Home
Panasonic CS-E12NKUAW Operation Manual
Contents
1. e Operating the unit within the recommended temperature could induce energy saving HEAT mode 68 F 75 F 20 C 24 C COOL mode 78 F 82 F 26 C 28 C DRY mode 2 F 4 F 1 C 2 C lower than room temperature 3 TO SELECT OPERATION MODE AUTO mode For your convenience During operation mode selection the power indicator blinks e Unit selects operation mode every 10 minutes according to temperature setting and room temperature For Single Split System e Unit selects operation mode every 3 hours according to temperature setting outdoor and room temperature For Multi Split System HEAT mode To enjoy warm air Unit takes a while to warm up The power indicator blinks during this operation COOL mode To enjoy cool air e Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED AUTO gt u gt un gt EEE sans gt Benn FAN SPEED e For AUTO the indoor fan speed is automatically adjusted according to the operation mode 5 TO ADJ UST VERTICAL AIRFLOW DIRECTION AUTO D Pe gt A gt NDS AIR SWING e Keeps the room ventilated e In COOL DRY mode if AUTO is set the louver swing up down automatically e In HEAT mode if AUTO is set the louver fix at predetermined position TO
2. 1 year Mettre en place des piles AAA ou RO3 dur e de vie d environ 1 an Close the cover Remettre le couvercle en place Press CLOCK Appuyer sur CLOCK Set time R gler l heure O oOo A W N Confirm Confirmer SET CHECK CLOCK RESET 1 MODE ces gt HEAT DRY lt COOL Select the desired mode S lectionner le mode voulu AIR CONDITIONER 1 2 OFF ON Start stop the operation Mettre l appareil en hors marche TEMP air SWING V QUIET POWERFUL AC RC e e SET CHECK CLOCK RESET Panasonic GNVERTER 3 TEMP Select the desired temperature R gler la temp rature souhait e Panasonic Corporation Website http panasonic net Panasonic Canada Inc Website http www panasonic com Panasonic Corporation 2013 Printed in Malaysia Pour les Etats Unis seulement F569580 Imprim en Malaisie For inquiries U S A please call 1 800 851 1235 SS1213 1
3. Diagnostic dis play Abnormality Protection control H 00 No memory of failure H 37 Outdoor liquid pipe temperature sensor H 11 Indoor outdoor abnormal communication abnormality H12 Indoor unit capacity unmatched H 38 negor oudgor mismatch orana code H14 Indoor intake air temperature sensor H 39 Abnormal indoor operating unit or standby abnormality units H15 Compressor temperature sensor H 64 Outdoor high pressure sensor abnormality abnormality H 97 Outdoor fan motor mechanism lock H 16 Outdoor current transformer CT H 98 Indoor high pressure protection abnormality H 99 Indoor operating unit freeze protection H 19 Indoor fan motor mechanism lock F11 4 way valve switching abnormality 4 H 23 He exchanger temperature sensor F 17 Indoor standby units freezing abnormality F 90 Power factor correction PFC circuit H 24 Indoor heat exchanger temperature sensor protection 2 abnormalit F 91 Refrigeration cycle abnormality H 27 Outdoor air temperature sensor l abnormality F 93 Compressor abnormal revolution H 28 Outdoor heat exchanger temperature F 94 Compressor discharge pressure overshoot sensor 1 abnormality protection H 30 Outdoor discharge pipe temperature F 95 Outdoor cooling high pressure protection sensor abnormality F 96 Power transistor module overheating H 32 Outdoor heat exchanger temperature protection sensor 2 abnormality F 97 Compressor over
4. UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons including The illustrations in this manual are for children with reduced physical sensory or mental capabilities or explanation purposes only and may lack of experience and knowledge unless they have been given differ from the actual unit They are supervision or instruction concerning use of the appliance by a subjected to change without notice for person responsible for their safety Children should be supervised future improvement to ensure that they do not play with the appliance Please consult authorized dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper OPERATION CONDITION installation and handling will cause leakage electric shock or fire Use this air conditioner under the following Confirm to authorized dealer or specialist on usage of specified temperature range refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Temperature Indoor O ae OFC x x Do not install the unit in a potentially explosive or flammable CR atmosphere Failure to do so could result in fire COOLING 60 8 16 51 BIN Do not insert your fingers or other objects into the air N conditioner indoor or outdoor unit rotating parts may N earns Ams UH S i i Do not touch the outdoor unit during lightning it may cause electric sock aor CU EONKUA CU E12NKUA mile p
5. ENJ OY QUIET OPERATION Quer aN e This operation reduces airflow noise TO REACH TEMPERATURE ps QUICKLY ax Single Split System This operation stops automatically after 20 minutes e Multi Split System Press the button again or turn OFF the unit to stop this operation Press and hold for 5 seconds to dim or restore the units indicator brightness Press and hold for approximately 10 seconds to show temperature setting in F or C Press and hold for approximately 5 seconds to show 12 hour am pm or 24 hour time indication Press to restore the remote control s default setting Not used in normal operations NOTES QUIET POWERFUL D Co e Can be activated in all modes and can be cancelled by pressing the respective button again e Cannot be selected at the same time TOFS Een ER MER To turn ON or OFF the unit at a preset time ON siy sms TIMER 1 2 CAN z OFF A m Seo a Set the time Confirm OFF timer on To cancel ON or OFF timer press or or then press y e When ON Timer is set the unit may start earlier up to 35 minutes before the actual set time in order to achieve the desired temperature on time e Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remote Control Preparation on the back cover e If timer is cancelled manually or due to power failure yo
6. Panasonic Operating Instructions Air Conditioner Model No Indoor Unit Single Split CS E9NKUAW Outdoor Unit CS E12NKUAW CU E9NKUA CU E12NKUA Multi Split Outdoor Unit CU 2E18NBU CU 5E36QBU QUICK GUIDE E GUIDE SOMMAIRE LO ENGLISH 2 10 Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference FRAN AIS 11 20 Instructions d utilisation Climatiseur Merci d avoir achet un climatiseur Panasonic Instructions d installation en annexe Avant d utiliser le climatiseur lire ces instructions d utilisation et les conserver pour s y r f rer dans le futur F569580 SAFETY PRECAUTIONS TAB PEXOFICONHNE NS To prevent personal injury injury to others or property damage please comply with the following Incorrect operation due to failure to follow instructions below may cause harm or damage the seriousness of which is classified as below This sign warns of death or WARNING serious injury This sign warns of injury or CAUTION damage to property The instructions to be followed are classified by the following symbols This symbol denotes an action TROUBLESHOOTING that is PROHIBITED 8 9 TRE These symbols denote an INFORMATION Qe E actions that is COMPULSORY 10 QUICK GUIDE BACK COVER WARNING NOTE INDOOR
7. cate the indoor unit is standing by for different operation mode ff 4 NES Aga Lia Multi Split Outdoor Unit Bedroom POWER YS UPB LY Time Delay Circuit Rated Volts Models Number Breaker CS E9NKUAW CU E9NKUA 15 Amps Single Split System CS E12NKUAW CU E 12NKUA 15 Amps avers ne CS E9NKUAW CS E12NKUAW CU 2E18NBU 25 Amps ps CS EONKUAW CS E12NKUAW CU 5E36QBU 45 Amps For complete product features please refer catalogue INDOOR UNIT eSwitch off the power at the circuit breaker before cleaning eDo not touch the aluminium fin sharp parts may cause injury CLEANING INSTRUCTIONS Do not use benzene thinner or scouring powder e Use only soap pH7 or neutral household detergent e Do not use water hotter than 104 F 40 C 1 INDOOR UNIT Wipe the unit gently with a soft dry cloth 2 FRONT PANEL Remove Front Panel e Raise and pull to remove the front panel e Wash gently and dry Close Front Panel e Press down both ends of the front panel to close it securely 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 HORIZONTAL AIRFLOW DIRECTION LOUVER 6 VERTICAL AIRFLOW DIRECTION LOUVER Do not adjust by hand Manually adjustable HINT e To ensure optimal performance of the unit cleaning maintenance has to be carried out at regular intervals A dirty unit may cause malfunction and you may see error code H99 Please consult authoriz
8. ed dealer 7 AUTO OFF ON BUTTON e Use when remote control is misplaced or a malfunction occurs 9 Press and hold until you hear one beep then release Automatic Force cooling Normal cooling Repeat step 2 Press and hold 3 until you hear two beeps then release Repeat step 3 Press and hold 4 until you hear three beeps then Force heating release Press the button to turn off 8 AIR PURIFYING FILTER Vacuum the air purifying filter 4 It is recommended to clean the filter every 6 months e Replace the filter every 3 years or replace any damaged filter Part no CZ SA20P 9 AIR FILTERS e Air filter cleaning is required every two weeks e Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters ENGLISH REMOTE CONTROL Maximum distance 26ft 8m INDICATOR POWER Green m TIMER Orange R QUIET Orange POWERFUL Orange Remote Control display 0 S wuz b F ay CooL f ET FAN Ve EP TER y j Press the remote control s button ula POWER 4 1 TO TURN ON OR OFF THE UNIT e Please be aware of the OFF indication on the remote control display to prevent the unit from starting stopping improperly 2 TO SET TEMPERATURE e Selection range 60 F 86 F 16 C 30 C
9. eration Ensure drainage pipe is connected properly and keep drainage outlet clear of gutters containers or does not immersed in water to prevent water leakage After a long period of use or use with any combustible equipment aerate the room regularly After a long period of use make sure the installation rack does not deteriorate to prevent the unit from falling down ENGLISH REMOTE CONTROL Do not use rechargeable Ni Cd batteries It may damage the remote control To prevent malfunction or damage of the remote control e Remove the batteries if the unit is not going to be used for a long period of time e New batteries of the same type must be inserted following the polarity stated This equipment must be earthed to prevent electrical shock or fire Prevent electric shock by switching off the power Before cleaning or servicing Extended non use Abnormally strong lightning activity 4 MULTI AIR CONDITIONER SYSTEM Multi Split Outdoor Unit CU 2E18NBU CU 5E36QBU DEFINITION Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit INDOOR UNIT e It is possible to operate the indoor units individually or simultaneously The operation mode priority is given to the first unit that turned on e During operation heating and cooling mode can not be activated at the same time for different indoor unit The power indicator blinks to indi
10. frequently e Burning smell is observed Abnormal noise or vibration of the unit is observed Water leaks from the indoor unit Power cord becomes abnormally hot Fan speed cannot be controlled The unit stops running immediately even if it is switched on for operation The fan does not stop even if the operation is stopped Contact your local dealer immediately for maintenance or repair assistance Do not wash the indoor unit with water benzene thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not touch the sharp aluminium fin sharp parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aerate the room properly before operating the unit Do not install the unit in oily and smoky areas to prevent damage to the unit Do not dismantle the unit for cleaning purpose to avoid injury Do not step onto an unstable bench when cleaning the unit to avoid injury Do not place a vase or water container on the unit Water may enter the unit and degrade the insulation This may cause an electric shock Do not open window or door for long time during COOL DRY mode op
11. heating protection H 33 Indoor outdoor misconnection abnormality F 98 Total running current protection H 36 Outdoor gas pipe temperature sensor F 99 Outdoor direct current DC peak detection abnormality For cooling only model it is the indication when indoor heat exchanger sensor or indoor air intake sensor has abnormality ENGLISH INFORMATION FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON SERVICEABLE CRITERIAS e Check remote control batteries SWITCH OFF POWER AT THE CIRCUIT e No obstruction at air inlet and air outlet vents BREAKER then please consult an authorized e Use Auto OFF ON button to select Cooling Heating operation dealer under the following conditions After 15 minutes of operation it is normal to have the following Abnormal noise during operation temperature difference between air inlet and air outlet vents Water foreign particles have entered the remote Cooling 2 14 4 F 8 C Heating 2 25 2 F 14 C control e Water leaks from Indoor unit FOR EXTENDED NON USE e Circuit breaker switches off frequently Activate Heat mode for 2 3 hours to remove moisture left in the e Switches or buttons are not functioning properly internal parts thoroughly to prevent mould growth Switch off power at the circuit breaker e Remove the remote control batteries Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposal in other Countries outside the Eu
12. i yourself directly to cold air for a long period to avoid DBT BT 114 8 46 78 8 26 Do not sit or step on the unit you may fall down Q COOLING Min 5 0 15 accidentally UN HEATING 75 2124 64 4 18 Min 50 15 3 216 RARE Tea L vin aon Control a in 50s 326 DBT Dry bulb temperature WBT Wet bulb temperature Cause Injury Air Inlet CAUTION A wasninc REMOTE CONTROL INDOOR UNIT AND OUTDOOR UNIT Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries POWER SUPPLY Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To prevent overheating fire or electric shock Do not share the same power outlet with other equipment Do not operate with wet hands Do not over bend the power supply cord If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is strongly recommended to install this unit using an Earth Leakage Circuit Breaker ELCB or Ground Fault Interrupt GFCI or Appliance Leakage Current Interrupt ALCI to prevent electric shock or fire Stop using the product if any abnormality failure occurs or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB or GFCI or ALCI trip
13. o part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance follow the attached installation instructions Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Industry Canada Notice This Class B digital apparatus complies with Canadian ICES 003 QUICK GUIDE GUIDE SOMMAIRE Remote Control Preparation e Pr paration de la t l commande 1 Pull out D gager le couvercle Insert AAA or R03 batteries can be used
14. ropean Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Sa Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Pb Contact your local hazardous waste disposal hotline Models Numb CS E9NKUAW CU E9NKUA Dre CS E12NKUAW CU E12NKUA The above listed models have been designed and manufactured to meet ENERGY STAR criteria for energy efficiency when matched with appropriate coil components However proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency Installation of this product should follow the manufacturer s refrigerant charging and airflow instructions Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life Federal Communications Commission Interference Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant t
15. the expansion contraction of the unit Check the following before calling for servicing SYMPTOM Heating Cooling operation is not working efficiently Noisy during operation Remote control does not work Display is dim or transmission signal is weak The unit does not work The unit does not receive the signal from the remote control gt 4 4 CHECK Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents e Check if the unit has been installed at an incline Close the front panel properly Insert the batteries correctly e Replace weak batteries e Check if the circuit breaker is tripped e Check if timers have been set Make sure the receiver is not obstructed e Certain fluorescent lights may interfere with signal transmitter Please consult authorized dealer TROUBLESHOOTING The unit stops and the TIMER indicator blinks Use remote control to retrieve error code 1 Press for 5 seconds 3 Press for 5 seconds to quit checking SET CHECK CLOCK RESET 2 Press until you hear beep sound then write down the error code 4 Turn the unit off and reveal the error code to authorised dealer e For certain errors you may restart the unit for limited operation with 4 beeps when operation starts Diagnostic display Abnormality Protection control
16. u can restore the previous setting once power is resumed by pressing mas ENGLISH TROUBLESHOOTING The following symptoms do not indicate malfunction SYMPTOM Mist emerges from indoor unit Water flowing sound during operation The room has a peculiar odor Indoor fan stops occasionally during automatic fan speed setting Airflow continues even after operation has stopped Operation is delayed a few minutes after restarting Outdoor unit emits water steam TIMER indicator is always on POWER indicator blinks during HEAT mode with no warm air supply and louver is closed Indoor fan stops occasionally during heating operation Power indicator blinks before the unit is switched on Cracking sound during operation vv gt vvvyv CAUSE e Condensation effect due to cooling process e Refrigerant flow inside the unit e This may be due to damp smell emitted by the wall carpet furniture or clothing e This helps to remove the surrounding odours Extraction of remaining heat from the indoor unit maximum 30 seconds e The delay is a protection to the unit s compressor Condensation or evaporation occurs on pipes The timer setting repeats daily once set The unit is in defrost mode and AIR SWING is set to AUTO To avoid unintended cooling effect e This is a preliminary step in preparation for the operation when the ON timer has been set e Changes of temperature caused