1. 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA Green The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002 95 EC This equipment conta
2. E A AS Ads cosh AO o aun erate 9 A RK5B000 3UBACK VIEW suas ny is nada a lidad Nobles so ia 9 5 Mounting an RK5000PS 3U RK5000 3U into a Rack corr 10 635 Modules Stal AION cita da tronos 11 Jo Blank Module Installation iss i822 ee ts cda todd Abs ls pd dd ld dd hl ag 11 Bri Power Bus Removal aaie eaa aat a a a tana 12 9 Internal Power Supply Replacement es seel ca ete naay n a Yee Lad D A eek ly ee ae oon e a oh ee ele 13 C1972M A 10 06 Important Safety Instructions 20 2il The product and or manual may bear the following marks A WARNING This symbol indicates that dangerous voltage constituting a risk of electric Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from
3. View BACK VIEW RK5000 3U 1 External Connector for Redundant Power Supply 2 Thumbscrews for Fastening Modules 14 Figure 4 RK5000 3U Back View C1972M A 10 06 Installation PACKAGE CONTENTS RK5000PS 3U 1 Rack mount chassis 4 Screws and washers for rack mounting RK5000 3U 1 Rack mount chassis 4 Screws and washers for rack mounting MOUNTING A CHASSIS A WARNING To ensure adequate ventilation 1 RU of space is required above and below the RK5000PS 3U The procedure for mounting an RK5000PS 3U and an RK5000 3U into a rack is exactly the same To mount a chassis follow these steps and refer to Figure 5 1 Insert the chassis into the rack 2 Secure the chassis with the supplied screws and washers Figure 5 Mounting an RK5000PS 3U RK5000 3U into a Rack 10 C1972M A 10 06 INSTALLING A MODULE You can install single width or double width modules into the empty slots on the RK5000PS 3U chassis and RK5000 3U chassis To install a module follow these steps and refer to Figure 6 1 Insert the module into an empty slot of the chassis 2 Secure the module by tightening the thumbscrew on the back of the chassis SS Ss eS ee a Figure 6 Module Installation INSTALLING A BLANK MODULE You can use single width or double width blank modules to fill the empty module slots on the chassis To attach
4. being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Use only installation methods and materials capable of supporting four times the maximum specified loa
5. can use the optional EPS5000 120 external power supply which consists of dual 120 watt hot swappable power supplies to power up to two fully populated RK5000 3U chassis The EPS5000 120 is 1 RU high and rack mountable You can fill the empty module slots on either chassis with single width blank modules RK5001B 3U and double width blank modules RK50002B 3U AN WARNING The internal double width power supply must remain in the slots in which it is shipped Do not relocate to the other slots MODELS RK5000PS 3U Rack mountable chassis with power supply 3 RU RK5000 3U Rack mountable chassis 3 RU external power supply required C1972M A 10 06 1 FRONT VIEW RK5000PS 3U O Rack Ears 2 2 Power Supply Module Slots 12 O Alarm from Module LED O Power Fail LED O Pelco Badge 00000 00 00000 0000 y 0000000800 0 So 0 0 00 Figure 1 RK5000PS 3U Front View BACK VIEW RK5000PS 3U 1 Thumbscrews for Fastening Modules 12 2 External Connector for Redundant Power Supply Relay Output Connector with Screw Terminal 4 Power Button O Power Cord Connector PY 2 D0 2 0 0 OD 00020204 Figure 2 RK5000PS 3U Back View 8 C1972M A 10 06 FRONT VIEW RK5000 3U 1 Rack Ears 2 O Module Slots 14 Figure 3 RK5000 3U Front
6. INSTALLATION RK5000PS 3U RK5000 3U Rack Mount Chassis For Fiber Optic Modules C1972M A 10 06 Contents Important Safety INStrUcthans ai A ages A A Ta E E E MAN A A Pace als es hat Oleh ony Rl se LS MSE edb ble Ohi LE A i ht et oi eh hl Des ription see tees tet neat A a eat sted Re at a lea lel aly A tlie be at ma dl ee eh delat Att a Models eden Men tars a to cid toda Front ViewtRKSQ00PS SU lt 2du teats hn tal Beh Se det ll ti dd ir ist e tidad daw Back View RKSQ00RS 3U exc tai weer AA Ar dace a lid anges a eee pare ada ed FONE View AK5O00 Ue Seinen Ata Bo NS le Wt of e tack SSA Secale fe ES el Wal MARA ts Wee WR a ae 3 Back View AKS000 3U A o ae dew weer hes Installation perissa errar a Deke es cand A bak A Bid Roe A dbva anaes toad emote 1 Package Contents a2 a oe ec hie seer O tea dete arte ates 1 Mounting a Chassis ti tnd suid Maleate Mes gan ek RA ne fete oA oie alc yin ea oe wit oa sah ee a 1 stalling a Mod le 0 a a Do Do 1 Installing a Blank Modulen 23 45 2 ies e a a See ds adas ads Lira olas des bbs oll tae 1 SEVIER concen us ee ed re ado o ee Ne ee dable all dos 1 Removing the Power BUS A A A as 1a A Seah Mea ee be a Oe es E bee 1 Replacinaran Internal PO We a ene oe eo 1 SPECIES A o lao 1 C1972M A 10 06 List of Illustrations To RK OOOPS U Front VieWeris epcntcxt ke ch a eed hea de 8 22 HRKSOOORS BU Back Vie Weir amp a A a Mera a hacen ale 8 35 ARKSOOOSSUIFROME VIG W rin ta
7. a blank module follow these steps and refer to Figure 7 1 Insert the blank module into the empty slot on the chassis 2 Secure the blank module by tightening the thumbscrew on the back of the chassis Figure 7 Blank Module Installation C1972M A 10 06 11 Service REMOVING THE POWER BUS You must remove the power bus from the RK5000PS 3U if you want to use the power supplies that are provided with the Fiber modules WARNING Using the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS 3U can cause damage to the unit To remove the power bus follow these steps and refer to Figure 8 1 Turn off the power supply 2 Remove the power supply 3 Unscrew the five Phillips flat head screws Figure 8 Power Bus Removal 12 C1972M A 10 06 REPLACING AN INTERNAL POWER SUPPLY You can easily replace the internal power supply in the RK5000PS 3U in case of failure The front of the power supply has two LEDs The top LED turns red when there is an alarm condition from one of the modules The bottom LED turns red when the power supply fails To replace an internal power supply follow these steps and refer to Figure 9 1 Ze 3 C1972M A 10 06 Unplug the power cord Unscrew the two thumbscrews on the back of the chassis that hold the power supply Remove the power supply Insert the new power supply Secure the po
8. d CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so Only use replacement parts recommended by Pelco CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN shock is present within this unit AN This symbol indicates that there are important operating and maintenance instructions in C1972M A 10 06 the literature accompanying this unit Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will b
9. e required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio and television reception This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada 6 C1972M A 10 06 Description The RK5000PS 3U rack mount chassis supports fiber optic modules The chassis has 12 slots and an internal double width power supply You can insert up to 12 single width modules or a combination of single width and double width modules into the slots For redundancy you can use the optional external power supply EPS5000 120 It provides redundant power for up to two fully populated RK5000PS 3U chassis You can mount the chassis which is 3 rack units RU high into an ElA standard 19 inch rack The RK5000 3U chassis has 14 slots and requires an external power supply You can insert up to 14 single width modules or a combination of single width and double width modules into the slots You can mount the chassis which is 3 rack units RU high into an ElA standard 19 inch rack You
10. in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product lia bility relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 p289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information odel and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number
11. ins electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment ss REVISION HISTORY Manual Date Comments C1972M 11 04 Original version C1972M A 10 06 Pelco the Pelco logo Spectra Genex Esprit Camclosure and Legacy are registered trademarks of Pelco Added Warning to Description section and Mounting a Chassis section Revised electrical specifications Copyright 2006 Pelco All rights reserved Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States
12. ve in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FR FT FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products hree years on Genex Series products multiplexers server and keyboard hree years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty hree years on PMCL200 300 400 Series LCD monitors wo years on standard motorized or fixed focal length lenses wo years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series ixed dome products wo years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays he lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used
13. wer supply by tightening the two thumbscrews on the back of the chassis Plug in the power cord Turn on the power supply Figure 9 Internal Power Supply Replacement Specifications RK5000PS 3U ELECTRICAL Input Voltage Input Current Output Voltage Output Current Fuse Rating Redundant Capability MECHANICAL Number of Slots Module Orientation Rack Units Construction Finish GENERAL Operating Temperature Operating Humidity Storage Humidity Dimensions Mounting Unit Weight RK5000 3U MECHANICAL Number of Slots Module Orientation Rack Units Construction Finish GENERAL Dimensions Mounting Unit Weight 100 240 VAC 1 0A 12 VDC 10A 16A Yes with optional EPS5000 120 power supply 12 for modules and 2 for power supply Vertical 3 Aluminum Black 32 to 122 F 0 to 50 C 80 maximum relative humidity noncondensing 95 maximum relative humidity noncondensing 5 22 H x 18 99 W x 8 85 D 13 26 x 48 23 x 22 48 cm Fits 19 inch EIA standard rack 8 01 Ib 3 63 kg with power supply 25 53 Ib 11 58 kg fully populated 14 for modules Vertical 3 Aluminum Black 5 22 H x 18 99 W x 8 85 D 13 26 x 48 23 x 22 48 cm Fits 19 inch ElA standard rack 5 19 Ib 2 35 kg chassis only 25 63 Ib 11 63 kg fully populated C1972M A 10 06 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defecti
Download Pdf Manuals
Related Search
Related Contents
(RSVVP) User`s Manual Bedienungsanleitung Agora IP 100 pH PLUS LIQUIDE - Piscines & Bains NEC ND-3550 DVD-RW Beige HP EliteBook 8760w Corry's 100099017 Use and Care Manual CS8100 - Airless Sprayers & Spray Equipment Valueline VLEP10020B20 power cable SE-U33GX - オンキヨー株式会社 Copyright © All rights reserved.