Home
Outback Power Systems Systems User's Manual
Contents
1. agement Each is a DC to AC La F X sinewave inverter battery dd charger and AC transfer switch housed within a tough die cast aluminum chassis Just like the local utility grid the inverter produces true sinewave AC electric ity for your stand alone or backup power needs Com puters TVs and pumps are just some of the examples of modern electronics that last longer and run better when powered with true sinewave electricity from an OutBack inverter Starting up your air conditioning washing machine or well pump is worry free because of our high surge power capability Batteries and generators are the costly consumables when using inverters to generate electricity The integrated smart battery charger uses multiple stages to perform quick recharging while prolonging battery life saving your batteries and generator from unnecessary wear Automatic switching between AC power sources is seamless due to an AC transfer switch that reacts in less than 16 milliseconds Unique networked communication is built into all OutBack products pro viding complete integration Expanding your system with your growing power needs is as simple as adding additional inverters with modular architecture Further flexibility is provided with the ability to be connected at any time in ei ther parallel series or three phase power configurations Industry leading OutBack reliability is achieved through simplified design and rugged c
2. type fuse holders for high voltage systems maximum open circuit voltage of 600 VDC e Includes dual combining bus bars which can be installed to provide one or two separate PV output circuits from a single PSPV enclosure e Includes one terminal bus bar TBB and has mounting holes for an additional TBB e Includes two 1 0 AWG set screw compression type box lug terminals for output wiring e Includes one 1 0 AWG ground lug which can be mounted either on the inside or outside surface of the enclosure e Two 1 inch side knockouts which can be punched out to allow for larger 1 25 3 cm conduit e Eight 5 13 mm knockouts on bottom for PV module or subarray input wiring e Clearance is provided on bottom and back main knockouts to allow up to a 2 5 cm conduit punch for larger cabling e For negative or positive ground PV systems e Enclosure ships without breakers or fuse holders Order separately Photo courtesy of Bob O Schultz Electron Connection 20 OutBack Power Systems Inc 2005 Photovoltaic PV Array Breakers PV breakers are Hydraulic Magnetic type and are not affected by high ambient temperatures All breakers have a 10 year warranty Maximum of twelve OBPV in one PSPV enclosure PV Array Breakers Specifications Model Rating OBPV 2 2 amps 150 VDC OBPV 4 4 amps 150 VDC OBPV 6 6 amps 150 VDC OBPV 8 8 amps 150 VDC OBPV 9 9 amps 150 VDC OBPV 10 10 amps 150 VDC OBPV 15 15 amps 150 VDC PV Array Fuses OBPV 30
3. MATE The MATE system display and controllers are complete management tools for your OutBack Power system Through the use of a single MATE you can remotely manage and monitor multiple inverter chargers MX60s and any future OutBack power conversion and control products The MATE and MATE2 are packed full of features to make system management simple The easy to read 3 1 8 cm LCD is backlit for dark operating conditions Four soft keys allow easy context based navigation of menus and functions Two hot keys give immediate access to AC and inverter functions A built in clock and calendar function enables timer based program ming of inverter and charger operation This permits you to set the system to work with time of day power rates or to limit a generators run time to a specific time period of the day or week All of your settings are stored in permanent memory to eliminate the need to reprogram in the event of a system shutdown or battery replacement The MATE and MATE2 include a RS232 port with DB9 jack for connection to the serial port of a PC computer Through the use of optional WinVerter software you can perform such operations as data logging and graphical display of the systems operation and performance MATE2M The MATE2M is the same technology as the MATE and MATE2 but is designed to be used with your M series inverter chargers in mobile applications Incorporating a more simplified menu the settings needed for
4. PS2 IOB 50DE 230 VAC 50 Hz 50 amps at 230 VAC 50 amps at 230 VAC 50 amps at 230 VAC PS2 DC Breaker Configurations The PS2DC Breaker Panel has eight small 75 19 mm three medium 1 26 mm or two large 1 5 32 mm breaker positions The small sizes are 1 80 amps medium sizes are 100 or 125 amps an the large sizes are 175 or 250 amps PS2 Mounting Plate The PS2MP is a steel powder coated one part mounting plate for all your PS2 series accessories and up to two OutBack Inverter Chargers PS2 Mounting Plate Specifications Model Dimensions Unit H x W x D Dimensions Shipping H x W x D Weight Shipping PS2MP 20 x 44 x 75 51 x 112 x2 cm 22 25 x 49 5 x 3 56 x 126 x 8 cm 24 Ibs 10 8 kg 2005 OutBack Power Systems Inc 15 System Accessories PS4 The PS4 series is the ideal AC and DC enclosure system for medium to large size renewable energy power conversion system The PS4 is comprised of two compact enclosures for all of your systems AC and DC components It saves time money and space by combining disconnects over current protection devices and control components into easy to install enclosures The PS4 is capable of supporting up to four OutBack FX series inverter chargers six MX60 charge controllers a MATE system controller and all the required AC and DC components and wiring The OutBack PS4 system can be fully customized to your application and ordered pre wired or as individual components for
5. 30 amps 150 VDC and Fuse Holders DIN rail snap in mount with 8 AWG setscrew type compression terminals Touch safe design Not rated for load make or load break usage UL listed for up to 600 VDC Maximum of eight fuse holders in one PSPV enclosure PV Array Fuses Specifications Model Description ier OBFH Fuse Holder only OBF 6 6 amp 600 VDC i pl OBF 10 10 amp 600 VDC r OBF 15 15 amp 600 VDC T nal and G d Bus B Terminal and ee aM esis dial at Ground Bus Bars Specifications Use for adding more wire terminations or for isolating multiple Hode bese tation positive negative circuits Has three 1 0 to 14 AWG and eight aa ee ee 6 to 14 AWG screw type compression terminals which means l GBB Ground terminal Bus bar no ring lugs required 2005 OutBack Power Systems Inc 21 Cuts Power S Main Office European Office 19009 62nd Avenue NE Urb Garraf Il Buz n 214 Arlington WA 98223 USA C Eramprunya 26 Phone 360 435 6030 08860 Les Botigues de Sitges Fax 360 435 6019 Barcelona ESPANA Phone 34 600 843 845 www outbackpower com
6. VDC 80 amps DC OBDC 250 FX2524T 24VDC 2500 VA 120 VAC 60 Hz 20 8 amps AC 20 Watts 6 Watts 92 2 5 2 70 amps AC 50 amps AC 6000 VA 4800 VA 3200 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 21 0 to 34 0 VDC 55 amps DC OBDC 175 FX3048T 48 VDC 3000 VA 120 VAC 60 Hz 25 0 amps AC 23 Watts 6 Watts 93 2 5 2 70 amps AC 50 amps AC 6000 VA 4800 VA 3200 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 42 0 to 68 0 VDC 35 amps DC OBDC 100 Standard 2 year Optional 5 year 62 6 Ibs 28 4 kg 67 lbs 30 kg 13 x 8 25 x 16 25 33 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm 24 VDC 2500 VA 120 VAC 60 Hz 20 8 amps AC 20 Watts 6 Watts 92 2 lt 5 2 70 amps AC 50 amps AC 6000 VA 4800 VA 3200 VA 60 amps AC 80 to 150 VAC 58 to 62 Hz 21 0 to 34 0 VDC 55 amps DC OBDC 175 Sealed Models GTFX2524 GTFX3048 48 VDC 3000 VA 120 VAC 60 Hz 25 0 amps AC 20 Watts 6 Watts 93 2 lt 5 2 70 amps AC 50 amps AC 6000 VA 4800 VA 3200 VA 60 amps AC 80 to 150 VAC 58 to 62 Hz 42 0 to 68 0 VDC 35 amps DC OBDC 100 Standard 2 year Optional 5 year 62 6 lbs 28 4 kg 67 lbs 30 kg 13 x 8 25 x 16 25 33 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm Vented Models VFX2812 12 VDC 2800 VA 120 VAC 60 Hz 23 3 amps AC 20 Watts 6 Watts 90 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA
7. amps AC 50 amps AC 3300 watts DC stc rating 150 VDC 44 to 135 VDC Standard 80 amp DC 91 CEC Certified 93 98 89 92 48 VDC 40 to 60 VDC 45 amps DC 60 amps DC 5 120 VAC 30 0 amps AC 25 0 amps AC 2 VAC THD lt 5 current THD per UL1741 conditions lt 16 Milliseconds Included 40 C to 60 C power derated above 25 C 4 kWHRS at 80 discharge Four AGM type 31 or type 27 sealed VRLA Optional MATE system display with RS232 port Powder coated aluminum stainless steel hardware Wall mount 16 on center studs 5 16 x 2 5 Lag Bolts three per side minimum 31 3 x 17 25 x 12 9 80 x 44 x 33 cm 40 5 x 20 5 x 17 25 103 x 52 x 44 cm 36 25 x 17 25 x 12 55 92 x 44 x 32 cm 43 25 x 20 25 x 16 75 110 x 51 x 43 cm 107 lbs 49 kg 117 lbs 53 kg 29 Ibs 13 kg 47 lbs 21 kg ETL certified to the UL1741 standard UL1741 compliant 5 year limited repair warranty standard MATE or MATE2 remote system display OBAC breakers for additional AC load circuits OBPV breakers for PV array series string protection OutBack Power Systems Inc 13 System Accessories PS2 OutBack Power offers compact enclosures for all of the AC and DC components of a renewable energy power conversion system The PS2 series saves time money and space by combining the disconnects over current protection devices and control components into easy to install enclosures Capable of supporting one or two OutBack FX
8. completed Automatic with optional RTS installed 5 0 mV per C per battery cell 30 mV per C for a 12 VDC system Can charge a lower voltage battery from a higher voltage PV array 98 at 60 amps with a 48 V battery and nominal 48 V solar array 3 1 8 cm backlit LCD screen with 4 lines with 80 alphanumeric characters total Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable 8 wires Last 64 days of operation amp hours watt hours and time in float for each day along with total lifetime power production Consult factory for approved turbines Requires two pole breakers for switching both positive and negative conductors on both solar array and battery connections Minimum 40 to maximum 60 C Power capacity of the controller is derated when above 25 C Indoor Type 1 Two 5 13 mm and 75 19 mm on the back One 75 19 mm and 1 25 mm on each side Two 75 19 mm and 1 25 mm on the bottom Standard 2 year Optional 5 year 11 6 Ibs 5 3 kg 14 lbs 6 4 kg 13 5 x 5 75 x 4 40 x 14 x 10 cm 18 x 11 x 8 46 x 30 x 20 cm Note Add 1 to the solar arrays open circuit voltage for every 2 5 C expected below the 25 C standard panel rating STC The resulting value must be below 150 VDC at the lowest expected temperatures conditions and less than 135 VDC for typical conditions to ensure reliable operation 6 OutBack Power Systems Inc 2005 System Display and Controller
9. field assembly PS4AC Breaker Panel The PS4AC is a NEC compliant enclosure engineered to contain all the AC overcurrent protection and power management components e ETL listed indoor type powder coated steel enclosure with plenty of knockout and mounting provisions for a variety of OutBack products e Available without the AC bypass assembly included PS4AC Order all required AC breakers separately e Available with a four FX inverter ready 60 amp 120 240VAC AC bypass assembly PS4 IOB 60Q for systems with AC generators or utility grid connections up to 15 kW e Available with a four FX inverter ready 100 amp 120 240VAC AC bypass assembly PS4 IOB 100Q for systems with large AC generators or grid connections over 15kW e Available with a four FX inverter ready 60 amp 230VAC 50 Hz AC bypass assembly PS4 IOB 60QE for export applications Ground terminal bus bar bonded to cabinet One white insulated AC neutral terminal bus bar Two black insulated AC hot leg 1 terminal bus bars Two red insulated AC hot leg 2 terminal bus bars Complete wiring kit is included when the AC bypass kit is included or ordered separately Space provided for up to 13 additional OutBack AC load breakers e Provisions for mounting an X 240 autotransformer and optional cooling fan e Knockouts on five surfaces to facilitate conduit and inverter connections PS4DC Breaker Panel The PS4DC is a NEC compliant enclosure engineered to contain all the DC overcurrent protectio
10. position even upside down The required AC input neutral ground switching is taken care of by a fully integrated 30 amp AC transfer switch for shore chord or generator hook up Three circuit boards and a simple design make field servicing the unit easy no matter where you are Rigorous testing at the factory ensures that each inverter charger works the first time as well as for many years to come Wherever you are in the world OutBacks European and Export off grid inverter chargers are engineered to provide your home or business with reliable 50 Hz AC power Our high surge power capability starts the most demanding of 230 volt appliances and the modular system architecture makes expanding a system s power capacity or switching to three phase output power simple and trouble free Both sealed FX and vented VFX models are available with 50 Hz output to match your installation s envi ronmental conditions The inverter chargers low weight as low as 27 kilograms and compact dimensions allow easy transport and installation in less than ideal locations Our field serviceable design eliminates the need to ship inverters if repair or upgrades are required Superior technical support is available from our European office allow ing questions to be promptly answered and any problems to be quickly resolved 2 OutBack Power Systems Inc 2005 Sinewave Inverter Charger OutBack inverter chargers are the next _ TT generation in advanced power man E
11. 3 Off Grid Specifications Nominal DC Input Voltage Continuous Power Rating at 25 C AC Voltage Frequency Continuous AC RMS Output at 25 C Idle Power Full Search Typical Efficiency Total Harmonic Distortion Typical Maximum Output Voltage Regulation Maximum Output Current Peak RMS AC Overload Capability Surge 5 Second 30 Minutes AC Input Current Maximum AC Input Voltage Range MATE Adjustable AC Input Frequency Range DC Input Voltage Range Continuous Battery Charge Output Minimum Recommended DC Breaker Warranty Weight Unit Shipping Dimensions H x W x L Unit Shipping Grid Interactive Specifications Nominal DC Input Voltage Continuous Power Rating at 25 C AC Voltage Frequency Continuous AC RMS Output at 25 C Idle Power Full Search Typical Efficiency Total Harmonic Distortion Inverting Selling Output Voltage Regulation Maximum Output Current Peak RMS AC Overload Capability Surge 5 Second 30 Minutes AC Input Current Maximum AC Input Voltage Range MATE Adjustable AC Input Frequency Range DC Input Range Continuous Battery Charge Output Minimum Recommended DC Breaker Warranty Weight Unit Shipping Dimensions H x W x L Unit Shipping 4 OutBack Power Systems Inc Sealed Models FX2012T 12VDC 2000 VA 120 VAC 60 Hz 17 0 amps AC 20 Watts 6 Watts 90 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA 2500 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 10 5 to 17 5
12. 3200 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 10 5 to 17 0 VDC 125 amps DC OBDC 250 VFX3524 24 VDC 3500 VA 120 VAC 60 Hz 29 2 amps AC 20 Watts 6 Watts 92 2 5 2 70 amps AC 50 amps AC 6000 VA 5000 VA 4000 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 21 0 to 34 0 VDC 85 amps DC OBDC 250 VFX3648 48 VDC 3600 VA 120 VAC 60 Hz 30 0 amps AC 23 Watts 6 Watts 93 2 5 2 70 amps AC 50 amps AC 6000 VA 5000 VA 4000 VA 60 amps AC 80 to 150 VAC 54 to 66 Hz 42 0 to 68 0 VDC 45 amps DC OBDC 175 Standard 2 year Optional 5 year 61 Ibs 27 7 kg 64 Ibs 29 kg 12 x 8 25 x 16 25 30 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm Vented Models GVFX3524 24VDC 3500 VA 120 VAC 60 Hz 29 2 amps AC 20 Watts 6 Watts 92 2 lt 5 2 70 amps AC 50 amps AC 6000 VA 5000 VA 4000 VA 60 amps AC 80 to 150 VAC 58 to 62 Hz 21 0 to 34 0 VDC 85 amps DC OBDC 250 GVFX3648 48 VDC 3600 VA 120 VAC 60 Hz 30 0 amps AC 20 Watts 6 Watts 93 2 lt 5 2 70 amps AC 50 amps AC 6000 VA 5000 VA 4000 VA 60 amps AC 80 to 150 VAC 58 to 62 Hz 42 0 to 68 0 VDC 45 amps DC OBDC 175 Standard 2 year Optional 5 year 61 Ibs 27 7 kg 64 Ibs 29 kg 12 x 8 25 x 16 25 30 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm 2005 Mobile Specifications Nominal DC Input Voltage Continuous Power Rating at 25 C AC Voltage F
13. 40 is ready to install in your custom application Use for 120 or 240 VAC 60 Hz systems only Powering 240 volt items like deep well pumps with a single 120 volt inverter is possible thanks to the PSX 240 s step up capability Its step down feature allows you to charge your batteries with a 240 volt generator through a single 120 volt inverter The PSX 240 s ability to balance the output of series stacked inverter chargers makes it a critical item when using the OutBack stacking 120 240 VAC configuration The X 240 is also available without the enclosure for installation inside the PS2AC or PS4AC enclosures Step Up A __ _ gt gt Inverter Charger PSX 240 Step Down gt 120 240 VAC Generator PSX 240 Inverter Charger Generator Balancing 120 240 VAC Generator PSX 240 OutBack Balancing 120 240 VAC Generator Inverter Charger PSX 240 10 OutBack Power Systems Inc 2005 OO Stacking At OutBack we adhere to a philosophy that a power system should be fully customizable to address your specific needs Therefore we set out to create the world s only group of inverter chargers that use a truly modular architecture This modular architecture uses the next generation of a technique referred to as stacking to enable you to tailor your system for higher output power increased charging capabilities and or three phase power configuration Whether stacked in parallel classic se
14. AC 20 Watts 6 Watts 90 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA 3200 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 10 5 to 17 0 VDC 125 amps DC OBDC 250 VFX3524M 24VDC 3500 VA 120 VAC 60 Hz 29 2 amps AC 20 Watts 6 Watts 92 2 5 2 70 amps AC 50 amps AC 6000 VA 5000 VA 4000 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 21 0 to 34 0 VDC 85 amps DC OBDC 250 VFX3232M 32 VDC 3200 VA 120 VAC 60 Hz 26 6 amps AC 21 Watts 6 Watts 92 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA 4000 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 28 0 to 45 3 VDC 45 amps DC OBDC 175 Standard 2 year Optional 5 year 61 Ibs 27 7 kg 64 Ibs 29 kg 12 x 8 25 x 16 25 30 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm VFX2612E 12 VDC 2600 VA 230 VAC 50 Hz 11 3 amps AC 20 Watts 6 Watts 90 2 5 2 28 amps AC 20 amps AC 4600 VA 4000 VA 3100 VA 30 amps AC 160 to 300 VAC 44 to 56 Hz 10 5 to 17 0 VDC 120 amps DC OBDC 250 Vented Models VFX3024E 24VDC 3000 VA 230 VAC 50 Hz 13 0 amps AC 20 Watts 6 Watts 92 2 5 2 35 amps AC 25 amps AC 5750 VA 4800 VA 3300 VA 30 amps AC 160 to 300 VAC 44 to 56 Hz 21 0 to 34 0 VDC 85 amps DC OBDC 250 VFX3048E 48 VDC 3000 VA 230 VAC 50 Hz 13 0 amps AC 23 Watts 6 Watts 93 2 5 2 35 amps AC 25 amps AC 5750 VA 4800 VA 3300 VA 30 amps A
15. C 160 to 300 VAC 44 to 56 Hz 42 0 to 68 0 VDC 42 amps DC OBDC175 Standard 2 year Optional 5 year 61 lbs 27 7 kg 64 Ibs 29 kg 12 x 8 25 x 16 25 30 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm OutBack Power Systems Inc 5 Charge Controller MX60 The MX60 raises the bar for high performance solar controllers OutBacks ingenuity and engineering experience has been combined to maximize the output power of your expensive solar array Our real time active Maximum Power Point Tracking MPPT system ensures that your solar array is operating at its peak power point regardless of age shading or environmental conditions Systems with large solar arrays are now a snap thanks to the MX60 60 amp DC output current rating for 12 24 or 48 VDC systems all with just one product model Real wiring flexibility of your solar array is finally here because of the MX60 s wide range DC input up to 150 VOC The ability to step down a high voltage solar array to a low voltage battery can save you money by reducing the size of wire required and making the installation simpler and faster Our smart multistage recharging process ensures your batteries are recharged efficiently and gently to prolong battery life and achieves the highest possible performance All of the MX60 s status information is displayed on the large built in 3 1 8 cm backlit LCD screen Monitoring your solar arrays performance is easy because of included data loggi
16. C Powered Terminal and Ground Bus Bars Specifications Model Description GBB Ground Bus Bar not insulated TBB Terminal Bus Bar with black insulators TBB B Terminal Bus Bar with blue insulators TBB R Terminal Bus Bar with red insulators TBB W Terminal Bus Bar with white insulators Conduit Adapters Specifications Model Description ACA FX and VFX AC end DCA FX and VFX DC end Mounting Brackets Specifications Model Description PS2 CGB One MX60 PS2 CCB2 Two MX60s PS4 CCB2 Two MX60s OutBack Power Systems Inc 19 System Components PV Array Combiner Box h Ihe PSPV is a solar array combiner which can be used with a wide variety d E of system configurations and solar module types The PSPV is designed to Je provide NEC code compliant series over current protection of the wiring of multiple PV modules or subarrays for connection to charge controllers inverters or other systems components The rainproof aluminum enclosure is easily field configured to match your PV system design and amperage A requirements e Rainproof outdoor Type 3R powder coated aluminum enclosure e Approved for installation on both vertical and angled surfaces with a slope as little as 3 in 12 pitch also can be pole mounted Brackets not included e Designed for use with up to twelve OutBacks OBPV breakers for PV array configurations of 12 to 72 VDC systems maximum open circuit voltage of 150 VDC e Also can use the OutBack OBFH touch safe
17. CIutVsack Power Systems Powering the Planet One System at a Time Welcome Welcome to the fifth year of OutBack Power designing and manufacturing great products with you our custom ers in mind OutBacks ability to continuously innovate and lead the industry as well as listen to our customers has been a major influence in our success Since our last catalog OutBack has spent countless hours in research and development to engineer products at an elevated level of technological innovation Our efforts have resulted in new products and improved reliability Some of these new products include our vented higher power versions of our inverter chargers the world s most efficient grid interactive inverter charger a fully integrated grid interactive system and mobile inverter chargers for when you are on the move Despite our accomplishments we will not become complacent In 2005 we expect to maintain a steady growth and pioneer solutions to challenging problems and developing even more cutting edge power electronics We will continue to collaborate with our customers in order to develop our products and improve our industry leading technical support We are confident that OutBack is a company that is built to last and we would like to thank you for your continued support in powering the planet one system at a time History 2001 OutBack Power started by a passionate group of engineers whom wanted to bring power conv
18. Inverter Chargers 25 5 65 cm PS4 Mounting Plate Specifications Model Dimensions Unit H x W xD Dimensions Shipping H x W x D Weight Shipping PS4MP 25 5 x 38 3 x 3 65 x 97 x 8 cm 36 x 50 x 1 91 x 127 x3 cm 46 Ibs 21 kg 2005 OutBack Power Systems Inc 17 System Components OutBack AC Breakers Hydraulic Magnetic type breakers that are DIN rail snap in mountable and can be used for in put output or load circuits 1 2 13 mm wide OutBack DC Breakers Panel mounted Hydralic Magnetic type breakers which can be used for DC sources inverters or load circuits 3 4 18 mm wide OutBack PV Ground Fault Protection System The OBDC GFP 2 is required by the NEC for PV arrays mounted on residential dwelling roofs It can be used with the PS2DC PS4DC or PS1 An OBDC GFP 2 protects wiring and sys tem components for one or two PV arrays dual 80 amp PV circuits 150 VDC max VOC The OBDC GFP 2 system includes the GFP unit a ground bus bar neutral and ground connection wiring and mounting hardware 18 OutBack Power Systems Inc OutBack AC Breaker Specifications Model OBAC 50 OBAC 50D OBAC 50 3P OBAC 50DE OBAC 30 OBAC 30D OBAC 25D OBAC 20 OBAC 20D OBAC 15 OBAC 15D Rating 120VAC 120 240VAC 120 208VAC 240VAC 120VAC 120 240VAC 120 240VAC 120VAC 120 240VAC 120VAC 120 240VAC Version Single Pole Dual Pole Three Pole Dual Pole Single Pole Dual Pole Dual Po
19. d power save off on signals Interconnection cabling is standard Ethernet CAT5 with RJ45 modular jacks Through the use of a HUB your system is completely coordinated and managed by the MATE HUB Specifications HUB4 HUB10 Number of Ports 4 Plus MATE 10 Plus MATE Weight Unit 1 Ib 5 kg 1 Ib 5 kg Shipping 3 Ibs 1 4 kg 3 Ibs 1 4 kg Dimensions H x W x L Unit 10 5 x 6 25 x 1 27 27 x 16 x 3 cm 10 5 x 6 25 x 1 27 27 x 16x 3 cm Shipping 12x6x5 31x 15x 13cm 12x6x5 31x 15x 13cm 8 OutBack Power Systems Inc 2005 Remote Temperature Sensor RTS The OutBack Remote Temperature Sensor RTS is a necessary tool for proper battery charging All OutBack products with integrated battery charging have a temperature compensation system built in which benefits from the installation of the optional RTS The RTS ensures that your OutBack system knows the precise ambient tem perature so that it can recharge your batteries safely and efficiently Systems with multiple OutBack products connected to one HUB4 or HUB10 require only a single RTS to be installed 15 5 m cable Battery Charging Batteries are a key component in backup and off grid systems often serving as the only energy storage device To guarantee that they function properly it is important that your batteries are maintained A chief part of this maintenance is proper charging Your batteries should always be maintained above a 50 level of charge and recei
20. egulation settings will be reduced to prevent overcharging of the batteries Conversely in lower ambient temperature conditions the regulation settings will be increased to ensure complete recharging of the batteries Batteries are composed of a group of individual cells Through normal use the charge of each individual cell will not be equal to the other cells To address this your batteries should be EQUALIZED either once each month or once every few months depending on usage During the equalization charge the electrolyte in the battery is stirred up by gas bubbles which help to create an equal mixture of water and BULK aone SILENT FLOATTIME SILENT FLOATTIME SILENT acid Simultaneously the full cells are overcharged which allows the low cells to catch up and all of the active material in the battery to be reconverted to its charged state Depending on usage the hardened battery plate material that is no longer active in the bat tery sulfation can also be reduced by an equalization charge MATE Adjustable 2005 OutBack Power Systems Inc 9 Auto Transformer PSX 240 The OutBack PSX 240 auto transformer can be used for step up step down generator and split phase output balancing or as a series stacked inverter to load balancing auto former Incorporating a transformer with 120 volt 30 amp primary and secondary side a temperature activated cooling fan and a 25 amp dual breaker in a steal enclosure the PSX 2
21. ersion electronics technology into the 21st century This small startup quickly grew by offering innovative and well designed solutions to renewable energy problems OutBack listened to their customers and made many of the changes that were suggested creating a truly customer fo cused company in the power conversion electronics industry 2002 OutBack introduces its first sealed sinewave in verter charger the FX2024 with resounding success This single model changed the way people looked at system design by offering unprecedented flexibility in system design and expansion while the sealed construction allowed for uses which previously would have been considered too extreme for other inverter chargers OutBack releases the MX60 solar MPPT charge controller redefining performance and value This revolutionary product changed the way solar systems were being installed and quickly gained a reputation for get ting the most power possible from a PV array often making it more expensive to not use one 2003 OutBack launches the first of the vented versions of the FX series inverter chargers These VFX models were introduced in direct response to our customer s requests providing higher power at a similar price as the sealed counterpart OutBack launches the PS2 value priced system integration accessories This line of accessories addressed the needs of our customers for competitively priced system integration accessories f
22. inverter enters a power save mode which consumes as little as 3 watts saving your battery power for when you need it the most OutBack s innovative Maximum Power Point Tracking MPPT technology gets the most from your solar array or can also control hydro or wind turbine charging sources Complete system status and control is easily monitored by a single control instead of requiring the user to keep an eye on multiple displays and status indicators Grid Interactive Grid Interactive renewable energy systems enable you to demonstrate your personal commitment to a renewable energy future With the OutBack grid interactive system backup AC power is made available 24 hours a day in the event of a utility outage provid ing reliable power and peace of mind At night the inverters automatic power save mode ensures that energy is not wasted by needlessly charging your batteries from the utility grid An average conversion efficiency of 91 using the California Energy Commission CEC test protocol provides greater savings and a shorter time period for system payback OutBacks grid interactive technology provides you more than a typical solar inverter we also have an unmatched ability to utilize solar wind and hydropower sources Mobile and Marine OutBacks Mobile and Marine inverter charger models provide the high performance and reliability you need no matter where your travels take you Our die cast metal construction allows mounting in any
23. ithin 5 of the industry leading battery less grid tie inverter translating into more savings when using net metering The same field proven MPPT technology found in the MX60 solar charge controller is featured in the PS1 This cutting edge concept gives the system the ability to use your PV array at its peak output Uninterrupted AC power is provided by the PS1 s systems true sinewave inverter that has an industry leading California Energy Commission CEC certified efficiency of 91 thus guaranteeing that your household appliances run seamlessly while utilizing all available solar power Your recommended AGM batteries are maintained and charged by an innovative OutBack multistage charging process a valuable feature that assists in providing reliable backup power and a battery life up to 10 years An ultra fast 16 millisecond transfer switch guarantees that even sensitive backup loads such as computers never know when a grid outage occurs Like every OutBack Power product the PS1 is rugged All components are protected within an aluminum type 3R rainproof enclosure The ETL listed system is pre wired by OutBack engineers to ensure that the PS1 system works reliably for years to come A standard 5 year warranty provides peace of mind and satisfies state rebate requirements PS1 Specifications Model Description PS1 3000 Vented Inverter Charger with MX60 and HUB4 PS1 2500 Sealed Inverter Charger with MX60 and HUB4 PS1 BE Ba
24. le Single Pole Dual Pole Single Pole Dual Pole OutBack DC Breaker Specifications Model OBDC 250 OBDC 175 OBDC 125 OBDC 100 OBDC 80 OBDC 70 OBDC 60 OBDC 50 OBDC 40 OBDC 30 OBDC 20 OBDC 15 OBDC 10 OBDC 5 OBDC 1 Current Rating 250 amp 125 VDC 175 amp 125 VDC 125 amp 125 VDC 100 amp 125 VDC 80 amp 150 VDC 70 amp 150 VDC 60 amp 150 VDC 50 amp 150 VDC 40 amp 150 VDC 30 amp 150 VDC 20 amp 150 VDC 15 amp 150 VDC 10 amp 150 VDC 5 amp 150 VDC 1 amp 150 VDC Stud Terminal Size 3 8 stud 3 8 stud 5 16 stud 5 16 stud 5 16 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud 1 4 stud Width 0 5 13 mm 1 0 26 mm 1 5 39 mm A 26 mm 13 mm 26 mm 26 mm 13 mm A 26 mm 15 1 0 0 5 1 0 On 0 5 1O 0 5 13 mm 1 0 26 mm Width 1 5 39 mm 1 5 39 mm 1 0 26 mm 1 0 26 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm 0 75 19 mm OutBack PV Ground Fault Protection Specifications Model OBDC GFP 2 Description 80 amp at 150 VDC Stud Terminal Size 2 Poles Requires 3 2005 X 240 Auto Transformer The same auto transformer and breakers as the PSX 240 but designed to be housed within the PS2AC or PS4AC It can be used for step up step down generato
25. m 26 Ibs 12 kg PS4AC 60QE 60 amp 230VAC 50 Hz Bypass assembly 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12x 14x 21 31 x 36 x 53 cm 26 Ibs 12 kg PS4AC No bypass included 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12 x 14x 21 31 x 36 x 53 cm 24 Ibs 11 kg PS4DC 175 One 175 amp DC breaker 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12x 14x 21 31 x 36 x 53 cm 24 Ibs 11 kg PS4DC 250 One 250 amp DC breaker 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12x 14x 21 31 x 36 x 53 cm 24 Ibs 11 kg PS4DC No breakers included 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12 x 14 x 21 31 x 36 x 53 cm 22 lbs 10 kg OutBack PS4AC Bypass Assemblies Specifications for field installations in bare PS4AC version Model Inverter Output Bypass Breaker Input Breaker Output Breaker PS4 IOB 60Q 120 240 VAC 60 Hz 60 amps at 120 240 VAC Four 50 amps at 120 VAC Four 50 amps at 120 VAC PS4 10B 1000 120 240 VAC 60 Hz 100 amps at 120 240 VAC Four 50 amps at 120 VAC Four 50 amps at 120 VAC PS4 IOB 60QE 230 VAC 50 Hz 60 amps at 230 VAC Four 30 amps at 230 VAC Four 30 amps at 120 230 VAC PS4DC Breaker Configurations The PS4DC Breaker Panel has ten small 75 19 mm up to six medium 1 26 mm or four large 1 5 32 mm breaker positions The small sizes are 1 80 amps medium sizes are 100 or 125 amps an the large sizes are 175 or 250 PS4 Mounting Plate The PS4MP is a steel powder coated one part mounting plate for all your PS4 series accesso ries and up to four OutBack
26. mobile power system management are more quickly accessed A flush mount case design makes installation in boats and RVs more compact and attractive Communication with multiple products requires optional HUB 2005 MATE Specifications MATE MATE2 MATE2M Interface Display Control Keypad Status Indicators Communication Protocol Interconnection Cabling PC Computer Interface Microprocessor Set point and Data Memory Clock Calendar Environmental Rating Maximum Cable Length Warranty Weight Shipping Dimensions H x W x L Shipping pt O al MATE2 and MATE2M Surface mount with RS232 Grey Flush mount with RS232 Black Flush mount without RS232 Black 3 1 8 cm backlit LCD 6 backlit silicone keys dedicated inverter and AC input keys Two LED Status Indicators Proprietary OutBack Multi drop using an OutBack HUB4 or HUB10 Standard CAT 5 network cable with RJ45 modular jack 50 5 m included RS232 opto isolated DB9 jack 9600 baud serial communication 16 MHz low power consumption version 32K non volatile flash RAM On board real time clock with battery backup Indoor Type 1 1000 300 m Standard 2 year Optional 5 year 1 lb 5 kg 5 75 x 4 25 x 2 15x11x5cm OutBack Power Systems Inc 7 Communications Manager HUB The HUB system communications man agers are the backbone of your networked OutBack power conversion system The OutBack HUB communicates stacking load share an
27. n and power management components e ETLlisted indoor type powder coated steel enclosure with plenty of knockout and mounting provisions for a variety of OutBack products e Available without any DC breakers included PS4DC Order all required DC breakers separately e Also available with one inverter battery DC breaker included standard PS4DC 175 amp or PS4DC 250 e Space provided for up to four large breakers 175 or 250 amp or six medium breaker 100 or 125 amps can also be combined as two large and three medium breakers e Space provided for an additional ten small breakers 1 to 80 amps 150 VDC rated as well as the OutBack PV GFP 2 ground fault protection system e 500 amp 50 mVolts DC current shunt standard e One combined negative ground bus bar attached to the DC shunt included standard e One positive terminal bus bar TBB R for DC loads or PV array combining included standard e Can be used for negative or positive ground systems e Knockouts on five surfaces to facilitate conduit and inverter connections 16 OutBack Power Systems Inc 2005 PS4 Breaker Panel Specifications Model Standard Breakers Dimensions Unit H x W x D Dimensions Shipping H x W x D Weight Shipping PS4AC 600 60 amp 120 240VAC 60 Hz Bypass assembly 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12x 14x 21 31 x 36 x 53 cm 26 Ibs 12 kg PS4AC 100Q 100 amp 120 240VAC 60 Hz Bypass assembly 18 26 x 11 45 x 8 8 46 x 29 x 22 cm 12 x 14 x 21 31 x 36 x 53 c
28. ndard e Knockouts for battery conduit MX60 interconnect and stacking another PS2DC e Use for negative or positive ground systems e Knockouts on five surfaces to facilitate conduit inverter connections and additional MX60s Shown with DC breakers and DC GFP 2 order separately 14 OutBack Power Systems Inc 2005 PS2AC and PS2DC Breaker Panel Specifications Model Standard Breakers Dimensions Unit H x W x D Dimensions Shipping H x W x D Weight Unit PS2AC 50D 50 amp 120 240 VAC 60 Hz Bypass assembly 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15 x 12 56 x 38 x 30 cm 22 Ibs 10 kg PS2AC 50DE 50 amp 120 230 VAC 50 Hz Bypass assembly 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15 x 12 56 x 38 x 30 cm 22 Ibs 10 kg PS2AC No breakers included 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15x 12 56 x 38 x 30 cm 20 Ibs 9 kg PS2DC 175 175 amp DC Breaker 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15x 12 56 x 38 x 30 cm 22 Ibs 10 kg PS2DC 250 250 amp DC Breaker 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15x 12 56 x 38 x 30 cm 22 Ibs 10 kg PS2DC No Breakers included 18 5 x 11 5 x 9 47 x 29 x 23 cm 22 x 15x 12 56 x 38 x 30 cm 20 Ibs 9 kg OutBack PS2AC Bypass Assemblies Specifications for field installations in bare PS2AC version Model Inverter Output Bypass Breaker Rating Input Breaker Rating Output Breaker Rating PS2 IOB 50D 120 240 VAC 60 Hz 50 amps at 120 240 VAC 50 amps at 120 240 VAC 50 amps at 120 240 VAC
29. ng system that automatically records the last 64 days of system operation OutBack s network communication system allows your MX60 to communicate with the rest of your OutBack system eliminating multiple product interaction problems and allowing remote monitoring via the OutBack MATE display up to 1000 feet 300 meters away MX60 Specifications Nominal Battery Voltage Output Current Maximum Solar Array Size PV Open Circuit Voltage VOC Standby Power Consumption Charging Regulation Voltage Regulation Set points Equalization Voltage Battery Temperature Compensation Voltage Step Down Capability Power Conversion Efficiency Typical Status Display Remote Interface Data Logging Hydro Wind Turbine Applications Positive Ground Applications Operating Temperature Range Environmental Rating Conduit Knockouts Warranty Weight Unit Shipping Dimensions H x W x L Unit Shipping Use appropriate wire size in accordance with NEC 12 24 32 36 48 54 or 60 VDC Single model 60 amps maximum with adjustable current limit for smaller systems 12 VDC systems 800 Watts 24 VDC systems 1600 Watts 48 VDC systems 3200 Watts 150 VDC absolute maximum coldest conditions 135 VDC start up and operating maximum 1 Watt or less Five Stages Bulk Absorption Float Silent and Equalization 13 to 80 VDC User adjustable with password protection Up to 5 0 VDC above Absorb Set point Adjustable Timer Automatic Termination when
30. nit Shipping Battery Enclosure Weight without batteries Unit Shipping Certifications Anti Islanding Measures Warranty Field Installed Options 2005 Sealed Models PS1 2500 2500 VA 3000 VA 120 VAC 60 Hz 50 amps AC 16 amps AC with automatic back off 70 amps AC 50 amps AC 3300 watts DC stc rating 150 VDC 44 to 135 VDC Standard 80 amp DC 91 not CEC Certified 93 98 89 92 48 VDC 40 to 60 VDC 35 amps DC 60 amps DC 5 120 VAC 25 0 amps AC 20 8 amps AC 2 VAC THD lt 5 current THD per UL1741 conditions lt 16 Milliseconds Included 40 C to 60 C power derated above 25 C 4 kWHRS at 80 discharge Four AGM type 31 or type 27 sealed VRLA Optional MATE system display with RS232 port Powder coated aluminum stainless steel hardware Wall mount 16 on center studs 5 16 x 2 5 Lag Bolts three per side minimum 31 3 x 17 25 x 12 9 80 x 44 x 33 cm 40 5 x 20 5 x 17 25 103 x 52 x 44 cm 36 25 x 17 25 x 12 55 92 x 44 x 32 cm 43 25 x 20 25 x 16 75 110 x 51 x 43 cm 107 lbs 49 kg 117 lbs 53 kg 29 Ibs 13 kg 47 lbs 21 kg ETL certified to the UL1741 standard UL1741 compliant 5 year limited repair warranty standard MATE or MATE2 remote system display OBAC breakers for additional AC load circuits OBPV breakers for PV array series string protection Vented Models PS1 3000 3000 VA 3600 VA 120 VAC 60 Hz 50 amps AC 20 amps AC with automatic back off 70
31. onstruction 2005 uy ay T M ES A Wi a Sealed Inverter Chargers O The FX series is designed to survive in environments that would normally destroy other inverter chargers Protection for internal components is provided by our die cast aluminum chassis with a powder coated finish to prevent corrosion Internal and external cooling fins allow for passive heat transfer enabling peak operating efficiencies as high as 93 and looking cool while doing it Water and small particles are kept out through the generous use of gaskets and 0 ring seals on all seams and openings A protective conformal coating on all circuit boards provides the final line of defense against corrosion The now standard externally mounted TURBO cooling system improves performance in hot conditions VFX Vented Inverter Chargers The VFX series is designed for more protected installations By utilizing an efficient active cooling design the VFX models are available with AC output up to 3 6 kilowatts Our tough die cast aluminum chassis physically protects the internal components while the air intake includes an easily cleaned filter which allows for ventilation while also keeping bugs and other debris out All circuit boards are conformal coated to prevent corrosion from airborne moisture in humid conditions The now standard DC wiring cover DCC protects the DC terminals and battery cables from damage OutBack Power Systems Inc
32. or smaller systems 2004 OutBack releases the world s most efficient grid interactive inverter charger These models raise the bar for performance and value for battery connected grid interactive inverter charger systems OutBack introduces the PS1 fully integrated grid interactive power system This unique system sets a new standard for system integration performance and ease of installation in grid interactive applications 2005 What s new at OutBack Read these pages to find out Printed on Recycled Paper Copyright 2005 Index 3 Sinewave Inverter Charger 6 Charge Controller 7 System Display and Controller 8 Communications Manager 9 Remote Temperature Sensor 10 Auto Transformer 11 OutBack System Stacking 12 Grid Interactive System 14 System Accessories Design by Karen O Bryan Photography by Erik Stuhaug 18 6 System Components Charge Controllers 2005 OutBack Power Systems Inc 1 Off Grid Solar Wind Hydro Generator No matter what your energy source OutBacks products are engineered to provide your home or business with reliable electricity day in and day out The OutBack modular system architecture allows your system to grow along with your power needs up to 36 000 watts Power hungry appliances like washing machines air conditioning and power tools are easily started by our inverter s substantial surge power capability When not being used the
33. r and split phase output balancing or as a Series stacked inverter to load balancing auto former It can also transfer up to 2kW 3kW with the optional X fan kit from one side of the total power rating of the generator or the total power rating of an OutBack stacked series parallel 120 240 VAC inverter charger configuration X Fan Kit The X Fan Kit increases the power rating of the X 240 to a maximum of 6 kVA continuous Thermostatic controlled 120 VAC powered Terminal and Ground Bus Bars da Use for adding more wire terminations or for isolating r multiple positive negative cir eeeh cuits All TBB and GBB models have three 1 0 to 14 AWG and eight 6 to 14 AWG screw type ad en compression terminals which CCOO ee e means no ring lugs required Available with black white and red insulators The Battery Bus is 25 7 mm thick tin plated copper and can be mounted on the back plate of the PS2DC PS4DC or directly on the battery breaker terminals qt Conduit Adapters Allows connection of the FX and VFX inverter chargers to the PS2 and PS4 breaker panels or 2 conduit Mounting Brackets The mounting bracket allows MX60 charge controllers to be mounted on the side of the PS2DC or PS4DC enclosures 2005 X 240 Auto Transformer Specifications Model Description X 240 120 240 VAC 60 Hz 2 0 kW without Fan Kit 3 0 kW with X Fan Kit X Fan Kit Thermostatic controlled brushless fan 120 VA
34. requency Continuous AC RMS Output at 25 C Idle Power Full Search Typical Efficiency Total Harmonic Distortion Typical Maximum Output Voltage Regulation Maximum Output Current Peak RMS AC Overload Capability Surge 5 Second 30 Minutes AC Input Current Maximum AC Input Voltage Range MATE Adjustable AC Input Frequency Range DC Input Range Continuous Battery Charge Output Minimum Recommended DC Breaker Warranty Weight Unit Shipping Dimensions H x W x L Unit Shipping European Specifications Nominal DC Input Voltage Continuous Power Rating at 25 C AC Voltage Frequency Continuous AC RMS Output at 25 C Idle Power Full Search Typical Efficiency Total Harmonic Distortion Typical Maximum Output Voltage Regulation Maximum Output Current Peak RMS AC Overload Capability Surge 5 Second 30 Minutes AC Input Current Maximum AC Input Voltage Range MATE Adjustable AC Input Frequency Range DC Input Voltage Range Continuous Battery Charge Output Minimum Recommended DC Breaker Warranty Weight Unit Shipping Dimensions H x W x L Unit Shipping 2005 Sealed Models FX2012MT 12 VDC 2000 VA 120 VAC 60 Hz 17 0 amps AC 20 Watts 6 Watts 90 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA 2500 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 10 5 to 17 0 VDC 80 amps DC OBDC 250 FX2524MT 24VDC 2500 VA 120 VAC 60 Hz 20 8 amps AC 20 Watts 6 Watts 92 2 5 2 70 amp
35. ries series parallel or three phase there is always an inverter charger which performs the task of Master The Master talks to the other units through the HUB system communications manager while performing three major roles keeping all inverter chargers properly phased controlling inverter and charger output levels as well as putting unused inverters into Power Save mode to improve efficiency at low AC load levels Parallel Stacking More power at same output voltage When the inverter chargers are stacked in parallel all inverter and charger outputs are combined This means that each inverters AC output is added up to equal your total system AC output up to 36 000 watts in phase at the same 120 VAC 60 Hz or 230 VAC 50 Hz output voltage Charging output amperage is also combined in this same manner Load 3 kW 120 VAC 3 kW 120 VAC 3 kW 120 VAC Classic Series Stacking More power at higher output voltage Stacking inverter chargers in classic series provides a system with split phase 120 240VAC This method does not allow balancing between separate legs on a system and is can only be used in dual inverter charger systems without the X 240 Auto Transformer Load 3 kW 120 VAC 3 kW 120 VAC OutBack Series Parallel Stacking More power at all output voltages Series Parallel stacking or OutBack OB stacking is unique to OutBack inverter chargers Never before has it been possible to have inverter char gers balancing loads in
36. s AC 50 amps AC 6000 VA 4800 VA 3200 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 21 0 to 34 0 VDC 55 amps DC OBDC 175 FX2532MT 32 VDC 2500 VA 120 VAC 60 Hz 20 8 amps AC 21 Watts 6 Watts 92 2 5 2 56 amps AC 40 amps AC 4800 VA 4000 VA 2500 VA 30 amps AC 80 to 150 VAC 54 0 to 66 0 Hz 28 0 to 45 3 VDC 35 amps DC OBDC 125 Standard 2 year Optional 5 year 62 6 lbs 28 4 kg 67 Ibs 30 kg 13 x 8 25 x 16 25 33 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x 56 cm FX2012ET 12 VDC 2000 VA 230 VAC 50 Hz 8 7 amps AC 20 Watts 6 Watts 90 2 5 2 28 amps AC 20 amps AC 4600 VA 4000 VA 2500 VA 30 amps AC 160 to 300 VAC 44 to 56 Hz 10 5 to 17 0 VDC 100 amps DC OBDC 250 Sealed Models FX2024ET 24VDC 2000 VA 230 VAC 50 Hz 8 7 amps AC 20 Watts 6 Watts 92 2 5 2 35 amps AC 25 amps AC 5750 VA 4800 VA 3100 VA 30 amps AC 160 to 300 VAC 44 to 56 Hz 21 0 to 34 0 VDC 55 amps DC OBDC 175 FX2348ET 48 VDC 2300 VA 230 VAC 50 Hz 10 0 amps AC 23 Watts 6 Watts 93 2 5 2 35 amps AC 25 amps AC 5750 VA 4800 VA 3100 VA 30 amps AC 160 to 300 VAC 44 to 56 Hz 42 0 to 68 0 VDC 35 amps DC OBDC 100 Standard 2 year Optional 5 year 62 6 Ibs 28 4 kg 67 Ibs 30 kg 13 x 8 25 x 16 25 33 x 21 x 41 cm 21 75 x 13 x 22 55 x 33 x56 cm Vented Models VFX2812M 12 VDC 2800 VA 120 VAC 60 Hz 23 3 amps
37. series inverter chargers up to three MX60 charge controllers a MATE system controller and all the associated AC and DC components The OutBack PS2 series can be fully customized to your application and ordered pre wired or as individual components for field assembly PS2AC Breaker Panel The PS2AC is engineered to be a code compliant steel enclosure for AC power routing and management e ETL listed indoor type powder coated enclosure e Ground terminal bus bar bonded to cabinet e One white insulated AC neutral terminal bus bar e Two black insulated bus bars for Hot AC IN and OUT Leg 1 e Two red insulated bus bars for Hot AC IN and OUT Leg 2 i e Knockouts for eight additional OutBack AC load breakers e Provisions for mounting an X 240 and cooling fan e Knockouts on five surfaces to facilitate conduit and inverter connections Shown with 120 240 VAC 60 Hz dual inverter bypass 50D or 230 VAC 50 Hz dual inverter bypass 50DE and additional AC load breakers PS2DC Breaker Panel The PS2DC is a code compliant steel enclosure engineered to contain all DC power routing and management components e ETL listed indoor type powder coated enclosure with plenty of conduit knockouts e Knockouts for one additional inverter battery breaker and eight 3 4 19 mm breakers e 500 amp 50 mVolts DC current shunt standard e Battery negative ground bus bar standard e Battery positive bus bar for DC loads and PV arrays included sta
38. telligently between two legs of AC power while seamlessly changing between series and parallel OB Stacking uses the X 240 auto transformer to balance the loads between the two separate series legs of a system The X 240 allows AC loads on leg 1 and leg 2 to be powered by any combination of inverter chargers within your system Even if there are only two inverter chargers connected in series they can also func tion as if connected in parallel This allows larger AC loads to be operated by a system without risking overloading one of the 120 VAC outputs Load y or X 240 3 Phase Stacking More power for three phase loads Three inverter chargers can be configured to provide 120 208 VAC or 230 400VAC four wire Wye Star three phase AC Power An inverter charger is used to power each of the three legs for 3 phase AC power The loads on each of the inverters does not need to be kept balanced Load each phase is independently voltage regulated 3 kW 120 VAC or 2005 OutBack Power Systems Inc 11 3 kW 120 VAC 3 kW 120 VAC 3 kW 120 VAC 3 kW 120 VAC Grid Interactive System PS1 The PS1 is advanced engineering and refinement that you have come to expect from OutBack Power in a next generation grid interactive solar electric system The system s battery backup is a silent and hands off alternative to noisy and maintenance intensive generators In side by side real world testing the PS1 system performs w
39. ttery Enclosure with all cables Order batteries separately PS1 Options Model Rating Version Width OBAC 20 25 amp 120 VAC Single Pole OutBack 05 13 mm OBAC 15 15 amp 120 VAC Single Pole OutBack 05 13 mm Model Rating Version Width OBPV 8 8 amps 125 VDC Single Pole OutBack 05 13 mm OBPV 10 10 amps 125 VDC Single Pole OutBack 05 13 mm OBPV 15 15 amps 125 VDC Single Pole OutBack 05 13 mm 12 OutBack Power Systems Inc 2005 PS1 Specifications Continuous Power Rating At 40 C At 25 C AC Voltage Frequency Output AC Input Current Maximum AC Transfer Switch Battery Charger Maximum AC Surge Current Peak 1 millisecond RMS 5 seconds Maximum PV Array Wattage PV Open Circuit Voltage Maximum MPPT Input Voltage Range PV Array Ground Fault Protection Inverter Efficiency Typical Peak MPPT Efficiency Overall System Efficiency Typical Peak Battery Voltage Nominal Minimum maximum operating range Battery Charge Rate Inverter MX60 AC Output Voltage Regulation Typical Nominal AC Output Current Inverting Selling Total Harmonic Distortion Inverting Selling ACTransfer Switch Speed Typical Battery Temperature Sensor Operating Temperature Range Recommended Minimum Energy Storage Recommended Batteries Communications Enclosure Materials Mounting Recommended Mounting Hardware System Enclosure Dimensions H x W x D Unit Shipping Battery Enclosure Dimensions H x W x D Unit Shipping System Weight U
40. ve a complete recharge once a month to ensure operation at peak performance Prolonged use of the battery below a 50 state of charge will adversely affect the long term health of the battery and can result in premature failure The multistage charging process uses several regulation stages to allow fast recharging of the battery energy storage system while ensuring a long battery life high performance and efficient operation of the overall system The charging process begins with the BULK stage where maximum current is sent to the batteries until the target absorb voltage is reached and the absorb stage of the charge begins During ABSORB the charger provides the batteries with the just enough current to hold at the set voltage for a preset amount of time Following this cycle the charging system changes between available OutBack charging products Using the MX 60 the batteries enter the FLOAT stage where they are given a maintenance charge until there is no excess renewable energy The FX or VFX inverter charger will go into SILENT mode where the charger turns off until the battery voltage drops to the re float setting At this point the inverter charger initiates the maintenance FLOAT charge This method reduces fuel and utility consumption It should be noted that the temperature of your batteries has an impact on the charging process The OutBack RTS should be used to monitor this In higher ambient temperatures the battery charging r
Download Pdf Manuals
Related Search
Related Contents
Clarion NZ502 User's Manual Objectifs de la formation - IUT Génie Civil d`Amiens Manual de Instrucciones allcargo logistics limited bullsnu128b (Lecture seule) - SNUipp-FSU 76 - Seine Samsung DV4015J User's Manual Prime-Line D 1559 Instructions / Assembly Du pain et des liens - Association pour l`histoire des chemins de fer Copyright © All rights reserved.
Failed to retrieve file