Home

Pelco ERD2000 User's Manual

image

Contents

1. MAIN FUSE S 7 T TERMINALS f a ENCLOSURE z INSIDE GROUND L N k N Figure 2 ERD2200 Receiver Figure 3 ERD2200 Power Connections Fuses are installed for 115 VAC operation For 230 VAC operation install the appropriate fuses supplied Refer to Figure 2 Input Power Enclosure Main 115 VAC 4A 5A 230 VAC 2A Kai 2 Set the power selector switch to either 115V or 230V to match your input power Refer to Figure 2 3 Loosen the thumbscrew and lift out the door protecting the power terminals refer to Figure 2 4 Connect main power The bottom of the housing has five conduit entries fittings not supplied to bring wiring into the receiver Connect 115 230 VAC to the Main Power In terminals inside the receiver refer to Figure 3 with AC high going to the L line terminal and AC low to the N neutral terminal Connect ground wire to the stud inside the housing Do not turn on power 5 Connect enclosure power optional If you have an enclosure with heater blower or defroster connect wires from the pan tilt or enclosure to the Enclosure Power Out terminals inside the receiver refer to Figure 3 The enclosure must use the same power as the receiver Refer to Figure 4 for steps 6 12 6 Connect the camera power If your camera uses 24 VAC connect the camera to the CAM PWR connector on the front of the receiver The camera s power must not
2. nnect the pan tilt controls up down left right and common Refer to Figure 2 for connection of P T ground wire 10 Co 11 Co nnect the motorized lens controls iris focus zoom and common nnect video VIDEO IN comes from the camera VIDEO OUT goes to the controller If necessary refer to Table B in the Wiring Tables section to determine appropriate coaxial cable types for video applications 12 Co nnect the auxiliary outputs optional AUX 1 is a 5 VDC 20 mA maximum open collector output Use the auxiliary To operate low current relays To turn on or off a Pelco window wiper that has TTL circuitry AUX 2 is a normally open normally closed Form C relay Relay contacts are rated at 1A maximum at 24 VDC or 5A maximum at 115 VAC 13 Do uble check all wiring connections and then turn on power C1506M A 8 02 7 IRD2024 WIRING Rear View of Receiver 24m 115 230V _ gt 50 60HZ 50 60HZ A A A Cc C c 24V 50 60HZ POWER SELECT INPUT POWER Front View of Receiver Rini I PWR dood H Ed lata cc CNN ae 24V 1A IFZC ty CAM PWR CT oc PAN TILT LENS AUX1 AUX2 Figure 5 IRD Wiring and Switch Setting 1 Connect power to the 24 VAC INPU
3. RA and provide the following information Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii If you are located outside the continental U S Alaska Hawaii or Puerto Rico or Puerto Rico Intermediate Consignee Ultimate Consignee Service Department American Overseas Air Freight Pelco Pelco 320 Beach Road 3500 Pelco Way 3500 Pelco Way Burlingame CA 94010 Clovis CA 93612 5699 Clovis CA 93612 5699 USA USA Pelco the Pelco logo Spectra Genex Esprit Camclosure and Legacy
4. whether it is communicating in standard or extended Coaxitron mode Refer to your transmitter controller manual for the exact key press sequence required to send an Aux 1 or Aux 2 command The following explains how the auxiliaries respond with the different Coaxitron modes Standard Coaxitron When a valid Aux 1 or Aux 2 command is received the corresponding auxiliary operates momentarily Extended Coaxitron When a valid Aux 1 or Aux 2 command is received the corresponding auxiliary operates momentarily Optional Latching Mode Extended Coaxitron Only When a valid Aux 3 or Aux 4 command is received the corresponding auxiliary performs a latching operation NOTE Aux 3 operates Aux 1 and Aux 4 operates Aux 2 C1506M A 8 02 9 FUSE REPLACEMENT N CAUTION These service instructions are for use by qualified service personnel only To reduce the risk of electrical shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so IRD2024 Lens Auxiliary Fuse A 500 mA fuse protects the LENS and AUX 1 outputs Remove the cover of the receiver to check the fuse ERD2200 Main Fuse The main fuse protects the pan tilt output when 24 VAC pan tilt operation is selected It also protects the 24 VAC camera output Refer to the FRD2200 Wiring section for fuse location and values Enclosure Fuse The enclosure fuse protects the pan tilt output when
5. are registered trademarks of Pelco Copyright 2002 Pelco All rights reserved REVISION HISTORY Manual Date Comments C1506M 3 00 Original version C1506M A 8 02 Revised manual per ECO 02 8195 to meet UL standards Added FCC notice C1506M A 8 02 15 PELCO World Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 Orangeburg New York Las Vegas Nevada Eindhoven The Netherlands Wokingham United Kingdom Montreal Canada
6. exceed 5 VA If your camera uses 115 or 230 VAC connect the camera s power leads to the Enclosure Power Out terminals inside the receiver The camera s power must be the same as the receiver s power Main Power In terminals 7 Replace the door over the power terminals 6 C1506M A 8 02 Rear View of Receiver Sen 24V 50 60HZ FROM 415 230V __ A 50 60HZ FACTORY i 115 230V D c PIT ce 24V 50 60HZ POWER SELECT INPUT POWER ERD OPTION Front View of Receiver Kol ol Bol be tyre CT aa TEE L CNN PAN TILT LENS v oc AUX1 AUX2 Figure 4 ERD Wiring and Switch Setting 8 Set the P T SELECT switch on the rear of the receiver according to the pan tilt voltage requirements 115 230 VAC position If your pan tilt uses 24 VAC remove the label over the switch and set i PAN TILT VOLTAGE WARNING The P T POWER SELECT switch is set at the factory in the the switch for 24 VAC You will damage a 24 VAC pan tilt if you operate it at 115 230 VAC If you select 24 VAC the maximum output is 48 VA supplied by the transformer inside the receiver make sure the combined output of your pan tilt and camera if it also uses 24 VAC does not exceed this output 9 Co
7. green CX LED blinks RANDOM AUTO SCANNING Operation of random and auto scanning depends on whether your transmitter controller is communicating with the IRD2000 ERD2200 in standard or extended Coaxitron mode Standard Coaxitron Press the Pan Auto or Autoscan key to begin random scanning In random scan operation the pan tilt travels between the limit stops with a random scan period of 0 60 seconds The pan tilt then stops for a random period of 0 60 seconds before starting another random scan period The direction the pan tilt moves when another scan period is started is also randomly determined When a pan limit stop is reached scan direction reverses automatically Press the Pan Auto or Autoscan key again to start auto scanning After approximately a half hour of auto scanning the pan tilt switches to random scanning To turn off random auto scanning press the Pan Man or Manscan key Extended Coaxitron Activate random auto scanning by calling the following presets Preset 97 Random scanning Preset 98 Continuous auto scanning see WARNING below Preset 99 Auto scanning with half hour timeout after which pan tilt switches to random scanning Preset 96 Stop scanning WARNING Activating preset 98 continuous auto scanning reduces the warranty on your pan tilt to six months AUXILIARY OPERATION Operation of the two auxiliaries varies depending on the transmitter controller you are using and
8. instructions Heed all warnings m ollow all instructions aR ON os ES o not block any ventilation openings Install in accordance with the manufacturer s instructions 6 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 7 Only use attachments accessories specified by the manufacturer 8 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 9 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture the apparatus does not operate normally or the apparatus has been dropped 0 To reduce the risk of shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so 1 An ALL POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building 2 Only use replacement parts recommended by Pelco 3 The installation method and materials should be capable of supporting four times the weight of he ap
9. 115 230 VAC pan tilt operation is selected It also protects the enclosure output Refer to the FRD2200 Wiring section for fuse location and values Lens Auxiliary Fuse A 500 mA fuse protects the LENS and AUX 1 outputs Remove the cover of the receiver inside the housing to check the fuse 10 C1506M A 8 02 TROUBLESHOOTING Check the wiring connections If the CX LED does not blink when commands are sent to the receiver make sure the controller is working properly Also check the video coaxial cable between the controller and the VIDEO OUT connection on the receiver An LRD41TLC Test Local Control Module is available from Pelco to test or troubleshoot your receiver pan tilt and lens functions directly from the receiver This lightweight hand held keypad tests the up down left and right functions of the pan tilt and the iris open close focus near far and zoom telephoto wide functions of the lens 1 Plug the module into the TLC connector on the front of the receiver The module can be plugged in with the receiver s power turned on 2 Push the buttons on the keypad to test your equipment The TLC module can be used without disconnecting the receiver from the controller The TLC module will override any signals from the controller C1506M A 8 02 11 WIRING TABLES Table A 24 VAC Wiring Distances Table The following are the recommended maximum wire distances transformer to load for 24 VAC applications and are
10. INSTALLATION OPERATION IRD ERD2000 Series Receiver C1506M A 8 02 ce Soft LISTED C1506M A 8 02 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNNNGG 4 DESCRIPTION RR ee len een ana 5 MODELS a re ee EE 5 MOUNTING ae RT Ener 5 ERD2200 WIRING see ren Erna 6 IRD 2024 WIRING eege leese 8 OPERATION ass sinne inanerfern 9 RANDOM AUTO SCANNING see 9 STANDARD GOAXIMRON SS anse nne N a e EE 9 EXTENDED GOAXITRON tinii 9 AUXILIARY OPERATION 4s 0 d ccceanranaeseriisstseatatientrabantnendadandiaanennasiaieantneds 9 STANDARD COAXITRON Frens REEE 9 EXTENDED COAXITRON 9 FUSE REPLACEMENT nsss 10 EK e e ea raa E a E EEA AE EAN diss Aa T AR R 10 CENS AUXILARY FUSE nn E RR 10 STE UE 10 MAIN FUS Esasen i 10 ENCLOSURE E 10 LENS AUXILIARY FUSE teresse en noA 10 TROUBLESHOOTING ran nuai a E E tas 11 WIRING TABLES ease esse ash 12 SPEGIEIGATIONS ee 13 EELER 14 WARRANTY AND RETURN INFORMATION nennen 15 LIST OF ILLUSTRATIONS Figure Page 1 UMotinting Methods Ee Ae 2 ERD2200 Receiver 2 ERD2200 Power Connections 4 ERD Wiring and Switch Setting sssssssssssssseseaseneeaatittineetsnnnsssssssssssnnnnnnnnrnnnntnrtnnrennnnnnnenet 7 5 IRD Wiring and Switch Setting 8 LIST OF TABLES Table Page A 24 VAC Wiring Distances Table 12 B Video Coaxial Cable Requirements 12 C1506M A 8 02 3 IMPORTANT SAFEGUARDS AND WARNINGS Read these instructions Keep these
11. Minimum cable requirements 75 ohms impedance All copper center conductor All copper braided shield with 95 braid coverage C1506M A 8 02 SPECIFICATIONS ERD2200 Electrical Input Voltage 115 230 VAC 50 60 Hz Output Voltage Camera 24 VAC or 115 230 VAC if using enclosure power Lens 8 VDC Pan Tilt 24 115 230 VAC Enclosure 115 230 VAC Power Consumption Receiver 90 VA maximum including 48 VA maximum at 24 VAC for pan tilt and camera 5 VA maximum for camera Fuses Main 115 VAC 5A 230 VAC 25A Enclosure 115 VAC 4A 230 VAC 2A Lens Aux 1 DA Video Input Output 75 ohms Video Bandwidth 10 MHz Video Gain Unity Video Formats NTSC or PAL Control ethod Standard or extended Coaxitron Auxiliary Outputs One open collector TTL One N O N C Form C relay Mechanical Video Connectors BNC P T Camera Auxiliary Lens Power Connectors Screw terminals Cable Entry Openings for 75 inch 1 91 cm conduit General Environment Outdoor Construction Aluminum receiver steel housing Finish Gray polyester powder coat Operating Temperature 50 to 122 F 46 to 50 C Dimensions 15 2 L x 12 2 W x 5 0 H inches 38 6 x 31 0 x 12 7 cm Weight 9 90 Ib 4 50 kg Certifications Ratings CE Class B UL Listed UL Listed to Canadian safety standards NEMA 4 IP 66 C1506M A 8 02 IRD2024 Electrical Input Voltage 24 VAC 50 60 Hz Outp
12. T connector on the rear of the receiver The receiver s power requirement is a maximum of 5 VA not including the camera and pan tilt Refer to the pan tilt manual for its power requirements Do not turn on power If necessary refer to Table A in the Wiring Tables section to determine appropriate wire sizes for 24 VAC applications 2 Make sure the P T SELECT switch on the rear of the receiver is set toward 24 VAC The 115 230 VAC switch position is used only with the ERD2200 3 Connect the pan tilt controls up down left right and common 4 Connect the camera power 24 VAC 5 Connect the motorized lens controls iris focus zoom and common 6 Connect video VIDEO IN comes from the camera VIDEO OUT goes to the controller If necessary refer to Table B in the Wiring Tables section to determine appropriate coaxial cable types for video applications 7 Connect the auxiliary outputs optional AUX 1 is a5 VDC 20 mA maximum open collector output Use the auxiliary e To operate low current relays e To turn on or off a Pelco window wiper that has TTL circuitry AUX 2 is a normally open normally closed Form C relay Relay contacts are rated at 1A at 24 VDC or 5A at 115 VAC 8 Double check all wiring connections and then turn on power 8 C1506M A 8 02 OPERATION When power is applied to the receiver the green PWR LED on the receiver lights Whenever the receiver gets a valid Coaxitron control signal the
13. calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Distances are calculated in feet values in parentheses are meters Wire Gauge 20 18 16 14 12 10 10 283 86 451 137 716 218 1 142 348 1 811 551 2 880 877 20 141 42 225 68 358 109 571 174 905 275 1 440 438 30 94 28 150 45 238 72 380 115 603 183 960 292 40 70 21 112 34 179 54 285 86 452 137 720 219 50 56 17 90 27 143 43 228 69 362 110 576 175 g o 47 14 75 22 119 36 190 57 301 91 480 146 70 40 12 64 19 102 31 163 49 258 78 411 125 80 35 10 56 17 89 27 142 43 226 68 360 109 g a 31 9 50 15 79 24 126 38 201 61 320 97 100 28 8 45 13 71 21 114 34 181 55 288 87 m 25 7 41 12 65 19 103 31 164 49 261 79 120 23 7 37 11 59 17 95 28 150 45 240 73 130 21 6 34 10 55 16 87 26 139 42 221 67 140 20 6 32 9 51 15 81 24 129 39 205 62 150 18 5 30 9 47 14 76 23 120 36 192 58 EXAMPLE An enclosure that requires 80 VA and is installed 35 feet 10 m or less from the 24 VAC source would require a minimum wire gauge of 20 AWG Table B Video Coaxial Cable Requirements Cable Type Maximum Distance RG59 U RG6 U RG11 U 750 ft 229 m 1 000 ft 305 m 1 500 ft 457 m
14. paratus 4 Use stainless steel hardware to fasten the apparatus to outdoor surfaces 5 For continued protection against risk of fire replace fuses only with the same type fuses The following safeguards and warnings apply only to the IRD2024 model 1 Warning To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 2 Do not use this apparatus near water 3 Clean only with dry cloth 4 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus The product and or manual may bear the following mar Si This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION RISK OF ELECTRIC SHOCK his symbol indicates that there are important DO NOT OPEN perating and maintenance instructions in the iterature accompanying this unit Ho oO Please thoroughly familiarize yourself with the information in this manual prior to installation and operation 4 C1506M A 8 02 DESCRIPTION The IRD ERD2000 Series Receiver operates Pelco s fixed speed pan tilts and domes The receiver works with standard and extended Coaxitron controllers including the CM6700 7500 8500 9500 KBD9000 MPT9000 9008 9500 and MX4000 With Coaxitron control pan tilt and lens control signals are transmitted over the video coaxial cable The control data is
15. s cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 14 C1506M A 8 02 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 CC3700 and MC3500 MC3600 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard Two years on all standard motorized or fixed focal length lenses Two years on Legacy Camclosure Camera Systems CM6700 CM6800 CM8500 CM9500 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cas
16. sette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes see e e oeo e Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent reight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number
17. superim posed on the vertical blanking interval of the video signal Standard features include pan tilt control including auto and random scan camera power lens control zoom iris and focus and two auxiliary outputs The receiver also can be used with the LRD41TLC Test Local Control module which allows on site testing and troubleshooting of system unctions The TLC module plugs into the receiver and operates off the receiver s power MODELS RD2024 Indoor fixed speed Coaxitron receiver 24 VAC input 24 VAC output for camera power and pan tilt operation ERD2200 Outdoor fixed speed Coaxitron receiver 115 230 VAC input 24 VAC output for camera power 24 115 or 230 VAC output for pan tilt operation and 115 or 230 VAC output for enclosure accessories MOUNTING Attach the IRD2024 to a flat surface Attach the ERD2200 to a vertical surface with the conduit entries facing down Use the housing as a template for drilling mounting holes Use 1 4 inch fasteners not supplied of the appropriate length Refer to Figure 1 Fy F ANCHOR OR TOGGLE BOLT WOOD SCREW NOT SUPPLIED e NOT SURPLIED NOT SUPPLIED al a See E ee ee Pathe j vi vi vi vi vi vi Um Se Hy um f I men 14 uf WALLBOARD Be WALL Si EE WALL Een Figure 1 Mounting Methods C1506M A 8 02 5 ERD2200 WIRING POWER P T GROUND TERMINALS STUD POWER SELECTOR SWITCH
18. ut Voltage Camera 24 VAC Lens 8 VDC Power Consumption Receiver 45 VA maximum Fuses Lens Aux 1 DA Video Input Output 75 ohms Video Bandwidth 10 MHz Video Gain Unity Video Formats NTSC or PAL Control Method Standard or extended Coaxitron Auxiliary Outputs One open collector TTL One N O N C Form C relay Mechanical Video Connectors BNC P T Camera Auxiliary Lens Power Connectors Screw terminals General Environment Outdoor Construction Aluminum Finish Black polyester powder coat Operating Temperature 10 to 122 F 23 to 50 C Dimensions 10 3 L x 6 0 W x 1 75 H inches 26 2 x 15 2 x 4 4 cm Weight 1 25 Ib 0 58 kg Certifications Ratings CE Class B UL Listed UL Listed to Canadian safety standards NEMA 1 IP 10 Design and product specifications subject to change without notice REGULATORY NOTICES NOTE This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment doe