Home
Pelco FR8308 User's Manual
Contents
1. RK5000PS 3U rack mount chassis provides 12 single width module slots and a power supply RK5000 3U rack mount chassis provides 14 single width module slots a power supply is not included Power to the modules can be supplied using the optional external power supply EPS5000 120 For additional information refer to the RKS5000PS 3U RK5000 3U Fiber Rack Mount Chassis Installation manual RK5000PS 5U Designed to accommodate Endura modules but can also accommodate fiber optic modules with the use of the appropriate adapter kit The RK5002 1UEXP adapter kit is required for installation of the FT8308 transmitter FR8308 receiver into the RK5000PS 5U chassis For information about the RK5000PS 5U chassis refer to the 5000 5 50 Rack Mount Chassis Installation manual NOTE The FT8308 transmitter FR8308 receiver is a double width fiber optic module that occupies two slots in the RK5000PS 3U RK5000 3U and RK5000PS 5U chassis C1647M 3 05 MOUNTING THE TRANSMITTER RECEIVER TO A WALL The FT8308 transmitter FR8308 receiver can be mounted to a wall in the following ways Using the supplied wall clip for attachment of a single module to a wall For installation instructions refer to the Mounting the Transmitter Receiver Using the Wall Clip section below Using the optional WM5002 wall mount kits which are designed for mounting of double width fiber optic modules The WM5002 3U base kit allows a
2. 62 5 125 um 1310 nm 20 dB 1 km 0 6 mi 15 6 mW Single mode a8 9 125 um 1310 nm 20 dB 30 km 18 6 mi 15 6 mW The FT8308 transmitter FR8308 receiver is classified by the FDA as a Class 1 laser product When using 50 125 um fiber subtract 3 dB from the optical power budget tt Maximum transmission distance is limited by fiber bandwidth Maximum transmission distance is based on attenuation of 0 5 dB km plus a 5 dB buffer for connector and splice losses C1647M 3 05 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products and the following fixed camera models CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and CC3651H 2X Three years on all other fixed camera models including Camclosure Integrated Camera Systems and Genex Series multiplexers server and keyboard Two years on all standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM8500 CM9500 CM9700 Matrix DF5 and DF8 Series Fixed Dome products e Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades e Eighteen month
3. 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 19 Use only installation methods and materials capable of supporting four times the maximum specified load C1647M 3 05 3 CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so The product and or manual may bear the following marks VN This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK A This symbol indicates that there are important operating and maintenance instructions in the DO NOT OPEN literature accompanying this unit C1647M 3 05 Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commer
4. Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number and provide the following information 1 Model and serial number 2 Date of shipment number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sen
5. km 18 6 mi e Exceeds all requirements for the RS 250C Medium Haul Transmission specification e Compatible with NTSC PAL and SECAM video standards e No performance adjustments required e 12 VDC or 24 VAC power supply e Standalone and rack mountable modular design e indicators for monitoring of signal status and operating power B NOTE The FT8308 transmitter FR8308 receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825 1 Edition 1 2 2001 08 6 C1647M 3 05 MODELS The FT8308 FR8308 fiber transmitter and recei Multimode Models FT8308MSTR Eight channel fiber op FR8308MSTR Eight channel fiber op Single Mode Models FT8308SSTR Eight channel fiber optic vi FR8308SSTR Eight channel fiber optic vi FT8308SFCR Eight channel fiber optic vi FR8308SFCR Eight channel fiber optic vi OPTIONAL ACCESSORIES The following optional accessories are availab WM5002 3U WM5002 3UEXP Wall mount expansion kit RK5000 3U 19 inch rack mount chassi RK5000PS 3U 19 inch rac EPS5000 120 RK5001B 3U RK5002B 3U RK5002 1UEXP C1647M 3 05 ver consist of the following series of models ic video transmitter multimode ST connector ic video receiver multimode ST connector deo transmitter single mode ST connector deo receiver single mode ST connector deo transmitter single mode FC connector deo receiver single mode FC connect
6. two Phillips pan head screws provided for the clip C1647M 3 05 13 lt FLANGE 23 vERTICAL MOUNTING HOLE 2 lt HORIZONTAL MOUNTING HOLE 2 TRANSMITTER RECEIVER A LOWER SCREW PHILLIPS gt FLANGE PAN HEAD WITH LOCK WASHER 2 i 9 Figure 6 Mounting the FT8308 Transmitter FR8308 Receiver Using the Wall Clip C1647M 3 05 CONNECTIONS Connections to the FT8308 transmitter and the FR8308 receiver are made on the rear panel of the modules and consist of the following e Power connection NOTE A 12 VDC or 24 VAC power supply can be used to power the transmitter receiver when used as a standalone module A 12 VDC power supply is provided If a 24 VAC power supply is used the power supply must be a Listed Direct Plug In Power Unit marked as Class 2 and rated as 24 VAC 200 mA minimum output e Fiber connection e Video input connections transmitter only e Video output connections receiver only Figure 7 provides an illustration of FT8308 transmitter FR8308 receiver connections POWER ALARM CONNECTION FOR RACK MOUNTED MODULE e lt a POWER CONNECTION FOR STANDALONE MODULET nt cei FIBER OPTIC CABLE COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE 111 t f TIT REFER TO THE RK5000PS 3U RK5000 3U FIBE
7. INSTALLATION FT8308 FR8308 Fiber Transmitter and Receiver Eight Channel Digitally Encoded Video C1647M 3 05 Contents Important Safety Instructions 3 Regulatory Notices 3 2 iis seres em Ra Rr ev ab RERE OS 5 Product Overview 00 0 eee eee nee m e 6 Powe eee eer Id REFUS 6 nis O 7 Optional Accessories bem RR re Re Ga REY 7 Front Panel esses IL Wege nesses ox 8 Front Panel FT8308 8 Front Panel FR8308 Receiver 9 Rea Panel tete ten eet eT cde et ey 0 Rear Panel FT8308 Transmitter 0 Rear Panel FR8308 Receiver 1 2 Package Contents sse ocior debet ec e ped amd E Ra 2 Mounting PPP 2 Mounting the Transmitter Receiver into a Rack 2 Mounting the Transmitter Receiver to a 3 Connections tenn ee 5 TreubigshoaOtligs sco ort ERR EE ROS heed RN E REN 6 Specifications east eed bona rb 8 List of Illu
8. R RACK MOUNT CHASSIS INSTALLATION MANUAL FOR INFORMATION TTHE STRIPED WIRE OF THE SUPPLIED 12 VDC POWER SUPPLY CONNECTS TO THE PIN 1 SCREW TERMINAL DC OF THE STANDALONE POWER CONNECTOR THE OTHER WIRE CONNECTS TO THE PIN 2 SCREW TERMINAL DC Figure 7 FT8308 Transmitter FR8308 Receiver Connections C1647M 3 05 15 Troubleshooting LED indicators on the front panel of the FT8308 transmitter FR8308 receiver refer to Figure 2 and to Figure 3 respectively allow you to monitor signal status and operating power Table A provides information about the front panel indicators and associated troubleshooting guidelines Table A Troubleshooting with Front Panel Indicators Indicator Color Possible Cause Power LED Pelco badge Corrective Action Blue Pelco logo lights Power is being applied to the module No action required Blue Pelco logo does not light Power is not being applied to the module Power connection is faulty Check power connection If module is rack mounted reseat module or power supply as necessary Power supply has failed Replace power supply Loss of power occurs due to tripped circuit breaker s blown fuse s or faulty electrical service Check circuit breaker s fuse s or electrical service as necessary Video Present LED Green Incoming video signal is present on the channel No action required Red on transmitter I
9. cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme 003 du Canada C1647M 3 05 5 Product Overview DESCRIPTION The FT8308 FR8308 fiber transmitter and receiver provide the ability to transmit up to eight composite video channels over one optical fiber refer to Figure 1 EIGHT EIGHT VIDEO VIDEO INPUTS OUTPUTS FT8308 FR8308 jd TRANSMITTER ONE RECEIVER FIBER Figure 1 Eight Channel Video FT8308 Transmitter and FR8308 Receiver Features of the FT8308 FR8308 fiber optic transmission system include the following e 8 bit digitally encoded video for high quality multi channel video transmission over a single fiber e Multimode fiber support for distances up to 1 km 0 6 mi e Single mode fiber support for distances up to 30
10. l of the modules The following sections provide a view of the rear panel of the FT8308 transmitter and the FR8308 receiver REAR PANEL FT8308 TRANSMITTER Figure 4 illustrates the rear panel of the FT8308 transmitter Figure 4 Rear Panel of FT8308 Transmitter RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STANDALONE POWER CONNECTOR 2 pin connector for power connection of standalone module removable mating connector with screw terminals not shown VIDEO IN CONNECTORS 1 8 75 ohm BNC analog video input FIBER OPTIC CONNECTOR ST or FC dependent on FT8308 model o For additional information about rear panel connections refer to the nstallation section 10 C1647M 3 05 REAR PANEL FR8308 RECEIVER Figure 5 illustrates the rear panel of the FR8308 receiver VIDEO OU oo o o Figure 5 Rear Panel of FR8308 Receiver RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STANDALONE POWER CONNECTOR 2 pin connector for power connection of standalone module removable mating connector with screw terminals not shown T CONNECTORS 1 8 75 ohm BNC analog video output FIBER OPTIC CONNECTOR ST or FC dependent on FR8308 model For additional information about rear panel connections refer to the nstallation section C1647M 3 05 Installati
11. ncoming video signal is not present on the channel Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Check BNC connections Coaxial cable is defective Replace cable Continued on next page C1647M 3 05 Table A Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Video Present LED Continued Red on receiver Incoming video signal is not present on the channel Optical signal is not being received from the transmitter Carrier Detect LED is also red Refer to the Carrier Detect LED troubleshooting section below Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Check BNC connections Coaxial cable connected to the transmitter is defective Replace cable Carrier Detect LED Receiver Only Green The optical signal is No action required being received from the transmitter Red The optical signal is Transmitter is not Check power not being received from the transmitter powered on connections Replace power supply if necessary Fiber optic cable is not connected Check fiber optic connections Fiber optic cable connectors are dirty or are damaged Clean polish or replace fiber optic cable c
12. on PACKAGE CONTENTS The following items are supplied With the FT8308 transmitter Regulated switching power supply with four plug adapters North American Australian U K and European configurations 100 240 VAC input 12 VDC input Wall clip with two 4 40 x 250 inch Phillips pan head screws with lock washers for attachment of single module to wall FT8308 FR8308 Fiber Transmitter and Receiver Installation manual this manual With the FR8308 receiver Regulated switching power supply with four plug adapters North American Australian U K and European configurations 100 240 VAC input 12 VDC input Wall clip with two 4 40 x 250 inch Phillips pan head screws with lock washers for attachment of single module to wall FT8308 FR8308 Fiber Transmitter and Receiver Installation manual this manual MOUNTING The FT stand moun 8308 transmitter FR8308 receiver can be mounted into a rack or can be used as a alone module As a standalone module the unit can be placed on a desktop or can be ed to a wall MOUNTING THE TRANSMITTER RECEIVER INTO A RACK The FT8308 transmitter FR8308 receiver can be installed into an RK5000 Series rack mount chass The R is which can be mounted into an industry standard 19 inch 48 26 cm equipment rack K5000 Series rack mount chassis includes the following models RK5000PS 3U and RK5000 3U Designed to accommodate fiber optic modules as ollows
13. onnectors as necessary Fiber optic cable is defective Replace cable A problem exists with the optical power budget Verify that losses in fiber optic cable do not exceed the optical power budget specification of the fiber optic link If the losses do exceed the optical power budget contact Product Support C1647M 3 05 Specifications VIDEO umber of Channels odulation Type Video Input Bandwidth Gain Crosstalk Differential Gain Differential Phase Tilt Signal to Noise Ratio GENERAL Operating Temperature Input Power Requirements LED Indicators Transmitter Receiver Dimensions Unit Weight MECHANICAL Connectors Video Rack Power Alarm Standalone Power Fiber Optic 8 Pulse code modulation 8 bit resolution 1 0 Vp p 75 ohms NTSC PAL and SECAM 6 5 MHz Unity 50 dB typical at 3 58 MHz lt 1 1 29 lt 1 gt 60 dB CCIR weighted 40 to 167 F 40 to 75 C 12 VDC or 24 VAC 460 mA Power Video Present per channel Power Video Present per channel Carrier Detect 8 75 D x 2 28 W x 4 81 H 22 23 x 5 79 x 12 22 cm 2 56 Ib 1 16 kg BNC per channel 4 pin connector 2 pin connector screw terminal ST for multimode fiber ST or FC for single mode fiber OPTICAL POWER BUDGET TRANSMISSION DISTANCE AND LASER CLASS 1 LIMIT Optical Maximum Laser Power Transmission Class 1 Fiber Wavelength Budget Distance Limit Multimode t an
14. or Wall mount base kit for double width module External redundant power or double width module s for 14 slots no power RUs mount chassis for 12 slots with power 3 RUs supply 1 RU 120 W x 2 Blank filler panel single width Blank filler panel double width Adapter kit that allows a 3 RU double width fiber optic module to be used in RK5000PS 5U rack mount chassis FRONT PANEL The front panel of the FT8308 transmitter and the FR8308 receiver provides LED indicators that allow you to monitor signal status and operating power The following sections provide a view of the front panel of the FT8308 transmitter and the FR8308 receiver FRONT PANEL FT8308 TRANSMITTER Figure 2 illustrates the front panel of the FT8308 transmitter Perco 00 0 Y 000000000 L Figure 2 Front Panel of FT8308 Transmitter VIDEO PRESENT LEDs 1 8 o POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section C1647M 3 05 FRONT PANEL FR8308 RECEIVER Figure 3 illustrates the front panel of the FR8308 receiver Figure 3 Front Panel of FR8308 Receiver VIDEO PRESENT LEDs 1 8 CARRIER DETECT LED POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section C1647M 3 05 9 REAR PANEL Connections to the FT8308 transmitter and the FR8308 receiver are made to the rear pane
15. ovided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus 16 WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Installation should be done only by qualified personnel and conform to all local codes 18 Unless the unit is specifically marked as a NEMA Type 3 3R 35 4 4X 6 or
16. s on DX Series digital video recorders and NVR300 Series network video recorders e year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the
17. strations NOP WN Eight Channel Video FT8308 Transmitter and FR8308 Receiver 6 Front Panel of FT8308 25 8 Front Panel of FR8308 9 Rear Panel of FT8308 2 5 10 Rear Panel of FR8308 Receiver 11 Mounting the FT8308 Transmitter FR8308 Receiver Using the Wall Clip 14 FT8308 Transmitter FR8308 Receiver 15 List of Tables A Troubleshooting with Front Panel 16 C1647M 3 05 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are pr
18. t by a COURIER SERVICE send the If the goods are to be sent by a FREIGHT FORWARDER send the goods to goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C1647M 3 05 Original version Pelco the Pelco logo Spectra Genex Legacy Esprit and Camclosure are registered trademarks of Pelco Endura is a trademark of Pelco Copyright 2005 Pelco All rights reserved PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
19. ttachment of a single module to the wall The WM5002 3UEXP expansion kit allows attachment of an additional module to the wall It is recommended that a maximum of one expansion kit be used with the base kit allowing a maximum of two double width modules to be attached to the wall NOTE The WM5002 wall mount kits can be used with the WM5001 wall mount kits which are designed for mounting of single width fiber optic modules If mounting a mix of single width and double width modules is desired it is recommended that a maximum of two single width modules and one double width module be mounted in combination with one another For mounting instructions using the wall mount kits refer to the WM5000 Series Wall Mount Kit Installation manual Mounting the Transmitter Receiver Using the Wall Clip NOTE Before mounting the FT8308 transmitter FR8308 receiver to a wall ensure that there is adequate space at both ends for viewing the front panel LEDs and for making the various rear panel cable connections To attach the FT8308 transmitter FR8308 receiver to a wall using the supplied wall clip refer to Figure 6 and do the following 1 Using the two vertical or horizontal wall mounting holes attach the wall clip to a wall using two screws not provided 2 Slidethe module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip 3 Attach the module to the clip using the