Home
Nuvo NV-E6DMS-DC User's Manual
Contents
1. SOURCE LINK Source 1 Tuner 1 Fig 6 dise n NUVO VII Expanding Essentia to 12 Zones Six additional listening zones can be added to the Essentia System using the Essentia Expander package The expansion is easily done using the Source Link and Digital Link multi pin outputs on the Essentia main amplifier Fig 7 The necessary cables for this are supplied with the Expander package No other connections are necessary with the exception of the AC power cord and the additional speaker terminations The additional CAT5 wires for the zones 7 12 plug into the EZ Port VIII Installing the Essentia Keypads You are now ready to install the keypads and complete the Essentia installation This is easily done using a rotary switch located on the back of the keypad to set a specific zone address for each keypad Fig 8 The switch requires the use of a small flat screwdriver and is set by turning the arrow insert on the switch to the appropriate zone number Zones 1 12 are set by using switch positions 1 C note that zones 10 11 and 12 are denoted by A B and C respectively Switch positions D E F and 0 are for additional keypads in zones 1 4 It is important to note that the keypads will not function properly unless each has its own unique zone address Once each keypad s zone address is set the CAT5 can be plugged in and the keypad installed in the wal
2. One or more of the IR emitters are not properly placed over the IR receiver on the audio source equipment or the IR output on the Essentia does not correspond with the audio equipment you are controlling 20 Remedy Check that you are using the 568A or B wiring standard see section Crimping CATS wire The best way to know is to use a CATS tester Each keypad must have a unique address set with the Zone Address rotary switch located on the back of the keypad see section VII Installing the Essentia keypads The fuse is accessed at the back of the amplifier where the AC cord plugs in It requires a 4 amp time delay fuse Pressing and holding the active Source button on the keypad will activate a lock feature and prevent any functionality When locked the keypad will simply flash when a function is attempted Pressing and holding the source button again will unlock the keypad Pressing the MUTE and Source 3 button simultaneously sets the Source Grouping feature This will cause multiple keypads to always share the same source see Section IX Zone EQ and Source Grouping on page 11 Make sure the amplifier is turned on Test that the POWER LED on the amplifier turns on when the Network Cable is unplugged Next unplug all the CATS cables from the EZ Port and plug them back in one at a time until the bad cable s is discovered Reposition the LED end of the emitter on the face of the source equipment so it
3. USE NV SLC1 RS 232 NNECTTON CONNECT TO NV E6DX USE NV SLC1 CABLE 2 DWO 6 WADD Wd G Essentia Back Panel 1 Audio Source Inputs The Essentia amplifier accepts up to six audio sources source consists of any audio component capable 2 Source Link 3 Variable Lineout 4 Fixed Lineout 5 Speaker Outputs 6 Zone Triggers 7 Emitter Outputs 8 System On 9 External Mute 10 Network Input 11 Digital Link 12 RS232 Port 13 AC Power of supplying a line level signal This multi pin connection is used to transfer the audio information from the Essentia main amplifier to the expander amplifier This output is used to expand the system to twelve zones The source link connection cable is provided with the Essentia D Expander package The variable lineout is intended for zones where additional amplification is needed and the Essentia keypad is used to control the volume of all the speakers in that zone The fixed lineout is intended for zones where additional amplification and separate volume control are needed Individual stereo speaker outputs for each zone provide 20 watts output per channel These outputs provide a 12 volt output when the corresponding zone is turned on This is used to trigger external equipment specific to a given zone These outputs transfer IR infrared signals repeated from a zone keypad from the Essentia amplifier to the audio sourc
4. Blue Stripe Orange Brown Stripe Brown Note Colors listed as stripe are a white wire with a colored stripe Step 3 NUVO Il Installing the Essentia Amplifier System setup works best when the amplifier is placed in the same location as the audio source equipment This is typically in an audio rack entertainment center or a closet dedicated to housing the home audio video equipment The amplifier should be plugged in and the power button on the front panel should be depressed before proceeding with the rest of the installation This activates the internal protective circuitry of the Essentia System Il Terminating Speaker Wire The speaker wire for each zone is terminated in a standard Euro style connector that plugs into each zone specific amplified output The common speaker termination scheme is Left Left Right Right Either two or four conductor 16 guage wire is recommended Larger than 14 guage wire will not fit into the euro connector To terminate the speaker wire strip back the outer jacket and expose the inner conductors Strip approximately 1 4 4 mm of the insulation from the inner conductors exposing the copper wire Place the exposed wire in the euro connector and tighten the screw down terminals fig 2 Be careful not to allow the exposed wire from each conductor to touch the adjacent conductor This will short the speaker input Each speaker output is designed for two 8 Ohm
5. is flashing directly over that source s IR receiver Make sure that the emitter plugged into IR Output 1 is actually going to source 1 and so on for sources 2 6 NUVO Specifications Zones 1 6 Power Amplifier Outputs Continuous Average Output Power Two channels driven 30 20kHz 1 THD 40W 20W x 2 Rated Distortion 1 2 power 0 40 Rated Impedance 6 Ohms Damping Factor 50 Frequency Response 20 20kHz 2 dB Zones 1 6 Preamplifier Outputs Variable output 0 600mV Fixed output 600mV Impedance 600 Ohms Source Inputs 1 6 input Impedance 10K Input Sensitivity for rated power 300mV RMS Input Overload 3V RMS Emitter Outputs Source Outputs 6 Sum Outputs 2 Output Drive Current 100mA Output Drive Voltage 12V Compatible with single and dual emitters System System On 12V 50mA External Mute 3 12V DC 21 Zone Trigger Outputs Output Power Outputs Power Requirements Power Supply Power Consumption all channels driven to full rated power Cower Consumption average operating conditions Power Consumption no signal USA Safety Listing UL 6500 Canada Safety Listing CAN CSA E60065 00 CE Listing SEMKO EN60065 EN55013 EN55020 EN6100 3 2 EN6100 3 3 A1 Physical Specifications Unit Size Millimeters Unit Size Inches Shipping Size Millimeters Shipping Size Inches Unit Weight Kilograms Unit Weight Pounds Shipping Weight Kilograms Shipping Weight Pounds Keypad Size Millimeters Keypad Size Inches N
6. AVERTIR L UTILISATEUR DE LA PRESENCE DE VOLTAGE DANGEREUX NON ISOLE A L INTERIEUR DE CE PRODUIT QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES D INSTRUCTIONS D UTILISATION ET DE MAINTENANCE DANS LES l CE SYMBOLE A POUR BUT D AVERTIR L UTILISATEUR DE LA PRESENCE DOCUMENTS FOURNIS AVEC CE PRODUIT ELECTRIQUE NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A 1 AFIN DE REDUIRE LES RISQU D INCENDIE ET DE DECHARGE L HUMIDITE 10 11 12 13 14 15 16 IMPORTANTES INSTRUCTIONS DE SECURITE Lire avec attention toutes les recommandations et pr cautions d emploi avant d utiliser ce produit Toutes les recommandations et pr cautions d emploi doivent tre conserv es afin de pouvoir s y reporter si n cessaire Lire et comprendre tous les avertissements num r s dans les pr cautions d emploi Suivre toutes les pr cautions d emploi pour utiliser ce produit Ce produit ne doit pas tre utilis pr s d eau comme par exemple baignoires viers piscine sous sol humides Etc Utiliser exclusivement un chiffon sec pour nettoyer ce produit Ne bloqu r aucune ouverture de ventilation Ne pas placer le produit tout contre un mur ou dans une enceinte fern e cela g nerait le flux d air n cessaire au refroidissement Ne pas placer le produit pr s de toute source de chaeur telle que radiateurs arriv es d air chaud fourneaux ou autres appareils g n rant de
7. Danger L exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l audition Chaque organisme humain reagit differemment quant a la perte de l audition mais quasiment tout le monde subit une diminution de l acuite auditive lors d une exposition suffisamment longue au bruit intense Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits DURE EN HEURES PAR JOUR 864321 INIVEAU SONORE CONTINU EN dB 90 93 95 97 100 103 Selon les autorites toute exposition dans les limites citees ci dessus peuvent provoquer certaines pertes d audition Des bouchons ou protections dans l appareil auditif ou sur l oreille doivent etre portes lors de l utilisation de ce systeme d amplification afin de prevenir le risque de perte permanente de l audition Dans le cas d expositions superieures aux limites precitees il est recommande afin de se premunir contre les expositions aux pressions acoustiquese evees potentiellement dangeure u ses aux personnes exposees aux equipements capables de delivrer de telles puissances tels ce systeme d amplification en fonctionnement de proteger l appareil auditif ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR ATTENTION AFIN DE LIMITER LE RISQUE DE CHO ELECTR QUE NE PAS ENLEVER LE CHASSIS NE CONTIENT PAS DE PIECES POUVANT ETRE REPAREE PAR L UTILISATEUR CONFER LE SERVICE APRES VENTE AUX REPARATEURS CE SYMBOLE A POUR BUT D
8. specific volume control such as a TV or stereo receiver This is not used for NuVo zone volume 6 Numeric Buttons These buttons provide source specific 2 direct numeric access 7 Power Button This power button is for source specific power on and off Itis not for NuVo zone 0 on and off 8 Channel up and down This button provides source specific channel scrolling AO TA 0 Gz NV LRC1 9 Macro Buttons These buttons do not perform a given source function They can be used for programming multiple function macro commands NUVO Installing the Essentia System in Your Home Prewire The Essentia System uses CATS cable for keypad control and either two or four conductor 16 gauge speaker wire All the wire is homerun from each zone to the location of the Essentia amplifier and Audio Source equipment Complete CATS Crimping Instructions The NuVo audio systems require CAT5 unshielded twisted pair UTP for communication between the keypads Display Pads and the main amplifier unit Each end of the wire is terminated with an RJ45 connector The Essentia System can accommodate 2 000 total feet of CATS cable For the most reliable operation it is best that no single run of CATS exceeds 250 feet The correct wiring scheme for the CATS cable is standard EIA TIA 568A Properly terminating the CATS cable is crucial for the oper
9. using 568A or 568B network wiring will suffice should you need a longer connection V Attaching Audio Source Equipment to the Essentia Amplifier Each piece of audio source equipment is connected to the Essentia amplifier with standard stereo RCA cables Attach the RCA cable to the corresponding audio output on the source equipment and to the desired source input on the back of the Essentia amplifier Fig 5 VI Connecting the IR Emitters IR commands for the source equipment are transferred from the Essentia amplifier to the source equipment via mini IR mouse emitters Six of these are supplied with your Essentia System The emitter is plugged into the corresponding source IR output on the Essentia and then placed over the IR receiver window on the source component fig 6 The IR outputs are individually routed to sources 1 6 allowing IR commands from the chosen source to only control that source The two SUM outputs will flash any IR command that is sent from any of the zones This is used to connect the NuVo T2 Tuner which has a single IR direct input to control both tuners to the Essentia System or an IR blaster designed to flash IR commands to a variety of components This is done by plugging a single mono 1 8 patch cable into the SUM IR output and into the Direct IR input Fig ee EZ Port front Essentia Network Connection Network Cable Fig 5 CONNECT TO NV E6DX USE NV SLC1 CABLE
10. E NE PAS OUVRIR THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF NON INSULATED DANGEROUS VOLTAGE WITHIN THE PRODUCT S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE ARISK OF ELECTRIC SHOCK TO PERSONS THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE SERVICING INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT gt APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUIDS SUCH AS VASES SHALL BE PLACED ON THE APPARATUS 10 11 12 13 14 15 16 IMPORTANT SAFETY INSTRUCTIONS Read all safety and operating instructions before using this product All safety and operating instructions should be kept for future reference Read and understand all warnings listed on the operating instructions Follow all operating instructions to operate this product This product should not be used near water i e bathtub sink swimming pool wet basement etc Only use dry cloth to clean this product Do not block any ventilation openings It should not be placed flat against a wall or placed in a built in enclosure that will impede the flow of cooling air Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A po
11. NUVO The Sound of LiVing Essentia Six Source Six Zone Audio Distribution System NV E6DMS DC NV E6DXS DC Installation Manual NUVO ENGLISH Danger Exposure to extremely high noise levels may cause a permanent hearing loss Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time The U S Government s Occupational Safety and Health Administration OSHA has specified the following permissible noise level exposures DURATION PER DAY HOURS 8 6 4 3 2 1 SOUND LEVEL dB 90 93 95 97 100 103 According to OSHA any exposure in the above permissible limits could result in some hearing loss Ear plugs or protectors in the ear canal or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss If exposure in excess of the limits as put forth above to insure against potentially harmful exposure to high sound pressure levels itis recommended that all persons exposed to equipment capable of inducing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation hy CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE CHASSIS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL AVIS RISQUE DE CHOC ELECTRIQU
12. VO_E6D_vx yy lt CR gt where x is the major version number and yy is the minor version number kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk RESPONSE EXTMON lt CR gt Issued whenever the External MUTE first activates closure to ground and 0 whenever the External MUTE de activates open connection to ground NOTE there is no COMMAND associated with this response it is always initiated by a change at the EXT MUTE input kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk RESPONSE EXTMOFF lt CR gt Issued whenever External MUTE de activates open connection to ground NOTE there is no COMMAND associated with this response it is always initiated by a change at the EXT MUTE input 27 NUVO The Sound of LiVing www nuvotechnologies com 2395 Arbor Tech Drive Hebron KY 41048 Phone 859 817 7200 Toll Free 866 796 4904 ESS513 0706
13. and off by any zone keypad When connected to the keypad the user will listen to the NuVo audio system when the zone is turned on When the zone is off the LSA40 will automatically amplify any incoming local audio signal Fig 18 NuVo System zone speakers a Er VII Oo dl Je A two conductor wire is used as a voltage trigger from the LSA40 the NuVo zone keypad When the zone is turned on this allows to NuVo system audio to pass to the zone speakers When the zone is turned off the internal amplifier of the LSA4o is automatically engaged Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier Zone Room 1 The connection from the LSA4o to the Essentia or Concerto keypads is done using the provide two prong plug SA40P Front LSA4oP Back 50 Watt AC power adapter supplied with the LSA40P 16 NUVO XIV NV LSA40PD Local Source Amplifier Power Distribution Hub The LSA40PD is a great device for distributing the necessary DC power to up to 4 individual LSA40 amplifiers This allows the LSA40 components to be remotely located without the need for an external power supply in the zone fig 19 The LSA40PD is typically located where the Essentia amplifier is installed The power from the head end to each of LSA40 locations i
14. ation of the system It is very important to use a good quality crimp tool and test each end to end run with a CATS wire tester to insure that your system operates flawlessly fig 1 Step by Step Crimping Instructions l Strip a 2 to 3 inch portion of the insulation exposing the 4 twisted pairs 2 Untwist the wires and fan them out individually Arrange the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimmer built in It is best to trim the wires to about 2 in length 4 While holding the wires flat between your thumb and forefinger insert the wires into the RJ45 connector so each is in its own slot Push the wire into the RJ45 so all 8 conductors touch the end of the connector The insulation jacket should extend beyond the crimp point of the RJ45 5 Insert the RJ45 into the crimp tool receptacle and squeeze the tool firmly Note that a ratchet type tool should tighten down until it no longer clicks 6 The RJ45 should be firmly crimped to the CATS insulation It is necessary that the color scheme be repeated identically on each end of the wire Top view with tab down 12345678 O J L aira Pair4 yiz ir 3 Wires insert from this end Fig 1 EIA 568A wiring scheme for CAT5 Cable Pin 1 Green Stripe 2 Green PN Dp Y Orange Stripe Blue
15. e aa IR carrier frequency of SOURCE 1 38 or 56 bb carrier frequency of SOURCE 2 38 or 56 cc carrier frequency of SOURCE 3 38 or 56 dd carrier frequency of SOURCE 4 38 or 56 ee carrier frequency of SOURCE 5 38 or 56 ff carrier frequency of SOURCE 6 38 or 56 22 NUVO NOTE the Main Unit ships with the carrier frequency DEFAULT setting of 38 KHz for all six sources kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND IRSETDF lt CR gt Restores DEFAULT SOURCE IR carrier frequency settings 38 KHz for all six sources RESPONSE Same response as for IRSETSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND SxIR56SET lt CR gt sets SOURCE x to 56 KHZ IR repeat carrier x is 1 to 6 RESPONSE Same response as for IRSETSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND SxIR38SET lt CR gt sets SOURCE x to 38 KHz IR repeat carrier x is 1 to 6 RESPONSE Same response as for IRSETSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND RESPONSE DESCRIPTIONS NOTE zone number field xx should ALWAYS include a lead zero 0 for zone numbers less than 10 COMMAND ZxxCONSR lt CR gt Connect STATUS REQUEST where xx is zone from 1 to 12 RESPONSE ZxxPWRppp SRCs GRPt VOL yy P
16. e additional speakers being driven by an additional amplifier This is common with outdoor zones The fixed lineout offers the capability to add amplification but the audio signal is not affected by the zone keypad volume level Therefore it requires a separate volume control for those speakers fig 16 Fig 16 BE Sea Zone Room 1 Additional speakers are controlled by a separate volume control Diagram shown using the NuVo P2100 amplifier rower Essentia D eran V I CONNECT TO NV E6DX Source 1 Tuner 1 Ox 14 NUVO XI The NV LRC1 IR Remote Control The Essentia System comes with the NV LRC1 Learning Remote Control This remote allows wireless control of all keypad functions as well as the functions of the audio source equipment Each NuVo zone keypad has an IR receiver that captures the specific source commands from any remote control and in turn sends the command ultimately to the appropriate source equipment Embedded IR code libraries makes use of the LRC1 with a large variety of audio and video equipment easy For complete setup and functionality refer to the User Guide included with the remote control Additional remote controls are available from NuVo XII NV MI1 Mute Interface Adapter The Mute Interface is used in conjunction with System Mute input in the back of the Essentia amplifier It acts as a relay for a v
17. e equipment There are six source specific outputs and two sum output that sends IR signals regardless of the selected source This output provides a constant 12 volt output when any zone is turned on This is used to trigger external devices This is designed to mute any audio playing through the system when the phone or doorbell rings This RJ 45 connection is the input for all zone information coming from the Essentia keypads The connection is made using the Network Cable supplied with the package This multi pin connection transfers all the digital information from the main amplifier to the expander amplifier This output is used to expand the system from six to twelve zones The Digital Link connection cable is provided with the Essentia D Expander package The RS232 serial port allows two way communication for control by a home automation system A detachable power cable supplies power to the Essentia System from any AC outlet NUVO LRC1 Learning Remote Control 1 Setup The setup button is used to place the remote control in program learn mode 2 Whole Home Control This section automatically performs the basic Essentia keypad functions 3 Transport Buttons The transport buttons perform basic source specific functions such as play stop pause forward and reverse O 4 Video Source Control These buttons are typically used by video equipment for menu navigation and selection 5 Source Volume This is source
18. e the zone Vv will automatically turn on at a preset 60 dB level The volume reset can be turned off by repeating the above steps and returning the volume LED to the far left position 12 NUVO X Using the Fixed and Variable Lineouts Each zone of the Essentia amplifier has two 3 5mm mini stereo outputs These are fixed and variable lineouts used for adding additional amplification when necessary for each zone A distinct advantage to the NuVo equipment is the ability to use the amplified output variable and fixed lineouts all simultaneously on all zones The Essentia amplifier has zone trigger outputs that provide a 12V trigger for additional amplification This enables the attached amplifier to be triggered on and off with the zone keypad Zone Variable Lineout The variable lineout is designed to allow additional audio amplification volume level to be controlled from that zone s keypad When used in conjunction with the zone amplified output fig 15 all the speaker s volume will track with the keypad volume level Fig 15 BE DEAE Zone Room 1 The Zone keypad controls the audio volume Diagram shown using the NuVo P2100 amplifier CONNECT TO NV E6DX USE NV SLC1 Source 1 5 Tuner 1 O 13 NUVO Zone Fixed Lineout In some zone applications itis more advantageous to have a separate volume control on th
19. inimum volume one reference zone must be periodically polled with a ZxxCONSR lt CR gt Command to determine when the desired volume point has been reached Note that ramps in different zones may start at different levels and will all ramp at the same rate kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLHLD lt CR gt Stops ramp action initiated by ALLV lt CR gt Or ALLV lt CR gt RESPONSE ALLHLD lt CR gt This results in a HOLD of the level at time of command receipt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLMON lt CR gt ALL MUTE ON RESPONSE ALLMON lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLMOFF lt CR gt ALL MUTE OFF RESPONSE ALLMOFF lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxSRCp lt CR gt Switch zone xx to SOURCE p 1 to 6 RESPONSE Same response as for ZxxCONSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxVOLyy lt CR gt Set volume of zone xx to level yy below max in dB from 0 to 78 dB include lead 0 for all single digit values RESPONSE Same response as for ZxxCONSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxVOL lt CR gt STARTS zone xx volume ramp UP at the ra
20. kkkkkkkkkkk COMMAND ZxxVRSTON lt CR gt zone xx VOLUME RESET ON RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the E6D will set override lock out KEYPAD non address DIP switches for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxVRSTOFF lt CR gt zone xx VOLUME RESET OFF RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the E6D will set override lock out KEYPAD non address DIP switches for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxLKON lt CR gt zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds RESPONSE ZxxLKON lt CR gt 6 26 NUVO kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxLKOFF lt CR gt zone xx KEYPAD LOCK ON This will RESTORE ALL keypad control input on the zone useful as Parental lock control This is the same as deactivating the Parental lock control at a keypad by holding down a SOURCE key for three seconds RESPONSE ZxxLKOFF lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND VER lt CR gt Firmware version query RESPONSE NU
21. l 10 Fig 7 mii Source Link Cable Fig 8 07 amp CA AF Je De al a Zone Address WARNING y g Essentia Keypad NUVO Model NV E6DKP DC NuVo Essentia System AVIS Utiliser uniquement avec NuVo Essentia System NuVo Technologies LLC Hebron Kentucky USA www nuvotechnologies com Network CE x L Connection Local Source Use only with Data Link Cable NUVO The volume indicator LED indicates the function being set IX Keypad Zone Settings Fig 9 Each Essentia keypad has the ability to set specific zone functions These are bass and treble EQ source grouping all on party mode and volume reset Each of these functions is accessed by pressing the MUTE and SOURCE 1 5 buttons simultaneously fig 9 Press the Mute and While the keypad is in the function set mode the appropriate Y Source 1 5 buttons to source button with flash To return to normal zone control press initiate each zone the flashing source button function Source 1 Source 2 Source 3 Source 4 Source 5 EQ Control and Source Grouping Fig 10 448 44B To change bass response press the Mute button and Source 1 6 dB an button simultaneously Adjust the bass level up or down by using the Volume Up and Volume Down button
22. la chaleur incluant les amplificateurs producteurs de chaleur Ne pas n gliger la s curit que procure un branchement polaris ou avec raccordement la terre Un branchement polaris comprend deux fiches dont l une est plus large que l autre Un branchement la terre comprend deux fiches plus une troisi me reli e la terre Si la fiche secteur fournie ne s insert pas dans votre prise de courant consulter un lectricien afin de remplacer votre prise obsol te Prot ger le cordon d alimentation de tout crasement ou pincement particuli rement au niveau des fiches des r ceptacles utilis s et l endroit de sortie de l appareil Ne pas casser la fiche de terre du cordon d alimentation Utiliser uniquement les accessoires sp cifi s par le constructeur Utiliser uniquement avec le chariot de transport le support le tr pied la console ou la table sp cifi s par le constructeur ou vendus avec l appareil Lors de l utilisation d un chariot bouger avec pr caution l ensemble chariotlappareil afin d viter les dommages d un renversement D brancher cet appareil lors d orages ou s il n est pas utilis pendant une longue p riode Des pr cautions doivent tre prises afin qu aucun objet ne tombe et qu aucun liquide ne se r pande l int rieur de l appareil par les orifics de ventilation ou n importe quelle autre ouverture Pour toutes interventions techniques s adresser un technicien qualifi L intervention tech
23. larized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Do not break the ground pin of the power supply cord Only use attachments specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms or when unused for long periods of time Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation ports or any other openings Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture NUVO FRENCH
24. ng full use of the many features and capabilities of the Essentia System Package Contents E6DMS DC Main System 1 NV E6DM2 Six Source Six Zone Amplifier 6 NV E6DKP DC Decora style Zone Controller Keypads including white almond ivory and black 1 NV LRC1 Learning Remote Control 1 NV E6DEZP Decora EZ Port Multi port connection hub 1 NV NEC Network connection cable 6 NV VEC IR emitters with feedback LED 1 NV PCI IEC 3 wire power cable Zone Room 1 Zone Room 2 Zone Room 3 Zone Room 4 as KE ee Ss sav oe ss se S GA E6DXS DC Expander System 1 NV E6DMS Six Source Six Zone Amplifier 6 NV E6DKP DC Decora style Zone Controller Keypads including white almond ivory and black 1 NV LRC1 Learning Remote Control 1 NV SRC 1 Source Link Cable 1 NV DNK1 Data Link Cable 1 NV PC1 IEC 3 wire power cable Decora is a registered trademark of the Leviton Corp Zone Room 5 Zone Room 6 EZ Port Cat 5 connection 0000 De ee Ss OOo SE oe E Single Network cable connection to the Essentia Amplifier Diagram shown with optional NuVo NV P2100 auxiliary amplifier powering zone 6 Essentia D Wiring Diagram NUVO Essentia Whole Home Audio System Essentia Front Panel 1 POWER Button 2 STAND BY LED 3 Zone S
25. nique est n cessaire lorsque l appareil a t endommag de n importe quelle fa on comme par exemple si le cordon secteur ou sa fiche sont d t rior s si du liquide a coul ou si des objets sont tomb s l int rieur de l appareil si l appareil a t expos la pluie ou l humidit s il ne fonctionne pas normalement ou s il est tomb ATTENTION Pour r duire le risque d incendie ou de choc electrique ne pas exposer l appareil la pluie ou l humidit NUVO Introduction Congratulations on your purchase of the NuVo Essentia System Essentia brings the best of today s digital technology to a true whole home audio system Listening to multiple audio sources from independent zones throughout the home has never been easier or more affordable The elegant keypads allow independent selection of up to six different audio sources from up to twelve zones in the home Each ship including white almond ivory and black inserts and trim plates to match a variety of decorating choices Generation D digital amplification provides clear precise digital sound to each zone without the heat generated by traditional analog amplification The integrated infrared repeater in each keypad means you can control all of your audio sources wirelessly from any zone of your home Enjoying quality audio throughout the home is simple and affordable with Essentia This installation manual is designed to provide a sequential step by step guide to maki
26. o the same relative volume level buttons to and increase or decrease with the volume adjustment on the initiate the master keypad fig 12 Each keypad volume LED indicates a Master Mode preset meter level threshold fig 13 Source 4 Any of the other zone keypads have the ability to override the master function by selecting a new source changing a local zone s volume control or by turning a local zone s keypad off and back on The master mode is turned off by repeating the sequence of Fig 13 28 to 19 dB pressing the Mute and Source 4 buttons Do o 12 to 7 dB 78 to 55 dB A e VOLUME Volume Reset Each zone has the capability of turning on at two different volume level settings At factory default the zone will turn on at y the previous listening level If desired you can change that default to a low level volume reset regardless of the previous level To change the zone to volume reset mode press the Mute and Source 5 buttons simultaneously The Source 5 button will begin Fig 14 flashing The volume LED will first appear at the far left 9 indicating no volume reset Pushing the Volume Up button will amp ra cause the volume LED to move to the far right position This now Volume Reset Off Volume Reset On indicates that the zone is in volume reset mode fig 14 VOLUME To return to normal keypad operation press the Source 5 button again and it will stop flashing In the volume reset mod
27. oltage from up to two phone lines and two doorbell transformers When a voltage is presented to the M11 it then sends a contact closure to the Essentia System which in turn causes the system to mute momentarily This is useful in allowing the telephone ring or doorbell to be heard when audio is playing in any of the zones Fig 17 Fig 17 The Mli connects to the NuVo amplifier using a standard gt mono patch cable with a mini plug on each end Plug one end into the EXT MUTE input on the back of the amplifier and the other end into the input on the front of the Mii The back of the MI will accept up to two AC or DC voltages from two different doorbell chimes This connection is done with a two conductor wire from the terminals on the doorbell chime to the Doorbell A or Doorbell B inputs on the back of the MI1 Polarity is not important for this NV MI1 front connection NV MI1 back Up to two phone lines can be brought into the RJ 11 connection on the back of the MI The voltage from the phone ringer will trigger the NuVo System to mute NUVO XIII NV LSA40 Local Source Amplifier The LSA40 is 40 watt accessary amplifier that allows any line level audio signal local to a zone to be amplified through that zone s speakers It is designed to be used universally in a variety of applications but as shown in fig 18 it can be triggered on
28. onse as for ZxxCONSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxOFF lt CR gt Turn zone xx OFF RESPONSE Same response as for ZxxCONSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLOFF lt CR gt Turn ALL zones OFF RESPONSE ALLOFF lt CR gt This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLV lt CR gt Ramp ALL zones UP at a 10 dB second rate in 1 dB steps RESPONSE ALLV lt CR gt The ramp action will be cancelled when all zones reach MAXIMUM volume or when an ALLHLD lt CR gt Command is received Note that to stop the ramp with this command before maximum volume one reference zone must be periodically polled with a ZxxCONSR lt CR gt 24 NUVO Command to determine when the desired volume point has been reached Note that ramps in different zones may start at different levels and will all ramp at the same rate kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ALLV lt CR gt Ramp ALL zones DOWN at a 10 dB second rate in 1 dB steps RESPONSE ALLV lt CR gt The ramp action will be cancelled when all zones reach MINIMUM OFF volume or when an ALLHLD lt CR gt Command is received Note that to stop the ramp with this command before the m
29. ponse kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxSETSR lt CR gt ZoneSet STATUS REQUEST where xx is zone from 1 to 12 RESPONSE ZxxORp BASSyy TREByy GRPq VRSTu p 1 if at least one of the permanent values have been overridden by an RS232 command yy EQ level dB 12 to 0 flat to 12 in 2 dB increments if set by RS232 8 6 4 0 4 6 8 if set on keypad q 0 if SOURCE GROUP is ON 1 if SOURCE GROUP is OFF u 0 if VOLUME RESET is ON 1 if VOLUME RESET is OFF override set to 1 FOR THIS ZONE only if one of commands ZxxBASSyy lt CR gt ZxxTREByy lt CR gt or ZxxGRPq lt CR gt are issued see descriptions below Once a parameter has been SET by one of these commands it will remain UNTIL a power is cycled on the Main Unit either with the front panel power switch or by removing AC power Upon power up the system will restore keypad permanent settings see the User Manual for details on how to perform these settings b an operator manually sets one of these parameters from a keypad This takes the unit out of OVERRIDE state but other RS232 commanded settings will remain until another RS232 command overrides them or power is cycled This response is also issued whenever these parameters are set from a keypad kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxON lt CR gt Turn zone xx ON RESPONSE Same resp
30. prevent buffer overruns NUVO POWER ON STATE 1 Each zone is OFF until ON command is received 2 Each zone s ZoneSet status will be as set by the special key combination settings as detailed in the owner s manual If no keypad is connected with a given zone address then ZoneSet will default to A ORO No override B BASS 0 Bass FLAT C TREB 0 Treble FLAT D GRPO SOURCE GROUPING OFF E VRST1 VOLUME RESET TO 50 dB ON If these zone settings are overridden by the commands which follow in this document the overridden values will reset to the default values above upon cycling power on the Main Unit 3 For the first four seconds after power on a series of non control related characters will be issued at a wide range of baud rates These are necessary queries to a program that may be running on a connected PC for the purpose of Firmware field upgrades They should be ignored by the host control system NON VOLATILE COMMANDS AND ASSOCIATED RESPONSES With the exception of commands associated with setting the IR carrier frequency the effect of all commands is non permanent i e when power is cycled on the main unit it will return to default values The commands that are an exception to this rule follow in this section kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND IRSETSR lt CR gt Reads status of SOURCE IR carrier frequency settings RESPONSE IRSET aa bb cc dd ee ff lt CR gt wher
31. s The volume indicator 8 dB A 8 dB LEDs will indicate the output level fig 8 Adjust treble response VOLUME using the same process This is accessed by pressing the Mute and Source 2 buttons Once the desired setting is made press the Source button again to return the keypad to normal A operation Source grouping is a feature that allows multiple zones in an open living space to always share the same source selection but still retain individual volume and on off control This is achieved by pressing Mute and Source 3 Volume Up enables the group Piga O function and Volume Down disables the group function and causes the keypad to operate independently of all other groups A amp fig 10 Group Disabled Group Enabled VOLUME 11 NUVO All On Party Mode Fig 12 i a The lit volume LED The Essentia System has an All On feature Any keypad within the will flash when the system which can be up to twelve zones has the ability to keypad is in become a master control for the entire house The master keypad Master Mode will control zone on volume level and source selection for all other zones To place a keypad in Master Mode function simply press the Mute and Source 4 buttons simultaneously This will cause the volume indicator LED for that zone s keypad to flash continuously and adjust to a preset volume level 60 dB All L Press the Mute and Source 4 other zones will then turn on t
32. s sent over standard 16 gauge speaker wire Fig 19 LSA4o Back va Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier 16 gauge 2 conductor speaker wire is required to send voltage from the LSA40PD to four separate zones LSA40PD LSA4oPD Front AC Power Source 200 Watt AC power adapter included with the LSA40PD 17 NUVO XV NV LS112 Local Source Interrupt lower cost alternative to the LSA40 is the LS112 This is a non amplified local source interrupt It is installed in the same way the LSA40 is installed but the incoming local signal must be amplified fig 20 This is a useful accessory where a local amplified signal is already present Fig 20 The connection from the LSI12 is done with the provided two prong plug Make sure that red is positive and black is negative when splicing the two conductor wire from the LSI12 The selected zone speaker output of the Essentia or Simplese amplifier is wired directly to the LSI12 EL CONNECT TO D D D 1 pe NV ESDX SAVE USE NV SLC1 USE NV SLCt two conductor wire from a relay on the LS112 plugs into the back of the zone keypad When the Essen
33. speakers Overloading the amplifier could cause it to overheat and do damage to the output Ill Installing the NV E6DEZP EZ Port The EZ Port is a multi connection hub designed to accept all the CATS wires from the keypads in the system The location of the EZ Port should be determined by the location of the Essentia amplifier It is best to place in the wall behind the amplifier that would be easily accessible if necessary The EZ Port fits easily in any dual gang size construction bracket with an open back These are often referred to as mud rings Simply plug the terminated CATS wires into any of the sixteen available jacks on the back of the EZ Port Fig 3 The order in which the individual CATS wires are plugged is in not important although it is strongly recommended that you label the CATS with the appropriate zone number for future reference Once you have plugged the Cat 5 wires into the EZ Port screw the EZ Port into its construction bracket using the supplied mounting screws Fig 2 LEFT LEFT RIGHT RIGHT Fig 3 NUVO IV Connecting the EZ Port to the Essentia amplifier When the EZ Port is installed in the wall the only part visible should be the faceplate and a single RJ45 jack The supplied pre terminated network cable can then be plugged into the jack on the EZ Port and into the network connection on the back of the Essentia amplifier Fig 4 Any CATS cable terminated
34. tatus LED s Keypad Features 1 Volume Level 2 Power 3 Volume 4 IR Receiver 5 Mute 6 Source Selection The amplifier is designed to be turned on and remain on The power button supplies power to the system Each zone can then be turned on or off independently The amplifier should be turned on before any external connections are made This activates internal protective circuitry When lit this blue LED light emitting diode indicates that the amplifier is plugged into an AC power outlet source These LED s indicate the power status of each zone When a zone LED is lit it indicates that the zone is currently turned on Ly a The level of the zone volume is indicated by these LEDs light emitting diodes The power button turns that keypad s zone on and off independently of the other zones Pressing and holding the power button turns all zones off simultaneously Independent audio volume level for each zone is controlled with these buttons Each keypad has an IR infrared receiver located under the volume button for wireless control of the audio source equipment The mute button temporarily silences any audio playing in that keypad s zone The source buttons independently select any of the six sources connected to the Essentia amplifier The selected source button will remain lit 4 1 2 3 OUR 5 a 1 2 3 4 6 0 0 0 0 9 00 TD 4 5 6 O CONNECT TO NV E6DX
35. te of 10 dB per second in 1 dB steps This is the same as holding VOLUME UP key on a KEYPAD for 1 second RESPONSE Same response as for ZxxCONSR lt CR gt updated 10 times per second kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxVOL lt CR gt STARTS zone xx volume ramp DOWN at the rate of 10 dB per second in 1 dB steps This is the same as holding VOLUME UP key on a KEYPAD for 1 second RESPONSE Same response as for ZxxCONSR lt CR gt updated 10 times per second kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxVHLD lt CR gt STOPS zone xx volume ramp initiated by ZxxVOL lt CR gt or ZxxVOL lt CR gt commands This results in a HOLD of the level at time of command receipt RESPONSE ZxxVHLD lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxMTON lt CR gt zone xx MUTE ON mutes currently connected source RESPONSE Same response as for ZxxCONSR lt CR gt 25 NUVO kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxMTOFF lt CR gt zone xx MUTE OFF returns zone output to currently connected source at previous volume setting RESPONSE Same response as for ZxxCONSR lt CR gt kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxBASSyyy lt CR gt zone xx BASS EQ with yyy EQ le
36. tia or Simplese keypad is turned off the local source is routed to the zone speakers The Essentia or Simplese is active when the zone keypad is turned on LS112 front lt lt _ Four conductor speaker wire from the LS112 to the zone speakers Amplified signal from the local zone source Speaker input from Essentia or Simplese 18 NUVO XVI NV P2100 200 Watt Auxiliary Amplifier The P2100 is specifically designed for use with the NuVo Systems lineouts It can be used with either the fixed or variable lineouts on the Essentia with either a 1 8 3 5mm to 1 8 stereo patch cable or a 1 8 stereo to RCA patch cable Fig 21 There are two methods for triggering the P2100 from the Essentia outputs One is to set the POWER MODE switch on the P2100 to Audio the extreme left position and allow an incoming audio signal from the Essentia System to turn on the P2100 The second method is to place the POWER MODE switch in the AC DC extreme right position This will turn on the P2100 when the Essentia is on An additional feature of Essentia is zone specific triggers that will trigger the P2100 only when that zone is turned on Utilizing the voltage trigger requires a mono 1 8 3 5mm patch cable from either the System ON output on the Essentia to the P2100 Voltage trigger input or from the specific Zone Trigger on the Essentia to the Voltage Trigger on the P2100 Fig 22 RS232 Interface The RS232 port allows external
37. two way communication with the Essentia System Home automation systems such as Crestron and AMX can be set up to operate Essentia The R5232 addendum contains the necessary command sets for communication with the Essentia System 19 Fig 21 NV P2100 Amplifier CONTROL Fig 22 NV P2100 Amplifier CONTROL odBv LORS POWER VOLTAGE MODE TRIGGER INPUT LE RIGHT 330 VOLTS T 2 o o a a loworr swrrcn Aube aque ACORDE slr INPUT OUTPUT NUVO Troubleshooting Symptom When the keypad is plugged in there is a loud pop through the speakers and the keypad does not work When the keypad is plugged in it just flashes and has no functionality The amplifier is plugged in and turned on but the STAND BY LED is not lit and none of The zone is on and music is playing but the keypad only flashes when try to change source control volume mute or turn the zone off All the keypads change when a source is selected on only one With the keypads plugged in the POWER LED on the front of the amplifier will not turn on The IR repeater does not properly control the audio source equipment Probable Cause Improperly wired CATS cable Assigning duplicate addresses to multiple keypads This is most likely caused by a blown fuse on the power supply The parental lock is assigned on that particular keypad The keypads are set for Source Grouping One or more improperly wired CATS cables
38. uVo reserves the right to change specifications without notice 12V 50mA 6 zones 1 6 120VAC 240VAC 50 60Hz 340VA 290W 50VA 40W 30VA 12 5W 88 H x 430 W x 325 D 3 1 2 H x 17 W x 12 3 4 D 290 x 540 x 440 11 3 8 x 21 1 4 x 17 3 8 7 8 17 0 12 7 28 0 107 2 H x 41 5 W x 32 5 D 4 1 4 H x 15 8 W x 11 4 D NUVO Addendum Control Interface Description Document for the Nuvo E6D Main Unit Revision E for Nuvo E6D Mark II systems only June 8 2006 DB9M PORT PINOUTS Nuvo Transmit to System Controller on pin 2 Nuvo Receive from System Controller on pin 3 Ground on pin 5 SERIAL PORT PARAMETERS RS232 RTS CTS or software flow control XON XOFF NOT required 9600 baud 8N1 protocol RULES OF PROTOCOL 1 For alpha ASCII characters always use UPPER CASE In this document actual characters in a string are presented in BOLD type 2 All numerical fields are coded as ASCII digit characters 3 Each Command string is STARTED with an ASCII character and terminated by a lt CR gt character OD hexadecimal Each response string issued by the E6D will START with an ASCII and be terminated with a lt CR gt character OD hexadecimal 4 Ifa command has an error in it does not adhere to exact command syntax the E6D will respond with a lt CR gt string 5 Whenever queuing multiple commands to the E6D the host program should pause for 50 milliseconds between commands to
39. vel dB 12 to 0 flat to 12 in 2 dB increments USE LEAD 0 IN TENS PLACE FOR VALUE LESS THAN 10 RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the E6D will override the non volatile BASS setting set from keypad for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxTREByyy lt CR gt zone xx TREBLE EQ with yyy EQ level dB 12 to 0 flat to 12 in 2 dB increments USE LEAD 0 IN TENS PLACE FOR VALUE LESS THAN 10 RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the E6D will override the non volatile TREBLE setting set from keypad for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxGRPON lt CR gt zone xx SOURCE GROUP ON RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the E6D will override the non volatile GROUP setting set from keypad for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk COMMAND ZxxGRPOFF lt CR gt zone xx SOURCE GROUP OFF RESPONSE Same response as for ZxxSETSR lt CR gt NOTE sending this command to the will override the non volatile GROUP setting set from keypad for this zone until power is cycled kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
40. zzz lt CR gt ppp ON 2 characters or OFF 3 characters The remaining fields are not included in the response if ppp is OFF s SOURCE NUMBER 1 to 6 q 0 if SOURCE GROUP is ON 1if SOURCE GROUP is OFF yy level below max in dB 00 to 78 dB include lead 0 for all single digit values yy MT if in MUTE state yy XM if external MUTE is being held active zzz MST if this zone is PARTY MASTER zzz SLV if this zone is SLAVED to a PARTY MASTER in another zone zzz OFP if this zone is under LOCAL CONTROL only either there is no party master or this zone has been manually overridden This response will also be issued in response to pressing the ON OFF VOLUME or SOURCE keys on a KEYPAD NOTE the response will be issued if a SOURCE key is pressed on a zone that is powered OFF even though the key press has no effect on the system It will be output at every increment during a volume ramp initiated by HOLDING a VOLUME UP or VOLUME DOWN key on a keypad It will also be issued at every increment of a volume ramp commanded by the ZxxVOL lt CR gt and ZxxVOL lt CR gt commands see below The MUTE value will be asserted if a ZxMTON lt CR gt command has been received OR if the volume is run all the way to the lowest possible point volume off An active EXTERNAL 23 NUVO MUTE input however will always override other volume response values with the XM res
Download Pdf Manuals
Related Search
Related Contents
Quick Start Guide Manual del usuario - Honeywell Analytics Avaya Telset Administration BCM Rls 6.0 User's Manual Omnixx Copyright © All rights reserved.
Failed to retrieve file