Olympus MAJ-222 User's Manual
Contents
1. To insert this chart into a binder punch out the holes and fold the chart as illustrated C To use this chart as a wallchart cut i off the top of the chart as illustrated a C EXERA BF 160 Series and EVIS BF 240 Series Bronchovideoscopes Refer to the companion BRONCHOSCOPE CLEANING GUIDE tor detailed cleaning information RA WARNING This guide is only a summary of the steps necessary to properly disinfect your bronchoscope Be sure to follow the detailed steps outlined in the ENDOSCOPE REPROCESSING MANUAL that was included with your bronchoscope when purchased Suction Cleaning Adapter Fill basin with disinfectant Attach a suction cleaning adapter MAJ 222 to the previously cleaned broncho scope Immerse completely in disinfectant solution Attach a syringe to the adapter Pull the plunger of the syringe to fill the instrument suction channels and channel cleaning adapter with disinfectant solution Connect the suction cleaning adapter and syringe Inject air to remove disinfectant from the instrument suction channels then remove the bronchoscope Disconnect the suction cleaning adapter and immerse the bronchoscope and adapter in sterile water Using a sterile lint free cloth thoroughly rinse While immersed detach the adapter from
2. ing vertically with all valves and caps removed e Use a compatible disinfectant and test it for proper concentration as recom mended by the manufacturer Single Use Biopsy Valve MAJ 210 Instrument Suction Channel Port i e Do not use the carrying case to store patient ready endoscopes Any broncho a scope placed in the carrying case must be Water Resistant Cap reprocessed prior to patient use Insertion Tube MH 553 Benang seciiai Clean the bronchoscope meticulously prior to disinfection Control Section UP DOWN Angulation Control Lever Distal Tip 2004 Olympus America Inc Printed in USA 01 04 PWC 100016 OLYMPUS Your Vision Our Future
3. the bronchoscope Use a clean lint free cloth to wipe away any bub bles clinging to external surfaces To Suction a I N Connect suction cleaning adapter to bronchoscope and to a tube from a suction pump Aspirate water through channels for 30 seconds Remove from water and Soak all equipment according to the time and temperature recommended by the disinfectant manufacturer Use a timer to measure the exact contact time Suction Cleaning Adapter MAJ 222 Pi To Suction Pump Alcohol Immerse the bronchoscope s distal end in 70 alcohol and aspirate alcohol for 5 seconds Remove the distal end from the alcohol and aspirate air for 20 seconds from the disinfectant aspirate air through channels for 60 seconds and wipe all surfaces 9 Dry the bronchoscope and adapter with an alcohol moistened cloth Make sure that the equipment is completely dry prior to storage Turn the suction pump off Hold the control section with the openings pointing down and i i i Hold all parts of the endoscope when carrying Do disconnect the suction cleaning adapter not let the ends of the bronchoscope swing freely e Wear appropriate personal protective l l equipment during reprocessing Single Use Suction Valve MAJ 209 Universal Cord Light Guide e Autoclave all autoclavable accessories Suction Cylinder e Store the bronchoscope hang
Download Pdf Manuals
Related Search
Related Contents
MD-500EM - Optimus PSC [file] - Sardegna Ricerche Samsung LA37S8 User's Manual Skewer - The UK Mirror Service Axis Q6032 PTZ Tripp Lite 3ft. USB 2.0 A - DC elevador hidráulico trolley jack cod. 51101 Copyright © All rights reserved.
Failed to retrieve file