Sprinkler Heads Irrigation water distribution device placed in ar eas of the yard that broadcast water to the surrounding area Surge Tank Par
9. factory specification Clean and flush the evaporator coils to remove debris salt and mineral build up at least twice a year Clean more often if you live in a costal and or sandy environ ment Clean them with a mild soap and a very soft brush Do not use a pressurized garden hose The air handling compartment below the fan must be cleaned of debris regularly Contact an air conditioning con tractor for proper methods of cleaning the evaporator coils Remember to make sure the irrigation sprinkler system does not spray on the unit The fan motor should be oiled when the unit is serviced otherwise once per year or more if needed Coastal in stallation should oil the fan motor 4 times per year or 7 more depending on exposure PLUMBING amp WATER FLOW PLUMBING CONNECTIONS Filtered Water IN on the LEFT front Heated Water OUT on the RIGHT front The plumbing inlets are slip p v c pipe that will accept a 2 inch p v c glue fitting The pipe is left plain so you can adapt to your needs Use p v c cleaner to prime the fitting and pipe Use a quality medium body p v c glue FOR PUMPS UP TO 2 H P OR 90 G P M MAX SEE PAGE 19 FOR LARGER WATER PUMPS WATER IN L Warning WATER B No a In OUT Heater Skimmer Filter 1 PUMP 2 FILTER 3 HEATER 4 LOOP amp CHECK 5 CHLORINATOR L 6 RETURN TO POOL Chlorinator or Chemical Feeder Chlorinator Loop amp 2 lb
10. of the containment Injection In regard to feeding pool chemicals into the water flow in whatever fashion Installer Same as dealer person or company where the unit was purchased Internal Adjustments Any part or component inside the cabinet of the unit Lint Trap Basket A strainer type basket that collects debris and prevents such from being trapped in other equipment including the heat exchanger Liquid Chlorine Chlorine in a liquid form sodium hypochlorite Long Term Freeze When the outside air temperature drops below 36 degrees as part of a seasonal weather change lasting for an ex tended period of time Marcite A white plaster type pool wall and surface finishing ma terial made of white Portland cement and marble dust Migrate Referring to concentrated chlorine moving through the filter system plumbing with or without the water flowing Motorized Plumbing Valves Valves that are driven by low volt age motors mounted on top of such a valve Usually used to change from pool to spa mode via a control switch or device without hav ing to go to the filter system and turn these valves manually Muriatic Acid A liquid acid that is used to lower the Ph of pool water Handle with extreme caution Use a dry powder acid for spas Normal Operation When the heat pump is running as intended by the manufacturer Nozzle Attachment A device attached to the end of a garden hose that increases pressure and control
11. or worn filters or clogged lint traps Clogged filter pump impeller Improper plumb ing valve settings Suction leak allowing air into the water flow It is cold outside Pool pump timer is not set for a long enough running pe riod Pool is not covered High wind speed over pool Shaded pool area The optional motorized plumbing valves are out of synchronization with the dual thermostat con trol The motor valves are not turning The manual pool spa valves have not been turned correctly A third party external control device is overriding the dual control Motor valves have a tendency to rotate after a power outage and then they are out of sync Low or restricted water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumb ing valve settings Suction leak allowing air into the water flow Low water flow when switched to spa mode Compressor was not preheated properly reciprocating type R series only Scroll type S series compressors only require several start cycles before it will start when new during cold temperatures or if the unit has been idle for some time Weak power supply voltage The heater produces water condensation when itoperates The water will trickle from the drain holes designed in the bottom of the heater The higher the humidity the more water condensa tion the heater will produce This is similar to the effect that a glass of ice water has when it swea
12. that you desire nir oan inn ae LIII ae e z Ner or 1 5 F Max E a e Thermometer If the pool temperature on the thermometer reads 80 degrees F and you turn the thermostat to the left until the heater shuts off the thermostat will now be set at 80 degrees F Now the heater will come on each day when the circulation pump starts then it will bring the pool up to that set temperature The pool will lose some heat overnight but will come back up to temperature with minimal delay If you have a pool and spa combination you can set the spa thermostat the same way once you are in the spa heating mode When adjusting the thermostat remember that it will take some time for the water temperature to reach a higher setting The cooler the outside air the longer heat up time needed CAUTION AKE SURE YOU ADJUST THE THERMOSTAT BACK FROM THE HIGHEST POSITION SET DURIN HE START UP PROCEDURE OR THE POOL MAY GET TOO WARM BE SURE TO RESET THE CIRCU ATION PUMP TIMER FOR 6 TO 18 HOURS PER DAY OR AS NEEDED ACCORDING TO THE SIZE OH OUR POOL AND WEATHER CONDITIONS COLDER CLIMATES WILL REQUIRE MORE TIME ARGER POOLS WILL REQUIRE MORE TIME EXPOSED POOLS WILL REQUIRE MORE TIME WIN ER TIME OPERATION WILL REQUIRE MORE OPERATIONAL TIME EACH DAY UNDERSTANDING HEAT LOSS It is important to understand how your pool loses heat The greatest heat loss occurs at the water surface You will need to adjust the operational time t
13. you have selected the spa mode with the pool spa select switch dual thermostat control only This light will be inactive when used with the standard single thermostat control pool only WATER PRESS OK Green The green water pressure OK indicator light tells you that the internal water pressure switch is OK The internal water pressure switch is used to shut the heater on and off with the circulation pump The heater should not run when the water pump is not pumping water through the heater Dirty filters and lint traps will cause low water flow to the heater and may cause the water pressure switch to deactivate the heater If this light stays off clean all filters and check all filter system valving to insure proper water flow See pages 12 13 and 20 for more information regarding water flow requirements When this water flow indicator light is off the t stat light and the low and high press lights will not come on either and the heater will stay off T STAT ON Green The green thermostat on indicator light is used to let you know that the thermostat is set higher than the pool or spa water temperature If the light is not on turn the thermostat to a higher position and the fan should then start compressor starts after a 5 minute delay If the thermostat is already all the way up and the light is still off means that the pool or spa water temperature has reached the maximum of 104 F or allowed When this light goes off the heater has h
14. ALINITY Total Alkalinity is a test given to determine the over all mineral content of the water Total alkalinity lev els should be within the range from 90 p p m to 120 p p m The total alkalinity is described as a buffer against acetic conditions and acts as a stabilizer for the pH It keeps the pH from fluctuating up and down A low alkalinity will allow the pH to fluctuate usually to the acetic side A high alkalinity may cloud the wa ter The pH of your water will change when it is used after rain from dirt and debris and many other natural conditions The proper total alkalinity will prevent those changes from being drastic Test for total alka linity on a weekly basis CALCIUM HARDNESS Calcium Hardness levels should remain within the range from 250 p p m to 400 p p m Calcium hardness is a test that determines the saturation levels of calcium and magnesium salts in the water This tells you in lay man terms how hard the water is Please refer to your pool builders instructions concerning calcium hardness and how it effects your particular pool surfacing mate rial POOL CHEMICAL amp CHLORINATOR USE When you are adding pool chemicals as part of your regular maintenance there are several rules of thumb to follow Where you add the chemicals are just as important as how much you add This section will discuss the do s and don ts of where you add chemicals or where chlorinators are placed PROTECT HEAT EXCHANGER Yo
15. Call your installer for advice Call the factory for advice Clean entire filtering system and or replace fil ter element Inspect amp clean pump impeller Adjust all plumbing valves Repair suction air leaks grease pump lid o ring Replace filter Preheat reciprocating type R series compres sor for 8 hours Allow Scroll type S series compressors several start cycles Have a li censed electrician check the power supply volt age and wire size Call your installer for ad vice Call the factory for advice Shut the heater off for several hours but leave the pool water pump running Allow enough time for all the normal condensation to evapo rate If the heater continues to trickle water af ter that time when it is not running you may have a pool water leak You can test this water for chlorine to confirm Make sure your chlo rinator has a check valve and loop installed be tween the heater amp chlorinator ELECTRICAL WIRING SPECIFICATIONS N WARNING The heater must be electrically grounded and bonded in accordance with local codes or in the absence of local codes with the latest national electrical codes ANSI NFPA No 70 All wiring must comply with all local codes or in the absence of local codes with the latest national electri cal codes ANSI NFPA No 70 For proper wire and or breaker size please refer to specification sheet and your local licensed electrician Unit has 3 4 knockout on left side of unit
16. GS FOR HEAT amp COOL MODELS For heating mode on these models make sure toggle is selected to heat and follow the pre vious instructions above For cooling mode make sure toggle is selected to cool Turning down the thermostat counter clockwise will start the unit running When the pool water has been cooled to the thermostat setting the unit will shut off When the pool water temperature rises one to two de grees the thermostat will activate the unit There are no temperature graduate numbers printed on the thermostat face To obtain an exact temperature turn the t stat all the way down and then place a pool type thermometer in the pool water itself Once the water has reached your target temperature on the thermometer turn the thermostat knob forwards until the heater just shuts off Therefore your Water Pressure Switch Location thermostat will be set at the thermometer reading FAN AIR CIRCULATION Once the t stat is activated the fan will begin to turn To collect the heat from the air the fan circulates warmer air through the evaporator air coil at about 4200 cubic feet per minute The fan runs independently from the compressor The compressor will start within 5 to 7 minutes after the fan EVAPORATOR AIR COIL The fan circulates the warmer outside air through the evaporator air coil to collect any available heat The cooler refrigerant ab sorbs this heat This evaporates the refriger ant into a gas The
17. OPTIONS ACCESSORY MANUAL TECHNICIANS ONLY OWNERS MANUALS Manufactured By Pentair Pool Products Inc 2 WARNING THE MISUSE OF THIS PRODUCT CAN RESULT IN SEVERE INJURY DEATH OR PROPERTY DAMAGE BE ADVISED OF THE FOLLOWING CONDI TIONS THAT MAY EXIST ELECTROCUTION AND OR FIRE DUE TO IMPROPER WIRING HAND AND HAIR ENTRAPMENT MAY OCCUR NEAR THE FAN LO CATED ON THE TOP OF THIS UNIT LOSS OF POOL WATER AND OR FLOODING AND OR PROPERTY DAM AGE DAMAGE AND OR MISUSE TO THE PRODUCT RESULTING IN FAILURE OR EXCESSIVE WEAR ALL ELECTRICAL WORK BY LICENSED PROFESSIONAL ONLY Owners users should contact the factory service department for advice at Pentair Pool Products Inc 800 831 7133 HEAT PUMP EFFICIENCY Your new highly efficient heat pump pool spa heater will deliver warm pool water for your comfort for pen nies a day For every dollar you spend to run your heat pump you will receive between 4 00 and 5 00 worth of heat in return The heat pump transfers the heat from the outside air to your pool or spa Your heat pump costs about 60 to 75 percent less than L P Gas heaters to operate with less maintenance and gas storage tank is not needed Your heat pump produces no pollution and no pilot lights to deal with Approximate Cost Per 100 000 Btu s of Heat 1 65 2 34 1 10 mum 0 96 zm 0 32 LP Gas Natural Heat Gas Pump Electric Oil RETURN ON INVESTMENT The costs of ins
18. Shown here with a roller attachment Using a pool cover can be somewhat cumbersome but they are worth the trouble in regards to the great cost savings Covers are sometimes referred to as blankets or solar blankets WARNING NEVER SWIM WITH POOL COVER ON Swim mers can tangle easily in the pool cover and subse quently may result in drowning See manufacturer s Safety Precautions before using SPAS HEATING TIPS It is strongly suggested that you use a cover during the initial heat up time This will save time as well as elec trical costs When heating a spa make sure that there are no air bubbles coming from the air blower or hydrotherapy air inlets The air bubbles will dissipate the heat into the air and prolong the heating time Electric air blowers inject cooler outside air into the spa and will lower the temperature You can shorten the heating time of your spa by shutting off any air injec tion devices until the spa is up to the desired tempera ture If you have any health problems high blood pressure etc consult a doctor before using a hot water spa You should get out of the spa and cool off every fifteen min utes Do not consume alcoholic beverages while using the spa To prevent drowning do not use the cover while in the spa OWNERS MAINTENANCE amp CARE There are some considerations that should be taken concerning the environment where your heater is installed The heater is usually placed near the poo
19. Typical Circulation Pump VACUUM amp PRESSURE LEAKS All vacuum and pressure leaks in the filtering system must be eliminated immediately after occurring Air allowed into the filter system from the vacuum side of the circulation pump will cause premature wear and physical erosion to the heat exchanger and water pip ing inside the heater Air turbulence will cause the wa ter pressure switch to malfunction Pressure leaks on the filtering system will allow the sys tem to lose vacuum and cause the water in the filter and piping to back siphon or reverse flow through the sys tem when the circulation pump is off Reverse flow may cause the water pressure switch to malfunction CHLORINATORS See chlorinator placement and chemical use guide lines 16 FILTER CLEANING amp CARE Your filter system should be cleaned at least twice a month See manufacturer s directions for proper filter cleaning methods Size and conditions may require you to clean the filter more often A filter is considered dirty whenever it restricts the flow rate by 10 or more You can use the pressure gauge on the filter tank to de termine a restriction in the filter due to clogging After the filter has been replaced or when it is new you should record the actual operating pressure with a clean fil ter When the pressure increases more than 5 p s i the filter should be cleaned If the pressure does not return to normal you must replace it Make
20. a compressor start time delay and generally it will not start for about 5 to 7 minutes Cooler air will come from the fan when the compressor is running Become familiar with the compressor sound and remem ber the compressor time delay Scroll compressors may not start on the first try Allow Scroll type compressors several starts and time delay cycles before the compressor starts This condition is most common to new compressors or when starting 10 during colder air temperatures THERMOSTAT SETTING There are no temperature reading numbers printed on the thermostat dial due to calibration changes from unit to unit The demand for exact temperatures should be regulated by using a high quality thermometer right in the pool water Normal temperatures for pools are 78 to 82 degrees F Spa temperatures are 98 to a maximum of 104 degrees F You should place a high quality tie on type or a floating type thermom eter directly in the pool or spa water so you can determine what tempera ture that is suitable to you Check the pool temperature occasionally during the heat up time until it has reached the temperature you desire Then go to the heater and turn thermostat counter clockwise to the left away from warmer SLOWLY until the unit just shuts off Therefore the thermostat will be set exactly at the current temperature shown on your floating thermometer Make a mark on the thermostat dial so you know the QA A A 2 approximate setting
21. ain as possible Install two shut off valves on the water in and out lines as shown here The rest of the water should be blown out with pressurized air to insure all water is removed A antifreeze designed for water with pressurized air Stagnant water left in the heat exchanger can cause corrosion and will freeze causing damage 25 OWNER TROUBLE SHOOTING GUIDE WARNING Risk of electrical shock or electrocution Improper installation will create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property Do NOT attempt any internal adjustments inside the heater 1 Keep your hands and hair clear of the fan blades to avoid injury 2 If you are not familiar with your pool filtering system and heater a Do not attempt to adjust or service without consulting your dealer professional pool or air conditioning contractor b Read the entire Owner and Installation Manual before attempting to use service or adjust the heater or pool filtering system CONDITION POSSIBLE CAUSE POSSIBLE REMEDY All control lights off No power supply to heater Tripped breaker or Reset breaker Replace fuse Call dealer for Unit will not start blown fuse Control failure advise Call factory for advise Low water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumbing valve settings Suc
22. anger Hot The seamless tube within another tube design trans Refrigerant fers heat very efficiently The inner water tube is made dx ap of thicker resilient cupronickel metal alloy to help re r 9e NC rr sist corrosive pool water The outer heavy gauge Freon tube is dipped in a special weather proofing E material Then to insulate from heat loss and help pre T vent exterior corrosion the heat exchanger is encased i bic Water Passage m in a block of special closed cell foam Cupronickel Metal Alloy 20 These chemical outlines should not be considered as a how to balance your pool spa water but just a refer ence on how chemical balance effects the heater and gives suggested test values You should always consult a pool professional and follow all chemical manufacturers di rections unless they conflict with this manual CHLORINE Chlorine levels should remain within a range from 1 p p m to a maximum of 5 p p m p p m parts per mil lion Excessive chlorine saturation of the pool water will cause corrosive damage to the heat exchanger Chlorines Effect on pH Review the diagram on the previous page Some tablets granular and gas forms of chlorine have an acetic nature to start with and may lower the pH of the water when introduced see diagram on previous page Be sure that the pH remains between 7 4 and 7 8 after adding chlo rine If these types of chlorine are introduced into the s
23. ant pres sure caused by a Freon leak Possible mal functioning of the internal low refrigerant pres sure switch Low or restricted water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumb ing valve settings Suction leak allowing air into the water flow Low water flow when switched to spa mode Unit is plumbed backwards Heat exchanger clogged with debris Internal bypass valve damaged or clogged with debris Water temperature exceeding 104 F maximum Re frigerant system malfunction Low or restricted water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumb ing valve settings Suction leak allowing air into the water flow Low water flow when switched to spa mode Unit is plumbed back wards Heat exchanger clogged with debris Internal bypass valve damaged or clogged with debris 26 Clean entire filtering system and or replace filter element Inspect amp clean pump impel ler Adjust plumbing valves Repair suc tion air leaks grease pump lid o ring Re place filter Replace water pressure switch Turn the thermostat up to the right more Use a high quality thermometer to test the water temperature Maximum water tempera ture is 104 F or 3 F Call your dealer for advise Call the factory for advise Do not try to operate the heater when the outside air temperature drops below 36 F and 45
24. ary with pool size exposure and weather conditions ADJUSTING THE TIMER Timer styles vary read the manufacturers instructions before attempting to reset timer Make sure the plastic guard is in place On this type of timer note the On and OFF trippers located on the clock face If you loosen the lock screw on the tripper you can move it to anew time Make sure the time of day is correct To run the 24 hours needed for the initial heat up just remove the OFF tripper When the pool reaches tem perature replace the tripper and set timer to run the water pump during the hottest part of the day Read your particular timer manufacturers instructions to identify the one you have Do not attempt to adjust the timer unless you have read these instructions COMMON MECHANICAL TIMER 24 Hour Clock Face ON Tripper Peg OFF Tripper Peg Tuleator pala NORMAL RUNNING TIME The heat pump system extracts the heat from the out side air and delivers it to your pool Therefore it pro duces more BTU s heat the warmer it is outside So take advantage of the higher air temperatures during the day by setting the timer for the warmest hours Win ter operation during cold fronts may require longer run times up to 16 hours daily SET THERMOSTAT TO MAXIMUM Turn the thermostat dial all the way to the right You will turn the thermostat back to a lower position later as described on the next page The fan should now be turning There is
25. at work better for spas and are somewhat milder and are easier to handle 6 All the same rules of chemical application and chlorinator placement that apply in the previous chemical section also apply to spas Always consult a professional pool builder or service and follow the chemical manufacturers directions 24 SHUT DOWN amp FREEZE PROTECTION PROCEDURES When shutting the unit down for the end of the swimming season you must consider some items to protect the unit from inclement weather It is best in most situations to shut the unit off by turning the thermostat all the way down to the left Leave power circuit breaker to the unit on unless the pool or spa water temperature drops below 50 degrees F SHORT TERM FREEZE PROTECTION PROCEDURES When the outside air temperature is forecast to drop below 32 degrees F for a short time You should set the circulation pump timer to run 24 hours per day in order to circulate water through the unit and filtration system Standing water inside the piping will freeze and damage the water heat exchanger and refriger ant system Shut the heat pump off and do not try to heat the pool during freezing temperatures If the unit is left running it may ice up and the compressor will stop running The defrost control inside the unit will shut the compressor off but allow the fan to run The fan will circulate air through the unit to help defrost the evaporator air coil If you know that the temperatu
26. by the vacuum created by the water in the filtering being above the pool level or breach in the sealed water plumbing allowing air into the system This condition is sometimes referred to as a suction or vacuum leak Back Pressure The pressure created by the circulation pump be ing restricted by plumbing filters solar panels and other related equipment Usually due to a dirty filter measured by the pressure gauge in the filter housing Blanket A plastic cover several mills thick with trapped air bubbles cut to the same size as the pool and floats on top of the water to provide insulation and prevent heat loss Some types collect small amounts of heat from the sun and transfer it to the pool water Sometimes referred to as a solar blanket BTU British Thermal Units Measures heat output of a heat pump in Btu s per hour 30 Broadcast Type Sprinklers Part of an irrigation system used to water plants or grass where the water is sprayed into the air and distributed directional Bypass Used in the water piping to allow the control of water flow through the heater at a prescribed rate thus the rest of the water flow not needed is diverted through the bypass Calcium Hardness The amount of calcium and magnesium con tent in pool spa water calculated by using a test kit for such pur poses Calcium Hypochlorite A form of chlorine in a powder form and rarely ina tablet form used to sanitize pool spa water Calcium is a major co
27. ced through the fins to produce the reac tion due to dissimilar temperatures Expansion Valve A control valve that regulates the Freon pressure to the evaporator coil Fan Used to move air through the evaporator coil Fan Blades The aluminum mechanism that moves the air through the unit Located on top of the cabinet Caution fan blades can be sharp and cause injury Filter Use to clean the pool water by pumping water through a media that collects debris and is cleaned later as part of regular pool maintenance Filter System The equipment installed to circulate and clean the pool water usually consisting of an electric water pump on a timer a filter containment flow control valves and other equipment needed for that particular pool and or spa Floating Chlorinator A device that floats on the pool waters sur face that feeds chlorine to the water by eroding solid tablet type chlorine inside its containment Floating Thermometer A thermometer that floats on the water surface with the main sensing bulb in the water Indicates the ac tual pool or spa temperature it s floating in A tie on type will work the same Flow Control Valve A valve or check valve that controls water flow either automatically or manually Freon Trade name for a type of refrigerant The heat transfer medium used to transfer the generated heat to the pool water in the vapor compression cycle of the heat pump system Changing from a gas to a li
28. d Thermostat Setting e Heat Loss amp Pool Covers 3 OWNERS CARE Dd sinsi 14 17 a Placement Area b Sprinkler Placement amp Plants amp Condensation Run Off c Clearance and Air Flow d Cleaning The Unit e Pool Circulation System Maintenance f Auto Vacuum s amp Vacuuming 4 PLUMBING amp WATER FLOW sssssssnsrssssssasssctoconseassnnsosssensessavecesscassvessessscessnseonsesssasvasscsssusssoasoeonse 18 19 a Plumbing Connections amp Auto Bypass b Large Water Pump Plumbing Bypass c Mandatory Chlorinator Loop amp Check Valve 5 CHEMICAL amp CHLORINATOR APPLICATION amp USE e recess eee eren eene ene enne tne 20 24 a Water Quality and Testing Values a Heat Exchanger Protection amp Sacrificial Water Fittings b Chemical Feeder Placement amp Use amp Hand Feeding Chemicals c Commercial Feeders d Spa Chemical Application 6 SHUT DOWN AND FREEZE PROTECTION PROCEDURES ee eeeeee ee eene een etn sna 25 a Seasonal Shut Down b Short Term and Long Term Freezing Protection 7 OWNERS TROUBLE SHOOTING GUIDE s eenass asse ao ooa saos aot ones thence toss ons va snas ta simae 26 27 8 ELECTRICAL WIRING SPECIFICATIONS BY MODEL NUMBER eerte 28 8 HOW TO GET SERVICE e m 29 10 GLOSSARY OF TERMS 30 33 ADDITIONAL MANUALS AVAILABLE INSTALLATION MANUAL TECHNICIAN ONLY
29. drain from the bottom of the unit Do not mistake condensation with a water piping leak There is a certain procedure to follow to check the unit forleaks Shut the heat pump and filtering system off Allow all the condensation to drain from the unit for at least an hour or so Then start the circulation pump only leave the heater off If the unit is still leaking water steadily you may have a water piping leak The unit should not condensate when the heater is off Consult your dealer 15 FILTER SYSTEM MAINTENANCE REQUIREMENTS WATER FLOW Proper water flow is critical to the heaters performance and longevity The maintenance of your filtering sys tem is directly related to the proper operation of the heat pump See pages 8 for other information regarding filter cleaning and the start up procedures CIRCULATION PUMP The circulation pump must be kept in good working order to provide a steady rate of flow to the heater and filtering system as a whole The circulation pump must be producing a flow rate in accordance with the manu facturers specifications within 10 The pump should run with a full prime without excessive restriction on the vacuum and pressure side of the filtering system Discharge Outlet Pressure Pump Lid Suction Inlet di eS D i e Lint Trap Impeller Housing
30. e the heat ex changer and piping Chemical Loop Filter 8 Above AI Heater Chlorinator d Lo S55 Pump a I Lf 2lb Chemical Resistant Check Valve In Line Type Chlorinator See plumbing amp water flow and high rate water pumps for more information COMMERCIAL FEEDERS We strongly suggest that all chemical feeders be placed down line of the heater In a closely monitored commercial pool situation where a vacuum type filter system is used in conjunction with a surge tank there are some exceptions to chemical injection Some liquid chlorine sodium hypochlorite feeders and liquid muriatic acid feeders will inject their solutions into the surge tank on the suction side of the unit You may inject diluted liquid chlorine and muriatic acid as long as each are diluted with 75 water in the supply tank The feeders must be adjusted to a slow enough rate to prevent the water in the surge tank from dropping below 7 6 pH and or chlorine levels above 5 p p m You can test the surge tank water while the feeders and circulation pump is running just as you would the pool water Then adjust the solution or rate of feed accordingly The circulation pump usually moves the water through the surge tank rapidly enough to keep chemical concentrations down Never place chlorine tablets in the surge tank Also note Electric type feeders must be electrically relayed to the circulation pump so the feeders will shut off wh
31. eated the pool or spa to the preset temperature When this light is off the heater and the low and high pressure lights will stay off LOW PRESS OK Green The green low pressure indicator light is designed to let you know that the low side refrigerant pressure is OK If the refrigerant pressure was too low for the unit to operate this light the heater will shut off The heater is charged with Freon refrigerant If the outside air temperature drops below 40 degrees the refrigerant pressure will drop below the required operational range The internal low refrigerant pressure switch will act as a defrost control to keep the unit from forming ice on the outer evaporator coil when this light is off It may also indicate that the unit may have a refrigerant leak as well When this light is off the high pressure light and the heater will be off as well HIGH PRESS OK Green The green high pressure OK indicator light is used to tell you that the heater is operating at the correct high side refrigerant pressure range If the refrigerant pressure exceeds the maximum needed for proper operation this light and the heater will shut off Excessive high refrigerant pressure is usually caused by low water flow through the heater If this light goes out clean the filtering system and check all plumbing valves to insure proper water flow then try to restart the heater See pages 8 18 and 19 for information regarding water flow When this light is off the heater w
32. eater off hen the vacuum hose is plugged in it may cause the pump to loose prime due to the air in the hose Yo ay also need to restrict the main drain suction port to bain more vacuum to the vacuum hose and head This ill lower the overall flow through the unit and cause it o cycle on amp off possibly causing damage Shut the eater off whenever there is a chance of restricted wa er flow or loss of prime PROFESSIONAL SERVICE As part of routine maintenance you should schedule a licensed air conditioning contractor or the factory ser vice department to check the refrigeration circuit and components of the heat pump against factory specifica tions An improper adjustment or diagnosis by others may limit your warranty You can call the factory ser vice department for a list of factory authorized service centers in your area Have all the refrigeration compo nents checked against the factory specifications You can request this information from the factory service department Verify correct installation according to the owners and installation manuals Verify water flow through the heat exchanger and filtering system Check all chlorinator placement and pool water balance Test the supply volt age amperage draw wire size against factory specifi cations and local codes Test the operating refrigerant pressures and corresponding components to factory specifications Adjust refrigerant according to the sub cooling reading and
33. en the pump does CHEMICAL APPLICATION FOR SPAS Spas require some special attention due to their small water volume and high heat compared to a normal swim ming pool A spas water balance fluctuates more rapidly than a pool The following are suggestions that we feel will prolong the life of the heat exchanger used for a spa heater 1 Test the water frequently to prevent drastic fluctuations in pH and sanitizer levels especially after usage Keep total alkalinity at 100 p p m to 120 p p m 2 Spas react quickly to chemicals when added Use small amounts and retest the water until you reach the desired chemical values 3 Some chlorine tablets are very acetic and will lower the pH of the spa water as the solution is fed Make sure the spa water does not drop below 7 4 pH see page 20 and 21 for more information 4 Bromine has a more neutral pH value and works well in spa water if pH is maintained at 7 8 8 0 It is a form of chlorine widely used for spas Do not install a brominator on the suction side of the filtering system WARNING Working with muriatic acid can be dangerous When cleaning elements always wear rubber gloves and eye protection Add acid to water do not add water to acid Splashing or spilling acid can cause severe personal injury and or property damage 5 Using muriatic acid right from the bottle at the same strength as packaged may drastically lower the pH uncontrollably There are some dry powdered forms of acid th
34. ency Higher than 7 6 indicates that the water has alkaline tendency pH Below 7 4 Will A lower acetic pH reading will cause corrosion to the heat exchanger Prolonged exposure to low pH and or high chlorine will damage the heat exchanger The lower the pH the more aggressive the chlorine is and the quicker the damage takes place The metal is oxi dized and deteriorates Piping Leaks amp Stains An early indicator of low pH and or high chlorine would be if a leak were discovered in the piping lead ing to the heat exchanger The copper in the piping will dissolve into a solution and mix with the pool water This dissolved metal will show back up as a blue green colored stain on the masonry materials in your pool The commonly used white plaster Marcite finishes will stain from the metal in the water quite easily Although there will have already been some chemical damage You can make corrections immediately to pro tect the very expensive cupronickel heat exchanger Follow the chemical guidelines in order to prevent such damage from occurring Do not wait until you see the metal stains or piping leaks pH Above 7 8 Will If your pool water is extremely high in pH alkaline you may get a mineral build up in the heat exchanger and piping Restriction from build up will restrict the water flow to the heater This condition is very rare except where mineral content is high in the tap water used for the pool TOTAL ALK
35. er water Coil Cupronickel Alloy amp Insulation 1 PYC Foam Block Flex Fi pe Compression Fittings m 2URI XZU PYC T DEW riable Rate Spring Bulkhead IN bm 2 PYC Pipe I N Front Cabinet E y Excessive Flow Valve Manifold Do not valve in a manner that will totally isolate heater from water flow see page 25 CAUTION BE SURE THE BYPASS VALVE IS POSITIONED TO ALLOW REMOVAL OF THE FRONT ACCESS PANEL Position the valve so that the access panel can be easily removed always check before final glu ing Angle the valve out 45 to provide adequate clearance You may use a 2 way valve or other type if desired Do not use a brass gate valve or a 3 way valve for bypass LOOP ABOVE i 2 LB 8 CHEMICAL RESISTANT CHECK VALVE Part 888 018 WATER BALANCE MAINTENANCE The chemical balance of your pool spa water and the methods used in adding pool chemicals will directly effect the life of your heater Like no other precaution you could take it is very important that these guidelines are followed in order to prevent damage to the heat exchanger water coil and possibly the entire system Improperly maintained water balance and incorrect introduction of pool chemicals will cause extreme corrosion to the heat exchanger If this condition goes unnoticed it will eventually damage the compressor and evaporator coil The heat exchanger in your unit is made of the highest quality cupr
36. ers are clean and the pump is run ning with a full prime you will need to set the pool circulation pump timer Set the filter pump time clock for a long enough period of time to heat the pool or spa The heater will not operate unless there is water run ning through the heat exchanger supplied by the circu lation pump Therefore your pool will only heat dur ing the period set on the timer When setting the timer be sure that you shut off the pool circulation pump cir cuit breaker Then follow the timer manufacturers in structions to prevent electrical shock Consult your dealer first INITIAL HEAT UP TIME HEATERS You should start by letting the circulation pump run 24 hours a day until the pool reaches the desired tempera ture Once the pool is up to your desired temperature you should reset the timer for a cycle of 6 to 18 hours per day during the hottest part of the day Heat up time and operational time will vary with pool size exposure and weather conditions Spas will require considerably less time to reach temperature usually in a matter of hours if a cover is used INITIAL COOL DOWN TIME HEAT amp COOL MODELS You should start by letting the circulation pump run 24 hours a day until the pool reaches the desired tempera ture Once the pool is down to your desired tempera ture you should reset the timer for a cycle of 6 to 18 hours per day during the coldest part of the day Cool down time and operational time will v
37. he manufacturers directions for proper filter cleaning methods You must eliminate any water flow or filtering system problems Check all electrical service breakers and switches 2 Inform your dealer that the unit is having trouble and you would like them to check the unit for any obvious non watranty problems including but not limited to installation specifications water flow and filtration problems bypass adjustment timers and control devices or any field installed options that may effect normal operation of the heat pump 3 Make sure the filtering system and any control devices are properly adjusted and corrected before you request service from the factory These listed items and others like them are not considered factory defects If the factory authorized warranty service is sent to the site and no factory defects are found or there is a problem not associated with the unit as it was manufactured the pool owner will be liable for all charges Water flow adjustments filter cleaning and control devices etc that effect the heater or damage caused by such equipment is not covered under the warranty agreement The pool owner is responsible for the correct adjustment and maintenance of the filtering system 4 If the dealer is unavailable to help you the factory service manager will assist you or your pool service over the phone The service manager will give suggestions on how to check the filtering system and other obvious prob lems You
38. hts Cloud cover will reduce this type of heat loss RERADIATION CONVECTION EVAPORATION Pool Surface CONDUCTION Warm Pool Water _ Pool Shell 12 CONTROLLING HEAT LOSS A good way to control heat loss is to slow the wind speed through your pool area by placing plants such as shrubs or bushes around the pool s perimeter Plants will break up the air flow and diffuse the wind speed If the pool area is to be fenced in choose a wood shadow box type design WIND Lll Wind Break Shadow Box Fence Plants A solid type fence or wall does not act as a good wind break They tend to create a wind spoil vortex across the water surface increasing air turbulence and heat loss Pools located in windy areas such as water front golf courses or open fields will experience greater heat loss wind Current Wind Spoil Meer rc eS wall P4 COVERS SAVE TIME amp MONEY As discussed on the previous page the greatest heat loss is at the water surface The very best way to reduce heat loss and operational cost is to cover the pool or spa Covering the pool or spa during the initial heat up time will help the pool get to the desired temperature much faster If properly used a cover can lower your total operating costs as much as 5096 Covers reduce evapo ration thus you will save on pool chemicals and fill water usage as well 13 TYPICAL POOL BLANKET amp ROLLER Pod Pool Blanket Cover
39. ill not run 7 START UP PROCEDURES TURN T STAT ALL THE WAY DOWN Make sure the thermostat dial is turned all the way to the LEFT so the unit will not start until you are ready Then turn the circuit breaker on COMPRESSOR TIME DELAY BE AWARE THERE IS A5 TO 7 MINUTE TIME DE LAY BEFORE THE COMPRESSOR WILL START ONCE THE UNIT IS TURNED ON OR WHENEVER IT RESTARTS All models ADVISE YOUR POOL SERVICE CO If you have a regular pool service on a weekly basis make sure your owners manual available for them to inspect You may request that one be sent to them by calling the factory service department at 800 831 7133 Be sure that they are aware of the chemical balance and chemical introduction rules in this manual The condi tions in this manual must be followed in accordance with the warranty if for any reason the heater is improperly installed and or operated the manufacturers warranty may be void CLEAN FILTERING SYSTEM Next make sure that the pool filter is as clean as pos sible A dirty filter will hamper the efficiency of the unit and cause the unit to cycle on and off resulting in damaging effects Filters may look clean but can be clogged with oils or minerals Replacement is suggested every year and a half for cartridge type filters See manu facturers directions for proper filter cleaning methods Next clean the lint trap basket inside the circulation pump Then clean the skimmer leaf trap basket of all debr
40. is A clogged lint trap or skimmer basket will restrict the water flow to the unit Make sure there is adequate water in the pool so that the skimmer does not draw air Never place any chemicals of any type espe cially chlorine in the skimmer If you are unfamiliar with your pool filtering system you should consult your local pool company The dia gram shown above are not of any specific brand but are common in nature The following diagram is of a typi cal filtering system WATER FLOW amp EXISTING WATER PUMP To filter the pool water each day the water pump will come on amp off according to the existing timer device The heater will only heat if there is water running through it WATER PRESSURE SWITCH If there is proper water flow through the unit the water pressure switch will close allowing the unit to run When the circulation pump timer stops the water flow the water pressure switch will shut the unit down When the pump restarts for the next day the pressure switch will close and allow the heater to run Water Pressure Switch Location Filter amp Trap Locations Pressure Gauge Leaf Trap Basket O Ring Filter Cartridge or Filter Element Skimmer Pump Lid O Ring Cc ir sh T i i EN Lint Trap ii 1 EB i H Return Circulation Pump From Heater Chiorinat Ehlarinatar Loop ara a
41. l Cleaner Often times when these auto vacuums begin to wear they require more suction from the pump to operate Diverting all vacuum through the auto vac may help it run better but will restrict the overall water flow through the entire system and the heater If you have a low water flow situation where the heater is not getting enough water through the condenser coil remove the pool vac and open all skimmer and main floor drain vacuum valves to provide maximum flow The auto vac manufacturer has a special valve that plugs into the skimmer before the auto vac hose These spe cial valves will properly regulate the water flow through the auto vac without creating too much vacuum restric tion on the skimmer suction port The hose connecting the auto vac to the skimmer should be checked for the presence of suction leaks that allow air into the system See damage caused by vacuum leaks previously As the auto vac hose gets older and sun damaged it may develop an air vacuum leak or known as a suction leak In all cases you should do what ever necessary to gain the proper water flow through the heat exchanger Once the pool vac is working make sure you have the proper water flow through the heater at all times If the low flow created by an auto vac is causing a problem with the unit it is not considered a warranty condition NCAUTION hen manually vacuuming the pool or performing ser ice to the filtering system shut the h
42. l filtering system There are certain things in this area you will need to be aware of to insure long life and prevent unnecessary damage SPRINKLERS Make sure there are absolutely no sprinkler heads near the heater that will in any way spray on or into the heater Sprinkler damage is not covered under the warranty agreement Make sure that they are a sufficient distance away so that normal winds will not carry the mist to the heater If your filtering system area has plants that need water use a trickle type irrigation sprinkler instead of the broadcast type HO SPRINKLERS The heater is designed to handle the wettest weather conditions that are typical of rain and humidity etc Sprinkler heads force high pressure water into the unit from the side at an odd angle Most sprinkler sys tems are connected to a well system Most well water is high in miner als sulphur and other aggressive contaminates These contaminates will leave a build up on the evaporator coils and electronics causing corrosion and hamper the efficiency If you are located within 15 miles of the coast salt may be in the well water also WITHIN A 6FT RANGE PLANTS Plants in the installation area should be kept trimmed away to the proper clearances shown here Plants too close to the heater will restrict the air flow into the unit from the side as well as air flow through the top Plants also bring extra moisture and insects that may get inside the u
43. may save yourself the cost of a service call and learn more about your pool heat pump if you take the time to seek advise before requesting the factory service crew Literature can be sent to you directly that will help you understand the heat pump system 5 Once you have made contact with the dealer or the factory service department make sure that you can be present when the heater is serviced The authorized factory service centers will require the pool owner or dealer be present Required Information Heat Pump Service Department 800 831 7133 seriat 0 0 0 0 Model at Install Date Dealer Name _ The actual receipt or canceled check may be needed to verify installation date and proof of ownership Any service request resulting in a repair or adjustment not considered a factory defect with the heater as it was manufactured will be the responsibility of the heater owner and therefore billed directly to the owner Always read and follow the owners manual and then seek advice from your dealer and or the installer BE ADVISED THERE ARE SEPARATE INSTALLATION SERVICE amp ACCESSORY MANUALS 29 GLOSSARY OF TERMS A C Contractor A company licensed by the state and local au thorities to perform heating ventilation and air conditioning in stallation or repair including pool heat pumps Allow no others to repair this unit Acetic Describing pool spa water that is aggressive in nature with a Ph value below 7 6 Like acid ora
44. mp Check Valve OPERATIONAL SEQUENCE WATER FLOW amp EXISTING WATER PUMP To filter the pool water each day the water pump will come on amp off according to the existing timer device The heater will only heat if there is water running through it and it op erates long enough pool om f or a IN OUT spa Boing E m WATER PRESSURE SWITCH When water starts flowing through the unit the water pressure switch will activate and allow the unit to run When the circulation pump timer stops the water flow the wa ter pressure switch will shut the unit off When the pump restarts for the next day the pressure switch will activate and allow the heater to run again THERMOSTAT CONTROL amp SETTINGS Turning up the thermostat will start the unit When the pool water has been heated to the thermostat setting the unit will shut off When the pool water temperature loses one to two degrees the thermostat will activate the unit There are no temperature graduate numbers printed on the thermostat face To obtain an exact temperature for a pool turn the t stat 3 4 s of the way up and then place a pool type thermometer in the pool water itself Once the water has reached your target temperature on the thermometer turn the thermostat knob backwards until the heater just shuts off There fore your thermostat will be set at the thermom eter reading THERMOSTAT CONTROL amp SETTIN
45. mponent and by product Cartridge Filter A pool spa water filter that is made of pleated paper and nylon Usually round with plastic base and top placed into a tank that the water is pumped through trapping debris and dirt Usually removed and cleaned with a high pressure garden hose Check Valve A P V C fitting used on the water piping to prevent reverse flow through the system and insure proper water direction Sometimes used to create back pressure and slow the water veloc ity Chemical Values The numerical reading you get by using a pool spa water test kit to calculate levels of pool chemicals and miner als in the pool water at any given time Chemical Damage Any damage or corrosion from pool chemicals or any other chemicals used around the heat pump or pool Usu ally concentrated chlorine or acetic water corroding the copper piping or the heat exchanger or other equipment Chemical Resistant Check Valve A check valve placed between the heater and a chlorinator to prevent the migration of concen trated chlorine into the heater Chlorinator A device that is used to feed chlorine to the pool spa through the filtering system Water is pumped through a contain ment holding the chlorine This makes a solution that is then fed to the pool or spa Chlorinator Placement Illustrated in this owners manual show ing the proper location and placement of chlorinating devices in order to prevent chemical damage to the heater
46. nge juice vinegar etc Accumulator a containment housing in the Freon circuit that col lects liquid forms freon that does not evaporate after passing through the evaporator coil thus protecting the compressor from damage Air Blower An electronic device that forces air under pressure through the spa plumbing giving the spa a bubbling effect Air Inlet Used to create bubbling effects for the spa jets Water passing through a vortex draws air into the plumbing without the use of an electronic air blower Usually controlled by some sort of knob or lever to shut it on or off Alkaline Describing pool spa water that is the opposite of acetic with a Ph value above 7 6 Base like milk or chalk etc Anti Short Cycle Time Delay Device Keeps the compressor from being damaged due to the freon gas not being allowed to settle between cycles preventing liquid freon from entering the com pressor When the unit stops there will be a certain time delay before the compressor will start again Automatic Chlorinator A device that feeds either tablet type or liquid type chlorine concentration into the plumbing piping and then delivered to the pool spa water Authorized Factory Service An A C Contractor factory trained and under contract with the manufacturer to provide repair ser vice Back Siphon In regards to pool filtering systems where the water flow reverses through the system when the circulation pump shuts off This is usually caused
47. nit There should be enough clearance to easily service and adjust the heater CAUTION Chemicals should NOT be stored near the heater The fan may draw corrosive chemical vapor through the unit causing damage Do NOT store anything on top underneath or around the heater You will need access to the disconnect breakers in the event of an emergency CONDENSATION DRAINS The unit will produce a condensation of water that will drain from the unit at a steady rate This condensation is from the humidity in the outside air The more humidity the more condensation the unit will produce There are several drain ports in the bottom of the unit make sure they do not become clogged with debris This condensation will attract weeds and insects make sure that the water drains properly and plants are kept trimmed Heat and Cool Models In the cooling mode this unit will produce no condensation The air handling compartment below the fan should be cleaned and vacuumed to remove debris that may clog the condensation drains at the bottom of the heater Accumulated debris will clog the condensation drains causing the water to pool in the bottom of the heater Accumulated condensation water will cause corrosion to the heaters components 14 AIR FLOW Do not install the unit in an area where the cooler discharge air may accumulate and be drawn back into the unit Provide ventilation through containment walls or fencing for the air intake if needed Do not ins
48. ntroduce such into the water flow piping after it passes through the heater as far away from the unit as possible Drain Holes Located in the heater cabinet bottom that allows the condensation water produced normally to drain out Drain Plug A type of valve installed on the plumbing near the heater to allow the heat exchanger to be completely drained of pool water to prevent freeze damage in such climates Dry Acid Powder A dry powder sodium bisulfate used to lower Ph in pool or especially spa water Dual Thermostat A kit added to the unit to allow for two separate thermostats to be used for a pool and spa sharing the same heater Itis also capable of other functions such as motorized valve opera tion Initial Heat Up Time The time required to heat the pool up to the desired temperature when you turn the unit on for the first time When the pool water temperature is at its lowest temperature Electrocution To be shocked by electrical current to have electri cal current pass through your body resulting in death or injury Elevation The height of the installed unit in comparison to the pool water level Evaporation When referring to heat loss of the pool water when the pool water changes from a liquid to a gas then dissipates into the air taking heat away with it Evaporator Coil The aluminum and copper air freon manifold thatis used to change the properties of the Freon as it passes through it The warmer air is for
49. o compensate for added heat loss during the colder months See the diagram on the next page There are four types of heat loss to be concerned with Evaporation accounts for the greatest amount of heat loss As the water changes from a liquid to a vapor it requires heat taken from the pool You are usually heating the pool when temperatures and humidity are low The temperature difference between the pool and outside air increase the evaporation rate Windy conditions will accelerate evaporation heat loss Convection is simply the loss of heat due to the cooler outside air moving across the waters surface Heat moves from hot to cold only so the warmer pool heat transfers to the moving cooler air Windy conditions will acceler ates heat loss Pools and spas located on or nearby open area such as the ocean lakes fields or golf courses will experience increased wind speeds therefore heat loss will be greater for these conditions Evaporation and Con vection account for as much or more than 82 of the total heat loss Conduction is the transfer of heat from the warm pool through the pool or spa shell to the surrounding cooler earth Conduction only accounts for 5 or less of the total heat loss If you live in an area where the ground water surrounds the pool shell and plumbing this type of heat loss will be greater Reradiation is the transfer for heat from the warm pool to the cooler sky Reradiation heat loss will be at it s greatest on clear nig
50. onickel metal alloy This makes the heat exchanger as chemical resistant as possible The heat exchanger will withstand what is considered normal pool water balance Unfortunately chemical damage is usually diagnosed after the unit has failed because the corrosive pool spa water attacks the metal from the inside out WARNING hemical damage to the unit and or heat exchanger in any way is not covered under the warranty agreement The following are water balance specifications that are considered standard pool and spa water testing values and quality These water balance values are the industry standard in which professional pool contractors follow Make sure your pool water is tested and balanced on a weekly basis or more if required Spas will need extra attention See your local pool dealer for help in properly balancing the water chemistry STANDARD POOL WATER inde apt Chlorine Type Actual Ph Effect on Ph ul up Conditions a BALANCE REQUIREMENTS n 2s ae orite Sk liquid c Ph 7 4 to 7 8 D 7 6 Neutral Me urit DEEM tablets or gran A Chlorine Bromine to 5 ppm a 74 ptentorgranutar 6 0 neutran Corrosive conditions i EDUC eo tee 7 0 Acetic 3 Total Alkalinity 90 to 120 ppm pee iom mee Calcium Hardness 250 to 400 ppm r Heat Exchanger Cross Section ADVANCED HEAT EXCHANGER DESIGN Closed Cell Insulation Foam This diagram is a cross section of the heat exch
51. p that does not exceed 90 G P M considering the above you may not need the excessive bypass Excessive water flow can damage the heat exchanger SPECIAL NOTE See chlorinator place ment instructions at the bottom of this page Place plumbing so zt p k access panel can 2 p v c T V C iN be opened j 4 Bypass Pipe Size 2 Py C T 1 5 or 2 pipe 2 H P Ball Valve 2 pipe 3 H P 45 Deg 2H P Pumps Close Bypass 50 3H P Pumps Close Bypass 25 All others must be set by flow meter See Commercial Plumbing Diagram CAUTION Exercise care when installing chemical feeders so as not to allow back siphoning of chemicals into the heater filters or pump The chemical resistant check valve and loop must be in stalled with all types of chlorinators to prevent chlorine migration to the heater The loop should extend at least 8 inches above the chlorinator top The chemical resistant check valve should be placed on the pipe leading up to the chlo rinator Therefore the weight of the water above the check valve will hold it closed even if the spring is weak or dam aged Mount it as low as possible Be sure to keep the chlo rinator pump and filter lid o rings lubricated with silicone grease to insure a good seal If it looses its seal it will allow the chlorine to migrate to the heater when the system shuts To POOL LZ off The loss of vacuum allows reverse flow 19 Heat Exchang
52. quid state in cycles Full Prime A reference used to describe a water pump running normally without air entering into the system running at full ca pacity Gas Chlorine Chlorine in a pure state gas GP M Gallons per minute used to measure flow rate Heat amp Cool The unit the heater the appliance referenced in this manual A reverse cycle unit capable of both heating and cooling Heat Exchanger A manifold where the compressed hot freon gas transfers its heat to the pool water A tube within a tube Hot freon gas passing through one tube and water passing through the other tube bent in a coiled fashion Made from a cupronickel metal alloy Heat Loss The act of the pool losing heat due to certain conditions such as weather wind evaporation radiance convection etc Heat Pump The unit the heater the appliance referenced in this manual Hydro Therapy Jets Used in spas to create high pressure water flow with air turbulence Water is forced through a restriction that creates a vortex that draws air into the water flow thus increasing velocity This air flow is usually regulated by a manual control Icing Up Ice forming on the evaporator coil In Line Type Chlorinator A chlorinating device that is mounted directly on the piping that has an internal manifold within the plumbing used to allow water flow through the containment where a solid tablet type chlorine is held This type requires no water tubing in and out
53. refore the compressor can compress the gas to maximize the gained heat from the air COMPRESSOR Once the fan is running the compressor will start 5 to 7 minutes later and is controlled by a time delay device The compressor pumps and com presses refrigerant gas When gas is compressed it gets very hot and intensifies the energy and then is released to the pool water This com pressed hot gas is pumped through the heat ex changer where it delivers heat to the pool water passing through the same heat exchanger WATER HEAT EXCHANGER The compressed hot gas releases its heat to the pool water inside the heat exchanger The ex changer is a tube within a tube construction wa ter passing through the inner tube and the hot refrigerant passing through the outer tube The refrigerant is transformed into a liquid con densed state as it releases it s heat to the pool water There fore it is also referred to as a condenser coil The alloy exchanger is designed for maximum transfer surface area and strength Cross section FN SYSTEM OVERVIEW NP The heat pump system warm Water Cool Water uses 410 A refrigerant to In Out transfer the heat from the slt am outside air to the pool wa ter Cool Air Out ppt Plumbing Bypass Manifold Warm EROS HP Air E Switch LN NY LP Switch f TEAN Air Coil Refrigerant Lines Exchanger TIME CLOCK SETTING Now that all the filt
54. res are going to be below 36 degrees F you should eliminate the possibil ity of icing and just shut the unit off Do not use the circuit breaker as the on off switch if you want to shut down for a long period of time use the disconnect See page 27 LONG TERM FREEZE PROTECTION DRAIN VALVE INSTALLATION If you live in a climate that has a seasonal swim season due to winter you should follow these long term freezing procedures Spigot Type If you live in an area that experiences freezing temperatures Penn vases the heat exchanger water coil and bypass plumbing must Hose bibb have all water removed to prevent freeze and chemical dam age to the heat pump system This procedure should be done prior to the first freeze along with your other pool winteriz ing routine When you drain the filter system and piping you should include the heat pump as well There should be two spigot type drains hose bibbs plumbed into the heater s water in and water out piping Place Snn ON these valves as close to the heater and at the lowest point Valves Shut the water pump off Close both shut off valves Open both drains and allow water to exit Use pressurized air on the water in one spigot only to force the rest of the water out the other spigot pool equipment may be used see a local pool professional CAUTION Do not add isolation valves unless you intend to clear the heat exchanger of possible so as much water will dr
55. s or in the absence of local codes with the latest national electrical codes ANSI NFPA No 70 For proper wire and or breaker size please refer to specification sheet and your local licensed electrician Always bond heat pump cabinet to pool steel and ground to power supply DUAL THERMOSTAT CONTROL PANEL THERMOSTAT The thermostat dial is just like any other when you set it at a certain setting the heater will heat up to that temperature and then shut off When the pool spa wa ter temperature drops below this setting the heater will come on and start heating the water back up to the setting on the thermostat You will notice there are no number set tings printed on the dial face There is a certain procedure to follow to determine the exact temperature you have the ther mostat set at This is described further on next pages The maximum setting for a thermostat is 104 degrees F You will only be able to reach this high temperature in a spa ap plication Pool temperatures are nor mally between 78 and 82 degrees F Ac tual pool temperatures are determined by your installer when the unit is sized to your specifications The lowest setting on the thermostat is around 60 degrees F To disable the heater turn the thermo stat dial all the way to the left If you live in a climate where the water tem perature may drop below 60 degrees F you must shut the circuit breaker off Otherwise do not use the breaker as an on off s
56. s With Warning Label L E D Display amp Electronic Dual Thermostat Sturdy Elevated Fiberglass Rust Proof Optional Pool Spa Wiring o Bottom En oi Access Holes Easy Connect Fr per Drainage 2 Inch Plumbing With Internal Automatic Bypass Up To 90 GPM TRANE COMPRESSOR And with 410 A the safe SCROLL and clean refrigerant COMPRESSOR Super Quiet amp Highly Efficient Compressor Design 4 DESIGN ADVANTAGES The electrical panel has an isolated compartment located within the mechanical compartment to prevent corrosion The heat from the compressor located just below the electrical compartment helps eliminate moisture as well This exclusive design will substantially extend the life cycle of the heater The fiberglass cabinets is corrosion proof and is much stronger than plastic cabinets Heat Exchanger Special Cupronickel Alloy Encased In A Block of Foam to Prevent Heat Loss amp Corrosion Dual Thermostat L E D Diagnostic Lights Internal Automatic Bypass Free Flow 2 Plumbing Automatically adjusts the water flow Lowest water flow restriction available 2 PVC Water IN 15 90 GPM 2 PVC Water OUT with Elevated Fiberglass Bottom Pan for Proper Condensation Drainage WARNING The heater must be electrically grounded and bonded in accordance with local codes or in the absence of local codes with the latest national electrical codes ANSI NFPA No 70 All wiring must comply with all local code
57. s direction On Off Switch Located on the unit next to the thermostat dial use to shut the unit off and on so you do not have to move the thermo stat or shut off the circuit breaker to control the unit O Ring A round rubber gasket that is used for sealing removable access lids to pool filtering equipment and other related items Ph A term used when determining the alkalinity or acetic nature of water Pool Spa Combination When you have a pool and spa together where the two body s of water are connected by a spill over or other plumbing means PPM Parts per million Use as a term to tell you how much of a certain chemical ratio is in the water Pressure Switch A device inside the heater that senses water pres sure and keeps the unit from running when there is little or no water flow going through it Radiant Heat Loss When the water loses heat through the walls and floor of the pool shell Return The term used to indicate water flow direction back to the pool after it passes through the filtering system There are ori fices in the pool called return outlets Run Dry When any pool equipment is running without water usually causing some sort of damage 32 Serial Number A twelve digit number on the identification sticker on the outside of the heater cabinet Needed for all records war ranty request etc Shadow Box Fence A fence that is made to allow air to pass through it freely without restriction Shock
58. stat is turned all the way up OR Spa is heating very slowly Pool is heating very slowly Pool is not getting up to tempera ture For dual thermostat units Unit is in pool mode but spa is on or unit is in spa mode but pool is on Compressor will not start Fan comes on compressor time de lay passes compressor attempts to start but unit shuts all the way off and or circuit breaker trips Water running from the bottom of the heater when it is running OR The heater seems to have a wa ter leak Low water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumbing valve settings Compressor has not started yet Low water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impel ler Improper plumbing valve settings Low or restricted water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumb ing valve settings Suction leak allowing air into the water flow Low water flow when switched to spa mode or the control is not in spa mode Unit is plumbed backwards Heat exchanger clogged with debris Internal bypass valve damaged or clogged with debris Your spa thermometer is not reading the correct tempera ture Air blower is running Venturi air inlets are open It is very cold outside Spa pump is not running Low or restricted water flow through heater Dirty
59. sure your pressure gauge is kept in good working condition Locking Nut amp PSI G cdi g O Ring 1 ox 7 N Gauge Air Bleed Valve lt gt orn Typical Cartridge Filter j Element Filter Tank There are some after market filter element cleaning so lutions that will help remove oil and minerals that may clog the filter Oil and minerals can not be removed with normal cleaning and back washing Spas are par ticularly susceptible to oil build up in the filter Do not acid wash a filter until you have removed all oil and grease with a solution designed to remove such Acid washing a filter with oil in it will cause that oil to be come permanently embedded in the fibers Cartridge filter element replacement is suggested every 1 to 2 years Sand filters should have the sand replaced every 3 to 5 years D E type filter elements should be re moved and soaked in a solution at least every two years AUTOMATIC POOL VACUUMS Automatic pool cleaners will decrease the water flow by restricting the suction of the circulation pump Most automatic type pool cleaners operate from the suction provided by the circulation pump Some automatic pool vacuums are plugged into the skimmer suction port The main floor drain is then re stricted some so that the auto vac has enough vacuum to operate It can then move freely and not become stuck to the main drain port Typical Automatic Poo
60. t of a filtering system that holds a specific amount of water to supply the circulation pump Filter elements are some times placed in this tank so when the pump suctions water through them itcleans the water This tank is fed pool water through plumb ing piped from the pool by gravity Temperature Rise Difference A calculation used to determine how many degrees the water passing through the heat exchanger is in creased in order to set it at a prescribed difference Thermometer Used to determine the actual pool or spa water tem perature Sometimes a floating type or a tie on type Thermostat Located on the unit itself used to set the desired tem perature you would like the actual pool or spa water to be The unit will activate if the water temperature is below the set ting The unit will shut off when the water temperature has reached that particular setting Three Way Valve A plumbing valve that controls water flow hav ing three ports in which to connect plumbing to Timer A timing device that activates the water circulation pump according to preset times Time Delay A device inside the heater that will delay the com pressor from running until the refrigerant gas and crank case oil settle before allowing the compressor to run preventing damage to the compressor Trickle Type Sprinkler An irrigation distributor that does not broad cast water into the air but slowly waters the surrounding ground directly Vacuum T
61. t when you open air the bleed valve you may have a vacuum leak Vacuum leaks that allow an accumulation of air in the filter and will cause the system to lose prime when the pump is off and allow reverse flow Reverse flow may allow chlorine solution to migrate to the heat ex changer Vacuum leaks will cause premature wear to the heat ex changer The air allowed into the system causes turbu lence in the heat exchanger The result is physical ero sion to the metal alloy water channel Note Chlorine solution is heavier than water and will migrate through the plumbing even if there is no vacuum leak CHLORINATOR PLACEMENT 1 All chlorinators should have a chemical resistant check valve and a loop plumbed at least 8 inches above the chlorinator between it and the heater as far down line from the heater as possible 2 Never plumb a chlorinator into the suction side of the circulation pump All automatic chemical feeders should be as far down line of the heaters water flow as possible 3 Off line type chlorinators should be tapped into the plumbing only as shown on the diagram See pool spa combinations requiring special placement See plumb ing diagram 4 Never install a chlorinator at a higher elevation than the lowest heater piping even if a loop check valve is used Doing so may allow chlorine to migrate to the heat exchanger causing damage 5 Do not allow floating chlorinators to be drawn up to the skimmer inlet
62. tall this unit indoors or in filtering system equipment rooms Do not restrict the air flow in any way ROOF RUN OFF To prevent large amounts of rain water from running through the unit you may need to install a gutter and down spout when the roof has a sharp pitch IMPORTANT Do not allow roof run off water to rush through the unit Do not install the unit under roof valleys where two roof sections meet The two roof sections channel water to the valley and will allow massive amounts of water to run through the unit at high velocity CLEANING To clean the heater you should take a sponge and mild soapy water and wipe the surfaces clean Do not use a pressurized garden hose to clean the heater Never force water into the unit from any direction You may use a garden hose at low pressure with no nozzle attachment Clean the evaporator coils at least twice a year If you live near the sea coast you will need to clean at least four times a year to remove salt and sand Use a very soft brush with soap and gently remove any build up Clogged evaporator coils will reduce the efficiency of the unit and cause corrosion Use a fin comb to straighten any minor indentations in the evaporator coils 25 Maxi mum Roof Pitch OPEN Without A lH Do not allow roof run off to flow into the unit Air Flow Out Service Access L2 4 to 367 Evaporator Slab Coils WATER PIPING LEAK When the unit operates it will produce condensation that will
63. talling a heat pump are somewhat higher than a gas heater but you will save enough in opera tional costs to offset the difference probably in the first year or two After a few heating seasons you will have saved enough compared to LP gas heat to pay for the entire heat pump and installation LONGER SWIMMING SEASON A heat pump is the least expensive way to heat your pool It will out perform solar by delivering heat on demand no matter how much sunshine is available A solar system with a gas back L P Gas back up will cost more to operate than the heat pump alone In Florida a heat pump offers a full 12 months of swim ming season compared to a solar systems 10 month swimming season A heat pump will provide higher temperatures than a solar system Solar will not heat a spa on demand after sundown amp during inclement weather LOW MAINTENANCE Maintenance cost can be more for a gas heater consid ering the fact that a gas heater starts to lose efficiency as it gets older The heat pump s sealed system needs far less attention SPECIAL FEATURES Separate Air Handling Electric Compartment An internal electrical compartment substantially reduces future service from moisture and salt laden air flow Sturdy Rust Proof Quiet Fiberglass Top High Volume Non Fading Fan With Vinyl Coated Guard Large Aluminum amp Copper Product Lanced Fin Name Plate Evaporator Air Coil and Coil Guard Chemical Automatic Diagnostic
64. tion leak allowing air into the water flow Internal water pressure switch failure Control Ready light ON Water Press OK light OFF T Stat On light OFF Low amp High Press lights OFF Unit will not start Control Ready light ON Water Press OK light ON T Stat On light OFF Low amp High Press lights OFF Unit will not start Control Ready light ON Water Press OK light ON T Stat On light ON Low Press light OFF High Press light OFF Unit will not start OR Unit is forming ice or frost on the outer air coil usually at the bottom Control Ready light ON Water Press OK light ON T Stat On light ON Low Press light ON High Press light OFF Unit will not start Control Ready light ON Unit is cycling on amp off Thermostat is not set higher than the pool spa water temperature The water temperature has reached the maximum setting The thermostat is malfunctioning Dual thermostat the pool spa select switch is not in the correct mode Outside air temperature below operating range of 45 F unit is in defrost mode Discharge air flow is restricted Discharge air is accumu lating and being drawn back through the outer air coil The fan is obstructed low air flow Large amounts of roof run off water restricting fan blade rotation Sprinklers spraying on the outer air coil during cooler temperatures Outer air coil clogged with debris Plants too close to heater blocking air flow Low refriger
65. ts Corrosive pool water chemical dam age to water tubing inside heater Chlorinator is not isolated from the heater chlorine migration Clean entire filtering system and or replace fil ter element Inspect amp clean pump impeller Adjust plumbing valves Call the factory for advice Wait for the 5 minute compressor time delay Clean entire filtering system and or replace fil ter element Inspect amp clean pump impeller Adjust plumbing valves Call factory or dealer Clean entire filtering system and or replace fil ter element Inspect amp clean pump impeller Adjust all plumbing valves Repair suction air leaks grease pump lid o ring Shut off air blower and or Venturi inlets that allow air tur bulence in the spa Use a cover while heating the spa Outside air temp too cold Set spa pump timer for longer time Call your dealer for advice Call the factory for advice Clean entire filtering system and or replace fil ter element Inspect amp clean pump impeller Adjust all plumbing valves Repair suction air leaks grease pump lid o ring Use a pool cover Place a wind break around pool Set pool pump timer longer Call your dealer for advice Call the factory for advice Use the motor valve actuator switches so the valves go to the mode selected on the dual ther mostat pool spa select switch Grease motor valves Adjust manual valves correctly Ad just third party control device Possible defec tive motor valve
66. u want to prevent any chemicals from running through the piping and heat exchanger of the unit Chlorine so lution will damage the heat exchanger Some chlori nating devices inject chlorine solution through the suc tion side of the filtering system thus the chlorine passes through the heat exchanger at full strength before it has a chance to mix and dilute with the rest of the pool wa ter Also note The overall chemical balance of the pool water will directly effect the life of the heat exchanger CHLORINE MIGRATION Some chlorinating devices will back siphon when the system is shut off therefore allowing the chlorine solu tion to migrate through the heat exchanger causing dam age You have to make sure your filtering system does not have a vacuum leak that would allow the system to lose prime When this happens water will move back wards through the chlorinator thus moving the chlorine solution into the heat exchanger Note Chlorine solu tion is heavier than water and will migrate through the plumbing even if there is no vacuum leak 22 VACUUM LEAKS Suction leaks that allow air into the system when the pump is running will cause damage to the heat ex changer Suction leaks are what cause the system to back siphon or reverse flow Make sure that all the o ring seals in the pump lid filter and chlorinator are in good condition and are lubricated with silicone grease If your filter repeatedly has excessive air inside i
67. witch See Start up Procedures regarding compressor preheating if the main power breaker is shut off The compressor must be preheated for 8 hours after the power supply has been disconnected DUAL Thermostat LI En Mr GLITE TTT E E it Lit iiil L E D Status Lights See page 7 for details L E D STATUS LIGHT PANEL The indicator lights will help you determine that the unit is running normally or if there is a condition that may keep the heater from running Note that the spa light is inactive on single thermostat units See next page for details on reading the status lights L E D STATUS LIGHT PANEL Control Ready Green The green control ready indicator light lets you know that the heater has power and it is ready to heat This light must be on before the heater can run If this light is off check you power supply and circuit breakers If this light is off none of the others will light either CAUTION The unit may still have live voltage when the control light is off NOTE The bottom four indicator lights work in sequence from left to right To use indicator lights see troubleshooting guide pages 26 amp 27 POOL MODE Yellow The yellow pool mode indicator light lets you know that you have selected the pool mode with the pool spa select switch dual thermostat control only This light will be off when the control is in spa mode SPA MODE Orange The orange spa mode indicator light tells you that
68. ype Filter A filter on the suction side of the circulation pump usually mounted inside a surge tank Water is drawn through the filter media trapping debris Variable Rate Flow Control Valve The internal valve used to as a bypass for the heater water flow This spring type valve will automatically adjust the water flow rate to the unit when the flow rate changes for what ever reason 30 to 70 G P M range Water Coil Same as heat exchanger Water Chemical Balance The standard pool water test and chemi cal amounts and values that the water needs to be considered bal anced according to standard practice 33 This page is blank 34 This page is blank 35 Pool Products Because reliability Manufactured by 2003 Pentair Pool Products Inc 1620 Hawkins Avenue Sanford NC 27330 10951 West Los Angeles Avenue Moorpark CA 93021
69. ystem in the wrong place you can run full strength chlo rine through the heat exchanger before it has a chance to mix with the rest of the pool water See the next section on chemical usage and chlorinator placement Shock Treatments A shock treatment is a large dose of chlorine added to the pool water all at once to reduce the amount of combined contaminated chlorine in the water or to kill algae Make sure you do not over shock treat calculate the exact amount of chlorine needed When shock treating the pool make sure that the pH levels remain at the prescribed levels after the chlorine is introduced Do not add any more chlorine to the water until the chlorine levels have dropped to normal Prolonged high chlorine levels will cause damage to the heat exchanger The combination of high chlorine and low pH acetic will deteriorate the heat exchanger at an accelerated rate Do not add shock treat ment or chlorine tablets in the skimmer Read and follow the chemical manufacturers directions when adding chemicals unless they conflict with this book let Contact your dealer or the factory service department for advice 21 pH The pH level in your pool should be maintained within the range of 7 4 to 7 8 A pH test will tell you how acetic or how alkaline the pool water is For example acetic like orange juice or alkaline like milk A 7 6 pH is considered the middle of the road Lower than 7 6 means that the water has an acetic tend