Home
Panasonic CZ-RWSY1U Installation Manual
Contents
1. Panasonic Warnings about Installation of Receivers The wireless remote uses a very weak infrared light for its signal which can result in the signal not being received because of the following influences so take care in where the unit is installed e Inverter or rapid start type fluorescent lights Models without glow lamps e Plasma display or LCD televisions e Direct sunlight or other sources of bright light Warnings about Installing Remote Controllers if a remote controller is to be operated from a remote control holder that is hung on a wall turn on the lights in the room as well as any electrical appliances and then check to make sure the air conditioner works with the remote controller in the location where it will be installed If it works continue with installation If the air conditioner is to be switched from the main sensor to a remote control sensor pay attention to the following when installing e Locate where no warm or cold drafts will affect it e Locate in a place free from direct sunlight e Locate where it will not be affected by any other heat cold source Customer Explanation Give the Operating Instructions and this manual to the customer after finishing the installation Use the Operating Instructions to explain to the customer how to use and care for the unit Things to remember when wired and wireless remotes are installed at the same time Two remote controllers can be used
2. Oil Alarm Same as operation of outdoor protection device Alternately Test Run NA A Simultaneously Off O On O Blinking 0 5 sec intervals Common to All Models The indoor unit and the wireless remote controller are equipped with indoor temperature sensors The sensing of indoor temperature works via one of them When the unit is shipped it is set to the indoor unit but to switch to the remote controller press the sensor button diagram at right inside the remote controller s cover and then check to make sure that Main Sensor on the LCD screen goes off lt Note gt Even when the sensor switch has been set to the remote controller if the unit does not receive any room temperature data from the remote controller for ten minutes it automatically switches back to the indoor unit sensor so be sure to install the remote controller facing the receiver Room Temperature Sensor Settings Sensor Button The functions of the wireless remote can be set on site These settings are saved in nonvolatile memory in the remote controller so even when its batteries are changed the settings do not revert to the defaults Setting Up Remote Control Functions lt Note gt The operation of the air conditioner can be impacted depending on the settings made so only service personnel should make the settings Furthermore making changes to these settings may cause actual oper
3. 95 F 64 F Heat temp Max 41 95 F 78 F Note 4 Heat temp Min 41 95 F 60 F Dry temp Max 41 95 F 86 F Dry temp Min 41 95 F 64 F Auto temp Max 41 95 F 80 F Auto temp Min 41 95 F 62 F Address Setting Max Value 00 ALL only gt 01 31 06 Note 5 Heat temp Max ON OFF JP Heater Max Temp Change Off JP gt EP On lt Note 2 gt When Setting OFF is selected C is displayed on the LCD screen lt Note 3 gt You can toggle between ON and OFF by pressing Ventilation for 4 seconds or more lt Note 4 gt If the Heater Max ON OFF setting is not changed to EP ON the setting change will not be reflected lt Note 5 gt This is the number of addresses that can be set in the address change mode Do not set it to 07 or above the flap cannot be stopped in a desired position Printed in Japan 85464369523010 2011 10 04 call
4. 1 Twist off the circled area shown in Fig A with pliers or similar 2 Remove the suction grille and corner cover Fig B Fig A Fig B Corner cover ai Panel wire Break off a RECEIVER_EN indd 1 INSTALLATION INSTRUCTIONS 3 4 5 6 T Fig C Fig D Pass wire through panel Pass the wire from the wireless receiver through the grille Fig C Fit the panel to the indoor unit and connect the wire from the receiver to the connector CN130 WL WHT 10P on the indoor control board Fig D After fixing the panel in place fit the receiver to the panel taking care not to trap the wire from the receiver Clamp the receiver wire and panel wire together with the supplied clamper Fig D Insert the receiver wire and panel wire into the wire saddles Fig D Refer to the Operating Instructions supplied with the panel PE Panel wire Receiver wire An Clamper L 5 CN130 WL WHT 10P XX Wire saddle lt Note 1 gt Do not twist the receiver wire and the power lead in wire together as this could lead to malfunction lt Note 2 gt If the unit power source is affected by noise install a noise filter or take similar measures Model No CZ R
5. WSY1U The Self Diagnosis Function Display and What is Detected Alarm Display in the table below indicates the content of alarms that are displayed when a wired remote controller is connected For information on how to deal with the alarms refer to the Mounting Instructions for the indoor unit or to Test Run or servicing materials Error Detected WL Remote Controller LED Display Alarm Display Timer Standby Blinking Communication error in the remote control circuit E18 E01 E03 E08 E14 E17 J Communication error either in the in outdoor operation line or the sub bus of the outdoor unit E04 E07 E15 E16 E19 E31 Operation of indoor protection device P01 PO9 P14 Alternately Operation of outdoor protection device Error in the indoor thermistor P02 P08 P15 P31 FO1 F03 F10 F11 Alternately Alternately Error in the outdoor thermistor F04 F09 F12 F28 OJO Alternately Error in the indoor EEPROM F29 O Simultaneously Error in the outdoor EEPROM F30 F31 Simultaneously Error related to the compressor H01 H31 Oje Oj Error in indoor settings L01 L03 L05 L09 Simultaneously Error in outdoor settings L04 L10 L31 O Simultaneously Inconsistency in Air Heat Including an auto temp setting for a model without auto temp settings O Alternately
6. ation to deviate from what is printed in the Operating Instructions so be sure to explain this to the customer fully Making Settings Do with unit stopped 1 Holding down the Swing Wind Direction OFF Timer Ca 2 Use the Temperature setting buttons CA gt C to select the number of the item to be set id Use the ON Timer buttons to change settings Mode Select buttons at the same time for 4 or more seconds makes the display switch to the setting screen See Diagram Below 4 The settings are saved with the Once Every Day button When this is done the settings display of the LCD changes from blinking to light 5 If other settings are to be changed as well repeat steps 2 to 4 6 When all settings have been made press the Start Stop button Example Operation mode setting screen lt Note 1 gt While the unit is in the swinging mode Swing Wind Direction Item Number Item Number amp Setting Item Setting Content Setting when Shipped Operation Mode O RS Flap Display Select Fan Speed fee gt e gt No Display Note 1 Wiss gt mws gt sw gt No Display Display of Set Temperature F Setting Off Note 2 gt C Time Display AM PM gt 24 Hour No Display AM PM Ventilation Fan ON OFF Off No Display gt On OFF Note 3 Cool temp Max 41 95 F 86 F Cool temp Min 41
7. to control the unit if the wireless remote controller is installed at the same time as the wired remote controller Up to 2 remotes a wireless remote controller and the wired remote controller can be installed When using 2 remotes one or more units can be operated by the remotes lt Note gt When wiring remote controllers be sure to double check the terminal numbers of the indoor unit before connecting them so there are no mistakes in the wiring Damage will occur if high voltage e g supply voltage is applied lt Note gt Itis not possible to use more than one wireless remote controller with one indoor unit A receiver located separately can be used at the same time lt Note gt If both a wireless and a wired remote controllers are to be installed and used at the same time one of them must be set up as the sub remote controller If the wired remote controller is to be the sub remote change the wired remote controller to the sub remote If the wireless remote controller is to be the secondary turn the switch on the wireless receiver from MAIN to SUB Accessories Parts Remote control holder Receiver AAA alkaline battery Tapping screw Remote Controller a Clamper Installing the Receiver As the receiver can only be installed in the corner where the panel wire comes out as shown in Fig A consideration should be given to orientation when fitting the panel to the indoor unit