1. C pa appear on the display The Heart Symbol GI flashes at every heart DIASTOLIC mam Fo PULSE min SYSTOLIC mm Hg SYSTOLIC mm Hg 4 The monitor exhausts the residual air when the a x 5 measurement is complete The Heart Symbol 9 stops flashing and your blood pressure an i and pulse rate display alternately Ecce T LSE min PULSE min NOTE Wait 2 3 minutes before taking another blood pressure measurement Waiting allows the engorged blood vessels to return to normal You may require more rest time between readings depending on your individual physiological characteristics Remember To Keep A Record Of Your Blood Pressure And Pulse Measurements MEMORY FEATURE INSTRUCTIONS 1 How to store the measured blood pressure values The measured and displayed blood pressure and pulse rate readings are automatically stored in the memory The memory can store the readings of up to fourteen measurements The memory stores the most recent 14 readings When more than 14 readings have been taken the earliest readings are erased and replaced by the most recent readings The memory is not erased when the batteries are replaced 2 How to recall previously measured readings from memory While the V symbol is displayed you can recall and display readings from the memory starting with the previous measured readings When you push the MEMORY Button M if there is any measured reading stored in the memo
2. card must be completed and sent to us within 10 days from the date of purchase FOR CUSTOMER SERVICE CALL TOLL FREE 1 800 634 4350 14 SPECIFICATIONS Model HEM 629 Display Liquid Crystal Digital Display Measurement Range Pressure 0 to 230mmHg Pulse 40 to 200 minute Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Inflation Automatic by electric pump Deflation Automatic deflation system Rapid Pressure Release Automatic pressure release valve Pressure Detection Capacitive pressure sensor Measurement M ethod Oscillometric method Pulse Wave Detection Capacitive pressure sensor Power Source 2 AAA batteries Battery Life Approximately 1 year when used once a day for two minutes Operating Temperature Humidity 50 F to 104 F 10 C to 40 C 30 to 85 RH maximum Storage Temperature Humidity 14 F to 140 F 10 C to 60 C 10 to 95 RH maximum Console W eight Approximately 5 oz 140g with batteries Outer Dimensions Approximately 3 1 x 3 w x 1 1 2 h 76mm x 76mm x 38mm Cuff Dimensions Approximately 3 x 12 76mm x 304mm W rist Circumference Range Approximately 5 1 4 x 7 3 4 135mm x 195mm A ccessories Carrying case instruction manual 2 AAA batteries These specifications are subject to change without notice
3. period of time HOW TO TAKE A READING Read and follow directions in Suggestions Before Measuring Blood Pressure and How To Apply The Wrist Cuff before taking a reading 1 Press the ON OFF Button a All the display symbols appear for approximately one second This is the initial LCD test b The display symbols disappear and the Deflation Indication Symbol 9 starts to flash c When the monitor completes the necessary preparations before measurement the Heart Symbol appears with a zero 2 Hold the unit at your heart level and press the START button The cuff automatically inflates to approximately 180 mm Hg a Keep the unit at the heart level until the measurement is completed SYSTOLIC mm Hg DIASTOLIC mm Hg PULSE min SYSTOLIC mm Hg DIASTOLIC mm Hg PULSE min SYSTOLIC mm Hg o n al Lt DIASTOLIC mm Hg PULSE min HOW TO TAKE A READING b If during your measurement deflation the monitor determines that a higher pressure value is required it will momentarily stop deflation and automatically increase the pressure value to 230 mmHg C To inflate higher than 230 mm Hg during deflation press and hold the START button until the necessary pressure value is reached DO NOT INFLATE HIGHER THAN 280 mmHg SYSTOLIC mm Hg 3 When the cuff reaches your correct inflation level it begins to deflate automatically RTA As the cuff deflates decreasing numbers A
4. OMRON For Customer Service PO RTA BLE W RIST Call Toll Free BLO O D PRESSURE 1 800 634 4350 MONITOR Model HEM 629 Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 www omron com ohi Copyright 2000 Omron Healthcare Inc Made in China 629INST Rev A TABLE OF CONTENTS Introd ctioni 3 5 iicet eee Ore CIBO RT ven Cie KriowW YOUt D nil s cist iir et er nemen pega Battery Installation Replacement sss ss sene D Suggestions Before Measuring Blood Pressure tee cee tee ee eee 6 How To Apply The Wrist Cuff o oo cece cece see How To Take A Reading sss sse nnne 879 Memory Feature Instruction s se sss ss sense LO TROUDIESHOOUNG sever i ite ee RR PEEL ern MP Care and Maintenance sss ss sss een m men nen nee 13 WSCA eesti esent ertet nre retenta eben D Specifications icc atte beater denote D INTRODUCTION Thank you for purchasing the Omron HEM 629 Portable Wrist Blood Pressure Monitor This remarkable instrument is ideal for people who frequently monitor their own blood pressure because it s so compact and easy to use There is no tricky arm cuff just a small pre formed wrist cuff that is easy to apply With the push of a button the Omron Wrist Monitor measures your blood pressure and pulse rate and displays the reading on a clear digital panel Perfect for quick easy readings at home at work and during travel The Omron Wrist Mo
5. Omron HEM 629 Portable Wrist Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of five years under normal use The five year warranty excludes the monitor cuff The cuff is warranted for a one year period This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit prepaid to Omron Healthcare Inc Attn Repair Dept 300 Lakeview Parkway Vernon Hills IL 60061 include 5 00 for the return shipping and insurance Be sure to include the model number of your unit and your phone number on any correspondence We will either repair or replace at our option free of charge any parts necessary to correct defects in the materials or workmanship The above warranty is complete and exclusive The warrantor expressly disclaims liability for incidental special or consequential damages of any nature Some states do not allow the exclusion or limitation of incidental or consequential damages so the above warranty may not apply to you Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state As a condition to operation of your warranty the enclosed registration
6. for purposes of improvement The attached batteries are only to confirm the unit operation They may run out before indicated battery life 15
7. ing Digital Display Diastolic Blood Pressure Pulse Rate MEMORY button M 2 Mental stress raises blood pressure 3 Throughout the measurement the unit should be held at your heart level The carring case is large enough to raise the arm to heart level W rist Cuff ON OFF Button 4 Remain still and do not talk during the measurement STA RT Button Battery Cover BATTERY INSTALLATION REPLACEMENT HOW TO APPLY THE WRIST CUFF 1 Slide the battery cover off in the direction of the arrow 1 Hold your left arm in front of you with your palm facing up Apply the cuff so that the monitor is on the inside of your wrist with the display in easy view 2 Insert or replace 2 AAA size batteries so that the positive and negative markings 2 The cuff s edge should be match those in the battery approximately 1 4 to 1 2 inch compartment from below your palm 1 4 3 Replace the battery cover 3 Wrap the cuff snugly around your wrist The top and bottom edges of the cuff should be tightened evenly around your wrist 4 If the Low Battery Indicator appears on the display replace both batteries Long life alkaline batteries are recommended 4 When the cuff is positioned correctly secure it in place by pressing the pile material firmly against the hook material 5 Remove the batteries if the Low Battery Indicator monitor will not be used for an extended
8. nitor uses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through the artery in your wrist and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use and measurements are easy to obtain Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm Changes in wrist bloodpressure reflect changes in arm blood pressure because the arteries in the wrist and the arm are close to each other Frequently measuring the blood pressure in your wrist will provide you and your doctor with an accurate indication of changes in your blood pressure Consult your physcician before measuring blood pressure at the wrist if you have any of the following conditions severe hypertension severe diabetes severe arterialsclerosis severe kidney disease or vasculor disease that may compromise circulation Please read this instruction manual thoroughly before using the Omron Portable Wrist Blood Pressure Monitor For specific information on your own blood pressure CONTACT YOUR PHYSICIAN 3 SUGGESTIONS BEFORE KNOW YOUR UNIT MEASURING BLOOD PRESSURE 1 Eating smoking and exercising within 30 minutes before taking a measurement may affect your blood Systolic Blood Pressure pressure To take baseline blood pressure rest for at least 5 minutes before taking a read
9. ocks installation If the product does cause harmful interference to radio or television for example dropping the monitor on the floor reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures icut vE Cleaning the monitor with volatile liquids THE MONITOR Reorient or relocate the receiving antenna ncrease the separation between the product and receiver SHOULD BE CLEANED WITH A SOFT DRY CLOTH Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le materiel brouilleur Appareils Numeriques NMB 003 edictee par le ministre des communications LICENSED UNDER U S PAT 4829419 4942516 4896260 4531182 4825364 4686622 4121284 4396976 4371923 4471385 4120583 4435732 4672457 4739396 12 13 LIMITED FIVE YEAR WARRANTY Your
10. re the pressure indication e reaches 280 mmHg or higher LI Battery voltage is Replace both AAA batteries excessively low See page 5 pA NOTES Wait 2 3 minutes before taking another measurement If you continue to have difficulty obtaining a reading call OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1 800 634 4350 Please tell the representative you have an Omron HEM 629 Portable Wrist Blood Pressure Monitor 11 CAUTION CARE AND MAINTENANCE CAUTION To protect your monitor from damage and loss Changes or modifications not expressly approved by O mron of warranty please AVOID the following Healthcare Inc will void the user s warranty Subjecting your monitor to extreme temperatures humidity and direct sunlight NOTE POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only Washing or moistening the cuff This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference Disassembling the monitor in a residential installation The product generates uses and can radiate d radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications anG However there is no guarantee that interference will not occur in a particular s Subj ecting the monitor to strong sh
11. ry M1 indicating the latest memory the systolic and the diastolic blood pressures and the pulse rate are displayed alternatively In order to recall the readings measured previously push the MEMORY Button M again The values will be displayed as M2 M3 etc If there is no measured reading in the memory a blank screen with dashed lines will be displayed when the MEMORY Button M is pushed 3 How to erase the memory All the measured readings stored in the memory can be erased simultaneously by operating the buttons as follows While the Y symbol is displayed push the MEMORY M and the START Buttons simultaneously Hold both buttons down for at least two seconds a blank screen with dashed lines will be displayed and the measured readings stored in the memory will be erased 10 TROUBLESHOOTING Error Indicator Cause Correction Cuff under inflated Retake measurement by setting 55 cuff inflation level 40 mmHg LL higher than previous level by Pr keep pressing the START me BUTTON until the cuff pressure reaches the necessary level Movement during Be sure not to move and talk pag measurement during the measurement Eum E Wrap the cuff snugly around LL Ao pule or pate DE your wrist carefully read and alse 8 Ty repeat steps listed under How puse To Apply The Wrist Cuff page 6 pag Cuff over inflated more Release the START BUTTON u than 300 mmHg befo