1. CM9750 REL Series Relay Interface Installation Operation Manual C534M 2 98 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA e www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 CONTENTS Section 1 0 2 0 3 0 GENERAL iii aaa 1 1 IMPORTANT SAFEGUARDS AND WARNINGS INSTALLATION iiias nasisisi issii 3 1 MOUNTING INSTRUCTIONS 3 2 CONNECTING TO THE CONTROLLER 3 3 CONNECTING POWER ss ociosa rica 3 4 WIRING THE RELAY OUTPUTS isisisi 3 5 INSTALLING AND REMOVING THE RELAY CARDS 3 6 CHANGING THE JUMPER LOCATIONS Relay Card Location 40 OPERATION cosa ita e 9 50 MAINTENANG Bia usara aia 10 511 REPLACING THE FUSE oia tati 10 6 0 WARRANTY AND RETURN INFORMATION e 12 LIST OF ILLUSTRATIONS Figure Page 1 Front and Rear Views of the CM9750 CM9760 Relay Interface Unit 4 2 Relay Output Functional Schematic i 5 3 Wiring External Equipment to the Relay Outputs sa 4 5 Relay Card Jumper Locations i 8 LIST OF TABLES Table A B Page 50 DIn CONMECION urna 6 Relay Jumper Reference Chart 8 REVISION HISTORY Manual Date Comments C534M 2 98 Original version Pelco Manual C534M 2 98 1 0 GENERAL 1 1 IMPORTANT SAFEGUARDS AND WARNINGS
2. of internal jumpers The unit is shipped with the contacts in the normally open position Each Relay Interface unit provides outputs for four GPIs each GPI controls 8 relays Refer to Figure 1 for the front and rear view of the unit 2 1 MODELS CM9750 REL16 Provides 16 relay outputs Includes transformer to convert 120 VAC to 24 VDC CM9750 REL16 X Same as CM9750 REL16 except has 230 VAC transformer System 9750 Relay Interface POWER INPUT RELAYS 11 20 RELAYS 1 10 RELAYS 21 32 E 9 E Figure 1 RELAY 32 INPUT FROM RELAY 1 Dn CM9750 CM9760 TYPICAL FOR ALL RELAY OUTPUTS Front and Rear Views of the CM9750 CM9760 Relay Interface Unit Pelco Manual C534M 2 98 2 2 CIRCUIT DESCRIPTION The Relay Interface consists of two relay cards with additional room for two more one motherboard and one power supply board The unit receives TTL level signals from the GPI SPINC card located in the CM9750 CM9760 Controller through the 50 pin connector on the rear panel of the unit This TTL signal is then inverted and applied to the corresponding relay to close the contact The position of the strap determines the condition of the output Refer to Figure 2 JUMPER RELAY OUTPUT TYPICAL FOR ALL RELAY CIRCUITS 12 VDC TTL IN I I I I RELAY MAX DC CURRENT 1 AMP Figure 2 Relay Output Functional Schematic Pelco Manual
3. C534M 2 98 5 3 0 INSTALLATION 3 1 MOUNTING INSTRUCTIONS NOTE The Relay Interface unit can be configured to provide either nor mally open or normally closed relay outputs The unit is shipped with all outputs in the normally open mode of operation Ifyou need to configure outputs for normally closed opera tion refer to Sections 3 5 and 3 6 prior to mounting the unit The Relay Interface mounts in a 19 inch 48 26 cm rack using standard mounting hardware The unit occupies 1 rack unit 1 75 in or 4 45 cm of vertical space The unit operates on TTL signals from the Controller Because of distance limitations the unit must be mounted in the same rack as the Controller for proper operation 3 2 CONNECTING TO THE CONTROLLER The unit comes equipped with a pretested 3 foot 0 91m ribbon cable to connect to the SPINC card located in the Controller Prior to connecting the equipment refer to the Controller Manual for installation information To connect the two pieces of equipment connect the supplied cable to the 50 pin connectors located on the Relay Interface and the Controller Refer to Table A for the connector pin assignments 3 3 CONNECTING POWER GPI 1 8 GPI 1 6 GPI 1 4 GPI 1 2 NC GPI 2 8 GPI 2 6 GPI 2 4 GPI 2 2 NC GPI 3 8 GPI 3 6 GPI 3 4 GPI 3 2 NC GPI 4 8 GPI 4 6 GPI 4 4 GPI 4 2 GND The unit comes equipped with a 120 VAC or 230 VAC to 24 VDC wall moun
4. Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes 2 Only use replacement parts recommended by Pelco 3 After replacement repair of this unit s electrical components conduct a resis tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Please thoroughly familiarize yourself with the information in this manual prior to installation and operation Pelco Manual C534M 2 98 3 2 0 DESCRIPTION J The Relay Interface units of the CM9750 REL Series provide up to 32 relay con tacts for operating external equipment such as VCRs and lights The unit is shipped from the factory equipped with 16 outputs Each of the relays can be configured for normally open or normally closed operation by the placement
5. anel of the unit To replace the fuse first remove power to the unit by discon fuse of the same rating Fail necting the power at the wall socket Rotate the fuse holder counterclockwise until ure to do so could result in the fuse holder comes out of its receptacle Replace the fuse serious damage to the unit 10 Pelco Manual C534M 2 98 NOTES Pelco Manual C534M 2 98 11 6 0 WARRANTY AND RETURN INFORMATION Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Copyright 1998 Pelco All rights reserved 12 WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard e Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products e Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous
6. e warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state Ifa warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are l
7. ing External Equipment to the Relay Outputs BOARD A OUTPUTS 1 8 BOARD C OUTPUTS 17 24 POWER SUPPLY BOARD BOARD B OUTPUTS 9 16 BOARD D OUTPUTS 25 32 Figure 4 Relay Card Location Pelco Manual C534M 2 98 7 Table B Relay Jumper Reference Chart 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 OMANOAARWNDY LISTPONZOISCLEONE 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 Ne o Rae oA aa En a fl fr Ei Ei 1 2 N O 2 3 N C PIN 1 PIN 2 PIN 3 TYPICAL FOR JUMPERS ONE THROUGH FOUR NOTE All straps are shown in the Normally Open Position Figure 5 Relay Card Jumper Locations BHRHHHAHPHAPHPWWWWWWWW SISGEGRIESISTEGSHS 1 2 N O 2 3 N C PIN 3 PIN 2 PIN 1 TYPICAL FOR JUMPERS FIVE THROUGH EIGHT Pelco Manual C534M 2 98 4 0 OPERATION Pelco Manual C534M 2 98 There are no specific operating instructions for the unit The unit begins operation once power is applied All operating commands are issued from the appropriate CM9750 CM9760 Keyboard s as defined in the Setup File For additional informa tion on the operation of the Relay Interface unit GPI relays refer to the Operation Manual or to the System Administrator Manual 5 0 MAINTENANCE 5 1 REPLACING THE FUSE WARNING Always re The unit is equipped with a 2A fuse on the input The fuse holder is located on the place a blown fuse with a rear p
8. motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Sixmonths on all pan andtilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The abov
9. ocated outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Pelco Manual C534M 2 98
10. t trans former Plug the transformer into an appropriate location and connect the other end to input connector on the rear of the unit The unit is operational once power is applied to the unit Table A 50 Pin Connector NWOBUODNWO Pelco Manual C534M 2 98 3 4 WIRING THE RELAY OUTPUTS Refer to Figure 3 Select the desired relay output and insert the wires to be used into the square holes in the terminal Tighten the screws until the wires are properly secured 3 5 INSTALLING AND REMOVING THE RELAY CARDS To install or remove any of the relay cards remove the top cover to the unit Refer to Figure 4 for the identification of each board To remove a specific board remove the mounting hardware four Phillips screws and disconnect the two ribbon cables connecting the relay card to the mother board The card can now be removed from the unit 3 6 CHANGING THE JUMPER LOCATIONS NOTE ach board is the same and Remove the desired board s as described Section 3 5 therefore has the same silkscreen identification for the relays and jump Next determine which output you wish to change Once decided refer to Table B ers for the corresponding board and jumper Once the proper board has been determined gain access to the desired jumper and place in the desired setting Refer to Figure 5 for the jumper pin assignments INSERT CONNECTIONS RELAY 32 FROM EXTERNAL EQUIPMENT a TYPICAL FOR ALL RELAY OUTPUTS Figure 3 Wir
Download Pdf Manuals
Related Search
Related Contents
Guide de l`éleveur - Chambre d`Agriculture des Landes Fujioh BUF-06E User's Manual 取扱説明書 [PDF形式] Here - FreeTrack Samsung WB5000 دليل المستخدم DM - 14 settembre 2005 - Regione Calabria Manual do Usuário UltraView UVC-6130-1 WDR Box Camera User Manual Entrepreneur de petites entreprises option développeur d`activités Copyright © All rights reserved.