Home
Pelco BK4220 User's Manual
Contents
1. Vertical bar in left or right margin indicates change or addition PELLO BK4000 BK4024 BK4220 Series Blower Kit Installation Operation Manual C436M B 12 94 1 0 WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 2 0 SCOPE The information contained within this manual covers the installation and operation of the BK4000 BK4024 BK4220 Blower Kits Please familiarize yourself with the information in this manual prior to installation and operation 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes 2 1 DESCRIPTION 2 Unless the unit is specifically marked as a NEMA Type 3 6P enclosure it is designed for Indoor use only and it must not be installed where exposed to rain and moisture The BK4000 B K4024 BK4220 Blower Kits are engi neered for installation in the EH4014 and EH4018 En closures The BK4000 requires 120 VAC the BK4024 requires 24 VAC and the BK4220 requires 230 VAC 4 Only use replacement parts recommended by PELCO All units can be used in conjunction with the corre sponding Heater Kit BK4000 requires 4 watts at 120 VAC 60 Hz BK40724 requires 3 watts at 24 VAC 60 Hz CE BK4220 requires 4 8 watts at 230 VAC 60Hz CE NOTE Once installed the blower kit will reduce the maximum camera lens length specified by 1 3 4 inches PELCO 300 W Pontiac Way Clovis CA 93
2. E 2 Screw 6 32 x 1 4 self tapping phil ZH6 SFX 250SPP F 8 Internal tooth lockwasher 6 ZH6LWSIS EH4000 SLED Figure 1 Blower Kit Installation 2 PELCO Manual C436M B 12 94 4 0 WIRING DIAGRAMS The following items are supplied in the blower kits Refer to Figure 2 for wiring information with the use of the heater kit PCB board and without Fan 120 VAC 19 CFM MM750010003 120 amp 230 VAC models Fan 24 VDC 19 CFM ED210005 24 VAC model Resistor for fan 3K ohm RES003 0K10 0 230 VAC model Bridge Rectifier Diode DIOMDA104 24 VAC model Capacitor CAPU0050 0 25 24 VAC model Component Bracket BK7044002COMP 24 amp 230 VAC models Input AC High Input AC High M Input AC neutral Input AC neutral Ground Ground 2 COMNOUNARWNM Thermostat Heater COONODUNSWNhY 24 VAC Model Input AC High Input AC neutral 5 Ground slcblsel Heater Blower wiring diagrams using Heater Kit with PCB Butt Splices Provided CS5 Fan C 120 VAC BK4000 Blower Wiring Installation only 3 Lt PCB not required m 230 VAC BK4220 Resistor Figure 2 Blower Kit Wiring Diagram PELCO Manual C436M B 12 94 3 5 0 WARRANTY AND RETURN INFORMATION WARRANTY PELCO will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment six months on all pan and tilts with auto scan and
3. 612 5699 USA e 800 289 9100 or 1 559 292 1981 FAX 800 289 9150 or 1 559 292 3827 DataFAX 800 289 9108 or 1 559 292 0435 3 0 INSTALLATION 1 Remove the Phillips Head screws from the rear cap and slide the assembly out from the enclosure The BK4000 BK4024 BK4220 Blower Kits are sup plied with the following installation parts 2 Attach the blower assembly to the rear plate using two of the self tapping screws holding the end QTY ITEM cap to the sled 1 Blower 3 Wire according to the wiring diagram in Figure 2 1 Blower Bracket NOTE When used with a heater kit and To install the BK4000 BK4024 BK4220 perform the PCB the blower can be wired into the termi following steps refer to Figure 1 nal block on the PC Board see Figure 2 With the blower kit only the PCB is not necessary 3 1 PARTS LIST Figure 1 Item Qty Description Part Number 1 1 Bracket fan pc board BK40004000COMP 2 1 Bracket component 24VAC 230VAC BK7044002COMP 1 PCB assy term thermott used with heater kit PCB9000300ASSY 3 1 Fan 2 36 inch Sq 120 230 VAC MM750010003 1 Fan 2 36 inch Sq 24VDC ED210005 4 1 Resistor 3k ohm 10w 230 VAC blowerkit only RES003 0K10 0 1 Diode Bridge Rect 1A400PRV 24 VAC only DIOMDA104 5 1 Insulator PC board heater kit only BK400010000 A 4 Washer nylon ZH200X437X62N B 4 Screw 6 32 x 3 8 pan phil SS ZH6 32X 375SPP C 2 Screw 6 32 x 1 5 pan phil SS ZH6 32X1 50SPP D 2 Nut hex 6 32 ZH6 323NUTSH
4. ase include a written explanation with the product when returned Ship freight prepaid to PELCO 300 West Pontiac Way Clovis CA 93612 5699 Method of return shipment shall be the same as method by which the repair item is received by PELCO RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at B00 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair Goods returned for repair or credit should be clearly identified with the assigned CA RA number and freight should be prepaid All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Ship freight prepaid to PELCO 300 West Pontiac Way Clovis CA 93612 5699 PELLO PELCO 300 West Pontiac Way Clovis CA 93612 5699 559 292 1981 800 289 9100 FAX 800 289 9150 or 559 292 3827 DataFAX 800 289 9108 or 559 292 0435 International customers call 1 559 292 1981 or FAX 1 559 348 1120 Product specifications subject to change without notice C436M B PELCO Manual C436M B 12 94
5. medium duty scanners and two years on Legacy Intercept and CM9500 CM8500 Matrix products PELCO will warranty all replacement parts and repairs for 90 days from the date of shipment All goods for warranty work shall be sent freight prepaid to our Clovis California facility Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty PELCO is not liable for any incidental or consequential expenses or liability incurred by the customer as a result of field repair installation or any other reason The above warranty is in lieu of any other expressed or implied warranty condition or guarantee by PELCO of the equipment listed herein PELCO makes no warranties except for intended use and will not be liable for any loss damage or costs arising whether consequential or incidental from the use of said merchandise This warranty gives you specific legal rights You may also have additional rights which are subject to variation from state to state If a warranty repair is required contact PELCO at 800 289 9100 or 559 292 1981 for a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or PELCO invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above ple
Download Pdf Manuals
Related Search
Related Contents
the user manual FRSH500 User`s Manual Sony VF-MPTH Operating Instructions Copyright © All rights reserved.
Failed to retrieve file