Home
Opticon OPR 2001 User's Manual
Contents
1. Functions Menu labels Menu codes SET DIR Enable auto trigger PULL Enable auto trigger stand detection IHN k 4 END IM If the scanner is removed from the stand auto trigger is disabled and the scanner should be triggered manually 38 Opticon OPR 2001 Specifications Manual 15 1 2 Always Enable auto trigger all the time Functions Menu labels Menu codes SET DIR 7 Enable auto trigger IDN Disable auto trigger stand detecti Kb sable auto trigger stand detection HD END DIR 15 1 3 Manually Only trigger manually default Functions Menu labels Menu codes SET DIR Disable auto trigger III F Disable auto trigger stand detecti 5 sable auto tigger stand detection WD END DIR A magnetic switch and a magnet are used for stand detection operation Therefore auto trigger may be activated when there is a magnetic substance nearby 39 Opticon OPR 2001 Specifications Manual 16 Regulatory Compliance 16 1 16 2 16 3 16 4 Laser Safety JIS C 6802 2005 Class 2 IEC60825 1 A2 2001 Class 2 CDRH Class II Product Safety EN60950 1 2001 IEC60950 1 2001 EMC EN55022 EN55024 VCCI Class B This is a Class B product to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCC
2. 20 CTS Opticon OPR 2001 Specifications Manual b BUSY READY The scanner and the host computer notify each other of their state and whether they can receive data with BUSY READY through an RTS line They can communicate state to each other through a CTS line when connected as in the following figure Scanner Figure 12 Busy Ready communication The scanner stays ON is able to receive data except during certain parts of the process such as receiving data buzzer command execution transmitting data and menu processing The scanner checks the CTS line before transmitting data When it is ON the scanner transmits data When it is OFF the scanner waits for it to turn ON within a set time The scanner will abort transmission with an error indication buzzer when the CTS line is not ON within a specified period The Flow Control time outs are as follows and the default setting is indefinitely 10 Flow Control Time Out Menu Command Indefinitely 10 100 ms 11 200 ms D 400 ms ID ON RTS Cannot receive command gt ETS OFF ON b i b i i RS OFF i ON 7 i i i i gt RXD Decode VVattosend Send Wattosend Send finish Figure 13 Cannot receive command 21 Opticon OPR 2001 Specifications Manual CTS TXD signal timing When the CTS line RTS signal of the host is turned OFF while sending a TXD signal the scanner transmits one cha
3. Opticon OPR 2001 Specifications Manual All information subject to change without notice Document History Model Number OPR 2001 Specification Number S07011 Edition 1 Original Spec Number S06121 Date 2007 02 14 Copyright 2007 Opticon All rights reserved This manual may not in whole or in part be copied photocopied reproduced translated or converted to any electronic or machine readable form without prior written consent of Opticon Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT Serial Number A serial number appears on all Opticon products This official registration number is directly related to the device purchased Do not remove the serial number from your Opticon device Removing the serial number voids the warranty Warranty Unless otherwise agreed in a written contract all Opticon products are warranted against defects in materials and workmanship for two years after purchase Opticon will repair or at its option replace products that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental
4. UB KM ZZ can set the DOS V Wedge interface default b Notebook PC When not using external keyboard Reading menu barcodes ZZ UB KL ZZ can set the DOS V Wedge interface default 26 Opticon OPR 2001 Specifications Manual 8 3 2 Connectors a DOS V Host Connector Figure 20 DOS V host connector Contact Number Signal Name CPU_DATA NC GND vec CPU_CLK NC b DOS V Keyboard Connector 6 Figure 21 DOS V keyboard connector Oli AJOJN 3 D Ong al oo D Contact Number Signal Name KEY_DATA NC GND VCC KEY_CLK 6 NC Do not use the keyboard while the scanner is transmitting the data to the host Doing so may cause failure in data transactions oo BR wow hy 27 Opticon OPR 2001 Specifications Manual 9 Cable and Connector 9 1 RS 232C Cable Standard specification Type Straight Diameter 4 840 5 mm Length 1500 50 O mm Cores 6 insulated wires 1 conductive wire Weight Approximately 40 g D sub 9 pin Female 5 Voltage Class 2 50 1500 o Figure 22 RS 232C cable 9 2 USB Cable Standard specification Type Straight Diameter 4 8 0 5 mm Length 1500 50 O mm Cores 4 insulated wires 1 conductive wire Weight Approximately 40 g USB A Connector 1 n pel E 4 50 1500 o Figure
5. Flow control time out Indefinitely Signal Name I O RS 232C Level V Mark OFF Space ON TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 18 Specifications Manual Opticon OPR 2001 Specifications Manual 8 1 3 Pin Assignment Signal Pin Notes NC Open not connected Connected to pin 6 with jumper cable Connected to pin 4 with jumper cable Q Z el Did OO AJ OJNJ gt NC 9 Open not connected FG SHELL Shield Connector D sub 9 pin Female Power supply DC jack EIAJ voltage Class 2 8 1 4 Interface Circuit Host OPR 2001 zozeway oruajeamnbg DC INPUT Figure 8 Interface circuit 19 Opticon OPR 2001 Specifications Manual 8 1 5 Character Format Space TXD RXD LSB MSB Bars Start bit 1 Data bits 8 Stop bit 1 Figure 9 Character format same for both sending and receiving 8 1 6 Communication Format Transmitted data Decoded data Received oeta Figure 10 Communication format 8 1 7 Handshaking Select handshaking options using the menu or command listed below Handshaking Menu Command No handshake PO BUSY READY P1 MODEM P2 ACK NAK P3 ACK NAK NO RESPONSE P4 a No Handshaking The scanner attempts the communication regardless of the state of the host computer Scanner Figure 11 No handshaking
6. 23 USB cable 28 Opticon OPR 2001 Specifications Manual 9 3 Wedge Cable Standard specification Type Y cable Diameter 4 8 0 5 mm Length 1500 50 0 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 50 g Figure 24 Wedge cable 9 4 Connector Specification Scanner Side CN1 12 pin Pin No RS 232C USB Wedge 1 GND GND GND 2 RXD 3 TXD 4 CTS 5 RTS 6 NC 7 NC DATA KEY_CLK 8 NC Data KEY_DATA 9 NC CPU_CLK 10 NC CPU_DATA 11 VCC VCC VCC 12 FG shield FG shield FG shield 29 Opticon OPR 2001 Specifications Manual 10 Default Settings 10 1 Barcodes Scan the following menu barcodes to return to the default settings RS 232C Default Functions Menu labels Menu codes SET PUTT AMT AT a H Z RS232C OTI SS uU 2 H Z USB HID Default Functions Menu labels Menu codes SET DUNN USB HID INN S END DUNN USB VCP Default Functions Menu labels Menu codes SET DUNN use com HUNN SC END DUNN Wedge Default with external keyboard Functions Menu labels Menu codes SET MAU AMT ARTA AT wedge default i S with keyboard MN MNM S END MAU ONA ANN TN a 30 Opticon OPR 2001 Specifications Manual Wedge Default withou
7. 5 EE UE 10 E DE 10 52 USB Wedge tectum eden Nocatee sine tam ee Ee eege Ee 10 6 Optical Speller SES 11 6 1 Laser Scanning Specifications xxsscecccdcccaavesavnareriacestdcadascadadveadcxeannuudieueonmadaraed Meeadateeenters 11 6 2 aech eege 11 6 2 4 Laser scanning HE ics anand did alld hie ee Oise ins Gees 11 6 2 22 Scanning el 11 7 Technical Specifications tsa ase cs cased eee accede ec calcd 12 7 1 Print Contrast Signal PCOS siccsvctssecictnatisnsslcaveisibindiaesndemsecancuenactsdaehisatinldacadanunigesenadaiatens 12 7 2 Scan Area and Resolution siscsnisccsciccniacssnvcaatdeconthceweedantadontwcateecanayansuucen terernmearncacannenantes 13 To Piti Skew and HUE 14 Ole Pith e EE 14 7 3 2 Skew Angle and Dead Zone stnan nnen nnen nnen nn nnt 15 L e Ge Ki Le ue EE 16 TAx CUNA eenegen tances 17 8 Interface Specifications ie sisicscscceccesescesecapacccetaesacre cansesascaeniscinein EES EES EES 18 8 1 RS 232C Interface cccccccccecccneceaeceaeeeaeeeaeeeaaeeaaeeaaeeaaecaaeeaaeeaaaeaaaeaaaeaaaeaaaeaaaeeaaaaaaaaaea 18 8 1 1 Settings and Communication 18 8 1 2 Le ENEE 18 8 1 3 Pin ASSIQGNMENL A 19 8 1 4 Interface Cirount ESSEEN SEESSEENSEESSEEN SEEEN SEENSEEE SEEE SE EE EEEE EEEE 19 8 15 Character Formatai a aA A eee 20 8 1 6 Communication FOM Atsine eia ie deeded de nates 20 Opticon OPR 2001 Specifications Manual G de lee DE le DEE 20 8 2 USB Interface Specifications 0c cccc
8. Voltage 5 0 V Direct light or specular reflection light from a source should be prevented from entering the acceptance area 9 Opticon OPR 2001 Specifications Manual 5 Electrical Specifications 5 1 RS 232C Parameter Symbol Min Typ Max Unit Notes Power supply voltage Von 45 6 0 6 5 V Operating current lop 90 150 mA No buzzer Peak current IPEAK 550 600 mA Standby current IPRE 35 70 mA Startup time Tp 100 ms 5 2 USB Wedge Parameter Symbol Min Typ Max Unit Notes Power supply voltage Von 4 5 5 0 5 5 V Operating current lop 90 150 mA No buzzer Peak current IpEAK 450 500 mA Standby current Joer 35 70 mA Startup time Tp 100 ms Conditions e Connect 10 resistance to a power supply line in series and measure the current by the voltage between both ends of resistance e Power supply voltage is measured at a connector terminal area e The current value depends on the interface type and host computer to which the device is connected 10 Opticon OPR 2001 Specifications Manual 6 Optical Specifications 6 1 Laser Scanning Specifications Parameter Specification Unit Light emitting element Red laser diode Emission wavelength 650 10 25 C nm Light output 1 0 or less mW Scanning method Bi directional scanning Scanning speed 100 20 scans s Scan angle Scan angle 54 5 R Read a
9. the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal weight in the European Union 34 Opticon OPR 2001 Specifications Manual 13 Durability 13 1 Electrical Noise No malfunction occurred when sinusoidal electrical noise 10Hz 100kHz lt 0 1Vpp was added to a power supply line Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 90 mm Angle a 0 B 15 y 0 Curvature R Power Supply Voltage 5 0V 13 2 Shock 13 2 1 Drop Test without packaging No malfunction occurred after the following drop test Drop Test Drop the scanner from a height of 150 cm onto a concrete floor three times on each of 5 sides 150 cm Figure 26 Drop test 13 2 2 Drop Test with individual packaging No malfunction occurred after the following drop test Drop Test Drop the scanner from a height of 150 cm onto a concrete floor on each of one corner three edges and six sides 10 drop tests in total 35 Opticon OPR 2001 Specifications Manual 13 3 Vibration Strength No malfunction occurred after the following vibration test Vibration Test Increase the frequency of the vibration from 10 Hz to 100 Hz with acce
10. ELECTRONICS Test Sample Distance Label Angles Curvature 70 mm from the front edge of the scanner Pitch Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Pitch angle Skew angle B 15 Tilt angle y 0 Tilt angle Pitch angle a 0 Skew angle B 15 Skew angle Dead zone Pitch angle a 0 Tilt angle y 0 R 16 Opticon OPR 2001 Specifications Manual 7 4 Curvature With 8 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20mm V Barcode Figure 7 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Distance 70 mm from the front edge of the scanner Angle Skew Angle B 15 17 8 Interface Specifications 8 1 RS 232C Interface 8 1 1 Settings and Communication Reading menu barcodes ZZ U2 ZZ can set the RS 232C interface default You can change the communication condition using the menu barcode 8 1 2 Signal Level Item U2 setting Baud rate 9600 BPS Start stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake
11. I If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Compliance to ROHS RoHS The restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC 40 17 Safety Handle this product carefully Do not deliberately subject it to any of the following 17 1 Shock Do not throw or drop the scanner Opticon OPR 2001 Specifications Manual Do not place heavy objects on the cables 17 2 Temperature Conditions Do not use the scanner at temperatures outside the specified range Do not pour boiling water on the scanner Do not throw the scanner into the fire Do not forcibly bend the cables at low temperatures 17 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 17 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not use the scanner near a radio or a TV receiver It may cause reception problems The scanner may be damaged by
12. N UPC EAN all add on Chinese Post Matrix 2 of 5 Codabar NW 7 including ABC and CX Code 11 Code 39 Normal Code 39 Full ASCII Code 39 Italian Pharmaceutical Code 93 Code 128 EAN 128 Composite Codes UCC EAN 128 incl CC A B C IATA Industrial 20f5 Interleaved 20f5 ISBN ISMN ISSN Korean Postal Authority code Matrix 20f5 MicroPDF417 MSI Plessey UK Plessey PDF417 RSS RSS 14 incl CC A B RSS Limited incl CC A B RSS Expanded incl CC AIB S Code Telepen Tri Optic Opticon OPR 2001 Specifications Manual 3 Physical Features 3 1 Dimensions W 151 0 x D 56 0 x H 30 5 mm 3 2 Weight 60 grams max excluding cable weight 4 Environmental Specifications 4 1 Operating Temperature and Humidity Temperature 5 to 50 C Humidity 20 to 85 RH 4 2 Storage Temperature and Humidity Temperature 20 to 60 C Humidity 10 to 90 RH Opticon OPR 2001 Specifications Manual 4 3 Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light 3 000 Ix Fluorescent light 3 000 Ix Sunlight 50 000 Ix Laser Axis Ce Figure 1 Ambient light immunity Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 70 mm Angle a 0 B 15 y 0 Curvature R Power Supply
13. cccccccceccceccceeeeeeeeaeceaeceaeceaeceaeceaeeeeeceaaeeeaeeeaeeeaeeaas 25 EN ENT dn Le EE 25 Ce ET CEET 25 8 2 3 Interface e re DT 26 8 3 DOS V Wedge Interface Specification cccccceeeeeecccceeeeeeeneeeseeceneneeeeseenseseneneeeeeeeees 26 SO SUNOS EE 26 8 3 2 e ET CET 27 9 Gr 0 E gt 1 e al EE 28 9d TR TE 28 Ge E 28 DiS NWS ee 29 9 4 Connector Specification Scanner Side c ccesssececceeeeeeeeeesseecceeneeeeeeeeeeeensneneeeeees 29 10 D fault la CN 30 10 1 lee EEN 30 10 2 Default Settings 1 Readable CGodes eEEEESSRSESRREEEEEEEEEREEEEEREEEEEEEEEEREEEERREEEEEEEEEE ENKEN 31 10 3 Default Settings 2 Read Options Trigger Buzzer ccc eeeceeeeeeeeeeeeeteeeeeeeeeeeeeeenaaaees 33 BA Tell NUVI G s asacsncc tess a cece cei ee cheat waste ceee beens dees cane anntcacat exten dieseed cacndacehicenbat cenit EATA TEERAA ani 34 12 Packaging Specifications E 34 12 1 Individual Packaging Gpechficaton reerreerreenrreerrenrnenn nenen nen enne 34 12 2 Collective Packaging Specification 2 ccs ececceceeeeeeeeeeceeee sneer seeeneeneeeseneeeeeteeeeeseneneee 34 13 E UL 35 E E Electmical e EE 35 VA Et 35 13 2 1 Drop Test without pockaging asai a ai iiaa 35 13 2 2 Drop Test with individual packaging 35 13 3 TE E e LE 36 DUAN Electricity E 36 13 9 Dust and Drip Proot is eegen ege EEN distended eae eds 36 13 6 Gable Strengt EE 36 DT Cable Pulling TeSt sicinval iis bites im iin ee
14. damages arising out of use or inability to use both the hardware and software even if Opticon has been informed about the possibility of such damages Packaging The packing materials are recyclable We recommend that you save all packing material to use should you need to transport your scanner or send it for service Damage caused by improper packaging during shipment is not covered by the warranty Trademarks Trademarks used are the property of their respective owners Opticon Inc and Opticon Sensors Europe B V are wholly owned subsidiaries of OPTOELECTRONICS Co Ltd 5 3 Tsukagoshi 5 chome Warabi shi Saitama Japan 335 0002 TEL 81 0 48 446 1183 FAX 81 0 48 446 1180 SUPPORT USA Europe Phone 800 636 0090 Email support opticonusa com Email support opticon com Web www opticonusa com Web www opticon com 2 Opticon OPR 2001 Specifications Manual Contents TT E 7 WU TE 7 se Eelst E E 8 SG Neil 8 3 2 WA e E 8 4 Environmental Specifications i vivian sievecensecceieaenececeneaceeceneeanensnsnceeneeetsencnecaenatbatetaeaaceecnseasseeties 8 4 1 Operating Temperature and Hummidity 2 ccceccceeceeeeeeseesenene cece ee eeeeeesesneneeeeeeeeeeeeesces 8 4 2 Storage Temperature and Humidity civavecccecdsisedesasdedesixseietavesdepssacedscdeedededdidenctneceetieinediecs 8 4 3 Ambient Light Immunity cccsccccscrcotsiccartteanabcancecataxtasnvadouabieteeeereesadnuaioncecotexrauzancteccetanionttaads 9
15. e a eee ee 36 13 6 2 Cable Tail Bending Test 36 T4 TE E 37 15 Auto Trigger Optlon Kees eeeeegbeegeneegE eessen 37 Opticon OPR 2001 Specifications Manual 15 1 Auto viele TE E 38 15 D Stand OMY EE 38 e RE 39 RE EI UE 39 DE Crip En 40 ER EE 40 16 2 ee EE 40 16 3 EE 40 16 4 Compliance to ROHS 0 cccccccceceeeeeeeeeeeeeeeee ee ee eee eee nnen eee eee eeeeeeeeeeeeseeeseeeeeeeeeeeeseeeeeees 40 BLY gt EE 41 Eeer eeh 41 17 2 Temperature COnditions ssis rieri i eri e a e EPERE EEE AE OE E EASE EEE 41 17 34 Foreign EC ia aieia e a AE Raada T a Ea e ariani 41 IT A eu 41 18 Mechanical ED AW NENG ee 42 Table of Figures Figure 1 Ambient light immunity E 9 Figure 2 Laser scanning tilt and curvature ssesessesssssseeiiirettteterrtrritttteeesitrintnnnnsssttnnnnnnnnnnae 11 Figure 3 Depth eg DE 13 Figure 4 PICH enccccstnccratsicccrwntaevidnetcesucnassdicedessblncentsanenruans E eo e a aiaa RE GAENE EAEE Eiaa 14 Figure 5 Skew angle and dead zone eEEEEEEERERRREEEEEEEEEEEEERRREEEEEEEEEEEEEERRRREREEEEEEEEEEEEEEERRREEE NEE 15 Figure 6 Tang Eisai aannaaien AA Aaaa Ea 16 Fig re E inie ae alae te rte hac ne aa edn EE 17 ee E US Cn EE 19 Figure 9 Character format same for both sending and receiving ceceeeeeeeeettteeeeeeeeeeeeeeeee 20 Figure 10 Communication Bei 20 Figure 11 No TANS Le EEN 20 Figure 12 Busy Ready communication chicccsssscccuchtisndeiaseianideradeanimvialdncieiathisaelececbdbacad
16. ection from the surface when the auto trigger is used Auto trigger distance 50 10 mm from the edge of the scanner Conditions Moving Speed 100 10 mm s the moving direction is not specified Angle Skew angle excluding Pitch Angle and Dead Zone specified in section 7 3 Pitch Skew and Tilt Environmental Temperature and Room temperature and humidity Humidity Environmental Illuminance 500 to 900 Ix Conditions for the auto trigger 1 Barcode sheet OPTOELECTRONICS Test Sheet white Background OPTOELECTRONICS Test Sheet black 2 Barcode sheet OPTOELECTRONICS Test Sheet black Background OPTOELECTRONICS Test Sheet white Background Auto Trigger Point Barcode Sheet Figure 28 Auto trigger operation 37 Opticon OPR 2001 Specifications Manual Auto trigger can be enabled in 2 ways e Stand detection mode This option enables auto trigger automatically in case the scanner is inserted into the stand e Normal auto trigger mode Descriptions in show menu IDs Enable auto trigger Normal Mode Auto trigger enabled all time YES Stand Detection Mode Auto trigger is enabled only when the scanner s set into the stand Is the scannerset in the stand Auto Trigger Mode Manual Trigger Mode Figure 29 Trigger options 15 1 Auto Trigger Settings 15 1 1 Stand Only Enable auto trigger only when the scanner is inserted into the stand
17. he Reading column m means Enable reading and X means Disable reading e In the Transmit code length column m means Transmit code length and X means Do not transmit code length e Inthe Transmit CD column m means Transmit check digit and X means Do not transmit check digit e Inthe Calculate CD column m means Calculate check digit and X means Do not calculate check digit e means not supported e Inthe Prefix column means there is no prefix setting 32 10 3 Default Settings 2 Read Options Trigger Buzzer Specifications Manual Item Default Setting Setting the number of characters Fixed length OFF all codes Read mode Single read Multiple read reset time 500 ms Add on wait time 500 ms Multiple columns read Disabled Default option X0 setting Read 1 times redundancy 0 Other options X1 X3 setting BS BW setting Redundancy Trigger switch Read n times redundancy n 1 for following symbologies and lengths e Code39 with length lt 5 e MSI Plessey with length lt 4 e IATA Industrial 20f5 Interleaved 20f5 with length lt 8 e Matrix 20f5 amp Chin Post Scode with length lt 8 e Codabar NW7 with all lengths e Code 11 with length lt 5 Enabled Trigger repeat Disable trigger repea
18. iantechs 21 Figure 13 Cannot receive command EEN 21 Figure 14 Signal EE 22 Figure 15 ee GE ELE ER et E 23 Figure 17 ACK NAK No response cccceeeeeeeeeeeeeceeeeeeenenensaneneeeeeeesenseseeeeaeeseeeeeeeeeseeees 24 Figure 18 USB A COMMON eege eecht 25 ere CA le EE 26 Figure 20 DOS V host connector s2cccscccucticsataytantxcoadovdaeazasteucetnndentadeanxsdnimueseexeengvaauancotteienteeamnaee 27 Figure 21 DOS V keyboard CONnNMC E 27 Figure 22 RS 232C e VE 28 Figure 23 USB cable eebe eher eege ere 28 Opticon OPR 2001 Specifications Manual Figure 24 Wedge Cable i carntuscccrtousadatdi ccaencaniiialshaasbbtaahendauacdeubncaphdeareonsuancenehceanbenaneasanceiotniiancnes 29 Figure 25 Serial number diagram EEN 34 ele RTE 35 Figure 27 Cable tail bending fest 36 Figure 28 Auto trigger operation BEE 37 Figure 29 Migger OOO EE 38 Figure 30 Mechanical dt eugge desse Eege Ee ENEE EEE Ee 42 Opticon OPR 2001 Specifications Manual Abstract This manual provides specifications for the OPR 2001 laser barcode scanner Overview The OPR 2001 is a handheld laser barcode scanner The use of a short wavelength red laser beam enhances visibility when scanning lines The OPR 2001 can be configured to scan both positive and negative barcodes Scanned data is transferred via an RS 232C USB or Wedge interface Auto trigger settings are available The OPR 2001 complies with RoHS Supported symbologies JA
19. lerated velocity 19 6m s 2G for 60 minutes in non operating state Repeat this routine in each X Y Z direction once for 60 minutes each 13 4 Static Electricity Air discharge 10 kV Max No malfunction 15 kV Max No destruction Measurement environment Use electrostatic testing device compliant with IEC 61000 4 2 Discharge resistance 330 Q Capacitor charging 150 pF 13 5 Dust and Drip Proof IEC IP42 13 6 Cable Strength 13 6 1 Cable Pulling Test No malfunction occurred after the following pulling test Pulling test Fix the scanner and pull the cable with the force of 2 5 kg 24 5N for 1 second Repeat 20 times 13 6 2 Cable Tail Bending Test No malfunction occurred after the following bending test Bending test Fix the scanner and attach a weight of 500 grams 4 9N swing the cable back and forth at an angle of 90 Repeat it 1 000 000 times 500 gf 4 9 500 gf 4 9N Figure 27 Cable tail bending test 36 Opticon OPR 2001 Specifications Manual 14 Reliability MTBF Mean Time Between Failures of this product is 10 000 hours The estimate of MTBF is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock Auto Trigger Option The product has an optional auto trigger setting which starts barcode reading automatically by using sensor detection The scanner starts barcode reading after detecting refl
20. ngle 44 Min e 6 2 Laser Scanning Standard 6 2 1 Laser Scanning Tilt Scanning tilt is the vertical difference between the ends of a laser scan line e Up to 0 92 in a vertical direction from the scan origin mirror motor mirror e Up to 2 46 mm when measured at 150 mm from the scan origin Measurement is done at the center of the laser scan line 6 2 2 Scanning Curvature Scanning curvature is the maximum difference between the laser scan line and the line between the ends of the laser scan line e Upto 1 17 in a vertical direction from the scan origin mirror motor mirror e Up to 3 06 mm when measured at 150 mm from the scan origin Measurement is done from the center of the laser scan line CH oi ZS amp oO Figure 2 Laser scanning tilt and curvature 11 Opticon OPR 2001 Specifications Manual 7 Technical Specifications The conditions for technical specifications are as follows unless otherwise specified in each section Conditions Ambient temperature and humidity 21 C 70 F 60 RH Ambient light 500 to 900 Ix Background Barcode black Space white Margin white Background of label black Power supply voltage 6 0 V RS 232C 5 0 V USB Wedge Decoding test Approve the performance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 seconds or less 7 1 Print Contrast Signal PCS 0 45 or higher o
21. racter and waits When the CTS signal is turned ON while transmitting a character the character will be transmitted TXD Lot Ton nd n 2 n 2 CTS Figure 14 Signal timing Note When using loopback wire connection for RTS CTS line of the scanner in this setting No handshake is not enabled c MODEM The scanner turns CTS line ON before transmitting data Other processes are the same as BUSY READY ON RTS gt Transmit data EE OFF ON TXD j i RSR EITE IRXD Decode Wattosend Send Wattosend Send fnish Figure 15 Modem transmit data 22 d ACK NAK Opticon OPR 2001 Specifications Manual After data has been transmitted the scanner expects to receive one of the following responses from the host e ACK response Action The scanner completes transmission with the good read buzzer and returns to the initial state e NAKresponse Action The scanner sends the data again and waits for the response from the host e DC1 response Action The scanner returns to waiting for the trigger if it has a trigger the initial state e None response Action The scanner sounds the error buzzer and returns to the initial state ACK NAK timeout can be set as follows using the menu or commands ACK NAK Timeout Menu Command Indefinitely default X14 100 ms XI5 500 ms Al6 1000 ms XI7 GOOD READ Buzzer Figure 16 ACK NAK 23 Opticon OPR 2001 Specifica
22. t Auto trigger Disable auto trigger Margin check Margin check normal Buzzer duration Buzzer tone 50 ms 3 kHz single tone Buzzer loudness Loud Maximum Buzzer timing Buzzer before transmission Startup buzzer Enable startup buzzer Indicator duration 200 ms 33 Opticon OPR 2001 Opticon OPR 2001 Specifications Manual 11 Serial Number The serial number as shown below is affixed to the scanner A LASER RADIATION L NM DO NOT STARE INTO BEAM E A OtSAPsIICL JFAW PFUE JSC8802 2005 Madmum output 1 0mW CLASS 2 LASER PRODUCT IEC80825 14A22001 Wavelength 650nm Complies with 21 CFR 1040 10 and 1040 11 except for dewations pursuant to Laser Notice No 50 dated July 26 2001 OPR 2001 FC Manufactured MmmmmmmYYY Y N SN ANN OPTOELECTRONICS CO LTD WARABESHISAITAMA MADE IN JAPAN gt Production Date Serial Number Figure 25 Serial number diagram 12 Packaging Specifications 12 1 Individual Packaging Specification Put the scanner in a protective foam bag and place it in a single packing box Size of the package after assembly 245 W x 110 D x 40 H mm 12 2 Collective Packaging Specification Put 50 individually packaged OPR 2001 scanners in a collective packaging box Dimensions 650 mm W x 550 mm D x 250 mm H Note The RO mark labeled on the package tray or package box guarantees that
23. t external keyboard Functions Menu labels Menu codes ne 2 eeso Wl oe mm 10 2 Default Settings 1 Readable Codes Symbology Read Transmit Transmit Calculate Set Set Others Code CD cD Prefix Suffix Length UPC A a X a a CR UPC A Add on X X a a CR UPC E a X a a CR UPC E Add on X X a a CR EAN 13 a X a a E CR EAN 13 Add on X X a a CR EAN 8 a X a a CR EAN 8 Add on X X a a _ CR Chinese Post Matrix X X a X ER CR 2of5 Code 11 X X X a CR Code 39 a X a X CR Not transmit ST SP Code 39 Trioptic a X CR Not transmit ST SP Code 93 a X X a CR Code 128 a X X a CR EAN 128 X X X a CR IATA E X a X SC CH 31 Opticon OPR 2001 Specifications Manual Symbology Read Transmit Transmit Calculate Set Set Others Code CD cD Prefix Suffix Length Industrial2of5 a X a X CR Interleaved2o0f5 a X a X CR Korean Postal Code X X X a B CH Code 3of5 Matrix2o0f5 x X a X CR MicroPDF417 x Xx SS CR MSI Plessey el X mCD1 SCD CR NW 7 CODABAR el X E X CR Not transmit ST SP PDF417 X xX _ _ CR RSS 14 X X E el CR RSS limited X X E el CR RSS expanded X X a a CR S Code a X a X _ CR Telepen a X X a SE CR UK Plessey a X a a CR Notes e In t
24. tions Manual e ACK NAK NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the same as ACK NAK GOOD READ Buzzer Figure 17 ACK NAK No response 24 Opticon OPR 2001 Specifications Manual 8 2 USB Interface Specifications 8 2 1 Settings a USB HID Reading menu barcodes ZZ SU ZZ can set the USB HID interface default The OPR 2001 USB model uses a full speed USB interface b USB VCP Reading menu barcodes ZZ C01 ZZ can set the USB VCP interface default The OPR 2001 USB model uses a full speed USB interface Note You must install the USB VCP driver on the host 8 2 2 Connectors a USB A connector 1 Cesta BROWN A Figure 18 USB A connector Contact Number Signal Name VCC DATA DATA AJOJN GND 25 Opticon OPR 2001 Specifications Manual 8 2 3 Interface Circuit Full Speed USB Transceiver amp Buffers Equivalent to NFM21PC104RE Equivalent ta 467 500 Figure 19 Interface circuit Do not use the keyboard while the scanner is transmitting the data to the host Doing so may cause failure in data transactions 8 3 DOS V Wedge Interface Specification 8 3 1 Settings a Desktop PC When using external keyboard Reading menu barcodes ZZ
25. ver 70 of reflectivity of space and quiet zone 12 Opticon OPR 2001 Specifications Manual 7 2 Scan Area and Resolution The scan area is a circular area centered around the beam which appears at various resolutions 500 350 200 100 70 403020 in millimeters Resolution 0 127 Resolution 0 15 Resolution 1 0 Figure 3 Depth of field Resolution Symbology PCS Quiet Zone Digits Depth of Field mm 1 0mm CODE 39 0 9 25 mm 1 40 to 500 0 5 mm CODE 39 0 9 18mm 3 20 to 350 0 25 mm CODE 39 0 9 10 mm 8 20 to 200 0 15 mm CODE 39 0 9 7mm 10 20 to 100 0 127 mm CODE 39 0 9 5mm 4 30 to 70 Conditions Barcode Sample OPTOELECTRONICS Test Sample N W Ratio 1 2 5 Angle a 0 8B 15 y 0 Curvature R 13 Opticon OPR 2001 Specifications Manual 7 3 Pitch Skew and Tilt 7 3 1 Pitch Angle Scanning performance is guaranteed when a 35 Figure 4 Pitch 14 Opticon OPR 2001 Specifications Manual 7 3 2 Skew Angle and Dead Zone Scanning performance is guaranteed when skew angle B lt 50 Excluding dead zone Dead zone B 8 There are some areas in which decoding fails due to specular reflection Figure 5 Skew angle and dead zone 15 7 3 3 Tilt Angle Scanning performance is guaranteed when y lt 20 Opticon OPR 2001 Specifications Manual Conditions Figure 6 Tilt angle Barcode Sample OPTO
26. voltage drops The scanner may not perform properly in environments when placed near a flickering light such as a computer monitor television etc 41 Opticon OPR 2001 Specifications Manual 18 Mechanical Drawing Dimensions 151 0 mm x 56 0 mm x 30 5 mm except protruding parts o 2 E 2 Er 2 Q o o a Kal H a E D O N O N D Ki Ka o E 3 Qa I o Ki Figure 30 Mechanical drawing 42