Home

Pelco Switch ICI3008 User's Manual

image

Contents

1. 1 0 WARNINGS Priortoinstallation and use ofthis product the following WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes Only use replacement parts recommended by PELCO 2 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry NOTE Familiarize yourself with the infor mation in this manual prior to installation and operation Contact the customer s dealer in staller prior to installation and operation Some warranties and or service agreements may be affected PELCO 1 13016 1 13008 16 8 Position Inter Check Switchers Installation and Operation Manual C1007M B 2 96 2 0 SCOPE This manual covers the installation and operation of the Inter Check ICI3008 and ICI3016 switchers 2 1 DESCRIPTION The Inter Check ICI3008 and ICI3016 are alarming se quential video switchers designed to be used exclusively with the Inter Check ICI3000P Point of Sale POS moni toring systems Pelco 3500 Pelco Way Clovis CA 93612 5699 559 292 1981 800 289 9100 FAX 800 289 9150 or 559 292 3827 3 0 INSTALLATION Connect the 9 pin interface cable supplied with the ICI3008 IC13016 switcher into the port labeled RS 232 of the ICI3000P refer to Fig 1
2. Bank Address Loop Select Baud Rate Select NC NC NOTE Cover must be removed to access this dip switch Loop CAMERAS 16 31 Address 0001 VIDEO OUT 16 15 e VI DEO I NPUTS Loop 1 CAMERAS 1 15 Address 15 14 VI DEO I NPUTS TO MONI TOR OR VCR Shadow switchers are available in either 8 or 16 positions Figure 2 Cascading the ICI30008 or ICI3016 6 Pelco Manual C1007M B 2 96 Notes Pelco Manual C1007M B 2 96 7 0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners includ ing when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper exclu
3. Connect the modular phone plug of the interface cable into the port labeled DATA IN on the ICI3008 ICI3016 switcher refer to Fig 1 Connect the video inputs from your cameras to the BNC s labeled VIDEO INPUTS on the ICI3000P Connect a coaxial cable between the port labeled VIDEO OUT of the ICI3008 ICI3016 and the port labeled VIDEO IN 1 of the ICI3000P If multiple ICI3008 ICI3016 switchers are being cascaded 1 linked to create a larger switcher con nect a coaxial cable from the last video input of the first Inter Check switcher to the port labeled VIDEO OUT of the second Inter Check switcher Remove the cover of the second Inter Check switcher and set the 8 position dip switch to 0001 0000 Remove the cover of the first Inter Check switcher and set the 8 position dip switch to 0000 1000 refer to Fig 2 Connect the desired alarm outputs to any peripheral equipment requiring a normally open contact using the alarm interface connector supplied Pin one cor responds to camera one pin two with camera two etc The separate wire from the Inter Check switcher is ground See Section 6 0 for alarm pin out con figuration information Power up the Inter Check units using the transform ers supplied with each unit To verify communication between the Inter Check switcher and the ICI3000P press F9 Press F9 again Next select camera one by entering a 1 one followed by the EN
4. for this camera in seconds or zero 0 to bypass then press ENTER 5 Repeat these steps until all selected registers have a camera number and dwell time assigned to them This list will hold 32 thirty two line items 4 2 EDITING AN EXISTING REGISTER LIST To edit a camera list press ENTER Press ESC until the desired line is displayed Enter the appropriate data as described above Press ESCAPE until you reach the next line you wish to edit or the end of the list Press ENTER to return to the SYSTEM MENU The Inter Check unit will display the previously pro grammed values when you re edit the Shadow List For instance if you wanted to change the dwell time of a camera from 15 seconds to 10 seconds the following in formation would be displayed REG CAM DWL 8 6 15 10 NOTE Previously programmed values will be deleted when you exit the shadow list 5 0 OPERATION 5 1 CAMERA SEQUENCING While in the monitoring mode the Inter Check switcher will sequence through the camera presets according to the programmed dwell time assigned to each camera To stop camera sequencing simply press the S button on your keyboard To resume switching press the S key again 5 2 MANUAL REGISTER MONITORING While in the monitoring mode press F1 To display the transaction data on the LEFT side of the monitor press 1 one To display the transaction data on the RIGHT side of the monitor press 2 two Enter
5. od Alarm Out Dataln Power 7 Figure 1 Data Cable Connection Between ICI3000P and ICI3008 Pelco Manual C1007M B 2 96 3 Following is an explanation of the prompts REG This is the electronic cash register ECR number If using an ICI3000P an ECR s number is determined by the address assigned to it on the ICI1000PIM installed at the register CAM This is the camera number you wish to assign to an ECR The camera number is determined by its video input on the ICI3008 ICI3016 switcher When cascading 8 or 16 position Inter Check switchers camera 8 or 16 will be the first video input of the second switcher refer to Fig 1 Each camera input has a corresponding alarm output assigned to it on the ICI3008 ICI3016 switchers These alarm outputs may be used in conjunction with the video inputs to trigger peripheral devices They may also be used without video inputs to trigger pan tilt presets on PELCO matrix switchers DWL The Dwell determines how long a selected camera will remain on the monitor in seconds be fore switching to the next video camera Entering zero 0 for this value will cause the switcher to by pass the camera 1 Toeditthis menu press ENTER or press ESC to return to the SYSTEM MENU 2 Enter the register number you wish to select then press ENTER 3 Enter the camera number or alarm output you would like assigned to this register followed by ENTER 4 Select the dwell time
6. the register number to be monitored then press ENTER Pelco Manual C1007M B 2 96 6 0 ALARM OUTPUTS Both the ICI3008 and ICI3016 shadow switchers pro vide alarm outputs for alarming other peripheral equip ment The ICI3008 provides eight 8 alarm outputs and the ICI3016 provides sixteen 16 alarm outputs A particular alarm output is enabled according to the camera selected 6 0 ALARM PIN OUT CONFIGURATION 25 PIN CONNECTOR FOR ICI3016 13 1 Q OQ OO OO O QOO 14 Alarm Output Alarm Output 1 Alarm Output 2 Alarm Output 3 Alarm Output 4 Alarm Output 5 Alarm Output 6 Alarm Output 7 Alarm Output 8 Alarm Output 9 Alarm Output 10 Alarm Output 11 Alarm Output 12 Alarm Output 13 Alarm Output 14 Alarm Output 15 Alarm Output 16 Common Ground Pelco Manual C1007M B 2 96 For example when camera 4 is selected alarm output 4 will be enabled The output for both switchers is nor mally open The following diagrams list the pin assignments for both switchers Use this information in wiring external alarmable equipment 9 PIN CONNECTOR FOR ICI3008 y 5 3k Alarm Output Alarm Output 5 Alarm Output 7 Alarm Output 6 Alarm Output 8 Alarm Output 1 Alarm Output 3 Alarm Output 2 Alarm Output 4 Common Ground 1 2 3 4 5 6 7 8 9 1 2 3 4 5161718 DIP SWI TCH DESCRI PTI ON Switch Function 1 Bank Address Bank Address Bank Address
7. Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 PELLO PELCO 3500 Pelco Way Clovis CA 93612 5699 USA 559 292 1981 800 289 9100 FAX 800 289 9150 or 559 292 3827 International customers call 1 559 292 1981 or FAX 1 559 348 1120 Product specifications subject to change without notice C1007M B Pelco Manual C1007M B 2 96
8. TER key The first red light labeled 1 on the first switcher should be on Re peat this step for each camera input on each switcher If an 8 or 16 position switcher has a second switcher cascaded from it selecting camera 8 or 16 respec tively will cause the first light of the second switcher to be activated 4 0 PROGRAMMING NOTE For a complete explanation of pro gramming features refer to the programming section of the operation manual supplied with the ICI3000P 4 1 REGISTER CAMERA ALARM DWELL ASSIGNMENTS To enter the programming mode press ENTER The following menu will be displayed SELECT MENU Register 1 or 2 Operator 1 or 2 Exceptions on off Camera Select Screen print on off Auto camera search on off Reverse video on off System Program Exceptions Program Syssave sysread hot key list Press 8 SYSTEM and the following menu will be displayed SYSTEM MENU Chars line Lines for small scrn 1 or 2 Small scrn position 1 or 2 Large scrn position 1 or 2 Alarm dwell time Channel parms Printer parms Set clock Ext cam select Shadow list OON NUN Press 0 SHADOW LIST and the following prompt will be displayed Shadow List REG CAM DWL 1 ESC to exit or CR to edit Pelco Manual C1007M B 2 96 RS 232 Alarm Datain Video Videoln Power Ce aan
9. ding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications thatis preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have ad
10. ditional rights which are subjectto variation from state to state Ifawarranty repairis required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Copyright 1996 Pelco All rights reserved RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska

Download Pdf Manuals

image

Related Search

Related Contents

Marley Fluid Cooler Fan and Pump Control Panel System User  取 扱 説 明 書  Dynacord PowerH Series User's Manual  balanceadora coats 850 en esp  One For All WM 4450 flat panel wall mount  VPCL13 Series  MANUALE D`USO E MANUTENZIONE pagina 6 USE AND  Camosun College Audio Effects Processor    TEW-455APBO Quick Installation Guide  