1. returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Copyright 2005 Pelco All rights reserved PELLO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1 09001 United States Canada United Kingdom The Netherlands Singapore Spain Scan
2. verify the time and date If your Endura system includes the SM5000 system manager the time and date will be synchronized automatically with the Endura system server later once you complete this recovery process Click Next to continue The workstation restarts automatically The Image Finalization Tasks screen appears From the presets list on the right side of the screen click Field Recovery and then click Go 19 The Activate Windows screen appears There are several ways to activate Windows XP 1 by using Internet Explorer 2 from the Connections tab of the Proxy Server Internet Options screen 3 or by telephone Choose the method that best suits your needs and follow the appropriate instructions below To activate Windows XP by using the Internet a From the Activate Windows screen click Yes let s activate Windows over the Internet now and then click Next b Click No don t want to register now let s just activate Windows and then click Next It is not necessary to register Windows XP Pelco registered the software for you when you purchased the WS5050 workstation c The wizard activates the software and displays the following message You have successfully activated your copy of Windows d Click OK 20 21 22 23 To activate Windows XP for a proxy server a From the Windows Start menu select Control Panel b Double click Internet Options and then open the Connections tab c Unde
3. will still start but is damaged you can follow the first set of steps below If not you must restart the workstation in Recovery Mode manually by following the second set of steps A WARNING Recovering Windows XP with this method will remove any files or applications that are currently installed on the disk drive 1 Z If possible copy any important files from the disk drive to another location on the network to a CD or DVD or to a USB connected storage device before continuing If possible close all running applications Restart the workstation and log in as the WS5050 Administrator NOTE It is not enough to switch users to the WS5050 Administrator You must log out and then log back on as the WS5050 Administrator 3 4 5i Open the WS5050 System Tools and double click the Recovery Mode utility The machine restarts in recovery mode When the Recovery Mode main menu appears select 1 for Restore from HD Image A dialog appears asking if you are sure you want to overwrite the operating system Type Y for Yes and then press Enter to continue Windows XP will be restored automatically from the boot image located on the hard disk Once the process is completed the workstation restarts No further configuration is required when you recover Windows XP from the factory default image that is stored on the hard disk To start the workstation in Recovery Mode manually 1 2 Restart the workstation The Pelco logo screen appe
4. C1677M 7 05 If possible copy any important files from the disk drive to another location on the network to a CD or DVD or to a USB connected storage device before continuing Restart the computer As the first screen is displayed press the Delete key to open the BIOS menu Press the right arrow until you highlight the Boot Sequence tab to open it Press the down arrow to move to the Boot Device Priority list Reorganize the list of devices so that the DVD device appears first in the list Press the F10 key and then press Enter to save the changes and to exit the BIOS With the recovery DVD in the DVD drive restart the computer As the computer starts from this DVD a dialog appears warning you that the hard disk will be overwritten Type Y to confirm that you want to overwrite the disk drive Recovering the operating system might take 15 minutes or more Eject the recovery DVD and then restart the workstation As the workstation restarts press the Delete key to return to the BIOS menu Open the Boot Sequence tab and then press the down arrow to return to the Boot Device Priority list Reorganize the list of devices so that the hard disk appears first in the list Press the F10 key and then press Enter to save your changes Restart the computer The Windows setup dialog opens Enter the Windows license number and then click Next to continue to the Time and Date settings screen Select the correct time zone and
5. PELLO Endura WS5000 Software Recovery Instructions D getice Video Security System C1677M 7 05 This document describes how to restore the WS5000 software or the Windows XP operating system in the event that either of these becomes corrupted The procedures contained in this document will restore the WS5000 software and the Windows XP operating system back to their original factory default settings This document does not include procedures for backing up files or data to alternate storage media J WARNING Under certain circumstances all additional files or software installed on the disk drive will be removed during a recovery process If possible copy any necessary files to another location on the network to a blank CD or DVD or to a USB attached storage device before you start these procedures DETERMINING WHAT TYPE OF FAILURE HAS OCCURRED ON THE WORKSTATION This document provides instructions to restore your workstation to factory default settings if any of the following events occur e The WS5000 software becomes corrupted e The Windows XP operating system becomes corrupted but it will still start e The Windows XP operating system becomes corrupted and it will not start The Windows XP operating system becomes corrupted and you cannot access the boot image Pelco provides several methods for restoring the workstation to full operation To restore only the WS5000 software use the built in Re install WS5000 utili
6. ars When a blinking cursor appears in the upper left hand corner press the Esc key The Extended Operating System Loader screen appears Type R to select PC App Recovery Mode The Enter Password screen appears Enter the password for the WS5050 Administrator and then press Enter The Recovery Mode Main Menu appears Type 1 to restore from the image on the hard disk A dialog appears asking if you are sure you want to overwrite the operating system Type Y to continue Windows XP will be restored automatically from the boot image located on the hard disk Once the process is completed the workstation restarts No further configuration is required when you recover Windows XP from the factory default image that is stored on the hard disk C1677M 7 05 Recovering the System from a Recovery DVD lf the operating system software on the disk drive is so badly damaged that you cannot restore it directly from the drive follow these instructions to restore the operating system from the recovery DVD you received with the WS5050 workstation During this process you will be prompted to enter your Windows license number and your WS5050 workstation serial number The Windows XP license number is located on the back panel of the WS5050 workstation The serial number is located on the front panel of the WS5050 workstation A WARNING Recovering Windows XP with this method removes any files or applications that are currently installed on the disk drive
7. d on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state REVISION HISTORY Manual Date Comments C1677M 7 05 Original version Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts
8. dinavia France Middle East
9. ed or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series ixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The amp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether base
10. letters or numbers Blank spaces hyphens and underlined characters are not allowed This name is used to identify the workstation on the Endura network If you have the original name for the machine use it To leave it blank merely press Enter without entering a name Provide the WS5050 workstation serial number and press Enter This number is located on the front panel of the workstation A summary of your settings is displayed Review the information on this screen and then press Enter to complete the recovery The system restarts automatically and creates a new default boot image This process can take several minutes This new boot image will contain all of the information you entered during the recovery process It will be available for a future recovery process as needed Once the boot image is created the workstation restarts C1677M 7 05 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motoriz
11. r Proxy Server check the box for Use a proxy server for your LAN and then enter the IP address and port number Your system administrator can provide you with this information ick OK twice to close the Connections tab and the Internet Options screen ose the Control Panel and return to the Activate Windows screen ick Read the Windows Product Activation Privacy Statement click Back and then click Next ick No don t want to register now let s just activate Windows and then click Next It is not necessary to register Windows XP elco registered the software for you when you purchased the WS5050 workstation C C f Click Yes let s activate Windows over the Internet now c C Pi The wizard activates the software and displays the following message You have successfully activated your copy of Windows j Click OK To activate Windows by telephone a From the Activate Windows screen click Yes want to telephone a customer service representative to activate Windows now b Click Read the Windows Product Activation Privacy Statement click Back and then click Next c When activation is completed you receive the following message You have successfully activated your copy of Windows d Click OK Once the software is activated return to the DOS window to continue Create a friendly name for the WS5050 workstation and then press Enter This optional name may contain
12. rom the desktop double click the WS5050 System Tools shortcut The WS5050 System Tools folder opens Double click Re install WS5000 A DOS window opens and the utility starts If you have exported video or audio recordings to the WS5050 a list of recordings is displayed You must remove all recordings before the utility will restore the software To avoid losing sensitive or critical recordings copy them to another directory on the hard drive to another directory on the network or to a removable storage device before you delete them a From the WS5050 System Tools folder open the GUI folder b Remove all recordings located with the following extensions pef mp4 bmp jpg joeg and png Most recordings are stored in either the Export folder or the Images folder You might also have stored recordings in other folders under the GUI folder These must also be removed before the utility will continue c Once you remove all recordings return to the DOS window and press any key The utility closes d From the WS5050 System Tools folder double click Re install WS5000 If no more image files are found the utility will restore the WS5000 software Log out and then log back on as a user No further configuration is required C1677M 7 05 Recovering the Windows Operating System from the Boot Image You must restart the workstation in Recovery Mode if you want to restore the operating system from the boot image If Windows
13. ty to restore it on the workstation To restore Windows XP when it is damaged but the workstation will start use the bootable image located on the disk drive to restore Windows XP You can also use the bootable image to restore Windows XP by starting the workstation in Recovery Mode manually In the event that the workstation will not start at all restore the operating system manually with the recovery DVD that you received with your workstation To determine which recovery option you should use answer the following questions e Does the computer start but the WS5000 software will not If so use the Re install WS5000 utility to restore the software Refer to Recovering the WS5000 Software e Does Windows XP start but it is corrupted If so restore Windows XP from the online default boot image Refer to Recovering the Windows Operating System from the Boot Image e Does the workstation fail to start at all If so follow the instructions in Recovering the System from a Recovery DVD C1677M 7 05 Recovering the WS5000 Software Follow these instructions if Microsoft Windows is still operable on the workstation but the WS5000 software fails to start properly i If you are logged on as a user close all programs and log out NOTE It is not enough to switch users to the WS5050 Administrator You must log out and then log back on as the WS5050 Administrator Z 3 6 Log on to the WS5050 workstation as the WS5050 Administrator F