Home

Omega OS541 User's Manual

image

Contents

1. 5 Emissivity Maintenance Replace Battery 6 Infrared Recorder I N SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter Only qualified personnel should perform repairs or servicing not covered in this manual Periodically wipe the case with a dry cloth Do not use abrasives or solvents on this instrument Safety symbols A Dangerous refer to this manual before using the meter C Apply with European CE This instrument conforms to the following standards EN50081 1 1992 Electromagnetic Emissions EN50082 1 1997 Electromagnetic Susceptibility Test were conducted using a frequency range of 80 1000 MHz with the instrument in three orientations The average error for the three orientations is 2 0 4 0 at 3V m throughout the spectrum However between 300 MHz and 500 MHz at 3V m the instrument may not meet its stated accuracy Warning of laser Do not point laser directly at human eye or indirectly from reflective surfaces CAUTIONS Before using the infrared thermometer you notice the following Infrared Recorder Away from electrical welders induction heaters and EMF sources When using this thermometer under large or abrupt ambient temperature changes allow 15 minutes for unit to stabilize before use Do not keep thi
2. RANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat mois ture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components which wear are not warrant ed including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various prod ucts However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufac tured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEV ER EXPRESS OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMI TATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligenc
3. 6342 e mail info omegashop cz 11 rue Jacques Cartier 78280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom Tel 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales omega co uk It is the policy of OMEGA to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications CONTENT Page I SAFETY INFORMATION 2 Il CAUTIONS 2 GENERAL SPECIFICATION 3 IV NAME AND FUNCTION 4 V OPERATION INSTRUCTIONS Measuring Trigger 5 Distance to Spot Ratio D S
4. A YEAR C WARRANTY Shop online at CEOMEGA www omega com e mail info omega com 1509001 1509002 cenil mum STAMFORD CT MANCHESTER UK CAUTION OS541 Infrared Thermometer omega com LEOMEGA OMEGAnet On Line Service Internet e mail www omega com info omega com USA ISO 9001 Certified Canada Servicing North America One Omega Drive Box 4047 Stamford CT 06907 0047 Tel 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada Tel 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance USA and Canada Mexico Benelux Czech Republic France Germany Austria United Kingdom ISO 9002 Certified Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info omega com mx Servicing Europe Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 0 20 3472121 FAX 31 0 20 6434643 Toll Free in Benelux 0800 0993344 e mail sales omegaeng nl Frystatska 184 733 01 Karvin Czech Republic Tel 420 0 59 6311899 FAX 420 0 59 6311114 Toll Free 0800 1 6
5. CTIONS Measuring Trigger To measure a temperature point the unit at an object and pull the trigger Be sure to consider distance to spot size ratio and field of view The laser is used for aiming the target for reference When the laser is on you can switch between laser dot and circle by moving a lever in front of optics Laser dot is an indication of the center of the field of view Laser circle is an indication of the perimeter of the field of view The temperature reading will be updated on the LCD When the operator releases the trigger the reading will automatically be held on the LCD for 10 more seconds After 10 seconds this thermometer will power down itself to save battery Distance to Spot Ratio D S You have to make sure that the detection area you want to measure is larger than the required spot size to get a correct reading The temperature you get is an average temperature of the detected region The smaller the target the shorter distance is required for the measuring Please refer to the diagram on the side of the unit Distance Spot 8 1 Spot Size 800 Measuring Distance Unit mm Infrared Recorder Emissivity Emissivity is a term used to describe the energy emitting characteristics of materials The higher of this value means the more capability of radiation emittance the materials has Most organic materials and painted or oxidized surfaces have an emissivity of 0 98 Metal surf
6. aces or shiny materials has a lower emissivity and give inaccurate readings Please note this during applications Maintenance Blow off loose particles using a lens blow Gently brush remaining debris away with a lens brush Carefully wipe the surface with a moist cotton swab The swab may be moistened with water NOTE Don t use solvents to clean the glass lens Replace Battery When the battery voltage drops below that required for reliable operation the low battery symbol will appear indicating it is the time to replace the battery To change the 9V battery detach the battery compartment cover by pushing the engraved pattern on the handle and pull down Change the 9V battery with new one and put the battery cover back WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number imme diately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WAR
7. e indemnification strict liability or otherwise shall not exceed the purchase price of the compo nent upon which liabi is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please FOR NON WARRANTY REPAIRS have the following i
8. ers amp Strain Gages 04 Load Cells amp Pressure Gages 4 Displacement Transducers 64 Instrumentation amp Accessories FLOW LEVEL EF Rotameters Gas Mass Flowmeters amp Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems 04 Totalizers amp Batch Controllers pH CONDUCTIVITY 04 pH Electrodes Testers amp Accessories Zg Benchtop Laboratory Meters EF Controllers Calibrators Simulators amp Pumps W Industrial pH amp Conductivity Equipment DATA ACQUISITION W Data Acquisition amp Engineering Software 64 Communications Based Acquisition Systems 4 Plug in Cards for Apple amp Compatibles LF Datalogging Systems 0 Recorders Printers amp Plotters HEATERS 04 Heating Cable 04 Cartridge amp Strip Heaters 64 Immersion amp Band Heaters 0 Flexible Heaters 4 Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL 04 Metering amp Control Instrumentation 04 Refractometers 6 Pumps amp Tubing W Air amp Water Monitors A Industrial Water amp Wastewater Treatment pH Conductivity amp Dissolved Oxygen Instruments M3920 1203
9. nformation consult OMEGA for current repair available BEFORE contacting charges Have the following OMEGA information available BEFORE 1 Purchase Order number under contacting OMEGA which the product was 1 Purchase Order number to cover the PURCHASED COST of the repair 2 Model and serial number of the 2 Model and serial number of the product under warranty and product and 3 Repair instructions and or specific 3 Repair instructions and or specific problems relative to the product problems relative to the product OMEGA s policy is to make running changes not model changes whenever improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2003 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do Find Everything I Need for Process Measurement and Control OMEGA Of Course Shop online at www omega com TEMPERATURE Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies 04 Wire Thermocouple RTD amp Thermistor Calibrators amp Ice Point References 04 Recorders Controllers amp Process Monitors 64 Infrared Pyrometers PRESSURE STRAIN AND FORCE 04 Transduc
10. s thermometer in the environment of high temperature for a long time e Keep away from dusty environment and keep in carry case after operation to avoid contamination of optical lenses lll GENERAL SPECIFICATION Display 4 digit LCD Display Illumination Backlight by LED Field of View 8 1 Target Indicator Laser spot Emissivity 0 98 Power Off Automatic power off after 10 seconds Temperature Range 20 500 C 4 932 F Accuracy 2 C 4 F or 2 of reading Resolution 0 5 C 0 5 F Repeatability Within 1 of reading or 1 C 2 F Storage Condition 10 60 C 14 140 F lt 75 RH Operating Condition 0 40 C 32 104 F 10 90 RH Response time 0 5 second Battery 9V battery 006P IEC6F22 NEDA1604 Battery Life Approximately 15 hrs Alkaline Dimension 157 5x115x36mm 17 5x4 5x1 4inch Weight 180g Approx Accessory 9V battery instruction manual carrying case Infrared Recorder IV NAME AND FUNCTION eO T Laser dot circle switch Infrared sensor aperture Laser on off switch C F switch Measuring Trigger Battery cover LCD display LCD Display Scan indication Laser on indication r A SCAN L Data Hold indication Low battery 1 HOLD c L Temperature unit nuncu Digital value 71 F indication indication 8 Li 4 Infrared Recorder V OPERATION INSTRU