Home

Patton electronic ENVIRONET EHA3201 User's Manual

image

Contents

1. C O Compliance Information C 1 Compliance EMC e FCC Part 15 Class A EN55022 Class A EN55024 Safety UL 60950 1 CSA C22 2 NO 60950 1 EC EN60950 1 AS NZS 60950 1 PSTN Regulatory FCC Part 68 5 03 AS ACIF 043 2003 C 2 FCC Part 68 ACTA Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AMEQZZTXXXX If requested this number must be provided to the telephone company The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA If this equipment causes harm to the telephone network the telephone company vill notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone com pany will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced wi
2. Resistance Insulation Resistance AC Breakdown Voltage Operating Temperature Range Approvals Mechanical Sealing Cable Acceptance Contact Accommodation Termination Insertion Withrawal Force No poles Insertion Force typ Withdrawal Force typ Cable Retention force Dimensions Overall dimensions of connectors when mated together Flex Flex In Line Dia over coupling ring Material Body Mouldings Flammibilty Rating UV Resistance Contacts O Rings Chassis Sealing O Ring RoHS 16 gt 10 MQ 500V a c IP68 EN 60529 2 3 pole 20 24 AWG 4 6 8 pole 22 26 AWG 10 12 pole 24 28 AWG Crimp solder and PCB 19N 25N 27N 27N 28N 55N 62N 22N 25N 29N To EN 50021 1999 Copper alloy Gold plated EHA3201 Quick Start Guide
3. entrance A sprinkler system pipe A cold water pipe Building structural steel 2 Install the grounding wire between the grounding stud see Figure 1 on page 3 and the grounding source 1 2 Connecting the Twisted Pair Line Interface To function properly the G SHDSL Router must be connected using twisted pair unconditioned dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable The G SHDSL Router is equipped with an RJ 45 interface jack Line which is a two wire interface Observe the signal pin relationships on the G SHDSL Router s Line interface jack The signal pin relationship is shown in figure 2 1 no connection 2 no connection 3 no connection 4 2 Wire RING 5 2 Wire TIP 6 no connection 7 no connection 8 no connection Figure 2 EnviroNET G SHDSL Router RJ 45 twisted pair line interface 1 3 Connecting the 10 100Base T Ethernet Interface The G SHDSL Router has an unshielded RJ 45 auto MDIX10 100Base T interface This port is designed to con nect directly to a 10 100Base T network figure 3 shows the signal pin relationships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long 4 EHA3201 Quick Start Guide 1 TX data output from the G SHDSL router P 2 TX data output from the G SHDSL router 2 7 8 RX data input to the G SHDSL
4. pages 32 38 in the Model 3201 amp 3241 User Manual Fora routed application connecting the CPE to a DSLAM see pages 46 77 in the Model 3201 amp 3241 User Manual 3 0 Additional Information Refer to the Model 3201 amp 3241 User Manual located on the CD ROM shipped with your EHA3201 and available online at www patton com manuals for detailed information about Installing configuring operating and troubleshooting e Warranty trademark amp compliance A O Customer and Technical Support Toll Free VolP support call sip support patton com with a VolP SIP phone Online support www patton com E mail support support patton com answered within 1 business day Telephone support Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST 1300 to 2200 UTC GMT Alternate 41 0 31 985 25 55 Switzerland Monday Friday 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland EHA3201 Quick Start Guide 7 B O EHA Case Specifications UAC 110 220VAC 2 25W B 2 Temperature Range 40 185 F 40 85 B 3 Humidity Upto 90 non condensing B 4 Dimensions B H x 9 25 W x 3 25 D B 5 Weight 6 4lb 2 9kg Note For Model 3201 unit specifications refer to the Model 3201 amp 3241 User Manual located on the CD ROM shipped with your EHA3201 and available online at www patton com manuals EHA3201 Quick Start Guide
5. router A aa no connection 5 5 no connection 6 RX data input to the G SHDSL router 8 S 7 no connection 8 no connection Figure 3 EnviroNET G SHDSL Router 10 100Base T RJ 45 Connector Pinout 1 4 Connecting Power The EHA3201 is an internally powered unit The power connection is made via the 3 pin power connector on the bottom panel of the EnviroNET G SHDSL Router A mating connector is provided to create the mating cable see figure 4 No configuration is necessary for the power supply EHA3201 R UI R LM E L Line N Neutral E Earth L 4 24 N Ground EHA3201 R 24 Figure 4 Connecting the power cable The EnviroNET G SHDSL Router does not have a power switch so it powers up as soon as it is plugged in Router Fuse replacement should only be performed by qualified service personnel Contact Patton Electronics Technical support at WARNING 301 975 1007 for more information f There are no user serviceable parts in the EnviroNET G SHDSL EHA3201 Quick Start Guide 5 Note It does not matter whether the positive or negative side of the DC power supply is grounded However the polarity on the power source must be matched up properly to the EHA3201 power input i e negative power source terminal to negative power input positive power source terminal to positive power input 2 0 Configuring the EHA3201 The EnviroNET G SHDSL Router comes pre configured to communicate wit
6. wire end into contacts crimp or solder to secure wire Note When using crimp contacts ensure correct positioner is used in the crimp tool 0 Positioner Crimp Tool amp Positioners Part No Contacts Colour 14025 1AMP 1A Green 14025 5AMP 5A Red 14025 8AMP 8A Blue 14025 Crimp Tool ou E e cus or Solder Contacts 4 Assemble contacts in to the Carrier Housing ensuring they are in the correct location and pushed fully home A contact insertion extraction tool is available Part No 13027 1 amp Part No 13027 1 5 amp Part No 13027 2 8 amp Pin identification Sockets viewed from cable side Plugs viewed from cable side 5 Check the internal O Ring is in place and correctly seated Bring the Body Moulding down the cable and snap firmly over the carrier moulding ensuring that the steps on the blue Carrier Housing are aligned with the apertures in the Body Moulding and that the sealing cap strap is not over the blue Carrier Housing Note once the Body Moulding is snapped over it cannot be removed 6 Bring the Gland and Collet down the cable and locate in the Body Moulding Screw the Clamp Nut onto the body moulding and tighten as close to the shoulder as possible If the Sealing Cap Assembly is being used slide over the Body Assembly and locate over the shoulder of the Body Moulding EHA3201 Quick Start Guide 15 SPECIFICATION Electrical Poles Current Rating Voltage Rating Contact
7. emperature flammabil ity and mechanical serviceability e WAN LAN amp PSTN ports connections may have hazardous voltages present regardless of whether the device is powered ON or OFF PSTN relates to interfaces such as telephone lines FXS FXO DSL xDSL TI E1 ISDN Voice etc These are known as hazardous net work voltages and to avoid electric shock use caution when working near these ports When disconnecting cables for these ports detach the far end connection first Do not work on the device or connect or disconnect cables during peri ods of lightning activity When the EHA3201 is mounted it shall be secured in such a way as to withstand a vertical shear force of 90N or 20lbs WARNING z In accordance with the requirements of council directive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling EHA3201 Quick Start Guide Electrostatic Discharge ESD can damage equipment and impair electrical IN circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the follow WARNING ing to prevent ESD e Always follow ESD prevention procedures when removing and replac ing cards e Wear an ESD preventive wrist strap ensuring that it makes good skin contact Connect t
8. ertified connector assembly telephone extension cord The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the ground connections of the power utility telephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas C 4 Radio and TV Interference FCC Part 15 This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television recep tion This equipment has been tested and found to comply with the limits for a Class A computing device in accor dance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be determined by disconnec
9. f Patton Electronics Company All other trademarks presented in this docu ment are the property of their respective owners Warranty Trademark amp Compliance Information For warranty trademark and compliance information refer to the Model 3201 amp 3241 User Manual located on the CD ROM that came with your router or available online at www patton com 12 EHA3201 Quick Start Guide D O Buccaneer 400 Series Environmentally Sealed Connectors A The following instructions are provided by Bulgin UK for assembling the 400 Series Buccaneer IP68 Sealed Electrical IMPORTANT Cable Connectors 400 Series Buccaneer IP68 Sealed Electrical Cable Connectors Wiring and Assembly Instructions BIBULGIN www bulgin co uk Caution Not for interrupting current Attention Ne pas utiliser pour couper le courant IMPORTANT SAFETY NOTICE N For your protection all mains 250V equipment used out of doors in damp or wet conditions should be supplied from a correctly fused source and protected by an approved R C D to BS7071 BS7288 BS4293 BS EN 61008 1 BS EN 1008 2 2 IF IN DOUBT SEEK ADVICE Mains Wire Connections Important connect wires Brown to terminal L Blue to terminal N Green Yellow to terminal E amp Plug Socket Leaflet No 14072 Iss No 3 EHA3201 Quick Start Guide 13 IMPORTANT PLEASE READ INSTRUCTIONS PRIOR TO ASSEMBLY Before using the connector it is important that these ins
10. h other devices on the network To futher configure the EHA3201 you may log into the web management system 2 1 Connect to a PC Connect the EHA3201 s Data port to your PC see figure 5 The PC used for configuring the EHA3201 should be set for DHCP client Connect the EHA3201 to a power source to turn on the unit The EHA3201 Data port uses the DHCP client to automatically assign an IP address and netmask The EHA3201 will send the IP address to the PC Enter the EHA3201 s IP address in the address bar of the web browser 6 Login and perform any desired configuration changes through the EHA3201 s web browser interface A O No Un Figure 5 Connecting the EHA3201 to the local IP network For information on changing the IP address refer to Chapter 3 Quick Start Installation in the Model 3201 amp 3241 User Manual 6 EHA3201 Quick Start Guide 2 2 Configuring applications The EHA3201 is typically used in a bridged or routed application For instruction on how to configure the EHA3201 for an application refer to the Model 3201 amp 3241 User Manual Bridged Applications For a bridged application connecting standalone units back to back see pages 29 32 in the Model 3201 amp 3241 User Manual e For a bridged application connecting the CPE to a DSLAM see pages 38 46 in the Model 3201 amp 3241 User Manual Routed Applications For a routed application connecting standalone units back to back see
11. he clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground To properly guard against ESD damage and shocks the wrist strap and cord must operate effectively If no wrist strap is available ground yourself by touching the metal part of the chassis 1 0 Installing the EHA3201 To install the EHA3201 follow these steps 1 Make a ground connection for the unit refer to section 1 1 Grounding the EHA3201 on page 4 2 Connect the line interface between the units refer to section 1 2 Connecting the Twisted Pair Line Inter face on page 4 Note See figure 1 for the EHA3201 unit s bottom panel arrangements 3 Connect the Ethernet interface refer to section 1 3 Connecting the 10 100Base T Ethernet Interface on page 4 4 Connect the power plug refer to section 1 4 Connecting Power on page 5 EnviroNET PLE EHA3201 a Ethernet port Line twisted pair RJ 45 interface Power Grounding Stud Figure 1 EHA3201 Bottom Panel EHA3201 Quick Start Guide 3 1 1 Grounding the EHA3201 Before installing the EnviroNET G SHDSL Router it is important to establish a good grounding connection first 1 Assemble a ground wire using 10 AWG wire with green and yellow colored insulation and two ring ter minals Make the wire long enough to reach one of the following earth ground sources The building ground rod generally located at the site s main service
12. pa PATTON Ba Electronics To Model EHA3201 EnviroNET G SHDSL Router Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment It is not C intended nor approved for use in an industrial or residential environment Sales Office 1 301 975 1000 Part Number O7MEHA3201 QS Rev B Technical Support 1 301 975 1007 Revised July 21 2011 E mail support patton com WWW www patton com A WARNING A Do not open the device when the power cord is connected For sys tems without a power switch and without an external power adapter line voltages are present within the device when the power cord is connected For devices with an external power adapter the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker in compli ance with local regulatory requirements For AC powered devices ensure that the power cable used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 amp GND or Hot Neutral amp Safety Protective Ground the wall outlet or socket must have an earth ground For DC powered devices ensure that the interconnecting cables are rated for proper voltage current anticipated t
13. th this equipment for repair or warranty information please contact our company If the equipment is causing harm to the telephone network the telephone company may request that you discon nect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility commission public ser vice commission or corporation commission for information EHA3201 Quick Start Guide 9 3 3 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is con firmed by the registration number The abbreviation IC before the registration number signifies that registra tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment This Declaration of Conformity means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a c
14. ting the cables try to correct the interference by one or more of the fol lowing measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 10 EHA3201 Quick Start Guide C 5 EC Declaration of Conformity Product Description Models 3201 amp 3241 We certify that the apparatus identified above conforms to the requirements of Council Directive 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equip ment and the mutual recognition of their conformity conformity to the above directive is indicated by the CE sign on the device C The safety advises in the documentation accompanying the products shall be obeyed The The signed Declaration of Conformity can be downloaded from www patton com certifications C 6 Authorized European Representative DRM Green European Compliance Services Limited Oakdene House Oak Road Watchfield Swindon Wilts SN6 8TD UK EHA3201 Quick Start Guide 11 Copyright statement Copyright 2011 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors that may appear in this document Trademarks statement The term EnviroNETis a trademark o
15. tructions are carefully read and understood to ensure the connector system is completely water tight and electrically safe IF IN DOUBT PLEASE CONSULT A QUALIFIED ELECTRICIAN Body Moulding The body moulding is a snap fit assembly This is a once only fit to be completed after the connector has been wired Do not snap on before wiring is complete Cable Glands To ensure the correct cable sealing pairs of cable glands and collets are available to accurately fit cable diameters from 3 0 up to 7 0mm in 0 5mm steps It is important to match the correct gland and collet to the cable used these are Cable diameter Gland Collet Colour Cable diameter Gland Collet Colour 3 0 3 5mm Light Grey 5 0 5 5mm Yellow 3 5 4 0mm Grey 5 5 6 0mm Blue 4 0 4 5mm Green 6 0 6 5mm White B19 1 19 2 4 5 5 0mm Red 6 5 7 0mm Black i Panel cut out details for PX0413 ASSEMBLY WIRING INSTRUCTIONS 1 Thread the Clamp Nut Collet Gland and Body Moulding on to the cable Also thread on the sealing cap retaining straps if using sealing caps with the flex connectors Note When using Flex Connector PX0410 also check the locking ring is fitted over the Carrier Housing this is a one piece moulding on the In line Flex Connector PX041 1 Locking Ring Carrier Housing 2 Strip and prepare cable Note Do not exceed stripping length as this can effect the cable sealing 14 EHA3201 Quick Start Guide Crimp Tool 3 Insert bared