1. Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment Sa REVISION HISTORY Manual Date Comments C493 5 90 Original manual C493 1 91 Rev A Revised to include HB1524 and HS1500H options and heater blower kit information C493 5 91 Rev B Figure 2 HS1500H Installation added C493 1 93 Rev C Exploded assembly diagram and parts list updated C493M D 9 95 Rev D Revised to include wiring instructions for tamper switch and metric equivalents for specifications Heater blower wiring diagram updated to include 24 VAC model C493M E 1 95 Rev E Revised to include updated tamper switch bracket part numbers and exploded view diagram
2. 10A maximum switching c urrent 125V maximum switching voltage Formed 10 gauge 0 134 0 Polyester powder coat See Figure 6 Indoor 32 to 120 0 to 4 15 lbs 4 oz 6 77 kg 34 cm steel 8 89 C Design and product specifications subject to change without notice C493M G 11 97 13 13 33 35 6 50 16 51 12 25 31 12 5 75 14 61 10 00 25 40 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 6 HS1500 Enclosure Dimension Drawing C493M G 11 97 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series ixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper exclu
3. Installation and servicing should only be done by qualified service personnel and conform to all local codes 2 Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 3 Only use replacement parts recommended by Pelco 4 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry 5 The installation method and materials should be capable of supporting four times the weight of the enclosure pan tilt camera and lens combination 6 The camera and lens combination shall not exceed 20 Ibs 9 09 kg The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol indicates that there are important operating and maintenance instructions AN in the literature accompanying this unit CAUTION To reduce the risk of electrical shock do not remove cover No user servicable parts inside Refer servicing to qualified service personnel Please thoroughly familiarize yourself with the information in this manual prior to installation and operation 4 C493M G 11 97 Description The HS1500 is a hig
4. to install a replacement switch refer to Figure 4 for the correct position of the bracket switch and perform the following steps 1 Remove the front cover 2 Install the bracket switch and secure with lockwashers and nuts TAMPER SWITCH WIRING The tamper switch comes with both a Normally Open and a Normally Closed contact For a Normally Open circuit use the open and common terminals for a Normally Closed circuit use the closed and common terminals BRACKET SWITCH MOUNTING PLATE Figure 4 Tamper Switch Installation Maintenance Maintenance performed at regularly scheduled intervals will help prolong the operational life and appearance of the equipment Clean the Lexan window with a mild non abrasive detergent in water and a soft cloth regularly to help maintain picture clarity For a heavily soiled window use vinyl cleaner C493M G 11 97 Exploded Assembly Diagram Figure 5 HS1500 Enclosure Exploded Assembly Diagram Table A HS1500 Enclosure Exploded Assembly Parts Lists Item No Oty Description Part Number 1 Bracket switch break in HS10004313COMP 2 Window 10 x 9 x 50 drilled MR5 clear Lexan HS150010009 3 Plate mounting HS15004001 COMP 4 Cover front HS15004003COMP 5 Tilt table HS15004008COMP 6 Cover top corner mount HS15004023COMP 7 Bracket mount tilt table left HS20004115COMP 8 Bracket mount tilt table ri
5. 7 ft 642 m HB1524 24 VAC 85 Watts 20 Awg 33 ft 10 m 18 Awg 53 ft 16 m 16 Awg 84 ft 26 m 14 Awg 134 ft 41 m C493M G 11 97 9 HEATER BLOWER KIT INSTALLATION To install the HB1500 HB1524 heater blower kit perform the following steps 1 Remove the cover Figure 5 item 4 2 Attach the heater pads to each side of the mounting frame below the tilt table assembly 3 Attach the PC board fan assembly to the mounting frame to the left or right of the tilt table assembly see Figure 2 4 The blower is factory wired to the PCB assembly 5 Close and lock the cover PCB FAN ASSEMBLY HEATER PAD 2X Figure 2 Heather Blower Installation Connect the heaters to the PCB assembly as shown in Figure 3 120 VAC MODEL einsehen o H ro INPUT AC LOW NEUTRAL THERMOSTAT GROUND DID FAN HEATER WHITE we HEATER o S S OONAN o TERMINAL BLOCK 24 VAC MODEL O INPUT AC HIGH INPUT AC LOW NEUTRAL GROUND DIODE BRIDGE FAN CAP HEATER A oS la HEATER THERMOSTAT DID OOOO O O G COONAN PYON o O WHITE TERMINAL BLOCK Figure 3 Heater Blower Wiring Diagram 10 C493M G 11 97 TAMPER SWITCH INSTALLATION The HS1500 enclosure comes standard from the factory with a tamper switch installed Should it become necessary
6. C493M F 1 96 Rev F Revised to include updated specification description installation instructions and part numbers for tamper switch update per ECO 95 397 C493M G 1 97 Rev G Revised to new format Updated heater blower information to indicate blower operated in continuous duty mode Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Copyright 1997 Pelco All rights reserved Endura and ExSite are trademarks of Pelco DLP is a registered trademark of Texas Instruments Inc PELLO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
7. INSTALLATION HS1500 High Security Enclosure C493M G 11 97 Contents Important Safeguards and Warnings ias cis dane vars ee en a are lan ada ita sodas 4 DESEHIPLION dd ll dial 5 PP A AA 5 OPHONS it td dd a la ad dai deta 5 IS TAM AMON tas cebo ias id ii ii tilo bois ta bee beis 6 Geiling Mountingitkl sh seras rara sd de ns a 6 Misal MIA da 6 HB1500 HB1524 Heater BloweriKit coccion o een ie Pa meme 9 Recommended Cable Size ascos ts dnd aan in dae ais 9 Heater Blower Kit Installation u cis o edges 10 Tamperswrtchiinstallation i c 2 Pace akiganddd se ahabtxaededs A A ER EEN 11 Tamper Switch Wing e eis denies dein ei bie whee hdd es ee Meh ae ide ccd anaes ahd 11 Exploded Assembly Diagram cito A a Modan edie id ai 12 SPECIICAMONS aaa lve atin ee ae EEN a Rene Rae NRE eels 13 List of Illustrations 1 HStS00kE Installation rr A nha beastie eee eae deeds is 6 2 Heather Blower Installation orina jr ea else Isa 10 3 Heater Blower Wiring Diagrami sss ecsiacccaNees A Faber aan en Ni dada 10 4 Tamperswitchinstallation ca a er Ad A sears 11 5 HS1500 Enclosure Exploded Assembly Diagram ooo 12 6 HS1500 Enclosure Dimension Drawing 2 enn enter nnn ees 13 List of Tables A HS1500 Enclosure Exploded Assembly Parts Lists 2 0 0 0 cnn eben tenn eee 12 C493M G 11 97 3 Important Safeguards and Warnings Prior to installation and use of this product the following WARNINGS should be observed 1
8. MID WALL MOUNTING To mount the HS1500 enclosure mid wall use the optional hood HS1500H and perform the following steps see Figure 1 1 Determine the position for the hood Using it as a template mark and drill holes in the mounting surface 2 Attach the hood with the required fasteners minimum 3 8 diameter recommended 3 Continue with steps 1 8 listed above in Ceiling Mounting section Figure 1 HS1500H Installation 6 C493M G 11 97 CEILING 1 87 CORNER 6 00 3 8 DIA FASTENERS RECOMMENDED 70909 os C493M G 11 97 7 This page intentionally left blank C493M G 11 97 HB1500 HB1524 HEATER BLOWER KIT The HB1500 HB1524 heater blower kits require either 120 VAC or 24 VAC respectively The heater provides 80 watts of heat and is thermostatically controlled to turn on at 40 F 4 44 C and turn off at 60 F 15 56 C The three watt fan is on continously to provide internal air circulation RECOMMENDED CABLE SIZE The following cable sizes are the minimum recommended for use with the combination of blower heater camera AN CAUTION When using a single power source for both the camera and accessories the camera power consumption must be taken into consideration when determining the wire gauge Model Input Voltage Power Consumption Cable Size Cable Distance HB1500 120 VAC 85 Watts 22 Awg 524 ft 160 m 20 Awg 834 ft 254 m 18 Awg 1327 ft 404 m 18 Awg 210
9. ding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP dis plays The lamp and color wheel will be covered for a period of 90 days The air ilter is not covered under warranty Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of
10. ed heater HS1500H Hood for mid wall mounting of HS1500 enclosure C493M G 11 97 5 Installation NOTE The four 4 fasteners required to secure the HS1500 to a wall minimum 3 8 diameter recommended are not supplied Before installing the HS1500 to a wall make certain that the mounting surface is able to support the full weight of the enclosure plus the camera and lens The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure CEILING MOUNTING FLUSH To mount the enclosure to a wall tight to the ceiling follow the steps outlined below 1 Remove the cover from the mounting bracket A special socket is provided fits 1 4 square drive 2 Using the mounting bracket see Figure 4 or the template provided mark and drill holes in the mounting surface NOTE A plate is provided to prevent access through the top of this enclosure If needed it is mounted with the mounting bracket using the same mounting holes and hardware 3 Attach the enclosure with the required fasteners 4 Route the required cables through the back and or top 5 Mount the camera lens to the tilt table 6 Make all appropriate connections i e camera power video coax lens 7 Position the camera and tighten the 1 4 20 fasteners to secure the tilt table in place 8 Replace the cover and check that all components clear Secure the cover with the 1 4 20 Tampruf screw provided
11. ght HS20004215COMP 9 Switch tamper SWI1DM401 A 2 Screw 1 4 20 x 1 2 round Tampruf 10 SS ZH1 4 20X 50SRT B Screw 1 4 20 x 3 4 round Tampruf 10 SS ZH1 4 20X 75SRT C 2 Tape two sided acrylic x inch ZHTAPE1 00X 025 D 2 Bolt 1 4 20 x 5 8 hex head C S SS ZH1 420X 625CH 2 Nut hex 1 4 20 SS ZH1 4 20NUTCH F 4 Washer split lock 1 4 SS ZH1 4LWSSL G 7 Washer flat 3 16 special SS ZH260X562X65C H 4 Washer flat 15 16 SS 2H932X1 75X130 4 Nut lock 1 4 20 Nylon insert SS ZH1 420NUTCHN J 1 Socket Tampruf 10 1 4 drive not shown ZTSOCKET10 C493M G 11 97 Specifications MECHANICAL Window Camera Mounting Maximum Camera Lens Size Enclosure Mounting Security Tamper Switch ELECTRICAL Cable Entry Tamper Switch Wire Leads GENERAL Construction Finish Dimensions Environment Unit Weight 1 2 12 7 mm thick impac Adjustable tilt table Accepts camera lens comb 20 32 cm x 10 16 cm x 10 Four 4 390 99 cm diam and abrasion resistant clear Lexan inations including BNC connector up to 8 0 L x 4 0 W x 4 0 H 6 cm eter holes on protected rear surface Tamper resistant screw N O N C switch contact on cover Plunger type door switch w ith pull to cheat feature N O N C contacts clearly marked on body of switch DM electrical rating 10A 25V Access through back and top 1 4 0 63 cm quick connect N O N C clearly marked on switch body
12. h security camera enclosure of medium size designed for indoor corner mount installation for such applications as elevators parking garages classrooms detention cells etc requiring maximum protection from vandalism in an unobtrusive package Designed to fit flush to the ceiling in a corner an optional hood HS1500H allows the HS1500 to be mounted lower on the wall and still retain the enclosure s integrity An impact resistant clear Lexan window is supplied Constructed of heavy gauge steel the HS1500 will accept most small CCD cameras with fixed focal length lenses ranging in size from 4 mm to 75 mm There is no exposed mounting hardware securing the HS1500 to its mounting surface Opening the enclosure can only be accomplished with a specially designed tool eliminating the possibility of the enclosure being opened by unauthorized personnel In addition a factory installed tamper switch is mounted on the secured access cover MODELS HS1500 High security corner mount enclosure designed to fit flush with the ceiling For use in applications such as elevators parking garages classrooms detention cells etc requiring maximum protection from vandalism in an unobtrusive package OPTIONS HB1500 120 VAC thermostatically controlled heater Provides 80 watts of heat which activates ON at 40 F OFF at 60 F Also includes fan that provides continuous internal air circulation HB1524 Same as HB1500 except 24 VAC thermostatically controll
13. profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska