Contents
1. 4396976 4371923 4471385 4120583 4435732 4672457 4739396 Limited One Vear Warrantv VOUR OMRON MODEL HEM 713C Digital Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of one year under normal use This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit and receipt as proof of purchase prepaid to OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 together with 5 00 for return shipping and insurance We will either repair or at our option replace free of charge any parts necessary to correct defects in material or workmanship The above warranty is complete ad exclusive The warrantor expressly disclaims liability for incidental special or consequential damages of any nature Some status do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Any implied warranties arising by operation of law shall be limited in duration to the term of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state As condition to operation of your warranty the enclosed registration card must be completed and sent to us within 10 days from the date of purchase Cau
2. ausing equipment standard entitled Digital Apparatus ICES 03 of the Canadian Department of Communications Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le materiel brouilleur Appareils Numeriques NMB J03 ildictee par le ministre des communications Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 OMRON 0692581 7 A OMRON uses recycled paper to help preserve our natural recources 13
3. OMRON Instruction Manual Automatic Digital Blood Pressure Monitor Model HEM 703CP HEM 703CP xxxx 0692581 7 A important Thank vou for purchasing our Digital Blood Pressure amp Pulse Monitoring Kit Please care fully read this instruction manual before use and keep it with vour portion of the enclosed warrantv card PLEASE NOTE 1 Allow 3 to 5 minutes between blood pres sure readings on same arm Repeated mea surement results in inaccurate readings 2 Keep in mind only a physician can ac curately determine safe or unsafe limits of blood pressure This instrument should be used by non professional persons only to determine measurement of blood pres sure not to make any medical judgement Remember blood pressure varies during the day This unit is a precision instrument avoid rough handling direct sunlight high tem perature humidity and magnetic field Fold ing or bending cuff may result in damage to cuff Do not inflate cuff above 280 mmHg Do not take unit apart You cannot calibrate unit If you have any difficulties or problems with unit contact our Service Center 1 800 634 4350 CONTENTS Imp rtant okie okt chee ae a 1 Name and Function of Each Part 2 Preparations for Use 3 Instructions for Use 8 When Error Indication Symbols Appear 10 Specifications Name and Function of Each Part Svstolic Bood Pressure Displav y Diast
4. Set the Printing Paper Please be sure not to print without inserting printing paper as it will shorten the life span of the printer head 1 Slide the plastic printer cover in the direction indicated bv the arrow svmbol and remove it from the main unit 2 Peel off the glued edge of the pronting paper included with the unit and cut it off to about 2 inches with a pair of scissors and then shape and cut the edge for easv insertion to the printer as shown in the figure Reverse AC J 3 Press the PRINT PAPER FEED button while inserting the edge of the printing paper to the paper feeding slit When the edge of the paper protrudes sufficiently release the button and stop feeding Inserting Direction TASH P i FS A jam Ly 4 Insert the printing paper in the installation section and then attach the cover back to the main unit in such a way that the edge of the paper protrudes from the cover LE nN ol gt La When the PRINT PAPER FEED button is pressed while the results of the measurement are shown on the digital display these results together with the date and time of measurement are printed out When purchasing printing paper ask at the shop where you purchased the main unit for further supply Other brands of paper may be used providing the dimensions are smaller than 38mm wide and 20mm in di ameter However the printing quality may differ a little Preparations f
5. e inner your left upper arm Over the brachi al artery There should be no space between the cuff and your arm NOTE If you have any difficulties wrap ping cuff by yourself we recom mend that you ask someone to wrap the cuff for you 4 about 1 inch Preparations for Use 7 Applv Pressure to the Cuff 1 When vou press the start button the pump operates and pressure is applied When the pressure reaches 170mmbg the pump stops automatically Pias aye gi vax Notes If your systolic blood pressure is higher than 140mmHg the pump starts again and the cuff will be inflated up to 210mmHg If your systolic blood pressure is higher than 180mmHg sufficient inflation will not be applied to the cuff by automatic reinflation In this case inflate up to 30mmHg higher than your expected systolic blood pressure by pressing the start button continuously While press ing the start button the cuff can be in flated continuously and when the start button is released the pump stops and the cuff is no longer inflated When the pressure reaches 300mmHg the cuff deflates rapidly When you want to stop measurememt press SPHYG CLOCK button The pres sure will stop and the air is deflated rapidly 242 Pressure being applied 76 38 g app Depress the START f button continuously untill the cuff is inflated LI up to the targeted pressure After the cuff has Seem ese been inflated release the START butt
6. essed down the figure for the month increases Adjust the month lee E W B 3 When the MODE button is pressed down after the month has been adjusted the day sign is displayed Adjust the day in the same way as the month WUE y Manin ery j 2j 1 G 4 In the same manner select the hour and min with the MODE button and set each value with the SET button AM and PM signs are switched in accordance with the hour ki an FUU ie 5 Press the MODE button for the last time and return the screen to normal time hour min display ETA ent manae omy NN id U U 4 When left side of the main unit correctly the SPHYG CLOCK button is changed to the sphygmomanometer mode all the LCD symbols are momentarily displayed This happens because the unit is running a check on the display and this state lasts for approximately one second ma emy oe nee 8881888 Initial Display Once the LCD symbols vanish the air release indication symbol starts flashing Please wait until the w svmbol goes out WAE met ARTE mm Air release y k indication symbol When the preparations necessary before measurement have been completed the unit emits a series of beeps and finally the Ready to Measure symbol will be displayed 2 f Ready to Measure u Displav Preparations for Use 4 How to
7. he SPHYGICLOCK button The pump will stop and all the cuff pressure will be released rapidly When the PRINT button is pressed while the results of the measurement are shown on the digital display the results will be printed 3 Measurement of the blood pressure is now complete The results will remain displayed even after the cuff is taken off If you wish to carry out repeated measurements repeat the operation from Step 6 The arm gradually becomes congested when measurements are repeatedly taken If you wish to take consecutive measurements take off the cuff and wait at least 3 to 5 minutes between measurements 4 When measurement is completed press the SPHYG CLOCK button to return to the time display If you should forget to press this button the display will return to time display mode automatically after about 5 minutes When Error Indication Symbols Appear The following special error symbols will appear in the display if the unit is being used incorrectly CORRECTION 1 Cuff underinflated 1 Release air pressure in cuff 2 Movement during Wait 10 minutes before taking measurement another reading Repeat Instructions for Use steps except inflate cuff 30 mmHg higher than previous inflation value Residual air pressure Release air pressure in cuff in cuff Wait 10 minutes before taking Cuff overinflated more another reading than 300 mmHg No pulse or blood Repeat Instructions for Use press
8. olic Blood Pressure and Pulse Display Printing Paper Air Jack Paper Cutter MODE Selector Button SPHYG CLOCK Button SET Button START Button PRINT PAPER FEED Button KI Air Plug Air Tube 2 Preparations for Use 1 How to insert the batteries 1 Take off the batterv cover at the back of Replacement the main unit bv sliding it in the direction indicated bythe arrow symbol When the Replace Batteries symbol Battery Cover flashes during measurement please replace the batteries with the new ones When the batteries have run down random numbers may be displayed Points to be careful about whan using the batteries When replacing the batteries please replace all four batteries at once Use the same kind of batteries Take out weak batteries quickly so as to avoid causing damage to the machine Remove the batteries when the unit is not used for extended periods 2 Install 4 AA size batteries attached so that the and polarities on the batteries correctly match the polarities in the battery compartment 3 Replace the cover Preparations for Use 3 Plug in and Turn on 1 Insert the air plug into the air jack on the 2 How to Set Time and Date 1 When batteries are installed the displav shows FM 12 00 sen an pots KIRI 2 When the MODE button is pressed down the month sign is displayed When the SET button is pr
9. on 2 When the appropriate pressure has been reached the air is automatically released and the value on the display window starts to decrease After a while when the artery oscillations are detected the symbol starts flashing and the unit emits a beep ing sound simultaneously The value shown on the display will continue to fall During measurement do not shake the cuff or the air tube pts het TILA 17 Targetted Blood t HU Pressure Reached d Measuring Indicated Value Drops Preparations for Use 8 Blood Pressure and Pulse are displaved 1 When the unit has continued to deflate to a point when the arterv oscillations are no longer detected the unit will displav the svstolic and diastolic blood pressure values along with a long beep and causes the deflation indication symbol w to start flashing After this blood pressure and the pulse readings are displayed alter nately i u oe Measurement 1 al Se t Completed When the deflation symbol begins to flash the residual pressure in the cuff is then rapidly released 2 Upon total cuff deflation a series of beeps are emitted and the symbol is displayed Alternate Display jew A any sen tene aay AT loo ressur H g 5 12 5 Reading Display gt for approx 3 seconds e Pulse Reading p id 5 3 Displav for approx 1 5 sw seconds P Stands for PULSE When you wish to stop measuring during operation press t
10. or Use Though not originally equipped with an ink 3 Insert the supplement ink roller into the roller the HEM 703CP digital blood pressure allotted space next to the printer monitor contains enough printer ink to last about two years when used once a day at normal room temperature Supplement ink roller When the ink on the print out becomes light and hard to read purchase a replacement ink roller from your retailer and install as fol lows 1 Remove the printer cover 4 Replace the printer cover 2 Removethe ink which came with the unit when you bought it from the allotted space NOTE The supplement ink roller should last about two years however if you need to replace the supplement ink roller simply grasp the top of the ink roller and turn itslightlycounterc1 ock wise before lifting the roller from the printer Preparations for Use This cuff has eliminated the need for a 3 Place your arm on a table or a support with microphone thereby lessening possible the palm facing upward so that the cuff is interference from vibrations and noise Fitting placed at the same level as the heart also has been made much easier through the widening of the artery oscillation detection area 1 Place the cuff on the left arm so that the air tube lies across the center of the arm 2 Wrap the cuff pulling in a diagonal angle securely so that the cuff tab is positioned about one inch above the elbow joint of th
11. ordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient the receiving antenna relocate the computer with respect to the receiver move the computer away from the receiver plug the computer into a different outlet so that computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Fedral Communications Commision helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the US Government Printing Office Washington D C 20402 Stock No 004 000 00345 4 LICENSED UNDER U S PAT CUSTOMER SERVICE 4829419 4942516 4896260 4531132 4825364 4686622 4121284 TOLL FREE 1 800 634 4350
12. tion Changes or modifications not expressively approved by OMRON HEALTH CARE INC could void the user s authority to operate this product Note Potential For RadiofTelevision Interference for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interierence will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radiofTV technician for help Potential For RadiofTelevision Interference for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interferencEH
13. ure reading due to steps 1 Motion 2 Very weak artery oscillation Specifications Battery four type AA dry cell batteries 6V 4W Measurement Method Oscillometric Method Display Liquid Crystal Digital Display Measurement Range Pressure 0 280mmHg Pulse 40 200 minute Accuracy Pressure within 3 mmHg Pulse within 5 reading Pressure Detection Capacitive Pressure Sensor Inflation Automatic Pressure Application by a Pump Deflation and Rapid Air Release Automatic pressure release valve Automatic shut off System When the internal pressure in the unit continues at less than 20mmHg for about 5 8 minutes the mode changes automatically to clock Printer Serial static impact printer Operating Temperature Humidity 50 F to 104 F 10 C to 40 C 30 85 RH StorageiTemperature Humidity 4 F to 140 F 20 C to 60 C 10 95 RH Dimensions Approx Main Unit 82 4 w X 51 8 d x 23 5 h 215 x 130x 66 mm Cuff 51 2 w x 184 5 1 140x 480 mm Cuff Range For arms 9 to 13 in circumference Weight Main Unit approx 201 2 oz 580 g including batteries Cuff approx 42 5 oz 125 g Accessories Cuff instruction manual Printing paper 2 rolls Optional parts AC Adaptor Specifications subject to change without notice This equipment generates and used radio frequency energy and if not installed and used properly that is in strict acc