Home

Omron Healthcare M7 User's Manual

image

Contents

1. e It is recommended to have the OMRON M7 inspected every two years to ensure correct function and accuracy Consult your OMRON retail outlet or OMRON distributor as mentioned on the packaging M7 English Replace cuff e Remove the air plug to re use it with a new cuff Replace batteries e Remove the battery out of the battery compartment and insert four new identical 1 5V batteries type AA Spare parts e Due to high company quality standards OMRON considers the main unit as a non serviceable part because of the need for proper calibration after replacement of high tech components Attention Disposal of batteries and the OMRON M7 should be carried out in accordance with the national regulations for the disposal of electronic products xX 9 Technical data Product name Model Display Measurement range Accuracy Inflation Deflation Pressure detection Memory Power supply Battery life Operating temperature Humidity Operating environment Storage temperature Humidity Weight Outer dimensions Accessories Optional parts Note e Manufacturer EU representative OMRON Digital Automatic Blood Pressure Monitor M7 Digital LCD Pressure 0 299 mmHg Pulse 40 180 minute Pressure 3 mmHg Pulse 5 of display reading Automatic inflation Fuzzy control Automatic air release by controlled air release valve Electrostatic capacity pressure sensor 90 Measurements 4 x 1 5V ba
2. air plug in air jack 3 5 Fit cuff 1 2 cm les a wv 1 Bare your arm 2 Open the cuff with right hand and cover the cuff Caution Push up your sleeve avoid constricting over your left upper arm the blood flow Caution Do not inflate the cuff when not wrapped around the arm M7 English RR Note keep marked edging on the inside of your Note for right arm use keep the tube under your elbow joint elbow and parallel with your little finger Note keep the tube even with your middle finger R 3 Hold the cuff wrap it around your arm Caution Be sure the cuff fits closely do not pinch your arm 4 Operation 4 1 Measurement Q Systolic blood pressure in mmHg R Diastolic blood pressure in mmHg S Heart symbol flash measurement takes place light up measurement finished T Battery exhausted batteries are weak exhausted U Inflation cuff inflates and measurement starts V Deflation measurement finished and cuff deflates D W Memory stored measurements displayed X Average average value of last 3 measurements displayed Y Pulse heartbeats per minute Z Date time Lo man 00 03 4 i M7 English Caution Allow an interval of at least three minutes between two successive measurements 1 Sit comfortably at a table with your feet flat on the 2 Relax your arm and turn your palm upward floor and rest your arm on the table Caution Cuff at heart heig
3. M7 English Introduction The OMRON M7 measures your blood pressure and pulse simply and quickly from the arm without the use of an inflation bulb or stethoscope The measurement values are stored in the memory of the OMRON M7 The OMRON M7 includes the standard cuff for arm circumferences ranging from 22 to 42 cm Table of contents 1 How to obtain meaningful blood pressure 4 1 Measurement 7 readings 2 4 2 Read display 9 2 Overview 3 5 Memory 10 3 Preparation 4 5 1 Recall previous values 10 3 1 Insert the batteries 4 5 2 Erase memory 11 3 2 Control functions 4 6 Storage 12 3 3 Set date and time 5 7 Error causes and rectifications 13 3 4 Connect cuff 6 8 Maintenance and spare parts 14 3 5 Fit cuff 6 9 Technical data 14 4 Operation 7 10 General information about blood pressure 15 Digital Automatic Blood Pressure Monitor Ne Instruction manual page 1 A Good ee or Meali M7 English 1 How to obtain meaningful blood pressure readings General e This manual contains important information for safe use of the OMRON M7 Follow this manual to prevent wrong measurement values injury and damages e The OMRON M7 is not suitable for measuring the frequency of cardiac pacemakers e Consult your doctor during pregnancy arrhythmia and arteriosclerosis as this can influence the measurement e Avoid eating drinking alcohol smoking doing sports and taking a bath before measurement e Be calm and relaxed before a
4. doctor for detailed medical examination You can assist the treatment prescribed by your doctor in the following ways e Loose weight and lower your cholesterol level by reducing the calories and fat in your diet Cut down on animal fats and eat more fruit and vegetables e Reduce the consumption of alcohol e Reduce the intake of salt the German League for Combating High Blood Pressure recommends six grams of salt per day i e one teaspoon on average e Stop smoking e Take regular exercise e Monitor your blood pressure Upper curve systolic blood pressure Lower curve diastolic blood pressure en ee pe 6 12 18 24 Time of day Example fluctuation within a day male 35 years old 16
5. ht during measurement OMRON M7 Ip melts dps elli nes OMRON M7 dpustte 3 Press on off button Caution Wait for zero and the heart symbol to continue Caution Do not remove cuff during inflation OMRON M7 OMRON M7 dens sli omron M7 denis omron M7 dps Hi NY ES 4 Press start button and release within 3 seconds Note the unit inflates the cuff If required the unit automatically increases the pressure by 30 mmHg Caution Sit still do not move or speak M7 English GP uelli UP s nse 4 M gt omron M7 paste Apli OMRON M7 prai Se 2e un Ti U DATE TIME SET 5 If your systolic blood pressure is known to be more than 220 mmHg press and hold the start button until the monitor inflates 30 or 40 mmHg higher than your estimated systolic blood pressure Caution Do not apply more pressure than necessary The monitor will not inflate above the 300 mmHg 4 2 Read display OMRON M7 YAris DD 5 LJ 18 00 1 Read values of blood pressure and pulse from 2 Note values in your personal blood pressure pass displays M7 English OMRON M7 3 Press on off button to turn off power Note power automatically switches off after 5 minutes 5 Memory 5 1 Recall previous values omron M7 GO neti W Memory stored measurements displayed 1 Press on
6. igh blood pressure e Overweight e High cholesterol level Severe hypertension Moderate hypertension Mild hypertension Normal systolic value Diastolic blood 80 85 gt pressure 90 mmHg 100 110 According to the blood pressure classification by the WHO ISH 15 e Smoking e Excessive alcohol consumption e Stress and emotional upset e Excessive consumption of salt e Lack of physical exercise e Genetic hereditary predisposition e Underlying illnesses such as kidney disorders or endocrine disturbance Blood pressure measurement Measuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment The oscillometric method of measurement determines your blood pressure by measuring the pressure fluctuations caused by the pulse waves Since your blood pressure fluctuates within a day see graphic next page you should always measure it at the same time each day to ensure that the measurements are genuinely comparable At the doctor s surgery nervousness and tension may 200 gt 150 F mmHg 50 F M7 English cause your blood pressure to be higher than in familiar circumstances at home This is known as White Coat Hypertension Treatment of high blood pressure If your blood pressure reaches upper values of 140 160 mmHg and lower values of 90 95 mmHg in repeated measurements over several days you should consult your
7. nd during measurement e You should never change the dose of medicines prescribed by your doctor e Store the OMRON M7 in a dry closed place with a temperature between 20 C and 60 C e Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more Tips for use e Check your blood pressure at least twice a day before breakfast after work e Use the OMRON M7 only for yourself e Measure your blood pressure before taking an antidepressant e Do not discard the air plug e When using the AC adapter keep the batteries in the main unit e Use both the AC adapter and the batteries to extend battery life e Do not measure your blood pressure while you are in a vehicle e Always measure on the same arm e Wrap the cuff around your arm before start of measurement Caution e Only the OMRON M7 cuff can be used on this device Other cuffs must not be attached e Operating temperature between 10 C and 40 C e Operating environment must be free from excessive vibrations shocks electrical noise corrosive gas etc e Stay out of sunlight during measuring e Keep portable phones 5 meters away during measurement e Do not wrap the cuff around any object other than your arm e Do not fold or crush the cuff and the air tube e Do not drop the OMRON M7 2 Overview A Display blood pressure B Display pulse date and time C Memory buttons W A D Date time setting button E Start bu
8. oduced by contraction of the heart muscle The diastolic blood pressure value lower pressure or lower value represents the blood pressure produced by relaxation of the heart muscle Classification of blood pressure The World Health Organisation WHO and the Inter national Society of Hypertension ISH developed the blood pressure classification This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital Systolic blood pressure mmHg A 180 160 140 130 Normal blood pressure 120 0 Optimal blood pressure target value Health and blood pressure The incidence of hypertension increases with age In addition a lack of exercise excess body fat and high levels of cholesterol LDL which sticks to the inside in blood vessels reduces elasticity of these vessels Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction For these reasons it is very important to know whether the blood pressure is within a healthy range Blood pressure fluctuates from minute to minute throughout the day Therefore it is essential to take regular measurements to help you identify an average blood pressure Symptoms of high blood pressure High blood pressure can go unnoticed for a long time since it does not cause noticeable symptoms The following are all possible causes of abnormally h
9. off button to turn on power X Average average value of the last 3 measurements Caution Wait for zero and the heart symbol to displayed continue omron M7 Auski 85 2 Press memory button A Note display shows average value of last 3 blood pressures and heartbeats 10 M7 English OMRON M7 dp mets OMRON M7 dp nets OMRON M7 dp ste IVP ase Psie Psie 144s onde NHA 86 86 Chad EB 7 3 Press memory buttons V A for latest and Note display shows alternately date and time of previous values measurement Press on off button to turn off power Note keep memory buttons V A pushed to fast forward 5 2 Erase memory Apii O I 1 Press on off button to turn on power Caution Wait for zero and the heart symbol to continue omron M7 pins m omron M7 barge START el 2 Press memory button VW and start button simultaneously to erase memory Note press memory button VW first because the start button will start inflation Caution All stored values will be erased Press on off button to turn off power AP telle 11 6 Storage 1 Slightly fold air tube and insert in cuff 2 Put cuff and main unit in storage case Note do not disconnect air tube e Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more e Store the OMRON M7 in the carton in a dry closed place with a temperature between 20 C and 60 C 12 7 E
10. rror causes and rectifications Indication Error pn E E Incorrect inflation eN Correct E measurement not possible p E e Abnormal Er memory function Low voltage DI Display empty No data in memory Inexplicable values Cause Movement Movement sound Incorrect fastening cuff Operation start button for more than 3 seconds Cuff leaks air Cuff pressure too high Batteries weak exhausted AC adapter disconnected Unplugged AC adapter without batteries Wrong working method M7 English Rectification Repeat measurement If necessary hold start button to inflate manually Follow instructions repeat measurement Fit new cuff Follow instructions repeat measurement Consult your OMRON retail outlet or distributor Fit four new identical 1 5V batteries type AA follow instructions Connect AC adapter correctly follow instructions Fit four new identical 1 5V batteries type AA Follow instructions repeat measurement 13 8 Maintenance and spare parts Cleaning instruction e Use a soft dry cloth to wipe stains from the OMRON M7 e Use a soft slightly moistened cloth and soap to clean main unit and cuff of the OMRON M7 Caution Do not use petrol thinners or similar solvents Caution Do not wash the cuff e Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging Calibration
11. tteries type AA AC adapter optional part New batteries will last for approximately 300 measurements 10 C to 40 C 30 to max 85 relative humidity Free from excessive vibrations shocks magnetic fields electrical noise etc 20 C to 60 C 10 to max 95 relative humidity Main unit approximately 400 g excluding batteries cuff approximately 130 g Approximately 165 mm W x73 mm H x 110 mm D cuff approximately 150 mm W x 582 mm L arm circumference 22 cm to 42 cm Cuff model HEM CUFF P hard case instruction manual guarantee card blood pressure pass AC adapter extended tube Subject to technical modification without prior notice CE o9 OMRON HEALTHCARE Co Ltd 24 Yamanouchi Yamanoshita cho Ukyo ku Kyoto 615 0084 Japan OMRON HEALTHCARE EUROPE B V Kruisweg 577 NL 2132 NA Hoofddorp This device fulfils the provisions of the EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems M7 English 10 General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen Blood pressure is the pressure exerted on the arteries The systolic blood pressure value higher pressure or top value represents the blood pressure pr
12. tton J Air plug F On off button K Air jack G Cuff L Battery compartment H Air tube 3 Preparation 3 1 Insert batteries 1 Slide off the battery cover 2 Insert four batteries as indicated in the battery compartment and close compartment Caution Use four identical 1 5V batteries type AA 3 2 Control functions A Display blood pressure B Display pulse date and time C Memory buttons V A D Date time setting button E Start button F On off button 3 3 Set date and time At the first time you set the OMRON M7 the factory settings 12 00 1 1 2003 will be displayed Another time the actual date and time will be displayed Note use the grey coloured button to carry out the instruction omron M7 ip vedic OMRON MZ WD uch 1 Press on off button 2 Press date time setting button for 2 seconds to proceed to year setting Note use a thin stick to press date time settings button omron M7 drugs Jroen M7 pastis x Djv I 7D ome In START 200 Oo BEJLI 3 Press memory buttons V A to set the year Note if display reaches 2030 it will return to 2003 Note keep memory button down to fast forward Press date time setting button to proceed to date setting lll Wp tele putte i Apsis Apsis or 4 Use memory buttons W A and date time setting button to set successively month hour and minutes 3 4 Connect cuff P Air jack 1 Insert

Download Pdf Manuals

image

Related Search

Related Contents

Rexel REM820  アンテナ一体型ETC取付ステー 組付・取扱説明書  Bali Cut-to-Size 76-8205-923-20x48 BO WHITE VINYL CUT Installation Guide  Franke 112.0047.840  Samsung IMPRESORA MULTIFUNCION LASER MONOCROMO SCX-4825FN Manual de Usuario    Paganini DAC User Manual v1.2x  Samsung Corby manual do usuário    Bedienungsanleitung/Garantie Bar-Mixer / Milchaufschäumer BM  