1. PELCO MR5000L Ceiling Monitor Mount for the MR5000 Series Public Viewing System Installation Operation Manual cus LISTED C221M C 6 03 Pelco World Headquarters 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 IMPORTANT SAFEGUARDS AND WARNINGS 1 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water oak oD Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat N Only use attachments accessories specified by the manufacturer 8 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 9 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as when the power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture the apparatus does not operate normally or the apparatus has been dropped 10 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vase
2. ICS DO101ABK Figure 1 MR5000L Mount Arm Table A Video Coaxial Cable Requirements RGS59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Minimum cable requirements 75 ohms impedance All copper center conductor All copper braided shield with 95 braid coverage Pelco Manual C221M C 6 03 NOTE 7he bottom set screw on the swivel collar is for positioning the mount arm Refer to Figure 1 Finish the instalation before adjusting the position of the system Pelco Manual C221M C 6 03 Install Mount Arm a Install the MRWA wall mount not supplied or MRCA ceiling mount not supplied For installation surfaces and minimal hardware requirements refer to page 2 of this manual Apply anti seize to the threads of the 1 1 2 inch NPT pipe provided Thread the swivel collar at the top of the mount arm onto the pipe Tighten the top set screw on the swivel collar refer to Figure 1 to secure the mount to the NPT pipe Assemble Monitor Rack The monitor used will dictate the position of the rack sides refer to Figure 2 Position and attach the rack sides to the mount base CONFIGURATION FOR THE PMCS19A Figure 2 Monitor Rack Assembly Position and Attach Monitor Rack to Mount Arm a Place the monitor rack onto the bottom of the mount arm Refer to Figure 3 and do the following to properly position the rack on the mount arm PMCS19A Use the bolt hole position PMC21A Us
3. 00 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the neglige
4. E NOTE THE POSITION OF THE FRONT FEET AND BACK FEET MOUNT HOLES WILL VARY WITH MONITOR MODEL 01121 Figure 7 Install Monitor Connect Video and Power to Monitor a Connect the video cable to the BNC video input on the rear panel of the monitor b Plug the power cable into the AC INLET connection on the rear panel of the monitor Refer to the manual supplied with the monitor for operating instructions CAUTION Final Adjustments Secure the monitor to the rack before a Monitor Rack Refer to Figure 7 and adjust the monitor angle The rack is adjustable adjusting the angle of the in 5 degree increments up to a 15 degree angle rack b Mount Arm Turn mount arm to desired position Tighten the bottom set screw on the swivel collar to secure in place WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Ex ceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 CC3700 and MC3500 MC3600 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard and 090 Series Camclosure Camera System Two years on 100 150 200 and 300 Series Camclosure Camera Systems Two years on all standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM6800E CM8500 CM95
5. dware to attach feet PMC27A Two 8 x 50 inch Phillips pan head screws and fin ishing washers supoled see page 4 PMCS19A Two M4 x 12 mm Phillips pan head screws and fin ishing washers supoled see page 4 Do not use any other type of hardware to attach the back feet to the monitor CAUTION Secure the mount tack before install ing the monitor Pelco Manual C221M C 6 03 Q Prepare Monitor for Installation Refer to Figure 6 and remove the monitor s back feet and side screws Figure 6 Prepare Monitor Install Monitor a Verify that the monitor rack is level Place the monitor onto the monitor rack For proper installation the front feet of the monitor should be in the holes in the front of the rack Refer to Figure 7 b Use the following hardware to secure the back of the monitor to the rack PMCS19A Two M4 x 12 mm black Phillips pan head screws provided PMC21A Two 8 x 50 inch black Phillips pan head screws provided c Adjust the sides of the rack to fit against the sides of the monitor Use the following hardware to secure the monitor to the rack sides PMCS19A Use the two M6 x 12 mm Phillips pan head screws and washers provided PMC21A Four 8 x 50 inch black Phillips pan head screws provided t SECURE BOTH SIDES OF MONITOR WITH HARDWARE FRONT FEET OF MONITOR MONITOR RACK ANGLE ADJUSTMENT SECURE BOTH SIDES OF MONITOR WITH HARDWAR
6. e the bolt hole position Use the 3 16 inch Allen wrench to secure the front of the monitor rack to the mount arm with two 5 16 18 x 75 inch Allen head bolts and locking washers Secure the back of the monitor rack with two 10 32 x 375 inch black Phillips pan head screws and locking washers Figure 3 Attach Rack to Mount Arm Install MR5000 Series Accessories PCM5000 Light Duty Camera Mount Assembly a b The PCM5000 camera mount assembly can be installed on the top or bottom of the MR5000M mount arm To install the camera assembly onto the MR5000 Series mount refer to Figure 4 and do the following 1 Pull video and electrical wire COLLAR SET cable for the camera out SCREWS through the end of the mount arm Make all camera video and electrical connections 2 Place the end of the camera assembly into the end of the MR5000 Series monitor mount arm Tighten the set screws to secure the camera assembly MOUNT ARM SET SCREW 01124 Refer to the manuals supplied with Figure 4 PCM5000 Installation the camera and the PCM5000 for detailed installation and operation instructions ICS DO101ABK Camclosure Integrated Camera System a b C Refer to Figure 5 and do the following to attach the adapter plate of the ICS DO101ABK to the base of the ICS DO101ABK 1 Align the adapter plate to the base of the ICS DO101ABK 2 Use the two 10 32x 375 inch pan head screws and internal lock wash
7. ers to attach the base of the ICS DO101ABK to the adapter plate Prepare the video and electrical cabling for the ICS DO101ABK 1 Feed the 42 inch video cable provided through the monitor feedthrough hole in the mount arm and out the end of the mount arm 2 Pull power wires through the ICS DO101ABK feedthrough refer to Figure 1 located at the bottom of the mount arm Remove the 50 inch plug if it is installed 3 Pull wires through the adapter plate of the ICS DO101ABK and into the base of the ICS DO101ABK 4 Use the supplied 3 16 inch Allen wrench to slightly loosen do not remove the two 5 16 18 x 75 inch Allen pan head screws that secure the MR5000M mount base to the mount arm 5 Feed the video cable 0A S attached to the ICS DO101ABK back box through the ICS DO101ABK feedthrough in the mount arm 6 Hook the adapter plate over the loosened screws refer to Figure 5 Tighten the screws to secure the adapter plate to the mount ADAPTER PLATE CAMCLOSURE BASE Refer to the manual supplied with the ICS DO1 01ABK for NOTE POSITION THE BASE SO THAT THE CONDUIT COVER detailed installation and IS TURNED TOWARDS THE BACK OF THE MOUNT operation instructions Gigs Figure 5 ICS DO101ABK Installation Pelco Manual C221M C 6 03 NOTE Aeattach the back feet to the monitor if it Is used in an installation other than described in this manual Only use the follow ing har
8. he MR5000L can support loads up to 66 pounds 29 94 kg INSTALLATION CAUTION A N Refer to local electrical codes before installing these units Local codes dictate how to prepare wiring for all equip ment Refer to Table A for video coaxial cable distances The following parts are supplied 1 Mount arm 1 Rack base 2 Rack sides 1 1 1 2 inch NPT pipe 6 8x 50 inch Phillips pan head screws and finishing washers use for PMC21A sides and feet 2 M4x 12mm Phillips pan head screws and washers use for PMCS19A feet 2 M6x 12mm Phillips pan head screws and washers use for PMCS19A sides 2 10 32 x 375 inch Phillips pan head screws and lock washers 2 5 16 18 x 75 inch hex bolts and lock washers 2 End caps for top and bottom of mount arm 1 50 inch hole plug 1 3 16 inch Allen wrench 1 3 82 inch Allen wrench for set screws 1 4 cc tube of anti seize Prepare Video and Electrical Cabling The MR5000L monitor mount is capable of providing a concealed wire SWIVEL COLLAR FEEDTHROUGH TOP SET SCREW installation To conceal cables pull BOTTOM SET cables through the feedthrough holes SCREW of the mount arm Refer to Figure 1 TOP END for feedthrough hole locations To CAP feed cables through the top of the FEEDTHROUGH swivel collar temporarily remove the HOLE top end cap from the mount arm if installed to assist in directing cables FEEDTHROUGH HOLE FEEDTHROUGH FOR
9. lovis CA 93612 5699 f you are located outside the continental U S Alaska Hawaii or Puerto Rico Intermediate Consignee Ultimate Consignee American Overseas Air Freight Pelco 320 Beach Road 3500 Pelco Way Burlingame CA 94010 Clovis CA 93612 5699 USA USA REVISION HISTORY Manual Date C221M 9 01 C221M A 9 02 C221M B 2 03 C221M C 6 03 Comments Original version Revised nportant Safeguards and Warnings and added an installation warning Supplied hardware revised Added ETL Listing and revised Safeguards and Warnings Pelco the Pelco logo Spectra Genex Esprit Camclosure and Legacy are registered trademarks of Pelco Copyright 2003 Pelco All rights reserved 8 Pelco Manual C221M C 6 03
10. nce of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization num ber CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RAnumber and freight should be prepaid Ship to the appropriate address below f you are located within the continental U S Alaska Hawaii or Puerto Rico Service Department Pelco 3500 Pelco Way C
11. nt operating and maintenance instructions in the literature accompanying this unit Please thoroughly familiarize yourself with the information in this manual prior to installation and operation Pelco Manual C221M C 6 03 IMPORTANT Refer to the following chart for recommended mounts installation surfaces and minimal hardware requirements Mount Recommended Mounting Surface Recommended Hardware MRCA Solid Concrete Four 5 16 x 2 3 4 inch strike anchors Ceiling Wall board 2 x 4 s Two 5 16 x 2 inch lag bolts bolts must Mount be attached to stud Plywood 3 4 inch construction grade Four 5 16 x 2 inch lag bolts MRWA Solid Concrete Three 5 16 x 2 3 4 inch strike anchors ae Hollow cinder block Three 5 16 x 2 1 2 inch T anchors Wall board 2 x 4 s Three 5 16 x 2 inch lag bolts bolts must be attached to stud Plywood 3 4 inch construction grade Four 5 16 x 2 inch lag bolts Recommended strength of concrete is 3600 psi or 25 Mpa DESCRIPTION Pelco Manual C221M C 6 03 Pelco s MR5000 public viewing system is specifically designed for retail applications to provide a clear visual warning to potential shoplifters that these premises are under surveillance When properly installed the system is an effective deterrent against shoplifting Use the MR5000L to mount Pelco s PMCS19A and PMC21A monitors and other view station accessories PCM5000 and ICS DO101ABkK to a ceiling T
12. s shall be placed on the apparatus 11 Warning To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 12 To reduce the risk of shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so 13 Unless the unit meets NEMA Type 3 3R 3S 4 4X 6 or 6P standards it is designed for indoor use only and must not be installed where exposed to rain and moisture 14 Only use parts recommended by Pelco 15 Use only installation methods and materials capable of supporting four times the maximum specified load 16 Installation and servicing should be done only by qualified service personnel and conform to all local codes 17 The MR5000L is to be secured to approved ceiling surfaces using the MRCA mount as stated in this manual in order to maintain its UL Listing and ETL Listing 18 The MR5000L is to be secured to approved wall surfaces using the MRWA mount as stated in this manual in order to maintain its UL Listing and ETL Listing 19 UL Listed when used with the PMC14F and PMC21A monitors 20 ETL Listed when used with PMCS14A PMCS17A and PMCS19A monitors The product and or manual may bear the following marks This symbol indicates that dangerous A N voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK This symbol indicates that there are DO NOT OPEN AN importa