Panasonic 26PET1U6 Data Sheet
Contents
1. 11 1 2 3 1 2 4 1 16 SHE 3 4 5 25 32 7 7 32 Outdoor Dimensions indian 4 21 64 gt 1 31 32 1 31 32 Hole for anchor bolt 4 R6 5 Anchor bolt M10 Refrigerant tube joint liquid line tube Flare connection 3 8 in 9 52 mm Refrigerant tube joint gas line tube Flare connection 5 8 in 15 88 mm 13 3 8 15 3 4 Refrigerant tubing inlet knock out hole Power supply inlet knock out hole 38 629 019 616 mm 1 1 16 i EE 30 45 64 Dimension inch Panasonic Panasonic North America Air Conditioning Division 1690 Roberts Blvd NW Suite 110 Kennesaw GA 30144 us panasonic com aircon
2. Air Conditioning Division 1690 Roberts Blvd NW Suite 110 Kennesaw GA 30144 us panasonic com aircon Indoor Dimensions 6 3 32 3 15 16 eee ON S Qu Dimension inch SIS 11 482 SIE LOM N LON LO LL Drain connection A Drain connection for left side Refrigerant liquid line 3 8 Flare connection lt a N N N N t A I A S Refrigerant gas line 5 8 Flare connection 3 3 8 5 3 4 9 16 X Hole for rear side refrigerant tubing 3 9 32 xv Hole for through the wall refrigerant tubing 03 15 16 hole an En Hole for fresh air intake Knockout hole Holes in the rear side View from front Hole for wall through piping View from front Hole for right side refrigerant tubing Knockout hole a Hole for left side drain connection Knockout hole S Hole for power supply Conduit size 1 2 i Infrared rays receiver for wireless remote controller oF amii Cutting position for fresh air intake 2 5 1919 THS 1 Fo Or TS Sl 5 2 25 32 T Q Ni c T 12 8 i 50 13 32 wn o LLULL L SS 48 7 16 Suspension bolt hole pitch al 3 8 40 10 Air outlet Lor more 51 3 16 or more Service space Service space 2 ft or more
3. Split System Submittal Data Panasonic System 26PET1U6 Indoor S 26PT1U6 Outdoor U 26PE1U6 Single Split System Ceiling Suspended Heat Pumps Job Name Location Engineer Submitted to Submitted by Reference General Data TTT Outdoor Unit El _ as Indoor Unit el Fin Type Pipe Type Rows FP Approval Date Construction Unit Drawing 100 outdoor higher po Dimensions HxWxD Indoor Unit Crated in Indoor Unit Uncrated in Outdoor Unit Crated in Outdoor Unit Uncrated in Weight Lbs Indoor Net Indoor Shipping Outdoor Net Outdoor Shipping newer Silane Wawra B ENE Performance Data fa ARI Standard Conditions 230V Option Cooling Refrigerant Line Set Available Total Capacity BTU H 24 400 9 500 24 400 Fresh Air Intake Sensible Capacity BTU H 14 330 Latent Capacity BTU H 10 070 Indoor Frame Extension SEER Condensate Drain Pump Available Dehumidification Pints H Non Removeable Remo con Available Amps A 156 173 Bracket Power Inputs W 2 880 2 880 Outdoor Sound Rating dB A Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp aA 30 800 8 000 30 800 HSPF 10 3 Amps A 16 4 18 1 Total Capacity BTU H Features Controls Microprocessor Remote Controller LCD Wired Type Temp Sensor Built in Power Failure Automatic Built In Changeover Changeover Panasonic Panasonic North America
Download Pdf Manuals
Related Search
Related Contents
Avaya CallPilot 2.5 Unified Messaging User Guide Save Samsung SPH-L300ZSASPR User's Manual UNE BARRIERE CONÇUE POUR UN USAGE INTENSIF LAND ROVER DELL OptiPlex 9010 TRADUCTRICE DU FRANÇAIS VERS L`ALLEMAND Copyright © All rights reserved.
Failed to retrieve file