Home
Omron Healthcare HEM-757 User's Manual
Contents
1. Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le ministre des communications 14 CARE AND MAINTENANCE To protect your monitor from damage please AVOID the following e Subjecting your monitor to extreme temperatures humidity and direct sunlight e Folding the cuff and tubing tightly e Inflating the monitor over 280 mmHg e Disassembling the monitor e Subjecting the monitor to strong shocks for example dropping the monitor on the floor e Do not clean the monitor with volatile liquids THE MONITOR SHOULD BE CLEANED WITH A SOFT DRY CLOTH FIVE YEAR LIMITED WARRANTY Your HEM 757 Intellisense Automatic Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of five years under normal use The five year warranty excludes the monitor cuff The cuff is warranted for a one year period This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit prepaid to Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Attn Service Dept together with 5 00 for return shipping and insurance Be sure to include the model number of your unit and your phone number on any correspondence We will either repair or replace at our option
2. before taking a measurement 2 Put your left arm through the cuff loop making sure that the bottom edge of the cuff is approximately one half inch above the elbow 3 Pull the end of the cuff so that the entire cuff is evenly tightened around your arm and press the sewn hook material firmly against the pile side of the cuff Make sure that your skin will not be pinched in the D ring once you inflate the cuff bladder Immediately deflate the cuff bladder and readjust the cuff if skin becomes pinched 4 Sit in a chair with your feet flat on the floor and place your left arm on a table so that the cuff is at the same level as your heart 5 Press the ON OFF button 6 After the Heart Symbol 9 appears next to a zero on the digital panel press the START button 7 Remain still throughout the entire reading 8 When measurement is complete the monitor alternately displays your blood pressure and pulse on the digital panel and automatically deflates the cuff 9 Wait 2 3 minutes before taking another blood pressure measurement You may require more rest time between readings depending on your individual physiological characteristics BATTERY INSTALLATION REPLACEMENT 1 Slide the battery cover off in the direction of the arrow 2 Install or replace 4 AA size batteries so positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover 4 lf the L
3. free of charge any parts necessary to correct defects in the materials or workmanship The above warranty is complete and exclusive The warrantor expressly disclaims liability for incidental special or consequential damages of any nature Some states do not allow the exclusion or limitation of incidental or consequential damages so the above warranty may not apply to you Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state As a condition to operation of your warranty the enclosed registration card must be completed and sent to us within 10 days from the date of purchase FOR CUSTOMER SERVICE CALL TOLL FREE 1 800 634 4350 16 SPECIFICATIONS Model HEM 757 Display LCD Digital Display Measurement Range Pressure 0 to 280 mmHg Pulse 40 to 180 minute Accuracy Calibration Pressure 3 mmHg or 2 of reading Pulse 5 of reading Inflation Automatic by electric pump Deflation Automatic deflation system Rapid Pressure Release Active electromagnetic control valve Pressure Detection Electrostatic capacity type pressure sensor Measurement Method Oscillometric method Pulse Wave Detection Capacitive pre
4. Omron HEM 757 Intellisense Automatic Blood Pressure Monitor Although your blood pressure fluctuates throughout the day no self adjustment is necessary as the monitor intelligently adjusts to your changing conditions The Intellisense monitor uses fuzzy logic intelligence to sense both your systolic and diastolic blood pressure values and the result is personalized inflation with every reading Arm discomfort and misreading due to improper cuff inflation are virtually eliminated Your new OMRON monitoruses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading At the push of a button the monitor automatically fills the cuff with air and displays your systolic diastolic and pulse measurements on an extra large display panel Please read this instruction manual thoroughly before using the Omron IntelliSense Automatic Blood Pressure Monitor For specific information on your own blood pressure CONTACT YOUR PHYSICIAN KNOW YOUR UNIT IntelliSense Progress Indicator Systolic Blood Pressure Display START Button Memory Call Button Pulse Display Diastolic Blood Pressure Display Air Plug Connects to the air jack Arm Cuff Air Tube Green Cuff Marker 4 Carrying Case QUICK REFERENCE GUIDE 1 Avoid eating smoking and exercising for at least 30 minutes
5. ARM CUFF 1 Insert the air plug of the arm cuff into the air jack of the monitor 2 The cuff should be assembled correctly when it is removed from the box If it is not pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop 3 If the cuff is assembled correctly the sewn hook material material will be on the outside of the cuff loop and the metal D ring will not touch your skin 4 Put your left arm through the cuff loop The bottom of the cuff should be approximately 1 2 above the elbow The cuff tubing should be positioned along the ce Cuff Tube middle of the inside of Guft Tab your arm as shown 5 Pull the cuff so that the top and bottom edges are tightened evenly around your arm 6 N oc oO HOW TO APPLY THE ARM CUFF When the cuff is positioned correctly press the sewn hook material FIRMLY against the pile side of the cuff The cuff should be wrapped so that it fits snugly and stays in place You should be able to fit one finger between the cuff and your arm Sit in a chair with your feet flat on the floor and rest your arm on a table so that the cuff is at the same level as your heart Relax your arm and turn your palm upward Be sure there are no kinks in the air tubing HOW TO TAKE A READING Please read A Few Suggestions Before Blood Pressure Measur
6. OMRON INSTRUCTION MANUAL siie Automatic Digital Blood Pressure Monitor with IntelliSense Model H E M 757 TABLE OF CONTENTS TEC CUI reee a a nance iea EEN e E a Sa ee 1 Know Yo r Uniti eesriie a e acta an 2 Quick Reference GUIGG is5 ieee eee as ee tetas Sk ee ee i ito 3 Battery Installation Replacement cccceeeeeeeeeneeeeeeeeeeeeeeeeeeeees 4 Suggestions Before Blood Pressure Measurement c cccceee 5 How to Apply the Arm Cuff a cece ceeceeeeeeeeeeeeceeeeeeeeeeeaaeeeeeeeeeeeeaees 6 7 How to Take a REAdING cceeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeeeeees 8 9 10 How to Use the Memory FUN Ction cc ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 How to Use the Optional AC Adapter cccsseeceeeeeeeeeeeeeeees 12 Tro bleshootinNg eeren ndaste anes oa E EE aay 13 A AN Uicntetira cua E E ET EE A apneic EEE 14 Care and MaliInenanGecnccincisteinicesatssetaeiathoreisivathistieteiaicase titles 15 Five Year Limited Warranty cccceeeeeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeees 16 Specification Ss nesen san Aeon EEE a 17 INTELLISENSE blood pressure monitor is a global brand name of blood pressure monitor equipped with bio information sensing and high performance fuzzy logic technology which are the key technologies of OMRON With this excellent sensing technology the monitor can achieve accurate measurement INTRODUCTION Thank you for purchasing the
7. e ON OFF button The monitor will stop inflating and start deflating rapidly then the monitor will power off 10 HOW TO USE THE MEMORY FUNCTION How to Use the Memory Function This monitor has the function to store fourteen measurement values Push the Button while a 9 mark is displayed e Maximum of fourteen stored measurement values can be called out e For the fifteenth measurements and after the values from the oldest measurement will be deleted gt gt an AGD AGG amp GE Previous value Value before Value of the previous fourteen measurement measurements before If you want to delete all the stored data You can delete all the stored data while the mark is displayed Push these two buttons at the same time Display of memory deletion 11 HOW TO USE THE OPTIONAL AC ADAPTER ACCESSORY ITEM SOLD SEPARATELY When using AC power use only the exclusive AC adapter Model HEM ADPT1 which can be purchased from Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Toll Free Phone 1 800 634 4350 Insert the AC adapter plug into i oe the jack on the side of the gt monitor Insert the AC adapter plug into a 120V AC outlet 50 60 Jack cycles Option AC Adapter To remove the AC adapter disconnect the adapter plug from the AC outlet first and then disconnect the cord from the monitor s jack To avoid possible damage to the m
8. ement and How To Apply The Arm Cuff before taking a reading 1 Press the ON OFF Button oc Ju me a All display symbols appear for oo I IO approximately one second This oc alae is the initial LCD test ti a A a A r G b The display symbols disappear i and the Deflation Indication 88 i55 Initial LCD Test Symbol starts to flash _ c When the monitor completes the necessary preparations before measurement the Heart Symbol 9 appears next to a zero NOTE Wait for the Heart Symbol Q before taking a measurement 2 Press the START button As the Q cuff begins to inflate the mm IntelliSense monitor automatically determines your ideal inflation level During this process the Intellisense symbol will be flashing on the display Because this monitor detects the pulse even during inflation do not move your arm and remain still during the measurement W Deflation Indication lt a Ready to Measure Display of measurement process a A 5 mark indicates the measurement process When the Start Button is pushed a amp mark flushes Inflation started HOW TO TAKE A READING 3 The IntelliSense Progress Indicator will flash on the display showing that the monitor s fuzzy logic intelligence is determining your personal measurements NOTE Because blood pressure is being measured even during deflation it is important to remain still until the reading is fully comp
9. leted Display of measurement process amp A mark indicates the measurement process During the inflation a amp mark turns on During the deflation a mark E T turns on and one each mark 1 I turns off with the progress of mn approximately every 1 3 of the l m al oe process 4 When the measurement is 55 complete a Heart Symbol v flashes and the arm cuff deflates wm 5 At the end of the measurement ne your blood pressure and pulse nm are alternately displayed wc 6 Press the ON OFF button to turn the monitor off NOTE If you forget to turn the monitor off the monitor will automatically power off after five minutes 4 HOW TO TAKE A READING Special instructions regarding the inflation of the IntelliSense Monitor 1 In rare circumstances the user s physiological characteristics may require a higher level of inflation These circumstances may include weak pulse or an unusually high systolic blood pressure When this occurs the monitor may reinflate to a value of about 30 mmHg higher than the previous inflation value Reinflation occurs only once 2 If your systolic pressure is known to be more than 220 mmHg push and hold the START button until the monitor inflates 30 to 40 mmHg higher than your suspected systolic pressure Continue to press button NOTE Do not apply more pressure than necessary 3 If you want to stop the measurement push th
10. onitor use only the exclusive AC adapter Model HEM ADPT1 available from Omron Healthcare Inc Other adapters may vary in output voltage and polarities AC Adapter Output _ e _ 6 V 500 mA NOTE The monitor is designed not to draw power from the batteries when the AC adapter is in use 12 TROUBLESHOOTING Error Indicator Cause Correction Cc Cc _ co TIO as Cuff under inflated Wait 10 minutes before taking we another measurement Repeat m v steps listed under How to Take a Reading If EE is displayed again take another measurement by l pressing and holding the START Movement during ated as listed in step Z nger m m measurement ow to Take a Reading Os Cr Z Cuff over inflated more than Carefully es and repeat steps listed under How to Take a i 300 mmHg Reading gt g C cy L x Battery voltage is excessively Replace all four AA batteries with low new batteries l crs Trouble caused by abnormal a ee ie wh re you memory function ave purchased this unit or the nearest OMRON dealer If you continue to have difficulty obtaining a reading call OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1 800 634 4350 Please tell the representative you have an OMRON Model HEM 757 13 CAUTION CAUTION Changes or modifications not expressly approved by Omron Healthcare Inc could void the user s authori
11. ow Battery Indicator appears on the display replace all four batteries Long life alkaline batteries are recommended g Remove the batteries if the monitor will not be used for an extended period of time SUGGESTIONS BEFORE BLOOD PRESSURE MEASUREMENT 1 Avoid eating smoking and exercising for at least 30 minutes before taking a measurement Also rest for at least 5 minutes before taking a reading 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 Remove tight fitting clothing from your left upper arm 4 Measurement should be taken in a quiet place and you should be in a relaxed seated position Rest your left arm on the arm of a chair or on a table so that the cuff is at the same level as your heart 5 Remain still and do not talk during the measurement 6 Keep a record of your blood pressure and pulse measurements for your doctor Remember a single measurement does not provide an accurate indication of your true blood pressure You need to take and record several measurements over a period of time Try to measure your blood pressure at the same time each day for consistency Blood pressure measurements fluctuate considerably 7 Wait 2 3 minutes between successive measurements Waiting allows the engorged blood vessels to return to normal You may require more rest time between readings depending on your individual physiological characteristics HOW TO APPLY THE
12. ssure sensor Power Source 4 AA batteries or AC adapter sold separately Battery Life Approximately 300 uses Operating Temperature Humidity 50 F to 104 F 10 C to 40 C 30 to 85 RH maximum Storage Temperature Humidity 4 F to 140 F 20 C to 60 C 10 to 95 RH maximum Console Weight Approximately 19 oz 530 g not including batteries Outer Dimensions Approximately 4 1 2 I x 7 w x 2 5 6 h 115 mm x 177 mm x 72 mm Cuff Dimensions Approximately 5 1 2 x 19 140 mm x 480 mm Accessories Arm cuff carrying case instruction manual NOTE These specifications are subject to change without notice 17 TITLE For Customer Service Call Toll Free 1 800 634 4350 Manufactured by OMRON Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 www omron com ohi Copyright 2000 OMRON HEALTHCARE INC 2 000000 0X 18
13. ty to operate this product NOTE POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the product and receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications