Patton electronic CopperLINK 2158B User's Manual
Contents
1. Push toggle up for ON position CO Push toggle E E down for OFF position 1234 Figure 6 DIP switch orientation 4 2 CONFIGURING DIP SWITCH S1 DIP switch S1 is where you configure the CopperLINK line The following table describes the configuration for the 2158B Table 1 2158B Firmware Configuration Master Slave ON Slave Fast 6dB 10 10 C pes OFF Master Interleave 9dB 10 10 CO S1 2 Impulse Noise Protection e Fast Mode Direct data transmission with latency less than 1ms Interleave Mode Provides data transmission protection for up to 250 ms impulse noise with latency less than 6 ms S1 3 General Protection Signal to Noise Ratio 6dB Original line noise protection with 6dB SNR e 9dB Better line noise protection with SNR up to 9dB 5 0 OPERATION Once the Model 2158Bs are properly installed they should operate transparently No user settings required This section describes reading the LED status monitors 5 1 POWER UP Before applying power to the Model 2158B please review section 3 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source 5 2 FRONT PANEL LED STATUS MONITORS The Model 2158B features six front panel LEDs that monitor power the Ethernet signals the CopperLINK connection and the remote local set ting Figure 7 shows the front panel location of each LED Table 2 on page 15 describes t
2. 1 6 SAFETY WHEN WORKING WITH ELECTRICITY A WARNING e This device contains no user serviceable parts This device can only be repaired by qualified service person nel e Do not open the device when the power cord is con nected For systems without a power switch and without an external power adapter line voltages are present within the device when the power cord is connected e For devices with an external power adapter the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker in com pliance with local regulatory requirements e For AC powered devices ensure that the power cable used meets all applicable standards for the country in which it is to be installed e For AC powered devices which have 3 conductor power plugs L1 L2 amp GND or Hot Neutral amp Safety Protective Ground the wall outlet or socket must have an earth ground e For DC powered devices ensure that the interconnect ing cables are rated for proper voltage current antici pated temperature flammability and mechanical serviceability e WAN LAN amp PSTN ports connections may have haz ardous voltages present regardless of whether the device is powered ON or OFF PSTN relates to inter faces such as telephone lines FXS FXO DSL xDSL T1 E1 ISDN Voice etc These ar
3. USER MANUAL MODEL 2158B CopperLINK Ethernet Extender m This is a Class A device and is intended for use in a C light industrial commercial environment only It is not intended nor approved for use in a heavy industrial or residential environment PE PATTON Hs Tlecironicsto Part 07M2158B UM SALES OFFICE Rev A 301 975 1000 Revised 4 8 10 TECHNICAL SUPPORT 301 975 1007 An ISO 9001 Certified Company CONTENTS A A 2 A 3 A 4 A 5 A 6 A 8 C 1 C 2 Warranty INfOrmation 2 225 10065 aa 4 Regulatory Information Us 4 EMG Directive iudei is ool same de adea das Pee tees detta ce ee Pisa alan 4 Low Voltage Direcive Safety 4 Radio and TV Interference FCC Part 15 4 CE Declaration of Conformity eee 5 Authorized European Representative 5 NV IC Carrot E 5 Safety When Working With Electricity 6 General INfOrmatiOn cccccssseseeesseeneeeseesseeseeeneeeeeenseeesoneneenens 8 FEAU S ster CHE 8 DESCHPUON seua sairia Re RS 8 INStAN ALON ED M 9 Connecting the Twisted Pair Line Interface 10 Connecting the 10 100Base T Ethernet Interface 11 Connecting POWOL dodici eme cath das 12 COnTIQUIFATION RT 12 Configuring the hardware DIP switches 12 Contiguring DIP SWItCh Sl inire Siete nt ake 14 Operalla seo
4. 58H x 4 16W x 3 75D in 10 6H x 4 1W x 8 8D cm APPENDIX B MODEL 2158B SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES Base Models No power supply preset to local and remote No power supply preset to local and remote 110 240VAC 07M2158B UM User Manual Power Supplies 08055DCUI 100 240VAC 5V reg DC 2A Universal Input Adapter 08055 120 5 1 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Adapter 24V PSM 24 VDC Input Adapter 48V PSM 48 VDC Input Adapter Power Cords 0805US American Power Cord 080SEUR 0805UK 0805AUS 080516 0805JAP 06055 Only required with optional UI power supply 08055DCUI 17 APPENDIX C MODEL 2158B SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 e Pin 1 TX e Pin 2 TX e Pin 3 RX e Pin 6 RX e Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 e Pin 4 RING e Pin 5 TIP e Pins 1 2 3 6 7 8 no connection APPENDIX D DISTANCE CHART BASED ON 24 AWG 0 5 MM Throughput Line Rate Distance In feet at Max Distance km bits per second 10 10 3750 ft 11 538 240 DS 1 1 km 11 544 288 US Note The actual distance and link performance may vary depending on the environment and type gauge of wire used Note DS downstream US upstream Copyright O 2010 Patton Electronics Company All Rights Reserved 20
5. RJ 45 connector on the Model 2158B s twisted pair interface is polarity insensitive and is wired for a two wire interface The signal pin relationship is shown in Figure 3 o 1 no connection 1 2 no connection D ae 3 3 no connection 4 4 RING 5 5 TIP 6 no connection 8 7 no connection B 8 no connection Figure 3 Model 2158B RJ 45 twisted pair line interface 3 2 CONNECTING THE 10 100BASE T ETHERNET INTERFACE external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for The shielded RJ 45 ports labeled Ethernet are the Auto MDIX10 100Base T interface These ports are designed to connect directly to a 10 100Base T network Figure 4 shows the signal pin rela tionships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long 1 TX RX 2 Rama 3 _ 4 4 no connection 5 5 no connection 6 RXJTX 8 TT 7 no connection ss 8 no connection Figure 4 Model 2158B 10 100Base T RJ 45 Connector Pinout 3 3 CONNECTING POWER external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and
6. nee MESAS NEED anne Mee Dire ATER a eer SE E seen eee isons 14 POW GP WD C HEN 14 Front Panel LED Status Monitors seeeeeessessss 15 SDecHficalloliS erected Sn 16 EAN CONNECION nC An 16 TRANS MISSION ENE EXPL 16 COpPperuINK DISAN Geanina n Ub adire rea cenis 16 LED Status INdiCators inst mesh msn 16 OWEN SU a 16 Temperature Range uia nissan eut 16 LUC INES RE e Rc 16 DIMENSIONS SE Mr 16 Model 2158B Series Factory Replacement Parts and Accessories 17 Model 2158B Series Interface Pin Assignment 18 TOHOOBaSe T Intel a6 santas unit aei Ar uetus 18 nri M en M 18 COPperINIS M NAGER RE ee lp au pet o TR eae 18 RD CAM a No PH 18 Distance Chart Based on 24 AWG 0 5 MM 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 2158B components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of the shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not performs as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limi
7. ERFACE external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for The Model 2158B supports communication between two peer Ethernet LAN sites over a distance of up to 3 750 ft 1 1 km over 24 AWG 0 5 mm twisted pair wire Note Actual distance and link performance may vary depending on the environment and type gauge of wire used Follow the steps below to connect the Model 2158B CopperLINK Inter faces Note The Model 2158B units work in pairs One of the units must be configured as a L Local unit and the other unit must be config ured as a R Remote unit It does not matter which end is the L and which is the R The link is always initiated by the R unit As long as the L unit is powered on the R unit can establish a link by being powered on or by having its power reset 10 1 To function properly the two Model 2158Bs must be connected together using twisted pair unconditioned dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Model 2158B is equipped with an RJ 45 interface jack that can be used on the CopperLINK interface The CopperLINK interface is a two wire interface Observe the signal pin relationships on the Model 2158B s CopperLINK interface jack The
8. The 2158Bs automatically add and delete MAC addresses only passing packets across the CopperLINK link that are meant for the remote peered LAN 10 100Base TX 10 100Base TX pra Model 21588 Twisted Pair Model 21588 i P N wie V 7 ES HS K P ur E a e Local Remote Network Network Figure 1 Typical application The pair of 2158B models work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application 3 0 INSTALLATION external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for To install the 2158B Ethernet Extender do the following 1 Connect the line interface between the units refer to section 3 1 Connecting the Twisted Pair Line Interface on page 10 Note See Figure 2 for the standalone units rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100Base T Ethernet Interface on page 11 3 Connect the power plug refer to section 3 3 Connecting Power on page 12 CopperLINK twisted pair RJ 45 interface Dual 10 100 Ethernet ports Figure 2 Model 2158B standalone rear panel 3 1 CONNECTING THE TWISTED PAIR LINE INT
9. e known as hazard ous network voltages and to avoid electric shock use caution when working near these ports When discon necting cables for these ports detach the far end con nection first e Do not work on the device or connect or disconnect cables during periods of lightning activity A WARNING A WARNING In accordance with the requirements of council direc tive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling This device is NOT intended nor approved for connec tion to the PSTN It is intended only for connection to customer premise equipment Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the fol lowing to prevent ESD e Always follow ESD prevention procedures when removing and replacing cards e Wear an ESD preventive wrist strap ensuring that it makes good skin contact Connect the clip to an unpainted surface of the chassis frame to safely chan nel unwanted ESD voltages to ground e To properly guard against ESD damage and shocks the wrist strap and cord must operate effectively If no wrist strap is available ground yourself by touching the metal part of the chassi
10. he LED functions PE PATIUN CopperLINK B Ea Zlectronics Uo Ethernet Extender N S o N N eO ge gh Power Link Ethernet 1 Ethernet 2 Remote Local LED LED LED LED LED LED Figure 7 Model 2158B front panel Table 2 Front panel LED description ip Suus O Description The device is powered on The device is powered off The port is connected CopperLink CUT Haira orean oran Of Local mode is off Remote The device acts in Remote mode Remote mode is off Once the unit connects to a power source the Ethernet LEDs will blink as the 2158B automatically looks for the other unit in the pair APPENDIX A SPECIFICATIONS A 1 LAN CONNECTION e Two shielded RJ 45 10 100Base T IEEE 802 3 Ethernet e CopperLINK Connection Shielded RJ 45 A 2 TRANSMISSION LINE Two wire unconditioned twisted pair A 3 COPPERLINK DISTANCE Distance 3 750 ft 1 1 km at 10 Mbps upstream 10 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 19 for details A 4 LED STATUS INDICATORS Power Green e CopperLINK Link Green e Ethernet Link Green amp Activity Flashing Green e Remote Green Local Green A 5 POWER SUPPLY External AC and DC options e AC 120 VAC 220 VAC and UI 120 240 VAC e DC 12 VDC 24 VDC and 48 VDC e Power consumption 860mA at 5V A 6 TEMPERATURE RANGE 0 40 C A 7 HUMIDITY Up to 90 non condensing A 8 DIMENSIONS 1
11. mechanical serviceability The Interconnecting cables shall be acceptable for The Model 2158B does not have a power switch so it powers up as soon as it is plugged in An external AC or DC power supply is available separately This connec tion is made via the barrel jack on the rear panel of the Model 2158B No configuration is necessary for the power supply See Appendix B for domestic and international power supply and cord options DC power supplied via the power supply jack to the 2158B must meet the following requirements DC power supplied must be regulated 5VDC 5 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2158B has four DIP switches S1 for configuring the unit for a wide variety of applications This section describes switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the underside of the Model 2158B see Figure 5 Figure 5 Removing protective cover Figure 6 on page 13 shows the orientation of the DIP switches in the On and Off positions m E He Front Rear
12. r is encouraged to try to correct the interference by one or more of the follow ing measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equip ment into a different AC outlet such that the computing equipment and receiver are on different branches 1 3 CE DECLARATION OF CONFORMITY This device conforms to the requirements of Council Directive 2004 108 EC on the approximation of the laws of the member states relating to electromagnetic compatibility and Council Directive 2006 95 EC on the approximation of the laws of the member states relat ing to electrical equipment designed for use within certain voltage limits The safety advice in the documentation accompanying this device shall be obeyed The conformity to the above directive is indicated by CE mark on the device 1 4 AUTHORIZED EUROPEAN REPRESENTATIVE DRM Green European Compliance Services Limited Avalon House Marcham Road Abingdon Oxon OX14 1UD UK 1 5 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Services at Tel 1 301 975 1007 e Email support patton com e URL http www patton com Note Packages received without an RMA number will not be accepted
13. s 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for one year for paris and labor If any questions or problems arise during installation or use of this product contact Patton Electronics Technical Support at 1 301 975 1007 2 1 FEATURES e Variable rate CopperLINK extender Easy to configure e Auto MDIX Ethernet e Configurable 10 100 Full Half and Auto Negotiating Ethernet e Extends network connections up to 3 750 1 1 km over 2 wire 24 AWG unconditioned lines e Switch selectable line rates up to 10 Mbps Symmetric or asymmetric settings via DIP switch e Transparent operation e LED indicators for Power Link Ethernet Link amp Activity and Remote Local 2 2 DESCRIPTION The Patton Electronics Model 2158B CopperLink modems provide high speed LAN connections between peered Ethernet LANs remote PC s or any other network enabled 10 100Base T device Operating in pairs one Model 2158B is configured as the L Local unit located at one end of the LAN extension and the other Model 2158B is configured as the R Remote unit at the other end The Model 2158B is configured as a L or R via the switch on the bottom of the unit These units can automatically forward LAN broadcasts multicasts and frames across a 2 wire voice grade twisted pair link The data is passed transparently unmodified through the 2158Bs
14. ted to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 REGULATORY INFORMATION EMC Directive e FCC Part 15 Class A e EN55022 Class A EN55024 Low Voltage Direcive Safety UL60950 1 CSA C22 2 No 60950 1 e EC EN60950 1 2nd Edition e AS NZS 60950 1 e A tick 1 2 RADIO AND TV INTERFERENCE FCC PART 15 This device generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufac turer s instructions may cause interference to radio and television recep tion The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B 4 of Part 15 of FCC rules which are designed to provide reasonable pro tection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular instal lation If the device does cause interference to radio or television recep tion which can be determined by disconnecting the unit the use