Home
Pentair C40 User's Manual
Contents
1. IntelliChlor Models The IntelliChlor salt chlorinator system models are e PC 100 P N 520556 Power Center Kit IC 20 Cell P N 520554 Designed for pools up to 20 000 U S gallons 75 liters this cell will produce approximately 0 70 pounds of chlorine per 24 hour period This cell uses two terminal blades and five bi polar blades making this system more cost competitive e IC 40 Cell P N 520555 Designed for pools up to 40 000 U S gallons 151 liters the cell will produce approximately 1 40 pounds of chlorine per 24 hour period This cell uses 3 terminal blades and ten bi polar blades five on each side of the center terminal blade This will supply more than enough chlorine for almost any residential and many smaller commercial pools e IntelliChlor pass through cell P N 520588 For new pool start up IntelliChlor Power Center Installation Guide Operating Instructions When using a pool pump timer The Association of Pool and Spa Professionals APSP recommends that all water in a residential pool pass through the filtration system at least once every 12 hours referred to as pool water turnover However many factors have an effect on actual pump and filter system run times Pool size source of water direct sun light indoor outdoor screened and unscreened filtration system cold or hot weather swimmer load rain organic debris algae etc are all factors which contribute to either more or less pool pump and filter
2. Pentair Water Pool and Spa IntelliChlor Power Center For use with IntelliChlor model IC20 and IC40 Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2006 Pentair Water Pool and Spa Inc All rights reserved This document is subject to change without notice 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 805 553 5000 Trademarks and disclaimers IntelliChlor IntelliTouch EasyTouch and the Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Pentair Water Pool and Spa Inc disclaims proprietary interest in marks and names of others P N 520590 Rev C 04 28 06 Contents IMPORTANT SAFETY PRECAUTIONS ica doter a tuae lr dados ii Installation Steps SUMIMANY cistitis iii Technical Support ossia M iii Mairo ttle iray Era EET E N E AE E E A E E E T E T 1 Power Center OvV rVio Wersi sanen ana a oa ies 1 IntelliChlor Models anaa E aE EAE AES ANAE E KAN Ea eaaa AE dran rns sein AEA EENAA rennen 1 Operating Instr ctions iii crest cerit te ac inh edith Dec edie eit Bee vu bie ei ede 2 e EE TILA y DEPP PO gg iii 2 Kit Contents orina niin degli aE ie a LL 2 Required TOONS car
3. and or material in any item covered by this warranty become evident during the term of the warranty then upon the consumer following the procedures set forth below Pentair Water will at its option repair or replace such item or part at its own cost and expense Pentair Water is not however responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service Department Also Pentair Water is not liable for any loss of time inconvenience incidental expenses such as telephone calls labor or material charges incurred in connection with the removal or replacement of the equipment or any other incidental or consequential damages PLEASE NOTE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you No Other Warranties TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTAIR WATER DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Procedure for Obtaining Performance In order to obtain the benefits of this warranty the consumer who made the original retail purchase must contact the Pentair Water Technical Service Department upon discovery of the defect but in no event later than the expiration date of the warranty period provided in this warranty Upon receipt o
4. high flow applications use a bypass loop IntelliChlor Power Center Installation Guide Installing the Power Center Install the Power Center at eye level as close to the IntelliChlor pump and filtration as possible CAUTION The Power Center must be installed more than 8 ft 2 44 m from the pool edges Leave sufficient clearance on all sides of the Power Center Ensure that the 15 ft 4 61 m DC power cord from the Cell assembly pipe location can reach the Power Center location The Power Center enclosure can be mounted on the wall up to 15 feet away from the cell controller Note For installation instructions about connecting the cell to Power Center see the IntelliChlor User s Guide P N 520589 Mount the Power Center enclosure 1 2 Remove the screw securing the Power Center cover and remove the cover Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location There are two 2 screw holes and a keyslot for the top and lower bracket Drill six 4 inch 6 35 mm holes Install anchors if necessary and one screw for each bracket keyslot location Position each Power Center keyslot top and lower slot over the two mounting screws just installed Tighten the two screws to secure the enclosure Install and tighten four mounting screws two in the top and two in the lower bracket Bracket keyslot Bracket screw hole Bracket screw hole Cover scre
5. pump side of the relay located in the IntelliTouch Load Center This method does not require a ground fault circuit interrupter GFCI to protect the circuit 220 VAC Basic Svstem Wirinc L PUMP TIMER 240V WIRING Circuit Breaker Panel POWER CENTER 240 VAC 50 60 Hz Transformer YELLOW VIOLET BLACK 20 Amp 2Pole GFCI WHITE 110 VAC Basic System Wiring POOL PUMP TIMER 110V WIRING Circuit Breaker Panel POWER CENTER 110 VAC 50 60 Hz Ta Transformer LINE 1 y Leads 20 Amp 2Pole ER GFCI GROUND il IntelliChlor Power Center Installation Guide Notes IntelliChlor Power Center Installation Guide LIMITED WARRANTY Pentair Water Pool and Spa Inc Pentair Water manufactures its products with the highest standards of workmanship using the best materials available through state of the art process Pentair Water warrants its products as follows Limited Warranty Pentair Water warrants its products to be free from defects in material and or workmanship for a period of three 3 years or 8 000 hours parts only from the original date of installation Exceptions that could result in denial of a warranty claim 1 Damage caused by careless handling improper repackaging or shipping 2 Damage due to misapplication misuse abuse or failure to operate equipment as specified in the owners manual 3 Damage caused by failure to install produc
6. RNING Do not operate electrolytic cell without proper flow or water circulation A build up of flammable gases will result in hazardous conditions E A CAUTION When using IntelliChlor with an IntelliTouch system it is recommended to wire the IntelliChlor Power Center to the pump side of the relay located in the IntelliTouch Load Center This wiring method does not require a ground fault circuit interrupter GFCI to protect the circuit A green colored terminal or a wire connector marked G GR Ground or Grounding is provided within the terminal compartment in the Power Center transformer enclosure To reduce risk of electric shock connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment The power supply must be interconnected with pool pump motor power source This insures the IntelliChlor chlorinator and pool pump will switch on and off together CAUTION Use of chemicals other than those recommended may be hazardous Follow the Chemical Manufacturer s Instructions AACAUTION Install the IntelliChlor unit a minimum of two 2 feet from the heater outlet AACAUTION It is recommended to install a Pentair 2 CHECK VALVE P N 263042 between the input side of the IntelliChlor cell and the main heater output pipe IntelliChlor Power Center Installation Guide Declaration
7. SULT IN SERIOUS INJURY OR DEATH Before attempting installation of service ensure that all power to the circuit supplying power to the system is disconnected switched off at the circuit breaker When using IntelliChlor with an IntelliTouch system it is recommended to wire the IntelliChlor Power Center to the pump side of the relay located in the IntelliTouch Load Center This wiring method does not require a ground fault circuit interrupter GFCI to protect the circuit A green colored terminal or a wire connector marked G GR Ground or Grounding is provided within the terminal compartment in the Power Center transformer enclosure To reduce risk of electric shock connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment The power supply must be interconnected with pool pump motor power source This insures the IntelliChlor chlorinator and pool pump will switch on and off together e Grounding earth bonding is required The unit should be installed by a qualified service person and grounded A CAUTION Install the IntelliChlor unit a minimum of two 2 feet from the heater outlet e Allow ample access to the IntelliChlor control panel buttons and the IntelliChlor Power Center e Pipe couplings Schedule 80 maximum pressure 150 psi at 70 F e Operate unit with minimum flow of 20 gpm For
8. ch incoming power wires 12 14 AWG 3 wire to Power Center AC power wires Conduit knockout for AC power cable source Ground bonding lug Troubleshooting Note Turn off power to unit before attempting to service or repair Problem Possible Cause Corrective Action The IntelliChlor green Fuse in Power Center is open Replace 8 AMP slo blo fuse located at bottom power light on the of Power Center control panel is not on No AC power to Power Center Verify time clock is providing 110 VAC or 220 VAC to Power Center when active Tansformer leads not wired correcly in Power Verify transformer leads wired to AC source by Center referring to wiring diagram decal on inside of Power Center cover IntelliChlor Power Center Installation Guide Electrical Specifications and 110 VAC and 220 VAC Wiring Circuit Protection Two pole 20 AMP device at the electrical panel IntelliChlor Model IC20 Input 90 130 VAC 50 60 Hz 220 Watts 2 AMP or 220 240 VAC 50 60 Hz 220 Watts 1 AMP Output 22 39 VDC 6 AMPS maximum from the Power Center Chlorine 0 70 Ib 24 hour 317 gm 24 Hour IntelliChlor Model IC40 Input 90 130 VAC 50 60 Hz 220 Watts 2 AMP or 220 240 VAC 50 60 Hz 220 Watts 1 AMP Output 22 39 VDC 6 AMPS maximum from the Power Center Chlorine 1 40 Ib 24 Hour 635 gm 24 Hour IMPORTANT When using IntelliChlor with an IntelliTouch system it is recommended to wire the Power Center to the
9. e IntelliChlor electrolytic cell to operate and create chlorine for the swimming pool and spa The Power Center is connected with the pool circulation pump electrical source so that the electrolytic cell only operates when the pool pump is on It is recommended that a pool pump timer be used to save on energy and prolong the service life of your pool pump and IntelliChlor A timer is not included as part of the Power Center kit The IntelliChlor Power Center can be connected to an IntelliTouch or EasyTouch system for automation control The Power Center enclosure can be mounted vertically on a flat surface such as a wall or post no more than 15 feet away from the cell controller The Power Center houses the transformer fuse and connector to the cell 110 VAC and 220 VAC wiring is connected at this box with 35 VDC output to the cell controller A 8 AMP slo blo fuse is mounted on the bottom of the enclosure for additional protection There are no other controls or lights on the outside of the Power Center A green power LED indicator is mounted on the inside main board When the Power Center is switched on the power LED is lit Transformer Internal Ground lug Screw terminal to EasyTouch and IntelliTouch systems Attach incoming AC wire to Power Center AC power wires blue and brown 7 Fuse 8 AMP slo blo fuse Lug Ground bonding Cell connector IntelliChlor Power Center model PC 100 cover removed Power LED indicator
10. f this communication Pentair Water will promptly notify the customer of the address to which the defective item may be shipped The customer shall then ship the item freight prepaid to the address indicated together with a RETURN GOODS AUTHORIZATION form obtained from Technical Service and a brief description of the problems encountered Unauthorized returns will not be accepted Freight must be prepaid by customer Warranties or Representations by Others No dealer or other person has any authority to make any warranties or representations concerning Pentair Water or its products Accordingly Pentair Water is not responsible for any such warranties or representations Other Rights This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all previous publications PENTAIR WATER POOL AND SPA INC 1620 Hawkins Ave Sanford NC 27330 10951 W Los Angeles Ave Moorpark CA 93021 Phone 800 831 7133 Fax 800 284 4151 Pentair Water Pool and Spa P N 520590 Rev C
11. of Conformity We declare under our sole responsibility that the product identified in this declaration and to which this declaration relates are in conformity with the protection requirements of Council Directive 89 336 EEC and standards IP33 e Standard EN60335 1 2001 EN60529 e Standard EN6100 3 2 2000 EN6100 3 3 1995 A1 2001 e Standard EN 55014 2 1997 A1 2001 EN 55014 1 2000 A1 A2 2002 Manufacturer Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 10951 West Los Angeles Ave Moorpark CA 93021 Installation Steps Summary The recommended Power Center installation steps are 0 Review Important Safety Precautions page ii and 2 Review this important information O Review Power Center Overview page 1 Review the Power Center overview information o Installing the IntelliChlor Power Center page 2 Installation information O Operating Instructions page 2 Operating information Technical Support Contact Technical Support at Sanford North Carolina 8 A M to 5 P M Phone 800 831 7133 Fax 919 566 8920 Moorpark California 8 A M to 5 P M Phone 800 831 7133 Fax 805 530 0194 Web sites visit www pentairpool com and www staritepool com IntelliChlor Power Center Installation Guide Power Center Overview The IntelliChlor system comprises of a Power Center and electrolytic Cell The Power Center converts AC electrical current to a low voltage DC current required by th
12. system run times Because of these differences it is extremely difficult to set an initial run time starting point for the pool pump and chlorinating system Try initially setting the pool pump timer to 12 hours It will take a few days to get just the right amount pool pump operating time When the Chlorinator is wired with a pool pump timer see page 6 results will vary greatly from one pool installation to the next so this should be discussed with either the pool builder or your pool professional Installation The following information describes how to install the IntelliChlor Power Center Before installing review the IntelliChlor kit contents and required tools For cell installation instructions see the IntelliChlor User s Guide P N 520584 Kit Contents One Power Center Installation Guide this manual Required Tools Phillips amp Flathead Screwdrivers Voltmeter To determine AC line voltage to Power Center Electric drill and 1 4 masonry drill bit To mount Power Center WARNING IMPORTANT SAFETY PRECAUTIONS PLEASE READ THE FOLLOWING Read all the safety precautions in this manual before attempting any electrical wiring AN Be sure to read and follow all safety Instructions on page ii Wiring should only be performed by a qualified professional When using electrical products basic precautions should always be followed including the following A WARNING RISK OF ELECTRIC SHOCK WHICH CAN RE
13. ta EE 2 SAFETY PRECAUTION Sii ad dc 2 Installing the Power Center i 3 Troubleshooting iraniana A A air 5 Electrical Specifications and 110 VAC and 220 VAC Wiring conan cra nannnn rca 6 220 VAC Basic System Wiringt ilaele ani calare iaia ai 6 10 VAC Basic System WINN sisaria agia e ea a a a a 6 IntelliChlor Power Center Installation Guide IMPORTANT SAFETY PRECAUTIONS SAVE THESE INSTRUCTIONS 7 Important Notice Attention Installer This manual contains important information about the installation operation and safe use of this product This information should be given to the owner and or operator of this equipment A WARNING IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS 0 Before installing this product read and follow all warning notices and instructions gt which are included Failure to follow safety warnings and instructions can result in severe injury death or property damage Call 800 831 7133 for additional free copies of these instructions A WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times A WARNING When mixing acid with water ALWAYS ADD ACID TO WATER NEVER ADD WATER TO ACID A WARNING To reduce the risk of injury service should only be attempted by a qualified Pool Service Professional A WA
14. ts as specified in the owners manual 4 Damage due to unauthorized product modifications or alterations or failure to use Pentair Water original replacement parts 5 Damage caused by negligence or failure to properly maintain products as specified in the owners manual 6 Damage caused by failure to maintain water chemistry in conformity with the standards of the swimming pool industry for any length of time 7 Damage caused by water scaling freezing or other conditions causing inadequate water circulation 8 Accidental damage fire acts of God or other circumstances outside the control of Pentair Water e This warranty extends to the original retail owner only beginning on the date of installation and is not enforceable by any other party Proof of purchase and or date of installation will be required to execute a warranty claim Original owner agrees to repay all shipping charges to Pentair Water Pool and Spa Inc e Warranties by others Some products incorporate components manufactured by other manufacturers Some of these provide warranties in addition to the warranty provided herein In all such cases a copy of that warranty will be provided with the product To the extent protection provided under any such third party warranty exceeds the Limited Warranty provided herein the Customer will have to look to that manufacturer for the additional warranty protection Warranty Obligations of Pentair Water Should a defect in workmanship
15. w hole Bracket screw hole Bracket screw hole Bracket keyslot IntelliChlor Power Center Installation Guide Connect AC power to the Power Center 6 Use 12 14 AWG three conductor insulated wire for the main AC power connection Connect the Power Center to pool pump AC power source The Power Center should be connected to the pump motor switch or automatic timer For system wiring information see page 6 7 Attach incoming GROUND wire to the ground lug inside the Power Center 8 Earth Bonding Grounding Connect the earth wire to the GROUND BONDING LUG located on the bottom of the Power Center enclosure Earth bonding is necessary to ensure personal safety and safety of equipment IMPORTANT A number 8 gauge 8 4 mm wire is recommended when connecting the power supply to a Permanent Earth Ground connection that is acceptable to the local inspection authority Attach the bonding point located on bottom of the Power Center to a Common Earth Bonding Point Do not use the IntelliChlor as the Common Bonding Point Each piece of non chlorinator pool equipment requiring a ground should be bonded to the Common Approved Earth Bonding Point Never ground pool pump to Power Center 9 Reinstall the Power Center cover and secure with the cover screw 10 The Power Center installation is complete For IntelliChlor operating information refer to the IntelliChlor User s Guide P N 520589 Connect incoming ground wire to GROUND lug Atta
Download Pdf Manuals
Related Search
Related Contents
Fusion V-AD-A5-0-ORB Instructions / Assembly Samsung 214T Hướng dẫn sử dụng ARP Omni Service Manual Approx APPP180T projection screen Superstar Nudge - J-h NFPA 1500 Anexo F Información sobre EPP para Materiales Tensoval Duo Control II BISモニタ A-1050 Canon XG A1 Camcorder User Manual Copyright © All rights reserved.