Home

PASCO Specialty & Mfg. SF-9288 User's Manual

image

Contents

1. If the glass bulb is broken immediately turn lamp off and remove it to avoid possible injury Replace bulb prior to next use S1 ON OFF i 117 VAC or 220 VAC GROUND oT F1 COMMON od Schematic Model SF 9288 Spectral Lamp Power Supply and Mount 012 03048D Limited Warranty PASCO scientific warrants this product to be free from defects in materials and workmanship for a period of one year from the date of shipment to the customer PASCO will repair or replace at its option any part of the product which is deemed to be defective in material or workman ship This warranty does not cover damage to the product caused by abuse or improper use Determination of whether a product failure is the result of a manufacturing defect or improper use by the customer shall be made solely by PASCO scientific Responsibility for the return of equipment for warranty repair belongs to the customer Equipment must be properly packed to prevent damage and shipped postage or freight prepaid Damage caused by improper packing of the equipment for return ship ment will not be covered by the warranty Shipping costs for returning the equipment after repair will be paid by PASCO scientific Equipment Return Should this product have to be returned to PASCO scien tific for whatever reason notify PASCO scientific by letter or phone BEFORE returning the product Upon notification the return authorization and shipping instruc
2. 012 03048D Instruction Sheet for the PASCO Model SF 9288 Spectral Lamp Power Supply and Mount Introduction Allow about five minutes warm up time If at any time the lamp fails to come on check the fuse on the rear panel of the power supply If the fuse is blown replace only with a similarly rated fuse Fuse 2 Amp gt NOTE To insert or change the spectral lamp follow the procedure shown on the back of this page CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The PASCO Model SF 9288 Spectral Lamp Power Sup ply and Mount is designed for use with Osram 9 pin DIN base 21 mm diameter spectral lamps The Mercury lamp SF 9282 is available from PASCO scientific CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER ON UNIT NO USER SER VICEABLE PARTS INSIDE REFER SERVICING TO Mercury Spectral Lamp SF 9282 QUALIFIED SERVICE PERSONNEL Sodium Spectral Lamp SF 9289 The lightning flash with arrowhead within l an equilateral triangle is intended to alert Cadmium Spectral Lamp SF 9290 the user of the presence of uninsulated Helium Spectral Lamp SF 929 dangerous voltage within the product s enclosure that may be of sufficient magni Neon Spectral Lamp SF 9292 tude to constitute a risk of electric shock to Changing spectral lamps is easy so a single power supply eee can be used to power any one of the Osram lamps The exclamation point within an equilat To use the Spectral Lamp Power Supply an
3. d Lamp l eral triangle is intended to alert the user of the presence of important operating and maintenance servicing instruc page tions in the literature accompanying the Plug the round three pronged plug from the lamp appliance Insert a spectral lamp as shown on the back of this mount into the socket on the front of the power supply Plug the power supply power cord into a grounded Hg Lamp Contains Mercu ry 107 128 VAC 60 Hz or 206 242 VAC 50 Hz outlet Manage in accordance with See label on rear of unit Flip the ON OFF Switch on the front of the power d isposal laws supply to ON See https www lamprecycle org or 1 866 666 6850 BD J i SL 6 10101 Foothills Bivd Roseville CA 95678 9011 USA Phone 916 786 3800 FAX 916 786 8905 web www pasco com teach science Spectral Lamp Power Supply and Mount Replacing the Spectral Lamp gt CAUTION HIGH VOLTAGE Always unplug the lamp mount from the power supply Unplug the Lamp Mount cord from the power supply and allow several minutes for the lamp to cool Unscrew and remove the top screws Lift off the top Gently pull the spectral lamp up out of the 9 pin socket gt CAUTION WEAR GLOVES TO PROTECT YOUR HANDS FROM A HOT LAMP OR POSSIBLE BREAKAGE Reverse the procedure to replace the lamp gt CAUTION WHEN USING THE MERCURY LAMP SF 9282 DO NOT LOOK INTO LAMP UV RAYS MAY BE DAMAGING
4. tions will be promptly issued gt NOTE NO EQUIPMENT WILL BE ACCEPTED FOR RETURN WITHOUT AN AUTHORIZATION When returning equipment for repair the units must be packed properly Carriers will not accept responsibility for damage caused by improper packing To be certain the unit will not be damaged in shipment observe the following rules The carton must be strong enough for the item shipped Make certain there is at least two inches of packing material between any point on the apparatus and the inside walls of the carton Make certain that the packing material can not shift in the box or become compressed thus letting the in strument come in contact with the edge of the box PASC Ci

Download Pdf Manuals

image

Related Search

Related Contents

保全インフォメーションきんき 第46号  Hoefer SE600 Chroma  受信機,通信販売,無線機,VR  Life Fitness Signature Olympic Incline Bench SOIB User's Manual  Rencontres PME - V.I.E Allemagne  Draft  年額版/2年版 操作マニュアル  identificação  BE6039-11 - LumaSense Technologies  EpiQuik™ BRD2 Binding Activity/Inhibition Assay Kit  

Copyright © All rights reserved.
Failed to retrieve file