Home
Pelco BB08 User's Manual
Contents
1. eene 19 BB08E120 and 08 211 Dimension Drawing 19 LIST OF TABLES Table Video Coaxial Cable Requirements 7 24 VAC Wiring DIStaNC S enceinte tratte hen ricis adf BB08A120 Back Box Exploded Assembly Parts List Figure 4 15 BB08E120 and BB08E211 Back Boxes Exploded Assembly Parts List Figure 5 4 nnne Back Plate Exploded Assembly Parts List REVISION HISTORY Manual Date Comments C456M C456M C456M C456M A C456M B C456M C C456M D 6 93 Original manual 9 93 Addendum incorporated into manual to include updated wiring diagrams as well as updated exploded view diagram 8 94 Manual revised to include updated wiring information 6 95 Manual revised to include BOM quantity changes as per ECO 94 445 incorporated information on E type white finish available as per 95 013 included front label information into BOM as per 94 192 also created manual history and updated to new manual style 6 95 Addendum Incorporated new fuse and fuse holder into wiring diagrams and exploded view diagram as per ECO 95 063 9 95 Manual revised to include sound quieting inserts as standard feature as per ECO 95 356 Made BOM changes as per ECO 95 352 4 96 Added Figure 16 and revised instructions for installing optional backup plate per 96 061 Changed
2. FACEPLATE 8 To create an opening for the wiring use a hammer and punch to remove one of the knockouts in the top of the back box If it is necessary to work inside the back box remove the trim ring and dome by inserting a screwdriver or your fingers between the trim ring and the faceplate and popping the trim ring and dome loose Remove the trim ring and dome see step 3 Remove the parts bag inside the back box Reattach the trim ring and dome to the back box Angle the back box through the grid opening and set the back box into the grid From an opening in a grid adjacent to the back box install the four T rail clips that are supplied in the parts bag refer to Figure 1 If additional support is required such as anchoring with a chain or steel cable to a support beam above the dome enclosure install one or both of the 1 4 20 eye bolts and washers that are supplied in the parts bag a Remove one or two of the 1 4 20 screws in the top of the back box b Screw a nut about a half inch onto an eyebolt c Slide a split lock washer and flat washer onto the eyebolt d Screw the eyebolt into the back box and lock the eyebolt into place by tightening the nut with an 11 mm wrench e Repeat steps b d if you are going to install the second eyebolt f Use a chain or cable to fasten the eyebolt s to a support structure in the ceiling Remove the trim ring and dome Refer to Figure 2 for the following steps
3. 9 10 11 Push the wiring into the back box If you are using conduit fasten the conduit to the back box Install the coaxial cable to the BNC connector Install power to the 10 position terminal block Make sure the power switch on the side of the back box is off I BAR Figure 1 T Bar Clip Installation Pelco Manual C456M D 1 98 1 4 BLACK CONTROLLER 2 MONITOR He COAX AUX J13 ON WHT BLK RXD TDA WHTIBHN DOME DRIVE TXD WHT ORG ALRM BLUE 24 24 NEUTRAL E our e ATF 18 BROWN POWER SWITCH i m o Figure 2 24 VAC Back Box Wiring Diagram Pelco Manual 456 1 98 9 Ji P13 BROWN 4 CONNECT TO e 2 AUX TXD TXD ALRM TO J13 ON DOME DRIVE WHT BLK WHT BRN WHT RED WHT ORG ON Og AC BHE AC 24 VAC POWER SWITCH Figure 3 120 VAC Back Box Wiring Diagram 10 Pelco Manual C456M D 1 98 12 13 If you are not using Coaxitron control connect the control wiring to RXD and RXD From controller To 4 wire terminal inside back box TXD RXD TXD RXD Back box installation is now complete Proceed with the installation of the dome drive unit Refer to the manual provided with the dome drive for further instal lation instructions 3 2 PENDANT NOTE The length of pipe may cause noticeable motion on the video
4. Thermostatically controlled activates ON at 40 F 4 4 C and OFF at 60 F 15 56 C Power Cord Not supplied use 3 wire grounded 18 Awg minimum for 120 VAC supply input Power Cable Not supplied must conform to local and national electrical codes GENERAL Enclosure Environment Indoor or outdoor depending on model ordered Dimensions See Figures 7 and 8 Construction Back box Aluminum Cap Aluminum Bezel Aluminum Trim Ring ABS aluminum Finish Qutdoor BBO8E211 Light gray Indoor BB08A120 White back box and eggshell white face plate trim ring and bezel 08 120 Indoor Models 32 to 120 F 0 to 48 89 C Outdoor Models 10 to 120 F 23 33 to 48 89 C Design and product specifications subject to change without notice This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment 18 Pelco Manual C456M D 1 98 4 25 10 79 28 50 21 59 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 7 BB08A120 Dimension Drawings 16 25 41 27 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 8 BB08E120 and 08 211 Dimension Drawing Pelco Manual C456M D 1 98 19 6
5. unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Please thoroughly familiarize yourself with the information in this manual prior to installation and operation Pelco Manual C456M D 1 98 3 1 2 UNPACKING INSTRUCTIONS Unpack and inspect all parts carefully Be sure to save the shipping carton and any inserts They are the safest material in which to make future shipments If an item appears to have been damaged in shipment replace it properly in its carton and contact the factory at 1 800 289 9100 or 1 559 292 1981 for a replace ment International customers fax 1 559 348 1120 for authorization and instruc tions If an item needs to be returned to the factory for repair consult the WARRANTY AND RETURN section of this manual for instructions The following items are supplied BB08A120 MODEL 1 Back box with face plate trim ring and dome 1 Parts bag 2 Eye bolts with nuts flat washers and split lock washers 4 clips 1 Installation Operation Manual C456M D BBOS8E120 and BBOSE211 MODELS Bezel with dome Pendant cap Back box Parts bag with two O rings BBO8E211 only Installation Operation Manual C456M D uu pep 1 3 RECOMMENDED TOOLS Pelco does not supply basic tools needed for the installation process The following tools are re
6. O Pelco Manual 456 1 98 Black bezel assembly with smoked dome Light gray bezel assembly with clear dome Back box textured black Back box light gray Pendant cap black Pendant cap light gray Pin bezel attachment Nylon spacer flanged Compression spring Flange 1 1 2 NPT Gasket BB08E211 only O ring BB08E211 only Safety cable Rocker switch On Off not shown Screw 1 4 20 x 5 8 flat head Phillips Allen screw 6 32 x 1 4 SQP0810000ASSY SQP0810011ASSY 8084195BCOMP 8084195GCOMP 8084994COMP 8084894COMP 8004053COMP SPA3109 SPRG10000 MRCA4000COMP 80010198 80010010 E7081002COMP SW10201S11N41P ZH1 420X 625SFS ZH6 32X 250SS 15 Figure 6 Back Plate Exploded Assembly Diagram 16 Pelco Manual C456M D 1 98 Table Back Plate Exploded Assembly Parts List o N OOA WN 2 gt Pelco Manual C456M D 1 98 2 2 2 1 1 2 1 2 1 1 3 1 1 2 2 2 1 6 1 1 1 1 1 1 1 1 A A BR o FMNM FPO HM LH PH PL Latch backup plate Latch Latch bracket Transformer 120 VAC model only 25 position connector plug Screw 6 32 10 position terminal block Alignment pin Heater fan mounting bracket Fan 120 VAC Heater 120 VAC Back plate Connector mounting bracket Stabilizer bracket Boot Hairpin clip Connector BNC jack insulated 2 position jumper 10 position terminal block cover Thermostat units with heaters and blower 4 position
7. heater specifications 1 98 Completely revised manual to reduce the number of models and expand installation instructions Incorporated ECO 97 364 Updated exploded assembly diagrams and parts lists Changed manual to new format and manual pagination Pelco Manual C456M D 1 98 1 0 GENERAL 1 1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes 2 Unless the unit is specifically marked as a NEMA Type 3 38 4 4X 6 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 3 Only use replacement parts recommended by Pelco 4 After replacement repair of this unit s electrical components conduct a resis tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry 5 The installation method and materials should be capable of supporting four 4 times the weight of the enclosure pan tilt camera and lens combination The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this
8. scanners or presetlenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating tothe Products shall not exceed the price paid by the Dealerto Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco i
9. terminal block Fuse holder Fuse 2A 3AG not shown Capacitor 47 uF 12 V not shown Capacitor 220 uF 100 V not shown Capacitor 270 uF 100 V not shown Screw 10 32 x 1 2 flat head Phillips Split lock washer 1 4 Nut 1 4 20 Spacer 312 OD x 1 8 long 10 Internal star washer 10 Screw 10 32 x 1 pan head Phillips Nut 6 32 Screw 6 32 x 3 8 pan head Phillips Screw 6 32 x 2 pan head Phillips Spacer 3 16 hex by 3 4 long 2 56 tapped Screw 10 32 x 1 2 pan head Phillips Spacer 1 4 hex by 1 2 long 6 32 tapped Screw 6 32 x 5 8 flat head Phillips Screw 6 32 x 1 2 pan head Phillips 8004244COMP 8004105COMP 8004143COMP TRF21243 30 70F CON10P025Z41T ZH208211 4 TRB6TBV 10 OE 8004402COMP 8004118 EH4600115W3 HTR50120 8004190COMP 8004046COMP 8004047COMP 80010007 ZH1 4CLIPSS 1 0022415 TRBJ6 2 TRBTC6 10 PFH EH5510049A TRB4 140 FUS357001 FUS2 CAPE474P012MAY CAPF221P100JRN CAPF271P100JRN ZH10 32X 500CFS ZH1 4LWSSL ZH1 4 20NUTCH SPA8540 ZH10LWSIS ZH10 32X1 00SPP ZH6 32NUTSH ZH6 32X 375SPP ZH6 32X2 00SPS SPA9401L ZH10 32X 500SPP SPA8423 ZH6 32X 625SFS ZH6 32X 500SPP 17 5 0 SPECIFICATIONS ELECTRICAL Enclosure Back Box Input Voltage 24 VAC or 120 VAC Power Requirements Receiver Driver 48 vA for 24 VAC and 120 VAC dome drives Blower continuous duty One 1 at 33 cfm 6 7 watts 120 VAC 60 Hz Heaters 120 VAC 135 watts total
10. 0 Fax 650 737 0933 Pelco Manual C456M D 1 98
11. 0 WARRANTY AND RETURN INFORMATION Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Copyright 1998 Pelco All rights reserved 20 WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FT FR8000 Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Sixmonthsonall pan andtilts
12. BBOS Series Intercept Back Box Installation Operation Manual C456M D 1 98 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 CONTENTS Section Page GENERAL tut risate eevtete iria kiere vale satu to be ee 3 1 4 IMPORTANT SAFEGUARDS AND WARNINGS 3 1 2 UNPACKING INSTRUCTIONS 4 1 8 RECOMMENDED TOOLS wid 2 0 DESCRIPTION 5 2 1 MODELS 5 3 0 INSTALLATION mu 3 1 SUSPENDED CEILING 20 3 2 RENDANT deiecta eter a teme ELE es Ei 11 4 0 EXPLODED ASSEMBLY 13 SPECIFICATIONS 18 6 0 WARRANTY AND RETURN 20 LIST OF ILLUSTRATIONS Fi T Bar Clip Installation ier rrr 24 VAC Back Box Wiring Diagram 120 VAC Back Box Wiring BB08A120 Back Box Exploded Assembly Diagram 18 BBO8E120 and BB08E211 Back Boxes Exploded Assembly Diagram 14 Back Plate Exploded Assembly 16 BB08A120 Dimension Drawings
13. commended Medium Phillips screwdriver Wire cutter Wire stripper BNC crimp tool Coaxial cable stripper Hammer and punch suspended ceiling model only Large Phillips screwdriver suspended ceiling model only 11 mm wrench suspended ceiling model only Pelco Manual C456M D 1 98 2 0 DESCRIPTION The BBO8 Series of back boxes is part of the 10508 Intercept Series of domes The 10508 Series is an integral system that includes a back box 8 dome drive 0008 dome receiver driver DRDO8 and imager optics package IOP08 This manual covers the BBO8 Series of back boxes For installation and operation instructions for the dome drive refer to manual C416M C for the dome receiver driver refer to CA66M E and for the imager optics package refer to C1441M C 2 1 MODELS BB08A120 Indoor back box with smoked dome 24 VAC input installs in a suspended ceiling CE UL 08 120 Indoor black pendant mount back box with smoked dome 24 VAC input BBO8E211 Outdoor light gray pendant mount back box with clear dome 120 VAC input Includes heater and fan UL Pelco Manual C456M D 1 98 5 3 0 INSTALLATION 3 1 SUSPENDED CEILING 1 Remove the ceiling tile from the ceiling If you are installing the back box into a 2 x 4 61 x 122 cm ceiling grid cut the tile in half and install an additional T bar for support Reinstall one of the 2 x 2 61 x 61 cm sections 2 Bring the wiring to th
14. dis play If this occurs additional support of the pipe by bracing guy wiring etc will be required Pelco Manual C456M D 1 98 1 9 10 Install the pendant dome mount Refer to the instructions supplied with the mount The back box is designed to be suspended from a suitable length of 1 1 2 NPT pipe threaded at both ends For outdoor model apply pipe thread sealant to the pipe before assembly Install one end of the pipe into the mount Tighten to approximately 30 ft lb and tighten any locking means that may be provided on the mount Bring the wiring for the back box through the mount Video Refer to Table for the type of video coaxial cable to use Power If the input power to the dome is 24 refer to Table to determine the size of wire to use For the 120 VAC model make sure the wiring can supply power for the heaters and fan as well as the receiver driver Refer to Section 5 0 SPECIFICATIONS for power requirements Control If you are using a Coaxitron controller the control signals to operate the dome drive will be transmitted over the video coax If you are not using a Coaxitron controller bring wires to the back box for two RS 485 control lines RX and RX Remove the parts bag inside the back box Outdoor Model Only Place an O ring onto the back box mounting pipe Push the O ring up about 4 inches 10 cm or as far as it will go if the pipe is not 4 inches long Outdoo
15. e back box opening in the ceiling Video Refer to Table for the type of video coaxial cable to use Power If the input power to the dome is 24 refer to Table to determine the size of wire to use The power requirement is 48 vA Control If you are using a Coaxitron controller the control signals to operate the dome drive will be transmitted over the video coax If you are not using a Coaxitron controller bring wires to the back box for two RS 485 control lines RX and RX 6 Pelco Manual C456M D 1 98 Table A Video Coaxial Cable Requirements RG59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Minimum cable requirements 75 ohms All copper center conductor All copper braided shield with 95 braid coverage Table B 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications andare calculated with a 10 percent voltage drop 10 percent is generally the maxi mum allowable voltage drop for AC powered devices EXAMPLE An enclosure that re Wire Gauge quires 80 vA and is installed 35 feet 20 18 16 14 12 10 10 m from the transformer would 10 283 451 716 1142 1811 2880 require a minimum wire gauge of 20 86 137 218 348 551 877 Awg 20 141 225 358 571 905 1440 42 68 109 174 275 438 NOTE Distances are calculated in 30 94 150 238 380 603 960 feet value
16. nstalled The back box installation is now complete Proceed with the installation of the dome drive unit Refer to the manual provided with the dome drive for further installation instructions Pelco Manual C456M D 1 98 4 0 EXPLODED ASSEMBLY DIAGRAMS Figure 4 BB08A120 Back Box Exploded Assembly Diagram Pelco Manual C456M D 1 98 13 Figure 5 BBO8E120 and 8 11 Back Boxes Exploded Assembly Diagram 14 Pelco Manual C456M D 1 98 Table BB08A120 Back Box Exploded Assembly Parts List Figure 4 Quantity Description Part Number RA a k ee a Trim ring white Dome seal not shown Fixed dome smoked not shown Sound quieting ring not shown Back box Face plate drop ceiling white Gland plate Ball stud receiver T rail retaining clip Back box foam insert Back box foam insert Rocker switch On Off not shown Screw 1 4 20 x 3 8 pan head Phillips Split lock washer 1 4 Nut 6 32 Internal star washer 6 Eye bolt 1 4 20 x 2 Nut 1 4 20 8082ASSY 80810007 80810008 4 8083001 8084297COMP 8084167COMP 8004130COMP 90010030 80010008 8083000 1 8083000 SW10201S11N41P ZH1 420X 375SPP ZH1 4LWSSL ZH6 32NUTSH ZH6LWSIS ZH1 4 20X2 0EYE ZH1 4 20NUTCH Table D BB08E120 and BBO8E211 Back Boxes Exploded Assembly Parts List Figure 5 Quantity Description Part Number 4 5 6 7 8 9 9 09 0 ak ak
17. nvoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 6 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 170
18. r Model Only Install the pendant cap on the pipe and place the top side of the cap against the O ring Place the second O ring onto the pipe and push the O ring against the bottom side of the pendant cap Back out the lock screw on the mounting flange of the back box so that the back box can be screwed onto the mounting pipe Indoor Model Only Place the pendant cap on top of the back box Screw the back box onto the mounting pipe Tighten the lock screw Outdoor Model Only Push the pendant cap down against the top of the back box Push the top O ring against the top of the pendant cap Refer to Figure 3 for the following steps 11 12 Install the coaxial cable to the BNC connector Install power to the 10 position terminal block Make sure the power switch on the side of the back box is off 11 12 13 14 15 If you are not using Coaxitron control connect the control wiring to RXD and RXD From controller To 4 wire terminal inside back box TXD RXD TXD RXD The bezel and dome assembly can be attached to the back box at this time or it can be done after the dome drive is installed To install the dome drive refer to the manual provided with the dome drive To attach the bezel and dome assembly to the back box clip the safety cable inside the bezel to the bracket just below the power switch inside the back box Let the bezel and dome assembly hang from the back box until the dome drive is i
19. s in parentheses are 28 45 72 115 183 292 meters 40 70 112 179 285 452 720 21 34 54 86 137 219 50 56 90 143 228 362 576 17 27 43 69 110 175 60 47 75 119 190 301 480 14 22 36 57 91 146 70 40 64 102 163 258 411 12 19 31 49 78 125 80 35 56 89 142 226 360 10 17 27 43 68 109 90 31 50 79 126 201 320 9 15 24 38 61 97 100 28 45 71 114 181 288 8 13 21 34 55 87 110 25 41 65 103 164 261 7 12 19 31 49 79 120 23 37 59 95 150 240 7 11 17 28 45 73 130 21 34 55 87 139 221 6 10 16 26 42 67 140 20 32 51 81 129 205 6 9 15 24 39 62 150 18 30 47 76 120 192 5 9 14 23 36 58 160 17 28 44 71 113 180 5 8 13 21 34 54 170 16 26 42 67 106 169 4 7 12 20 32 51 180 15 25 39 63 100 160 4 7 11 19 30 48 190 14 23 37 60 95 151 4 7 11 18 28 46 2001 14 22 35 57 90 144 4 6 10 17 27 43 Total vA consumed Maximum distance from transformer to load Pelco Manual C456M D 1 98 7