Home

Pelco Receiver C1506M User's Manual

image

Contents

1. fie 6 j 24V Bed le w PAN TILT CAM PWR LENS AUX1 AUX2 Connect the pan tilt controls up down left right and common Connect the camera power If your camera uses 24 VAC connect the camera to the CAM PWR connector on the front of the re ceiver The camera s power must not exceed 5 vA If your camera uses 115 or 230 VAC connect the camera s power leads to the Enclosure Power Out terminals inside the receiver The camera s power must be the same as the receiver s power Main Power In terminals Connect the motorized lens controls iris focus Zoom and common Connect video VIDEO IN comes from the camera VIDEO OUT goes to the controller If necessary refer to Table B in the Wiring Tables section to determine appropriate coaxial cable types for video applications Connect the auxiliary outputs optional AUX 1 is a 5 VDC 20 mA maximum open collector output Use the auxiliary To operate low current relays To turn on or off a Pelco window wiper that has TTL circuitry AUX 2 is a normally open normally closed Form C relay Relay contacts are rated at 1A maximum at 24 VDC or 5A maximum at 115 VAC Double check all wiring connections and then turn on power Pelco Manual C1506M 3 00 5 IRD2024 WIRING Rear View of Receiver f M 115 230 SN UJ M P T SELECT Es ERD OPTION IN
2. Pan Man or Manscan key Extended Coaxitron Activate random auto scanning by calling the following presets Preset 97 Random scanning Preset 98 Continuous auto scanning see WARNING below Preset 99 Auto scanning with half hour timeout after which pan tilt switches to random scanning Preset 96 Stop scanning WARNING Activating preset 98 continuous auto scanning reduces the warranty on your pan tilt to six months Auxiliary Operation Operation of the two auxiliaries varies depending on the transmitter controller you are using and whether itis communicating in standard or extended Coaxitron mode Refer to your transmitter controller manual for the exact key press sequence required to send an Aux 1 or Aux 2 command The following explains how the auxiliaries respond with the different Coaxitron modes Standard Coaxitron When a valid Aux 1 or Aux 2 command is received the corresponding auxiliary operates momentarily Extended Coaxitron When a valid Aux 1 or Aux 2 command is received the corresponding auxiliary operates momentarily Optional Latching Mode Extended Coaxitron Only When a valid Aux 3 or Aux 4 command is received the corresponding auxiliary performs a latching operation NOTE Aux 3 operates Aux 1 and Aux 4 operates Aux 2 Pelco Manual C1506M 300 7 FUSE REPLACEMENT IRD2024 Lens Auxiliary Fuse A500 mA fuse protects the LENS and AUX 1 outputs Remove the cover of the receiver to check the
3. from the controller The TLC module will override any signals from the controller 8 Pelco Manual C1506M 3 00 WIRING TABLES Table A 24 VAC Wiring Distances Table The following are the recommended maximum wire distances transformer to load for 24 VAC applica tions and are calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Distances are calculated in feet values in parentheses are meters Wire Gauge 20 18 16 14 12 10 10 283 86 451 137 716 218 1 142 348 1 811 551 2 880 877 20 141 42 225 68 358 109 571 174 905 275 1 440 438 30 94 28 150 45 238 72 380 115 603 183 960 292 40 70 21 112 34 179 54 285 86 452 137 720 219 50 56 17 90 27 143 43 228 69 362 110 576 175 g o 47 14 75 22 119 36 190 57 301 91 480 146 E m 40 12 64 19 102 31 163 49 258 78 411 125 80 35 10 56 17 89 27 142 43 226 68 360 109 2 90 31 9 50 15 79 24 126 38 201 61 320 97 100 28 8 45 13 71 21 114 34 181 55 288 87 110 25 7 41 12 65 19 103 31 164 49 261 79 120 23 7 37 11 59 17 95 28 150 45 240 73 130 21 6 34 10 55 16 87 26 139 42 221 67 140 20 6 32 9 51 15 81 24 129 39 205 62 150 18 5 30 9 47 14 76 23 120 36 192 58 EXAMPLE An enclosure that requires 80 vA and is i
4. fuse ERD2200 Main Fuse The main fuse protects the pan tilt output when 24 VAC panltilt operation is selected It also protects the 24 VAC camera output Refer to the EA 2200 Wining section for fuse location and values Enclosure Fuse The enclosure fuse protects the pan tilt output when 115 230 VAC pan tilt op eration is selected It also protects the enclosure output Refer to the D2200 Wiring section for fuse lo cation and values Lens Auxiliary Fuse A500 mA fuse protects the LENS and AUX 1 outputs Remove the cover of the receiver inside the housing to check the fuse TROUBLESHOOTING Check the wiring connections If the CX LED does not blink when commands are sent to the receiver make sure the controller is work ing properly Also check the video coaxial cable between the controller and the VIDEO OUT connection on the receiver An LRD41TLC Test Local Control Module is available from Pelco to test or troubleshoot your receiver pan tilt and lens functions directly from the receiver This lightweight hand held keypad tests the up down left and right functions of the pan tilt and the iris open close focus near far and zoom telephoto wide functions of the lens 1 Plug the module into the TLC connector on the front of the receiver The module can be plugged in with the receiver s power turned on 2 Pushthe buttons on the keypad to test your equipment The TLC module can be used without discon necting the receiver
5. PELCO Installation Operation IRD ERD2000 Series Receiver C1506M 3 00 C Pelco 300 W Pontiac Way Clovis CA 93612 5699 USA Pelco Online www pelco com In North America and Canada Tel 800 289 9100 FAX 800 289 9150 DataFAX 800 289 9108 International Customers Tel 1 559 292 1981 FAX 1 559 348 1120 DataFAX 1 559 292 0435 PelcoEurope BV Dillenburg Center Dillenburgstraat 5F 5652 Eindhoven The Netherlands Tel 31 40 251 9870 FAX 31 40 251 9835 IMPORTANT SAFEGUARDS AND WARNINGS Prio 1 T The r to installation and use of this product the following WARNINGS should be observed Installation and servicing should only be done by qualified service personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is de signed for indoor use only and it must not be installed where exposed to rain and moisture Only use replacement parts recommended by Pelco The installation method and materials should be capable to supporting four times the weight of the re ceiver Use stainless steel hardware to fasten the unit to outdoor surfaces If the unit requires 120 230 VAC and does not have an on off switch the input power circuit must have a circuit breaker For continued protection against risk of fire replace fuses only with the same type fuses product and or manual
6. PUT 8 Sa 24 VA Front View of Receiver f 21 E Pa o i O n cc 24Vie FZC As ONN nee eal Cee aa me PAN TILT CAM PWR LENS AUX1 AUX2 1 Connect power to the 24 VAC INPUT connector on the rear of the receiver The receiver s power re quirement is a maximum of 5 vA not including the camera and pan tilt Refer to the pan tilt manual for its power requirements Do not turn on power If necessary refer to Table A in the Wiring Tables section to determine appropriate wire sizes for 24 VAC applications 2 Make sure the P T SELECT switch on the rear of the receiver is set toward 24 VAC The 115 230 VAC Switch position is used only with the ERD2200 3 Connectthe pan tilt controls up down left right and common 4 Connect the camera power 24 VAC 5 Connect the motorized lens controls iris focus Zoom and common 6 Connect video VIDEO IN comes from the camera VIDEO OUT goes to the controller If necessary refer to Table B in the Wiring Tables section to determine appropriate coaxial cable types for video applications 7 Connect
7. andard motorized or fixed focal length lenses Two years on Legacy Camclosure Camera Systems CM6700 CM8500 CM9500 CM9750 CM9760 Matrix PelcoVision DF5 Series and DF8 Fixed Dome products Two years on Spectra and Esprit including when used in continuous motion applications Two years on WW5700 series window wiper excluding wiper blades Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Prod ucts Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liabil ity relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dea
8. ches 38 6 x 31 0 x 12 7 cm Weight 9 90 Ib 4 50 kg CERTIFICATIONS RATINGS CE Class A UL cUL pending NEMA 4 IP 66 pending 10 Pelco Manual C1506M 3 00 IRD2024 ELECTRICAL Input Voltage 24 VAC 50 60 Hz Output Voltage Camera and Pan Tilt 24 VAC Lens 8 VDC Power Consumption Receiver 5vAmaximum Fuse Lens Aux 1 5A Video Input Output 75 ohms Video Bandwidth 10 MHz Video Gain Unity Video Formats NTSC or PAL Control Method Standard or extended Coaxitron Auxiliary Outputs One open collector TTL One N O N C Form C relay MECHANICAL Video Connectors BNC P T Camera Auxiliary Lens Power Connectors Screw terminals GENERAL Environment Indoor Construction Aluminum Finish Black polyester powder coat Operating Temperature 10 to 122 F 23 to 50 C Dimensions 10 3 L x 6 0 W x 1 75 H inches 26 2 x 15 2 x 4 4 cm Weight 1 25 Ib 0 58 kg CERTIFICATIONS RATINGS CE Class A UL cUL pending NEMA 1 IP 10 pending Design and product specifications subject to change without notice Pelco Manual C1506M 3 00 11 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Three years on Genex Series multiplexers server and keyboard Two years on cameras and all st
9. ks of Pelco Copyright 2000 Pelco Esprit and Camclosure are trademarks of Pelco All rights reserved
10. ler with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a writ ten explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair Goods returned for repair or credit should be clearly identified with the assigned CA RA number and freight should be prepaid All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Ship freight prepaid to Pelco 300 West Pontiac Way Clovis CA 93612 5699 REVISION HISTORY Manual Date Comments C1506M 3 00 Original version Pelco the Pelco logo Spectra Genex Legacy and PelcoVision are registered trademar
11. may bear the following marks unit RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol indicates that there are important oper ating and maintenance instructions in the literature This symbol indicates that dangerous voltage consti tuting a risk of electric shock is present within this CAUTION N accompanying this unit Please thoroughly familiarize yourself with the information in this manual prior to installation and operation 2 Pelco Manual C1506M 3 00 DESCRIPTION The IRD ERD2000 Series Receiver operates Pelco s fixed speed pan tilts and domes The receiver works with standard and extended Coaxitron controllers including the CM6700 7500 8500 9500 KBD9000 MPT9000 9008 9500 and MX4000 With Coaxitron control pan tilt and lens control sig nals are transmitted over the video coaxial cable The control data is superimposed on the vertical blank ing interval of the video signal Standard features include pan tilt control including auto and random scan camera power lens control zoom iris and focus and two auxiliary outputs The receiver also can be used with the LRD41TLC Test Local Control module which allows on site testing and troubleshooting of system functions The TLC module plugs into the receiver and operates off the receiver s power Models IRD2024 Indoor fixed speed Coaxitron receiver 24 VAC input 24 VAC output for camera power and panltilt operation ERD2200 Outdoor fixed speed Coaxitr
12. nstalled 35 feet 10 m would require a minimum wire gauge of 20 AWG Table B Video Coaxial Wiring Distances Cable Type Maximum Distance RG59 U RG6 U RG11 U 750 ft 229 m 1 000 ft 305 m 1 500 ft 457 m Minimum cable requirements 75 ohms impedance All copper center conductor All copper braided shield with 95 braid coverage or less from the 24 VAC source Pelco Manual C1506M 3 00 9 SPECIFICATIONS ERD2200 ELECTRICAL Input Voltage 115 230 VAC 50 60 Hz Output Voltage Camera 24 VAC or 115 230 VAC if using enclosure power Lens 8 VDC Pan Tilt 24 115 230 VAC Enclosure 115 230 VAC Power Consumption Receiver 5vAmaximum Pan Tilt and Camera 48 vA maximum at 24 VAC includes 5 vA maximum for camera Fuses Main 115 VAC 5A 230 VAC 25A Enclosure 115VAC 4A 230 VAC 2A Lens Aux 1 5A Video Input Output 75 ohms Video Bandwidth 10 MHz Video Gain Unity Video Formats NTSC or PAL Control Method Standard or extended Coaxitron Auxiliary Outputs One open collector TTL One N O N C Form C relay MECHANICAL Video Connectors BNC P T Camera Auxiliary Lens Power Connectors Screw terminals Cable Entry Openings for 75 inch 1 91 cm conduit GENERAL Environment Outdoor Construction Aluminum receiver steel housing Finish Gray polyester powder coat Operating Temperature 50 to 122 F 46 to 50 C Dimensions 15 2 L x 12 2 W x 5 0 H in
13. on receiver 115 230 VAC input 24 VAC output for cam era power 24 115 or 230 VAC output for pan tilt operation and 115 or 230 VAC out put for enclosure accessories MOUNTING Attach the IRD2024 to a flat surface Attach the ERD2200 to a vertical surface with the conduit entries facing down Use the housing as a tem plate for drilling mounting holes Use 1 4 inch fasteners not supplied of the appropriate length Refer to the illustrations below ANCHOR OR TOGGLE BOLT WOOD SCREW ANCHOR NOT SUPPLIED NOT SUPPLIED NOT SUPPL m uum aa WALLBOARD WALL CONCRETE WALL Pelco Manual C1506M 3 00 3 ERD2200 WIRING Input Power Enclosure Main ERD2200 Power Connections 115 VAC 4A 5A 230 VAC 2A 25A nu G Ti ENCLOSURE FUSE 1 Fuses are installed for 115 VAC operation n For 230 VAC operation install the appropriate POWER fuses supplied een pp 115V Tazo 2 Set the power selector switch to either 115V or 230V to match your input power POWER GROUND SELECTOR fFe path STUD SWITCH L N OL N Q 3 Connect main power The bottom of the housing has five conduit entries fittings not supplied to bring wiring into the re ceiver Connect 115 230 VAC to the Main Power In terminals inside the receiver with AC high going to the L line terminal and AC low to the N neutral terminal Connec
14. t ground wire to the stud in side the housing Do not turn on power 4 Connect enclosure power optional If you have an enclosure with heater blower or defroster connect wires from the pan tilt or enclosure to the Enclosure Power Out terminals inside the receiver The enclosure must use the same power as the receiver 5 Set the P T SELECT switch on the rear of the receiver according to the pan tilt voltage requirements PAN TILT VOLTAGE WARNING Never move the P T SELECT switch toward the high voltage side unless you are positive your pan tilt requires 115 230 VAC Inadvertently selecting the switch for high voltage will permanently damage a 24 VAC panltilt If you select 24 VAC the maximum output is 48 vA supplied by the transformer inside the receiver make sure the combined output of your pan tilt and camera if it also uses 24 VAC does not exceed this output 4 Pelco Manual C1506M 3 00 Rear View of Receiver 115 230 iid J0 i m be fe fe ERD OPTION 24 V INPUT PI SELEG Front View of Receiver PWR cx 7 VIDEO 7 IN OUT
15. the auxiliary outputs optional AUX 1 is a 5 VDC 20 mA maximum open collector output Use the auxiliary To operate low current relays To turn on or off a Pelco window wiper that has TTL circuitry AUX 2 is a normally open normally closed Form C relay Relay contacts are rated at 1A at 24 VDC or 5A at 115 VAC 8 Double check all wiring connections and then turn on power 6 Pelco Manual C1506M 3 00 OPERATION When power is applied to the receiver the green PWR LED on the receiver lights Whenever the receiver gets a valid Coaxitron control signal the green CX LED blinks Random Auto Scanning Operation of random and auto scanning depends on whether your transmitter controller is communicating with the IRD2000 ERD2200 in standard or extended Coaxitron mode Standard Coaxitron Press the Pan Auto or Autoscan key to begin random scanning In random scan operation the pan tilt travels between the limit stops with a random scan period of 0 60 seconds The pan tilt then stops for a random period of 0 60 seconds before starting another random scan period The direction the pan tilt moves when another scan period is started is also randomly determined When a pan limit stop is reached scan direction reverses automatically Press the Pan Auto or Autoscan key again to start auto scanning After approximately a half hour of auto scanning the pan tilt switches to random scanning To turn off random auto scanning press the