Home
Panasonic FV-05-11VK1 Installation Manual
Contents
1. 114 C Fuse i emo e Black E ene eee e Live Fan auch ewe ainn gt Power supply 2 Thermally AC120V 60Hz tect Multi Speed module m protses elle White _ E toa suse ease sc Neutral eee se AAI AR EA EN one eee paar gt FV 05 11VKSL1 M only other models J Hi Low switch When plug in not included Red L J Multi Speed module i On Off switch When plug in Plug N Play module slot H H Red other Plug N Play modules E e Non powered control wires Plug N Play module slot H H Green Green ee eens Earthi ground e u ee peg J Switch for power Te ga Black Hye light gt Power supply amp C l i White o Neutral AC120V 60Hz FEATURE For models of FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 The WhisperGreen Select Line of ventilation fans employs innovative state of the art technologies that provide a number of customizable unique features that lead to improved indoor air quality Please read the installation manual first in order to realize the benefits of this customizable modular fan Optimum Ventilation Performance Duct length elbows and other factors increase static pressure which can hinder the performance of most ventilation fans This fan utilizes SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the d
2. 5 w a Fan Time dela Human 5 a Be Motion operation operation a atve zZ i 2 FV CSVK1 onl zz 0 ny Fan 20 minutes z z F a When aa leas ma FV MSVK1 only ON OFF time delay 5 an ow excess humid Is a if speed until 3 o8 active speed detected fan sine the shay aie has FV CSVK1 FVVS15VK1 Fan pepene on Time Sag at high speed passed FV MSVK1 FV VS15VK1 Hi Low speed delay setting INSTALLATION PLUG N PLAY FUNCTION DEVICES You can purchase the specified Plug N Play devices that are explained on page 6 7 and install them in positions and Position can only be used with Multi Speed module model FV 05 11VKSL1 already have this control installed position and can be used for any of the other optional control modules 1 Remove the connector cover from position or 2 Plug in the specified devices to Base PCB box and fix to the slot till hear the sound installed in place Squeeze tabs on the Clasp to remove Squeeze insert and release the tabs on Clasp to replace INSTALLATION NEW CONSTRUCTION The fan position between joists from 16 to 24 on center can be adjusted flexibly A CAUTION Please wear gloves during the installation work as follow Machine screw 1 Disconnet plug connector from receptacle and remove adaptor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the
3. bracket is installed on joist Existing ductwork and wiring left in place Fig 14 Mastic or approved foil tape N Follow the step 1 4 5 on page 8 and step 7 on page 9 Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Joist w Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 15 4 Secure the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 16 CAUTION Secure machine screw M4X6 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw Ceiling P gt slip teeth Machine screw M4X6 x ee 5 Follow the step 10 to 16 on page 9 to 10 2 Self drilling screws Fix the inl flange and Flex Z Fast bracket through the ceiling Fig 16 MAINTENANCE I CLEANING AWARNING aD Disconnect power source before working on unit CAUTION T Routine maintenance must be done every year Re ye Ceiling Please wear gloves during the cleaning work SN Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan Vacuum Do not immerse motor in water when cleaning leaner Do not soak resin parts in water over 140 F 60 C 1 Clean grille Don t put into hot water Use non abras
4. www pa nasonic ca Panasonic corporation 2014 Printed in China 11 7 5 3 X0114 2024 11KSL1420B
5. When this product is no longer being operated please remove the product to prevent the possibility of falling Ceiling joist must be subjected to static load more than five times the weight of the product S Do not install with a method which is not approved in the instructions Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause motor humming noise This product must be properly grounded CAUTION Do not install this ventilating fan where interior room temperature may exceed 104 F 40 C Prohibited GO Make sure that the electric service supply voltage is AC 120V 60Hz Follow all local electrical and safety codes as well as the National S UP Electrical Code NEC and the Occupation Safety and Health Act OSHA Prohibited Always disconnect the power source before working on or near the fan motor light fixture or junction box a Protect the supply wiring from sharp edges oil grease hot surfaces Prohibited chemicals or other objects Adaptor Do not kink the supply wiring Provide make up air for proper ventilation Q Fig A For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Cooking area Do not install above or SO OV EVES SSH Do not install the unit where ducts are configured as shown LF TR A in Fig A AIAN Not for use in cooking area Fig B Ney ip s Cooki
6. 2 this device must accept any interference received including interference that may cause undesired operation Risk of Fire Type IC Inherently Protected Only Use LED Lamp Max 7W Type GU24 UNPACKING Unpack and carefully remove the unit from carton Refer to the Supplied Accessories list to verify that all parts are present SUPPLIED ACCESSORIES Part name Appearance Quantity Part name Appearance Quantity Installation 2 Grille instructions Warranty sheet Flex Z Fast Sg bracket aE Tapping screw i ST4 2X20 7W cap LED lamp aer dalling 1 1 2 38 1 26 4 5 8 116 Unit inches mm ii i j medene ae aes 1 m FV 05 11VKL1 m 95 5S FV 11 15VKL1 _ ee ele z neg 1 NJ 6 3 8 163 FV 11 15VKL1 7 38190 O La FV 05 11VKSL1 Part name Connector cover 13 330 Base PCB box Pick A Flow switch Motion sensor location Lighting unit i FV MSVK1 not included LED lamp q i Junction box Fan body i Adaptor F Multi Speed module L 10 1 4 260 3 78 100 3 7 8 100 FV 05 11VKSL1 only Flex Z Fast bracket other models not included WIRING DIAGRAM
7. Insulation Fig 23 Air volume at 0 1 WG CFM Power W Fan Lighting unit Weight Ib kg FV 05 11VKSL1 Exhaust FV 05 11VKL1 60 4or6 50 3 6 80 6 0 110 14 11 5 5 2 FV 11 15VKL1 Exhaust 110 8 5 130 150 HVI Certified performance based on HVI Procedures 915 916 and 920 E Specifications for Multi Speed fans Duct diameter inches Air direction Voltage v Frequency Hz Air volume Power W at 0 1 WG CFM Fan Lighting unit 11 7 5 3 FV 05 11VKSL1 FV 05 11VKL1 Plug in FV VS15VK1 Exhaust 100 8 7 90 7 0 80 6 0 70 4 7 60 3 9 50 40 30 11 5 5 2 FV 11 15VKL1 Plug in FV VS15VK1 Exhaust 120 Reference performance based on HVI Procedures 915 916 and 920 Standby wattage PRODUCT SERVICE Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Panasonic Corporation of North America Two Riverfront Plaza Newark NJ 07102 www panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario LAW 2T3
8. O PLUG N PLAY Modular Component Accessories Sold Separately Not Included With Base Model Fan E FV VS15VK1 Multi Speed module allows the fan to run continuously at lower speeds to maintain ventilation standards to meet Indoor Air Quality and then boost up to high speed to meet intermittent needs for Spot or Point Source exhaust needs The FV VS15VK1 Modular Component will operate for both the FV 05 11VKL1 and the FV 11 15VKL1 matching the appropriate Multi Speed setting shown below The FV 05 11VKSL1 comes with the FV VS15VK1 Multi Speed module It is not necessary to purchase this component Note the options on the face of the FV VS15VK1 Multi Speed module to choose appropriate levels of airflow CFM and time delay before returning back to low speed TIME Choosing the Pick A Flow setting automatically adjusts the Multi Speed setting accordingly As an example if the Pick A Flow Multi speed setting is 80 CFM the Multi Speed settings adjust automatically to be 0 30 40 50 60 or 70 CFM at the lower speeds The fan will boost to the 80 CFM speed as the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM FV 05 11VKSL1 50 o 30 40 40 40 40 40 40 40 FV 05 11VKL1 80 o 30 40 50 60 70 70 70 70 plug in
9. switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosures Canada only Not to be installed in a ceiling thermally insulated to a value greater than R40 Do not disassemble the unit for reconstruction If this unit is to be installed over a tub or shower it must be marked as appropriate for the GENERAL SAFETY INFORMATION CONTINUED AWARNING
10. tape from damper and adaptor before installation As shown below J Bend down 4 tabs Fig 2 2 Bend down 4 tabs for positioning install the Flex Z Fast bracket to joists by using 2 tapping screws ST4 2X20 Please prepare the screws and put on Flex Z Fast bracket before Flex Z Fast bracket is installed on joist Fig 2 Adjust the length of Flex Z Fast bracket as the spacing between joists and install to joists by using 2 tapping screws ST4 2X20 Fig 3 2 Tapping screws ST4 2X20 Fig 3 w 4 Remove junction box cover and secure conduit i Haile N or stress relief to junction box knock out hole foil tape Fig 4 i 5 Install a circular duct and secure it with clamps or ties and seal it with mastic or approved foil tape hole z 7 4 inch 6 inch circular duct is needed to connect to Junction bor W relevant part of common adaptor Fig 4 cover AN 2 settdniling ane A 6 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 4 l INSTALLATION NEW CONSTRUCTION CONTINUED 7 Refer to wiring diagram on page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 A CAUTION Mount junction box cover carefully so that lead wires are not pinched 8 Insert fan body and slide into ada
11. FV VS15VK1 110 o 30 40 50 60 70 80 90 100 FV 11 15VKL1 110 o 50 60 70 80 90 100 100 100 plug in Fv vs15vK1 30 9 50 60 70 80 90 100 110 110 150 0 50 60 70 80 90 100 110 120 Delay Time min 0 0 5 5 10 20 30 45 60 Factory setting 20 minutes Delay Time position 0 Manual wall switch control is 0 minute without manual wall switch control is 0 5 minute INDICATION PLUG N PLAY FUNCTION DEVICES CONTINUED PLUG N PLAY Modular Component Accessories Sold Separately Not Included With Base Model Fan E FV CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV VS15VK1 The Condensation Sensor works based on calculations from the Psychrometric Chart or combination of Relative Humidity RH and Temperature This allows the fan to anticipate the formation of condensation and automatically turn on when needed to expel humid air The Condensation Sensor is pre set to run for 20 minutes it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle E FV MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV VS15VK1 The Motion Sensor is pre set to run for 20 minutes it will then re check for movement if detected the fan will run fo
12. Panasonic INSTALLATION INSTRUCTIONS Ventilating Fan Model No FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models Contents GENERAL SAFETY INFORMATION 2 3 PLEASE READ PRIOR TO INSTALLING THIS FAN 3 4 DESCRIPTION ssoseesse eeeetd tense ueoseseenseniee 4 UNPACKING vaasveectescendevensueesuetueessacenes 4 SUPPLIED ACCESSORIES 5 DIMENSIONS 7 7 5 WIRING DIAGRAM 5 FEATURE lt eqcestadednnccneesnendddag acadadadacadas 6 FV 05 11VKSL1 FV 05 11VKL1 INDICATION PLUG N PLAY FUNCTION DEVICES 6 7 MOTION PLUG N PLAY FUNCTION DEVICES 7 INSTALLATION PLUG N PLAY FUNCTION DEVICES 8 INSTALLATION NEW CONSTRUCTION 8 10 INSTALLATION RETROFIT 10 MAINTENANCE I CLEANING 11 MAINTENANCE II REPLACEMENT OF LAMP 11 PRACTICAL GUIDE TO INSTALLATION BACK COVER SPECIFICATIONS 2 24 s5s22445 e0 0u s54 BACK COVER FV 11 15VKL1 PRODUCT SERVICE BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Failure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and maintain th
13. ceillng with caulk or other sealant to prevent air leakage Unit inches mm Fig 7 10 _ Conduit Circular duct Unit inches mm WARNING AE We INSTALLATION NEW CONSTRUCTION CONTINUED Ceiling Q Mounting spring CAUTION a O connector S ERK FV MSVK1 only a i a Before turn on the light make sure the Clasp connector at the correct position If not the lighting can t work The claw of connector must latch the rib completely LED night light FV NLVK1 only 14 Plug in the specified devices as your choice refer to installation on page 8 Insert the motion sensor FV MSVK1 only or LED night light FV NLVK1 only into slot of the grille Fix the lead wire into the clasp Fig 11 15 Adjust Pick A Flow switch if used adjust the FV VS15VK1 Multi Speed module Fig 12 Refer to indication on page 6 16 Insert the other mounting spring into the slot as shown and mount grille to fan body Fig 13 CAUTION Mount grille carefully so that lead wire of lighting unit is not pinched Fig 11 INSTALLATION RETROFIT Disconnect power source before working on unit 1 Remove the existing fan and cut ceiling openning Secure the Flex Z Fast bracket to joists by using 4 tapping screws ST4 2x20 Please prepare the screws and put on Flex Z Fast bracket before Flex Z Fast
14. e product after installation and this booklet should be presented to users Please retain this booklet for future reference GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed A WAR N N G a a Lalla hazard that could result in serious Denotes a hazard that could result in minor injury A CAUTION 7 The following symbols are used to classify and describe the type of instructions to be observed This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely This symbol is used to alert users to a specific operating procedure that must not be performed This symbol is used to alert users not to disassemble the equipment with the grounding terminal amp This symbol is used to alert users to make sure of grounding when using the equipment AWARNING To reduce the risk of fire electric shock or injury to persons observe the following Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit
15. hree speeds When fans are equipped with the optional Multi Speed module these models kick up to a maximum level of 150 CFM for the FV 11 15VKL1 and 110 CFM for the FV 05 11VKSL1 and FV 05 11VKL1 either when the switch is turned on or activated by the optional Condensation Sensor module or the optional Motion Sensor module A High Low Delay Timer located inside the fan unit is utilized to return the fan back to the pre set Continuous ventilation mode The installer needs to consult with the homeowner for the desired setting on the timer 0 60 minutes and make the adjustments during the installation DESCRIPTION These products are listed by UL under UL file No E78414 These products use a sirocco fan driven by a DC motor powered by an integral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A damper for preventing air counter flow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level The lighting unit is an energy saving LED lighting device that uses two 7W LED lamps and produces almost the same illumination as a standard 60W incandescent lamp FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against ha
16. ive kitchen detergent wipe dry with clean cloth Fig 17 2 The grille should be dry after cleaning 3 Remove dust and dirt from fan body using a vacuum Gloves Fig 17 Fig 18 cleaner Fig 18 D 4 Using a cloth dampened with kitchen detergent remove awe any dirt from fan body Wipe dry with clean cloth Fig 19 S 5 Reinstall grille V Fig 19 MAINTENANCE II REPLACEMENT OF LAMP AWARNING ae Disconnect power source before working on unit onnector Mounting spring Motion sensor FV MSVK1 only The lamp s glass is fragile be careful when the lamp is replaced Make sure the temperature of lens and lighting unit has cooled down before maintenance cleaning or replacement of lamp A Sacil O N ee plug Oe ahi S LED night light FV NLVK1 only Grille Remove dust and dirt from light cover and lens Claw connector Fig 20 before replace the lamps The LED lamps should be replaced as the specified G Remove siew type The supplied LED lamps are not intended for M4x8 other use 1 Remove grille by pulling down one mounting spring Fig 20 Remove plug connector then pull down the other For models plug in FV MSVK1 or FV NLVK1 Pull down the mounting spring that without lead wire passed side and gt remove motion sensor or LED night light as shown in Fig 20 Fig 21 Squeeze mounting spring and pull down carefully 2 Remo
17. ng Floor The special purpose or dedicated parts such as mounting equipment fixtures must be used if such parts are provided Fig B PLEASE READ PRIOR TO INSTALLING THIS FAN Spot and Continuous Ventilation These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day By utilizing the optional CustomVent Multi Speed module the fans are built to run continuously at a pre set lower level FV 05 11VKSL1 and FV 05 11VKL1 0 30 40 50 60 70 80 90 100 CFM FV 11 15VKL1 0 50 60 70 80 90 100 110 120 CFM The setting is dependent on the size of the house and the individual wishes of the homeowner It is crucial that the installer pre set the lower setting during the installation Please refer to the chart below and the switch indication on page 6 PLEASE READ PRIOR TO INSTALLING THIS FAN CONTINUED CustomVent Multi Speed module Lower Setting ASHRAE 62 2 2010 sq feet Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms lt 1 000 33 40 48 55 1 500 38 45 53 60 2 000 43 50 58 65 2 500 48 55 63 70 3 000 53 60 68 75 3 500 58 65 73 80 4 000 63 70 78 85 4 500 68 75 83 90 5 000 73 80 88 95 5 500 78 85 93 100 6 000 83 90 98 105 6 500 88 95 103 110 7 000 93 100 108 These fans are also built to take care of the homeowner s spot ventilation needs when the room is occupied The basic fan models allow a choice of t
18. ptor assy with some strength untill the flange overlaps the Flex Z Fast bracket Secure the fan body to Flex Z Fast bracket by using 2 self drilling screws plug connector to receptacle and secure the fan body to adaptor by using machine screw M4X6 Fig 6 A CAUTION Secure machine screw M4X6 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 10 Remove the tapes from louver and springs before installation Remove screw M4X8 and light cover Fig 8 IMPORTANT Replace the sensor cover before the installation only for plug in Motion sensor module FV MSVK 1 As shown below Keep on pressing the clasps when removing the ornamental cover X Gloves Sensor cover 11 Install the LED lamps Fig 9 12 Install light cover Fig 10 13 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 11 of page 10 Junction box Netural to Live to black Light wal Live to black Fan Netural to white Two red wires Connect to a general manual switch Fig 5 Machine screw axe de vf 2 Self drilling screws Fig 6 After finishing the ceiling job fill gap between flange and
19. r another 20 minutes cycle The Motion Sensor detects within the range shown below The distance that motion can be detected is limited to 10 feet 3m The field of view of the sensor is 90 Room temperature is 25 C E FV NLVK1 Nite Glo LED Night Light module automatically turns on when ambient light levels are met Turning the dial on the Modular Nite Glo Component to DARK is ideal if the fan is in an isolated room with little ambient light from nearby rooms Turning the dial to BRIGHT is ideal if there is light spill from nearby rooms Note that it is necessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 MOTION PLUG N PLAY FUNCTION DEVICES PLUG N PLAY Modular PLUG N PLAY Modular Component Accessories Components used in Sold Separately Not Included With Base Model Fan Combinations FV CSVK1 FV MSVK1 Turns the fan on for 20 minutes when either motion or excess humidity is detected AMBIENT BRIGHTNESS FV CSVK1 FV VS15VK1 Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon detection of excess humidity FV MSVK1 FV VS15VK1 Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon motion within the room
20. rmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning this product on and off the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect equipment into outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Warning This equipment must be installed by qualified person in accordance with the provided installation instructions and all applicable codes and standards Also any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment DoC Responsible Party Panasonic Corporation of North America Two Riverfront Plaza Newark NJ 07102 Customer Call Support 1 866 292 7299 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and
21. ucts This feature allows the fan to perform as rated and avoid potential installation issues Outstanding Energy Savings The WhisperGreen Select Line of fans are built using DC motor technology The DC motor is 30 70 more energy efficient than the minimum ENERGY STAR requirements gt Pick A Flow Oe 0 80 110 switch oun lt ahs 0 i 0 Note that there is ONLY ONE Plug N Play slot to insert the Multi Speed module within the base model fan There are TWO interchangeable Plug N Play slots to insert the Condensation Sensor module Motion Sensor module or Nite Glo LED Night Light module within the base model fan 05 11 MODEL 11 15 MODEL Pick A Flow Feature All the WhisperGreen Select base models of fans come with Pick A Flow speed options The Pick A Flow switch on the face of all WhisperGreen Select fans allows the option to choose 50 80 110 CFM for the FV 05 11VKL1 FV 05 11VKSL1 or 110 130 150 CFM for the FV 11 15VKL1 These fans can run continuously or intermittently depending upon the needs of the owner Air volume type CFM FV 05 11VKSL1 prosv 2 e nof ecm FV 11 15VKL1 130cFM
22. ve the screw as shown in step of Fig 21 Remove the light cover as shown in step of Fig 21 3 Replace the LED lamps CX GU24 H B 7W as shown in step and step of Fig 22 4 Install the LED lamps CX GU24 H B 7W as shown in step and step of Fig 9 Page 9 5 Install light cover Fig 10 of page 9 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain Fig 23 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors and our LED lighting unit do not create enough ambient heat to be subjected to these limitations SPECIFICATIONS E Specifications for Base Model fans Duct diameter inches Air direction Frequency Model No Hz 4 inches or 6 inches roof jack wall cap or soffit vent with backdraft damper Mechanically connect duct to termination and seal with mastic or approved foil faced tape 2 3 ft straight run before elbow In attic installation caulk box to drywall Short piece of flexible duct helps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints
Download Pdf Manuals
Related Search
Related Contents
owners manual model no. 45-02922 15 Gallon "Pro" Tow sPraYer 3M M2RX7P3E2-01 SCART TO HDMI Converter User Manual Iron Rider 2.0 - Rockwell Time EM Owners Manual Pioneer Issue 04 1014 S i tu ne bois pas ta soupe Ouïng Ouïng, Zing Zing et L`instruction du dossier de demande d`installation d`un système d Wireless made SIMPLE! Fluke 2680A Network Card User Manual Graco 313317H User's Manual Copyright © All rights reserved.